{"id":16025,"date":"2022-01-12T16:48:21","date_gmt":"2022-01-12T16:48:21","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=16025"},"modified":"2025-03-12T19:09:14","modified_gmt":"2025-03-12T19:09:14","slug":"targeted-gene-editing-crispr-technology-fight-hiv","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/","title":{"rendered":"Targeted Gene Editing with CRISPR Technology"},"content":{"rendered":"<h2>Combating Life-Threatening Viral Infections \u2013 HIV-1<\/h2>\n<h3>Using CRISPR and Cas Protein to Identify and Edit DNA Sequences<\/h3>\n<p>CRISPR technology is a revolutionary gene editing tool that holds great promise for combating life-threatening viral infections. CRISPR stands for clustered regularly interspaced short palindromic repeats, which are part of a genome editing system that evolved naturally in bacteria [1,2]. Geneticists can use CRISPR technology to recognize a specific DNA sequence and edit it with a CRISPR-associated ribonuclease, or Cas protein.<\/p>\n<p>To direct editing specificity, the Cas protein is complexed with a small guide RNA (gRNA) that is complementary to the target sequence. The Cas protein cuts both DNA strands when the associated gRNA binds to the target sequence, and innate cellular DNA repair mechanisms can be harnessed to introduce a nucleotide-specific change, remove an entire DNA segment, or replace region of DNA with a customized sequence. Sanger sequencing by capillary electrophoresis (CE) is typically performed afterwards to assess the accuracy and efficiency of the gene editing process.<\/p>\n<h2>CRISPR Gene Editing as a Novel Approach to Durable HIV-1 Control<\/h2>\n<p>Approximately 38 million people around the world live with human immunodeficiency virus (HIV), and up to one million individuals die of illness due to acquired immunodeficiency syndrome (AIDS) each year [3]. While antiretroviral therapy (ART) can significantly inhibit HIV-1 replication, it does not remove proviral HIV-1 DNA from the host genome. The latent virus persists in host cells and can readily reactivate if ART is discontinued, which can result in progression to AIDS. Long-term remission of HIV-1 infection is exceedingly rare [4,5], and there is currently no cure for AIDS.<img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-225 size-full\" title=\"CRISPR-Cas9 Targeted Gene Editing to Identify and Edit DNA Sequences\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/sangeredu2.jpg\" alt=\"Strand of DNA\" width=\"250\" height=\"200\" \/><\/p>\n<h2>HIV-1 Therapy with the CRISPR-Cas9 System<\/h2>\n<p>Cas9 is an RNA-guided endonuclease originally discovered in <em>Streptococcus pyogenes<\/em>, and gene editing with the CRISPR-Cas9 system has demonstrated potential as a way to eliminate the need for ART to treat HIV-1 infection in humans [6,7]. Researchers in the <a title=\"Pillai Laboratory - University of California San Francisco\" href=\"https:\/\/pillailab.ucsf.edu\/antiretroviral-gene-therapy\" target=\"_blank\" rel=\"noopener\">Pillai laboratory at the University of California San Francisco<\/a>, the <a title=\"Vitalant Research Institute\" href=\"https:\/\/research.vitalant.org\" target=\"_blank\" rel=\"noopener\">Vitalant Research Institute<\/a>, and Los Alamos National Laboratory devised a dual-target editing strategy to prevent HIV-1 replication in human T cells and counteract infection of uninfected cells <em>in vitro<\/em>.<\/p>\n<p><strong>Related<\/strong>: <a title=\"Genotyping of HIV-1 to Detect Drug Resistance\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/genotyping-hiv-detect-drug-resistance.html\" target=\"_blank\" rel=\"noopener\">Genotyping of HIV-1 to Detect Drug Resistance<\/a><\/p>\n<p>Human Jurkat cells infected with HIV-1 were transfected with a lentiviral vector that expressed the <em>Staphylococcus aureus<\/em> Cas9 enzyme SaCas9 and two gRNAs that targeted highly conserved regions in the latent HIV-1 <em>gag<\/em> gene. The team designed gRNAs for highly conserved regions of the HIV genome to maximize the number of strains they could target and minimize the likelihood of off-target editing events. The lentiviral vector was also engineered to express a gRNA that recognized a sequence in the human <em>CXCR4<\/em> gene to reduce expression of the CXCR4 receptor responsible for HIV-1 entry into CD4<sup>+<\/sup> T cells.<\/p>\n<p>Prior to gene editing, the team performed PCR to amplify genomic regions that contained gRNA target sequences and analyzed the amplicons with high-resolution Sanger sequencing. They screened a total of 20 gRNA candidates to identify gRNAs that would be both effective and unlikely to cause off-target editing events. Once CRISPR-Cas9 editing was complete, Sanger sequencing was performed again to determine whether the dual-target strategy was successful. The Sanger sequencing output was used as input for tracking of indels by decomposition (TIDE) analysis, which revealed the frequency of small insertions and deletions (indels) generated by the CRISPR-Cas9 system.