{"id":8088,"date":"2016-03-24T13:13:52","date_gmt":"2016-03-24T13:13:52","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=8088"},"modified":"2020-09-26T00:17:19","modified_gmt":"2020-09-26T00:17:19","slug":"how-to-generate-high-quality-sanger-sequencing-data","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/","title":{"rendered":"How to Generate High Quality Sanger Sequencing Data"},"content":{"rendered":"<p>Considered as the gold standard, <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger sequencing<\/a> technology has been proven through decades of results. You might be familiar with the simple workflow or already have an established protocol in your lab.\u00a0 However, with the new applications developed for Sanger sequencing such as <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-dna-sequencing\/sanger-sequencing-data-analysis\/minor-variant-finder-software.html?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">minor variant detection<\/a>, the data quality that you are getting out of your protocol just might not be up to par.<\/p>\n<p>To help researchers generate high-quality data for minor variant detection, we put together a few user bulletins to provide some best practices and troubleshooting tips to help make your life in the lab easier.\u00a0 These protocols have been extensively tested to ensure high quality, reproducible results. Check it out!\u00a0 You might uncover a new possibility for your <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Capillary Electrophoresis instrument<\/a>\u00a0and perhaps finally resolve that data issue that you\u2019ve been trying to live with for years.<\/p>\n<h3><a style=\"line-height: 1.5\" href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014628_BigDyeTermin_Cycle_Seq_hiqual_data_UB.pdf?cid=techcomm94?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Generating high\u2011quality data using the BigDye \u2122 Terminator v3.1 Cycle Sequencing Kit<\/strong><\/a><\/h3>\n<div class=\"mceTemp\"><\/div>\n<p><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014628_BigDyeTermin_Cycle_Seq_hiqual_data_UB.pdf?cid=techcomm94?socid=social_btb_abseq\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8091\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech1-232x300.jpg\" alt=\"tech1\" width=\"107\" height=\"139\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech1-232x300.jpg 232w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech1.jpg 265w\" sizes=\"auto, (max-width: 107px) 100vw, 107px\" \/><\/a><\/p>\n<p>A protocol for generating high\u2011quality data for use in minor variant detection using:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4337458?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">BigDye\u2122 Terminator v3.1 Cycle Sequencing Kit<\/a><\/li>\n<li>Applied Biosystems\u2122 Genetic Analyzers with POP\u20116\u2122 or POP\u20117\u2122 polymer<\/li>\n<\/ul>\n<h3><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014436_BigDyeDirect_Cycle_Seq_hiqual_data_UB.pdf?cid=techcomm93?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Generating high\u2011quality data using the BigDye \u2122 Direct Cycle Sequencing Kit<\/strong><\/a><\/h3>\n<p><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014436_BigDyeDirect_Cycle_Seq_hiqual_data_UB.pdf?cid=techcomm93?socid=social_btb_abseq\" target=\"_blank\" rel=\"attachment wp-att-8090 noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8090 \" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech2-233x300.jpg\" alt=\"tech2\" width=\"107\" height=\"138\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech2-233x300.jpg 233w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech2.jpg 264w\" sizes=\"auto, (max-width: 107px) 100vw, 107px\" \/><\/a><\/p>\n<p>Sequencing with the<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-kits-reagents\/bigdye-direct-sanger-sequencing-kit.html?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\"> BigDye Direct Cycle Sequencing Kit<\/a> takes fewer steps and less hands-on time.\u00a0 By combing PCR clean-up and cycle sequencing into a single step, the BigDye Direct workflow reduces the traditional Sanger sequencing workflow time by up to 40%. This protocol is also optimized for sequencing short amplicons, since BigDye Direct\u2019s novel sequencing primer and chemistry enable high data quality from base 1 after the sequencing primer.<\/p>\n<h3><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014435_Trbleshoot_Sanger_seq_data_UB.pdf?cid=techcomm92?socid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Troubleshooting Sanger sequencing data<br \/>\n<\/strong><\/a><\/h3>\n<div class=\"mceTemp\"><\/div>\n<p><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/manuals\/MAN0014435_Trbleshoot_Sanger_seq_data_UB.pdf?cid=techcomm92?socid=social_btb_abseq\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8089\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech3-231x300.jpg\" alt=\"tech3\" width=\"109\" height=\"142\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech3-231x300.jpg 231w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/tech3.jpg 239w\" sizes=\"auto, (max-width: 109px) 100vw, 109px\" \/><\/a><\/p>\n<p>Do you experience signal saturation, low signal intensity, dye blobs\u2026etc. from your data? This document provides guidance with troubleshooting tips for improving sequencing data quality.