{"id":9258,"date":"2015-07-31T18:48:45","date_gmt":"2015-07-31T18:48:45","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=9258"},"modified":"2018-10-18T23:38:47","modified_gmt":"2018-10-18T23:38:47","slug":"your-sanger-sequencing-data-analysis-question-seq-it-out","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/","title":{"rendered":"Your Sanger Sequencing Data Analysis Question &#8211; Seq It Out"},"content":{"rendered":"<p>Hi &#8211; Natalie here.<\/p>\n<p>We received a great question from Philip at Kuwait University about terms used when talking about Sanger Sequencing data. I thought you all might be interested in learning more about this topic, so I talked to my friend Mike in our Technical Support group to get a quick lesson on Sanger sequencing data terms.<\/p>\n<p><em>Philip&#8217;s Q: Greetings! I was wondering if you could help us understand the term \u201ctrace\u201d and necessary QC inference from the raw data obtained from capillary electrophoresis? What is the significance of signal strength?\u00a0 What is Trace score, Median PUP, offscale and QV20+?<\/em><\/p>\n<p>A: Hello! To help you understand the data generated from a capillary electrophoresis, let&#8217;s define some of those terms for you:<\/p>\n<p><strong>Trace:<\/strong> The output file from a single lane or capillary on a sequencing instrument that is imported into analysis software such as Sequencing Analysis, Variant Reporter, SeqScape, Variant Analysis module (cloud) or Quality Check module (cloud).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"image-1 jive-image alignright\" src=\"https:\/\/ioncommunity.thermofisher.com\/servlet\/JiveServlet\/downloadImage\/38-1572-27489\/418-230\/Trace_File.jpg\" alt=\"Trace_File.jpg\" width=\"418\" height=\"230\" \/><\/p>\n<p><strong>QV20+:<\/strong> Total number of bases in the entire trace that have a basecaller Quality Value &gt;=20.<\/p>\n<p><strong>Quality Value<\/strong>: A measure of certainty of the basecalling and consensus calling algorithms; high quality value corresponding to a low chance of algorithm error. Trace quality values are the per-base quality values for a trace; consensus quality values are per-consensus quality values (<em>more applicable to Variant Analysis module and Variant Reporter<\/em>).<\/p>\n<p><strong>Trace Score:<\/strong> Average of basecall quality values for bases in the clear range.<\/p>\n<p><em>If you turn trimming on, the clear range is the region of a sequence that remains after excluding the low-quality or error-prone sequences at the 5 prime and 3 prime ends.<\/em><\/p>\n<p><strong>Offscale<\/strong>: saturated data \u2013 At least one data point in the analysis range has saturated the CCD camera.<\/p>\n<p><em>The fluorescent signal is so bright the camera cannot determine how bright it is to accurately represent it as a peak in the trace. It might appear as a split peak or a peak that is flat at the top.<\/em><\/p>\n<p><strong>Median PuP<\/strong>: Measure of noise \u2013 median value within the clear range of the ratio of the main called base\u2019s signal to the signal of the highest secondary peak.<\/p>\n<p>If you look at the video <a href=\"https:\/\/www.youtube.com\/watch?v=e2G5zx-OJIw\" target=\"_blank\" rel=\"nofollow\">How Does Sanger Sequencing Work<\/a> starting at about 1:30, it explains the relationship between ddNTP incorporation and fluorescence. The more ddNTP incorporation events at a particular base position = more fluorescent signal as the DNA migrates through the system. Instrument sensitivity will play a part in the signal intensity. A more sensitive instrument will be able to see DNA signal where there may have been few incorporation events that might ordinarily be lost in baseline noise of the system. However, a more sensitive instrument might also become saturated (defined as having at least one data point in the analysis range that has saturated the CCD Camera), so careful quantitation of the DNA is strongly recommended as part of your optimization process.<\/p>\n<p>For other definitions of terms and how to modify them, you can click on the Actions menu in the Quality Check module in the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/cloud.html?cid=social_btb_abseq\" target=\"_blank\" rel=\"nofollow\">Thermo Fisher Cloud<\/a> and select \u201cQuality Flag Settings\u201d.<\/p>\n<p>I hope that was helpful. If you have more questions on <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/cloud\/all-analysis-modules.html?icid=cloud2#sanger?cid=social_btb_abseq\" target=\"_blank\" rel=\"nofollow\">Sanger Sequencing Data Analysis<\/a>, remember to submit your question at <a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/products-and-services\/promotions\/ask.html?cid=social_abseq\" target=\"_blank\" rel=\"nofollow\">www.thermofisher.com\/ask<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hi &#8211; Natalie here. We received a great question from Philip at Kuwait University about terms used when talking about Sanger Sequencing data. I thought you all might be interested in learning more about this topic, so I talked to my friend Mike in our Technical Support group to get a quick lesson on Sanger<\/p>\n","protected":false},"author":114,"featured_media":9260,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[184,108],"tags":[17,189,25,176,74],"division":[],"class_list":["post-9258","post","type-post","status-publish","format-standard","has-post-thumbnail","category-bioinformatics","category-lab-tips-and-tricks","tag-applied-biosystems","tag-bioinformatics-software","tag-sanger-sequencing","tag-seqitout","tag-sequencing","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Your Sanger Sequencing Data Analysis Question - Seq It Out - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Your Sanger Sequencing Data Analysis Question - Seq It Out\" \/>\n<meta property=\"og:description\" content=\"Hi &#8211; Natalie here. We received a great question from Philip at Kuwait University about terms used when talking about Sanger Sequencing data. I thought you all might be interested in learning more about this