{"id":8763,"date":"2016-06-15T17:26:50","date_gmt":"2016-06-15T17:26:50","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=8763"},"modified":"2025-03-12T19:08:45","modified_gmt":"2025-03-12T19:08:45","slug":"crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/","title":{"rendered":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8759 alignright\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex.jpg\" alt=\"CRISPR cas9 DNA protein complex\" width=\"242\" height=\"227\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex.jpg 8000w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex-300x282.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex-768x721.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex-1024x962.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex-1250x1174.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/CRISPR-cas9-DNA-protein-complex-400x376.jpg 400w\" sizes=\"auto, (max-width: 242px) 100vw, 242px\" \/>Genome editing is not a new concept to the scientific community and has been around for decades. However, directing precise sequence changes at desired sites has remained a difficult and tedious challenge for researchers. Limited successes have been achieved with oligonucleotides, small molecules, or self-splicing introns, but the development of site-directed zinc finger nucleases (ZFNs) and TAL effector nucleases (TALENs) has facilitated sequence-specific manipulations. Nevertheless, difficulties of protein design, synthesis, and testing have slowed adoption of these engineered nucleases for routine use in genome editing experiments. The most recent gene editing technology, the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/genome-editing\/geneart-crispr\/crispr-cas9-based-genome-editing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">CRISPR-Cas9 system<\/a>, largely overcomes these difficulties, making it an attractive method for genome editing. It is critical that we adopt a workflow and use technology that can make genome editing efficient by accurately identifying on- and off-target mutations, producing a gene-edited organism that may have fewer or no off-targeted gene side effects<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. Today, with the aid of gene editing tools, researchers can quickly generate model organisms that can be used to study human diseases, test efficacy of various drugs, and even create genetically modified organisms during times of an epidemic, as has been done for the <em>Aedes<\/em> <em>aegypti<\/em> mosquito, a vector for the Zika virus<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0122353\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>3<\/sup><\/a>.<\/p>\n<h3><strong>Understanding the CRISPR-Cas9 gene editing system<\/strong><\/h3>\n<p>Clustered regularly interspaced short palindromic repeats (CRISPRs) belong to a class of repeated DNA sequences that work together with CRISPR-associated (Cas) genes to protect bacteria and archaea from invading foreign nucleotides, such as those from phages and plasmid DNA<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. Upon injection of phage-DNA into the bacteria, the phage-DNA is cut into small pieces and incorporated into the CRISPR locus<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. This locus, now containing information about the foreign phage-DNA is transcribed, this CRISPR-RNA (crRNA) along with a second non-coding RNA, trans-activating CRISPR RNA (tracrRNA), then forms a ribonucleoprotein complex with the Cas9 endonuclease and cuts the foreign DNA from this specific phage<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. So, a bacteria carrying information about a specific phage-DNA can have immunity towards attack from that phage<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\"><sup>2<\/sup><\/a>. In this way, bacteria and archaea have evolved an adaptive immune response against invading DNA and can protect themselves in the future when attacked by the same phage<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\"><sup>2<\/sup><\/a>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8764 alignleft\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg\" alt=\"cas9.\" width=\"493\" height=\"246\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg 691w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2-300x150.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2-400x200.jpg 400w\" sizes=\"auto, (max-width: 493px) 100vw, 493px\" \/>This CRISPR-Cas9 system that provides adaptive immunity against foreign elements in bacteria and archaea, has been modified today to be able to edit genes in various cell types (mammalian, plant, insect, fungi, etc)<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. Researchers combined the crRNA and\u00a0tracrRNA and generated a single guide RNA (sgRNA), which recruits the Cas9 nuclease to specific genomic locations with guidance from the sgRNA. sgRNA then pairs with the complimentary genomic sequences via Watson-Crick pairing and the Cas9 nuclease induces double strand breaks (DSB)<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. The DSB can be corrected by an error-prone mechanism called, non-homologous end joining (NHEJ), which causes insertions or deletions<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>. If a synthetic template is present, the DSB can also be corrected by homology-directed repair (HDR), allowing the introduction of desired base-changes into the genome<a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>1<\/sup><\/a><sup>, <\/sup><a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>2<\/sup><\/a>.