{"id":9211,"date":"2015-02-11T23:54:22","date_gmt":"2015-02-11T23:54:22","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=9211"},"modified":"2016-12-06T20:30:48","modified_gmt":"2016-12-06T20:30:48","slug":"ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/","title":{"rendered":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis"},"content":{"rendered":"<div class=\"jive-rendered-content\">\n<p>A few months ago <a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/16s-metagenomics-and-straightforward-on-demand-analysis\/\">16S metagenomics<\/a> was highlighted on this blog, where researcher\u2019s 16S custom amplicons can be easily analyzed with a new capability within Ion Reporter. Useful resources, such as the <a class=\"\" href=\"https:\/\/ioncommunity.thermofisher.com\/community\/applications\/metagenomics\">Metagenomics Applications Group<\/a> in the Ion Community and the <a class=\"jive-link-wiki-small\" href=\"https:\/\/ioncommunity.thermofisher.com\/docs\/DOC-8677\">Ion 16S Software Steps for Custom Primers<\/a> are discussed in that prior post.<\/p>\n<p>Historically for microbial identification, for example in the food testing <a href=\"https:\/\/ioncommunity.thermofisher.com\/servlet\/JiveServlet\/showImage\/38-1447-21124\/meta.PNG\"><img loading=\"lazy\" decoding=\"async\" class=\"image-0 jive-image alignright\" src=\"https:\/\/ioncommunity.thermofisher.com\/servlet\/JiveServlet\/downloadImage\/38-1447-21124\/316-129\/meta.PNG\" alt=\"meta.PNG\" width=\"316\" height=\"129\" \/><\/a>industry, pure culture is a requirement. The <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/bioproduction\/microbial-identification-and-detection.html?cid=social_btb_targetseq\" rel=\"nofollow\">MicroSEQ\u00ae ID<\/a>\u00a0 method offers absolute identification and is widely used for many industrial microbiology contexts. From a pure clone, depending on the kit selected (we offer several <a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/en\/US\/adirect\/lt?cmd=catDisplayStyle&amp;catKey=601456&amp;_bcs_=H4sIAAAAAAAAAN1R30%2BDMBD%2Ba3iRuJQiiI%2BbOLNM5wzq61LLAU0KXdpuC%2F%2B9V3CIuhhffDFp7lcv%0A39333XngkWStVb7j1vgejf0M9F5wMD%2FUK2u3Xjj16Bzf4XCYSFGABV41SqpSgJlwVePXzqCBBk2l%0AakCndA56UtlaIopHQ%2FdIYvUOXE4uCbqABNiZUBKcYbYU%2FXhW48SZPzWGtb9fIZwm5DgWPWeW4e9x%0AqecMDcuFBm4xktYL57zOvTBdvNyusDkVZitZe80slEq3uAYWl9Bih9tvzKFg0pwkgS4mwUUUOzb3%0Agmv1Kpj0U7esFaoZkVvk0FhRCBziPhz1P2f6wTKzrcQbxS7t4zDNRFNKuIM9yFMi9MSw8rDGrBDS%0AuuFxHzicFasdzEDboxGdDdS7zJmol8BFYVeYfZaiK3VyHMERtJM4OoocjWU%2BdRV3rcJugrg7SbGh%0AhMZXCR2ukt08IrqGEi%2Fxj1TvaEU9sV7d98anduuagrGkgz7RF4W%2BCfoGTcxuJDcEAAA%3D&amp;OP=filter&amp;filter=ft_6808\/f_2028589*&amp;filterType=1&amp;filterDispName=Capillary+Electrophoresis\" rel=\"nofollow\">types of MicroSeq kits<\/a>), about 500 bases or over 1200 bases are sequenced on a <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/sanger-sequencing.html?cid=social_btb_abseq\" rel=\"nofollow\">capillary electrophoresis Sanger sequencing system<\/a>. Another method for species identification from pure culture uses mass spectroscopy for direct detection of the unique ribosomal proteins.<\/p>\n<p>Until the advent of next-generation sequencing, sequencing an entire population of microbes was not only an enormous effort but also a very expensive undertaking. <a class=\"jive-link-external-small\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15001713\" rel=\"nofollow\">Craig Venter\u2019s \u201cSargasso Sea\u201d paper<\/a> published in 2004 characterized some 1800 species and 1.2 million unknown genes, and that effort took 1.045 billion bases of sequence data.<\/p>\n<p>The ability to sequence 16S ribosomal sequences from an environmental sample is culture-free, and eliminates the bias that may be observed from traditional bacterial culturing techniques. At the spring American Society for Microbiology meeting in Boston, an \u2018ASM Live\u2019 event of researchers at the University of Chicago discussed the fact that urine is not sterile, due to the <a class=\"jive-link-external-small\" href=\"http:\/\/gm.asm.org\/index.php\/scientific-activities\/asm-live\/archives\/565-asm-gm-2014-bacteria-in-urine-could-cause-overactive-bladder\" rel=\"nofollow\">discovery of bacteria that were not culturable but discovered using sequencing<\/a>.<\/p>\n<p>A new kit called the Ion 16S\u2122\u00a0 Metagenomics Kit offers pre-designed multiplex primers for seven of the nine 16S hypervariable regions, eliminating the need for primer design and amplicon pooling, in addition to the greater resolving power (down to the genus and potentially species level) of the larger number of variable regions. Also a kit-specific Environmental Master Mix was developed to help reduce the effect of PCR inhibtors from environmental samples (such as <a class=\"jive-link-external-small\" href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/20971866\" rel=\"nofollow\">humic acids from soil samples<\/a>). Working in conjunction with the Ion Reporter\u2122 4.2 software and use of the <ins cite=\"mailto:Microsoft%20Office%20User\" datetime=\"2014-09-08T16:37\">premium <\/ins>curated MicroSEQ\u00ae ID 16S rRNA reference database (&gt;15,000 organisms) along with the curated GreenGenes database (&gt;400,000 records), a wealth of analysis power in an easy-to-use web interface is now available.