{"id":18081,"date":"2023-09-19T08:00:37","date_gmt":"2023-09-19T08:00:37","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=18081"},"modified":"2025-08-18T14:13:04","modified_gmt":"2025-08-18T14:13:04","slug":"heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/","title":{"rendered":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected"},"content":{"rendered":"<p><span data-contrast=\"auto\">To ensure the drugs used in clinical environments behave as expected and do not produce unwanted side effects, it is important the quality of the product is verified prior to distribution. For manufactured heparin, it is vital that the activity of the heparin-antithrombin complex meets designated standards to ensure the quality of the final product. UV-Visible absorption spectrophotometer can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Heparin, a polysaccharide compound, is an anti-coagulant used to treat thromboembolisms and other conditions.\u00b9- \u00b3 The compound is often administered prior to kidney dialysis.\u2074 Heparin functions as it does due to a particular pentasaccharide region that consists of sulfated glucosamine residues not commonly found elsewhere in the compound. This pentasaccharide region will bind with antithrombin, a protein in the blood stream which functions as a naturally occurring mild blood thinner.\u2075 The resulting heparin-antithrombin complex inhibits serine proteases such as factor IIa and factor Xa at much greater rates than antithrombin alone does. These proteases, factor IIa and factor Xa, are enzymes which aid in coagulation, and their inhibition by the heparin-antithrombin complex (known as anti-factor IIa and anti-factor Xa activity), prevents blood coagulation.\u00b9, \u00b2 <\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">Avoiding Unwanted Side Effects<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;201341983&quot;:0,&quot;335559738&quot;:40,&quot;335559739&quot;:0,&quot;335559740&quot;:276}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\">For safe usage, the quality of pharmaceuticals must be properly vetted to help ensure they do not produce undesired side effects. For example, some batches of manufactured heparin have been found to be contaminated by the presence of oversulfated chondroitin sulfate.\u2074 The presence of this moiety in the produced drug has been linked to allergic reactions. Adverse effects like this highlight the need to thoroughly test the quality of drug products prior to distribution.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">For manufactured heparin, it is vital that the activity of the heparin-antithrombin complex meets designated standards to ensure the quality of the final product.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The <a href=\"https:\/\/www.usp.org\/\">US Pharmacopeia<\/a> (USP) has developed a quality test to ensure the activity of the manufactured heparin meets required specifications.\u2076 In this method, the activities of the produced heparin and of USP heparin standards for both factor IIa and factor Xa are determined using a colorimetric assay. This assay requires the use of a <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/uv-vis-spectrophotometry\/resources.html?icid=CAD_blog_LSM_2023Sept\">UV-Visible absorption spectrophotometer<\/a>.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The test compares the measured absorbance of a set of heparin sample solutions to a set of standard solutions. The ratio of the activity of the heparin samples versus the activity of the standards, for both anti-factor IIa and anti-factor Xa, is then compared to acceptance criteria outlined by USP.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">UV-Vis Spectrophotometer Principles<\/span><\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/uv-vis-spectrophotometry\/resources.html?icid=CAD_blog_LSM_2023Sept\"><span data-contrast=\"none\">UV-Visible spectroscopy<\/span><\/a><span data-contrast=\"auto\"> is a well-established analytical technique used in the pharmaceutical industry for testing in the research and quality control stages of drug development. UV-Visible spectroscopy measures the absorption or reflectance of light in the ultraviolet and \/or visible region of the spectrum.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">In the most basic terms, spectrophotometers enable photometric comparisons of relative light intensities across the ultraviolet and visible spectrums. Directing a controlled, constant intensity light source (halogen, deuterium, xenon) across the spectrum or at a specific wavelength through a sample easily can confirm known or calculate unknown characteristics of the sample. The incident light (I0) can be redirected backward as reflection, suffer an energy loss as absorption, and pass through transparent or translucent samples as transmission. (Read more about <\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/uv-vis-spectrophotometry\/resources.html?icid=CAD_blog_LSM_2023Sept\"><span data-contrast=\"none\">UV-Vis spectrophotometers.<\/span><\/a><span data-contrast=\"auto\">)<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">Experiment<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;201341983&quot;:0,&quot;335559738&quot;:40,&quot;335559739&quot;:0,&quot;335559740&quot;:276}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\">To see if UV-Vis technology is a suitable option to verify the quality of heparin, a <\/span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/840-341400?icid=CAD_blog_LSM_2023Sept\"><span data-contrast=\"auto\">UV-Vis Spectrophotometer<\/span><\/a><span data-contrast=\"auto\"> was used to measure the absorption of the prepared heparin standards and samples in the presence of a chromogenic substrate. This instrument meets USP requirements outlined in USP\u202f.