{"id":6996,"date":"2015-03-20T11:15:44","date_gmt":"2015-03-20T11:15:44","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=6996"},"modified":"2020-09-26T00:08:35","modified_gmt":"2020-09-26T00:08:35","slug":"sanger-sequencing-by-ce-1-foundations","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/","title":{"rendered":"Sanger Sequencing by CE 1: Foundations"},"content":{"rendered":"<p>Part 1: History and Significance of the accepted Gold Standard in DNA Sequencing<\/p>\n<p>This is Part One of a six-part series on Sanger sequencing and Capillary Electrophoresis, starting with the history and significance of the accepted gold standard in DNA sequencing. CE sequencing applications will follow.<\/p>\n<p>In 1951,\u00a0 Fred Sanger first determined the sequence of two proteins (the bovine insulin A and B forms), showing that they were distinct molecules, and for this he was awarded a Nobel Prize in Chemistry in 1958. In 1965,\u00a0 he lost the race to be the first to sequence a tRNA molecule. In 1977,\u00a0 he introduced the <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC431765\/\" target=\"_blank\" rel=\"noopener noreferrer\">\u201cdi-deoxy\u201d chain-termination method<\/a>, which earned him a second Nobel Prize in Chemistry in 1980 (which he shared with <a href=\"http:\/\/www.nobelprize.org\/nobel_prizes\/chemistry\/laureates\/1980\/index.html\" target=\"_blank\" rel=\"noopener noreferrer\">Paul Berg and Walter Gilbert,<\/a> of the Maxam-Gilbert chemical-based method of sequencing ). \u2018Sanger method\u2019 became the standard method for sequencing for its ease-of-use; in particular it did not require the use of hazardous chemicals as it was a biochemical method mimicking natural DNA synthesis.<\/p>\n<p>By utilizing a mixture of natural nucleotides (deoxy-nucleotide triphosphates or dNTPs for short) with modified ones (dideoxy-nucleotide triphosphates or ddNTPs), in the normal course of DNA polymerization, a given molecule being extended will randomly add a dideoxynucleotide. Without a 3\u2019-hydroxy group to continue polymerization (thus the name \u201cdi-deoxynucleotide\u201d), that molecule will stop growing, and after the reaction is finished, there is a mixture of products of differing sizes.<\/p>\n<p>The invention of PCR in 1985 was rapidly included into the Sanger sequencing process (so-called \u2018cycle-sequencing\u2019), and the availability of <sup>35<\/sup>S-labeled dNTPs made the process relatively safer than the high gamma radiation-emitting <sup>32<\/sup>P-end-labeled primers.<\/p>\n<p>A graphical video of the <a href=\"http:\/\/media.invitrogen.com.edgesuite.net\/ab\/applications-technologies\/pharma-biotherapeutics\/DNA_sequencing.swf?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">sequencing process<\/a> is available to further illustrate this.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-6997 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png\" alt=\"ce1\" width=\"594\" height=\"388\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png 1148w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1-300x196.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1-768x502.png 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1-1024x669.png 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1-400x261.png 400w\" sizes=\"auto, (max-width: 594px) 100vw, 594px\" \/><\/p>\n<p>When this technique was first introduced in the late 1970\u2019s, radioactive end-labeled\u00a0 primers were used and each reaction separated into four distinct reaction tubes, one for each didoxynucleotide. Thus, the tube labeled \u2018A\u2019 would have a mix of all four dNTP\u2019s (the normal chemical nucleotides for DNA chain elongation) and ddATP. Each reaction tube would then be separated individually on large acrylamide slab electrophoresis gels (these gels were large, on the order of about 30cm x 50cm; and after drying the gel and autoradiography to X-ray film the DNA ladder could be read.<\/p>\n<p>Of course this process was manual, with a fluorescent light-box to read the autoradiogram, a ruler, and (hopefully) an assistant to enter the four letters into the computer one base at a time. G. G. A. A. T. T. C. C. A\u2026 It wasn\u2019t unusual to have to go back a second time to double-check the accuracy, and from setup of the sequencing reaction to pouring the gel and polymerizing it to running the gel to drying the gel and then to reading the gel would take about a day and a half.<\/p>\n<p><strong>A major shift in sequencing technology<\/strong><\/p>\n<p>Fast-forward over twenty years, and the radionucleotides have been replaced with dye-termination nucleotides. (Thermo Fisher Scientific has currently <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/fragment-analysis\/fragment-analysis-applications.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">four different terminator chemistries<\/a>, including the popular BigDye\u00ae Terminators v3.1.)\u00a0 In addition, instead of x-ray film, heavy x-ray film cassettes (with the requisite intensifying screen necessitating placing the film plus cassette in a -80C freezer overnight) and darkroom film manipulation (along with maintaining the film developer, yet another unwelcome laboratory chore), an automated detection system uses a scanning laser and a photomultiplier tube with advanced optics to read the fluorescent dye, for direct automated entry of DNA base sequence data.