{"id":2825,"date":"2025-10-21T11:00:00","date_gmt":"2025-10-21T17:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/?p=2825"},"modified":"2025-10-14T17:35:01","modified_gmt":"2025-10-14T23:35:01","slug":"principios-y-capacidades-de-la-reologia-de-polvos","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/","title":{"rendered":"Principios y capacidades de la reolog\u00eda de polvos"},"content":{"rendered":"<div class=\"is-default-size wp-block-site-logo\"><a href=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/\" class=\"custom-logo-link\" rel=\"home\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"231\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png\" class=\"custom-logo\" alt=\"Ciencia Acelerada\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png 1024w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_-300x68.png 300w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_-768x173.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/div>\n\n\n<p>Escrito por<a href=\"https:\/\/www.thermofisher.com\/blog\/?p=956\"> Birgit Schroeder<\/a> <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"274\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-1024x274.png\" alt=\"\" class=\"wp-image-2826\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-1024x274.png 1024w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-300x80.png 300w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-768x206.png 768w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-1536x412.png 1536w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png 1877w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/rheometry-viscometry\/accessories\/powder-rheology-accessories.html?icid=CAD_blog_materials_2025Sept#introduction\">La reolog\u00eda de polvos<\/a> es una t\u00e9cnica anal\u00edtica fundamental para varias industrias, entre ellas la alimentaria, la farmac\u00e9utica, el desarrollo de bater\u00edas y los pol\u00edmeros. Este tipo de an\u00e1lisis examina el comportamiento del flujo y las propiedades mec\u00e1nicas de los materiales en polvo, que difieren fundamentalmente de los de los l\u00edquidos y semis\u00f3lidos. Los l\u00edquidos fluyen con suavidad debido a las fuerzas intermoleculares m\u00e1s d\u00e9biles entre las part\u00edculas, que permiten que sus mol\u00e9culas se deslicen unas sobre otras. Los polvos, por otro lado, fluyen a medida que sus peque\u00f1as part\u00edculas se mueven e interact\u00faan entre s\u00ed y con su recipiente, mostrando a menudo propiedades tanto de s\u00f3lidos como de fluidos.<\/p>\n\n\n\n<p>Comprender el comportamiento del flujo de los polvos es esencial para optimizar los procesos de producci\u00f3n y garantizar la calidad de los productos finales. En esta entrada del blog, exploraremos los principios cient\u00edficos que subyacen a la reolog\u00eda de los polvos y destacaremos las capacidades t\u00e9cnicas de las t\u00e9cnicas reol\u00f3gicas avanzadas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-principios-cientificos-de-la-reologia-de-los-polvos\"><strong>Principios cient\u00edficos de la reolog\u00eda de los polvos<\/strong><\/h2>\n\n\n\n<p>La reolog\u00eda de los polvos se centra en comprender c\u00f3mo se comportan los polvos bajo diferentes tensiones y condiciones ambientales. Dado que las propiedades de flujo de los polvos dependen de su estado de compresi\u00f3n y, en ocasiones, de su historial de compresi\u00f3n, saber c\u00f3mo se comportar\u00e1n los polvos en determinadas condiciones puede proporcionar informaci\u00f3n sobre c\u00f3mo se podr\u00edan ajustar las operaciones para manejar mejor los materiales y mejorar los procesos de producci\u00f3n.<\/p>\n\n\n\n<p>Hay cuatro principios clave que se tienen en cuenta en la reolog\u00eda de los polvos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Fluidez<\/strong>: se refiere a la facilidad con la que las part\u00edculas de un polvo pueden deslizarse unas sobre otras o moverse a lo largo de una superficie. La fluidez se ve influida por factores como el tama\u00f1o de las part\u00edculas, su forma y su contenido de humedad. Es una caracter\u00edstica fundamental para aquellos procesos en los que es necesario un suministro constante de material, como la extrusi\u00f3n.<\/li>\n\n\n\n<li><strong>Compresibilidad<\/strong>: la compresibilidad mide c\u00f3mo disminuye el volumen de un polvo bajo presi\u00f3n. Durante su manipulaci\u00f3n, todos los polvos experimentan cierto nivel de carga compresiva. Esto ocurre no solo durante la etapa de compresi\u00f3n propiamente dicha, sino tambi\u00e9n durante el proceso de alimentaci\u00f3n o transporte. La compresibilidad es crucial para aplicaciones como la producci\u00f3n de gr\u00e1nulos o la fabricaci\u00f3n de comprimidos farmac\u00e9uticos, en las que los polvos deben compactarse en formas s\u00f3lidas sin comprometer su integridad.