{"id":2236,"date":"2025-03-21T11:00:05","date_gmt":"2025-03-21T17:00:05","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/?p=2236"},"modified":"2025-02-11T17:48:23","modified_gmt":"2025-02-11T23:48:23","slug":"el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/","title":{"rendered":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro"},"content":{"rendered":"<p><span style=\"font-weight: 400\">Por<\/span><a href=\"https:\/\/www.thermofisher.com\/blog\/author\/marlenegasdiacochrane-0\/\"> <span style=\"font-weight: 400\">Marlene Gasdia-Cochrane<\/span><\/a><\/p>\n<p><span style=\"font-weight: 400\">La<\/span><a href=\"https:\/\/www.royalmint.com\/aboutus\/press-centre\/new-factory-extracting-gold-from-e-waste-unveiled-by-the-royal-mint\/\"> <span style=\"font-weight: 400\">Real Casa de la Moneda<\/span><\/a><span style=\"font-weight: 400\"> acaba de anunciar que ha construido una nueva f\u00e1brica pionera que proporciona una fuente de oro m\u00e1s sostenible y reduce la dependencia de la miner\u00eda. Una nueva instalaci\u00f3n extraer\u00e1 oro de las placas de circuitos impresos (PCB) que se encuentran en art\u00edculos de uso cotidiano, como televisores, ordenadores port\u00e1tiles y tel\u00e9fonos m\u00f3viles, en cuesti\u00f3n de minutos.<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400\">\u00abLa f\u00e1brica ha llevado la innovadora tecnolog\u00eda del laboratorio a un nivel industrial por primera vez y tiene capacidad para procesar hasta 4000 toneladas de PCB procedentes de residuos electr\u00f3nicos cada a\u00f1o. Proporciona a la empresa m\u00e1s antigua del Reino Unido una nueva forma m\u00e1s sostenible de \u00abextraer\u00bb oro de alta calidad con una pureza de 999,9. El oro recuperado ya se est\u00e1 utilizando en la colecci\u00f3n de joyer\u00eda de lujo 886 de The Royal Mint.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Seg\u00fan el Monitor Mundial de Residuos Electr\u00f3nicos de las Naciones Unidas, la generaci\u00f3n de residuos electr\u00f3nicos en todo el mundo aumenta en 2,6 millones de toneladas cada a\u00f1o. En 2022 se produjo una cifra r\u00e9cord de 62 millones de toneladas de residuos electr\u00f3nicos, un 82 % m\u00e1s que en 2010\u00bb.<\/span><\/p><\/blockquote>\n<p><span style=\"font-weight: 400\">El Programa de Ciclos Sostenibles (SCYCLE) del Instituto de las Naciones Unidas para Formaci\u00f3n Profesional e Investigaciones (<\/span><a href=\"https:\/\/ewastemonitor.info\/electronic-waste-rising-five-times-faster-than-documeted-e-waste-recycling-un\/\"><span style=\"font-weight: 400\">UNITAR)<\/span><\/a><span style=\"font-weight: 400\"> inform\u00f3 de que la generaci\u00f3n mundial de residuos electr\u00f3nicos est\u00e1 aumentando cinco veces m\u00e1s r\u00e1pido que el reciclaje documentado de residuos electr\u00f3nicos. \u00abEn 2022 se produjo un r\u00e9cord de 62 millones de toneladas (Mt) de desechos electr\u00f3nicos, un 82 % m\u00e1s que en 2010; en camino de aumentar otro 32 %, hasta los 82 millones de toneladas, en 2030; miles de millones de d\u00f3lares en recursos estrat\u00e9gicamente valiosos desperdiciados, vertidos; solo el 1 % de la demanda de elementos de tierras raras se satisface con el reciclaje de desechos electr\u00f3nicos&#8230; En todo el mundo, la generaci\u00f3n anual de residuos electr\u00f3nicos est\u00e1 aumentando en 2,6 millones de toneladas al a\u00f1o, en camino de alcanzar los 82 millones de toneladas en 2030, un aumento adicional del 33 % con respecto a la cifra de 2022\u00bb.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2237 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png\" alt=\"\" width=\"1869\" height=\"495\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png 1869w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301-300x79.png 300w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301-1024x271.png 1024w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301-768x203.png 768w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301-1536x407.png 1536w\" sizes=\"auto, (max-width: 1869px) 100vw, 1869px\" \/><\/p>\n<h2><b>Se necesitan m\u00e1s programas de reciclaje<\/b><\/h2>\n<p><span style=\"font-weight: 400\">La<\/span><a href=\"http:\/\/www.ncsl.org\/research\/environment-and-natural-resources\/e-waste-recycling-legislation.aspx\"> <span style=\"font-weight: 400\">Conferencia Nacional de Legislaturas Estatales<\/span><\/a><span style=\"font-weight: 400\"> cit\u00f3 hace varios a\u00f1os las numerosas razones por las que m\u00e1s estados de EE. UU. deber\u00edan tener programas de reciclaje de residuos