{"id":17430,"date":"2022-11-29T08:00:40","date_gmt":"2022-11-29T08:00:40","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=17430"},"modified":"2022-12-13T14:47:29","modified_gmt":"2022-12-13T14:47:29","slug":"in-line-process-analysis-during-drug-manufacturing","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/","title":{"rendered":"In-line Process Analysis During Drug Manufacturing"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-17432\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg\" alt=\"Drug manufacturing\" width=\"450\" height=\"253\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg 788w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745-768x432.jpg 768w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/>Process monitoring tools are implemented at every stage of the drug manufacturing pipeline. Drug discovery research requires advanced instrumentation to accelerate target discovery and validation through to preclinical development. At the preclinical stage, analyzers enable absorption, distribution, excretion, metabolite monitoring, and more \u2013 each a critical metric in demonstrating the efficacy of candidate molecules. The complexity of drug development is such that robust process analysis must be hard-baked into every phase, which poses logistical and financial challenges.<\/p>\n<p>Process analytical technology (PAT) sampling techniques can largely be categorized into one of four distinct classes: at-line, off-line, in-line, or on-line. Each of these approaches has its merits and disadvantages, but the ideal method for many pharmaceutical companies would be either on- or in-line monitoring.<\/p>\n<p>The main issue with at-line and off-line approaches is that analysis is conducted separately from the process. Samples must be extracted from a bioreactor, for example, before analysis is carried out at the facility (at-line) or in a more remote setting (off-line). Both are akin to quality assurance methods that cannot provide accurate, real-time insights into true product quality. There is an ongoing drive within the pharmaceutical industry to implement PAT systems that offer continuous product analysis in situ. On-line and in-line process analyzers meet these needs.<\/p>\n<h2>What is On-line Process Analysis?<\/h2>\n<p>On-line analysis eliminates the need to transport samples from a process to a separate location, usually by implementing a sampling loop into the system. An integrated device measures a diverted sample directly on the processing line, saving significant amounts of time. The loop may even re-introduce samples to the processing stream to avoid product wastage. Yet there is a simpler, and often more even effective, method when it comes to time-sensitivity and minimization of sample tampering: in-line process analysis.<\/p>\n<h2>In-line Process Analyzers<\/h2>\n<p>In-line and on-line measurements are similar but with one crucial difference. An <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/pharma-biopharma\/manufacturing-control-pharma-biopharma\/process-analytical-technology\/ramina-process-analyzer.html?icid=CAD_blog_LSM_2022Nov\">in-line analyzer<\/a> uses a probe or a sampling interface to monitor the product flow directly \u2013 without needing an integrated sample loop. Solid-state Raman spectroscopy is the go-to solution for continuous process monitoring in pharma development given its flexibility in terms of adapting to different processes and applications with various <a href=\"http:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Catalogs\/ramina-probe-options.pdf?icid=CAD_blog_LSM_2022Nov\">application-specific interfaces<\/a>. In-line Raman analyzers can subsequently be used to monitor a product\u2019s critical quality attributes at myriad points in the development chain.<\/p>\n<p>The core benefit of in-line process analysis, like on-line measurements, is the ability to conduct continuous, real-time quality assurance and control (QA\/QC). This allows manufacturers to continually adjust key process parameters to precisely maintain product quality. Not only are there benefits from a cycle time reduction perspective, but from an efficiency point of view too. Optimizing process parameters on-the-line increases throughput and yield while maximizing equipment utilization\u2013all without ever tampering with the process.<\/p>\n<p>Manufacturers may implement multiple in-line process analyzers at different points in the processing stream. Continuously sampling the product flow at multiple locations in parallel is an excellent way of mitigating product variability in real time. There are numerous benefits to this approach. It significantly reduces the risk of off-specification products being released to markets, which satisfies critical regulatory responsibilities and mitigates the subsequent risk of costly product recalls and irreversible damage to brand reputation.<\/p>\n<p>Other benefits vary depending on the type of in-line process analyzer used and the probe type used. Raman spectroscopy just so happens to be one of the most convenient solutions for in-line process analysis in the pharmaceutical industry.<\/p>\n<p><em>Author: Dean Stuart<\/em><\/p>\n<p><em>Resources: <\/em><\/p>\n<ul>\n<li><em><a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/pharma-biopharma\/manufacturing-control-pharma-biopharma\/process-analytical-technology\/ramina-process-analyzer.html?icid=CAD_blog_LSM_2022Nov\">Raman in-line process analyzers<\/a>\u00a0<\/em><\/li>\n<li><em><a href=\"http:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/ramina-process-analyzer-article.pdf?icid=CAD_blog_LSM_2022Nov\">Raman Spectroscopy Application Note<\/a><\/em><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Process monitoring tools are implemented at every stage of the drug manufacturing pipeline. Drug discovery research requires advanced instrumentation to accelerate target discovery and validation through to preclinical development. At the preclinical stage, analyzers enable absorption, distribution, excretion, metabolite monitoring, and more \u2013 each a