{"id":2779,"date":"2025-09-09T11:00:00","date_gmt":"2025-09-09T17:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/?p=2779"},"modified":"2025-09-03T19:17:09","modified_gmt":"2025-09-04T01:17:09","slug":"episodio-1-beneficios-de-la-deteccion-por-aerosol","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/","title":{"rendered":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)"},"content":{"rendered":"<div class=\"is-default-size wp-block-site-logo\"><a href=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/\" class=\"custom-logo-link\" rel=\"home\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"231\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png\" class=\"custom-logo\" alt=\"Ciencia Acelerada\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png 1024w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_-300x68.png 300w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_-768x173.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/div>\n\n\n<p><strong>Por Marcus Klee, Gerente Regional de Marketing<\/strong><strong><br><\/strong><\/p>\n\n\n\n<p>La cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC, por sus siglas en ingl\u00e9s) es una t\u00e9cnica fundamental en la qu\u00edmica anal\u00edtica, ampliamente utilizada para separar, identificar y cuantificar componentes en mezclas complejas. Si bien detectores tradicionales como UV-Vis y espectrometr\u00eda de masas (MS) han sido el est\u00e1ndar durante d\u00e9cadas, la <a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/liquid-chromatography-lc\/hplc-uhplc-components\/hplc-uhplc-detectors.html\"><strong>detecci\u00f3n por aerosol cargado (CAD)<\/strong><\/a> est\u00e1 emergiendo como una alternativa poderosa y vers\u00e1til. En esta publicaci\u00f3n, exploramos los principios del CAD, sus ventajas y c\u00f3mo est\u00e1 transformando el panorama de la qu\u00edmica anal\u00edtica.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png\" alt=\"\" class=\"wp-image-2781\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png 1024w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1-300x150.png 300w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1-768x384.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-que-es-la-deteccion-por-aerosol-cargado-cad\"><strong>\u00bfQu\u00e9 es la Detecci\u00f3n por Aerosol Cargado (CAD)?<\/strong><\/h2>\n\n\n\n<p>La detecci\u00f3n por aerosol cargado es un tipo de detector universal utilizado en HPLC que ofrece una respuesta constante para analitos no vol\u00e1tiles y semivol\u00e1tiles. A diferencia de los detectores UV-Vis, que requieren crom\u00f3foros espec\u00edficos, o la espectrometr\u00eda de masas, cuya respuesta puede variar seg\u00fan el compuesto, el CAD proporciona una respuesta m\u00e1s uniforme en una amplia gama de analitos. Esto lo hace especialmente \u00fatil en aplicaciones donde otras t\u00e9cnicas de detecci\u00f3n no resultan efectivas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-como-funciona-el-cad\"><strong>\u00bfC\u00f3mo funciona el CAD?<\/strong><\/h2>\n\n\n\n<p>El funcionamiento del CAD puede dividirse en cuatro etapas principales:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Nebulizaci\u00f3n:<\/strong> El eluyente l\u00edquido que sale de la columna HPLC se convierte en un aerosol fino mediante un nebulizador, generando peque\u00f1as gotas que contienen el analito.<br><\/li>\n\n\n\n<li><strong>Evaporaci\u00f3n:<\/strong> El aerosol pasa a trav\u00e9s de un tubo calentado donde se evapora el disolvente, dejando part\u00edculas secas del analito.<br><\/li>\n\n\n\n<li><strong>Carga:<\/strong> Las part\u00edculas secas se cargan al pasar por una descarga de corona.<br><\/li>\n\n\n\n<li><strong>Detecci\u00f3n:<\/strong> Un electr\u00f3metro mide las part\u00edculas cargadas y produce una se\u00f1al que se correlaciona con la concentraci\u00f3n del analito.<br><\/li>\n<\/ol>\n\n\n\n<p>Esta secuencia permite detectar una gran variedad de compuestos con alta sensibilidad y consistencia.<\/p>\n\n\n\n<p class=\"has-text-align-center\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"340\" src=\"https:\/\/admin.acceleratingscience.com\/47599c06-27b1-46d3-a0fa-ff82bb003783\"><\/p>\n\n\n\n<p>Puede encontrar m\u00e1s informaci\u00f3n en el video de tecnolog\u00eda CAD: <a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection.html\">Ver video sobre la tecnolog\u00eda CAD<\/a><\/p>\n\n\n\n<p><strong>Beneficios de la Detecci\u00f3n por Aerosol Cargado<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Detecci\u00f3n universal:<\/strong> Puede detectar cualquier compuesto no vol\u00e1til y muchos semivol\u00e1tiles, lo que la hace m\u00e1s vers\u00e1til que los detectores UV-Vis que requieren grupos funcionales espec\u00edficos.<br><\/li>\n\n\n\n<li><strong>Respuesta constante:<\/strong> A diferencia de la espectrometr\u00eda de masas, cuya respuesta puede variar seg\u00fan la estructura qu\u00edmica, el CAD ofrece una se\u00f1al m\u00e1s uniforme, lo que simplifica la cuantificaci\u00f3n y mejora la confiabilidad.