{"id":14232,"date":"2020-07-28T21:13:57","date_gmt":"2020-07-28T21:13:57","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=14232"},"modified":"2020-07-28T21:13:57","modified_gmt":"2020-07-28T21:13:57","slug":"which-cytogenetic-technique-is-right-for-you","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/","title":{"rendered":"Which Cytogenetic Technique Is Right for You?"},"content":{"rendered":"<p><span>Cytogenetics has been part of the biological sciences since the mid-19th century, and this long history has meant that many techniques and methods are available to the modern cytogenetics researcher. This abundance of methods might make choosing one difficult, or make you wonder if all but the most cutting-edge approaches are functionally obsolete. In truth, each method has its own strengths and weaknesses, and choosing one depends on your research questions.<\/span><\/p>\n<p><span><img decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png\" \/><\/span><\/p>\n<h2><span>When to use chromosome banding techniques in cytogenetics research<\/span><\/h2>\n<p><span>Chromosome banding techniques were some of the first in cytogenetics and remain some of the most widely used. These early implementations of fluorescent imaging for chromosomes provide a surprising amount of information about chromosome structure. C-banding stains highly repetitive cytosine-rich regions, most often the centromeres where the chromosomal arms meet. Similarly, G-banding uses Giesma stain to mark heterochromatic regions, which are rarely transcribed and have a structural role in the overall chromosome. Q-banding uses quinacrine for similar results, but also fluoresces in proportion to the AT enrichment of the part of the chromosome to which it binds, providing more information. Each of these stains provides broad-scale information about chromosome structure, including gains, losses, translocations, and rearrangements. Thus, these techniques are useful for more than simply observing or counting chromosomes, and they remain valued diagnostic tools in medical settings. Many chromosomal abnormalities show clearly and distinctly with C, G or Q-banding, and research into these conditions often does not require more than that.<\/span><\/p>\n<p><span>The key limitation of chromosome banding is that these methods cannot detect aberrations below 5 megabases in size, due to resolution limitations and lack of specificity. This lack of specificity also means that conditions with highly specific etiologies and research questions that need very specific data cannot be easily answered with these techniques. These methods are also limited by user error, since they are based on largely manual processing of individual microscope images, and are vulnerable to maternal cell contamination and cell culture failure.<\/span><\/p>\n<h2><span>What is fluorescence in situ hybridization (FISH)?<\/span><\/h2>\n<p><span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/cellular-imaging\/in-situ-hybridization-ish\/fluorescence-in-situ-hybridization-fish.html\">Fluorescence in situ hybridization (FISH)<\/a> is a more tailored kind of staining. Instead of fluorescent or otherwise detectable probes binding directly to the chromosomes, probes are bound to DNA or RNA templates that then preferentially bind to their complements. This makes FISH much more specific than banding, allowing macro-scale fluorescence measurements to detect micro-scale aberrations in the chromosome. With the advent of multi-FISH, multiple fluorophores can be used in the same sample, allowing direct, in situ comparisons between differently labeled probes for multi-pronged experiments. Other variations of FISH include reverse-FISH, fiber-FISH, SKY-FISH, and more, each with its own ideal scenario.<\/span><\/p>\n<p><span>The difficulty of FISH is that probe length is a careful balancing act. A too-short probe will have frequent off-target binding that has to be distinguished from data, but a too-long probe will face difficulties binding at all, and the line between these two scenarios is not always obvious. Like banding methods, FISH requires manual microscope image review and thus suffers from the subjectivity of its practitioners, particularly when interpreting challenging signals. FISH, in its many versions, remains common for many applications and generates striking images that are ideal for press releases and magazine covers.<\/span><\/p>\n<h2><span>What is comparative genomic hybridization?<\/span><\/h2>\n<p><span>When FISH isn&rsquo;t specific enough, a related method is often the right approach: in CGH, multiple labeled DNA probes are allowed to hybridize with the sample of interest and the hybridization of each is directly compared. Typically, the probes have different labels and correspond to different versions of the same stretch of target DNA, such as different alleles or disease states. Thus, the comparison between them reveals whether the sample&rsquo;s chromosomes preferentially hybridize with one or the other. With a separate, confirmed-normal control sample, it can also detect copy-number variations and translocations, including movement of a piece of the genome from one location or chromosome to another. These are all critical parts of many genetic conditions that are difficult to properly elucidate with ordinary FISH.