critical metric in demonstrating the efficacy of candidate molecules. The<\/p>\n","protected":false},"author":120,"featured_media":17432,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1087],"tags":[2325,2324],"division":[],"class_list":{"0":"post-17430","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-pharmamfg","8":"tag-drugmanufacturing","9":"tag-processanalyzer-processmonitoring-ramananalyzers-quality-assurance-qualitycontrol-raman-spectroscopy-raman-spectroscopy-pharmamanufacturing-pharma","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>In-line Process Analysis During Drug Manufacturing - Behind the Bench<\/title>\n<meta name=\"description\" content=\"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"In-line Process Analysis During Drug Manufacturing\" \/>\n<meta property=\"og:description\" content=\"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-11-29T08:00:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-13T14:47:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"788\" \/>\n\t<meta property=\"og:image:height\" content=\"443\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"In-line Process Analysis During Drug Manufacturing\",\"datePublished\":\"2022-11-29T08:00:40+00:00\",\"dateModified\":\"2022-12-13T14:47:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/\"},\"wordCount\":589,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/11\\\/iStock-1212392745.jpg\",\"keywords\":[\"#drugmanufacturing\",\"#processanalyzer #processmonitoring #ramananalyzers #quality assurance #qualitycontrol #raman spectroscopy #raman #spectroscopy #pharmamanufacturing #pharma\"],\"articleSection\":[\"Pharma &amp; Biotech Manufacturing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/\",\"name\":\"In-line Process Analysis During Drug Manufacturing - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/11\\\/iStock-1212392745.jpg\",\"datePublished\":\"2022-11-29T08:00:40+00:00\",\"dateModified\":\"2022-12-13T14:47:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/11\\\/iStock-1212392745.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/11\\\/iStock-1212392745.jpg\",\"width\":788,\"height\":443,\"caption\":\"Drug manufacturing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/in-line-process-analysis-during-drug-manufacturing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"In-line Process Analysis During Drug Manufacturing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"In-line Process Analysis During Drug Manufacturing - Behind the Bench","description":"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/","og_locale":"en_US","og_type":"article","og_title":"In-line Process Analysis During Drug Manufacturing","og_description":"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-11-29T08:00:40+00:00","article_modified_time":"2022-12-13T14:47:29+00:00","og_image":[{"width":788,"height":443,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"In-line Process Analysis During Drug Manufacturing","datePublished":"2022-11-29T08:00:40+00:00","dateModified":"2022-12-13T14:47:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/"},"wordCount":589,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","keywords":["#drugmanufacturing","#processanalyzer #processmonitoring #ramananalyzers #quality assurance #qualitycontrol #raman spectroscopy #raman #spectroscopy #pharmamanufacturing #pharma"],"articleSection":["Pharma &amp; Biotech Manufacturing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/","name":"In-line Process Analysis During Drug Manufacturing - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","datePublished":"2022-11-29T08:00:40+00:00","dateModified":"2022-12-13T14:47:29+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"How Raman in-line process analyzers in drug manufacturing can help significantly reduce the risk of off-specification products being released to markets.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","width":788,"height":443,"caption":"Drug manufacturing"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/in-line-process-analysis-during-drug-manufacturing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"In-line Process Analysis During Drug Manufacturing"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":1087,"label":"Pharma &amp; Biotech Manufacturing"}],"post_tag":[{"value":2325,"label":"#drugmanufacturing"},{"value":2324,"label":"#processanalyzer #processmonitoring #ramananalyzers #quality assurance #qualitycontrol #raman spectroscopy #raman #spectroscopy #pharmamanufacturing #pharma"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg",760,427,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":1087,"name":"Pharma &amp; Biotech Manufacturing","slug":"pharmamfg","term_group":0,"term_taxonomy_id":1087,"taxonomy":"category","description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","parent":0,"count":60,"filter":"raw","meta":[],"cat_ID":1087,"category_count":60,"category_description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","cat_name":"Pharma &amp; Biotech Manufacturing","category_nicename":"pharmamfg","category_parent":0}],"tag_info":[{"term_id":2325,"name":"#drugmanufacturing","slug":"drugmanufacturing","term_group":0,"term_taxonomy_id":2325,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":2324,"name":"#processanalyzer #processmonitoring #ramananalyzers #quality assurance #qualitycontrol #raman spectroscopy #raman #spectroscopy #pharmamanufacturing #pharma","slug":"processanalyzer-processmonitoring-ramananalyzers-quality-assurance-qualitycontrol-raman-spectroscopy-raman-spectroscopy-pharmamanufacturing-pharma","term_group":0,"term_taxonomy_id":2324,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19658,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/is-raman-spectroscopy-a-better-verification-method-in-pharmaceutical-manufacturing\/","url_meta":{"origin":17430,"position":0},"title":"Is Raman Spectroscopy a Better Verification Method in Pharmaceutical Manufacturing?","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Article Summary Verification testing is a critical step in pharmaceutical manufacturing, helping to ensure that every product released meets strict safety, quality, and regulatory standards. Verification helps ensure that products contain the correct active ingredients, meet concentration specifications, are free from contamination, and maintain structural and chemical integrity. This process\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Yellow pill and red check mark sitting on brown wood surface in front of abstract defocused background. Horizontal composition with selective focus and copy space. Front view. Drug approval concept.