{"id":17833,"date":"2023-05-01T19:47:54","date_gmt":"2023-05-01T19:47:54","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?p=17833"},"modified":"2023-05-12T21:45:40","modified_gmt":"2023-05-12T21:45:40","slug":"choosing-a-genetic-analysis-method-for-your-research-laboratory","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/","title":{"rendered":"Choosing a genetic analysis method for your research laboratory"},"content":{"rendered":"<p>Technological advances in genetic analysis methods have greatly expanded cytogenetic analysis options in recent years, pushing the boundaries of what is practical and possible in clinical research settings. These advances have made numerous kinds of genetic abnormalities increasingly simple to recognize.<\/p>\n<p>With this proliferation of methods comes a new challenge for researchers: selecting the most optimal method for their research laboratory. Choosing between the many options currently available is no small task. This rundown provides the basics of the most common options.<\/p>\n<h2>Comparison of genetic analysis methods<\/h2>\n<p>Current methods of chromosomal analysis fall into two broad categories: <strong>chromosomal microarrays<\/strong> and <strong>next-generation sequencing<\/strong>.<\/p>\n<h3><span lang=\"EN-CA\">Chromosomal microarrays<\/span><\/h3>\n<p>Chromosomal microarray analysis (CMA) is widely used to study specific chromosomal aberrations. This genetic analysis method typically consists of a solid matrix carrying a defined set of nucleic acid fragments that serve as probes for their DNA complements. DNA from a sample, typically labeled with fluorescent tags, is allowed to hybridize, or not, with the probes and the excess is washed away.<\/p>\n<p>The fluorescence that persists after this wash shows which probe sequences on the microarray are present in the sample and in what relative quantities. CMA is especially well-suited to detecting copy-number variations (CNVs), which are variations in the number of copies of a genomic region of interest, but can also detect single-nucleotide variations (SNVs), which are single-base-pair differences.<\/p>\n<p>User-friendly and flexible analysis software interpreting and reporting the results of CMA are standardized and readily available. Combined with the relative versatility and ease of use of CMA in general and the versatile analysis software available for this technique, CMA is a powerful genetic analysis tool.<\/p>\n<p>The most advanced arrays are hybrid-SNP arrays which combine the best features of aCGH and SNP arrays. These are high-resolution and high-density with up to seven million polymorphic (SNP) and non-polymorphic (copy number) probes. These higher-density arrays give greater confidence to accurately identify copy-neutral aberrations compared to non-hybrid arrays. This makes these arrays especially well-suited to genomic abnormalities that often elude other sorts of arrays, including mosaicism, triploidy, and consanguinity.<\/p>\n<h3><span lang=\"EN-CA\">Next-generation sequencing<\/span><\/h3>\n<p>When further insight is needed, next-generation sequencing (NGS) can be paired with CMA or used separately. Regardless of the specifics, next-generation sequencing works in broadly the same way.<\/p>\n<p>First, a genome is fragmented into a library of pieces and amplified.<\/p>\n<p>Then, those pieces are sequenced and digitally reassembled using software. Sequencing with fragments rather than the whole, intact genome enables the wet-lab portion of a sequencing event to be done massively in parallel, making NGS much faster than some methods. By comparing the results of NGS to a reference genome, aberrations of interest can be flagged en masse, be they deletions, insertions, duplications, or something else.<\/p>\n<p>The digital tools available for use with NGS continue to improve, making this technique more and more useful for more and more complex genomic situations. NGS can be done at the level of the entire genome, but it can also be performed specifically on the collected body of exons, the exome, for <em>exome sequencing. <\/em>Exome sequencing is much faster and less expensive than whole-genome sequencing but might miss aberrations associated with non-coding DNA, which is the majority of all DNA. NGS is typically the province of bioinformaticians and not something a laboratory can pick up without dedicated expertise.<\/p>\n<h2><span lang=\"EN-CA\">Recommendations for choosing a genetic analysis method<\/span><\/h2>\n<p>Professional societies keep their own counsel regarding genomic analysis methods. Most societies including American College of Genetics (ACMG) and American College of Obstetricians and Gynecologists (ACOG) recommend CMA to study genetic disorders or reveal that a situation is complex enough to warrant NGS.<\/p>\n<p>Which genetic analysis technology is the optimal choice for a given research laboratory depends on numerous factors, including but not limited to:<\/p>\n<ul>\n<li><em>Data quality,<\/em> which is affected by the kinds of aberrations one is interested in exploring and, from there, which analytical methods best illuminate those specific differences.<\/li>\n<li><em>Resources, <\/em>which include ability to store the large amount of data some methods generate, space for laboratory instruments, funds for procuring instruments and reagents, and ability to hire and retain bioinformatics expertise.<\/li>\n<li><em>Time, <\/em>in particular the desired turnaround time for results. Some methods are faster than others and some samples prioritize speed more than others, such as prenatal genetic prenatal genetic research.<\/li>\n<li><em>Cost, <\/em>which is affected by throughput for all methods. NGS is more expensive than chromosomal microarrays in general and can only approach the cost per sample of microarrays with very high throughput.<\/li>\n<li><em>Technical considerations, <\/em>in particular whether a research laboratory has the expertise to sort through potentially superfluous findings in a high-data method to find variations of interest.