{"id":17474,"date":"2022-12-23T18:39:50","date_gmt":"2022-12-23T18:39:50","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=17474"},"modified":"2022-12-23T19:10:40","modified_gmt":"2022-12-23T19:10:40","slug":"cell-isolation-engineering-expansion","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/","title":{"rendered":"Cell isolation, engineering, and expansion"},"content":{"rendered":"<p><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\">This blogpost <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">serves as a<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> high-level <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">overview<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> of <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">common techniques employed in the field for cell isolation, genetic <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">modification<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> and approaches to<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> cell <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">expansion<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">.<\/span><strong><span class=\"NormalTextRun SCXW231754183 BCX8\"> For <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">a more in-depth discussion<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">, check out the <\/span><\/strong><\/span><strong><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW231754183 BCX8\">accompanying chapter<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">s<\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\"> on <\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun CommentStart SCXW231754183 BCX8\">cell isolation<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> (chapter <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">4<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">)<\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\">, <\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW231754183 BCX8\">engineering<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> (<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">chapter 5)<\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\">, and <\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW231754183 BCX8\">expansion<\/span><span class=\"NormalTextRun SCXW231754183 BCX8\"> (chapter 6<\/span><\/span><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\">) <\/span><span class=\"NormalTextRun SCXW231754183 BCX8\">in <\/span><span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW231754183 BCX8\">our<\/span> <\/span><a class=\"Hyperlink SCXW231754183 BCX8\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/cell-therapy-handbook.html?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"TextRun Underlined SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\" data-ccp-charstyle=\"Hyperlink\">Cell Therapy Handbook<\/span><\/span><\/a><span class=\"TextRun SCXW231754183 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW231754183 BCX8\">.<\/span><\/span><\/strong><span class=\"EOP SCXW231754183 BCX8\" data-ccp-props=\"{&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<h2><b><span data-contrast=\"none\">Cell Isolation<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"none\">At the foundation of any cell therapy development and manufacturing workflow, the quality of the starting cellular material directly impacts the final product and its efficacy of treatment. This section provides some insights into clinically relevant closed processes that can be used for the isolation of PBMCs and selection and activation of the T cell populations (CD3<\/span><span data-contrast=\"none\">+<\/span><span data-contrast=\"none\">).\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<h3><i><span data-contrast=\"none\">PMBC Isolation<\/span><\/i><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">While traditional density gradient centrifugation successfully isolates PBMCs from red blood cells, the pellet retains contaminants such as granulocytes, monocytes, and residual red blood cells. Additionally, most density gradient centrifugation isolations are performed using an open system\u2014which makes the procedure prone to errors, contamination, and user-to-user variability.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Another approach uses counterflow centrifugation, which separates cells based on their density as well as their size. Systems using this technology (e.g., <\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/clinical\/cell-gene-therapy\/manufacturing-solutions\/rotea-counterflow-centrifugation-system\/features.html?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\"><span data-contrast=\"none\">Gibco CTS Rotea system<\/span><\/a><span data-contrast=\"none\">) suspend cells in a fluidized bed by exerting a constant flow force against centrifugal forces. The suspended cells are gently concentrated without forming a densely packed pellet and can then be washed with very high recoveries. Using elutriation, dead cells can be removed to optimize viability of the population. Adjustments to centrifugal speed and flow rate allow for cells to be fractionated based on size and density, with minimal shear. Density gradient centrifugation and counterflow centrifugation produce comparable results <\/span><b><span data-contrast=\"none\">(Figure 1)<\/span><\/b><span data-contrast=\"none\">.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17475\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-1.