<\/p>\n<p>While this major shift away from radioactivity and x-ray film to fluorescence and optical detection occurred with the introduction of the Applied Biosystems\u00ae 370A DNA Sequencer in 1986, the next major advance occurred when the ABI\u00ae Prism 310 genetic analyzer was introduced in 1995. The ABI\u00ae Prism 310 tackled the other rather unpleasant aspect of DNA sequencing at that time: pouring gels. These electrophoresis gel glass plates need fastidious handling, as a speck of dust can easily form an air bubble as the glass sheets between which the acrylamide is polymerized is typically 0.4mm wide. In addition, fresh acrylamide solutions are needed for optimum performance, which necessitated handling dry acrylamide, a suspected carcinogen.<\/p>\n<p><strong>Sequencing technology mirrors genomics<\/strong><\/p>\n<p>Only a few years after the introduction of the ABI\u00ae Prism 310, the 96-capillary AB 3700 became the workhorse of the Human Genome Project. This was a 100-fold improvement in only 5 years, a remarkable testament to the internal development teams to develop the biochemistry, polymer chemistry, and mechanical\/optical engineering. In an interview (still <a href=\"http:\/\/www3.appliedbiosystems.com\/cms\/groups\/mcb_marketing\/documents\/generaldocuments\/cms_040165.pdf?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">available as a PDF here<\/a>)\u00a0 Dr. Elaine Mardis (then co-director of the Washington University Genome Sequencing Center) said of the AB\u00ae3700: \u201cI don\u2019t think the human genome, wherever you look at it being done, could have been done without these instruments.\u201d\u00a0 The importance of this sequencing technology to the <em>E. coli<\/em> genome, the <em>Saccharomyces cerevisiae<\/em> genome, the <em>Caenorhabditis elegans<\/em> genome, the <em>Drosophila melanogaster<\/em> genome, and the <em>Mus musculus<\/em> genome leading directly to the <em>Homo Sapiens<\/em> genome cannot be overstated, as the accelerating pace of science rose in tandem with the accelerating pace of technical development of the sequencing technology.<\/p>\n<p>After these decades of technical improvement, Sanger sequencing by capillary electrophoresis has a justified claim of being the gold standard for sequence quality. Incremental improvements from protein engineering of the DNA polymerase used for sequencing (modified nucleotides with inorganic fluorescent dyes are relatively large, requiring a fair amount of engineering of the nucleotide \u2018pocket\u2019), chemical improvements of the acrylamide and other components of the POP polymer separation matrix, optical improvements to sense subtle changes in fluorescence coupled with newer dye-chemistry, and finally software improvements in base-calling and error-modeling helped enable Sanger sequencing by capillary electrophoresis to provide highly accurate results in very high accuracy.<\/p>\n<p>Our current system, the <a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/4440462?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 3500 Series Genetic Analyzer<\/a>, includes a wide array of technology that enables this system to be simple to use. Everything from a solid-state long-life laser, radio-frequency identification tags (RFID) to track consumables usage and lot number information, pre-packaged polymer pouches, and data collection software are all designed for ease-of-use.<\/p>\n<p><strong>A word on accuracy<\/strong><\/p>\n<p>With so much improvement over time, and so many years which the system has been developed, the error model for Sanger sequencing is without equal. Quantified by a <a href=\"http:\/\/en.wikipedia.org\/wiki\/Phred_quality_score\" target=\"_blank\" rel=\"noopener noreferrer\">program called Phred<\/a> and defined as Q = &#8211; 10 log<sub>10<\/sub> P where Q is the quality score, and P is the error of probability. For example with a 10% error, the Phred quality score is 10, and the accuracy is therefore 90%. At a Phred quality score of 20, the error is 1%, and the accuracy is 99%; at 30, the error is 0.1%, and the accuracy is 99.9%.<\/p>\n<p>The overall accuracy of Sanger sequencing is accepted to be on the order of 99.95%, or an overall error of 0.05%. With read-lengths of 800 to 1000 base-pairs, these two aspects of Sanger sequencing (accuracy and read-length) make it the gold standard for sequencing.<\/p>\n<p>If you want to learn more, here\u2019s a great reference resource called <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/fragment-analysis-guide-registration-form.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">\u201cDNA Sequencing by Capillary Electrophoresis \u2013 Applied Biosystems Chemistry Guide\u201d<\/a>.\u00a0 It is very comprehensive, and as a PDF it doesn\u2019t take a lot of room on your desk.