<\/p>\n<p>The CRISPR-Cas9 system is one of many and there are probably many such tools that have yet to be discovered. Using Sanger sequencing, performed on the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 3130xl genetic analyzer<\/a>, Ivanov et al were able to discover CRISPRs in a newly discovered <em>Bordetella<\/em> species<a href=\"http:\/\/bmcgenomics.biomedcentral.com\/articles\/10.1186\/s12864-015-2028-9\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>4<\/sup><\/a>. The Cas9 endonuclease gene in the <em>Bordetella<\/em> species is 990bp, which is smaller than that of <em>Streptococcus pyogenes<\/em> Cas9 (SpyCas9) gene<a href=\"http:\/\/bmcgenomics.biomedcentral.com\/articles\/10.1186\/s12864-015-2028-9\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>4<\/sup><\/a>. The CRISPR-SpyCas9 system is the most widely studied and used, the newly discovered smaller <em>Bordetella<\/em> Cas9, which is equally functional and active as the SpyCas9 might be an attractive alternative for the widely used CRISPR-Cas9 system<a href=\"http:\/\/bmcgenomics.biomedcentral.com\/articles\/10.1186\/s12864-015-2028-9\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>4<\/sup><\/a>.<\/p>\n<h3><strong>Improving the CRISPR-Cas9 workflow<\/strong><\/h3>\n<p>We\u2019ve provided an <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/crispr-talen-genome-editing-sanger-sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">end-to-end integrated workflow<\/a> with all the tools necessary for genome editing and downstream analysis. The <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/genome-editing\/geneart-crispr\/geneart-crispr-search-and-design-tool.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 GeneArt\u2122 design tool<\/a> facilitates the design and ordering of target specific gRNAs for CRISPR-mediated genome editing or TALs for TALEN mediated genome editing. <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-culture\/transfection.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 transfection reagents<\/a> offer several options for delivery of genome editing tools into eukaryotic cells. In addition, <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cloning\/topo\/topo-resources\/the-technology-behind-topo-cloning.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Invitrogen\u2122 TOPO\u2122 TA cloning vectors<\/a> and <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cloning\/competent-cells-for-transformation.html?cid=topo-compcells-0713?socid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">competent cells<\/a> facilitate the sequence analysis of primary transformants. <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/brands\/gibco.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Gibco\u2122 media<\/a> is available for growing the primary transformants and secondary cultures following clonal expansion. Finally, <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 sequencing instruments<\/a>,\u00a0reagents and software (<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-dna-sequencing\/sanger-sequencing-data-analysis\/minor-variant-finder-software.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 Minor Variant Finder Software<\/a>\u00a0or <a href=\"https:\/\/tide.nki.nl\/\" target=\"_blank\" rel=\"noopener noreferrer\">TIDE software<\/a>) enable the determination of specific genomic editing events.<\/p>\n<p>For accurate and efficient gene editing, it is critical that we confirm the sequences of the guide RNAs and synthetic templates used for DSB repair, to assure efficient targeting. Sanger sequencing can not only help in testing the sequence of the sgRNA, but also in screening cells post-gene editing, to check for on- and off target mutations and to make sure there are no unwanted insertions, deletions or mutations that may possibly lead to frameshift mutations.<\/p>\n<div id=\"attachment_8765\" style=\"width: 1034px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/crispr-talen-genome-editing-sanger-sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8765\" class=\"wp-image-8765 size-large\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-1024x486.jpg\" width=\"1024\" height=\"486\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-1024x486.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-300x142.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-768x365.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-1250x594.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631-400x190.jpg 400w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/crispr-1-e1465927825631.jpg 1430w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><p id=\"caption-attachment-8765\" class=\"wp-caption-text\">Overall workflow for CRISPR genome editing. Click for more information.<\/p><\/div>\n<h3><strong>Applications of CRISPR-Cas9 gene editing system<\/strong><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-320\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-1024x683.jpg\" alt=\"Zika mosquito\" width=\"193\" height=\"128\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-1024x683.