{"id":16081,"date":"2022-01-27T19:22:31","date_gmt":"2022-01-27T19:22:31","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=16081"},"modified":"2022-01-27T20:13:17","modified_gmt":"2022-01-27T20:13:17","slug":"tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/","title":{"rendered":"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)"},"content":{"rendered":"<h2>Why Selective Dry Cow Therapy (SDCT)?<\/h2>\n<h3>Keep Mastitis and Somatic Cell Count (SCC) Low<\/h3>\n<p>Dairy farms around the world are shifting to selective dry cow therapy (SDCT) to improve the judicious use of antibiotics without compromising cow health or welfare. Mathijs Bakker, dairy veterinarian and consultant based in the Netherlands, has worked with many dairy farmers who have made the switch, and experience has told him that farmers can\u2019t continue using the same blanket treatment protocols \u2013 even if it takes a higher level of management to keep mastitis and somatic cell count (SCC) levels low with SDCT.<\/p>\n<h2>Challenges of Selective Dry Cow Therapy<\/h2>\n<h3>Important Factors for Success<\/h3>\n<h4>Amount of Milk, Feed Rations, Separation Groups<\/h4>\n<p>&#8220;First, you have to reduce the amount of milk. In the Netherlands, we used to dry off cows at 20 liters (44 pounds) per day, and now we are advising farmers to dry off cows at 10 liters (22 pounds) per day,&#8221; he said. &#8220;Farmers need to change dry-off cows&#8217; feed ration and move them to another group, particularly when working with a robotic milking system. It&#8217;s more labor and time to get dry-off cows from the robot to the separation group and, once a day, back to the robot. If a farmer isn\u2019t willing to do this, SDCT can be a mess.&#8221;<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-380 alignright\" title=\"SDCT Important Factors for Success\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Cows-eating-300x200.jpg\" alt=\"Cows eating\" width=\"300\" height=\"200\" \/><\/p>\n<h4>Clean, Dry Bedding<\/h4>\n<p>Another important dry-off factor that farmers should consider is a cow\u2019s bedding. Clean, dry bedding is extremely important to the success of the program, because bedding can act as a reservoir for some mastitis pathogens. Thus, replacing bedding often and reconsidering the source of bedding may also reduce bedding bacteria count. Farmers should work with their veterinarian to determine the best bedding source for their farm.<\/p>\n<h4>Internal Teat Sealant to Prevent Infections<\/h4>\n<h5>Employee training to follow proper intramammary infusion technique.<\/h5>\n<p>Then, at the time of dry-off, farmers should use an internal teat sealant in all quarters to ensure cows don&#8217;t pick up an infection. Failure to follow a proper intramammary infusion technique can result in the introduction of mastitis pathogens to the udder. Well-trained employees are also crucial to the process and its success, so prior to dry-off is an optimal time for a veterinarian to visit and retrain the farm staff.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-16084 alignright\" title=\"The Importance of Checking Cows Udders Daily After Dry-Off\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-300x169.jpg\" alt=\"medium close up of dairy cow udders\" width=\"300\" height=\"169\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-1024x575.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-768x432.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-1536x863.jpg 1536w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cow-udder-Unsplash-2048x1151.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h4>Post-Dry-Off Monitoring<\/h4>\n<p>Another point that Bakker makes is the importance of checking cows&#8217; udders daily to feel if they are swollen or feverish and hot to the touch after dry-off.<\/p>\n<p>&#8220;For several weeks post-dry-off, it\u2019s important that farmers touch the udder, so they can feel if the udder is hot or swollen,&#8221; Bakker noted. &#8220;Also, check to see if dry-off cows are active\u2014getting up to go to the feed bunk and to get water. You want to make sure they are active and functioning as you\u2019d expect. If they are not, it may be a sign of infection. The first week after dry-off is most important.&#8221;<\/p>\n<h2>Proven Efficacy of SDCT<\/h2>\n<p>A 2021 systematic review and meta-analysis investigating the efficacy of SDCT compared to blanket dry cow therapy showed that SDCT &#8220;reduced the use of antimicrobials at dry-off without any negative effect on udder health or milk production during the first months of the subsequent lactation, if, and only if, internal teat sealants are used for healthy, untreated quarters per cow.&#8221; Also, SDCT reduced the use of antibiotics at dry-off by 66%.