{"id":16898,"date":"2022-08-08T23:45:09","date_gmt":"2022-08-08T23:45:09","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=16898"},"modified":"2022-08-17T16:20:56","modified_gmt":"2022-08-17T16:20:56","slug":"diagnosis-prevention-control-blue-tongue-virus","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/","title":{"rendered":"Diagnosis, Prevention and Control of Blue Tongue Virus"},"content":{"rendered":"<h2>Is BTV Worldwide?<\/h2>\n<h3>New Serotypes Rapidly Evolving and Spreading to New Areas<\/h3>\n<p>Bluetongue virus (BTV) is often thought of as a seasonal challenge; however, livestock producers should consider it a serious concern due to the emergence of<strong> new BTV serotypes and their ability to spread, evolve, and adapt to new geographical areas<\/strong>.<\/p>\n<p>Bluetongue is an infectious but noncontagious arthropod-borne disease that primarily affects domestic and wild ruminants. It is caused by a complex non-enveloped virus that has a capsid and a double-stranded RNA genome. BTV is considered a rapidly evolving pathogen [1]; there are 29 different serotypes, and the virulence and mortality rate of the different strains vary considerably.<\/p>\n<h3>How is BTV Transmitted?<\/h3>\n<p>BTV has been identified around the world and is transmitted by the various <em>Culicoides<\/em> biting midge species that inhabit different regions. <img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-12426 size-medium\" title=\"BTV has been identified around the world and is transmitted by the various Culicoides biting midge\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/05\/colicoides_midge-300x242.jpg\" alt=\"A close-up photo of a Culicoides midge, a small flying insect\" width=\"300\" height=\"242\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/05\/colicoides_midge-300x242.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/05\/colicoides_midge.jpg 457w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>While BTV is transmitted in tropical regions throughout the year, infection is much more likely during periods of warm weather, and most infections occur during the late summer and autumn months. Cattle are the reservoir host for BTV. Midges become infected after feeding on the blood of an infected animal, and then the virus reproduces in the midge until a high titer is reached, enabling transmission to other susceptible animals.<\/p>\n<p>BTV is not transmitted by direct or indirect contact between animals in the absence of the <em>Culicoides<\/em> vector. However, it can be transmitted <em>in utero<\/em> from mother to baby. Bluetongue does not affect humans, nor is there any risk of the disease being contracted or spread through meat or milk.<\/p>\n<p>BTV\u00ad-free countries often prohibit livestock movement from BTV-endemic regions. Because of this, the annual economic damage in lost trade is estimated at $3 billion [2].<\/p>\n<h2>BTV is Expanding Around the World<\/h2>\n<p>Globally, BTV is currently distributed at latitudes between approximately 53\u00b0N and 35\u00b0S, which are broadly the tropical and subtropical regions. However, the virus is known to be expanding into the northern hemisphere. In Europe, bluetongue has been confirmed in the Balearic Islands, Sardinia, Sicily, Corsica, and regions of Italy, Spain, France, and Portugal [3]. In recent years the disease has also been detected in the Netherlands, in an area close to the border with Belgium and Germany.<\/p>\n<h3>BTV Detection in the European Union<\/h3>\n<p>The EU Member States map shows BTV-free countries (as of July 2022) in white (Figure 1). Countries that are not BTV-free are shown in colors that indicate the specific circulating serotypes in that region.<\/p>\n<div id=\"attachment_16899\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-16899\" class=\"wp-image-16899 size-large\" title=\"Bluetongue Virus is Spreading into Northern Areas of the Globe\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-1024x717.jpg\" alt=\"Map of Europe indicating EU members and spread of BTV\" width=\"760\" height=\"532\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-1024x717.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-300x210.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-768x538.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-1536x1076.jpg 1536w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/map-eu-bluetongue-restricted-zones-2502x1753-1-2048x1435.