{"id":9017,"date":"2016-08-31T05:24:53","date_gmt":"2016-08-31T05:24:53","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=9017"},"modified":"2020-05-28T19:20:30","modified_gmt":"2020-05-28T19:20:30","slug":"normalization-methods-for-mirna-quantitation-ask-taqman-40","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/","title":{"rendered":"Normalization Methods for miRNA Quantitation &#8211; Ask TaqMan #40"},"content":{"rendered":"<p>What do Endogenous Controls, Exogenous Controls and Mean Expression value mean to you?<\/p>\n<p>You guessed it! Today we\u2019re answering your questions about normalization methods for miRNA quantification.<\/p>\n<p><iframe loading=\"lazy\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/pSBG4c79Y_U?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<p>MicroRNAs or miRNAs, are small ~22 nucleotide noncoding RNAs that <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays\/taqman-gene-expression.html?icid=lsg_gsd_CP1188_blog_asktaqman\" target=\"_blank\" rel=\"noopener noreferrer\">regulate gene expression<\/a>. microRNAs can be quantified by real-time PCR using TaqMan assays. In a microRNA expression experiment, variation in the amount of starting material, sample collection, RNA preparation and quality, and reverse transcription efficiency can contribute to quantification errors. For these reasons, it is important to use proper normalization controls when quantifying miRNAs.<\/p>\n<p>There are three types of normalization methods commonly used for miRNA analysis by qPCR &#8211; endogenous controls, exogenous controls and mean expression value normalization, or \u201cglobal mean normalization\u201d<\/p>\n<p>Normalization using endogenous control genes is currently the most accurate method to correct for potential differences in RNA input or RT efficiency biases. Exogenous controls or \u201cspike-ins\u201d are typically used to monitor extraction efficiency or sample input amount for difficult samples such as plasma\/serum or other biofluids. Large scale miRNA expression profiling studies may utilize global mean normalization, which uses the calculated mean of all miRNAs in a given sample as the normalizer.<\/p>\n<p>Historically, non-coding RNAs such as snRNAs and snoRNAs were used as endogenous normalizers for miRNA quantification.<\/p>\n<p>But, more recently, key opinion leaders in the miRNA community have moved away from the use of snoRNAs\/snRNAs as endogenous controls for the following reasons:<\/p>\n<ul>\n<li>They are bigger than miRNAs<\/li>\n<li>They do not \u2018mirror\u2019 the physiochemical properties of miRNA<\/li>\n<li>They have different cellular processing and different functions than miRNAs<\/li>\n<li>The expression levels of snoRNA and snRNA have been recently found to be associated with cancer and prognosis.<\/li>\n<\/ul>\n<p>The miRNA community has also suggested that the ideal endogenous control has gene expression that is relatively constant and moderately abundant across a variety of tissues and cell types and treatment.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9018 \" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-1024x400.png\" alt=\"miRNA Controls\" width=\"714\" height=\"279\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-1024x400.png 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-300x117.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-768x300.png 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-1250x488.png 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/miRNA-Controls-400x156.png 400w\" sizes=\"auto, (max-width: 714px) 100vw, 714px\" \/><\/p>\n<p>miRNAs that are uniformly expressed can be used as an endogenous control. There are several miRNAs that have been shown in the literature and in experimental studies to be expressed at relatively constant levels across many different tissues types (show table). These may work as good endogenous controls for your experimental condition.<\/p>\n<p>By the way, it is recommended to validate 2 or more of these miRNAs as endogenous controls for the target cell, tissue, or treatment that you are using because no single control can act as a universal endogenous control for all experimental conditions.<\/p>\n<p>In addition, synthetic miRNA molecules can be used as spike-in controls and are extremely useful as exogenous controls in difficult samples such as serum\/ plasma.<\/p>\n<p>As the name implies, spike- ins, or exogenous controls are synthetic RNA oligonucleotides that are added to the sample.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9019 \" src=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-1024x369.png\" alt=\"exogenous controls\" width=\"722\" height=\"260\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-1024x369.png 1024w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-300x108.png 300w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-768x277.png 768w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-1250x451.png 1250w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/exogenous-controls-400x144.png 400w\" sizes=\"auto, (max-width: 722px) 100vw, 722px\" \/><\/p>\n<p>A spike-in control should be a target sequence that is not present in your sample. For example, ath-miR-159a (need pronunciation guidance) is not present in humans so it is a good exogenous control for human.<\/p>\n<p>So let\u2019s do a quick recap:<\/p>\n<p>There are 3 different normalization methods, exogenous controls, endogenous controls and mean expression value normalization and these normalization methods allow you to control certain aspects of your experimental process when analyzing miRNAs by qPCR.