{"id":8832,"date":"2015-07-15T23:08:23","date_gmt":"2015-07-15T23:08:23","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=8832"},"modified":"2020-09-26T00:13:47","modified_gmt":"2020-09-26T00:13:47","slug":"how-does-fragment-analysis-work-seq-it-out-3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/","title":{"rendered":"How does Fragment Analysis work? \u2013 Seq It Out #3"},"content":{"rendered":"<p><span lang=\"EN-GB\">Do you ever find yourself asking &#8211; &#8220;How does <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/fragment-analysis.html?icid=lsg_gsd_CP1236_PJT8083_blog_seqitout-howfaworks\" target=\"_blank\" rel=\"noopener noreferrer\">fragment analysis<\/a> work and why would one perform fragment analysis in their lab?&#8221;<\/span><\/p>\n<p><span lang=\"EN-GB\">Let&#8217;s check it out.<\/span><\/p>\n<p><iframe loading=\"lazy\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/-RzKFR-n5zs?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p>Fragment analysis refers to a genetic analysis technique used for a wide variety of applications such as mutation detection, genotyping, DNA profiling, genetic mapping and linkage analysis. Various diseases, conditions and chromosomal abnormalities are detected by this method. Traditionally, the DNA fragments are separated by size in a separation matrix like agarose or polyacrylamide gels. Fragment sizes can be determined by comparing to a size standard. Then, fragments are visualized and detected either by labeling them during or after the slab gel electrophoresis using ethidium bromide dye or radioisotopes. But I think you would probably prefer doing something safer like automated capillary electrophoresis which uses fluorescent dyes and separates with higher resolution and higher accuracy.<\/p>\n<p><span lang=\"EN-GB\">To run fragment analysis on a <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html?icid=lsg_gsd_CP1236_PJT8083_blog_seqitout-howfaworks\" target=\"_blank\" rel=\"noopener noreferrer\">capillary electrophoresis system<\/a>, you can design probes and primers to flank your region of interest. Typically fluorescent dyes are attached to the primers or probes and the fragments are amplified by PCR before the electrophoresis. The ladder is usually labelled with a color that is different than the colors of the fragments. The labelled PCR products and the size marker are then electrokinetically injected into the capillaries. During electrophoresis, the negatively charged DNA fragments moves from the cathode, through the polymer-filled capillary towards the positively charged anode when high voltage is applied between the electrodes<\/span><\/p>\n<p><span lang=\"EN-GB\">The really cool thing about fragment analysis is that you can multiplex, meaning you can have multiple fragments in a reaction well going through the same capillary. The smaller fragments usually run faster and the bigger ones run slower. Shortly before reaching the positive electrode, the fluorescently labelled DNA fragments, separated by size, move through the path of a laser beam. The laser beam causes the dyes on the fragments to fluoresce at different emission wavelengths.\u00a0 A CCD camera detects the fluorescence, and the fluorescence intensities are digitalized, color-coded and displayed as peaks in the electrophoregram.<\/span><\/p>\n<p><span lang=\"EN-GB\">Now, that seems pretty neat right? But what\u2019s even more amazing are the various applications for which you can use fragment analysis. <\/span><span lang=\"EN-GB\">One great example is the Single Nucleotide Polymorphism or SNP Genotyping. The SNaPshot Multiplex kit can investigate up to ten SNP markers simultaneously by using primers of different lengths. The primers are designed to anneal to the sequences adjacent to the ten different SNPs.<\/span> <span lang=\"EN-GB\">Once the primer anneals, the single-base extension occurs by the addition of complementary dye terminator, or ddNTP, to the annealed primer. Each of the four ddNTPs is fluorescently labelled with a different color dye. The result is marker fragments for the different SNP alleles that are all the same length, but that vary by color.<\/span><\/p>\n<p><span lang=\"EN-GB\">I hope this video was helpful on fragment analysis, and I am sure you\u2019ll have more questions.<\/span><\/p>\n<p>Submit your question at <a href=\"http:\/\/www.thermofisher.com\/ask?icid=lsg_gsd_CP1236_PJT8083_blog_seqitout-howfaworks\" target=\"_blank\" rel=\"noopener noreferrer\">www.thermofisher.com\/ask<\/a> and subscribe to our channel to see more videos like this.<\/p>\n<p>And remember, when in doubt, just <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/products-and-services\/promotions\/ask.html?icid=lsg_gsd_CP1236_PJT8083_blog_seqitout-howfaworks\" target=\"_blank\" rel=\"noopener noreferrer\">Seq It Out<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Do you ever find yourself asking &#8211; &#8220;How does fragment analysis work and why would one perform fragment analysis in their lab?