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-16899\" class=\"wp-caption-text\">Figure 1. Distribution of bluetongue virus throughout Europe. \u00a9 European Union, 1995-2022. Retrieved 01 August 2022, from <a title=\"Distribution of bluetongue virus throughout Europe\" href=\"https:\/\/ec.europa.eu\/food\/animals\/animal-diseases\/surveillance-eradication-programmes-and-disease-free-status\/bluetongue_en\" target=\"_blank\" rel=\"noopener\">https:\/\/ec.europa.eu\/food\/animals\/animal-diseases\/surveillance-eradication-programmes-and-disease-free-status\/bluetongue_en<\/a>. Used under the terms of the Creative Commons Attribution 4.0 International license (CC BY 4.0).<\/p><\/div>\n<h3>Further Global Distribution<\/h3>\n<p>It is generally recognized that BTV is endemic throughout most of South Africa; 22 of the 29 known serotypes have been detected in the region. Novel BTV serotypes have been found in historically enzootic (endemic) countries or regions, including the southeastern United States, Israel, Australia, and South America, indicating diverse pathways of transmission.<\/p>\n<h2>How to Identify BTV<\/h2>\n<p>Bluetongue gets its name from the vascular damage caused by the virus that results in severe swelling of the tongue. In ruminants, BTV can cause abortions, malformed fetuses, and even death. Other symptoms include inflammation of the mucous membranes, congestion, swelling, and hemorrhage.<\/p>\n<h3>Visual Identification and Clinical Signs<\/h3>\n<p>Visual identification of BTV infection can be challenging, especially in cattle since the clinical signs are similar to symptoms of other diseases. Often, cattle may become infected and exhibit a high level of viremia that lasts a long time, even while not necessarily showing outward signs of infection. In sheep, more classical clinical signs are identified, including fever, lameness, and edema.<\/p>\n<h3>Bluetongue Virus Serotypes Have Different Properties<\/h3>\n<p>The clinical signs in animals infected by different BTV serotypes can vary because each serotype has different properties. For example, the BTV-8 strain that was circulating from 2006 to 2009 caused quite high morbidity in both cattle and sheep.<\/p>\n<h2>Prevention and Treatment of BTV<\/h2>\n<p>There is no treatment available for BTV infection. However, according to The Pirbright Institute, the central difficulty in fighting BTV is that infection or vaccination of an animal with one serotype does not create immunity to any of the other serotypes. Virus protein 2 (VP2), which is located at the surface of the virus, both determines the serotype and activates the host animal\u2019s immune response. Since vaccines exist for only a few of the serotypes, knowing the serotype of BTV that is causing a given outbreak in a herd or flock is key to finding the correct BTV vaccine that will protect your animals [4].<\/p>\n<h3>Vaccination and Biosecurity to Mitigate Risk<\/h3>\n<p>If a farm is BTV-free, a veterinarian can identify the regional risk and help make an informed decision on whether vaccination makes sense, based on the farm\u2019s business risk and the diagnostic testing results in the region. If BTV has been found in your region or is a seasonal threat, make an appointment with your veterinarian and remain vigilant.<\/p>\n<h2>Diagnosing BTV<\/h2>\n<h3>Real-Time PCR-Based Detection Kit<\/h3>\n<p>Infected cattle without clinical signs may be an invisible source of BTV within a herd or region. Many European countries are establishing surveillance and management programs to help veterinarians and farmers battle BTV when it is detected. Some EU countries are working toward disease-free status using eradication programs.<\/p>\n<p>The Applied Biosystems\u2122 VetMAX\u2122 BTV NS3 All Genotypes Kit is a polymerase chain reaction (PCR)-based detection kit that has been <strong>validated by the Pirbright Institute, an OIE reference lab for BTV<\/strong>. (The kit was formerly called the LSI VetMAX BlueTongue Virus NS3\u2014All Genotypes Kit.) The VetMAX BTV NS3 kit can <strong>quickly and reliably identify if BTV is present and which strain is involved<\/strong>. It serves to specifically detect from <strong>one to 27 genotypes of BTV using real-time reverse transcription PCR<\/strong>.<\/p>\n<h3>Highly Sensitive, Specific Detection of BTV<\/h3>\n<p>Each RNA sample is analyzed in a single well; the same well is used to specifically detect both the viral RNA of BTV and an internal positive control (IPC). A positive IPC signifies both successful extraction and the absence of PCR inhibitors in the sample. The kit can be used on viral RNA extracted from whole blood (in EDTA tubes), spleen, or organs of aborted animals. It does not detect EHDV (epizootic hemorrhagic disease virus), a relative of BTV. This kit enables highly sensitive and specific detection of BTV nucleic acid in animal samples, allowing for reliable and rapid screening and identification of infected animals.