\u2077 The sample preparation and measurements were carried out based on USP\u202fmonograph\u202f. Data analysis was performed using the built-in analysis functionalities in the instrument software. The procedure known as the anti-factor IIa assay was carried out based on the USP\u202f procedure.\u2076 <\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">In this case, the UV-Vis spectrophotometer was useful in confirming that the particular heparin samples analyzed in one experiment did not meet established USP standards.\u00a0 You can read the details about the experiment and why the sample did not fall in the acceptable range &#8212; including absorption measurements, collected and calculated results, concentration charts, slope ratios, and equations used &#8212; in the <\/span><span data-contrast=\"auto\">application note <\/span><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/anti-factor-xa-and-IIa-assays-for-unfractioned-heparin-activity-an53623-en.pdf\"><i><span data-contrast=\"none\">Anti-Factor Xa and IIa Assays for Unfractioned Heparin Activity<\/span><\/i><\/a><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">Additional Resources:<\/span><\/h2>\n<p><span data-contrast=\"auto\"><br \/>\nApplication Note: <\/span><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/anti-factor-xa-and-IIa-assays-for-unfractioned-heparin-activity-an53623-en.pdf\"><i><span data-contrast=\"none\">Anti-Factor Xa and IIa Assays for Unfractioned Heparin Activity<\/span><\/i><\/a><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<p><i><span data-contrast=\"auto\">References:<\/span><\/i><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n<ol>\n<li><span data-contrast=\"auto\"> Suzuki, T.; Ishii-Watabe, A.; Hashii, N.; Nakagawa, Y.; Takahashi, T.; Ebisawa, A.; Nishi, S.; Fujita, N.; Bando, A.; Sekimoto, Y.; Miyata, K.; Endo, T.; Otsu, T.; Sugimoto, S.; Kondou, T.; Fujita, Y.; Miyanaga, N.; Mashimo, M.; Shimada, N.; Yoden, H.; Shimamura, H.; Kurata, Y.; Koyama, S.; Kawasaki, N., The Establishment and Validation of Efficient Assays for Anti-IIa and Anti-Xa Activities of Heparin Sodium and Heparin Calcium, Biologicals, 2013, 41, 214 \u2013 423.<\/span><\/li>\n<li><span data-contrast=\"auto\"> Linhardt, R.J., Rice, K.C.; Merchant, Z.M.; Kim, Y.S.; Lohse, D.L, Structure and Activity of a Unique Heparin-derived Hexasaccharide, J. Biol. Chem., 1986, 261, 14448 \u2013 14454.<\/span><\/li>\n<li><span data-contrast=\"auto\"> Egan, G.; Ensom, M.H.H., Measuring Anti-Factor Xa Activity to Monitor LowMolecular-Weight Heparin in Obesity: A Critical Review, Can. J. Hosp. Pharm., 2015, 1, 33 \u2013 47.<\/span><\/li>\n<li><span data-contrast=\"auto\"> Guerrini, M.; Beccati, D.; Shriver, Z.; Naggi, A.; Viswanathan, K.; Bisio, A.; Capila, I.; Lansing, J.C.; Guglieri, S.; Fraser, B.; Al-Hakim, A.; Gunay, N. S.; Zhang, Z.; Robinson, L.; Buhse, L.; Nasr, M.; Woodcock, J.; Langer, R.; Venkataraman, G.; Linhardt, R.J.; Casu, B.; Torri, G.; Sasisekharan, R., Oversulfated Chondroitin Sulfate is a Contaminant in Heparin Associated with Adverse Clinical Events, Nat. Biotechnol., 2008, 26, 669 \u2013 675.<\/span><\/li>\n<li><span data-contrast=\"auto\"> Oscarsson, L.G.; Pejler, G.; Lindahl, U., Location of the Antithrombin-binding Sequence in the Heparin Chain, J. Biol. Chem., 1989, 264, 296 \u2013 304.<\/span><\/li>\n<li><span data-contrast=\"auto\"> USP. Anti-factor Xa and Anti-Factor IIa Assays for Unfractioned and Low Molecular Weight Heparins. In: USP\u2013NF. Rockville, MD: USP.<\/span><\/li>\n<li><span data-contrast=\"auto\"> USP. Ultraviolet-Visible Spectroscopy. In: USP\u2013NF. Rockville, MD: USP.<\/span><\/li>\n<\/ol>\n<p><span data-contrast=\"none\">For Research Use Only. Not for use in diagnostic procedures.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:200,&quot;335559740&quot;:276}\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>To ensure the drugs used in clinical environments behave as expected and do not produce unwanted side effects, it is important the quality of the product is verified prior to distribution. For manufactured heparin, it is vital that the activity of the heparin-antithrombin complex meets designated standards to ensure the quality of the final product.<\/p>\n","protected":false},"author":38,"featured_media":18083,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172,1087],"tags":[2361,2348,2364,2362,2363],"division":[],"class_list":{"0":"post-18081","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"category-pharmamfg","9":"tag-drug-development","10":"tag-drug-manufacturing","11":"tag-pharma-quality","12":"tag-quality-management","13":"tag-uv-vis-spectroscopy","14":"entry"},"_selected_authors":[773],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected - Behind the Bench<\/title>\n<meta name=\"description\" content=\"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected\" \/>\n<meta property=\"og:description\" content=\"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2023-09-19T08:00:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T14:13:04+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2119\" \/>\n\t<meta property=\"og:image:height\" content=\"1414\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\"},\"headline\":\"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected\",\"datePublished\":\"2023-09-19T08:00:37+00:00\",\"dateModified\":\"2025-08-18T14:13:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/\"},\"wordCount\":960,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/09\\\/iStock-867398442_vialssyringe.jpg\",\"keywords\":[\"Drug development\",\"drug manufacturing\",\"pharma quality\",\"Quality management\",\"UV-Vis spectroscopy\"],\"articleSection\":[\"General\",\"Pharma &amp; Biotech Manufacturing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/\",\"name\":\"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/09\\\/iStock-867398442_vialssyringe.jpg\",\"datePublished\":\"2023-09-19T08:00:37+00:00\",\"dateModified\":\"2025-08-18T14:13:04+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\"},\"description\":\"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/09\\\/iStock-867398442_vialssyringe.