-Closed-counterflow-centrifugation-system-versus-open-density-gradient-system-for-isolation-of-PBMCs-from-red-blood-cells.png\" alt=\"Figure 1. Closed counterflow centrifugation system versus open density gradient system for isolation of PBMCs from red blood cells\" width=\"614\" height=\"252\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-1.-Closed-counterflow-centrifugation-system-versus-open-density-gradient-system-for-isolation-of-PBMCs-from-red-blood-cells.png 614w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-1.-Closed-counterflow-centrifugation-system-versus-open-density-gradient-system-for-isolation-of-PBMCs-from-red-blood-cells-300x123.png 300w\" sizes=\"auto, (max-width: 614px) 100vw, 614px\" \/><\/p>\n<p><span class=\"TextRun SCXW246254534 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">Figure 1. Closed counterflow centrifugation system versus open density gradient system for isolation of PBMCs from red blood cells.<\/span><\/span><span class=\"TextRun SCXW246254534 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> A <\/span><span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">single-donor<\/span> <span class=\"NormalTextRun SpellingErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">leukopak<\/span><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> was divided into two, and PBMCs were separated using (A) density gradient centrifugation using <\/span><span class=\"NormalTextRun SpellingErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">Ficoll<\/span><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> polymer or (B) counterflow centrifugation using the CTS <\/span><span class=\"NormalTextRun SpellingErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">Rotea<\/span><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> system. The CTS <\/span><span class=\"NormalTextRun SpellingErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">Rotea<\/span><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> system can isolate PBMCs from a <\/span><span class=\"NormalTextRun SpellingErrorV2Themed SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\">leukopak<\/span><span class=\"NormalTextRun SCXW246254534 BCX8\" data-ccp-parastyle=\"Normal (Web)\"> in less than 30 minutes, with equivalent performance to the density gradient system and the added benefit of closed processing.<\/span><\/span><span class=\"EOP SCXW246254534 BCX8\" data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<h3><i><span data-contrast=\"none\">T cell Isolation and Activation<\/span><\/i><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">Following PBMC isolation, magnetic bead isolation and activation technology is an efficient and high-fidelity approach to this step. Magnetic beads conjugated to antibodies recognize specific T cell surface markers and bind to them. When placed near a magnet, the bead-T-cell complex binds and is held while unwanted cell types can then be washed away.\u00a0<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/clinical\/cell-gene-therapy\/cell-therapy\/cell-therapy-systems\/cell-therapy-systems-immunotherapy-tcell-dendritic-cell-products.html?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\"><span data-contrast=\"none\">Gibco CTS Dynabeads Magnetic Beads <\/span><span data-contrast=\"none\">CD3\/CD28<\/span><\/a><span data-contrast=\"none\"> provides both the primary and co-stimulatory signals required for activation and expansion of T-cells in a single step<\/span><span data-contrast=\"none\">, eliminating the need for a separate activation step<\/span><span data-contrast=\"none\">. <\/span><span data-contrast=\"auto\">For more details on this process, see<\/span> <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/isolation-activation-memory-t-cells-cts-dynabeads-cd3-cd28-application-note.pdf?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\"><i><span data-contrast=\"none\">One-step isolation and activation of naive and early memory T cells with CTS Dynabeads CD3\/CD28<\/span><\/i><span data-contrast=\"none\">.<\/span><\/a><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h2><b><span data-contrast=\"none\">Genome Engineering<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/h2>\n<h3><i><span data-contrast=\"none\">Gene editing technologies used to create allogeneic T cells<\/span><\/i><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"none\">Numerous genome engineering approaches exist and primarily fall into three gene editing tool classifications: zinc finger nuclease (ZFN), transcription activator-like effector nuclease (TALEN), and clustered regularly interspaced short palindromic repeat (CRISPR)-associated protein 9 (CRISPR-Cas9).\u00a0<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;335559738&quot;:0,&quot;335559739&quot;:300}\">\u00a0<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17476\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-2.-Gene-editing-tools-for-allogeneic-T-cells..png\" alt=\"Figure 2. Gene-editing tools for allogeneic T cells.\" width=\"545\" height=\"267\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-2.-Gene-editing-tools-for-allogeneic-T-cells..png 545w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Figure-2.-Gene-editing-tools-for-allogeneic-T-cells.-300x147.png 300w\" sizes=\"auto, (max-width: 545px) 100vw, 545px\" \/><\/p>\n<p><strong>Figure 2. Gene-editing tools for allogeneic T cells.