{"id":14485,"date":"2020-09-17T22:28:43","date_gmt":"2020-09-17T22:28:43","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=14485"},"modified":"2020-09-17T22:28:43","modified_gmt":"2020-09-17T22:28:43","slug":"from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/","title":{"rendered":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks"},"content":{"rendered":"<p><span><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png\" style=\"float: right;margin: 5px\" alt=\"Paul Flynn, a bearded man in a blue shirt, discussed equine genotyping\" title=\"Paul Flynn\" width=\"500\" height=\"281\" class=\"alignright\" \/>Verifying, establishing and maintaining pedigree records for animals is an ancient practice that has had to keep up with changing technology. For Weatherbys Scientific, that means bringing cutting-edge genotyping-by-sequencing technology into this venerable field. <a href=\"https:\/\/weatherbysscientific.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Weatherbys Scientific<\/a> established the first equine studbooks for the United Kingdom and Ireland in 1791 and has maintained them for the past two and a half centuries, guiding the careful line breeding of fine horses and helping their owners know the value of their stock. As Paul Flynn, the head of research and development, describes it, Weatherbys&rsquo; role is to &ldquo;reassure integrity of pedigree verification using the technology of the time,&rdquo; and the company has embraced new developments in animal genomics technologies to always stay on the cutting edge of pedigree verification.<\/span><\/p>\n<p><span><\/span><\/p>\n<p><span>For a while, the technology of the time included blood typing, microsatellite markers and single tandem repeats (STRs). Now, the next frontier in equine pedigree verification is making the transition from STRs to <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/targeted-genotyping-sequencing.html\">genotyping by sequencing (GBS)<\/a> with single-nucleotide polymorphism (SNP) markers. &ldquo;That&rsquo;s where Weatherbys sits from a science perspective,&rdquo; he explains, &ldquo;and I&rsquo;ve been part of that journey as well.&rdquo;<\/span><\/p>\n<h2><span>From STRs to SNPs<\/span><\/h2>\n<p><span>As a 21st-century company with records going back to the 18th century, Weatherbys Scientific is &ldquo;in a very privileged position to be able to leverage the current genome assemblies that exist across various species.&rdquo; In their case, this means leveraging current equine genome assemblies in the form of <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/assembly\/GCF_002863925.1\/\" target=\"_blank\" rel=\"noopener noreferrer\">EquCab 3.0<\/a>. What Weatherbys needed was a way to verify sites and markers of interest to develop a more focused, lower-cost method for verifying equine pedigrees than whole-genome sequencing. To do this, they undertook exploratory studies using the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/550583\">Applied Biosystems<sup>TM<\/sup> Axiom 670 Equine Genotyping Array<\/a>, taking advantage of <a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/axiom-analysis-tools-enable-cutting-edge-agrigenomics-research\/\">this array&rsquo;s power<\/a> to find the most important regions of variability. These would then become the basis of their <a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-agriseq-genotyping-technology-supports-agrigenomics-research\/\">Applied Biosystems<sup>TM<\/sup> AgriSeq genotyping-by-sequencing panel<\/a>, a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A34144#\/A34144\">far lower-cost tool<\/a> that offers<\/span><span> the information they need in a well-organized and focused form. Armed with this more focused tool, Weatherbys Scientific is well-positioned to remain an industry leader in equine studbook maintenance and pedigree analysis.<\/span><\/p>\n<p><span>For more information abou<\/span><span>t <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/agriseq-targeted-genotyping-sequencing.html\">AgriSeq gene panels<\/a> and other companion animal research products, <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/agrigenomics-solutions-companion-animals.html.html\">click here<\/a>. To contact us regarding AgriSeq products, <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/global\/forms\/industrial\/agrigenomics-contact-request.html\">click here<\/a>. For Thermo Fisher Scientific&rsquo;s agrigenomics brochure, <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/GSD\/brochures\/agrigenomics-brochure.pdf\">click here<\/a>.<\/span><\/p>\n<p><span>For research use only. Not for use in diagnostic procedures.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Verifying, establishing and maintaining pedigree records for animals is an ancient practice that has had to keep up with changing technology. For Weatherbys Scientific, that means bringing cutting-edge genotyping-by-sequencing technology into this venerable field. Weatherbys Scientific established the first equine studbooks for the United Kingdom and Ireland in 1791 and has maintained them for the<\/p>\n","protected":false},"author":120,"featured_media":14484,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172],"tags":[],"division":[],"class_list":["post-14485","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks<\/title>\n<meta name=\"description\" content=\"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks\" \/>\n<meta property=\"og:description\" content=\"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-17T22:28:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"449\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"headline\":\"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks\",\"datePublished\":\"2020-09-17T22:28:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/\"},\"wordCount\":416,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/09\\\/paul20flynn.png\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/\",\"name\":\"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/09\\\/paul20flynn.png\",\"datePublished\":\"2020-09-17T22:28:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"description\":\"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/09\\\/paul20flynn.