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-96x65.jpg 96w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-1250x833.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/04\/Zika-mosquito-400x267.jpg 400w\" sizes=\"auto, (max-width: 193px) 100vw, 193px\" \/>As the Zika epidemic continues, researchers have been trying to figure out a way to reduce the spread and growth of the <em>Aedes aegypti<\/em> mosquito, which is a vector for Zika and various other viruses<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0122353\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>3<\/sup><\/a>. Dong et al showed for the first time that the CRISPR-Cas9 system could be used to disrupt a gene in the <em>Aedes Aegypti<\/em> mosquito<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0122353\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>3<\/sup><\/a>. They used the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/3730XL?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 3730xl genetic analyzer<\/a> to sequence the DNA of regions targeted by the CRISPR-Cas9 system, validating their results<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0122353\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>3<\/sup><\/a>. Such research opens up the application of a specific workflow to various organisms, showing that genome editing can be easily used to insert or delete genes in an organism of interest.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8761 alignleft\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-1024x683.jpg\" alt=\"Piglet\" width=\"207\" height=\"138\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-1024x683.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-96x65.jpg 96w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-1250x833.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Piglet-400x267.jpg 400w\" sizes=\"auto, (max-width: 207px) 100vw, 207px\" \/>Research has shown that when the <em>MSTN<\/em> gene is knocked out it increases skeletal muscle in mice. Rao et al were interested in generating <em>Myostatin<\/em> (<em>MSTN<\/em>)-knockout (KO) pigs using genome editing technology<a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>5<\/sup><\/a>. Using TALEN genome editing technology, they generated <em>MSTN<\/em>-KO somatic porcine cells<a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>5<\/sup><\/a>. The team used Sanger sequencing or <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Capillary Electrophoresis (CE)<\/a>, performed on the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 3130 genetic analyzer<\/a>, to determine mutations, small insertions or deletions and off-target mutations<a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>5<\/sup><\/a>. Cells carrying the correct KO were then used for somatic-cell nuclear transfer (SCNT) to generate <em>MSTN<\/em>-KO piglets<a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>5<\/sup><\/a>. Interestingly, these <em>MSTN<\/em>-KO piglets were higher in body weight and displayed increased muscle mass, compared to wildtype<a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>5<\/sup><\/a>. Such studies can compliment breeding efforts to help increase pork production.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-8758\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-1024x1024.jpg\" alt=\"Chick\" width=\"182\" height=\"182\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-1024x1024.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-300x300.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-768x768.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-80x80.jpg 80w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-1250x1250.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-400x400.jpg 400w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Chick-200x200.jpg 200w\" sizes=\"auto, (max-width: 182px) 100vw, 182px\" \/>Genome editing in chickens can be difficult, due to accessibility of the zygote, compared to other organisms<a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>6<\/sup><\/a>. Oishi et al perform genome editing in chicken using the CRISPR-Cas9 system<a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>6<\/sup><\/a>. Using the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/genome-editing\/geneart-crispr\/crispr-cas9-based-genome-editing.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">CRISPR-Cas9 system<\/a>, the team targeted two egg white genes <em>ovalbumin<\/em> (<em>OVA<\/em>) and <em>ovomucoid<\/em> (<em>OVM<\/em>) in cultured chicken primordial germ cells (PGCs) <a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>6<\/sup><\/a>. They used Sanger sequencing to analyze off-target mutations and mutated <em>OVM<\/em> and <em>OVA<\/em> genes following genome editing in the targeted PGCs<a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>6<\/sup><\/a>. The mutant-PGCs were then transplanted into chicken embryos and the team was able to successfully generate <em>OVM<\/em> mutant chickens<a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>6<\/sup><\/a>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8760 alignleft\" src=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-1024x768.jpg\" alt=\"Lab rat\" width=\"201\" height=\"150\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-1024x768.jpg 