<\/li>\n<\/ul>\n<h3>Combining analysis methods for comprehensive genomic research<\/h3>\n<p>Often, the best course of action is to use relatively inexpensive analysis methods as an initial effort and add other analysis tools as needed to clarify or augments the results thereof. In this way, the most expensive, time-consuming, and difficult-to-process methods are reserved for situations that justify their outlay. Combining analysis methods from the start, such as using well-chosen CMA alongside whole-genome sequencing, can also yield a large amount of data quickly and help research difficult cases faster than doing analyses in sequence, but requires a research laboratory with substantial resources.<\/p>\n<h2><span lang=\"EN-CA\">Conclusion<\/span><\/h2>\n<p>CMA and NGS are both powerful genomic analysis methods with a variety of sub-methods. Studying chromosomal aberrations can work with any of these methods, but each one is best suited to specific situations. Chromosomal microarrays are an established, robust, low-resource technique that is also more limited than NGS and choosing a specific kind of microarray can be tricky when they all work differently. Conversely, NGS is a powerful method that is expensive and time-consuming to implement and generates an enormous amount of potentially superfluous data to sort through, requiring expertise to use well. Many use cases benefit from combining methods. The decision of which method or methods to use depends on the particulars of a given research laboratory\u2019s use case and can only ever be an individual choice. There is no one-size-fits-all method, but between them all, most can be accommodated.<\/p>\n<p>For more information about chromosomal analysis methods and how to choose between them, <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/clinical\/constitutional-genetic-testing.html\" target=\"_blank\" rel=\"noopener\">download our latest white paper.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technological advances in genetic analysis methods have greatly expanded cytogenetic analysis options in recent years, pushing the boundaries of what is practical and possible in clinical research settings. These advances have made numerous kinds of genetic abnormalities increasingly simple to recognize. With this proliferation of methods comes a new challenge for researchers: selecting the most<\/p>\n","protected":false},"author":120,"featured_media":17870,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[265],"tags":[2294,2277,6,12],"division":[],"class_list":{"0":"post-17833","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-consumer-genetics","8":"tag-genetic-analysis","9":"tag-microarray","10":"tag-next-generation-sequencing","11":"tag-ngs","12":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Choosing a genetic analysis method for your research laboratory<\/title>\n<meta name=\"description\" content=\"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Choosing a genetic analysis method for your research laboratory\" \/>\n<meta property=\"og:description\" content=\"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-01T19:47:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-05-12T21:45:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Choosing a genetic analysis method for your research laboratory\",\"datePublished\":\"2023-05-01T19:47:54+00:00\",\"dateModified\":\"2023-05-12T21:45:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/\"},\"wordCount\":1032,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/05\\\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg\",\"keywords\":[\"genetic analysis\",\"microarray\",\"Next Generation Sequencing\",\"NGS\"],\"articleSection\":[\"Consumer Genetics\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/\",\"name\":\"Choosing a genetic analysis method for your research laboratory\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/05\\\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg\",\"datePublished\":\"2023-05-01T19:47:54+00:00\",\"dateModified\":\"2023-05-12T21:45:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/05\\\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/05\\\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg\",\"width\":1200,\"height\":628},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/choosing-a-genetic-analysis-method-for-your-research-laboratory\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing a genetic analysis method for your research laboratory\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Choosing a genetic analysis method for your research laboratory","description":"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/","og_locale":"en_US","og_type":"article","og_title":"Choosing a genetic analysis method for your research laboratory","og_description":"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2023-05-01T19:47:54+00:00","article_modified_time":"2023-05-12T21:45:40+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_description":"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Choosing a genetic analysis method for your research laboratory","datePublished":"2023-05-01T19:47:54+00:00","dateModified":"2023-05-12T21:45:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/"},"wordCount":1032,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","keywords":["genetic analysis","microarray","Next Generation Sequencing","NGS"],"articleSection":["Consumer Genetics"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/","name":"Choosing a genetic analysis method for your research laboratory","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","datePublished":"2023-05-01T19:47:54+00:00","dateModified":"2023-05-12T21:45:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Discover the benefits, costs, and considerations to enhance your research with the perfect genetic analysis method for your lab.