{"id":19271,"date":"2025-12-03T01:18:20","date_gmt":"2025-12-03T01:18:20","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=19271"},"modified":"2025-12-03T06:30:27","modified_gmt":"2025-12-03T06:30:27","slug":"multiplex-qpcr-basics-guide","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","title":{"rendered":"Multiplex vs. Singleplex qPCR: What do I need to know?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Real-time PCR (qPCR) has transformed how scientists detect and quantify nucleic acid targets, offering analytical sensitivity, speed, and scalability. Many real-time PCR reactions measure a single target per well \u2014 a setup called singleplex qPCR.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, the effectiveness of real-time PCR can be increased by an approach called multiplex qPCR. By amplifying and detecting multiple independent targets within the same well, multiplex qPCR allows you to obtain more data from fewer reactions, efficiently use reagents, and improve reproducibility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you\u2019re analyzing gene expression or detecting pathogens, multiplexing helps streamline your workflow.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-from-singleplex-to-multiplex-how-it-works\">From singleplex to multiplex: How it works<a id=\"_msocom_1\"><\/a><\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">A typical real-time PCR assay includes two primers and, when using Applied Biosystems\u2122 TaqMan\u2122 chemistry, a fluorescently labeled probe. &nbsp;In singleplex experiments, one assay is amplified per well. &nbsp;In multiplex qPCR, two or more targets are amplified simultaneously, each identified by a probe labeled with its own dye.<br><br>Among available chemistries, Applied Biosystems\u2122 TaqMan\u2122 probe\u2013based assays are among the best suited for multiplexing because each probe provides both specificity and independent fluorescence detection. &nbsp;This dual capability allows researchers to amplify multiple assays in one reaction and detect each target independently.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-why-choose-multiplex-qpcr\">Why choose multiplex qPCR?<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">Multiplex qPCR can offer important advantages over singleplex workflows:<br><br>\u2022 Higher throughput \u2013 Detect more targets per well, increasing the number of samples that can be amplified in a plate.<br>\u2022 Lower reagent and sample use \u2013 Efficiently use reagents and limited biological samples.<br>\u2022 Improved precision and reliability \u2013 Internal controls within the same well normalize variability.<br>\u2022 Enhanced data confidence \u2013 Unlike singleplex experiments, all targets and the control are tied to each other in each well.<br><br>While duplexing (two targets per well) is often a practical first step, the power of multiplex qPCR can be further increased by combining three or more assays in a single reaction. Thermo Fisher Scientific&#8217;s advanced tools, services and products make high-order multiplexing (up to six targets) not only achievable but increasingly accessible.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-when-multiplexing-makes-the-most-sense\">When multiplexing makes the most sense<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">Multiplexing helps deliver the most significant benefit when you are:<br>\u2022 Amplifying large sample cohorts using a consistent set of assays.<br>\u2022 Needing more quality assurance in the data.<br>\u2022 Working with limited or precious sample material.<br><br>If your project requires a large number of assays (for example, more than 12), a real-time PCR array may be more efficient.<br><br>As the number of targets in the multiplex increases (3\u20136), careful planning becomes even more important.\u00a0 Thermo Fisher Technical Applications Scientists and Field Applications Scientists can provide guidance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-how-to-design-a-successful-multiplex-qpcr-assay\">How to design a successful multiplex qPCR assay<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">The recipe for developing an effective multiplex qPCR workflow includes assay considerations and testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-identify-compatible-assays\">1. <strong>Identify compatible assays<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Start by selecting the assays you wish to combine. The number of assays you can multiplex depends on your instrument\u2019s optical filters. For instance, if your real-time PCR instrument has six detection channels, you can theoretically multiplex up to six targets.<br><br>Use the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/life-science\/assay-support.html\" target=\"_blank\" rel=\"noreferrer noopener\">Multiplexing Support Request Tool<\/a> on the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays\/assay-design.html#assay-design\" target=\"_blank\" rel=\"noreferrer noopener\">qPCR Assay Design Hub<\/a> to check assay compatibility. Thermo Fisher\u2019s Multiplexing Support Team offers free <em>in silico<\/em> analysis to identify potential unwanted primer or probe interactions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-choose-the-right-reporter-dyes\">2. <strong>Choose the right reporter dyes<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Proper dye selection helps ensure clear spectral discrimination. &nbsp;Recommended dyes include: Applied Biosystems\u2122 FAM\u2122, VIC\u2122, ABY\u2122\/NED\u2122, JUN\u2122, Cy5\u2122, and Cy5.5\u2122. Most Applied Biosystems\u2122 reagents include the passive reference dye ROX\u2122, which provides many benefits \u2014 especially for multiplex reactions.