{"id":17235,"date":"2022-10-17T18:38:09","date_gmt":"2022-10-17T18:38:09","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=17235"},"modified":"2022-10-27T17:33:36","modified_gmt":"2022-10-27T17:33:36","slug":"understanding-ct-values","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/","title":{"rendered":"Understanding Ct Values in Real-Time PCR"},"content":{"rendered":"<p>By John Pfeifer<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right\" title=\"A sample amplification plot\" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg\" alt=\"A sample amplification plot \" width=\"440\" height=\"332\" \/><\/p>\n<p>Real-time PCR (polymerase chain reaction) is a technology that detects amplification of a specific genetic sequence after each PCR cycle. This technology can detect or quantify gene sequences for a wide variety of applications.<\/p>\n<p>A real-time PCR assay includes a combination of oligonucleotides designed to amplify and detect a specific gene target. Real-time PCR assays often consist of two PCR primers and a fluorescently labeled probe, called the TaqMan probe.<\/p>\n<p>Real-time PCR tests or experiments are usually programmed to run 40 cycles, but high-value data span only a few cycles and those cycles can differ sample to sample. How can high-value data points be selected from real-time PCR data?<\/p>\n<h2>Amplification Plot<\/h2>\n<p>Real-time PCR data are often represented in a graph called an amplification plot (Figure 1). The vertical axis is in fluorescent units, and the measurement is often called \u0394Rn, which is a baseline subtracted normalized reporter. The horizontal axis is in PCR cycle numbers.<\/p>\n<p>Baseline is defined as data from the early PCR cycles before amplification signal becomes detectable. In an amplification plot with a linear vertical axis scale, the baseline should appear as a flat line. During the baseline cycles, target gene amplification may have been happening, but growing reporter signal (e.g., from TaqMan probes) has not accumulated sufficiently to be visible. If target is present in the reaction, eventually amplification signal will emerge from the baseline.<\/p>\n<p><strong>Figure 1<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" title=\"Amplification plot\" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/figure201-8.jpg\" alt=\"A sample amplification plot\" width=\"451\" height=\"215\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<h2>Gene Quantification<\/h2>\n<p>Real-time PCR is the gold standard for gene quantification. The reason is the remarkable consistency of exponential-phase amplification. Exponential (a.k.a., geometric, logarithmic) is the first phase of PCR, in which all the reactants\u2014such as primers, DNA polymerase, dNTPs, etc.\u2014are in excess, fueling consistent efficiency. This consistency means the initial target gene quantity in the PCR reaction will determine when amplification signal emerges from the baseline, as illustrated in Figure 2. The greater the starting target quantity, the earlier the amplification signal will emerge.<\/p>\n<p><strong>Figure 2<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" title=\"Amplification plot showing how target quantity affects signal emergence from baseline\" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/figure202-8.jpg\" alt=\"Amplification plot showing how target quantity affects signal emergence from baseline\" width=\"374\" height=\"175\" \/><\/strong><\/p>\n<p>One high-value data point is needed from each amplification plot to calculate initial target quantity values. Baseline data points have no quantitative value. Exponential-phase data points have the greatest value. When one of the reactants is no longer adequate to fuel consistent efficiency, exponential phase ends and subsequent data points diminish in value. A method is needed to select exponential-phase data points at a consistent point, so they are comparable within an assay.<\/p>\n<h2>Ct Values<\/h2>\n<p>Single data points derived from real-time PCR amplification plots are called threshold cycles or \u201cCt\u201d (a.k.a., Cq) values. The first and still most popular method of producing Ct values is called baseline-threshold.<\/p>\n<p>In all real-time PCR chemistries, some baseline fluorescence is always present, which can vary somewhat from well to well. This variation is greatly reduced by the baseline subtraction algorithm in real-time PCR software, which sets all baselines to approximately zero. By setting all baselines to zero, thresholds will be set from a consistent starting point.<\/p>\n<p>Threshold is a fluorescent value (\u0394Rn) selected for an assay, from which Ct values will be calculated.