<\/strong><\/p>\n<p>The two genome editing technologies, ZFN and TALEN, <strong>(Figures 2A and 2B)<\/strong> are very specific gene-editing tools because two DNA binding proteins-linked to nucleases (left- and right-handed complexes) must be designed for each editing experiment. The genetic sequences for these tools are transferred to a cell to be expressed into functional nucleases. More recently, CRISPR-Cas9 gene-editing technology derived from <em>Streptococcus pyogenes <\/em>has become available and is vastly different from both ZFN and TALEN gene-editing technologies. The CRISPR-Cas9 system <strong>(Figure 2C)<\/strong> simply requires the <em>in vitro<\/em> combination of the designed gRNA and the Cas9 protein to create a single CRISPR-Cas9 ribonucleoprotein (RNP) complex that can induce the double-stranded DNA break once it is delivered into a cell.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A36499?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\">Invitrogen TrueCut Cas9 Protein v2<\/a> is a next-generation CRISPR Cas9 protein engineered to deliver maximum editing efficiency\u2014featuring consistently high editing efficiency in all tested cell lines including standard, immune, primary, and stem.<\/p>\n<h3><em>Delivery Systems for Gene-editing Tools<\/em><\/h3>\n<p>Gene-editing tools tend to be macromolecules and thus require an active delivery system to get into target cells. Currently, numerous delivery systems are available for <em>in vivo<\/em> and <em>invitro<\/em> gene editing applications. These methods are summarized in the table below.<\/p>\n<h3><strong>Table 1. Delivery methods used for gene editing.<\/strong><\/h3>\n<table width=\"631\">\n<tbody>\n<tr>\n<td width=\"106\"><strong>Methods<\/strong><\/td>\n<td width=\"140\"><strong>Description<\/strong><\/td>\n<td width=\"148\"><strong>Advantages<\/strong><\/td>\n<td width=\"133\"><strong>Disadvantages<\/strong><\/td>\n<td width=\"104\"><strong>Examples<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"106\"><strong>Lentiviral vector<\/strong><\/td>\n<td width=\"140\">DNA\/RNA is packaged into the infectious viral particles and introduced into cells.<\/td>\n<td width=\"148\">High transduction efficiency; suitable for primary immune cells;<br \/>\nCAR T clinical usage precedent.<\/td>\n<td width=\"133\">Special lab environment needed; requires safety measures; labor intensive<\/td>\n<td width=\"104\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A4132602?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\">CTS LV-MAX<br \/>\n<\/a>LentiCRISPR<\/td>\n<\/tr>\n<tr>\n<td width=\"106\"><strong>Electroporation<\/strong><\/td>\n<td width=\"140\">Electrical pulse creates pores in the cell membrane, allowing the entry of DNA\/RNA\/RNP into the cell cytoplasm the nucleus.<\/td>\n<td width=\"148\">Fast and easy; large number of cells can be transfected in minutes.<\/td>\n<td width=\"133\">Requires special equipment; cytotoxic anions can form during the procedure, leading to cell death.<\/td>\n<td width=\"104\">Neon Transfection System<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/clinical\/cell-gene-therapy\/cell-therapy\/cell-therapy-manufacturing-solutions\/xenon-electroporation-system.html?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\">Xenon Electroporation System<br \/>\n<\/a>MaxCyte GT (Flow electroporation)<\/td>\n<\/tr>\n<tr>\n<td width=\"106\"><strong>Nucleofection<\/strong><\/td>\n<td width=\"140\">Similar to electroporation except the tools are delivered directly into the cell nucleus using very specific conditions provided by manufacturers.<\/td>\n<td width=\"148\">Effective for non-dividing cells; high throughput potential\u2013multiple samples can be transfected simultaneously.<\/td>\n<td width=\"133\">Requires special equipment; less flexible\u2013special protocols and reagents can&#8217;t be controlled by the user.<\/td>\n<td width=\"104\">Lonza Nucleofector System<\/td>\n<\/tr>\n<tr>\n<td width=\"106\"><strong>Cationic lipids<\/strong><\/td>\n<td width=\"140\">Positively charged liposomes encapsulate protein\/RNP and interact with negatively charged cell membrane facilitating entry into the cell cytoplasm via the endocytosis pathway.<\/td>\n<td width=\"148\">Easy and versatile (no special equipment), not very toxic, and can be a high throughput system.<\/td>\n<td width=\"133\">Lower transfection efficiency; not direct delivery into the nucleus; not applicable for all cell types.<\/td>\n<td width=\"104\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/CMAX00008?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\">Lipofectamine CRISPRMAX Cas9 Transfection Reagent<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><strong>Cell Expansion<\/strong><\/h2>\n<p>Following activation and engineering, buffer exchange can be done using counterflow centrifuge in a closed an automated manner. During expansion, release of immunostimulatory cytokines, such as IL-2 and IFN-\u0263 at desired levels can allow CD8<sup>+ <\/sup>cells to survive as memory T cells during expansion.<\/p>\n<p>The choice of media and supplements can significantly influence the growth of the T cell population, differentiation, viability, and the CD8:CD4 ratio during expansion. It is important to select a flexible expansion medium that is compatible with other workflow processes such as T cell isolation and activation, while being amendable to various platforms ranging from static cell culture systems to larger scale dynamic bioreactors.