{"id":17970,"date":"2023-07-17T23:26:51","date_gmt":"2023-07-17T23:26:51","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=17970"},"modified":"2023-07-18T16:00:41","modified_gmt":"2023-07-18T16:00:41","slug":"mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/","title":{"rendered":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics"},"content":{"rendered":"<h2>Changing the narrative with proactive surveillance using advanced diagnostics<\/h2>\n<p>While the global livestock industry is trying to reduce the use of antibiotics, it\u2019s time for a fresh look at mastitis and how to keep it out of your herd. One option to consider is more advanced diagnostics, like qPCR testing, which is offering producers an opportunity to be proactive with their herds\u2014to directly monitor the specific mastitis pathogen loads on their dairy farms so they treat only known mastitis infections with the right antibiotic.<\/p>\n<h3>Cost of mastitis<\/h3>\n<p>Mastitis is estimated to cost the global dairy industry $19.7\u2013$32 billion annually, and the cost of subclinical mastitis in the US alone is expected to exceed $1 billion annually [1]. While the economic impact varies by country, a mastitis case often costs $250 to $500 per clinical case and $100 per subclinical case [2]. Clinical and subclinical cases often result in reduced milk yield and quality, decreased lactation potential, and early culling of lactating cows.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-17972 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/clinical-mastitis-costs.png\" alt=\"The costs of mastitis, resulting in a reduced milk yield and quality, reduced lactation persistency, and early culling.\" width=\"780\" height=\"170\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/clinical-mastitis-costs.png 780w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/clinical-mastitis-costs-300x65.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/clinical-mastitis-costs-768x167.png 768w\" sizes=\"auto, (max-width: 780px) 100vw, 780px\" \/><br \/>\nPrudent use of antibiotics can reduce duration of treatment, labor, cost of antibiotics, and the likelihood of pathogen resistance, which can help minimize the economic impact of mastitis on your dairy.<\/p>\n<h3>Gram-positive and gram-negative mastitis and mycoplasmas<\/h3>\n<p>The basic difference in categories of mastitis pathogens is their physiology or cell structure. Gram-positive mastitis bacteria have a thick cell wall but don\u2019t have a protective outer cell membrane. The cell wall\u2019s membrane is highly selective about how and what components move in and out. Gram-negative mastitis bacteria have a thin cell wall with two membranes that are somewhat selective, and the outer membrane protects the cell wall. Penicillin antibiotics must attack the cell wall to be effective. As a result, gram-positive bacteria tend to be more susceptible to penicillin antibiotics, and gram-negative bacteria are more resistant.<\/p>\n<p>Mycoplasmas do not have a cell wall. They only have a cell membrane, making them much more resistant to antibiotics because there&#8217;s no cell wall to attack.<\/p>\n<h3>Selective dry cow therapy<\/h3>\n<p>Many dairy farms around the world are shifting to selective dry cow therapy (SDCT) to reduce the use of broad-spectrum antibiotics by targeting only cows with known intramammary infections. Previously, at dry-off cows were treated every quarter with antibiotics, regardless of whether or not the animals were infected with mastitis or their somatic cell count (SCC) score.<\/p>\n<p>In 2022, the European Union (EU) banned the use of blanket dry cow therapy (some EU countries banned it earlier) and turned to SDCT. The EU\u2019s goal is to reduce antibiotic therapy use. A 2021 systemic review and meta-analysis showed SDCT can reduce antibiotics at dry-off by 66% [3]. However, from a producer\u2019s perspective, the success of dry-off is important to help ensure healthy cows and increased milk production during a cow\u2019s second and third lactations.<\/p>\n<div id=\"attachment_17973\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17973\" class=\"size-large wp-image-17973\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves-1024x620.png\" alt=\"A chart showing an increase in profits from higher lactation persistency.\" width=\"760\" height=\"460\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves-1024x620.png 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves-300x182.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves-768x465.png 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves-1536x931.png 1536w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/lactaction-curves.png 1837w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-17973\" class=\"wp-caption-text\">Figure 1. Typical Holstein lactation curves and measure of lactation persistency.