electr\u00f3nicos, entre ellas:<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400\">\u00abLa producci\u00f3n de dispositivos electr\u00f3nicos requiere una cantidad significativa de recursos (metales, pl\u00e1sticos y vidrio), muchos de los cuales pueden recuperarse mediante el reciclaje. Por ejemplo, la producci\u00f3n de un ordenador de sobremesa requiere al menos 240 kg de combustibles f\u00f3siles, 22 kg de productos qu\u00edmicos y 1,5 toneladas de agua. Los tel\u00e9fonos m\u00f3viles tambi\u00e9n consumen muchos recursos, ya que est\u00e1n compuestos por metales preciosos como plata, oro, paladio y cobre. La recuperaci\u00f3n de estos y otros materiales mediante el reciclaje utiliza una fracci\u00f3n de la energ\u00eda necesaria para extraer nuevos metales.<\/span><\/p><\/blockquote>\n<p><span style=\"font-weight: 400\">Adem\u00e1s, la presencia de materiales peligrosos como el plomo, el n\u00edquel y el mercurio en algunos aparatos electr\u00f3nicos hace que su eliminaci\u00f3n segura sea especialmente importante. Estos metales podr\u00edan suponer un riesgo para la salud humana o el medio ambiente si no se manipulan correctamente\u00bb.<\/span><\/p>\n<p><span style=\"font-weight: 400\">La cuesti\u00f3n de la abundancia de residuos electr\u00f3nicos fue tan preocupante que la EPA lanz\u00f3 un<\/span><a href=\"https:\/\/www.epa.gov\/smm-electronics\/sustainable-materials-management-smm-electronics-challenge-recognition-and-awards\"> <span style=\"font-weight: 400\">desaf\u00edo electr\u00f3nico<\/span><\/a><span style=\"font-weight: 400\"> para que los estados se replantearan la forma habitual de hacer negocios y se comprometieran a una gesti\u00f3n innovadora y responsable de los productos electr\u00f3nicos al final de su vida \u00fatil. Sin embargo, todav\u00eda hay algunos problemas en la recuperaci\u00f3n de los metales, como se\u00f1alamos en<\/span><a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/thinking-about-the-new-iphone-x-dont-forget-to-recycle-your-old-cell-phone-heres-how?icid=CAD_blog_metals_2024Aug\"> <span style=\"font-weight: 400\">\u00bfPensando en el nuevo iPhone X?<\/span> <span style=\"font-weight: 400\">No olvide reciclar su tel\u00e9fono m\u00f3vil antiguo. As\u00ed es como&#8230;<\/span><\/a><span style=\"font-weight: 400\"> Muchos de los aparatos electr\u00f3nicos que acaban en desguaces e instalaciones de reciclaje de metales se trituran y se combinan con otros metales, lo que hace imposible determinar el contenido exacto sin un an\u00e1lisis cuidadoso.<\/span><\/p>\n<h3><b>Utilizaci\u00f3n de la tecnolog\u00eda XRF para ayudar a encontrar metales preciosos en las instalaciones de reciclaje<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Saber qu\u00e9 hay dentro de ese mont\u00f3n de material triturado es crucial para los beneficios y la seguridad de las operaciones de chatarra. Hace varios a\u00f1os, la EPA cit\u00f3 algunos<\/span><a href=\"https:\/\/www.epa.gov\/smm-electronics\/frequent-questions-about-sustainable-materials-management-smm-electronics-challenge\"> <span style=\"font-weight: 400\">ejemplos de<\/span><\/a><span style=\"font-weight: 400\"> c\u00f3mo el reciclaje de residuos electr\u00f3nicos puede ser una bendici\u00f3n:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Una tonelada m\u00e9trica de placas de circuitos puede contener de 40 a 800 veces la cantidad de oro y de 30 a 40 veces la cantidad de cobre extra\u00eddos de una tonelada m\u00e9trica de mineral en los EE. UU.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Las instalaciones de reciclaje pueden recuperar 35 000 libras de cobre, 772 libras de plata, 75 libras de oro y 33 libras de paladio por cada mill\u00f3n de tel\u00e9fonos m\u00f3viles (PDF)<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400\">Adem\u00e1s, en los dep\u00f3sitos de reciclaje se pueden encontrar muchos<\/span><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/posters\/Infographic-Rare-Earth-Elements.pdf?icid=CAD_blog_metals_2024Aug\"> <span style=\"font-weight: 400\">elementos de tierras raras (ETR)<\/span><\/a><span style=\"font-weight: 400\">, ya que son componentes fundamentales en tel\u00e9fonos m\u00f3viles y otros productos electr\u00f3nicos de consumo, como televisores, ordenadores y c\u00e1maras, as\u00ed como en imanes de alta potencia, l\u00e1mparas fluorescentes, convertidores catal\u00edticos y aleaciones met\u00e1licas. (Los elementos de tierras raras no son realmente raros, pero son extremadamente dif\u00edciles y costosos de extraer, por lo que el reciclaje ha sido una alternativa viable). Los elementos de tierras raras tambi\u00e9n se conocen como los \u00abelementos verdes\u00bb porque son esenciales para muchas tecnolog\u00edas de energ\u00eda verde, como las bater\u00edas de los coches h\u00edbridos y las turbinas e\u00f3licas.