<\/p>\n<p><strong>[icon name=&#8221;readme&#8221; style=&#8221;brands&#8221; class=&#8221;&#8221; unprefixed_class=&#8221;&#8221;]\u00a0For more information on any of the cell therapy manufacturing techniques discussed above, check out the accompanying chapters 4,5, and 6 in our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/cell-therapy-handbook.html?cid=cdi_cgx_sbu_r01_co_cp1429_pjt7559_cgt000000_0so_blg_op_awa_og_s00_ctx-blog2\">Cell Therapy Handbook.<\/a><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This blogpost serves as a high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion. For a more in-depth discussion, check out the accompanying chapters on cell isolation (chapter 4), engineering (chapter 5), and expansion (chapter 6) in our Cell Therapy Handbook.\u00a0 Cell Isolation\u00a0 At the<\/p>\n","protected":false},"author":120,"featured_media":17479,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[2315,1087],"tags":[],"division":[],"class_list":{"0":"post-17474","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell-therapy","8":"category-pharmamfg","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Cell isolation, engineering, and expansion - Behind the Bench<\/title>\n<meta name=\"description\" content=\"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cell isolation, engineering, and expansion\" \/>\n<meta property=\"og:description\" content=\"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-23T18:39:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-23T19:10:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1773\" \/>\n\t<meta property=\"og:image:height\" content=\"1182\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Cell isolation, engineering, and expansion\",\"datePublished\":\"2022-12-23T18:39:50+00:00\",\"dateModified\":\"2022-12-23T19:10:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/\"},\"wordCount\":1074,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/12\\\/Scientist-using-Xenon-Electroporation-System.jpg\",\"articleSection\":[\"Cell Therapy\",\"Pharma &amp; Biotech Manufacturing\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/\",\"name\":\"Cell isolation, engineering, and expansion - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/12\\\/Scientist-using-Xenon-Electroporation-System.jpg\",\"datePublished\":\"2022-12-23T18:39:50+00:00\",\"dateModified\":\"2022-12-23T19:10:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/12\\\/Scientist-using-Xenon-Electroporation-System.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2022\\\/12\\\/Scientist-using-Xenon-Electroporation-System.jpg\",\"width\":1773,\"height\":1182},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/cell-isolation-engineering-expansion\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cell isolation, engineering, and expansion\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Cell isolation, engineering, and expansion - Behind the Bench","description":"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/","og_locale":"en_US","og_type":"article","og_title":"Cell isolation, engineering, and expansion","og_description":"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-12-23T18:39:50+00:00","article_modified_time":"2022-12-23T19:10:40+00:00","og_image":[{"width":1773,"height":1182,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Cell isolation, engineering, and expansion","datePublished":"2022-12-23T18:39:50+00:00","dateModified":"2022-12-23T19:10:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/"},"wordCount":1074,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","articleSection":["Cell Therapy","Pharma &amp; Biotech Manufacturing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/","name":"Cell isolation, engineering, and expansion - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","datePublished":"2022-12-23T18:39:50+00:00","dateModified":"2022-12-23T19:10:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Read the high-level overview of common techniques employed in the field for cell isolation, genetic modification and approaches to cell expansion.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","width":1773,"height":1182},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cell-isolation-engineering-expansion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Cell isolation, engineering, and expansion"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":2315,"label":"Cell Therapy"},{"value":1087,"label":"Pharma &amp; Biotech Manufacturing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System-1024x683.jpg",760,507,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":2315,"name":"Cell Therapy","slug":"cell-therapy","term_group":0,"term_taxonomy_id":2315,"taxonomy":"category","description":"","parent":0,"count":24,"filter":"raw","meta":[],"cat_ID":2315,"category_count":24,"category_description":"","cat_name":"Cell Therapy","category_nicename":"cell-therapy","category_parent":0},{"term_id":1087,"name":"Pharma &amp; Biotech Manufacturing","slug":"pharmamfg","term_group":0,"term_taxonomy_id":1087,"taxonomy":"category","description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","parent":0,"count":62,"filter":"raw","meta":[],"cat_ID":1087,"category_count":62,"category_description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","cat_name":"Pharma &amp; Biotech Manufacturing","category_nicename":"pharmamfg","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19184,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/magnetic-cell-separation-how-to-automate-cell-isolation\/","url_meta":{"origin":17474,"position":0},"title":"Magnetic