topic, so I talked to my friend Mike in our Technical Support group to get a quick lesson on Sanger\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-07-31T18:48:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-10-18T23:38:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1356\" \/>\n\t<meta property=\"og:image:height\" content=\"745\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Natalie Gurson\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Natalie Gurson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/\"},\"author\":{\"name\":\"Natalie Gurson\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\"},\"headline\":\"Your Sanger Sequencing Data Analysis Question &#8211; Seq It Out\",\"datePublished\":\"2015-07-31T18:48:45+00:00\",\"dateModified\":\"2018-10-18T23:38:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/\"},\"wordCount\":547,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/11\\\/Trace_File.jpg\",\"keywords\":[\"Applied Biosystems\",\"Bioinformatics &amp; Software\",\"Sanger Sequencing\",\"SeqitOut\",\"sequencing\"],\"articleSection\":[\"Bioinformatics\",\"Lab Tips and Tricks\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/\",\"name\":\"Your Sanger Sequencing Data Analysis Question - Seq It Out - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/11\\\/Trace_File.jpg\",\"datePublished\":\"2015-07-31T18:48:45+00:00\",\"dateModified\":\"2018-10-18T23:38:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/11\\\/Trace_File.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2016\\\/11\\\/Trace_File.jpg\",\"width\":1356,\"height\":745},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/your-sanger-sequencing-data-analysis-question-seq-it-out\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Your Sanger Sequencing Data Analysis Question &#8211; Seq It Out\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/a3f18baa55031163946eef5147f470bd\",\"name\":\"Natalie Gurson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g\",\"caption\":\"Natalie Gurson\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/natalie-gurson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Your Sanger Sequencing Data Analysis Question - Seq It Out - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/","og_locale":"en_US","og_type":"article","og_title":"Your Sanger Sequencing Data Analysis Question - Seq It Out","og_description":"Hi &#8211; Natalie here. We received a great question from Philip at Kuwait University about terms used when talking about Sanger Sequencing data. I thought you all might be interested in learning more about this topic, so I talked to my friend Mike in our Technical Support group to get a quick lesson on Sanger","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-07-31T18:48:45+00:00","article_modified_time":"2018-10-18T23:38:47+00:00","og_image":[{"width":1356,"height":745,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","type":"image\/jpeg"}],"author":"Natalie Gurson","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Natalie Gurson","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/"},"author":{"name":"Natalie Gurson","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd"},"headline":"Your Sanger Sequencing Data Analysis Question &#8211; Seq It Out","datePublished":"2015-07-31T18:48:45+00:00","dateModified":"2018-10-18T23:38:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/"},"wordCount":547,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","keywords":["Applied Biosystems","Bioinformatics &amp; Software","Sanger Sequencing","SeqitOut","sequencing"],"articleSection":["Bioinformatics","Lab Tips and Tricks"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/","name":"Your Sanger Sequencing Data Analysis Question - Seq It Out - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","datePublished":"2015-07-31T18:48:45+00:00","dateModified":"2018-10-18T23:38:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","width":1356,"height":745},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/your-sanger-sequencing-data-analysis-question-seq-it-out\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Your Sanger Sequencing Data Analysis Question &#8211; Seq It Out"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/a3f18baa55031163946eef5147f470bd","name":"Natalie Gurson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1bcfabe01d929aa52243421e6167d256320bb1f7728f8f77224d50386f16896d?s=96&d=mm&r=g","caption":"Natalie Gurson"},"url":"https:\/\/admin.acceleratingscience.com\/author\/natalie-gurson\/"}]}},"taxonomy_info":{"category":[{"value":184,"label":"Bioinformatics"},{"value":108,"label":"Lab Tips and Tricks"}],"post_tag":[{"value":17,"label":"Applied Biosystems"},{"value":189,"label":"Bioinformatics &amp; Software"},{"value":25,"label":"Sanger Sequencing"},{"value":176,"label":"SeqitOut"},{"value":74,"label":"sequencing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File-1024x563.jpg",760,418,true],"author_info":{"display_name":"Natalie Gurson","author_link":"https:\/\/admin.acceleratingscience.com\/author\/natalie-gurson\/"},"comment_info":3,"category_info":[{"term_id":184,"name":"Bioinformatics","slug":"bioinformatics","term_group":0,"term_taxonomy_id":184,"taxonomy":"category","description":"","parent":0,"count":20,"filter":"raw","meta":[],"cat_ID":184,"category_count":20,"category_description":"","cat_name":"Bioinformatics","category_nicename":"bioinformatics","category_parent":0},{"term_id":108,"name":"Lab Tips and Tricks","slug":"lab-tips-and-tricks","term_group":0,"term_taxonomy_id":108,"taxonomy":"category","description":"","parent":0,"count":102,"filter":"raw","meta":[],"cat_ID":108,"category_count":102,"category_description":"","cat_name":"Lab Tips and Tricks","category_nicename":"lab-tips-and-tricks","category_parent":0}],"tag_info":[{"term_id":17,"name":"Applied Biosystems","slug":"applied-biosystems","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":193,"filter":"raw","meta":[]},{"term_id":189,"name":"Bioinformatics &amp; Software","slug":"bioinformatics-software","term_group":0,"term_taxonomy_id":189,"taxonomy":"post_tag","description":"","parent":0,"count":35,"filter":"raw","meta":[]},{"term_id":25,"name":"Sanger Sequencing","slug":"sanger-sequencing","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":87,"filter":"raw","meta":[]},{"term_id":176,"name":"SeqitOut","slug":"seqitout","term_group":0,"term_taxonomy_id":176,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]},{"term_id":74,"name":"sequencing","slug":"sequencing","term_group":0,"term_taxonomy_id":74,"taxonomy":"post_tag","description":"","parent":0,"count":158,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19885,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/sanger-sequencing-mix-dna-templates\/","url_meta":{"origin":9258,"position":0},"title":"Advancing the Gold Standard: Faster, Smarter, and Built for Challenging Templates","author":"Behind The Bench Staff","date":"August 5, 2026","format":false,"excerpt":"Sanger sequencing has long been the gold standard for accuracy, trusted by laboratories worldwide for applications ranging from plasmid verification to confirming next-generation sequencing results. Yet as research evolves, so do the demands placed on sequencing workflows. Today\u2019s labs are not only looking for accuracy\u2014they need speed, flexibility, and reliable\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"DNA sequencing sample tube with DNA helix and sequencing chromatogram representing Sanger sequencing workflow.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/ChatGPT-Image-Aug-5-2026-09_44_12-AM.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19883,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/building-a-better-sample-qc-workflow-from-extraction-to-sequencing\/","url_meta":{"origin":9258,"position":1},"title":"Building a Better Sample QC Workflow: From Extraction to Sequencing","author":"Marlene Gasdia-Cochrane","date":"August 25, 2026","format":false,"excerpt":"Article Summary Successful genomics experiments don't begin with sequencing\u2014they begin with sample quality. Every downstream application, from PCR to next-generation sequencing (NGS), depends on starting with nucleic acids that are accurately quantified and free from contaminants that could compromise results. Establishing a consistent quality control workflow helps laboratories improve reproducibility\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"A pipette drops a liquid into a petri dish with a dna sequence background, science concept. It suggests medical or genetic research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/iStock-2216731026_petridish-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20004,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/a-guide-to-nucleic-acid-quality-control-dna-and-rna-purity\/","url_meta":{"origin":9258,"position":2},"title":"A Guide to Nucleic Acid Quality Control: DNA and RNA Purity","author":"Marlene Gasdia-Cochrane","date":"September 22, 2026","format":false,"excerpt":"Article Summary Nucleic acid quality control helps researchers evaluate DNA and RNA concentration and purity before downstream applications such as PCR, qPCR, and next-generation sequencing (NGS). A standardized workflow combining reliable extraction, concentration and purity assessment, application-appropriate quantification, and consistent laboratory practices can help identify sample issues early, improve reproducibility,\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Close-up shot of a dna sequence on a screen, a digital representation of genetic code, used for analysis.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/iStock-2212923489_dnasequence-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19345,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/precision-oncology-diagnostics\/","url_meta":{"origin":9258,"position":3},"title":"The Expanding Role of Molecular Diagnostics in Precision Oncology","author":"Behind The Bench Staff","date":"January 13, 2026","format":false,"excerpt":"https:\/\/www.youtube.com\/watch?v=F6FfHIizJBY For Dr. Harald Bartsch, a clinical pathologist in southern Bavaria, molecular diagnostic tools have become an indispensable part of his arsenal. \u201cI believe molecular diagnostics play a crucial role in modern oncology, and I see this as the direction everything is headed,\u201d says Dr. Bartsch. While immunohistochemistry remains central\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Clinical Pathologist in a Molecular Diagnostics Laboratory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":9258,"position":4},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19810,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/integration-site-analysis-gene-therapy-safety\/","url_meta":{"origin":9258,"position":5},"title":"Genotoxicity, vectors, and the power of integration site analysis","author":"Ashleigh Barlow","date":"June 23, 2026","format":false,"excerpt":"Article Summary In this episode of Absolute Gene-ius, Michael Stump, PhD, President of ProtaGene, and Matteo Franco, Lead Scientist at ProtaGene, discuss how integration site analysis is helping researchers evaluate genotoxicity risks in cell and gene therapy workflows. Their conversation explores how viral vectors integrate into the genome, why integration\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Matteo Franco, Lead Scientist at ProtaGene, discussing integration site analysis and genotoxicity assessment","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/FRANCO-headshot_Jordan-Ruggieri.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2016\/11\/Trace_File.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/114"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=9258"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/9258\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/9260"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=9258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=9258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=9258"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=9258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}