&nbsp; Consider avoiding red reporter dyes, such as JUN, to allow the use of ROX.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ABY, NED, and TAMRA are all orange-emitting dyes.&nbsp; Avoid having multiple dyes of similar emissions in a multiplex. Using dyes, the instrument is already calibrated for, simplifies multiplexing.&nbsp; When using non-standard dyes, called custom dyes, custom dye calibrations will be needed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-primer-concentrations\">3. <strong>Primer concentrations<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For singleplex TaqMan probe-based assays, universal primer concentration (900 nM) is recommended.&nbsp; However, in a multiplex, universal primer concentration could allow a more abundant target\u2019s amplicon to reach a concentration that saturates <em>Taq<\/em> DNA polymerase, which could suppress amplification of lesser abundant targets.&nbsp; To prevent polymerase saturation in a multiplex, an assay can be formulated with a reduced primer concentration, called primer-limited.&nbsp; The researcher should choose which assays need to be primer-limited based on anticipated target abundances.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"777\" src=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Example-of-polymerase-saturation-1024x777.jpg\" alt=\"Diagram comparing singleplex and multiplex qPCR, showing multiple fluorescent dye channels detecting several targets in a single reaction.\" class=\"wp-image-19278\" style=\"width:486px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Example-of-polymerase-saturation-1024x777.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Example-of-polymerase-saturation-300x228.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Example-of-polymerase-saturation-768x583.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Example-of-polymerase-saturation.jpg 1053w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Example of polymerase saturation<\/strong><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If universal singleplex primer concentration (900nM) is used, the higher abundance gene continues to amplify until the polymerase is saturated, causing amplification to transition to linear phase. Amplification of the lower abundance gene must also transition to linear phase when <em>Taq<\/em> DNA polymerase is saturated. In this saturation scenario, the Ct value of the lesser abundant gene is inaccurate or even absent; the multiplex failed.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Higher-abundance-gene-1024x512.jpg\" alt=\"Graph illustrating how polymerase saturation affects multiplex qPCR amplification curves and how primer limitation improves detection of low-abundance targets\" class=\"wp-image-19279\" style=\"width:486px\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Higher-abundance-gene-1024x512.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Higher-abundance-gene-300x150.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Higher-abundance-gene-768x384.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Higher-abundance-gene.jpg 1425w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Polymerase saturation is prevented by a reduction in primer concentration, called \u201cprimer limitation.\u201d A primer limited assay transitions from exponential to linear phase due to primer exhaustion rather than saturation of the polymerase, allowing exponential amplification to be detected for the lower abundance gene.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4448484?SID=srch-srp-4448484\" target=\"_blank\" rel=\"noreferrer noopener\">VIC-labeled, primer-limited (PL)<\/a> formats can be selected online for Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays\/taqman-gene-expression.html\" target=\"_blank\" rel=\"noreferrer noopener\">TaqMan\u2122 \u00a0Gene Expression Assays<\/a>\u00a0or Applied Biosystems\u2122 Custom TaqMan\u2122 \u00a0Gene Expression Assays.\u00a0 <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays\/taqman-custom-plating-manufacturing\/taqman-custom-assay-oligo.html\" target=\"_blank\" rel=\"noreferrer noopener\">Specialty oligos<\/a> can also synthesize assays with different reporter dyes and primer-limited format.<br><a id=\"_msocom_1\"><\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-performance-testing-before-scale-up\">4. <strong>Performance testing before scale-up<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before using a multiplex for its intended application, its performance should be tested.&nbsp; The more rigorous method of performance testing is by mixed standard curves.&nbsp; One target is serially diluted across a range likely to be encountered in samples. &nbsp;To these serial dilutions are added a consistent amount of a second target.&nbsp; The mixed standard curve is amplified in real-time PCR.&nbsp; Ideally, both targets will maintain linearity in the standard curve plot across the entire range tested.&nbsp; If the multiplex will be triplex or higher, multiple pairs of targets will need to be tested in this way.