<\/p>\n<h2>CRISPR-Cas9 System<\/h2>\n<h3>Reduce Virus Production and Achieve Remission<\/h3>\n<p>Targeting the HIV-1 <em>gag<\/em> gene alone reduced virus production by 78%, while targeting only the human <em>CXCR4<\/em> gene reduced surface expression of the CXCR4 receptor by 35%. The team found that targeting the <em>gag<\/em> and <em>CXCR4<\/em> genes simultaneously was the most effective strategy for achieving remission. The complete CRISPR-Cas9 system both inactivated HIV-1 production in infected human T cells and rendered uninfected cells resistant to the virus. The team also developed a mathematical model that predicted the two-pronged editing approach would enable 513 days of remission <em>in vivo<\/em> in the absence of ART and 591 days of remission after ART cessation.<\/p>\n<h3>Indefinite Remission Might Be Possible<\/h3>\n<p>The authors of the study concluded that indefinite remission might be possible with multiple rounds of CRISPR-Cas9 gene therapy. Their work demonstrates that a dual-gene CRISPR-Cas9 editing strategy has the potential to revolutionize clinical HIV-1 management by eliminating the need for antiretroviral drugs.<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-16027 alignright\" title=\"Targeted Gene Editing with CRISPR Technology and Sanger Sequencing Gene Editing Confirmation\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-300x200.jpg\" alt=\"colleagues at computer together exploring possibilities\" width=\"300\" height=\"200\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-1024x683.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-1536x1024.jpg 1536w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-96x65.jpg 96w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg 1773w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2>Sanger Sequencing by CE and Fragment Analysis<\/h2>\n<h3>The Gold Standard For Gene Editing Confirmation<\/h3>\n<h4>Accurate, Simple, Cost-Effective, Long Read Lengths<\/h4>\n<p>Sanger sequencing by capillary electrophoresis (CE) is the gold standard for gene editing confirmation due to its accuracy, simplicity, cost-effectiveness, and long read lengths. Sanger sequence analysis is straightforward.<\/p>\n<h3>Assess Editing Efficiency with Fragment Analysis by CE<\/h3>\n<p>In addition, fragment analysis by CE enables rapid detection of insertions and deletions with single base pair resolution. Since DNA repair during CRISPR-mediated gene editing in primary transformed cells is not entirely efficient or accurate, fragment analysis and Sanger sequencing are often performed to assess editing efficiency. CE is also useful for determining the frequency of successful editing events in secondary clones.<\/p>\n<p><strong>Related<\/strong>: <a title=\"CRISPR Gene Editing Confirmation with Sanger Sequencing\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/crispr-talen-genome-editing-sanger-sequencing.html\" target=\"_blank\" rel=\"noopener\">CRISPR Gene Editing Confirmation With Sanger Sequencing<\/a><\/p>\n<p><a title=\"Instruments for Sanger Sequencing and Fragment Analysis by Capillary Electrophoresis\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html\" target=\"_blank\" rel=\"noopener\">Applied Biosystems<sup>\u2122<\/sup> genetic analyzers<\/a> are trusted CE systems for <a title=\"Sanger Sequencing and Fragment Analysis by Capillary Electrophoresis\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html\" target=\"_blank\" rel=\"noopener\">Sanger sequencing and fragment analysis<\/a>, and they drive today\u2019s most powerful CRISPR gene editing applications. Innovations like the <a title=\"About the SeqScreener Gene Edit Confirmation App on Thermo Fisher Connect\" href=\"https:\/\/apps.thermofisher.com\/apps\/help\/MAN0019454\/GUID-13CF6DAF-343B-4969-9459-E910C7B01B43.html\" target=\"_blank\" rel=\"noopener\">SeqScreener app<\/a> on the <a title=\"Thermo Fisher Connect Platform - A Comprehensive Platform Enabling Your Innovative Ideas\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/digital-science\/thermo-fisher-connect.html\" target=\"_blank\" rel=\"noopener\">Thermo Fisher<sup>\u2122<\/sup> Connect Platform<\/a> have been designed from the ground up for determining the range and frequency of CRISPR-Cas9 gene edits.<\/p>\n<p><strong>Related<\/strong>: <a title=\"Your Vital Research Data is Secure with Thermo Fisher Connect\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/trust-thermo-fisher-connect-to-keep-your-data-secure\/\" target=\"_blank\" rel=\"noopener\">Your Vital Research Data is Secure with Thermo Fisher Connect<\/a><\/p>\n<p><strong>Learn More<\/strong>: <a title=\"CRISPR Gene Editing Confirmation with Sanger Sequencing - SeqScreener\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/crispr-talen-genome-editing-sanger-sequencing.html\" target=\"_blank\" rel=\"noopener\"><strong>thermofisher.com\/seqscreener<\/strong> &#8211; Sanger sequencing and fragment analysis for CRISPR-Cas9 gene editing confirmation and Applied Biosystems genetic analyzers<\/a>.