<br \/>Lactanet, 2017. Increased Profits from Higher Lactation Persistency. lactanet.ca\/en\/increased-profits-from-higher-lactation-persistency\/. Figure used with permission from Lactanet Canada.<\/p><\/div>\n<p>SDCT does take a higher level of management to keep mastitis and SCC levels low. Maintaining proper hygiene in the milking parlor is a critical factor to SDCT success. Understanding the pathogen load on your dairy is also very important.<\/p>\n<p>Molecular diagnostic tools can give producers more granular answers about the types of pathogens that are present in udder infections, versus just knowing that there&#8217;s some inflammation process going on due to infections, which is the answer that SCC scores provide. qPCR testing is an efficient and accurate way to quickly determine pathogen type and gram-positive and gram-negative strains.<\/p>\n<h3>Testing and herd surveillance<\/h3>\n<p>Since mastitis can cause significant economic losses year over year, dairy producers should monitor SCC regularly and the milking team should check cows\u2019 milk and udders during their milking routine. Fast, accurate diagnostic results are needed to identify the mastitis-causing pathogen(s) so that the dairy producer and veterinarian can quickly develop an action plan to minimize loss of milk, duration of treatments, and spread of disease to the rest of the herd.<\/p>\n<p>Once mastitis has been identified in a cow\u2019s quarters, it is important to test the milk because different categories of pathogens require different management strategies. Several diagnostic testing options are available. It\u2019s best to consider the needs of your dairy farm, and then work with your herd veterinarian to develop a mastitis control program that fits your specific operation.<\/p>\n<div id=\"attachment_17975\" style=\"width: 478px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17975\" class=\"size-full wp-image-17975\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png\" alt=\"A chart showing that Multiplex PCR provides detailed information from different sample types quickly and reliably.\" width=\"468\" height=\"223\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png 468w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing-300x143.png 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><p id=\"caption-attachment-17975\" class=\"wp-caption-text\">Table 1. List of diagnostic tests to identify mastitis.<\/p><\/div>\n<p>Bacterial culture has traditionally been used in many parts of the world for the diagnosis of mastitis infections. However, culturing can take up to 10 days. When the diagnostician views the culture plate, it may be overgrown with other bacteria, making it difficult to recognize the specific pathogen that is being looked for.<\/p>\n<p>With culture, it\u2019s possible for a few pathogens to grow large colonies that dominate the dish, prohibiting the growth of other pathogens. Unfortunately, fast-growing pathogens aren\u2019t necessarily the most important or the only pathogens to target. Knowing and understanding the full pathogen load is often critical to resolving a high mastitis infection rate in the herd. Mixed infections of two or more mastitis pathogens have been detected more commonly by qPCR than by conventional culture [4].<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-17974 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-test-process.png\" alt=\"\" width=\"936\" height=\"234\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-test-process.png 936w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-test-process-300x75.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-test-process-768x192.png 768w\" sizes=\"auto, (max-width: 936px) 100vw, 936px\" \/><\/p>\n<h4>Advantages of qPCR Testing for Mastitis Detection<\/h4>\n<p>About 40% of clinically abnormal milk samples tested by traditional bacterial culture come back with a \u201cno growth\u201d result, often leaving dairy producers right where they started\u2014with a mastitic cow and no diagnosis for accurate treatment.<\/p>\n<p>Real-time qPCR technology detects pathogens by targeting a pathogen-specific (bacterial or viral) nucleic acid sequence within a sample containing nucleic acid from an animal. It essentially detects pathogens by amplifying small amounts of DNA in samples that contain live or dead cells. This also means qPCR can show a history of infection even if it has been resolved. The high sensitivity of this technology enables detection of pathogens even before clinical signs might present themselves, thus allowing for quicker action to separate and quarantine sick animals while keeping the rest of the herd healthy.