&nbsp; Note that Invitrogen\u2122 GeneArt\u2122, a part of Thermo Fisher, can synthesize DNA controls needed to create mixed standard curves.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A less rigorous way to test the performance of a multiplex is to amplify a representative collection of samples in singleplex and multiplex, and compare the results.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-synthesize-multiplex-assay-into-one-tube-optional\">5. <strong>Synthesize multiplex assay into one tube (optional)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If the performance of the multiplex has been verified as being acceptable, specialty oligos can help deliver the assays in a single tube format, which simplifies preparing the reactions and helps ensure consistent ratios among all the primers and probes.<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For Research Use Only. Not for use in diagnostic procedures<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-need-expert-help-contact-us\">Need expert help? Contact us<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">Ready to streamline your workflow with multiplex qPCR?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde Call 800-955-6288, option 2. When prompted, say \u201ctechnical support,\u201d then specify \u201creal-time PCR.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermo Fisher\u2019s Technical Applications Scientists and Field Applications Scientists are ready to help you design, test, and optimize your multiplex qPCR assays. Summary Multiplex qPCR helps you get more results from every reaction by enabling simultaneous detection of multiple targets within a single well. With smart dye and primer concentration selections, you can achieve multiplexing success: efficiently using reagents, time, and sample material. Leverage Thermo Fisher Scientific\u2019s tools, resources, and experienced professional guidance to bring your multiplex qPCR experiments to life.<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore: <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/taqman-multiplex-qpcr-solution.html\" target=\"_blank\" rel=\"noreferrer noopener\">Multiplexing resources<\/a> | <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/life-science\/assay-support.html\" target=\"_blank\" rel=\"noreferrer noopener\">Multiplexing Support Request Tool<\/a> | <a href=\"https:\/\/www.thermofisher.com\/order\/genome-database\/?pearUXVerSuffix=pearUX2&amp;elcanoForm=true#!\/\" target=\"_blank\" rel=\"noreferrer noopener\">Predesigned TaqMan\u2122 Assays<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;\u00a9 2025 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. TaqMan is a registered trademark of Roche Molecular Systems, Inc., used under permission and license.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a id=\"_msocom_1\"><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Real-time PCR (qPCR) has transformed how scientists detect and quantify nucleic acid targets, offering analytical sensitivity, speed, and scalability. Many real-time PCR reactions measure a single target per well \u2014 a setup called singleplex qPCR. However, the effectiveness of real-time PCR can be increased by an approach called multiplex qPCR. By amplifying and detecting multiple<\/p>\n","protected":false},"author":1793,"featured_media":19272,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172,108,2259],"tags":[120,20,46,27],"division":[],"class_list":["post-19271","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","category-lab-tips-and-tricks","category-molecular-diagnostics","tag-multiplex-sequencing","tag-qpcr","tag-real-time-pcr","tag-taqman-assay","entry"],"_selected_authors":[1100],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Multiplex qPCR Basics: How It Works and When to Use It<\/title>\n<meta name=\"description\" content=\"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Multiplex vs. Singleplex qPCR: What do I need to know?\" \/>\n<meta property=\"og:description\" content=\"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-03T01:18:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-03T06:30:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ashleigh Barlow\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ashleigh Barlow\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/\"},\"author\":{\"name\":\"Ashleigh Barlow\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9cd6fa1f2eca52a1cab4a12601fc43ee\"},\"headline\":\"Multiplex vs. Singleplex qPCR: What do I need to know?\",\"datePublished\":\"2025-12-03T01:18:20+00:00\",\"dateModified\":\"2025-12-03T06:30:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/\"},\"wordCount\":1222,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2025\\\/12\\\/Web-header-900-x-600-custom-web-page-size-feature-pods.png\",\"keywords\":[\"Multiplex sequencing\",\"qPCR\",\"Real Time PCR\",\"Taqman Assay\"],\"articleSection\":[\"General\",\"Lab Tips and Tricks\",\"Molecular Diagnostics\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/\",\"name\":\"Multiplex qPCR Basics: How It Works and When to Use It\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2025\\\/12\\\/Web-header-900-x-600-custom-web-page-size-feature-pods.png\",\"datePublished\":\"2025-12-03T01:18:20+00:00\",\"dateModified\":\"2025-12-03T06:30:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9cd6fa1f2eca52a1cab4a12601fc43ee\"},\"description\":\"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2025\\\/12\\\/Web-header-900-x-600-custom-web-page-size-feature-pods.