&#8221; Let&#8217;s check it out. Fragment analysis refers to a genetic analysis technique used for a wide variety of applications such as mutation detection, genotyping, DNA profiling, genetic mapping and linkage analysis. Various diseases,<\/p>\n","protected":false},"author":114,"featured_media":8833,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[108],"tags":[17,36,99,153,43,25,176,74],"division":[],"class_list":["post-8832","post","type-post","status-publish","format-standard","has-post-thumbnail","category-lab-tips-and-tricks","tag-applied-biosystems","tag-capillary-electrophoresis","tag-fragment-analysis","tag-genomic-variants","tag-pcr","tag-sanger-sequencing","tag-seqitout","tag-sequencing","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How does Fragment Analysis work? \u2013 Seq It Out #3 - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How does Fragment Analysis work? \u2013 Seq It Out #3\" \/>\n<meta property=\"og:description\" content=\"Do you ever find yourself asking &#8211; &#8220;How does fragment analysis work and why would one perform fragment analysis in their lab?&#8221; Let&#8217;s check it out. Fragment analysis refers to a genetic analysis technique used for a wide variety of applications such as mutation detection, genotyping, DNA profiling, genetic mapping and linkage analysis. Various diseases,\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-07-15T23:08:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-26T00:13:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"736\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Natalie Gurson\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Natalie Gurson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/\"},\"author\":{\"name\":\"Natalie Gurson\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\"},\"headline\":\"How does Fragment Analysis work? \u2013 Seq It Out #3\",\"datePublished\":\"2015-07-15T23:08:23+00:00\",\"dateModified\":\"2020-09-26T00:13:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/\"},\"wordCount\":527,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/Youtube1-e1466635673650.jpg\",\"keywords\":[\"Applied Biosystems\",\"Capillary Electrophoresis\",\"Fragment Analysis\",\"Genomic Variants\",\"PCR\",\"Sanger Sequencing\",\"SeqitOut\",\"sequencing\"],\"articleSection\":[\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/\",\"name\":\"How does Fragment Analysis work? \u2013 Seq It Out #3 - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/Youtube1-e1466635673650.jpg\",\"datePublished\":\"2015-07-15T23:08:23+00:00\",\"dateModified\":\"2020-09-26T00:13:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/Youtube1-e1466635673650.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/06\\\/Youtube1-e1466635673650.jpg\",\"width\":736,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-does-fragment-analysis-work-seq-it-out-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How does Fragment Analysis work? \u2013 Seq It Out #3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\",\"name\":\"Natalie Gurson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"caption\":\"Natalie Gurson\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/natalie-gurson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How does Fragment Analysis work? \u2013 Seq It Out #3 - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/","og_locale":"en_US","og_type":"article","og_title":"How does Fragment Analysis work? \u2013 Seq It Out #3","og_description":"Do you ever find yourself asking &#8211; &#8220;How does fragment analysis work and why would one perform fragment analysis in their lab?&#8221; Let&#8217;s check it out. Fragment analysis refers to a genetic analysis technique used for a wide variety of applications such as mutation detection, genotyping, DNA profiling, genetic mapping and linkage analysis. Various diseases,","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-07-15T23:08:23+00:00","article_modified_time":"2020-09-26T00:13:47+00:00","og_image":[{"width":736,"height":720,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","type":"image\/jpeg"}],"author":"Natalie Gurson","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Natalie Gurson","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/"},"author":{"name":"Natalie Gurson","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd"},"headline":"How does Fragment Analysis work? \u2013 Seq It Out #3","datePublished":"2015-07-15T23:08:23+00:00","dateModified":"2020-09-26T00:13:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/"},"wordCount":527,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","keywords":["Applied Biosystems","Capillary Electrophoresis","Fragment Analysis","Genomic Variants","PCR","Sanger Sequencing","SeqitOut","sequencing"],"articleSection":["Lab Tips and Tricks"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/","name":"How does Fragment Analysis work? \u2013 Seq It Out #3 - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","datePublished":"2015-07-15T23:08:23+00:00","dateModified":"2020-09-26T00:13:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","width":736,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-does-fragment-analysis-work-seq-it-out-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"How