<sup>1<\/sup><\/p>\n<h2>Importance of Diagnostic Testing for Successful SDCT Programs<\/h2>\n<p>Diagnostic testing and monitoring are essential to implementing a SDCT program. In Europe where SDCT is or is soon becoming regulated in many countries, milk from an infected cow is tested to determine if the mastitis is caused by a gram positive or gram negative bacteria. Diagnostic testing such as real-time PCR is a quick and effective way to identify the mastitis-causing pathogen, along with whether it is gram positive or negative, in order to properly treat the infection.<\/p>\n<h3>Standardization of SDCT Protocols<\/h3>\n<p>In the Netherlands, the protocol for SDCT is the same on every farm:<\/p>\n<ol>\n<li>Producers start with individual somatic cell count (SCC) from data collected by DHI (Dairy Herd Improvement) sampling for cows that are ready to dry off.<\/li>\n<li>For cows, antibiotics can be used if an individual SCC is above 50,000. For heifers, the threshold for a SCC is 150,000. Cows under those thresholds are not eligible to receive any antibiotic therapy; a teat sealant can be applied at dry off.<\/li>\n<li>If eligible for antibiotics, producers determine the antibiotic that is prudent to use:<\/li>\n<li>First choice\u2014can be used &#8220;empirically,&#8221; e.g., before it is known which bacteria are causing the infection and without carrying out sensitivity testing<\/li>\n<li>Second choice\u2014can only be used if sensitivity testing (e.g., diagnostic testing with real-time PCR to see whether the bacteria are resistant to certain antibiotics) shows that first-choice antibiotics would be unlikely to work<\/li>\n<li>Third choice\u2014can only be used if sensitivity testing shows that neither first- nor second-choice antibiotics would work<\/li>\n<\/ol>\n<p><strong>Related<\/strong>: <a title=\" Diagnostics Role in Selective Dry Cow Therapy\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnostics-role-in-selective-dry-cow-therapy\/\">\u00a0Selective Dry Cow Therapy Protocols and Diagnostics<\/a><\/p>\n<h2>Real-Time PCR Diagnostics for Herd Health<\/h2>\n<p>&#8220;As a veterinarian, if I must make the choice between first- and second-choice dry-off therapy, it&#8217;s always problem driven. If the cure rate is very low, then we must dive into it and determine what\u2019s going on with that cow or the herd,&#8221; he said. &#8220;I always start with real-time PCR, just to make sure I know if it&#8217;s a gram-negative or gram-positive problem, and after that, I go to the antibiotic susceptibility test.&#8221;<\/p>\n<h3>Real-Time PCR to Monitor SCC Levels &amp; Diagnose Mastitis<\/h3>\n<h4>Speed is Key<\/h4>\n<p>Speed is a key benefit with PCR because results are often available the same day. This is especially true for Bakker because he\u2019s performing the PCR tests in his own lab. He also likes to deliver the results directly to his client. Diagnostic testing is also needed to monitor clinical mastitis and SCCs during lactation, but it\u2019s especially important in early lactation.<\/p>\n<p><strong>Related<\/strong>: <a title=\"Diagnostics Role in Selective Dry Cow Therapy\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosing-bovine-mastitis-real-time-pcr-for-fast-results\/\">Diagnosing Bovine Mastitis: Real-Time PCR for Fast Results<\/a><\/p>\n<p>\u2013 \u2013<\/p>\n<p><strong>See these related articles about Real-Time PCR and Bovine Herd Health<\/strong>:<\/p>\n<ul>\n<li><a title=\"Protect Herd Health and Productivity With Real-Time PCR - Bovine Mastitis Diagnostics\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/protect-herd-health-and-productivity-with-pcr\/\">Protect Herd Health and Productivity With Real-Time PCR<\/a><\/li>\n<li><a title=\"The Importance of Sensitivity and Specificity in Diagnosing Bovine Mastitis\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/the-importance-of-sensitivity-and-specificity-in-diagnosing-bovine-mastitis\/\">The Importance of Sensitivity and Specificity in Diagnosing Bovine Mastitis<\/a><\/li>\n<li style=\"list-style-type: none\"><\/li>\n<li><a title=\"Diagnostic Solutions for Dairy Cattle \u2013 Bovine Disease Diagnostic Resources for Veterinarians and Farmers\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/products-and-services\/promotions\/industrial\/diagnostic-solutions-dairy-cattle.html\">Diagnostic Solutions for Dairy Cattle<\/a><\/li>\n<\/ul>\n<p>Learn more at <strong><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/animal-health\/bovine-cattle-diagnostic-solutions\/bovine-diseases\/bovine-mastitis.html\">thermofisher.com\/mastitis<\/a><\/strong><\/p>\n<p>\u2013 \u2013<\/p>\n<h2>References<\/h2>\n<p>&nbsp;<\/p>\n<p>1 Kabera, Fid\u00e8le et al. (2021) Comparing blanket vs. selective dry cow treatment approaches for elimination and prevention of intramammary infections during the dry period: a systematic review and meta-analysis. Front. Vet. Sci. 8:688450. Frontiers Media SA, doi:10.3389\/fvets.2021.688450.