<\/span><\/p>\n<h2><span>When to use a microarray in cytogenetics research<\/span><\/h2>\n<p><span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-instruments.html\">Microarrays<\/a> are not a totally distinct method, but a different way to implement fluorescence-based genomics. These devices consist of microscope slides with thousands of tiny spots on which DNA or RNA probes are attached. The probes can be fluorescent or otherwise similar to the probes used in other techniques, including CGH and single-nucleotide polymorphism (SNP) probes. With so many probes concentrated onto a small surface, a sample can be tested for thousands of distinct molecular signatures in a single measurement, including single nucleotide polymorphisms (SNPs), copy-number variations, variant alleles, and more. Different kinds of probes have different ability to detect various signatures in a sample, and your experimental targets can make one kind of array (such as SNP) a better choice than another (such as CGH). For example, SNP arrays are much more effective at detecting long stretches of homozygosity and certain kinds of copy-number variations when compared to CGH arrays. Regardless of the kinds of probes used, the small size of each microarray well and of the overall device means that microarray output can be more easily and even automatically digitized than that of other cytogenetics methods, including in quantitative ways that are difficult to manage with other methods. Microarrays can also be purchased premade for various applications, providing considerable cost savings, and custom options exist for unusual applications that require carefully selected probes. For certain applications, microarrays are overkill, but their ease of use and ability to elucidate hundreds of diseases or disorders using a single technique has enabled them to become increasingly common in medical diagnostics, species identification, and other fields where being fast and easy is important.<\/span><\/p>\n<p><span>In many cases, combining methods yields the best results. Although microarrays and CGH often seem like they render all other methods irrelevant, this is far from true. Microarrays often make an ideal first test that both yields extensive data and can suggest which other tests might most effectively yield more, and this approach is recommended by the American College of Medical Genetics and American College of Obstetricians and Gynecologists. Particularly vexing samples might benefit from being viewed in multiple ways, with each set of results providing context for the other. Many groups additionally use next-generation sequencing (NGS) as part of their prenatal and\/or postnatal screening process, often as a second-round test to follow up on the results of other tests. As cytogenetics develops, even newer tools further expand the possibilities available to researchers, changing the mix of methods that best addresses every question and bringing ever more knowledge to light.<\/span><\/p>\n<p><span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/clinical\/clinical-genomics\/reproductive-health-solutions\/reproductive-health-education\/prenatal-testing-information.html\">For more information on prenatal and postnatal genetic testing, visit our education page here<\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cytogenetics has been part of the biological sciences since the mid-19th century, and this long history has meant that many techniques and methods are available to the modern cytogenetics researcher. This abundance of methods might make choosing one difficult, or make you wonder if all but the most cutting-edge approaches are functionally obsolete. In truth,<\/p>\n","protected":false},"author":120,"featured_media":14231,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172],"tags":[],"division":[],"class_list":["post-14232","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Which Cytogenetic Technique Is Right for You?<\/title>\n<meta name=\"description\" content=\"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Which Cytogenetic Technique Is Right for You?\" \/>\n<meta property=\"og:description\" content=\"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-28T21:13:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png\" \/>\n\t<meta property=\"og:image:width\" content=\"352\" \/>\n\t<meta property=\"og:image:height\" content=\"625\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"headline\":\"Which Cytogenetic Technique Is Right for You?\",\"datePublished\":\"2020-07-28T21:13:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/\"},\"wordCount\":1113,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/infographic20image20blog202.png\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/\",\"name\":\"Which Cytogenetic Technique Is Right for You?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/infographic20image20blog202.png\",\"datePublished\":\"2020-07-28T21:13:57+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"description\":\"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/infographic20image20blog202.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/infographic20image20blog202.png\",\"width\":352,\"height\":625},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/which-cytogenetic-technique-is-right-for-you\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Which Cytogenetic Technique Is Right for You?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Which Cytogenetic Technique Is Right for You?","description":"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/","og_locale":"en_US","og_type":"article","og_title":"Which Cytogenetic Technique Is Right for You?","og_description":"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-07-28T21:13:57+00:00","og_image":[{"width":352,"height":625,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","type":"image\/png"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"headline":"Which Cytogenetic Technique Is Right for You?","datePublished":"2020-07-28T21:13:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/"},"wordCount":1113,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/","name":"Which Cytogenetic Technique Is Right for You?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","datePublished":"2020-07-28T21:13:57+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"description":"Each cytogenetics method has its own strengths and weaknesses, and your choice depends on your research questions.