<\/p>\n<p>Check out more posts like this one on our <a title=\"Behind the Bench\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/\" target=\"_blank\" rel=\"noopener\">Behind the Bench blog<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<h2>References<\/h2>\n<p>&nbsp;<\/p>\n<ol>\n<li>Jansen R, van Embden JDA, Gaastra W, Schouls LM (2002) Identification of genes that are associated with DNA repeats in prokaryotes. <em>Mol Microbiol<\/em> 43(6):1565-1575.<\/li>\n<li>Andersson AF and Banfield JF (2008) Virus population dynamics and acquired virus resistance in natural microbial communities. <em>Science<\/em> 320(5879):1047-1050.<\/li>\n<li>Joint United Nations Program on HIV\/AIDS (2020) Global HIV and AIDS statistics\u2014fact sheet (https:\/\/www.unaids.org\/en\/resources\/fact-sheet).<\/li>\n<li>Hutter G, Nowak D, Mossner M et al. (2009) Long-term control of HIV by CCR5 Delta32\/Delta32 stem cell transplantation. <em>New Engl J Med<\/em> 360:692-698.<\/li>\n<li>Gupta RK, Abdul-Jawad S, McCoy LE et al. (2019) HIV-1 remission following CCR5\u220632\/\u220632 haematopoietic stem cell transplantation. <em>Nature<\/em> 568:244-248.<\/li>\n<li>Chavez LR, Reddy, NR, Raymond KA et al. (2020) Durable control of HIV-1 using a <em>Staphylococcus aureus<\/em> Cas9-expressing lentivirus co-targeting viral latency and host susceptibility. bioR\u03c7i\u03bd preprint (https:\/\/doi.org\/10.1101\/2020.08.10.243329).<\/li>\n<li>Xu L, Wang J, Liu Y et al. (2019) CRISPR-edited stem cells in a patient with HIV and acute lymphocytic leukemia. <em>New Engl J Med<\/em> 381:1240-1247).<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Combating Life-Threatening Viral Infections \u2013 HIV-1 Using CRISPR and Cas Protein to Identify and Edit DNA Sequences CRISPR technology is a revolutionary gene editing tool that holds great promise for combating life-threatening viral infections. CRISPR stands for clustered regularly interspaced short palindromic repeats, which are part of a genome editing system that evolved naturally in<\/p>\n","protected":false},"author":120,"featured_media":16027,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[67],"tags":[126,127,109,25],"division":[],"class_list":{"0":"post-16025","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-infectious-diseases","8":"tag-crispr-cas9","9":"tag-gene-editing","10":"tag-sanger-ce","11":"tag-sanger-sequencing","12":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Targeted Gene Editing with CRISPR-Cas9 &amp; Sanger Sequencing<\/title>\n<meta name=\"description\" content=\"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Targeted Gene Editing with CRISPR Technology\" \/>\n<meta property=\"og:description\" content=\"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-12T16:48:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-12T19:09:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1773\" \/>\n\t<meta property=\"og:image:height\" content=\"1182\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Targeted Gene Editing with CRISPR Technology\",\"datePublished\":\"2022-01-12T16:48:21+00:00\",\"dateModified\":\"2025-03-12T19:09:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/\"},\"wordCount\":1092,\"commentCount\":28,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg\",\"keywords\":[\"CRISPR-Cas9\",\"Gene Editing\",\"Sanger - CE\",\"Sanger Sequencing\"],\"articleSection\":[\"Infectious Diseases\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/\",\"name\":\"Targeted Gene Editing with CRISPR-Cas9 & Sanger Sequencing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg\",\"datePublished\":\"2022-01-12T16:48:21+00:00\",\"dateModified\":\"2025-03-12T19:09:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg\",\"width\":1773,\"height\":1182,\"caption\":\"colleagues at computer together exploring possibilities\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/targeted-gene-editing-crispr-technology-fight-hiv\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Targeted Gene Editing with CRISPR Technology\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Targeted Gene Editing with CRISPR-Cas9 & Sanger Sequencing","description":"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/","og_locale":"en_US","og_type":"article","og_title":"Targeted Gene Editing with CRISPR Technology","og_description":"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-01-12T16:48:21+00:00","article_modified_time":"2025-03-12T19:09:14+00:00","og_image":[{"width":1773,"height":1182,"url":"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Targeted Gene Editing with CRISPR Technology","datePublished":"2022-01-12T16:48:21+00:00","dateModified":"2025-03-12T19:09:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/"},"wordCount":1092,"commentCount":28,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","keywords":["CRISPR-Cas9","Gene Editing","Sanger - CE","Sanger Sequencing"],"articleSection":["Infectious Diseases"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/","name":"Targeted Gene Editing with CRISPR-Cas9 & Sanger Sequencing","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","datePublished":"2022-01-12T16:48:21+00:00","dateModified":"2025-03-12T19:09:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Combating life-threatening viral infections like HIV-1 using CRISPR-Cas9 targeted gene editing and Sanger Sequencing gene editing confirmation.