\u00a0 Thresholds are usually set within the exponential phase of PCR. Exponential phases are best identified on a log scale y-axis of an amplification plot, where they appear as parallel lines with a positive slope (Figure 3). In the amplification plot, the threshold is seen as a horizontal line.<\/p>\n<p><strong>Figure 3<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" title=\"Amplification plot showing exponential phases\" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/figure203-8.jpg\" alt=\"Amplification plot showing exponential phases\" width=\"391\" height=\"207\" \/><\/strong><\/p>\n<p>The intersection of the threshold and amplification plot produces a Ct value. Ct values are typically not whole numbers.<\/p>\n<h2>Qualitative Results<\/h2>\n<p>Ct values can be used for qualitative assays, such as determining the presence or absence of a pathogen.\u00a0 The absence of a Ct value means the target was not present in that reaction and the presence of a Ct value means the target was present.<\/p>\n<p>Qualitative assays often include a control gene for purposes of quality control. If the control assay Ct value is too high, the validity of a target negative sample result is called into question. For example, there might have been a problem with sample collection, extraction, an inhibitor, etc., that could reduce the sensitivity of the assay below an acceptable level.<\/p>\n<p>For qualitative assays, thresholds are usually fixed to maintain consistency in Ct value calculations each time the assay is run.<\/p>\n<h2>Quantitative Results<\/h2>\n<p>Quantitative results come in multiple types: relative vs. absolute, and amount vs. concentration. In real-time PCR software, the term \u201cquantity\u201d is used generically to encompass all these result types.<\/p>\n<p>Absolute quantification with real-time PCR is determining the molecular amount or concentration of the target. Relative quantification is determining quantities with nonmolecular or arbitrary units.<\/p>\n<p>Reporting Ct values as final quantitative values is not recommended, because Ct values are abstract, incomplete and mathematically complex. A Ct value alone is incomplete quantitatively because the quantitative interpretation of a Ct value depends on the exponential-phase efficiency. As an example of Ct complexity, standard deviation Ct does not behave like a standard deviation.<\/p>\n<p>Quantitative results should be reported as quantities, which are complete, mathematically simpler data points. Quantities can be calculated from Ct values and exponential-phase efficiency:<\/p>\n<h3>Equation 1<\/h3>\n<p style=\"text-align: center\">Quantity ~ e<sup>-Ct<\/sup><\/p>\n<p>Where:<\/p>\n<p style=\"padding-left: 30px\">Quantity = initial target gene quantity<\/p>\n<p style=\"padding-left: 30px\">e = exponential-phase efficiency, ideally 2 (target doubles each cycle)<\/p>\n<p style=\"padding-left: 30px\">Ct = threshold cycle<\/p>\n<p>Real-time PCR quantification involving biological samples often includes a normalizer gene. Such a gene is used to measure sample mass and normalize target amount by sample mass to produce target concentration, which is biologically relevant.<\/p>\n<p>Calibration is defining the unit of a data set. A common practice in real-time PCR is to use a sample or average of a group of samples as a \u201ccalibrator\u201d (a.k.a., reference sample or group). The calibrator sample or group will have a relative quantity (RQ) of 1 and all other sample RQ values will be relative to that. Calibrators may either be relative or absolute.<\/p>\n<p>In a 1997 document titled \u201cUser Bulletin #2,\u201d Equation 1 was modified for sample mass normalization and calibration, and the exponential efficiencies were set to 100%. The resulting equation was called the comparative Ct or \u0394\u0394Ct method:<\/p>\n<h3>Equation 2<\/h3>\n<p style=\"text-align: center\">Relative Quantity = 2<sup>-\u0394\u0394<\/sup><sup>Ct<\/sup><\/p>\n<p>Where:<\/p>\n<p style=\"padding-left: 30px\">\u0394\u0394Ct is the Ct value normalized by sample mass and calibrated.<\/p>\n<p style=\"padding-left: 30px\">Note, normalization of Ct values is performed through subtraction, rather than division, and the symbol \u0394\u00a0indicates subtraction.<\/p>\n<p>For quantitative assays, thresholds may be set within a range of \u0394Rn values in the exponential phase (Figure 4). In a log y-axis amplification plot, exponential phases end where the plots begin to curve to the right. Thresholds should not be set in this curved region due to worsening precision. In addition, thresholds should not be set too low where the data appear more variable. This variability is caused by poor signal-to-noise ratio.