<\/p>\n<p>Did these help you solve your problems and achieve higher quality data? Let us know what you think about these tips and tricks in the comments section below.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Considered as the gold standard, Sanger sequencing technology has been proven through decades of results. You might be familiar with the simple workflow or already have an established protocol in your lab.\u00a0 However, with the new applications developed for Sanger sequencing such as minor variant detection, the data quality that you are getting out of<\/p>\n","protected":false},"author":120,"featured_media":8403,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[108],"tags":[17,36,99,153,25,74],"division":[],"class_list":{"0":"post-8088","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-lab-tips-and-tricks","8":"tag-applied-biosystems","9":"tag-capillary-electrophoresis","10":"tag-fragment-analysis","11":"tag-genomic-variants","12":"tag-sanger-sequencing","13":"tag-sequencing","14":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Generate High Quality Sanger Sequencing Data - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Generate High Quality Sanger Sequencing Data\" \/>\n<meta property=\"og:description\" content=\"Considered as the gold standard, Sanger sequencing technology has been proven through decades of results. You might be familiar with the simple workflow or already have an established protocol in your lab.\u00a0 However, with the new applications developed for Sanger sequencing such as minor variant detection, the data quality that you are getting out of\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-24T13:13:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-26T00:17:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"How to Generate High Quality Sanger Sequencing Data\",\"datePublished\":\"2016-03-24T13:13:52+00:00\",\"dateModified\":\"2020-09-26T00:17:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/\"},\"wordCount\":327,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/03\\\/Digital-illustration-of-a-DNA-strand.jpg\",\"keywords\":[\"Applied Biosystems\",\"Capillary Electrophoresis\",\"Fragment Analysis\",\"Genomic Variants\",\"Sanger Sequencing\",\"sequencing\"],\"articleSection\":[\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/\",\"name\":\"How to Generate High Quality Sanger Sequencing Data - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/03\\\/Digital-illustration-of-a-DNA-strand.jpg\",\"datePublished\":\"2016-03-24T13:13:52+00:00\",\"dateModified\":\"2020-09-26T00:17:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/03\\\/Digital-illustration-of-a-DNA-strand.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/03\\\/Digital-illustration-of-a-DNA-strand.jpg\",\"width\":1000,\"height\":667,\"caption\":\"Digital illustration of a DNA strand\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-generate-high-quality-sanger-sequencing-data\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Generate High Quality Sanger Sequencing Data\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Generate High Quality Sanger Sequencing Data - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/","og_locale":"en_US","og_type":"article","og_title":"How to Generate High Quality Sanger Sequencing Data","og_description":"Considered as the gold standard, Sanger sequencing technology has been proven through decades of results. You might be familiar with the simple workflow or already have an established protocol in your lab.\u00a0 However, with the new applications developed for Sanger sequencing such as minor variant detection, the data quality that you are getting out of","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-03-24T13:13:52+00:00","article_modified_time":"2020-09-26T00:17:19+00:00","og_image":[{"width":1000,"height":667,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"How to Generate High Quality Sanger Sequencing Data","datePublished":"2016-03-24T13:13:52+00:00","dateModified":"2020-09-26T00:17:19+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/"},"wordCount":327,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","keywords":["Applied Biosystems","Capillary Electrophoresis","Fragment Analysis","Genomic Variants","Sanger Sequencing","sequencing"],"articleSection":["Lab Tips and Tricks"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/","name":"How to Generate High Quality Sanger Sequencing Data - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","datePublished":"2016-03-24T13:13:52+00:00","dateModified":"2020-09-26T00:17:19+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","width":1000,"height":667,"caption":"Digital illustration of a DNA strand"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-generate-high-quality-sanger-sequencing-data\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"How to Generate High Quality Sanger Sequencing Data"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":36,"label":"Capillary Electrophoresis"},{"value":99,"label":"Fragment Analysis"},{"value":153,"label":"Genomic Variants"},{"value":25,"label":"Sanger Sequencing"},{"value":74,"label":"sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg",760,507,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":101,"filter":"raw","meta":[],"cat_ID":108,"category_count":101,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":36,"name":"Capillary