<\/p>\n<p>There is a wealth of 16S metagenomics papers already published on the Ion Torrent platform. Now with this new <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/sequencing\/dna-sequencing\/microbial-sequencing\/microbial-identification-ion-torrent-next-generation-sequencing\/ion-16s-metagenomics-solution.html?cid=social_btb_targetseq\" rel=\"nofollow\">Ion 16S\u2122 Metagenomics Kit<\/a> using next-generation sequencing to examine metagenomics is faster, easier and cost-effective. The application note is available on this <a href=\"https:\/\/www.thermofisher.com\/content\/dam\/LifeTech\/Documents\/PDFs\/Ion-16S-Metagenomics-Kit-Software-Application-Note.pdf?cid=social_btb_targetseq\" rel=\"nofollow\">research solution for bacterial identification<\/a> online.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A few months ago 16S metagenomics was highlighted on this blog, where researcher\u2019s 16S custom amplicons can be easily analyzed with a new capability within Ion Reporter. Useful resources, such as the Metagenomics Applications Group in the Ion Community and the Ion 16S Software Steps for Custom Primers are discussed in that prior post. Historically<\/p>\n","protected":false},"author":120,"featured_media":9214,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[184,84],"tags":[103,189,11,6,85],"division":[],"class_list":{"0":"post-9211","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-bioinformatics","8":"category-metagenomics","9":"tag-16s-rrna-microbial","10":"tag-bioinformatics-software","11":"tag-ion-torrent","12":"tag-next-generation-sequencing","13":"tag-whole-genome-sequencing-small-genome","14":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis\" \/>\n<meta property=\"og:description\" content=\"A few months ago 16S metagenomics was highlighted on this blog, where researcher\u2019s 16S custom amplicons can be easily analyzed with a new capability within Ion Reporter. Useful resources, such as the Metagenomics Applications Group in the Ion Community and the Ion 16S Software Steps for Custom Primers are discussed in that prior post. Historically\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-02-11T23:54:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-12-06T20:30:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"707\" \/>\n\t<meta property=\"og:image:height\" content=\"448\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis\",\"datePublished\":\"2015-02-11T23:54:22+00:00\",\"dateModified\":\"2016-12-06T20:30:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/\"},\"wordCount\":430,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/02\\\/biomarker2.png\",\"keywords\":[\"16S rRNA Microbial\",\"Bioinformatics &amp; Software\",\"Ion Torrent\",\"Next Generation Sequencing\",\"Whole Genome Sequencing - Small Genome\"],\"articleSection\":[\"Bioinformatics\",\"Metagenomics\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/\",\"name\":\"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/02\\\/biomarker2.png\",\"datePublished\":\"2015-02-11T23:54:22+00:00\",\"dateModified\":\"2016-12-06T20:30:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/02\\\/biomarker2.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2015\\\/02\\\/biomarker2.png\",\"width\":707,\"height\":448},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/","og_locale":"en_US","og_type":"article","og_title":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis","og_description":"A few months ago 16S metagenomics was highlighted on this blog, where researcher\u2019s 16S custom amplicons can be easily analyzed with a new capability within Ion Reporter. Useful resources, such as the Metagenomics Applications Group in the Ion Community and the Ion 16S Software Steps for Custom Primers are discussed in that prior post. Historically","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-02-11T23:54:22+00:00","article_modified_time":"2016-12-06T20:30:48+00:00","og_image":[{"width":707,"height":448,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","type":"image\/png"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis","datePublished":"2015-02-11T23:54:22+00:00","dateModified":"2016-12-06T20:30:48+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/"},"wordCount":430,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","keywords":["16S rRNA Microbial","Bioinformatics &amp; Software","Ion Torrent","Next Generation Sequencing","Whole Genome Sequencing - Small Genome"],"articleSection":["Bioinformatics","Metagenomics"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/","name":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","datePublished":"2015-02-11T23:54:22+00:00","dateModified":"2016-12-06T20:30:48+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","width":707,"height":448},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/ion-16s-metagenomics-kit-and-ion-reporter-metagenomics-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Ion 