<\/p>\n<p>Due to its sensitivity and specificity, qPCR detects more pathogens per sample and more minor pathogens compared to culture. PCR provides clear and objective results, which allow veterinarians and producers to make informed decisions to create targeted treatments that can minimize the use of antibiotics. Results from qPCR are usually available the same day and provide a highly accurate positive or negative outcome with low levels of false-positive or false-negative results.<\/p>\n<p>qPCR also offers dairy producers more flexibility to store milk samples until they can get them to a laboratory and samples can be pooled for more cost-effective screening. qPCR can be used with individual cow samples or bulk milk samples, which can be fresh, frozen, or preserved. With culture, milk samples must be fresh.<\/p>\n<h3>qPCR more accurately detects mastitis pathogens<\/h3>\n<p>qPCR kits, such as the Applied Biosystems\u2122 VetMAX\u2122 MastiType Multi Combo Kit, offer laboratory results in 2.5\u20133 hours, enabling same-day results even for <em>Mycoplasma<\/em> species.<\/p>\n<p>The kit is designed to detect 15 mastitis-causing bacteria and an antibiotic resistance gene with just one diagnostic test. It facilitates reliable results with individual cow samples or bulk milk samples, which can be fresh, frozen, or preserved.<\/p>\n<p>VetMAX MastiType multiplex qPCR kits accurately detect mastitis-causing pathogens, allowing the veterinarian to recommend the appropriate treatment protocol and use antibiotics only when needed.<\/p>\n<p>Laboratories can also benefit from the VetMAX kit\u2019s fast and convenient workflow using the Applied Biosystems\u2122 MagMAX\u2122 CORE nucleic acid extraction system. It also uses Applied Biosystems\u2122 QuantStudio\u2122 5 real-time PCR instrumentation, which employs cloud-based software solutions.<\/p>\n<p><a href=\"http:\/\/thermofisher.com\/mastitis\" target=\"_blank\" rel=\"noopener\">Learn more about our full mastitis workflow solutions.<\/a><\/p>\n<h3>References<\/h3>\n<ol>\n<li>Rollin E et al. (2015) The cost of clinical mastitis in the first 30 days of lactation: an economic modeling tool. <em>Prev Vet Med.<\/em> 122(3):257\u2013264. doi:10.1016\/j.prevetmed.2015.11.006.<\/li>\n<li>Bovine diagnostics: How much does mastitis cost dairy producers annually? (2023). <a href=\"https:\/\/www.thecattlesite.com\/focus\/thermo-fisher-scientific\/2335\/bovine-diagnostics-how-much-does-mastitis-cost-dairy-producers-annually\">https:\/\/www.thecattlesite.com\/focus\/thermo-fisher-scientific\/2335\/bovine-diagnostics-how-much-does-mastitis-cost-dairy-producers-annually<\/a>.<\/li>\n<li>Fid\u00e8le K et al. (2021) Comparing blanket vs. selective dry cow treatment approaches for elimination and prevention of intramammary infections during the dry period: a systematic review and meta-analysis. <em>Front Vet Sci.<\/em> 8:688450. doi:10.3389\/fvets.2021.688450.<\/li>\n<li>Keane OM et al. (2013) Increased detection of mastitis pathogens by real-time PCR compared to bacterial culture. <em>Vet Rec.<\/em> 173(11):268. doi: 10.1136\/vr.101598.<\/li>\n<\/ol>\n<p><strong>For Veterinary Use Only. For <em>In Vitro<\/em> Use Only. Regulatory requirements vary by country, products may not be available in your geographical area.<\/strong> \u00a9 2023 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Changing the narrative with proactive surveillance using advanced diagnostics While the global livestock industry is trying to reduce the use of antibiotics, it\u2019s time for a fresh look at mastitis and how to keep it out of your herd. One option to consider is more advanced diagnostics, like qPCR testing, which is offering producers an<\/p>\n","protected":false},"author":120,"featured_media":17975,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[83],"tags":[2233,2351,43],"division":[],"class_list":{"0":"post-17970","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-animal-health-and-agrigenomics","8":"tag-animal-health","9":"tag-bovine-health","10":"tag-pcr","11":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics<\/title>\n<meta name=\"description\" content=\"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics\" \/>\n<meta property=\"og:description\" content=\"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-17T23:26:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-18T16:00:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png\" \/>\n\t<meta property=\"og:image:width\" content=\"468\" \/>\n\t<meta property=\"og:image:height\" content=\"223\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics\",\"datePublished\":\"2023-07-17T23:26:51+00:00\",\"dateModified\":\"2023-07-18T16:00:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/\"},\"wordCount\":1425,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/07\\\/mastitis-testing.png\",\"keywords\":[\"animal health\",\"bovine health\",\"PCR\"],\"articleSection\":[\"Animal Health and AgriGenomics\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/\",\"name\":\"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/07\\\/mastitis-testing.png\",\"datePublished\":\"2023-07-17T23:26:51+00:00\",\"dateModified\":\"2023-07-18T16:00:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/07\\\/mastitis-testing.