<\/p>\n<p>&nbsp;<\/p>\n<h2>Related<\/h2>\n<p><a title=\"Bovine\/Cattle Disease Solutions - BTV\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/animal-health\/bovine-cattle-diagnostic-solutions\/bovine-diseases.html?open=btv#btv\" target=\"_blank\" rel=\"noopener\">\u00bb Bovine\/Cattle Disease Solutions \u2013 BTV \u2013 Epidemiology, Signs, PCR Solutions<\/a><\/p>\n<p><a title=\"Thermo Fisher Scientific Bovine\/Cattle Diagnostic Solutions\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/animal-health\/bovine-cattle-diagnostic-solutions.html\" target=\"_blank\" rel=\"noopener\">\u00bb Bovine\/Cattle Diagnostic Solutions<\/a><\/p>\n<p><a title=\"Animal Health \u2013 Meeting Today's Veterinary Diagnostic Needs\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/animal-health.html\" target=\"_blank\" rel=\"noopener\">\u00bb Animal Health Solutions<\/a><\/p>\n<p>&#8212;<\/p>\n<h2>References<\/h2>\n<ol start=\"1\">\n<li>Alkhamis MA et al. (2020) Global emergence and evolutionary dynamics of bluetongue virus. <em>Scientific Reports<\/em> 10. doi:10.1038\/s41598-020-78673-9.<\/li>\n<li>Rushton J, Lyons N (2016) Economic impact of bluetongue: a review of the effects on production. <em>Veterinaria Italiana<\/em> 51:401\u2013406. doi: 10.12834\/VetIt.646.3183.1.<\/li>\n<li>Eurpoean Commission (2006) Q&amp;A bluetongue. <em>Press corner<\/em>. https:\/\/ec.europa.eu\/commission\/presscorner\/detail\/en\/MEMO_06_309.<\/li>\n<li>The Pirbright Institute (2015) Bluetongue virus. <a href=\"https:\/\/www.pirbright.ac.uk\/bluetongue\">https:\/\/www.pirbright.ac.uk\/bluetongue<\/a>.<\/li>\n<\/ol>\n<p>&#8212;<br \/>\nFor Veterinary Use Only. For <em>In<\/em> <em>Vitro<\/em> Use Only. Regulatory requirements vary by country; products may not be available in your geographic area. EXT3292 0722<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Is BTV Worldwide? New Serotypes Rapidly Evolving and Spreading to New Areas Bluetongue virus (BTV) is often thought of as a seasonal challenge; however, livestock producers should consider it a serious concern due to the emergence of new BTV serotypes and their ability to spread, evolve, and adapt to new geographical areas. Bluetongue is an<\/p>\n","protected":false},"author":120,"featured_media":16920,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[83,172],"tags":[2233,2262,2263,2295,2296],"division":[],"class_list":["post-16898","post","type-post","status-publish","format-standard","has-post-thumbnail","category-animal-health-and-agrigenomics","category-general","tag-animal-health","tag-bovine-diseases","tag-cattle","tag-ovine-diseases","tag-sheep","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Bluetongue Global Spread - Diagnosis, Prevention and Control<\/title>\n<meta name=\"description\" content=\"Get information on bluetongue virus (BTV) - where it&#039;s found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Diagnosis, Prevention and Control of Blue Tongue Virus\" \/>\n<meta property=\"og:description\" content=\"Get information on bluetongue virus (BTV) - where it&#039;s found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-08T23:45:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-17T16:20:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"headline\":\"Diagnosis, Prevention and Control of Blue Tongue Virus\",\"datePublished\":\"2022-08-08T23:45:09+00:00\",\"dateModified\":\"2022-08-17T16:20:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/\"},\"wordCount\":1189,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/08\\\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg\",\"keywords\":[\"animal health\",\"bovine diseases\",\"cattle\",\"ovine diseases\",\"sheep\"],\"articleSection\":[\"Animal Health and AgriGenomics\",\"General\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/\",\"name\":\"Bluetongue Global Spread - Diagnosis, Prevention and Control\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/08\\\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg\",\"datePublished\":\"2022-08-08T23:45:09+00:00\",\"dateModified\":\"2022-08-17T16:20:56+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"description\":\"Get information on bluetongue virus (BTV) - where it's found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/08\\\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/08\\\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg\",\"width\":1200,\"height\":350,\"caption\":\"concept