<\/p>\n<p>If you have more questions on Normalization methods or any burning qPCR questions make sure to let me know and Ask TaqMan at <a href=\"http:\/\/www.thermofisher.com\/ask?cid=social_btb_genequant\">www.thermofisher.com\/ask<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>What do Endogenous Controls, Exogenous Controls and Mean Expression value mean to you? You guessed it! Today we\u2019re answering your questions about normalization methods for miRNA quantification. &nbsp; MicroRNAs or miRNAs, are small ~22 nucleotide noncoding RNAs that regulate gene expression. microRNAs can be quantified by real-time PCR using TaqMan assays. In a microRNA expression<\/p>\n","protected":false},"author":112,"featured_media":9021,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[108],"tags":[17,18,43],"division":[],"class_list":["post-9017","post","type-post","status-publish","format-standard","has-post-thumbnail","category-lab-tips-and-tricks","tag-applied-biosystems","tag-ask-taqman","tag-pcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Normalization Methods for miRNA Quantitation - Ask TaqMan #40 - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Normalization Methods for miRNA Quantitation - Ask TaqMan #40\" \/>\n<meta property=\"og:description\" content=\"What do Endogenous Controls, Exogenous Controls and Mean Expression value mean to you? You guessed it! Today we\u2019re answering your questions about normalization methods for miRNA quantification. &nbsp; MicroRNAs or miRNAs, are small ~22 nucleotide noncoding RNAs that regulate gene expression. microRNAs can be quantified by real-time PCR using TaqMan assays. In a microRNA expression\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-08-31T05:24:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-28T19:20:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"822\" \/>\n\t<meta property=\"og:image:height\" content=\"707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Mike Troutman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mike Troutman\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/\"},\"author\":{\"name\":\"Mike Troutman\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/26f563ac288a574c03a4c61b584bfc83\"},\"headline\":\"Normalization Methods for miRNA Quantitation &#8211; Ask TaqMan #40\",\"datePublished\":\"2016-08-31T05:24:53+00:00\",\"dateModified\":\"2020-05-28T19:20:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/\"},\"wordCount\":569,\"commentCount\":4,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/08\\\/AskTaqMan-40-thumbnail-e1472597344273.jpg\",\"keywords\":[\"Applied Biosystems\",\"Ask TaqMan\",\"PCR\"],\"articleSection\":[\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/\",\"name\":\"Normalization Methods for miRNA Quantitation - Ask TaqMan #40 - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/08\\\/AskTaqMan-40-thumbnail-e1472597344273.jpg\",\"datePublished\":\"2016-08-31T05:24:53+00:00\",\"dateModified\":\"2020-05-28T19:20:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/26f563ac288a574c03a4c61b584bfc83\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/08\\\/AskTaqMan-40-thumbnail-e1472597344273.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/08\\\/AskTaqMan-40-thumbnail-e1472597344273.jpg\",\"width\":822,\"height\":707},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/normalization-methods-for-mirna-quantitation-ask-taqman-40\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Normalization Methods for miRNA Quantitation &#8211; Ask TaqMan #40\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/26f563ac288a574c03a4c61b584bfc83\",\"name\":\"Mike Troutman\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g\",\"caption\":\"Mike Troutman\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mike-troutman\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Normalization Methods for miRNA Quantitation - Ask TaqMan #40 - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/","og_locale":"en_US","og_type":"article","og_title":"Normalization Methods for miRNA Quantitation - Ask TaqMan #40","og_description":"What do Endogenous Controls, Exogenous Controls and Mean Expression value mean to you? You guessed it! Today we\u2019re answering your questions about normalization methods for miRNA quantification. &nbsp; MicroRNAs or miRNAs, are small ~22 nucleotide noncoding RNAs that regulate gene expression. microRNAs can be quantified by real-time PCR using TaqMan assays. In a microRNA expression","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-08-31T05:24:53+00:00","article_modified_time":"2020-05-28T19:20:30+00:00","og_image":[{"width":822,"height":707,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","type":"image\/jpeg"}],"author":"Mike Troutman","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Mike Troutman","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/"},"author":{"name":"Mike Troutman","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/26f563ac288a574c03a4c61b584bfc83"},"headline":"Normalization Methods for miRNA Quantitation &#8211; Ask TaqMan #40","datePublished":"2016-08-31T05:24:53+00:00","dateModified":"2020-05-28T19:20:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/"},"wordCount":569,"commentCount":4,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","keywords":["Applied Biosystems","Ask TaqMan","PCR"],"articleSection":["Lab Tips and Tricks"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/","name":"Normalization Methods for miRNA Quantitation - Ask TaqMan #40 - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","datePublished":"2016-08-31T05:24:53+00:00","dateModified":"2020-05-28T19:20:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/26f563ac288a574c03a4c61b584bfc83"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","width":822,"height":707},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/normalization-methods-for-mirna-quantitation-ask-taqman-40\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Normalization Methods for miRNA Quantitation &#8211; Ask TaqMan #40"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/26f563ac288a574c03a4c61b584bfc83","name":"Mike Troutman","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ce859e4fdb27cef96c23c51bcef1def790ca50e6da0c9b221b2e5bf82b88c5b0?s=96&d=mm&r=g","caption":"Mike Troutman"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mike-troutman\/"}]}},"taxonomy_info":{"category":[{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":18,"label":"Ask TaqMan"},{"value":43,"label":"PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-1024x576.jpg",760,428,true],"author_info":{"display_name":"Mike Troutman","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mike-troutman\/"},"comment_info":5,"category_info":[{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":102,"filter":"raw","meta":[],"cat_ID":108,"category_count":102,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":18,"name":"Ask