<br><\/li>\n\n\n\n<li><strong>Alta sensibilidad:<\/strong> Con l\u00edmites de detecci\u00f3n en el rango de nanogramos, es ideal para an\u00e1lisis traza.<br><\/li>\n\n\n\n<li><strong>Robustez:<\/strong> Es menos sensible a los efectos de matriz, brindando datos confiables incluso en muestras complejas.<br><\/li>\n\n\n\n<li><strong>Facilidad de uso:<\/strong> Es f\u00e1cil de operar y mantener, lo que lo hace accesible para una amplia gama de laboratorios.<br><\/li>\n<\/ul>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detection-benefits.html\">Conozca m\u00e1s <\/a>sobre los beneficios del an\u00e1lisis HPLC-CAD<\/p>\n\n\n\n<p><br><strong>Aplicaciones del CAD<\/strong><\/p>\n\n\n\n<p>La versatilidad del CAD ha impulsado su adopci\u00f3n en diversas industrias:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detector-cad-literature-references.html\"><strong>Farmac\u00e9utica<\/strong><\/a><strong>:<\/strong> Utilizado para el perfil de impurezas, pruebas de estabilidad y cuantificaci\u00f3n de ingredientes farmac\u00e9uticos activos (APIs). Su respuesta constante lo hace ideal para estos an\u00e1lisis.<br><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detector-cad-literature-references.html\"><strong>Alimentos y bebidas<\/strong><\/a><strong>:<\/strong> Permite analizar aditivos, contaminantes y componentes nutricionales, incluso en niveles traza.<br><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detector-cad-literature-references.html\"><strong>An\u00e1lisis ambiental<\/strong><\/a><strong>:<\/strong> Empleado en la detecci\u00f3n de contaminantes y monitoreo de muestras ambientales, es eficaz incluso en matrices complejas.<br><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detector-cad-literature-references.html\"><strong>Biotecnolog\u00eda<\/strong><\/a><strong>:<\/strong> \u00datil en el an\u00e1lisis de biomol\u00e9culas como p\u00e9ptidos, prote\u00ednas y oligonucle\u00f3tidos, gracias a su capacidad para detectar una amplia gama de compuestos.<br><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-estudio-de-caso-cad-en-analisis-farmaceutico\"><strong>Estudio de caso: CAD en an\u00e1lisis farmac\u00e9utico<\/strong><\/h2>\n\n\n\n<p>El CAD ha demostrado ser una herramienta poderosa en el an\u00e1lisis farmac\u00e9utico, superando m\u00e9todos tradicionales como UV-Vis y espectrometr\u00eda de masas. Mientras que UV-Vis presenta limitaciones con compuestos sin crom\u00f3foros, y la MS puede verse afectada por supresi\u00f3n i\u00f3nica, el CAD proporciona detecci\u00f3n constante y confiable en una amplia gama de compuestos.<\/p>\n\n\n\n<p>En un estudio de formulaci\u00f3n farmac\u00e9utica compleja, el CAD logr\u00f3 detectar y cuantificar m\u00faltiples impurezas que no eran f\u00e1cilmente identificables con UV-Vis o MS. Esta capacidad garantiz\u00f3 la calidad y seguridad del producto final y simplific\u00f3 el flujo de trabajo anal\u00edtico al reducir la necesidad de m\u00faltiples t\u00e9cnicas de detecci\u00f3n.<\/p>\n\n\n\n<p>El Departamento de Farmacia de la Universidad de Wuerzburg implement\u00f3 exitosamente el CAD, encontrando que ofrece mayor sensibilidad y precisi\u00f3n que m\u00e9todos basados en dispersi\u00f3n de luz o \u00edndice de refracci\u00f3n. Adem\u00e1s, el CAD complementa la detecci\u00f3n UV en t\u00e9cnicas acopladas y experimentos preliminares antes de la identificaci\u00f3n por MS. Integrado con el sistema <a href=\"https:\/\/www.thermofisher.com\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/liquid-chromatography-lc\/hplc-uhplc-systems\/vanquish-flex-uhplc-system.html\"><strong>Thermo Scientific\u2122 Vanquish\u2122 Flex UHPLC<\/strong><\/a>, permite un an\u00e1lisis integral que combina las fortalezas de m\u00faltiples tecnolog\u00edas en un solo flujo de trabajo.<\/p>\n\n\n\n<p><strong>En resumen<\/strong>, el CAD mejora el an\u00e1lisis farmac\u00e9utico al proporcionar una sensibilidad y confiabilidad excepcionales para el perfil de impurezas, contribuyendo a garantizar la seguridad y eficacia de los medicamentos.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"397\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image.png\" alt=\"\" class=\"wp-image-2780\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image.png 768w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-300x155.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n<p><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Reference-Materials\/cs-001444-pb-cad-drug-safety-wuerzburg-cs001444-na-en.pdf\">Conozca m\u00e1s<\/a> sobre este caso de \u00e9xito<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\"><strong>Conclusi\u00f3n<\/strong><\/h2>\n\n\n\n<p>La Detecci\u00f3n por Aerosol Cargado est\u00e1 revolucionando el HPLC al ofrecer un m\u00e9todo de detecci\u00f3n universal, sensible y robusto. Su capacidad para detectar una amplia gama de compuestos con respuesta consistente lo convierte en una herramienta indispensable en diversas industrias. A medida que los desaf\u00edos anal\u00edticos evolucionan, el CAD se destaca como una soluci\u00f3n confiable y vers\u00e1til que ampl\u00eda los l\u00edmites de lo que puede lograrse con HPLC.