<\/span><\/p>\n<p><span style=\"font-weight: 400\">La clasificaci\u00f3n r\u00e1pida y precisa de la chatarra es una parte fundamental de la operaci\u00f3n del dep\u00f3sito de chatarra para aumentar la recuperaci\u00f3n de materiales reutilizables, de modo que el metal pueda venderse para su refabricaci\u00f3n en nuevos productos. Estos<\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/portable-scrap-metal-recycling-analysis.html?icid=CAD_blog_metals_2019Aug\"> <span style=\"font-weight: 400\">recicladores de chatarra<\/span><\/a><span style=\"font-weight: 400\"> probablemente saben lo que encontrar\u00e1n en productos que a\u00fan est\u00e1n intactos, pero si los dispositivos est\u00e1n triturados podr\u00eda haber cualquier cantidad de metales en cantidades variables, junto con materiales peligrosos.<\/span><\/p>\n<p><span style=\"font-weight: 400\">En estas situaciones, los<\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/niton-xl5-handheld-analyzer.html\"> <span style=\"font-weight: 400\">analizadores port\u00e1tiles de fluorescencia de rayos X (XRF)<\/span><\/a><span style=\"font-weight: 400\"> son la mejor manera de identificar positivamente numerosas aleaciones, analizar r\u00e1pidamente su composici\u00f3n qu\u00edmica en los puntos de transferencia de materiales y garantizar la calidad de su producto a sus clientes. Estos<\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/portable-scrap-metal-recycling-analysis.html?icid=CAD_blog_metals_2024Aug#menu2\"> <span style=\"font-weight: 400\">port\u00e1tiles analizadores XRF<\/span><\/a><span style=\"font-weight: 400\"> pueden ayudar a detectar si los componentes electr\u00f3nicos, incluidos los acabados de las placas de circuitos impresos (PCB), los cables, las terminaciones, la soldadura y las interconexiones internas\/externas, contienen sustancias restringidas, y ayudan a garantizar que las sustancias t\u00f3xicas, como el plomo, el mercurio y el cadmio, se mantengan fuera del flujo de reciclaje y de los productos futuros.<\/span><\/p>\n<h3><b>Cuidado con la contaminaci\u00f3n por radiaci\u00f3n en las instalaciones de reciclaje<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Adem\u00e1s de los analizadores port\u00e1tiles, tambi\u00e9n existen<\/span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/ASMIV3KE?icid=CAD_blog_metals_2024Aug\"> <span style=\"font-weight: 400\">sistemas de control de chatarra<\/span><\/a><span style=\"font-weight: 400\"> que supervisan los veh\u00edculos que entran en el dep\u00f3sito de chatarra, o los procesos dentro de las instalaciones, y proporcionan una detecci\u00f3n precisa y fiable de las fuentes de radiaci\u00f3n que se encuentran habitualmente en la chatarra. El sistema ayuda a los operadores de los dep\u00f3sitos de chatarra a rechazar los materiales radiactivos antes de que entren en el flujo de reciclaje y luego da\u00f1en a las personas o al medio ambiente.<\/span><\/p>\n<p><span style=\"font-weight: 400\">No creo que los aparatos electr\u00f3nicos desaparezcan pronto, pero tal vez, con la ayuda de m\u00e1s empresas que sigan el ejemplo de la Casa de la Moneda Real, veamos m\u00e1s componentes electr\u00f3nicos triturados, clasificados, fundidos y transformados en nuevos dispositivos, joyas y otros art\u00edculos.<\/span><\/p>\n<h4><b>Lectura adicional<\/b><\/h4>\n<ul>\n<li style=\"font-weight: 400\"><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/portable-scrap-metal-recycling-analysis.html?icid=CAD_blog_metals_2024Aug\"><span style=\"font-weight: 400\">Soluciones port\u00e1tiles de reciclaje de chatarra<\/span><\/a><\/li>\n<li style=\"font-weight: 400\"><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Product-Information\/ten-reasons-recyclers-need-radiation-detection-infographic.pdf\"><i><span style=\"font-weight: 400\">Infograf\u00eda: 10 razones (y lugares) por las que los recicladores necesitan detecci\u00f3n de radiaci\u00f3n<\/span><\/i><\/a><\/li>\n<li style=\"font-weight: 400\"><a href=\"https:\/\/players.brightcove.net\/665001591001\/I9XluuSon_default\/index.html?videoId=6350523815112\"><span style=\"font-weight: 400\">V\u00eddeo: 30 a\u00f1os de analizadores XRF port\u00e1tiles Niton<\/span><\/a><\/li>\n<\/ul>\n<p><i><span style=\"font-weight: 400\">Nota del editor: Este art\u00edculo fue publicado originalmente el 3 de septiembre de 2019, bajo el autor Tim Johnson, pero ha sido actualizado con informaci\u00f3n actualizada.