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/07\\\/mastitis-testing.png\",\"width\":468,\"height\":223,\"caption\":\"Table 1. List of diagnostic tests to identify mastitis.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics","description":"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/","og_locale":"en_US","og_type":"article","og_title":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics","og_description":"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2023-07-17T23:26:51+00:00","article_modified_time":"2023-07-18T16:00:41+00:00","og_image":[{"width":468,"height":223,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","type":"image\/png"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_description":"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics","datePublished":"2023-07-17T23:26:51+00:00","dateModified":"2023-07-18T16:00:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/"},"wordCount":1425,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","keywords":["animal health","bovine health","PCR"],"articleSection":["Animal Health and AgriGenomics"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/","name":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","datePublished":"2023-07-17T23:26:51+00:00","dateModified":"2023-07-18T16:00:41+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Proactive surveillance with qPCR testing transforms mastitis control, reducing antibiotic usage and improving herd health in dairy cows.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","width":468,"height":223,"caption":"Table 1. List of diagnostic tests to identify mastitis."},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mastitis-is-the-1-reason-dairy-cows-are-treated-with-antibiotics\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Mastitis is the #1 Reason Dairy Cows are Treated with Antibiotics"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":83,"label":"Animal Health and AgriGenomics"}],"post_tag":[{"value":2233,"label":"animal health"},{"value":2351,"label":"bovine health"},{"value":43,"label":"PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png",468,223,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":1,"category_info":[{"term_id":83,"name":"Animal Health and AgriGenomics","slug":"animal-health-and-agrigenomics","term_group":0,"term_taxonomy_id":83,"taxonomy":"category","description":"","parent":0,"count":65,"filter":"raw","meta":[],"cat_ID":83,"category_count":65,"category_description":"","cat_name":"Animal Health and AgriGenomics","category_nicename":"animal-health-and-agrigenomics","category_parent":0}],"tag_info":[{"term_id":2233,"name":"animal health","slug":"animal-health","term_group":0,"term_taxonomy_id":2233,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]},{"term_id":2351,"name":"bovine health","slug":"bovine-health","term_group":0,"term_taxonomy_id":2351,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":43,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":43,"taxonomy":"post_tag","description":"","parent":0,"count":142,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19345,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/precision-oncology-diagnostics\/","url_meta":{"origin":17970,"position":0},"title":"The Expanding Role of Molecular Diagnostics in Precision Oncology","author":"Behind The Bench Staff","date":"January 13, 2026","format":false,"excerpt":"https:\/\/www.youtube.com\/watch?v=F6FfHIizJBY For Dr. Harald Bartsch, a clinical pathologist in southern Bavaria, molecular diagnostic tools have become an indispensable part of his arsenal. \u201cI believe molecular diagnostics play a crucial role in modern oncology, and I see this as the direction everything is headed,\u201d says Dr. Bartsch. While immunohistochemistry remains central\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Clinical Pathologist in a Molecular Diagnostics Laboratory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19676,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/avian-influenza-qpcr-assay-failure\/","url_meta":{"origin":17970,"position":1},"title":"Avian Influenza qPCR Testing: How Viral Evolution Contributes to Assay Failure\u2014and How Labs Can Stay Ahead","author":"Behind The Bench Staff","date":"May 1, 2026","format":false,"excerpt":"Molecular veterinary diagnostic laboratories rely on reverse transcriptase real-time PCR (RT qPCR) assays to detect avian influenza virus (AIV) quickly and accurately. These assays are central to surveillance programs, outbreak response, and disease control\u2014particularly for highly pathogenic avian influenza (HPAI) strains such as H5Nx. As Influenza A viruses continue to\u2026","rel":"","context":"In &quot;Animal Health and AgriGenomics&quot;","block_context":{"text":"Animal Health and AgriGenomics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/animal-health-and-agrigenomics\/"},"img":{"alt_text":"Chickens in a flock on a farm representing poultry populations monitored for avian influenza surveillance.