Electrophoresis","slug":"capillary-electrophoresis","term_group":0,"term_taxonomy_id":36,"taxonomy":"post_tag","description":"","parent":0,"count":50,"filter":"raw","meta":[]},{"term_id":99,"name":"Fragment Analysis","slug":"fragment-analysis","term_group":0,"term_taxonomy_id":99,"taxonomy":"post_tag","description":"","parent":0,"count":37,"filter":"raw","meta":[]},{"term_id":153,"name":"Genomic Variants","slug":"genomic-variants","term_group":0,"term_taxonomy_id":153,"taxonomy":"post_tag","description":"","parent":0,"count":69,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]},{"term_id":74,"name":"sequencing","slug":"sequencing","term_group":0,"term_taxonomy_id":74,"taxonomy":"post_tag","description":"","parent":0,"count":158,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":8088,"position":0},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19345,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/precision-oncology-diagnostics\/","url_meta":{"origin":8088,"position":1},"title":"The Expanding Role of Molecular Diagnostics in Precision Oncology","author":"Behind The Bench Staff","date":"January 13, 2026","format":false,"excerpt":"https:\/\/www.youtube.com\/watch?v=F6FfHIizJBY For Dr. Harald Bartsch, a clinical pathologist in southern Bavaria, molecular diagnostic tools have become an indispensable part of his arsenal. \u201cI believe molecular diagnostics play a crucial role in modern oncology, and I see this as the direction everything is headed,\u201d says Dr. Bartsch. While immunohistochemistry remains central\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Clinical Pathologist in a Molecular Diagnostics Laboratory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19883,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/building-a-better-sample-qc-workflow-from-extraction-to-sequencing\/","url_meta":{"origin":8088,"position":2},"title":"Building a Better Sample QC Workflow: From Extraction to Sequencing","author":"Marlene Gasdia-Cochrane","date":"August 25, 2026","format":false,"excerpt":"Article Summary Successful genomics experiments don't begin with sequencing\u2014they begin with sample quality. Every downstream application, from PCR to next-generation sequencing (NGS), depends on starting with nucleic acids that are accurately quantified and free from contaminants that could compromise results. Establishing a consistent quality control workflow helps laboratories improve reproducibility\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"A pipette drops a liquid into a petri dish with a dna sequence background, science concept. It suggests medical or genetic research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19223,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/innovations-in-qpcr-technology\/","url_meta":{"origin":8088,"position":3},"title":"Innovations in qPCR Technology: What Researchers Need to Know","author":"Ashleigh Barlow","date":"October 29, 2025","format":false,"excerpt":"https:\/\/youtu.be\/z9Kb1xAnNcg?si=TVUIc8rUxZUOhCqA Real-time PCR, also known as quantitative polymerase chain reaction (qPCR) technology, has been a cornerstone of molecular biology research for decades. With continuous advancements, qPCR remains a critical tool for researchers worldwide. Damien Luk, Senior Director of Product Management at Thermo Fisher Scientific, shared his insights on the future\u2026","rel":"","context":"In &quot;Developmental Biology&quot;","block_context":{"text":"Developmental Biology","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/developmental-biology\/"},"img":{"alt_text":"A lineup of Thermo Fisher Scientific QuantStudio real-time PCR systems, including QuantStudio 3, 5, 6 Pro, 7 Pro, and 12K Flex instruments, displayed against a blue gradient background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/qPCR-Blog-Cover-Image.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20004,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/a-guide-to-nucleic-acid-quality-control-dna-and-rna-purity\/","url_meta":{"origin":8088,"position":4},"title":"A Guide to Nucleic Acid Quality Control: DNA and RNA Purity","author":"Marlene Gasdia-Cochrane","date":"September 22, 2026","format":false,"excerpt":"Article Summary Nucleic acid quality control helps researchers evaluate DNA and RNA concentration and purity before downstream applications such as PCR, qPCR, and next-generation sequencing (NGS). A standardized workflow combining reliable extraction, concentration and purity assessment, application-appropriate quantification, and consistent laboratory practices can help identify sample issues early, improve reproducibility,\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Close-up shot of a dna sequence on a screen, a digital representation of genetic code, used for analysis.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":8088,"position":5},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/03\/Digital-illustration-of-a-DNA-strand.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8088","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=8088"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8088\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/8403"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=8088"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=8088"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=8088"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=8088"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}