art of sheep\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/diagnosis-prevention-control-blue-tongue-virus\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Diagnosis, Prevention and Control of Blue Tongue Virus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Bluetongue Global Spread - Diagnosis, Prevention and Control","description":"Get information on bluetongue virus (BTV) - where it's found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/","og_locale":"en_US","og_type":"article","og_title":"Diagnosis, Prevention and Control of Blue Tongue Virus","og_description":"Get information on bluetongue virus (BTV) - where it's found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-08-08T23:45:09+00:00","article_modified_time":"2022-08-17T16:20:56+00:00","og_image":[{"width":1200,"height":350,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"headline":"Diagnosis, Prevention and Control of Blue Tongue Virus","datePublished":"2022-08-08T23:45:09+00:00","dateModified":"2022-08-17T16:20:56+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/"},"wordCount":1189,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","keywords":["animal health","bovine diseases","cattle","ovine diseases","sheep"],"articleSection":["Animal Health and AgriGenomics","General"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/","name":"Bluetongue Global Spread - Diagnosis, Prevention and Control","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","datePublished":"2022-08-08T23:45:09+00:00","dateModified":"2022-08-17T16:20:56+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"description":"Get information on bluetongue virus (BTV) - where it's found, how it spreads, identification and clinical signs, diagnosis via real-time PCR, prevention, control.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","width":1200,"height":350,"caption":"concept art of sheep"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/diagnosis-prevention-control-blue-tongue-virus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Diagnosis, Prevention and Control of Blue Tongue Virus"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":83,"label":"Animal Health and AgriGenomics"},{"value":172,"label":"General"}],"post_tag":[{"value":2233,"label":"animal health"},{"value":2262,"label":"bovine diseases"},{"value":2263,"label":"cattle"},{"value":2295,"label":"ovine diseases"},{"value":2296,"label":"sheep"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1-1024x299.jpg",760,222,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":83,"name":"Animal Health and AgriGenomics","slug":"animal-health-and-agrigenomics","term_group":0,"term_taxonomy_id":83,"taxonomy":"category","description":"","parent":0,"count":65,"filter":"raw","meta":[],"cat_ID":83,"category_count":65,"category_description":"","cat_name":"Animal Health and AgriGenomics","category_nicename":"animal-health-and-agrigenomics","category_parent":0},{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":2233,"name":"animal health","slug":"animal-health","term_group":0,"term_taxonomy_id":2233,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]},{"term_id":2262,"name":"bovine diseases","slug":"bovine-diseases","term_group":0,"term_taxonomy_id":2262,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":2263,"name":"cattle","slug":"cattle","term_group":0,"term_taxonomy_id":2263,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":2295,"name":"ovine diseases","slug":"ovine-diseases","term_group":0,"term_taxonomy_id":2295,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":2296,"name":"sheep","slug":"sheep","term_group":0,"term_taxonomy_id":2296,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19888,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/streptococcus-pneumoniae-serotype-identification-qpcr-nested-pcr\/","url_meta":{"origin":16898,"position":0},"title":"qPCR, Nested PCR, and the Search for Bacterial Serotypes","author":"Ashleigh Barlow","date":"August 5, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Donna Paznar, former Head of Molecular Infection Diagnostics at the Medical University of Vienna, discusses her research on Streptococcus pneumoniae and its impact across the Austrian population. She explains why children can act as asymptomatic reservoirs, why tracking bacterial serotypes matters, and\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Donna Paznar discussing molecular methods for identifying Streptococcus pneumoniae serotypes.