<\/p>\n<p>Adjusting the threshold changes the Ct values of that assay, but if the threshold is set within a recommended range, Ct value changes are consistent. When using the \u0394\u0394Ct method, consistent Ct value changes do not significantly alter the resulting quantities.<\/p>\n<p>Thresholds are not required to be the same for different assays, but they may be set to the same value for convenience if that threshold is acceptable for each assay.<\/p>\n<p>Visual assessment of thresholds in the amplification plot is recommended to ensure they are in an acceptable range, even if using an automatic threshold algorithm.<\/p>\n<p><strong>Figure 4<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" title=\"Amplification plot showing thresholds\" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/figure204-8.jpg\" alt=\"Amplification plot showing thresholds\" width=\"369\" height=\"194\" \/><\/strong><\/p>\n<h2>Relative Threshold Method<\/h2>\n<p>Some real-time PCR software programs offer an alternative method to calculate Ct values called the relative threshold method. This method is automated, so there are no baseline or threshold settings to assess or modify. The algorithm identifies likely amplification signals and calculates Ct values at a consistent point based on the shape of each amplification plot. When using the relative threshold method, Ct values will be displayed as \u201cCrt\u201d values in the software, which identifies the method used to obtain them.<\/p>\n<p>Real-time PCR software calculates quality control values, which may include Cq confidence, amp score and amp status. Assessing these quality control values is recommended to ensure C<sub>t<\/sub> values were obtained from true amplifications.<\/p>\n<h2>Equivalent Ct Values<\/h2>\n<p>In addition to Ct values, some real-time PCR software programs display \u201cequivalent\u201d Ct values, which are what the Ct values would have been if the assay had 100% exponential-phase efficiency. If the assay efficiency remains at the default 100% in the software, Ct values and equivalent Ct values will be the same.<\/p>\n<p>Changing the efficiency of an assay from the default 100% should only be done with great caution. A common method to calculate exponential-phase efficiency is based on the slope of a standard curve, but standard curve slopes fluctuate randomly. Using only assays with 100% exponential-phase efficiency for real-time PCR is recommended, because assays with low efficiencies create unwanted complexities. For example, if an assay has low efficiency, measuring the efficiency accurately will be difficult. In addition, the 40 cycles routinely used in real-time PCR will need to be increased to maintain sensitivity.<\/p>\n<p>This article only scratches the surface of real-time PCR (qPCR). To learn more, visit these helpful resources:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/content\/dam\/LifeTech\/Documents\/PDFs\/PG1503-PJ9169-CO019879-Re-brand-Real-Time-PCR-Understanding-Ct-Value-Americas-FHR.pdf\" target=\"_blank\" rel=\"noopener\">Understanding C<sub>t<\/sub> Application Note<\/a><\/li>\n<li>Taq Talk video, Episode 3: <a href=\"http:\/\/players.brightcove.net\/3663210762001\/XCI1AMd08_default\/index.html?videoId=6277032743001\" target=\"_blank\" rel=\"noopener\">Understanding C<sub>t<\/sub> values in real-time PCR<\/a><\/li>\n<li><a href=\"http:\/\/players.brightcove.net\/3663210762001\/XCI1AMd08_default\/index.html?videoId=6291526717001\" target=\"_blank\" rel=\"noopener\">Taq Talk video, Episode 12: Baselines in real-time PCR<\/a><\/li>\n<li>Taq Talk video, Episode 13: <a href=\"http:\/\/players.brightcove.net\/3663210762001\/XCI1AMd08_default\/index.html?videoId=6292686179001\" target=\"_blank\" rel=\"noopener\">Real-time PCR thresholds and where to place them<\/a><\/li>\n<li>Taq Talk video, Episode 14: <a href=\"http:\/\/players.brightcove.net\/3663210762001\/XCI1AMd08_default\/index.html?videoId=6293923322001\" target=\"_blank\" rel=\"noopener\">How to tell if C<sub>t<\/sub> values are real signal or background noise<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/life-science\/digital-experience.html\" target=\"_blank\" rel=\"noopener\">qPCR Handbook 2.0, digital experience<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>By John Pfeifer Real-time PCR (polymerase chain reaction) is a technology that detects amplification of a specific genetic sequence after each PCR cycle. This technology can detect or quantify gene sequences for a wide variety of applications. A real-time PCR assay includes a combination of oligonucleotides designed to amplify and detect a specific gene target.