<\/span><\/i><\/p>\n<p><a href=\"https:\/\/players.brightcove.net\/665001591001\/I9XluuSon_default\/index.html?videoId=6350523815112\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2238\" src=\"http:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/webimage-A2A2B9B4-6D97-4BBC-895DDB46DEE57624.png\" alt=\"\" width=\"701\" height=\"146\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/webimage-A2A2B9B4-6D97-4BBC-895DDB46DEE57624.png 600w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/webimage-A2A2B9B4-6D97-4BBC-895DDB46DEE57624-300x63.png 300w\" sizes=\"auto, (max-width: 701px) 100vw, 701px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Por Marlene Gasdia-Cochrane La Real Casa de la Moneda acaba de anunciar que ha construido una nueva f\u00e1brica pionera que proporciona una fuente de oro m\u00e1s sostenible y reduce la dependencia de la miner\u00eda. Una nueva instalaci\u00f3n extraer\u00e1 oro de las placas de circuitos impresos (PCB) que se encuentran en art\u00edculos de uso cotidiano, como<\/p>\n","protected":false},"author":1127,"featured_media":2237,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[4],"tags":[],"division":[],"class_list":{"0":"post-2236","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-metales","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>El estado del reciclaje de residuos electr\u00f3nicos para obtener oro - Ciencia Acelerada<\/title>\n<meta name=\"description\" content=\"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro\" \/>\n<meta property=\"og:description\" content=\"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/\" \/>\n<meta property=\"og:site_name\" content=\"Ciencia Acelerada\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-21T17:00:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1869\" \/>\n\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Alexis Perrusquia\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alexis Perrusquia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/\"},\"author\":{\"name\":\"Alexis Perrusquia\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/32c31b7cc689abc3e0177475b8c4ddab\"},\"headline\":\"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro\",\"datePublished\":\"2025-03-21T17:00:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/\"},\"wordCount\":1358,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/02\\\/Captura-de-pantalla-2025-02-11-173301.png\",\"articleSection\":[\"Metales\"],\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/\",\"name\":\"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro - Ciencia Acelerada\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/02\\\/Captura-de-pantalla-2025-02-11-173301.png\",\"datePublished\":\"2025-03-21T17:00:05+00:00\",\"description\":\"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#breadcrumb\"},\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/02\\\/Captura-de-pantalla-2025-02-11-173301.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/02\\\/Captura-de-pantalla-2025-02-11-173301.png\",\"width\":1869,\"height\":495},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/metales\\\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"name\":\"Ciencia Acelerada\",\"description\":\"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.\",\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-MX\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\",\"name\":\"Thermo Fisher Scientific\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"width\":1024,\"height\":231,\"caption\":\"Thermo Fisher Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ThermoFisherLatinAmerica\",\"https:\\\/\\\/x.com\\\/thermofisherla\",\"https:\\\/\\\/www.instagram.com\\\/thermofisherscientific\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/thermo-fisher-scientific\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCfUs2fCDhx07fkszsJ0jOcA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/32c31b7cc689abc3e0177475b8c4ddab\",\"name\":\"Alexis Perrusquia\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"caption\":\"Alexis Perrusquia\"},\"sameAs\":[\"https:\\\/\\\/cad.kapost.com\\\/users\\\/perrusquia-alexis-r\",\"alexis.perrusquia@thermofiher.com\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/perrusquiaalexisr\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro - Ciencia Acelerada","description":"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/","og_locale":"es_MX","og_type":"article","og_title":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro","og_description":"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.","og_url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/","og_site_name":"Ciencia