16S Metagenomics Kit and Ion Reporter Metagenomics Analysis"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":184,"label":"Bioinformatics"},{"value":84,"label":"Metagenomics"}],"post_tag":[{"value":103,"label":"16S rRNA Microbial"},{"value":189,"label":"Bioinformatics &amp; Software"},{"value":11,"label":"Ion Torrent"},{"value":6,"label":"Next Generation Sequencing"},{"value":85,"label":"Whole Genome Sequencing - Small Genome"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png",707,448,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":184,"name":"Bioinformatics","slug":"bioinformatics","term_group":0,"term_taxonomy_id":184,"taxonomy":"category","description":"","parent":0,"count":20,"filter":"raw","meta":[],"cat_ID":184,"category_count":20,"category_description":"","cat_name":"Bioinformatics","category_nicename":"bioinformatics","category_parent":0},{"term_id":84,"name":"Metagenomics","slug":"metagenomics","term_group":0,"term_taxonomy_id":84,"taxonomy":"category","description":"","parent":0,"count":26,"filter":"raw","meta":[],"cat_ID":84,"category_count":26,"category_description":"","cat_name":"Metagenomics","category_nicename":"metagenomics","category_parent":0}],"tag_info":[{"term_id":103,"name":"16S rRNA Microbial","slug":"16s-rrna-microbial","term_group":0,"term_taxonomy_id":103,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]},{"term_id":189,"name":"Bioinformatics &amp; Software","slug":"bioinformatics-software","term_group":0,"term_taxonomy_id":189,"taxonomy":"post_tag","description":"","parent":0,"count":35,"filter":"raw","meta":[]},{"term_id":11,"name":"Ion Torrent","slug":"ion-torrent","term_group":0,"term_taxonomy_id":11,"taxonomy":"post_tag","description":"","parent":0,"count":167,"filter":"raw","meta":[]},{"term_id":6,"name":"Next Generation Sequencing","slug":"next-generation-sequencing","term_group":0,"term_taxonomy_id":6,"taxonomy":"post_tag","description":"","parent":0,"count":171,"filter":"raw","meta":[]},{"term_id":85,"name":"Whole Genome Sequencing - Small Genome","slug":"whole-genome-sequencing-small-genome","term_group":0,"term_taxonomy_id":85,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":9211,"position":0},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":9211,"position":1},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":9211,"position":2},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19461,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/grapevine-downy-mildew-fungicide-resistance-detection\/","url_meta":{"origin":9211,"position":3},"title":"Tracking grape pathogens from air to vine \u2013 a conversation with Lexi Heger","author":"Behind The Bench Staff","date":"February 28, 2026","format":false,"excerpt":"On the Absolute Gene-ius podcast, Lexi Heger, PhD candidate in Plant Pathology and Molecular Plant Sciences at Michigan State University, explores the molecular detection of grapevine pathogens and how qPCR and digital PCR (dPCR) are transforming plant disease research. Her research centers on downy mildew of grape (Plasmopara viticola) and\u2026","rel":"","context":"In &quot;Animal Health and AgriGenomics&quot;","block_context":{"text":"Animal Health and AgriGenomics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/animal-health-and-agrigenomics\/"},"img":{"alt_text":"Portrait of a smiling plant pathology researcher standing outdoors beside grapevine leaves.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19976,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/taqman-assay-design-genomic-data\/","url_meta":{"origin":9211,"position":4},"title":"What does it take to keep 20 million Applied Biosystems TaqMan Assays current?","author":"Ashleigh Barlow","date":"September 30, 2026","format":false,"excerpt":"How do you keep more than 20 million TaqMan assays current as genomic knowledge evolves? Every year, our understanding of biology becomes more complete. New variants are discovered, transcript annotations improve, gene models evolve, and our assay-design algorithms advance. That does not mean an assay designed years ago is suddenly\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/BAN-16090146_1528x860.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":9211,"position":5},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2015\/02\/biomarker2.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9211","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=9211"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9211\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/9214"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=9211"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=9211"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=9211"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=9211"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}