<\/p>\n\n\n\n<p>Ya sea que usted sea una persona experta en qu\u00edmica anal\u00edtica o que reci\u00e9n est\u00e9 comenzando en el campo, incorporar el CAD en su flujo de trabajo de HPLC puede mejorar significativamente sus capacidades anal\u00edticas y ofrecer una comprensi\u00f3n m\u00e1s profunda de sus muestras. Con el avance de la tecnolog\u00eda, el CAD est\u00e1 destinado a desempe\u00f1ar un papel cada vez m\u00e1s relevante en el futuro de la qu\u00edmica anal\u00edtica.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Por Marcus Klee, Gerente Regional de Marketing La cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC, por sus siglas en ingl\u00e9s) es una t\u00e9cnica fundamental en la qu\u00edmica anal\u00edtica, ampliamente utilizada para separar, identificar y cuantificar componentes en mezclas complejas. Si bien detectores tradicionales como UV-Vis y espectrometr\u00eda de masas (MS) han sido el est\u00e1ndar durante d\u00e9cadas,<\/p>\n","protected":false},"author":1127,"featured_media":2781,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155,156],"tags":[],"division":[],"class_list":{"0":"post-2779","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cromatografia-avanzada","8":"category-hplc","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC) - Ciencia Acelerada<\/title>\n<meta name=\"description\" content=\"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)\" \/>\n<meta property=\"og:description\" content=\"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/\" \/>\n<meta property=\"og:site_name\" content=\"Ciencia Acelerada\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-09T17:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"512\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Alexis Perrusquia\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alexis Perrusquia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/\"},\"author\":{\"name\":\"Alexis Perrusquia\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/32c31b7cc689abc3e0177475b8c4ddab\"},\"headline\":\"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)\",\"datePublished\":\"2025-09-09T17:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/\"},\"wordCount\":1026,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/09\\\/image-1.png\",\"articleSection\":[\"Cromatograf\u00eda Avanzada\",\"HPLC\"],\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/\",\"name\":\"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC) - Ciencia Acelerada\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/09\\\/image-1.png\",\"datePublished\":\"2025-09-09T17:00:00+00:00\",\"description\":\"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#breadcrumb\"},\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/09\\\/image-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/09\\\/image-1.png\",\"width\":1024,\"height\":512},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/cromatografia-avanzada\\\/episodio-1-beneficios-de-la-deteccion-por-aerosol\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"name\":\"Ciencia Acelerada\",\"description\":\"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.\",\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-MX\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\",\"name\":\"Thermo Fisher Scientific\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"width\":1024,\"height\":231,\"caption\":\"Thermo Fisher Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ThermoFisherLatinAmerica\",\"https:\\\/\\\/x.com\\\/thermofisherla\",\"https:\\\/\\\/www.instagram.com\\\/thermofisherscientific\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/thermo-fisher-scientific\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCfUs2fCDhx07fkszsJ0jOcA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/32c31b7cc689abc3e0177475b8c4ddab\",\"name\":\"Alexis Perrusquia\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g\",\"caption\":\"Alexis Perrusquia\"},\"sameAs\":[\"https:\\\/\\\/cad.kapost.com\\\/users\\\/perrusquia-alexis-r\",\"alexis.perrusquia@thermofiher.com\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/perrusquiaalexisr\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC) - Ciencia Acelerada","description":"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/","og_locale":"es_MX","og_type":"article","og_title":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)","og_description":"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.","og_url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/","og_site_name":"Ciencia