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19645,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/aav-viral-vector-analytics-cdmo\/","url_meta":{"origin":16898,"position":1},"title":"Almost a Virus: How CDMOs Enable Scalable Cell and Gene Therapy","author":"Behind The Bench Staff","date":"April 6, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, Dr. Dan Mitchell, Senior Director of Analytical Development and Quality Control at Matica Biotechnology, explains how contract development and manufacturing organizations (CDMOs) support the advancement of cell and gene therapies. The discussion focuses on viral vector development, analytical strategies, and the technologies used to\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Headshot of a man with dark hair and a beard wearing a suit and tie against a neutral background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19748,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/andes-virus-rt-qpcr-detection-workflow\/","url_meta":{"origin":16898,"position":2},"title":"Responding to Hantavirus: Advancing Rapid Molecular Detection","author":"Behind The Bench Staff","date":"May 14, 2026","format":false,"excerpt":"Article Summary Laboratories responding to the emerging 2026 Andes hantavirus incident need rapid, scalable molecular workflows that can integrate into existing RT-qPCR infrastructure. This workflow is best suited for public health laboratories, surveillance programs, academic research labs, and high-throughput testing facilities seeking rapid research-use-only (RUO) molecular detection capabilities. By combining\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Illustration of hantavirus transmission showing rodent-derived viral particles entering the human respiratory system.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19676,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/avian-influenza-qpcr-assay-failure\/","url_meta":{"origin":16898,"position":3},"title":"Avian Influenza qPCR Testing: How Viral Evolution Contributes to Assay Failure\u2014and How Labs Can Stay Ahead","author":"Behind The Bench Staff","date":"May 1, 2026","format":false,"excerpt":"Molecular veterinary diagnostic laboratories rely on reverse transcriptase real-time PCR (RT qPCR) assays to detect avian influenza virus (AIV) quickly and accurately. These assays are central to surveillance programs, outbreak response, and disease control\u2014particularly for highly pathogenic avian influenza (HPAI) strains such as H5Nx. As Influenza A viruses continue to\u2026","rel":"","context":"In &quot;Animal Health and AgriGenomics&quot;","block_context":{"text":"Animal Health and AgriGenomics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/animal-health-and-agrigenomics\/"},"img":{"alt_text":"Chickens in a flock on a farm representing poultry populations monitored for avian influenza surveillance.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19828,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cyclospora-molecular-testing-gi-pathogens\/","url_meta":{"origin":16898,"position":4},"title":"Cyclospora Outbreak in the United States: Why Rapid Molecular Testing Matters for Gastrointestinal Pathogens","author":"Ashleigh Barlow","date":"July 17, 2026","format":false,"excerpt":"Fresh produce is one of the most common sources of Cyclospora outbreaks. Molecular testing helps laboratories rapidly identify Cyclospora cayetanensis alongside other gastrointestinal pathogens from a single specimen. Article Summary The United States is currently investigating a multistate outbreak of Cyclospora cayetanensis, a foodborne parasite that causes prolonged diarrheal illness.\u2026","rel":"","context":"In &quot;Food Safety&quot;","block_context":{"text":"Food Safety","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/food-safety\/"},"img":{"alt_text":"Magnified view of parasite contamination on fresh leafy greens, illustrating foodborne pathogen detection.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Cyclospora-Image-6000x4480_Geoffrey-Cassell-scaled.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":16898,"position":5},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/08\/blog-banner-BTV-bluetongue-virus-PG2598-PJT8164-COL021370-1200x350-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=16898"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/16898\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/16920"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=16898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=16898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=16898"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=16898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}