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19585,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/advanced-verification-in-pharmaceutical-manufacturing-using-raman-spectroscopy\/","url_meta":{"origin":17430,"position":1},"title":"Advanced Verification in Pharmaceutical Manufacturing Using Raman Spectroscopy","author":"Marlene Gasdia-Cochrane","date":"April 21, 2026","format":false,"excerpt":"Article Summary Pharmaceutical manufacturing relies on strict quality control to ensure that every product released to the market is safe, effective, and compliant with regulatory standards. Analytical testing plays a critical role in verifying product identity, composition, and consistency. Among modern analytical techniques, Raman spectroscopy stands out as a powerful\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Syringes, injection bottles and tablets lying on the table. Close-up, indoors, view from above. Day light, studio photo. Healthcare concept","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19168,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-dna-melting-analysis-using-uv-visible-spectroscopy\/","url_meta":{"origin":17430,"position":2},"title":"Understanding DNA Melting Analysis Using UV-Visible Spectroscopy","author":"Marlene Gasdia-Cochrane","date":"October 14, 2025","format":false,"excerpt":"DNA melting analysis is a vital molecular biology technique used to study the stability and properties of DNA by monitoring its transition from double-stranded to single-stranded form with increasing temperature. UV-visible spectroscopy measures changes in DNA absorbance during this process, providing insights into DNA stability, sequence composition, and molecular interactions.\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Close-up Of Dna Molecule On Blue Background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19538,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/why-continuous-real-time-raman-pat-outperforms-discrete-pat-in-bioprocessing\/","url_meta":{"origin":17430,"position":3},"title":"Why Continuous Real-Time Raman PAT Outperforms Discrete PAT in Bioprocessing","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"Overview Continuous, in-line, real-time process Raman spectroscopy significantly outperforms discrete PAT approaches in bioprocessing. By enabling deeper process understanding and proactive control, Raman spectroscopy can monitor upstream monoclonal antibody production through real-time measurements of glucose and lactate, which enables automated feedback control that significantly increased titer and reduced glycation (as\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"bioprocessing facility","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/cropped_1236x350.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/cropped_1236x350.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/cropped_1236x350.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/cropped_1236x350.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/cropped_1236x350.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19714,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/what-happens-to-your-raman-model-when-the-instrument-changes\/","url_meta":{"origin":17430,"position":4},"title":"What Happens to Your Raman Model When the Instrument Changes?","author":"Marlene Gasdia-Cochrane","date":"May 19, 2026","format":false,"excerpt":"Overview Raman spectroscopy is incredibly powerful for bioprocess monitoring. It gives you real-time visibility into what\u2019s happening inside a bioreactor\u2014no waiting, no guesswork, no relying solely on offline samples. But there\u2019s a practical question that doesn\u2019t get talked about enough: What happens to your analytical model when the instrument changes?\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Digital biotechnology concept. 3D render. - blue molecules","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/iStock-2193981513.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19801,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-process-analytical-technology-enables-real-time-quality-control-in-pharmaceutical-manufacturing\/","url_meta":{"origin":17430,"position":5},"title":"How Process Analytical Technology Enables Real-time Quality Control in Pharmaceutical Manufacturing","author":"Marlene Gasdia-Cochrane","date":"July 7, 2026","format":false,"excerpt":"Article Summary Process analytical technology (PAT) is transforming pharmaceutical manufacturing by enabling real-time monitoring, process understanding, and quality control throughout the production lifecycle. By combining advanced analytics, in-line sensors, data modeling, and automation, PAT helps manufacturers identify critical process parameters (CPPs), improve product quality, reduce deviations, and support real-time release\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"test tubes and pharmaceutical products","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/11\/iStock-1212392745.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=17430"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17430\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/17432"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=17430"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=17430"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=17430"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=17430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}