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Untitled-3.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19159,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/scalable-molecular-testing-workflows\/","url_meta":{"origin":17970,"position":2},"title":"From Bottlenecks to Breakthroughs: Scaling Molecular Testing with OpenArray","author":"Ashleigh Barlow","date":"October 1, 2025","format":false,"excerpt":"At Livingston Med Lab in central Texas, the team has long prided itself on doing quality molecular medicine work including qPCR, array cards, and infectious disease panels, and always pushing to offer more to its community. But a roadblock emerged when they asked: how do we scale more efficiently without\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19748,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/andes-virus-rt-qpcr-detection-workflow\/","url_meta":{"origin":17970,"position":3},"title":"Responding to Hantavirus: Advancing Rapid Molecular Detection","author":"Behind The Bench Staff","date":"May 14, 2026","format":false,"excerpt":"Article Summary Laboratories responding to the emerging 2026 Andes hantavirus incident need rapid, scalable molecular workflows that can integrate into existing RT-qPCR infrastructure. This workflow is best suited for public health laboratories, surveillance programs, academic research labs, and high-throughput testing facilities seeking rapid research-use-only (RUO) molecular detection capabilities. By combining\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Illustration of hantavirus transmission showing rodent-derived viral particles entering the human respiratory system.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Hantavirus-3-1_Geoffrey-Cassell.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19888,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/streptococcus-pneumoniae-serotype-identification-qpcr-nested-pcr\/","url_meta":{"origin":17970,"position":4},"title":"qPCR, Nested PCR, and the Search for Bacterial Serotypes","author":"Ashleigh Barlow","date":"August 5, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Donna Paznar, former Head of Molecular Infection Diagnostics at the Medical University of Vienna, discusses her research on Streptococcus pneumoniae and its impact across the Austrian population. She explains why children can act as asymptomatic reservoirs, why tracking bacterial serotypes matters, and\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Donna Paznar discussing molecular methods for identifying Streptococcus pneumoniae serotypes.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19776,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/epigenetic-methylation-analysis-qpcr-dpcr\/","url_meta":{"origin":17970,"position":5},"title":"Epigenetics unlocked: How behavior shapes biology","author":"Ashleigh Barlow","date":"May 28, 2026","format":false,"excerpt":"Article Summary Epigenetics is helping researchers understand how environment, behavior, and molecular regulation intersect. Rather than changing the underlying DNA sequence, epigenetic changes influence how genes are expressed, including when they are turned on, turned off, or regulated in response to biological and environmental signals. In this episode of Absolute\u2026","rel":"","context":"In &quot;Epigenetics&quot;","block_context":{"text":"Epigenetics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/epigenetics\/"},"img":{"alt_text":"Portrait of Dr. Robert Philibert discussing epigenetics, DNA methylation, and behavioral biomarkers.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/07\/mastitis-testing.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=17970"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/17970\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/17975"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=17970"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=17970"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=17970"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=17970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}