Acelerada","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","article_published_time":"2025-03-21T17:00:05+00:00","og_image":[{"width":1869,"height":495,"url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","type":"image\/png"}],"author":"Alexis Perrusquia","twitter_card":"summary_large_image","twitter_creator":"@thermofisherla","twitter_site":"@thermofisherla","twitter_misc":{"Escrito por":"Alexis Perrusquia","Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/"},"author":{"name":"Alexis Perrusquia","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/32c31b7cc689abc3e0177475b8c4ddab"},"headline":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro","datePublished":"2025-03-21T17:00:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/"},"wordCount":1358,"commentCount":0,"publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","articleSection":["Metales"],"inLanguage":"es-MX","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/","url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/","name":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro - Ciencia Acelerada","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","datePublished":"2025-03-21T17:00:05+00:00","description":"Los Elementos de Tierras Raras (ETR) son vitales, pero su extracci\u00f3n es costosa y dif\u00edcil. Aprenda sobre el desaf\u00edo de obtener estos elementos esenciales de forma sostenible a trav\u00e9s del reciclaje.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#breadcrumb"},"inLanguage":"es-MX","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/"]}]},{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","width":1869,"height":495},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/metales\/el-estado-del-reciclaje-de-residuos-electronicos-para-obtener-oro\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/"},{"@type":"ListItem","position":2,"name":"El estado del reciclaje de residuos electr\u00f3nicos para obtener oro"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","name":"Ciencia Acelerada","description":"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.","publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-MX"},{"@type":"Organization","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization","name":"Thermo Fisher Scientific","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","logo":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","width":1024,"height":231,"caption":"Thermo Fisher Scientific"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","https:\/\/x.com\/thermofisherla","https:\/\/www.instagram.com\/thermofisherscientific\/","https:\/\/www.linkedin.com\/company\/thermo-fisher-scientific\/","https:\/\/www.youtube.com\/channel\/UCfUs2fCDhx07fkszsJ0jOcA"]},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/32c31b7cc689abc3e0177475b8c4ddab","name":"Alexis Perrusquia","image":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","caption":"Alexis Perrusquia"},"sameAs":["https:\/\/cad.kapost.com\/users\/perrusquia-alexis-r","alexis.perrusquia@thermofiher.com"],"url":"https:\/\/admin.acceleratingscience.com\/author\/perrusquiaalexisr\/"}]}},"taxonomy_info":{"category":[{"value":4,"label":"Metales"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301-1024x271.png",760,201,true],"author_info":{"display_name":"Alexis Perrusquia","author_link":"https:\/\/admin.acceleratingscience.com\/author\/perrusquiaalexisr\/"},"comment_info":0,"category_info":[{"term_id":4,"name":"Metales","slug":"metales","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":77,"filter":"raw","meta":[],"cat_ID":4,"category_count":77,"category_description":"","cat_name":"Metales","category_nicename":"metales","category_parent":0}],"tag_info":false,"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/02\/Captura-de-pantalla-2025-02-11-173301.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/users\/1127"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/comments?post=2236"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2236\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media\/2237"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media?parent=2236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/categories?post=2236"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/tags?post=2236"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/division?post=2236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}