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2025\\\/12\\\/Web-header-900-x-600-custom-web-page-size-feature-pods.png\",\"width\":900,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/multiplex-qpcr-basics-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Multiplex vs. Singleplex qPCR: What do I need to know?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9cd6fa1f2eca52a1cab4a12601fc43ee\",\"name\":\"Ashleigh Barlow\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g\",\"caption\":\"Ashleigh Barlow\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/ashleighbarlow\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Multiplex qPCR Basics: How It Works and When to Use It","description":"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","og_locale":"en_US","og_type":"article","og_title":"Multiplex vs. Singleplex qPCR: What do I need to know?","og_description":"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2025-12-03T01:18:20+00:00","article_modified_time":"2025-12-03T06:30:27+00:00","og_image":[{"width":900,"height":600,"url":"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","type":"image\/png"}],"author":"Ashleigh Barlow","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Ashleigh Barlow","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/"},"author":{"name":"Ashleigh Barlow","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9cd6fa1f2eca52a1cab4a12601fc43ee"},"headline":"Multiplex vs. Singleplex qPCR: What do I need to know?","datePublished":"2025-12-03T01:18:20+00:00","dateModified":"2025-12-03T06:30:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/"},"wordCount":1222,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","keywords":["Multiplex sequencing","qPCR","Real Time PCR","Taqman Assay"],"articleSection":["General","Lab Tips and Tricks","Molecular Diagnostics"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","name":"Multiplex qPCR Basics: How It Works and When to Use It","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","datePublished":"2025-12-03T01:18:20+00:00","dateModified":"2025-12-03T06:30:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9cd6fa1f2eca52a1cab4a12601fc43ee"},"description":"Learn how multiplex qPCR works, its advantages over singleplex assays, and key tips for designing successful multi-target real-time PCR workflows","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","width":900,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Multiplex vs. Singleplex qPCR: What do I need to know?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9cd6fa1f2eca52a1cab4a12601fc43ee","name":"Ashleigh Barlow","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ffa9b05d0f35cf4c6041578d6c5a047634604e604efa2286b297cae04e97512a?s=96&d=mm&r=g","caption":"Ashleigh Barlow"},"url":"https:\/\/admin.acceleratingscience.com\/author\/ashleighbarlow\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"},{"value":108,"label":"Lab Tips and Tricks"},{"value":2259,"label":"Molecular Diagnostics"}],"post_tag":[{"value":120,"label":"Multiplex sequencing"},{"value":20,"label":"qPCR"},{"value":46,"label":"Real Time PCR"},{"value":27,"label":"Taqman Assay"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png",760,507,false],"author_info":{"display_name":"Ashleigh Barlow","author_link":"https:\/\/admin.acceleratingscience.com\/author\/ashleighbarlow\/"},"comment_info":9,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":108,"category_count":103,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0},{"term_id":2259,"name":"Molecular Diagnostics","slug":"molecular-diagnostics","term_group":0,"term_taxonomy_id":2259,"taxonomy":"category","description":"","parent":0,"count":19,"filter":"raw","meta":[],"cat_ID":2259,"category_count":19,"category_description":"","cat_name":"Molecular Diagnostics","category_nicename":"molecular-diagnostics","category_parent":0}],"tag_info":[{"term_id":120,"name":"Multiplex sequencing","slug":"multiplex-sequencing","term_group":0,"term_taxonomy_id":120,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":20,"name":"qPCR","slug":"qpcr","term_group":0,"term_taxonomy_id":20,"taxonomy":"post_tag","description":"","parent":0,"count":37,"filter":"raw","meta":[]},{"term_id":46,"name":"Real Time PCR","slug":"real-time-pcr","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":55,"filter":"raw","meta":[]},{"term_id":27,"name":"Taqman Assay","slug":"taqman-assay","term_group":0,"term_taxonomy_id":27,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19606,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-optimization-6-plex\/","url_meta":{"origin":19271,"position":0},"title":"Optimizing multiplex qPCR: How to amplify up to 6 targets without compromising analytical sensitivity","author":"Behind The Bench Staff","date":"April 1, 2026","format":false,"excerpt":"What happens when a multiplex qPCR assay begins to lose performance as additional targets are introduced? An assay that performs reproducibly in singleplex can exhibit Ct shift, reduced sensitivity, or compressed dynamic range when scaled to 5- or 6-plex. As plex level increases, competition among primers, probes, reporter dyes, and\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Graph comparing Ct values between singleplex and multiplex qPCR reactions showing \u0394Ct shift as targets increase.