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","width":1200,"height":628},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/choosing-a-genetic-analysis-method-for-your-research-laboratory\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Choosing a genetic analysis method for your research laboratory"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":265,"label":"Consumer Genetics"}],"post_tag":[{"value":2294,"label":"genetic analysis"},{"value":2277,"label":"microarray"},{"value":6,"label":"Next Generation Sequencing"},{"value":12,"label":"NGS"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1-1024x536.jpg",760,398,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":265,"name":"Consumer Genetics","slug":"consumer-genetics","term_group":0,"term_taxonomy_id":265,"taxonomy":"category","description":"","parent":0,"count":9,"filter":"raw","meta":[],"cat_ID":265,"category_count":9,"category_description":"","cat_name":"Consumer Genetics","category_nicename":"consumer-genetics","category_parent":0}],"tag_info":[{"term_id":2294,"name":"genetic analysis","slug":"genetic-analysis","term_group":0,"term_taxonomy_id":2294,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]},{"term_id":2277,"name":"microarray","slug":"microarray","term_group":0,"term_taxonomy_id":2277,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":6,"name":"Next Generation Sequencing","slug":"next-generation-sequencing","term_group":0,"term_taxonomy_id":6,"taxonomy":"post_tag","description":"","parent":0,"count":171,"filter":"raw","meta":[]},{"term_id":12,"name":"NGS","slug":"ngs","term_group":0,"term_taxonomy_id":12,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":17833,"position":0},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19997,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ai-laboratory-automation-qpcr\/","url_meta":{"origin":17833,"position":1},"title":"AI and Laboratory Automation: The experimental context behind qPCR data","author":"Behind The Bench Staff","date":"September 11, 2026","format":false,"excerpt":"AI is changing how researchers analyze biological data, while automation is changing how that data is performed at scale. As more of the research process becomes automated and data-driven, an important question emerges: What should researchers consider about how data is generated before downstream analysis begins? In qPCR, assays, reagents,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"qPCR reaction tube with amplification curves representing experimental data used in AI and laboratory automation.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19223,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/innovations-in-qpcr-technology\/","url_meta":{"origin":17833,"position":2},"title":"Innovations in qPCR Technology: What Researchers Need to Know","author":"Ashleigh Barlow","date":"October 29, 2025","format":false,"excerpt":"https:\/\/youtu.be\/z9Kb1xAnNcg?si=TVUIc8rUxZUOhCqA Real-time PCR, also known as quantitative polymerase chain reaction (qPCR) technology, has been a cornerstone of molecular biology research for decades. With continuous advancements, qPCR remains a critical tool for researchers worldwide. Damien Luk, Senior Director of Product Management at Thermo Fisher Scientific, shared his insights on the future\u2026","rel":"","context":"In &quot;Developmental Biology&quot;","block_context":{"text":"Developmental Biology","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/developmental-biology\/"},"img":{"alt_text":"A lineup of Thermo Fisher Scientific QuantStudio real-time PCR systems, including QuantStudio 3, 5, 6 Pro, 7 Pro, and 12K Flex instruments, displayed against a blue gradient background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":17833,"position":3},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19883,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/building-a-better-sample-qc-workflow-from-extraction-to-sequencing\/","url_meta":{"origin":17833,"position":4},"title":"Building a Better Sample QC Workflow: From Extraction to Sequencing","author":"Marlene Gasdia-Cochrane","date":"August 25, 2026","format":false,"excerpt":"Article Summary Successful genomics experiments don't begin with sequencing\u2014they begin with sample quality. Every downstream application, from PCR to next-generation sequencing (NGS), depends on starting with nucleic acids that are accurately quantified and free from contaminants that could compromise results. Establishing a consistent quality control workflow helps laboratories improve reproducibility\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"A pipette drops a liquid into a petri dish with a dna sequence background, science concept. It suggests medical or genetic research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19168,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-dna-melting-analysis-using-uv-visible-spectroscopy\/","url_meta":{"origin":17833,"position":5},"title":"Understanding DNA Melting Analysis Using UV-Visible Spectroscopy","author":"Marlene Gasdia-Cochrane","date":"October 14, 2025","format":false,"excerpt":"DNA melting analysis is a vital molecular biology technique used to study the stability and properties of DNA by monitoring its transition from double-stranded to single-stranded form with increasing temperature. UV-visible spectroscopy measures changes in DNA absorbance during this process, providing insights into DNA stability, sequence composition, and molecular interactions.\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Close-up Of Dna Molecule On Blue Background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/05\/PG2604-PJT8536-COL119693-CMA-NGS-White-Paper-Banners-Global-F_Social-2-1200x628_0002_Layer-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17833","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=17833"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17833\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/17870"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=17833"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=17833"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=17833"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=17833"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}