{"id":8914,"date":"2017-05-09T11:00:40","date_gmt":"2017-05-09T11:00:40","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/biobanking\/?p=8914"},"modified":"2017-05-09T11:00:40","modified_gmt":"2017-05-09T11:00:40","slug":"the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/","title":{"rendered":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg\" style=\"float: left;margin: 5px\" alt=\"Blood in tube laboratory. Image: Janthiwa Sutthiboriban\/Shutterstock.com.\" height=\"220\" width=\"330\" \/>Differences detected in respective biobank collections are more dependent on preanalytical factors than on the inherent differences among the samples. Therefore, there is a parallel emphasis on standard protocol for biological sample collection and storage and identifying specific&nbsp;biomarkers&nbsp;as quality controls to assess the effects&nbsp;of preanalytical factors on variability in the results.&nbsp;Mateos et al. (2016) used&nbsp;different, complementary proteomic techniques in separate, coordinated laboratories to search for quality biomarkers that would allow assessment of integrity and purity of plasma&nbsp;samples stored in biobanks.<sup>1<\/sup><\/p>\n<p>The authors used blood samples<span class=\"thread\">&nbsp;<\/span>from 100 donors collected by&nbsp;seven different Spanish biobanking facilities with the same standard operating procedures,&nbsp;based on recommendations of the Human&nbsp;Proteome Organization (HUPO). To analyze the effect of preanalytical conditions, they subjected the samples to the following after collection:<\/p>\n<ol>\n<li>A delay of less than four hours at&nbsp;room temperature after blood extraction, simulating&nbsp;the daily routine of a clinical<span class=\"thread\"> laboratory processing<\/span> local&nbsp;samples.<\/li>\n<li>A 24-hour delay at 4&deg;C, reflecting those samples&nbsp;arriving from external laboratories.<\/li>\n<li>Repeated freeze&ndash;thaw cycles to evaluate the effect&nbsp;on plasma protein integrity. Specifically, they subjected samples to one, two and three cycles of freezing and thawing.<\/li>\n<\/ol>\n<p>Before performing proteomic analyses,&nbsp;Mateos et al.&nbsp;pooled the plasma samples<span class=\"thread\"> to deplete them<\/span> of abundant plasma proteins before storing them at &minus;80&deg;C. They then used a shotgun proteomics approach to detect biomarkers in the samples. Specifically, their analyses included <span>solid-phase extraction <\/span>m<span>atrix-assisted laser desorption\/ionization<\/span>&nbsp;time-of-flight (SPE MALDI-TOF), difference gel electrophoresis (DIGE), targeted nano liquid chromatography&ndash;tandem mass spectrometry (nLC-MS\/MS) and shotgun (i<span>sobaric tags for relative and absolute quantitation<\/span> [iTRAQ] and nLC-MALDI TOF\/TOF) proteomic techniques.<\/p>\n<p>Using these approaches, Mateos et al. did not find any significant changes&nbsp;as a result of delays in blood processing or the number of freeze&ndash;thaw cycles. All samples had similar protein distributions except those analyzed by DIGE, in which they found a variation in concentration&nbsp;of several&nbsp;hemoglobin isoforms when there was a delay in blood centrifugation.<\/p>\n<p>This work suggests that blood proteins in plasma may be insensitive to&nbsp;preanalytical variables<span class=\"thread\">&nbsp;such as<\/span> delayed processing and freeze&ndash;thaw cycles when analyzed at the peptide level. Furthermore, the strength in the study comes from the broad set of proteomic approaches that the authors applied. They caution, however, that while their analyses provide strong evidence for blood being immune to preanalytical variables,&nbsp;other analyses, such as immunoassays directed&nbsp;at intact proteins, where collection protocols may have different&nbsp;requirements, may still be affected.<\/p>\n<p><strong>Reference<\/strong><br \/>1. Mateos, J., et al. (2016) &ldquo;<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27620695\" target=\"_blank\">Multicentric study of the effect of pre-analytical variables in the quality of&nbsp;plasma samples stored in biobanks using different complementary&nbsp;proteomic methods<\/a>,&rdquo; Journal of Proteomics [Epub ahead of print],&nbsp;<span>150 (pp. 109&ndash;120), doi: 10.1016\/j.jprot.2016.09.003.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Differences detected in respective biobank collections are more dependent on preanalytical factors than on the inherent differences among the samples. Therefore, there is a parallel emphasis on standard protocol for biological sample collection and storage and identifying specific&nbsp;biomarkers&nbsp;as quality controls to assess the effects&nbsp;of preanalytical factors on variability in the results.&nbsp;Mateos et al. (2016) used&nbsp;different,<\/p>\n","protected":false},"author":7,"featured_media":8913,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[12],"tags":[3,46,10,77,15],"division":[],"class_list":{"0":"post-8914","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-storage-and-transport","8":"tag-best-practices","9":"tag-freezing","10":"tag-sample-integrity","11":"tag-sample-quality","12":"tag-temperature","13":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks<\/title>\n<meta name=\"description\" content=\"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks\" \/>\n<meta property=\"og:description\" content=\"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/\" \/>\n<meta property=\"og:site_name\" content=\"Inside Biobanking\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-09T11:00:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Miriam Pollak\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Miriam Pollak\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/\"},\"author\":{\"name\":\"Miriam Pollak\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/#\\\/schema\\\/person\\\/4059196ff73b52bc1f07844c5f4cc833\"},\"headline\":\"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks\",\"datePublished\":\"2017-05-09T11:00:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/\"},\"wordCount\":499,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2017\\\/05\\\/shutterstock_407116273.jpg\",\"keywords\":[\"best practices\",\"freezing\",\"sample integrity\",\"sample quality\",\"temperature\"],\"articleSection\":[\"Storage and Transport\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/\",\"name\":\"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2017\\\/05\\\/shutterstock_407116273.jpg\",\"datePublished\":\"2017-05-09T11:00:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/#\\\/schema\\\/person\\\/4059196ff73b52bc1f07844c5f4cc833\"},\"description\":\"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2017\\\/05\\\/shutterstock_407116273.