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19966,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-assay-optimization-qpcr\/","url_meta":{"origin":19271,"position":1},"title":"Building Better Multiplex Panels: Identifying Assay Interactions Early","author":"Ashleigh Barlow","date":"September 8, 2026","format":false,"excerpt":"Multiplex qPCR has transformed molecular research by enabling scientists to detect multiple targets in a single reaction. The benefits are clear: reduced sample consumption, lower costs, faster workflows, and more data from every experiment. However, designing successful multiplex assays isn't always straightforward. Traditionally, identifying problematic assay combinations required extensive wet-lab\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"For Research Use Only. Not for use in diagnostic procedures. \u00a9 2026 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19685,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-primer-optimization\/","url_meta":{"origin":19271,"position":2},"title":"Multiplex qPCR primer optimization: How to balance amplification across targets","author":"Ashleigh Barlow","date":"May 1, 2026","format":false,"excerpt":"What happens when one target amplifies more efficiently than another in a multiplex qPCR reaction? In many experiments, targets are not present at equal abundance. Some amplify earlier, generate stronger signals, and begin to dominate the reaction. Others may appear delayed, or not at all. These effects are not always\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"DNA strands with multicolored signals representing simultaneous detection of multiple targets in multiplex qPCR.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Blog_qPCR_Reagent_multiplex_qPCR_primerlimitations-1-Multiplex-qPCR_hero.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Blog_qPCR_Reagent_multiplex_qPCR_primerlimitations-1-Multiplex-qPCR_hero.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Blog_qPCR_Reagent_multiplex_qPCR_primerlimitations-1-Multiplex-qPCR_hero.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Blog_qPCR_Reagent_multiplex_qPCR_primerlimitations-1-Multiplex-qPCR_hero.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Blog_qPCR_Reagent_multiplex_qPCR_primerlimitations-1-Multiplex-qPCR_hero.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19922,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/qpcr-master-mix-comparison\/","url_meta":{"origin":19271,"position":3},"title":"Think your supermix is good enough? Prove it.","author":"Ashleigh Barlow","date":"August 21, 2026","format":false,"excerpt":"The chemistry of your qPCR supermix can influence analytical sensitivity, specificity, precision, and overall assay performance. Even when you keep the same instrument, assays, and samples, different master mixes can perform differently. That's why we challenge you to put your supermix to the test. Compare it side by side with\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Applied Biosystems probe-based and SYBR Green qPCR master mixes for real-time PCR workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":19640,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/direct-from-lysate-snp-genotyping-in-research-applications\/","url_meta":{"origin":19271,"position":4},"title":"Direct-from-Lysate SNP Genotyping in Research Applications","author":"Ashleigh Barlow","date":"April 6, 2026","format":false,"excerpt":"Direct-from-lysate workflow enabled by DNA Extract All Reagents compared to traditional DNA purification for SNP genotyping applications. Can You Perform SNP Genotyping Without DNA Purification? The short answer: In many research workflows, direct-from-lysate SNP genotyping can be performed without traditional DNA purification\u2014when appropriate chemistries and verification procedures are used. Direct-from-lysate\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Comparison of traditional DNA purification workflow and direct-from-lysate workflow using DNA Extract All Reagents for SNP genotyping prior to qPCR.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19911,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-mirna-profiling-precision-oncology\/","url_meta":{"origin":19271,"position":5},"title":"A scalable multiplex miRNA profiling workflow for precision oncology research","author":"Ashleigh Barlow","date":"August 18, 2026","format":false,"excerpt":"The promise of precision oncology rests on our ability to reliably monitor tumor biology in real time. Circulating microRNAs (miRNAs) offer that opportunity, serving as potentially stable, non-invasive biomarkers linked to disease progression and therapeutic response; however, their adoption in routine practice remains constrained by technical hurdles. (1,2) Because cancer\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Scientist pipetting a laboratory sample during molecular biomarker research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/19271","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/1793"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=19271"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/19271\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/19272"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=19271"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=19271"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=19271"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=19271"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}