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","width":352,"height":625},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/which-cytogenetic-technique-is-right-for-you\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Which Cytogenetic Technique Is Right for You?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png",352,625,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":2,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":14232,"position":0},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19376,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/why-most-modern-drug-candidates-fail-at-solubility\/","url_meta":{"origin":14232,"position":1},"title":"Why Most Modern Drug Candidates Fail at Solubility\u00a0","author":"Marlene Gasdia-Cochrane","date":"February 17, 2026","format":false,"excerpt":"Drug discovery capabilities continue to advance rapidly. Medicinal chemists are designing molecules with unprecedented potency and selectivity, enabling therapies that were not possible even a decade ago. Yet despite these scientific gains, many promising drug candidates still struggle to reach patients. One of the most common reasons is poor solubility.\u00a0\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Fizzing Tablet in Water","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19579,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/liquid-biopsy-cancer-research-ngs-pcr\/","url_meta":{"origin":14232,"position":2},"title":"From Discovery to Monitoring: How Sequencing and PCR Work Together in Oncology Research","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"Scientific, joins the Absolute Gene-ius podcast to discuss how molecular technologies are advancing precision oncology research. With experience spanning clinical laboratory research, digital PCR research applications, and next-generation sequencing (NGS), Dr. Sollweck shares how scientists are addressing critical unmet needs in cancer research. From liquid biopsy research strategies to minimal\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Sollweck-headshot-200x250_Jordan-Ruggieri.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":19883,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/building-a-better-sample-qc-workflow-from-extraction-to-sequencing\/","url_meta":{"origin":14232,"position":3},"title":"Building a Better Sample QC Workflow: From Extraction to Sequencing","author":"Marlene Gasdia-Cochrane","date":"August 25, 2026","format":false,"excerpt":"Article Summary Successful genomics experiments don't begin with sequencing\u2014they begin with sample quality. Every downstream application, from PCR to next-generation sequencing (NGS), depends on starting with nucleic acids that are accurately quantified and free from contaminants that could compromise results. Establishing a consistent quality control workflow helps laboratories improve reproducibility\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"A pipette drops a liquid into a petri dish with a dna sequence background, science concept. It suggests medical or genetic research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19860,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choose-sybr-green-qpcr-master-mix\/","url_meta":{"origin":14232,"position":4},"title":"Choosing the Right SYBR Green Master Mix for Your Research and Budget","author":"Behind The Bench Staff","date":"July 28, 2026","format":false,"excerpt":"Every qPCR experiment begins with a series of decisions. How many targets should you analyze? How many samples and replicates are enough? Should you expand your sample cohort or reserve budget for downstream analytical validation studies? The answers depend not only on the scientific question, but also on the resources\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"Research scientist preparing samples for a real-time PCR experiment in a molecular biology laboratory.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Blog-1280-x-720_Michealla-Scott.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Blog-1280-x-720_Michealla-Scott.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Blog-1280-x-720_Michealla-Scott.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Blog-1280-x-720_Michealla-Scott.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Blog-1280-x-720_Michealla-Scott.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":20004,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/a-guide-to-nucleic-acid-quality-control-dna-and-rna-purity\/","url_meta":{"origin":14232,"position":5},"title":"A Guide to Nucleic Acid Quality Control: DNA and RNA Purity","author":"Marlene Gasdia-Cochrane","date":"September 22, 2026","format":false,"excerpt":"Article Summary Nucleic acid quality control helps researchers evaluate DNA and RNA concentration and purity before downstream applications such as PCR, qPCR, and next-generation sequencing (NGS). A standardized workflow combining reliable extraction, concentration and purity assessment, application-appropriate quantification, and consistent laboratory practices can help identify sample issues early, improve reproducibility,\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Close-up shot of a dna sequence on a screen, a digital representation of genetic code, used for analysis.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/infographic20image20blog202.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=14232"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14232\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/14231"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=14232"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=14232"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=14232"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=14232"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}