TaqMan","slug":"ask-taqman","term_group":0,"term_taxonomy_id":18,"taxonomy":"post_tag","description":"","parent":0,"count":18,"filter":"raw","meta":[]},{"term_id":43,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":43,"taxonomy":"post_tag","description":"","parent":0,"count":142,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19911,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-mirna-profiling-precision-oncology\/","url_meta":{"origin":9017,"position":0},"title":"A scalable multiplex miRNA profiling workflow for precision oncology research","author":"Ashleigh Barlow","date":"August 18, 2026","format":false,"excerpt":"The promise of precision oncology rests on our ability to reliably monitor tumor biology in real time. Circulating microRNAs (miRNAs) offer that opportunity, serving as potentially stable, non-invasive biomarkers linked to disease progression and therapeutic response; however, their adoption in routine practice remains constrained by technical hurdles. (1,2) Because cancer\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Scientist pipetting a laboratory sample during molecular biomarker research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19857,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mirna-biomarkers-type-1-diabetes\/","url_meta":{"origin":9017,"position":1},"title":"A pan-continental miRNA profiling study powered by TaqMan qPCR reveals potential new biomarkers for Type 1 Diabetes risk","author":"Ashleigh Barlow","date":"July 28, 2026","format":false,"excerpt":"In conversation with Professor Anandwardhan Hardikar Detecting type 1 diabetes (T1D) before major pancreatic damage occurs remains one of the biggest challenges in the field. By the time most patients are diagnosed, a large proportion of insulin-producing islet \u03b2-cells have already been lost. Traditional markers such as blood glucose or\u2026","rel":"","context":"In &quot;Complex Diseases&quot;","block_context":{"text":"Complex Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/complex-diseases\/"},"img":{"alt_text":"Professor Anandwardhan Hardikar discussing type 1 diabetes biomarker research in front of molecular biology data visualizations.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19976,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/taqman-assay-design-genomic-data\/","url_meta":{"origin":9017,"position":2},"title":"What does it take to keep 20 million Applied Biosystems TaqMan Assays current?","author":"Ashleigh Barlow","date":"September 30, 2026","format":false,"excerpt":"How do you keep more than 20 million TaqMan assays current as genomic knowledge evolves? Every year, our understanding of biology becomes more complete. New variants are discovered, transcript annotations improve, gene models evolve, and our assay-design algorithms advance. That does not mean an assay designed years ago is suddenly\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19271,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","url_meta":{"origin":9017,"position":3},"title":"Multiplex vs. Singleplex qPCR: What do I need to know?","author":"Ashleigh Barlow","date":"December 3, 2025","format":false,"excerpt":"Real-time PCR (qPCR) has transformed how scientists detect and quantify nucleic acid targets, offering analytical sensitivity, speed, and scalability. Many real-time PCR reactions measure a single target per well \u2014 a setup called singleplex qPCR. However, the effectiveness of real-time PCR can be increased by an approach called multiplex qPCR.\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19966,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-assay-optimization-qpcr\/","url_meta":{"origin":9017,"position":4},"title":"Building Better Multiplex Panels: Identifying Assay Interactions Early","author":"Ashleigh Barlow","date":"September 8, 2026","format":false,"excerpt":"Multiplex qPCR has transformed molecular research by enabling scientists to detect multiple targets in a single reaction. The benefits are clear: reduced sample consumption, lower costs, faster workflows, and more data from every experiment. However, designing successful multiplex assays isn't always straightforward. Traditionally, identifying problematic assay combinations required extensive wet-lab\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"For Research Use Only. Not for use in diagnostic procedures. \u00a9 2026 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Header-banner-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19606,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-optimization-6-plex\/","url_meta":{"origin":9017,"position":5},"title":"Optimizing multiplex qPCR: How to amplify up to 6 targets without compromising analytical sensitivity","author":"Behind The Bench Staff","date":"April 1, 2026","format":false,"excerpt":"What happens when a multiplex qPCR assay begins to lose performance as additional targets are introduced? An assay that performs reproducibly in singleplex can exhibit Ct shift, reduced sensitivity, or compressed dynamic range when scaled to 5- or 6-plex. As plex level increases, competition among primers, probes, reporter dyes, and\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Graph comparing Ct values between singleplex and multiplex qPCR reactions showing \u0394Ct shift as targets increase.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/mulitplexing-image.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/08\/AskTaqMan-40-thumbnail-e1472597344273.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9017","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/112"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=9017"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9017\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/9021"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=9017"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=9017"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=9017"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=9017"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}