<\/p>\n","protected":false},"author":120,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172,108],"tags":[2317,20,46],"division":[],"class_list":["post-17235","post","type-post","status-publish","format-standard","category-general","category-lab-tips-and-tricks","tag-gene-quantification","tag-qpcr","tag-real-time-pcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Understanding Ct Values in Real-Time PCR<\/title>\n<meta name=\"description\" content=\"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding Ct Values in Real-Time PCR\" \/>\n<meta property=\"og:description\" content=\"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-10-17T18:38:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-10-27T17:33:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"headline\":\"Understanding Ct Values in Real-Time PCR\",\"datePublished\":\"2022-10-17T18:38:09+00:00\",\"dateModified\":\"2022-10-27T17:33:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/\"},\"wordCount\":1526,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/10\\\/amplification20plot_svt05_p1s1_ldfa-3.jpg\",\"keywords\":[\"gene quantification\",\"qPCR\",\"Real Time PCR\"],\"articleSection\":[\"General\",\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/\",\"name\":\"Understanding Ct Values in Real-Time PCR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/10\\\/amplification20plot_svt05_p1s1_ldfa-3.jpg\",\"datePublished\":\"2022-10-17T18:38:09+00:00\",\"dateModified\":\"2022-10-27T17:33:36+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"description\":\"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/10\\\/amplification20plot_svt05_p1s1_ldfa-3.jpg\",\"contentUrl\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/10\\\/amplification20plot_svt05_p1s1_ldfa-3.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/understanding-ct-values\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding Ct Values in Real-Time PCR\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Understanding Ct Values in Real-Time PCR","description":"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/","og_locale":"en_US","og_type":"article","og_title":"Understanding Ct Values in Real-Time PCR","og_description":"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-10-17T18:38:09+00:00","article_modified_time":"2022-10-27T17:33:36+00:00","og_image":[{"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg","type":"","width":"","height":""}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"headline":"Understanding Ct Values in Real-Time PCR","datePublished":"2022-10-17T18:38:09+00:00","dateModified":"2022-10-27T17:33:36+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/"},"wordCount":1526,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg","keywords":["gene quantification","qPCR","Real Time PCR"],"articleSection":["General","Lab Tips and Tricks"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/","name":"Understanding Ct Values in Real-Time PCR","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg","datePublished":"2022-10-17T18:38:09+00:00","dateModified":"2022-10-27T17:33:36+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"description":"Single data points derived from real-time PCR amplification plots are called threshold cycles or Ct values. Ct values are produced via the baseline-threshold method.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#primaryimage","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg","contentUrl":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/10\/amplification20plot_svt05_p1s1_ldfa-3.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-ct-values\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Understanding Ct Values in Real-Time PCR"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"},{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":2317,"label":"gene quantification"},{"value":20,"label":"qPCR"},{"value":46,"label":"Real Time PCR"}]},"featured_image_src_large":false,"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":102,"filter":"raw","meta":[],"cat_ID":108,"category_count":102,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":2317,"name":"gene quantification","slug":"gene-quantification","term_group":0,"term_taxonomy_id":2317,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":20,"name":"qPCR","slug":"qpcr","term_group":0,"term_taxonomy_id":20,"taxonomy":"post_tag","description":"","parent":0,"count":37,"filter":"raw","meta":[]},{"term_id":46,"name":"Real Time PCR","slug":"real-time-pcr","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":55,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19271,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","url_meta":{"origin":17235,"position":0},"title":"Multiplex vs. Singleplex qPCR: What do I need to know?","author":"Ashleigh Barlow","date":"December 3, 2025","format":false,"excerpt":"Real-time PCR (qPCR) has transformed how scientists detect and quantify nucleic acid targets, offering analytical sensitivity, speed, and scalability. Many real-time PCR reactions measure a single target per well \u2014 a setup called singleplex qPCR. However, the effectiveness of real-time PCR can be increased by an approach called multiplex qPCR.