Cell Separation: How to Automate Cell Isolation","author":"Behind The Bench Staff","date":"October 29, 2025","format":false,"excerpt":"In the rapidly advancing field of medical diagnostics, liquid biopsy stands out as an innovative technique that is advancing the way we detect and monitor diseases. Unlike traditional biopsies, which require invasive procedures to extract tissue samples, liquid biopsy offers a minimally invasive alternative by isolating cells from complex samples\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Automated cell isolation","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19837,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/managing-formulation-fill-finish-in-the-car-t-cell-manufacturing-process\/","url_meta":{"origin":17474,"position":1},"title":"Managing Formulation, Fill &amp; Finish in the CAR T-Cell Manufacturing Process","author":"Behind The Bench Staff","date":"July 28, 2026","format":false,"excerpt":"Chimeric antigen receptor (CAR)-T cell therapies represent a paradigm shift in medicine, offering personalized, potentially curative treatments for cancer and other serious diseases. Unlike traditional biologics, CAR T-cell products are living therapeutics. Highly sensitive cells whose quality, safety, and efficacy depend on careful handling at every step of the manufacturing\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Scientist working in a lab","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19697,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/allogeneic-cell-therapies-enhancing-patient-access-via-off-the-shelf-options\/","url_meta":{"origin":17474,"position":2},"title":"Allogeneic cell therapies: Enhancing patient access via off-the-shelf options","author":"Behind The Bench Staff","date":"May 16, 2026","format":false,"excerpt":"Chimeric Antigen Receptor (CAR) T cell therapy has transformed treatment paradigms for hematologic malignancies. However, most FDA-approved CAR-T cell therapies today are autologous, meaning they are manufactured individually from each patient\u2019s own T cells. While effective, this approach presents significant manufacturing constraints, including long timelines, dependence on patient health for\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"CTx Feature Image","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19392,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/raw-material-considerations-for-cell-therapy-manufacturing\/","url_meta":{"origin":17474,"position":3},"title":"Raw material considerations for cell therapy manufacturing","author":"Behind The Bench Staff","date":"February 12, 2026","format":false,"excerpt":"In cell therapy manufacturing, the lack of definitive regulatory frameworks often makes the process of selecting and qualifying raw materials complex and unclear. In this blog post, we will explore the key considerations for choosing raw materials in cell therapy manufacturing and the importance of early selection in ensuring production\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19257,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cryopreservation-advancements-in-human-stem-cell-derived-neurons\/","url_meta":{"origin":17474,"position":4},"title":"Cryopreservation: Advancements in Human Stem Cell-Derived Neurons","author":"Behind The Bench Staff","date":"December 3, 2025","format":false,"excerpt":"The field of cryopreservation has seen advancements, particularly with the ability to preserve human stem cell-derived neurons. This progress holds great promise for research and therapeutic applications, helping to ensure the availability of high-quality neuronal cultures. What is Cryopreservation? Cryopreservation involves cooling cells to sub-zero temperatures to halt biological activity\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Illustration of active nerve cell synapses showing neural connections, related to cryopreservation research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19755,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/deterministic-programming-ipsc-disease-modeling\/","url_meta":{"origin":17474,"position":5},"title":"Finding the \u201cCheat Codes\u201d to Cell Identity: Deterministic Programming of iPSCs","author":"Ashleigh Barlow","date":"May 15, 2026","format":false,"excerpt":"Article Summary Fiona Connolly, formerly Platform Innovation and Automation Scientist at bit.bio, joins Absolute Gene-ius to discuss how deterministic programming is reshaping stem cell biology, disease modeling, and drug discovery. With a background spanning molecular biology, cell engineering, and automation, Fiona brings a unique perspective on how genetic \u201ccheat codes\u201d\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Portrait of Fiona Connolly speaking on stem cell engineering and deterministic programming technologies.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2022\/12\/Scientist-using-Xenon-Electroporation-System.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17474","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=17474"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17474\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/17479"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=17474"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=17474"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=17474"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=17474"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}