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2023\\\/09\\\/iStock-867398442_vialssyringe.jpg\",\"width\":2119,\"height\":1414},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\",\"name\":\"Marlene Gasdia-Cochrane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mgasdiacochrane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected - Behind the Bench","description":"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/","og_locale":"en_US","og_type":"article","og_title":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected","og_description":"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2023-09-19T08:00:37+00:00","article_modified_time":"2025-08-18T14:13:04+00:00","og_image":[{"width":2119,"height":1414,"url":"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/"},"author":{"name":"Marlene Gasdia-Cochrane","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8"},"headline":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected","datePublished":"2023-09-19T08:00:37+00:00","dateModified":"2025-08-18T14:13:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/"},"wordCount":960,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","keywords":["Drug development","drug manufacturing","pharma quality","Quality management","UV-Vis spectroscopy"],"articleSection":["General","Pharma &amp; Biotech Manufacturing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/","name":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","datePublished":"2023-09-19T08:00:37+00:00","dateModified":"2025-08-18T14:13:04+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8"},"description":"Learn how UV-Visible spectroscopy can be an effective tool in the analysis of heparin anti-factor IIa and Xa activity.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","width":2119,"height":1414},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/heparin-quality-should-be-verified-before-distribution-to-help-ensure-it-will-behave-as-expected\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Heparin Quality Should be Verified Before Distribution to Help Ensure It Will Behave as Expected"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8","name":"Marlene Gasdia-Cochrane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"},{"value":1087,"label":"Pharma &amp; Biotech Manufacturing"}],"post_tag":[{"value":2361,"label":"Drug development"},{"value":2348,"label":"drug manufacturing"},{"value":2364,"label":"pharma quality"},{"value":2362,"label":"Quality management"},{"value":2363,"label":"UV-Vis spectroscopy"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe-1024x683.jpg",760,507,true],"author_info":{"display_name":"Marlene Gasdia-Cochrane","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"},"comment_info":0,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":159,"filter":"raw","meta":[],"cat_ID":172,"category_count":159,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":1087,"name":"Pharma &amp; Biotech Manufacturing","slug":"pharmamfg","term_group":0,"term_taxonomy_id":1087,"taxonomy":"category","description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","parent":0,"count":60,"filter":"raw","meta":[],"cat_ID":1087,"category_count":60,"category_description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","cat_name":"Pharma &amp; Biotech Manufacturing","category_nicename":"pharmamfg","category_parent":0}],"tag_info":[{"term_id":2361,"name":"Drug development","slug":"drug-development","term_group":0,"term_taxonomy_id":2361,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":2348,"name":"drug manufacturing","slug":"drug-manufacturing","term_group":0,"term_taxonomy_id":2348,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":2364,"name":"pharma quality","slug":"pharma-quality","term_group":0,"term_taxonomy_id":2364,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":2362,"name":"Quality management","slug":"quality-management","term_group":0,"term_taxonomy_id":2362,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":2363,"name":"UV-Vis spectroscopy","slug":"uv-vis-spectroscopy","term_group":0,"term_taxonomy_id":2363,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19109,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/twin-screw-granulation-in-oral-solid-dosage-manufacturing-process-benefits-optimization\/","url_meta":{"origin":18081,"position":0},"title":"Twin-Screw Granulation in Oral Solid Dosage Manufacturing \u2013 Process, Benefits &amp; Optimization","author":"Marlene Gasdia-Cochrane","date":"September 2, 2025","format":false,"excerpt":"Oral solid dosage forms, such as tablets and capsules, are among the most common and preferred methods of drug delivery due to their convenience, stability, and patient compliance. The production of these pharmaceuticals requires precise control and optimization of several processes, from raw material preparation to final packaging. Understanding these\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Macro Shot of Pink Pills During Production and Packing Process on Modern Pharmaceutical Factory. Medical Drug Manufacturing.