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/09\\\/paul20flynn.png\",\"width\":800,\"height\":449,\"caption\":\"Paul Flynn, a bearded man in a blue shirt, discussed equine genotyping\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks","description":"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/","og_locale":"en_US","og_type":"article","og_title":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks","og_description":"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-09-17T22:28:43+00:00","og_image":[{"width":800,"height":449,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","type":"image\/png"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"headline":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks","datePublished":"2020-09-17T22:28:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/"},"wordCount":416,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/","name":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","datePublished":"2020-09-17T22:28:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"description":"Verifying, establishing and maintaining pedigree records for animals is an ancient practice that now requires cutting-edge genotyping-by-sequencing technology.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","width":800,"height":449,"caption":"Paul Flynn, a bearded man in a blue shirt, discussed equine genotyping"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/from-strs-to-snps-the-evolution-of-genotyping-for-equine-studbooks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"From STRs to SNPs: The Evolution of Genotyping for Equine Studbooks"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png",760,427,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19640,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/direct-from-lysate-snp-genotyping-in-research-applications\/","url_meta":{"origin":14485,"position":0},"title":"Direct-from-Lysate SNP Genotyping in Research Applications","author":"Ashleigh Barlow","date":"April 6, 2026","format":false,"excerpt":"Direct-from-lysate workflow enabled by DNA Extract All Reagents compared to traditional DNA purification for SNP genotyping applications. Can You Perform SNP Genotyping Without DNA Purification? The short answer: In many research workflows, direct-from-lysate SNP genotyping can be performed without traditional DNA purification\u2014when appropriate chemistries and verification procedures are used. Direct-from-lysate\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Comparison of traditional DNA purification workflow and direct-from-lysate workflow using DNA Extract All Reagents for SNP genotyping prior to qPCR.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19976,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/taqman-assay-design-genomic-data\/","url_meta":{"origin":14485,"position":1},"title":"What does it take to keep 20 million Applied Biosystems TaqMan Assays current?","author":"Ashleigh Barlow","date":"September 30, 2026","format":false,"excerpt":"How do you keep more than 20 million TaqMan assays current as genomic knowledge evolves? Every year, our understanding of biology becomes more complete. New variants are discovered, transcript annotations improve, gene models evolve, and our assay-design algorithms advance. That does not mean an assay designed years ago is suddenly\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19966,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-assay-optimization-qpcr\/","url_meta":{"origin":14485,"position":2},"title":"Building Better Multiplex Panels: Identifying Assay Interactions Early","author":"Ashleigh Barlow","date":"September 8, 2026","format":false,"excerpt":"Multiplex qPCR has transformed molecular research by enabling scientists to detect multiple targets in a single reaction. The benefits are clear: reduced sample consumption, lower costs, faster workflows, and more data from every experiment. However, designing successful multiplex assays isn't always straightforward. Traditionally, identifying problematic assay combinations required extensive wet-lab\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"For Research Use Only. Not for use in diagnostic procedures. \u00a9 2026 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19650,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/history-of-qpcr-30-years\/","url_meta":{"origin":14485,"position":3},"title":"qPCR at 30: Advancing Science Together, from Insight to Impact","author":"Behind The Bench Staff","date":"April 7, 2026","format":false,"excerpt":"Celebrating 30 years of qPCR innovation and the scientific partnerships that continue to drive discovery forward. Thirty years ago, a simple but groundbreaking question changed molecular biology: What if DNA amplification could be measured in real time? The answer became quantitative PCR (qPCR), a technology that allows scientists to monitor\u2026","rel":"","context":"In &quot;Perspectives&quot;","block_context":{"text":"Perspectives","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/perspectives\/"},"img":{"alt_text":"Mosaic image of a scientist composed of smaller images representing qPCR technology, instruments, and scientific research advancements.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":14485,"position":4},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19997,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ai-laboratory-automation-qpcr\/","url_meta":{"origin":14485,"position":5},"title":"AI and Laboratory Automation: The experimental context behind qPCR data","author":"Behind The Bench Staff","date":"September 11, 2026","format":false,"excerpt":"AI is changing how researchers analyze biological data, while automation is changing how that data is performed at scale. As more of the research process becomes automated and data-driven, an important question emerges: What should researchers consider about how data is generated before downstream analysis begins? In qPCR, assays, reagents,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"qPCR reaction tube with amplification curves representing experimental data used in AI and laboratory automation.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/09\/paul20flynn.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14485","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=14485"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14485\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/14484"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=14485"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=14485"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=14485"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=14485"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}