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-300x225.jpg 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-768x576.jpg 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-1250x938.jpg 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Lab-rat-400x300.jpg 400w\" sizes=\"auto, (max-width: 201px) 100vw, 201px\" \/>Creating knockout or knockin models of animals can be very difficult even with access to a simple and powerful tool like the CRISPR-Cas9 systems. Kaneko et al have attempted to make this process simpler<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0142755\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>7<\/sup><\/a>. Using a method\u00a0called, technique for animal knockout system by electroporation (TAKE), they were able to introduce the CRISPR-Cas9 components into intact mice and rat embryos<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0142755\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>7<\/sup><\/a>. With the help of <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Sanger sequencing<\/a> they were able confirm the targeted gene in the offspring<a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0142755\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>7<\/sup><\/a>. Such research could potentially be used to help produce genetically modified animal models that may help us study human diseases in the future.<\/p>\n<h3><strong>Fine tuning technology and screening for a faster workflow<\/strong><\/h3>\n<p>As genome-editing research increases in popularity, it is important to identify fast and cost-effective screening techniques and efficient editing protocols. Liang et al, describe methods for rapid synthesis of the sgRNA and for delivery of the Cas9 protein\/gRNA ribonucleoprotein complexes into various mammalian cells either through electroporation or liposome-mediated transfection<a href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S016816561500200X\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>8<\/sup><\/a>. Along with several <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cloning\/gene-synthesis.html?icid=fr-geneart-main?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">GeneART\u2122 products<\/a>, the team used the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4440462?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied biosystems\u2122 3500 genetic analyzer<\/a> to detect error rates in the synthetic gRNA templates, off-target mutations and on-target indels<a href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S016816561500200X\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>8<\/sup><\/a>. They highlight an efficient two-locus and three-locus multigene targeting technique<a href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S016816561500200X\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>8<\/sup><\/a>. Together, the team was able to present a streamlined workflow that enables gRNA design to analysis of edited cells in ~4 days even in cells that are difficult to transfect<a href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S016816561500200X\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>8<\/sup><\/a>.<\/p>\n<p>When it comes to genome editing, not all transfected cells are edited and hence have to be screened. Screening can be a highly tedious and time-consuming process. Agostino et al identify a rapid, low-cost screening method using the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-instruments\/viia-7-real-time-pcr-system.html?cid=social_btb_genequant\" target=\"_blank\" rel=\"noopener noreferrer\">Viia\u21227 real-time PCR system<\/a><a href=\"http:\/\/link.springer.com\/article\/10.1007%2Fs12033-015-9905-y\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>9<\/sup><\/a>. The team optimizes melting parameters to be able to distinguish between wildtype and mutant melting curves and present an approach for massive preliminary screening<a href=\"http:\/\/link.springer.com\/article\/10.1007%2Fs12033-015-9905-y\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>9<\/sup><\/a>. After screening and identifying desired gene-edited cells\/embryos, they use the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/3730S?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">Applied Biosystems\u2122 3730 genetic analyzer<\/a> to test the indels and mutations in these cells\/embryos to confirm accurate editing<a href=\"http:\/\/link.springer.com\/article\/10.1007%2Fs12033-015-9905-y\" target=\"_blank\" rel=\"noopener noreferrer\"><sup>9<\/sup><\/a>.<\/p>\n<p>Such prior screening can help reduce the number of animal embryos used for research and reduce the number of unnecessary embryos used for downstream sequencing. Such improvements to current techniques has the power to help researchers produce desired gene-edited organisms or cells, in a fast, efficient, and cost-effective manner. <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/genome-editing.html?icid=fr-genomediting-main?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">Genome editing<\/a> is a powerful tool that can change how fast we do science. Our complete end-to-end workflow provides guidance on tools, techniques, applications, and technology that can help make this process simple, fast, cost-effective and most importantly, efficient.