<\/p>\n<p>References: <a href=\"http:\/\/tools.lifetechnologies.com\/content\/sfs\/posters\/ABI6247_SOLiD_Timeline_v4_ONLINE.pdf\">A history of innovation in genetic science<\/a>. Applied Biosystems (PDF)<\/p>\n<p>Check out the whole Series:<\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger Sequencing by CE 1: Foundations<\/a><\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-using-ce-2-fragment-analysis\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger Sequencing using CE 2: Fragment Analysis<\/a><\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/using-ce-3-designing-a-27-plex-pcr-for-fragment-analysis\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Fragment Analysis using CE 3: Designing a 27-plex PCR<\/a><\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-4-bioinformatics\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger Sequencing by CE 4: Bioinformatics<\/a><\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-5-sanger-sequencing-applications\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger Sequencing by CE 5: Sanger Sequencing Applications<\/a><\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-6-resources\/?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger Sequencing by CE 6: Resources<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Part 1: History and Significance of the accepted Gold Standard in DNA Sequencing This is Part One of a six-part series on Sanger sequencing and Capillary Electrophoresis, starting with the history and significance of the accepted gold standard in DNA sequencing. CE sequencing applications will follow. In 1951,\u00a0 Fred Sanger first determined the sequence of<\/p>\n","protected":false},"author":120,"featured_media":6997,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[108],"tags":[17,36,99,25,74],"division":[],"class_list":{"0":"post-6996","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-lab-tips-and-tricks","8":"tag-applied-biosystems","9":"tag-capillary-electrophoresis","10":"tag-fragment-analysis","11":"tag-sanger-sequencing","12":"tag-sequencing","13":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Sanger Sequencing by CE 1: Foundations - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sanger Sequencing by CE 1: Foundations\" \/>\n<meta property=\"og:description\" content=\"Part 1: History and Significance of the accepted Gold Standard in DNA Sequencing This is Part One of a six-part series on Sanger sequencing and Capillary Electrophoresis, starting with the history and significance of the accepted gold standard in DNA sequencing. CE sequencing applications will follow. In 1951,\u00a0 Fred Sanger first determined the sequence of\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-03-20T11:15:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-26T00:08:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1148\" \/>\n\t<meta property=\"og:image:height\" content=\"750\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Sanger Sequencing by CE 1: Foundations\",\"datePublished\":\"2015-03-20T11:15:44+00:00\",\"dateModified\":\"2020-09-26T00:08:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/\"},\"wordCount\":1218,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/12\\\/ce1.png\",\"keywords\":[\"Applied Biosystems\",\"Capillary Electrophoresis\",\"Fragment Analysis\",\"Sanger Sequencing\",\"sequencing\"],\"articleSection\":[\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/\",\"name\":\"Sanger Sequencing by CE 1: Foundations - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/12\\\/ce1.png\",\"datePublished\":\"2015-03-20T11:15:44+00:00\",\"dateModified\":\"2020-09-26T00:08:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/12\\\/ce1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/12\\\/ce1.png\",\"width\":1148,\"height\":750},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/sanger-sequencing-by-ce-1-foundations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sanger Sequencing by CE 1: Foundations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Sanger Sequencing by CE 1: Foundations - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/","og_locale":"en_US","og_type":"article","og_title":"Sanger Sequencing by CE 1: Foundations","og_description":"Part 1: History and Significance of the accepted Gold Standard in DNA Sequencing This is Part One of a six-part series on Sanger sequencing and Capillary Electrophoresis, starting with the history and significance of the accepted gold standard in DNA sequencing. CE sequencing applications will follow. In 1951,\u00a0 Fred Sanger first determined the sequence of","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-03-20T11:15:44+00:00","article_modified_time":"2020-09-26T00:08:35+00:00","og_image":[{"width":1148,"height":750,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","type":"image\/png"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Sanger Sequencing by CE 1: Foundations","datePublished":"2015-03-20T11:15:44+00:00","dateModified":"2020-09-26T00:08:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/"},"wordCount":1218,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","keywords":["Applied Biosystems","Capillary Electrophoresis","Fragment Analysis","Sanger Sequencing","sequencing"],"articleSection":["Lab Tips and Tricks"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/","name":"Sanger Sequencing by CE 1: Foundations - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","datePublished":"2015-03-20T11:15:44+00:00","dateModified":"2020-09-26T00:08:35+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","width":1148,"height":750},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-by-ce-1-foundations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Sanger Sequencing by CE 1: Foundations"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":36,"label":"Capillary