\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19566,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/pcr-inhibitors-digital-pcr\/","url_meta":{"origin":17235,"position":1},"title":"When PCR Gets Dirty &#8211; Tackling PCR Inhibitors","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"In this first Absolute Gene-ius: Science Snapshot episode, hosts Jordan Ruggieri and Lisa Crawford revisit expert insights on one persistent molecular biology challenge: PCR inhibitors. Across wastewater surveillance, environmental microbiology, and gene therapy manufacturing, inhibitors can distort PCR data and complicate quantification. Featuring perspectives from Ray Ketchum, PhD; Sarah Philo,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19650,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/history-of-qpcr-30-years\/","url_meta":{"origin":17235,"position":2},"title":"qPCR at 30: Advancing Science Together, from Insight to Impact","author":"Behind The Bench Staff","date":"April 7, 2026","format":false,"excerpt":"Celebrating 30 years of qPCR innovation and the scientific partnerships that continue to drive discovery forward. Thirty years ago, a simple but groundbreaking question changed molecular biology: What if DNA amplification could be measured in real time? The answer became quantitative PCR (qPCR), a technology that allows scientists to monitor\u2026","rel":"","context":"In &quot;Perspectives&quot;","block_context":{"text":"Perspectives","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/perspectives\/"},"img":{"alt_text":"Mosaic image of a scientist composed of smaller images representing qPCR technology, instruments, and scientific research advancements.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19922,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/qpcr-master-mix-comparison\/","url_meta":{"origin":17235,"position":3},"title":"Think your supermix is good enough? Prove it.","author":"Ashleigh Barlow","date":"August 21, 2026","format":false,"excerpt":"The chemistry of your qPCR supermix can influence analytical sensitivity, specificity, precision, and overall assay performance. Even when you keep the same instrument, assays, and samples, different master mixes can perform differently. That's why we challenge you to put your supermix to the test. Compare it side by side with\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Applied Biosystems probe-based and SYBR Green qPCR master mixes for real-time PCR workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":17235,"position":4},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19776,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/epigenetic-methylation-analysis-qpcr-dpcr\/","url_meta":{"origin":17235,"position":5},"title":"Epigenetics unlocked: How behavior shapes biology","author":"Ashleigh Barlow","date":"May 28, 2026","format":false,"excerpt":"Article Summary Epigenetics is helping researchers understand how environment, behavior, and molecular regulation intersect. Rather than changing the underlying DNA sequence, epigenetic changes influence how genes are expressed, including when they are turned on, turned off, or regulated in response to biological and environmental signals. In this episode of Absolute\u2026","rel":"","context":"In &quot;Epigenetics&quot;","block_context":{"text":"Epigenetics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/epigenetics\/"},"img":{"alt_text":"Portrait of Dr. Robert Philibert discussing epigenetics, DNA methylation, and behavioral biomarkers.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17235","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=17235"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17235\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=17235"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=17235"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=17235"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=17235"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}