<\/p>\n<p>For more information:<br \/>\nLearn\u00a0about\u00a0Genome Editing with Sanger Sequencing\u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing\/applications\/crispr-talen-genome-editing-sanger-sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">here<\/a>.<br \/>\nDownload the Genome Editing workflow <a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/sanger-crispr-workflow-app-note.pdf?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">here<br \/>\n<\/a>Learn more about our Sequencing instruments <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"noopener noreferrer\">here<br \/>\n<\/a>Learn more about CRISPR reagents and products <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/genome-editing\/everything-you-need-for-crispr-success.html?cid=social_btb\" target=\"_blank\" rel=\"noopener noreferrer\">here<\/a><\/p>\n<p>For Research Use Only. Not for use in diagnostic procedures.<\/p>\n<hr \/>\n<p>References:<\/p>\n<p>1] Marraffini LA: <a href=\"http:\/\/www.nature.com\/nature\/journal\/v526\/n7571\/full\/nature15386.html\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>CRISPR-Cas immunity in prokaryotes<\/strong><\/a>. <em>Nature <\/em>2015, <strong>526<\/strong>(7571):55-61<\/p>\n<p>2] Savic N, Schwank G: <a href=\"http:\/\/www.translationalres.com\/article\/S1931-5244(15)00332-1\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Advances in therapeutic CRISPR\/Cas9 genome editing<\/strong><\/a>. <em>Transl Res <\/em>2016, <strong>168<\/strong>:15-21.<\/p>\n<p>3] Dong S, Lin J, Held NL, Clem RJ, Passarelli AL, Franz AW: <a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0122353\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Heritable CRISPR\/Cas9-mediated genome editing in the yellow fever mosquito, Aedes aegypti<\/strong><\/a>. <em>PLoS One <\/em>2015, <strong>10<\/strong>(3):e0122353<\/p>\n<p>4] Ivanov YV, Shariat N, Register KB, Linz B, Rivera I, Hu K, Dudley EG, Harvill ET: <a href=\"http:\/\/bmcgenomics.biomedcentral.com\/articles\/10.1186\/s12864-015-2028-9\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>A newly discovered Bordetella species carries a transcriptionally active CRISPR-Cas with a small Cas9 endonuclease<\/strong><\/a>. <em>BMC Genomics <\/em>2015, <strong>16<\/strong>(1):863.<\/p>\n<p>5] Rao S, Fujimura T, Matsunari H, Sakuma T, Nakano K, Watanabe M, Asano Y, Kitagawa E, Yamamoto T, Nagashima H: <a href=\"http:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrd.22591\/abstract\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Efficient modification of the myostatin gene in porcine somatic cells and generation of knockout piglets<\/strong><\/a>. <em>Mol Reprod Dev <\/em>2016, <strong>83<\/strong>(1):61-70.<\/p>\n<p>6] Oishi I, Yoshii K, Miyahara D, Kagami H, Tagami T: <a href=\"http:\/\/www.nature.com\/articles\/srep23980\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Targeted mutagenesis in chicken using CRISPR\/Cas9 system<\/strong><\/a>. <em>Sci Rep <\/em>2016, <strong>6<\/strong>:23980<\/p>\n<p>7] Kaneko T, Mashimo T: <a href=\"http:\/\/journals.plos.org\/plosone\/article?id=10.1371\/journal.pone.0142755\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Simple Genome Editing of Rodent Intact Embryos by Electroporation<\/strong><\/a>. <em>PLoS One <\/em>2015, <strong>10<\/strong>(11):e0142755.<\/p>\n<p>8] Liang X, Potter J, Kumar S, Zou Y, Quintanilla R, Sridharan M, Carte J, Chen W, Roark N, Ranganathan S<em> et al<\/em>: <a href=\"http:\/\/www.sciencedirect.com\/science\/article\/pii\/S016816561500200X\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>Rapid and highly efficient mammalian cell engineering via Cas9 protein transfection<\/strong><\/a>. <em>J Biotechnol <\/em>2015, <strong>208<\/strong>:44-53.<\/p>\n<p>9] D&#8217;Agostino Y, Locascio A, Ristoratore F, Sordino P, Spagnuolo A, Borra M, D&#8217;Aniello S: <a href=\"http:\/\/link.springer.com\/article\/10.1007%2Fs12033-015-9905-y\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>A Rapid and Cheap Methodology for CRISPR\/Cas9 Zebrafish Mutant Screening<\/strong><\/a>. <em>Mol Biotechnol <\/em>2016, <strong>58<\/strong>(1):73-78<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Genome editing is not a new concept to the scientific community and has been around for decades. However, directing precise sequence changes at desired sites has remained a difficult and tedious challenge for researchers. Limited successes have been achieved with oligonucleotides, small molecules, or self-splicing introns, but the development of site-directed zinc finger nucleases (ZFNs)<\/p>\n","protected":false},"author":120,"featured_media":8764,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[83,183,2452,67,101],"tags":[17,126,127,196,197,144,43,422,46,25],"division":[],"class_list":["post-8763","post","type-post","status-publish","format-standard","has-post-thumbnail","category-animal-health-and-agrigenomics","category-developmental-biology","category-gene-editing","category-infectious-diseases","category-product-news","tag-applied-biosystems","tag-crispr-cas9","tag-gene-editing","tag-geneart","tag-gibco","tag-invitrogen","tag-pcr","tag-pcr-workflow","tag-real-time-pcr","tag-sanger-sequencing","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground\" \/>\n<meta property=\"og:description\" content=\"Genome editing is not a new concept to the scientific community and has been around for