Electrophoresis"},{"value":99,"label":"Fragment Analysis"},{"value":25,"label":"Sanger Sequencing"},{"value":74,"label":"sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1-1024x669.png",760,497,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":1,"category_info":[{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":100,"filter":"raw","meta":[],"cat_ID":108,"category_count":100,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":36,"name":"Capillary Electrophoresis","slug":"capillary-electrophoresis","term_group":0,"term_taxonomy_id":36,"taxonomy":"post_tag","description":"","parent":0,"count":50,"filter":"raw","meta":[]},{"term_id":99,"name":"Fragment Analysis","slug":"fragment-analysis","term_group":0,"term_taxonomy_id":99,"taxonomy":"post_tag","description":"","parent":0,"count":37,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]},{"term_id":74,"name":"sequencing","slug":"sequencing","term_group":0,"term_taxonomy_id":74,"taxonomy":"post_tag","description":"","parent":0,"count":158,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":6996,"position":0},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20004,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/a-guide-to-nucleic-acid-quality-control-dna-and-rna-purity\/","url_meta":{"origin":6996,"position":1},"title":"A Guide to Nucleic Acid Quality Control: DNA and RNA Purity","author":"Marlene Gasdia-Cochrane","date":"September 22, 2026","format":false,"excerpt":"Article Summary Nucleic acid quality control helps researchers evaluate DNA and RNA concentration and purity before downstream applications such as PCR, qPCR, and next-generation sequencing (NGS). A standardized workflow combining reliable extraction, concentration and purity assessment, application-appropriate quantification, and consistent laboratory practices can help identify sample issues early, improve reproducibility,\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Close-up shot of a dna sequence on a screen, a digital representation of genetic code, used for analysis.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19883,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/building-a-better-sample-qc-workflow-from-extraction-to-sequencing\/","url_meta":{"origin":6996,"position":2},"title":"Building a Better Sample QC Workflow: From Extraction to Sequencing","author":"Marlene Gasdia-Cochrane","date":"August 25, 2026","format":false,"excerpt":"Article Summary Successful genomics experiments don't begin with sequencing\u2014they begin with sample quality. Every downstream application, from PCR to next-generation sequencing (NGS), depends on starting with nucleic acids that are accurately quantified and free from contaminants that could compromise results. Establishing a consistent quality control workflow helps laboratories improve reproducibility\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"A pipette drops a liquid into a petri dish with a dna sequence background, science concept. It suggests medical or genetic research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19888,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/streptococcus-pneumoniae-serotype-identification-qpcr-nested-pcr\/","url_meta":{"origin":6996,"position":3},"title":"qPCR, Nested PCR, and the Search for Bacterial Serotypes","author":"Ashleigh Barlow","date":"August 5, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Donna Paznar, former Head of Molecular Infection Diagnostics at the Medical University of Vienna, discusses her research on Streptococcus pneumoniae and its impact across the Austrian population. She explains why children can act as asymptomatic reservoirs, why tracking bacterial serotypes matters, and\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Donna Paznar discussing molecular methods for identifying Streptococcus pneumoniae serotypes.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19345,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/precision-oncology-diagnostics\/","url_meta":{"origin":6996,"position":4},"title":"The Expanding Role of Molecular Diagnostics in Precision Oncology","author":"Behind The Bench Staff","date":"January 13, 2026","format":false,"excerpt":"https:\/\/www.youtube.com\/watch?v=F6FfHIizJBY For Dr. Harald Bartsch, a clinical pathologist in southern Bavaria, molecular diagnostic tools have become an indispensable part of his arsenal. \u201cI believe molecular diagnostics play a crucial role in modern oncology, and I see this as the direction everything is headed,\u201d says Dr. Bartsch. While immunohistochemistry remains central\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Clinical Pathologist in a Molecular Diagnostics Laboratory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":6996,"position":5},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/12\/ce1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/6996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=6996"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/6996\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/6997"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=6996"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=6996"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=6996"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=6996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}