does Fragment Analysis work? \u2013 Seq It Out #3"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd","name":"Natalie Gurson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","caption":"Natalie Gurson"},"url":"https:\/\/admin.acceleratingscience.com\/author\/natalie-gurson\/"}]}},"taxonomy_info":{"category":[{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":36,"label":"Capillary Electrophoresis"},{"value":99,"label":"Fragment Analysis"},{"value":153,"label":"Genomic Variants"},{"value":43,"label":"PCR"},{"value":25,"label":"Sanger Sequencing"},{"value":176,"label":"SeqitOut"},{"value":74,"label":"sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-1024x576.jpg",760,428,true],"author_info":{"display_name":"Natalie Gurson","author_link":"https:\/\/admin.acceleratingscience.com\/author\/natalie-gurson\/"},"comment_info":0,"category_info":[{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":108,"category_count":103,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":36,"name":"Capillary Electrophoresis","slug":"capillary-electrophoresis","term_group":0,"term_taxonomy_id":36,"taxonomy":"post_tag","description":"","parent":0,"count":50,"filter":"raw","meta":[]},{"term_id":99,"name":"Fragment Analysis","slug":"fragment-analysis","term_group":0,"term_taxonomy_id":99,"taxonomy":"post_tag","description":"","parent":0,"count":37,"filter":"raw","meta":[]},{"term_id":153,"name":"Genomic Variants","slug":"genomic-variants","term_group":0,"term_taxonomy_id":153,"taxonomy":"post_tag","description":"","parent":0,"count":69,"filter":"raw","meta":[]},{"term_id":43,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":43,"taxonomy":"post_tag","description":"","parent":0,"count":142,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]},{"term_id":176,"name":"SeqitOut","slug":"seqitout","term_group":0,"term_taxonomy_id":176,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]},{"term_id":74,"name":"sequencing","slug":"sequencing","term_group":0,"term_taxonomy_id":74,"taxonomy":"post_tag","description":"","parent":0,"count":158,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":8832,"position":0},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":8832,"position":1},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19997,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ai-laboratory-automation-qpcr\/","url_meta":{"origin":8832,"position":2},"title":"AI and Laboratory Automation: The experimental context behind qPCR data","author":"Behind The Bench Staff","date":"September 11, 2026","format":false,"excerpt":"AI is changing how researchers analyze biological data, while automation is changing how that data is performed at scale. As more of the research process becomes automated and data-driven, an important question emerges: What should researchers consider about how data is generated before downstream analysis begins? In qPCR, assays, reagents,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"qPCR reaction tube with amplification curves representing experimental data used in AI and laboratory automation.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/qPCR_GEN_Blog_AI_Lab_Automation_Amafel-Calalay.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19943,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dna-and-rna-purity-ratios-a260-a280-and-a260-a230-explained\/","url_meta":{"origin":8832,"position":3},"title":"DNA and RNA Purity Ratios: A260\/A280 and A260\/A230 Explained","author":"Marlene Gasdia-Cochrane","date":"September 1, 2026","format":false,"excerpt":"Overview DNA and RNA purity ratios help researchers assess nucleic acid sample quality before downstream analysis. The A260\/A280 ratio can indicate potential protein contamination, while the A260\/A230 ratio can reveal residual salts, phenol, guanidine compounds, and other extraction-related contaminants. For a more complete assessment, purity ratios should be evaluated alongside\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"mRNA Technology - Messenger RNA - Two Strands of mRNA on Abstract Technology Background - Development of New Therapies and Vaccines Based on mRNA Technology - Conceptual Illustration","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-1366552805_mrna.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":8832,"position":4},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":8832,"position":5},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/06\/Youtube1-e1466635673650.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/114"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=8832"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/8832\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/8833"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=8832"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=8832"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=8832"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=8832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}