decades. However, directing precise sequence changes at desired sites has remained a difficult and tedious challenge for researchers. Limited successes have been achieved with oligonucleotides, small molecules, or self-splicing introns, but the development of site-directed zinc finger nucleases (ZFNs)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-15T17:26:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-12T19:08:45+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"691\" \/>\n\t<meta property=\"og:image:height\" content=\"346\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"headline\":\"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground\",\"datePublished\":\"2016-06-15T17:26:50+00:00\",\"dateModified\":\"2025-03-12T19:08:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/\"},\"wordCount\":1800,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/cas9-2.jpg\",\"keywords\":[\"Applied Biosystems\",\"CRISPR-Cas9\",\"Gene Editing\",\"GeneArt\",\"Gibco\",\"Invitrogen\",\"PCR\",\"PCR workflow\",\"Real Time PCR\",\"Sanger Sequencing\"],\"articleSection\":[\"Animal Health and AgriGenomics\",\"Developmental Biology\",\"Gene Editing\",\"Infectious Diseases\",\"Product News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/\",\"name\":\"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/cas9-2.jpg\",\"datePublished\":\"2016-06-15T17:26:50+00:00\",\"dateModified\":\"2025-03-12T19:08:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/cas9-2.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/cas9-2.jpg\",\"width\":691,\"height\":346,\"caption\":\"cas9.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/7c9eade775fde6f2d8b4160ac5cc3bae\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/","og_locale":"en_US","og_type":"article","og_title":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground","og_description":"Genome editing is not a new concept to the scientific community and has been around for decades. However, directing precise sequence changes at desired sites has remained a difficult and tedious challenge for researchers. Limited successes have been achieved with oligonucleotides, small molecules, or self-splicing introns, but the development of site-directed zinc finger nucleases (ZFNs)","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-06-15T17:26:50+00:00","article_modified_time":"2025-03-12T19:08:45+00:00","og_image":[{"width":691,"height":346,"url":"http:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"headline":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground","datePublished":"2016-06-15T17:26:50+00:00","dateModified":"2025-03-12T19:08:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/"},"wordCount":1800,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","keywords":["Applied Biosystems","CRISPR-Cas9","Gene Editing","GeneArt","Gibco","Invitrogen","PCR","PCR workflow","Real Time PCR","Sanger Sequencing"],"articleSection":["Animal Health and AgriGenomics","Developmental Biology","Gene Editing","Infectious Diseases","Product News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/","name":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","datePublished":"2016-06-15T17:26:50+00:00","dateModified":"2025-03-12T19:08:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","width":691,"height":346,"caption":"cas9."},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-cas9-genome-editing-guide-finessing-the-technique-and-breaking-new-ground\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"CRISPR-Cas9 Genome Editing Guide \u2013 Finessing the technique and breaking new ground"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/7c9eade775fde6f2d8b4160ac5cc3bae","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":83,"label":"Animal Health and AgriGenomics"},{"value":183,"label":"Developmental Biology"},{"value":2452,"label":"Gene Editing"},{"value":67,"label":"Infectious Diseases"},{"value":101,"label":"Product News"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":126,"label":"CRISPR-Cas9"},{"value":127,"label":"Gene Editing"},{"value":196,"label":"GeneArt"},{"value":197,"label":"Gibco"},{"value":144,"label":"Invitrogen"},{"value":43,"label":"PCR"},{"value":422,"label":"PCR workflow"},{"value":46,"label":"Real Time PCR"},{"value":25,"label":"Sanger Sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg",691,346,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":1,"category_info":[{"term_id":83,"name":"Animal Health and AgriGenomics","slug":"animal-health-and-agrigenomics","term_group":0,"term_taxonomy_id":83,"taxonomy":"category","description":"","parent":0,"count":65,"filter":"raw","meta":[],"cat_ID":83,"category_count":65,"category_description":"","cat_name":"Animal Health and AgriGenomics","category_nicename":"animal-health-and-agrigenomics","category_parent":0},{"term_id":183,"name":"Developmental Biology","slug":"developmental-biology","term_group":0,"term_taxonomy_id":183,"taxonomy":"category","description":"","parent":0,"count":8,"filter":"raw","meta":[],"cat_ID":183,"category_count":8,"category_description":"","cat_name":"Developmental Biology","category_nicename":"developmental-biology","category_parent":0},{"term_id":2452,"name":"Gene Editing","slug":"gene-editing","term_group":0,"term_taxonomy_id":2452,"taxonomy":"category","description":"","parent":0,"count":16,"filter":"raw","meta":[],"cat_ID":2452,"category_count":16,"category_description":"","cat_name":"Gene