Acelerada","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","article_published_time":"2025-09-09T17:00:00+00:00","og_image":[{"width":1024,"height":512,"url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","type":"image\/png"}],"author":"Alexis Perrusquia","twitter_card":"summary_large_image","twitter_creator":"@thermofisherla","twitter_site":"@thermofisherla","twitter_misc":{"Escrito por":"Alexis Perrusquia","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/"},"author":{"name":"Alexis Perrusquia","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/32c31b7cc689abc3e0177475b8c4ddab"},"headline":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)","datePublished":"2025-09-09T17:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/"},"wordCount":1026,"commentCount":0,"publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","articleSection":["Cromatograf\u00eda Avanzada","HPLC"],"inLanguage":"es-MX","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/","url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/","name":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC) - Ciencia Acelerada","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","datePublished":"2025-09-09T17:00:00+00:00","description":"Descubre la cromatograf\u00eda l\u00edquida de alta resoluci\u00f3n (HPLC) con detecci\u00f3n por aerosol cargado (CAD). Aprende c\u00f3mo esta innovadora t\u00e9cnica est\u00e1 revolucionando la qu\u00edmica anal\u00edtica al complementar los detectores tradicionales y mejorar la separaci\u00f3n y cuantificaci\u00f3n de compuestos.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#breadcrumb"},"inLanguage":"es-MX","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/"]}]},{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","width":1024,"height":512},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/cromatografia-avanzada\/episodio-1-beneficios-de-la-deteccion-por-aerosol\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/"},{"@type":"ListItem","position":2,"name":"Episodio 1: Beneficios de la Detecci\u00f3n por Aerosol Cargado (CAD) en la Cromatograf\u00eda L\u00edquida de Alta Resoluci\u00f3n (HPLC)"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","name":"Ciencia Acelerada","description":"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.","publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-MX"},{"@type":"Organization","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization","name":"Thermo Fisher Scientific","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","logo":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","width":1024,"height":231,"caption":"Thermo Fisher Scientific"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","https:\/\/x.com\/thermofisherla","https:\/\/www.instagram.com\/thermofisherscientific\/","https:\/\/www.linkedin.com\/company\/thermo-fisher-scientific\/","https:\/\/www.youtube.com\/channel\/UCfUs2fCDhx07fkszsJ0jOcA"]},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/32c31b7cc689abc3e0177475b8c4ddab","name":"Alexis Perrusquia","image":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/efc96b217228576116ece763a0b73ab6ae1dfcafe848001871d0c9e66e7c9bc8?s=96&d=mm&r=g","caption":"Alexis Perrusquia"},"sameAs":["https:\/\/cad.kapost.com\/users\/perrusquia-alexis-r","alexis.perrusquia@thermofiher.com"],"url":"https:\/\/admin.acceleratingscience.com\/author\/perrusquiaalexisr\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"Cromatograf\u00eda Avanzada"},{"value":156,"label":"HPLC"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png",760,380,false],"author_info":{"display_name":"Alexis Perrusquia","author_link":"https:\/\/admin.acceleratingscience.com\/author\/perrusquiaalexisr\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"Cromatograf\u00eda Avanzada","slug":"cromatografia-avanzada","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":33,"filter":"raw","meta":[],"cat_ID":155,"category_count":33,"category_description":"","cat_name":"Cromatograf\u00eda Avanzada","category_nicename":"cromatografia-avanzada","category_parent":0},{"term_id":156,"name":"HPLC","slug":"hplc","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":155,"count":4,"filter":"raw","meta":[],"cat_ID":156,"category_count":4,"category_description":"","cat_name":"HPLC","category_nicename":"hplc","category_parent":155}],"tag_info":false,"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/09\/image-1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/users\/1127"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/comments?post=2779"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2779\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media\/2781"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media?parent=2779"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/categories?post=2779"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/tags?post=2779"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/division?post=2779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}