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/wp-content\\\/uploads\\\/sites\\\/6\\\/2017\\\/05\\\/shutterstock_407116273.jpg\",\"width\":500,\"height\":334,\"caption\":\"Blood in tube laboratory. Image: Janthiwa Sutthiboriban\\\/Shutterstock.com.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/biobanking\\\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/\",\"name\":\"Inside Biobanking\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/biobanking\\\/#\\\/schema\\\/person\\\/4059196ff73b52bc1f07844c5f4cc833\",\"name\":\"Miriam Pollak\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g\",\"caption\":\"Miriam Pollak\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/miriampollack\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks","description":"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/","og_locale":"en_US","og_type":"article","og_title":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks","og_description":"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.","og_url":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/","og_site_name":"Inside Biobanking","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2017-05-09T11:00:40+00:00","og_image":[{"width":500,"height":334,"url":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","type":"image\/jpeg"}],"author":"Miriam Pollak","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Miriam Pollak","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/"},"author":{"name":"Miriam Pollak","@id":"https:\/\/admin.acceleratingscience.com\/biobanking\/#\/schema\/person\/4059196ff73b52bc1f07844c5f4cc833"},"headline":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks","datePublished":"2017-05-09T11:00:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/"},"wordCount":499,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","keywords":["best practices","freezing","sample integrity","sample quality","temperature"],"articleSection":["Storage and Transport"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/","url":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/","name":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/biobanking\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","datePublished":"2017-05-09T11:00:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/biobanking\/#\/schema\/person\/4059196ff73b52bc1f07844c5f4cc833"},"description":"Mateos et al. used proteomic techniques to search for quality biomarkers that would allow integrity and purity of plasma samples stored in biobanks to be assessed.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","width":500,"height":334,"caption":"Blood in tube laboratory. Image: Janthiwa Sutthiboriban\/Shutterstock.com."},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/biobanking\/the-effect-of-preanalytical-variables-on-plasma-samples-stored-in-biobanks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/biobanking\/"},{"@type":"ListItem","position":2,"name":"The Effect of Preanalytical Variables on Plasma Samples Stored in Biobanks"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/biobanking\/#website","url":"https:\/\/admin.acceleratingscience.com\/biobanking\/","name":"Inside Biobanking","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/biobanking\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/biobanking\/#\/schema\/person\/4059196ff73b52bc1f07844c5f4cc833","name":"Miriam Pollak","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/138c71d1874bdfb2f1009601f81ea94eacf7e42948fb85dfbf21aaf3bfafbe1d?s=96&d=mm&r=g","caption":"Miriam Pollak"},"url":"https:\/\/admin.acceleratingscience.com\/author\/miriampollack\/"}]}},"taxonomy_info":{"category":[{"value":12,"label":"Storage and Transport"}],"post_tag":[{"value":3,"label":"best practices"},{"value":46,"label":"freezing"},{"value":10,"label":"sample integrity"},{"value":77,"label":"sample quality"},{"value":15,"label":"temperature"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg",500,334,false],"author_info":{"display_name":"Miriam Pollak","author_link":"https:\/\/admin.acceleratingscience.com\/author\/miriampollack\/"},"comment_info":6,"category_info":[{"term_id":12,"name":"Storage and Transport","slug":"storage-and-transport","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":48,"filter":"raw","meta":[],"cat_ID":12,"category_count":48,"category_description":"","cat_name":"Storage and Transport","category_nicename":"storage-and-transport","category_parent":0}],"tag_info":[{"term_id":3,"name":"best practices","slug":"best-practices","term_group":0,"term_taxonomy_id":3,"taxonomy":"post_tag","description":"","parent":0,"count":46,"filter":"raw","meta":[]},{"term_id":46,"name":"freezing","slug":"freezing","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":10,"name":"sample integrity","slug":"sample-integrity","term_group":0,"term_taxonomy_id":10,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":77,"name":"sample quality","slug":"sample-quality","term_group":0,"term_taxonomy_id":77,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":15,"name":"temperature","slug":"temperature","term_group":0,"term_taxonomy_id":15,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/biobanking\/wp-content\/uploads\/sites\/6\/2017\/05\/shutterstock_407116273.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/posts\/8914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/comments?post=8914"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/posts\/8914\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/media\/8913"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/media?parent=8914"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/categories?post=8914"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/tags?post=8914"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/biobanking\/wp-json\/wp\/v2\/division?post=8914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}