Editing","category_nicename":"gene-editing","category_parent":0},{"term_id":67,"name":"Infectious Diseases","slug":"infectious-diseases","term_group":0,"term_taxonomy_id":67,"taxonomy":"category","description":"","parent":0,"count":82,"filter":"raw","meta":[],"cat_ID":67,"category_count":82,"category_description":"","cat_name":"Infectious Diseases","category_nicename":"infectious-diseases","category_parent":0},{"term_id":101,"name":"Product News","slug":"product-news","term_group":0,"term_taxonomy_id":101,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":101,"category_count":106,"category_description":"","cat_name":"Product News","category_nicename":"product-news","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":126,"name":"CRISPR-Cas9","slug":"crispr-cas9","term_group":0,"term_taxonomy_id":126,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":127,"name":"Gene Editing","slug":"gene-editing","term_group":0,"term_taxonomy_id":127,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":196,"name":"GeneArt","slug":"geneart","term_group":0,"term_taxonomy_id":196,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":197,"name":"Gibco","slug":"gibco","term_group":0,"term_taxonomy_id":197,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":144,"name":"Invitrogen","slug":"invitrogen","term_group":0,"term_taxonomy_id":144,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":43,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":43,"taxonomy":"post_tag","description":"","parent":0,"count":142,"filter":"raw","meta":[]},{"term_id":422,"name":"PCR workflow","slug":"pcr-workflow","term_group":0,"term_taxonomy_id":422,"taxonomy":"post_tag","description":"","parent":0,"count":24,"filter":"raw","meta":[]},{"term_id":46,"name":"Real Time PCR","slug":"real-time-pcr","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":55,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":8763,"position":0},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":8763,"position":1},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":8763,"position":2},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19776,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/epigenetic-methylation-analysis-qpcr-dpcr\/","url_meta":{"origin":8763,"position":3},"title":"Epigenetics unlocked: How behavior shapes biology","author":"Ashleigh Barlow","date":"May 28, 2026","format":false,"excerpt":"Article Summary Epigenetics is helping researchers understand how environment, behavior, and molecular regulation intersect. Rather than changing the underlying DNA sequence, epigenetic changes influence how genes are expressed, including when they are turned on, turned off, or regulated in response to biological and environmental signals. In this episode of Absolute\u2026","rel":"","context":"In &quot;Epigenetics&quot;","block_context":{"text":"Epigenetics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/epigenetics\/"},"img":{"alt_text":"Portrait of Dr. Robert Philibert discussing epigenetics, DNA methylation, and behavioral biomarkers.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Philibert-Photo_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19566,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/pcr-inhibitors-digital-pcr\/","url_meta":{"origin":8763,"position":4},"title":"When PCR Gets Dirty &#8211; Tackling PCR Inhibitors","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"In this first Absolute Gene-ius: Science Snapshot episode, hosts Jordan Ruggieri and Lisa Crawford revisit expert insights on one persistent molecular biology challenge: PCR inhibitors. Across wastewater surveillance, environmental microbiology, and gene therapy manufacturing, inhibitors can distort PCR data and complicate quantification. Featuring perspectives from Ray Ketchum, PhD; Sarah Philo,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19888,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/streptococcus-pneumoniae-serotype-identification-qpcr-nested-pcr\/","url_meta":{"origin":8763,"position":5},"title":"qPCR, Nested PCR, and the Search for Bacterial Serotypes","author":"Ashleigh Barlow","date":"August 5, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Donna Paznar, former Head of Molecular Infection Diagnostics at the Medical University of Vienna, discusses her research on Streptococcus pneumoniae and its impact across the Austrian population. She explains why children can act as asymptomatic reservoirs, why tracking bacterial serotypes matters, and\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"Donna Paznar discussing molecular methods for identifying Streptococcus pneumoniae serotypes.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Paznar_Headshot_Jordan-Ruggieri-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/cas9-2.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8763","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=8763"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8763\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/8764"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=8763"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=8763"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=8763"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=8763"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}