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Why Selective Dry Cow Therapy (SDCT)? Keep Mastitis and Somatic Cell Count (SCC) Low Dairy farms around the world are shifting to selective dry cow therapy (SDCT) to improve the judicious use of antibiotics without compromising cow health or welfare. Mathijs Bakker, dairy veterinarian and consultant based in the Netherlands, has worked with many dairy<\/p>\n","protected":false},"author":120,"featured_media":16113,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[83,172],"tags":[2232,46,2241],"division":[],"class_list":{"0":"post-16081","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-animal-health-and-agrigenomics","8":"category-general","9":"tag-bovine-mastitis","10":"tag-real-time-pcr","11":"tag-sdct","12":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Why Selective Dry Cow Therapy? Tips for a Successful Dry-Off<\/title>\n<meta name=\"description\" content=\"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols &amp; PCR diagnostics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)\" \/>\n<meta property=\"og:description\" content=\"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols &amp; PCR diagnostics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-27T19:22:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-27T20:13:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)\",\"datePublished\":\"2022-01-27T19:22:31+00:00\",\"dateModified\":\"2022-01-27T20:13:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/\"},\"wordCount\":1081,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/cows-eating-1024x683-1.jpg\",\"keywords\":[\"bovine mastitis\",\"Real Time PCR\",\"SDCT\"],\"articleSection\":[\"Animal Health and AgriGenomics\",\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/\",\"name\":\"Why Selective Dry Cow Therapy? Tips for a Successful Dry-Off\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/cows-eating-1024x683-1.jpg\",\"datePublished\":\"2022-01-27T19:22:31+00:00\",\"dateModified\":\"2022-01-27T20:13:17+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols & PCR diagnostics.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/cows-eating-1024x683-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/01\\\/cows-eating-1024x683-1.jpg\",\"width\":1024,\"height\":683,\"caption\":\"Cows eating, lined up in an open-air stable.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Why Selective Dry Cow Therapy? Tips for a Successful Dry-Off","description":"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols & PCR diagnostics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/","og_locale":"en_US","og_type":"article","og_title":"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)","og_description":"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols & PCR diagnostics.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-01-27T19:22:31+00:00","article_modified_time":"2022-01-27T20:13:17+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)","datePublished":"2022-01-27T19:22:31+00:00","dateModified":"2022-01-27T20:13:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/"},"wordCount":1081,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","keywords":["bovine mastitis","Real Time PCR","SDCT"],"articleSection":["Animal Health and AgriGenomics","General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/","name":"Why Selective Dry Cow Therapy? Tips for a Successful Dry-Off","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","datePublished":"2022-01-27T19:22:31+00:00","dateModified":"2022-01-27T20:13:17+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Benefits of Selective Dry Cow Therapy - key tips from an experienced veterinarian for a successful dry-off, including SDCT program protocols & PCR diagnostics.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","width":1024,"height":683,"caption":"Cows eating, lined up in an open-air stable."},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/tips-for-a-successful-dry-off-using-selective-dry-cow-therapy-sdct\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Tips for a Successful Dry-Off Using Selective Dry Cow Therapy (SDCT)"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":83,"label":"Animal Health and AgriGenomics"},{"value":172,"label":"General"}],"post_tag":[{"value":2232,"label":"bovine mastitis"},{"value":46,"label":"Real Time PCR"},{"value":2241,"label":"SDCT"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg",760,507,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":1,"category_info":[{"term_id":83,"name":"Animal Health and AgriGenomics","slug":"animal-health-and-agrigenomics","term_group":0,"term_taxonomy_id":83,"taxonomy":"category","description":"","parent":0,"count":65,"filter":"raw","meta":[],"cat_ID":83,"category_count":65,"category_description":"","cat_name":"Animal Health and AgriGenomics","category_nicename":"animal-health-and-agrigenomics","category_parent":0},{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":158,"filter":"raw","meta":[],"cat_ID":172,"category_count":158,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":2232,"name":"bovine mastitis","slug":"bovine-mastitis","term_group":0,"term_taxonomy_id":2232,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":46,"name":"Real Time