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/08\/iStock-1465073080_pillmfg.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19528,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/geometry-dependent-vs-parameter-driven-scale-up-in-pharmaceutical-manufacturing\/","url_meta":{"origin":18081,"position":1},"title":"Geometry-Dependent\u00a0vs\u00a0Parameter-Driven Scale Up\u00a0in Pharmaceutical Manufacturing\u00a0","author":"Marlene Gasdia-Cochrane","date":"March 31, 2026","format":false,"excerpt":"Overview\u00a0 Scale-up challenges in pharmaceutical manufacturing often stem from a fundamental distinction between geometry-dependent and parameter-driven systems. Processes that perform consistently at lab scale can shift unexpectedly at production scale. This is\u00a0often because the\u00a0governing physical logic was misunderstood. In geometry-dependent systems, equipment size directly alters heat transfer, mixing, dwell time,\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Macro Shot of Pink Pills During Production and Packing Process on Modern Pharmaceutical Factory. Medical Drug Manufacturing.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19376,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/why-most-modern-drug-candidates-fail-at-solubility\/","url_meta":{"origin":18081,"position":2},"title":"Why Most Modern Drug Candidates Fail at Solubility\u00a0","author":"Marlene Gasdia-Cochrane","date":"February 17, 2026","format":false,"excerpt":"Drug discovery capabilities continue to advance rapidly. Medicinal chemists are designing molecules with unprecedented potency and selectivity, enabling therapies that were not possible even a decade ago. Yet despite these scientific gains, many promising drug candidates still struggle to reach patients. One of the most common reasons is poor solubility.\u00a0\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Fizzing Tablet in Water","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-182713597.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19353,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/manufacturing-strategy-in-pharma-scale-up-vs-scale-out-for-continuous-processes\/","url_meta":{"origin":18081,"position":3},"title":"Scale-Up vs. Scale-Out Strategies for Continuous Pharma Manufacturing","author":"Marlene Gasdia-Cochrane","date":"February 3, 2026","format":false,"excerpt":"As pharmaceutical pipelines evolve, manufacturing strategies are being tested in new ways. Drug candidates are more complex, development timelines are tighter, and expectations for quality and consistency continue to rise. Against this backdrop, one question comes up repeatedly for formulation and manufacturing teams:\u00a0should we scale up, or should we scale\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Sorting pharmaceutical capsules by a sorting machine on a production line","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19168,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/understanding-dna-melting-analysis-using-uv-visible-spectroscopy\/","url_meta":{"origin":18081,"position":4},"title":"Understanding DNA Melting Analysis Using UV-Visible Spectroscopy","author":"Marlene Gasdia-Cochrane","date":"October 14, 2025","format":false,"excerpt":"DNA melting analysis is a vital molecular biology technique used to study the stability and properties of DNA by monitoring its transition from double-stranded to single-stranded form with increasing temperature. UV-visible spectroscopy measures changes in DNA absorbance during this process, providing insights into DNA stability, sequence composition, and molecular interactions.\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Close-up Of Dna Molecule On Blue Background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/iStock-2200215349.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19150,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/scanning-electron-microscopy-for-microneedle-patch-testing\/","url_meta":{"origin":18081,"position":5},"title":"Scanning Electron Microscopy for Microneedle Patch Testing","author":"Marlene Gasdia-Cochrane","date":"September 30, 2025","format":false,"excerpt":"Microneedle patches represent a significant advancement in drug delivery systems. These patches offer a painless and efficient method for administering medications through the skin. The application of Scanning Electron Microscopy (SEM) in testing microneedle patches has provided valuable insights into their structural integrity and performance. What are Microneedle Patches Microneedle\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"MicroNeedle","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2023\/09\/iStock-867398442_vialssyringe.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/18081","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/38"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=18081"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/18081\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/18083"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=18081"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=18081"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=18081"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=18081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}