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","width":1773,"height":1182,"caption":"colleagues at computer together exploring possibilities"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/targeted-gene-editing-crispr-technology-fight-hiv\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Targeted Gene Editing with CRISPR Technology"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":67,"label":"Infectious Diseases"}],"post_tag":[{"value":126,"label":"CRISPR-Cas9"},{"value":127,"label":"Gene Editing"},{"value":109,"label":"Sanger - CE"},{"value":25,"label":"Sanger Sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1-1024x683.jpg",760,507,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":38,"category_info":[{"term_id":67,"name":"Infectious Diseases","slug":"infectious-diseases","term_group":0,"term_taxonomy_id":67,"taxonomy":"category","description":"","parent":0,"count":82,"filter":"raw","meta":[],"cat_ID":67,"category_count":82,"category_description":"","cat_name":"Infectious Diseases","category_nicename":"infectious-diseases","category_parent":0}],"tag_info":[{"term_id":126,"name":"CRISPR-Cas9","slug":"crispr-cas9","term_group":0,"term_taxonomy_id":126,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":127,"name":"Gene Editing","slug":"gene-editing","term_group":0,"term_taxonomy_id":127,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":109,"name":"Sanger - CE","slug":"sanger-ce","term_group":0,"term_taxonomy_id":109,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":16025,"position":0},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":16025,"position":1},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19645,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/aav-viral-vector-analytics-cdmo\/","url_meta":{"origin":16025,"position":2},"title":"Almost a Virus: How CDMOs Enable Scalable Cell and Gene Therapy","author":"Behind The Bench Staff","date":"April 6, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, Dr. Dan Mitchell, Senior Director of Analytical Development and Quality Control at Matica Biotechnology, explains how contract development and manufacturing organizations (CDMOs) support the advancement of cell and gene therapies. The discussion focuses on viral vector development, analytical strategies, and the technologies used to\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Headshot of a man with dark hair and a beard wearing a suit and tie against a neutral background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":16025,"position":3},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19176,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tackling-insoluble-and-difficult-to-express-transmembrane-proteins\/","url_meta":{"origin":16025,"position":4},"title":"Tackling Insoluble and Difficult-to-Express Proteins","author":"Behind The Bench Staff","date":"October 23, 2025","format":false,"excerpt":"Few things in the lab can feel as challenging as working with transmembrane proteins. These complex structures span cell membranes, performing vital functions from signal transduction to transport of molecules across cellular barriers. Low expression yields, protein misfolding, and aggregation frequently plague researchers attempting to produce functional transmembrane proteins. Extracting\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"The complex structure and environment of transmembrane proteins within the lipid bilayer.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/trans_membrane_pex.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/trans_membrane_pex.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/trans_membrane_pex.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/trans_membrane_pex.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":16025,"position":5},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/colleagues-at-computer-together-exploring-possibilities-1773x1182-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=16025"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16025\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/16027"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=16025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=16025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=16025"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=16025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}