PCR","slug":"real-time-pcr","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":55,"filter":"raw","meta":[]},{"term_id":2241,"name":"SDCT","slug":"sdct","term_group":0,"term_taxonomy_id":2241,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19697,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/allogeneic-cell-therapies-enhancing-patient-access-via-off-the-shelf-options\/","url_meta":{"origin":16081,"position":0},"title":"Allogeneic cell therapies: Enhancing patient access via off-the-shelf options","author":"Behind The Bench Staff","date":"May 16, 2026","format":false,"excerpt":"Chimeric Antigen Receptor (CAR) T cell therapy has transformed treatment paradigms for hematologic malignancies. However, most FDA-approved CAR-T cell therapies today are autologous, meaning they are manufactured individually from each patient\u2019s own T cells. While effective, this approach presents significant manufacturing constraints, including long timelines, dependence on patient health for\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"CTx Feature Image","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19392,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/raw-material-considerations-for-cell-therapy-manufacturing\/","url_meta":{"origin":16081,"position":1},"title":"Raw material considerations for cell therapy manufacturing","author":"Behind The Bench Staff","date":"February 12, 2026","format":false,"excerpt":"In cell therapy manufacturing, the lack of definitive regulatory frameworks often makes the process of selecting and qualifying raw materials complex and unclear. In this blog post, we will explore the key considerations for choosing raw materials in cell therapy manufacturing and the importance of early selection in ensuring production\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19837,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/managing-formulation-fill-finish-in-the-car-t-cell-manufacturing-process\/","url_meta":{"origin":16081,"position":2},"title":"Managing Formulation, Fill &amp; Finish in the CAR T-Cell Manufacturing Process","author":"Behind The Bench Staff","date":"July 28, 2026","format":false,"excerpt":"Chimeric antigen receptor (CAR)-T cell therapies represent a paradigm shift in medicine, offering personalized, potentially curative treatments for cancer and other serious diseases. Unlike traditional biologics, CAR T-cell products are living therapeutics. Highly sensitive cells whose quality, safety, and efficacy depend on careful handling at every step of the manufacturing\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Scientist working in a lab","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":16081,"position":3},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19579,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/liquid-biopsy-cancer-research-ngs-pcr\/","url_meta":{"origin":16081,"position":4},"title":"From Discovery to Monitoring: How Sequencing and PCR Work Together in Oncology Research","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"Scientific, joins the Absolute Gene-ius podcast to discuss how molecular technologies are advancing precision oncology research. With experience spanning clinical laboratory research, digital PCR research applications, and next-generation sequencing (NGS), Dr. Sollweck shares how scientists are addressing critical unmet needs in cancer research. From liquid biopsy research strategies to minimal\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Sollweck-headshot-200x250_Jordan-Ruggieri.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":19435,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/scaling-human-relevant-oncology-testing-oncopro-tumoroids-on-screenin3ds-upscale-platform\/","url_meta":{"origin":16081,"position":5},"title":"Scaling Human-Relevant Oncology Testing: OncoPro Tumoroids on ScreenIn3D\u2019s UpScale Platform","author":"Behind The Bench Staff","date":"February 25, 2026","format":false,"excerpt":"The United States National Institutes of Health has prioritized human cell-based in vitro approaches to \u201cmodel human disease and capture human variability and patient-specific characteristics,\u201d complementing the U.S. Food and Drug Administration\u2019s goals to use advanced in vitro assays as a New Approach Methodology (NAM) that could reduce animal testing.\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/HuCo021320-screen-v2-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/01\/cows-eating-1024x683-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16081","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=16081"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16081\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/16113"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=16081"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=16081"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=16081"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=16081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}