<\/li>\n\n\n\n<li><strong>Cohesi\u00f3n<\/strong>: indica la tendencia de las part\u00edculas a adherirse entre s\u00ed. Una alta cohesi\u00f3n puede provocar aglomeraci\u00f3n o formaci\u00f3n de grumos. Esta propiedad tambi\u00e9n puede afectar a la fluidez de un polvo y dificultar su procesamiento.<\/li>\n\n\n\n<li><strong>Resistencia al cizallamiento<\/strong>: es la resistencia del polvo a la deformaci\u00f3n por cizallamiento. La tensi\u00f3n de cizallamiento puede hacer que los planos paralelos de un material se deslicen entre s\u00ed, lo que podr\u00eda provocar un cambio en la forma del material sin alterar su volumen. La capacidad de un polvo para resistir esta fuerza de cizallamiento es un par\u00e1metro esencial para comprender c\u00f3mo se comportar\u00e1n los polvos bajo tensiones mec\u00e1nicas, como la mezcla o la manipulaci\u00f3n.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-capacidades-tecnicas-de-la-reologia-de-los-polvos\"><strong>Capacidades t\u00e9cnicas de la reolog\u00eda de los polvos<\/strong><\/h2>\n\n\n\n<p>Los<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/379-0700?icid=CAD_blog_materials_2025Sept\"> re\u00f3metros<\/a> modernos vienen con una gama de<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/rheometry-viscometry\/accessories\/powder-rheology-accessories.html?icid=CAD_blog_materials_2025Sept\"> accesorios especializados<\/a> para realizar pruebas reol\u00f3gicas espec\u00edficas de polvos. La informaci\u00f3n detallada que proporcionan estos diversos componentes puede permitir a los fabricantes optimizar sus procesos. Las mediciones se relacionan directamente con los cuatro principios clave de la reolog\u00eda mencionados anteriormente:<\/p>\n\n\n\n<p><strong>Prueba de fluidez de polvos<\/strong>: esta prueba eval\u00faa la fluidez de los polvos midiendo la resistencia al movimiento de un<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/222-2632?icid=CAD_blog_materials_2025Sept\"> rotor de cuchillas retorcidas<\/a>. A diferencia de las geometr\u00edas tradicionales de los re\u00f3metros, como las placas paralelas o el cono y la placa, que son adecuadas para l\u00edquidos y algunos semis\u00f3lidos, la pala retorcida puede moverse helicoidalmente a trav\u00e9s de una muestra de polvo. Se miden el par y la fuerza necesarios para mover el rotor a trav\u00e9s de la muestra, y los datos se utilizan para calcular la energ\u00eda de fluidez total sin confinar y confinada de la muestra de polvo. Se determinan par\u00e1metros como la energ\u00eda de fluidez b\u00e1sica y la estabilidad del flujo, que son cruciales para procesos como la fabricaci\u00f3n aditiva y la producci\u00f3n de lodos para bater\u00edas.<\/p>\n\n\n\n<p><strong>Ensayo de compresi\u00f3n de polvos<\/strong>: eval\u00faa la compresibilidad y la densidad de los polvos. Un accesorio de rotor especializado para ensayos de compresi\u00f3n no es un rotor tradicional, sino que es el nombre que recibe la parte m\u00f3vil del accesorio de compresi\u00f3n que aplica la fuerza y provoca la deformaci\u00f3n. Se coloca una muestra en una copa especialmente dise\u00f1ada y se mueve el rotor para comprimir el polvo dentro de los l\u00edmites de la copa. Se miden la fuerza aplicada y la deformaci\u00f3n resultante y se utilizan para informar a los investigadores sobre las cualidades del polvo que se est\u00e1 estudiando. Por ejemplo, en la producci\u00f3n de polvos de grafito para electrodos de bater\u00edas, los ensayos de compresi\u00f3n ayudan a determinar las condiciones \u00f3ptimas para obtener una calidad constante de la pasta.<\/p>\n\n\n\n<p><strong>Ensayo de cizallamiento de polvos<\/strong>: Mide la resistencia al cizallamiento y la cohesi\u00f3n de los polvos. El polvo se consolida en una c\u00e9lula de cizallamiento, o una copa con una base perfilada sobre una placa superior perfilada, y luego la muestra se cizalla lentamente bajo tensiones normales variables hasta que cede. Este proceso informa sobre la cohesi\u00f3n, el l\u00edmite el\u00e1stico, la funci\u00f3n de flujo y otras propiedades.<\/p>\n\n\n\n<p><strong>Influencia del contenido de humedad<\/strong>: El contenido de humedad afecta significativamente a la fluidez del polvo. Los re\u00f3metros pueden caracterizar el comportamiento de flujo de los polvos a diferentes niveles de humedad, lo que ayuda a optimizar procesos como la extrusi\u00f3n de alimentos, en los que las variaciones de humedad pueden afectar a la textura y al rendimiento del producto.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-aplicaciones-de-la-reologia-de-polvos-en-la-industria\"><strong>Aplicaciones de la reolog\u00eda de polvos en la industria<\/strong><\/h2>\n\n\n\n<p>La reolog\u00eda de polvos tiene diversas aplicaciones en m\u00faltiples industrias:<\/p>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/materials-science-research\/additive-manufacturing.html?icid=CAD_blog_materials_2025Sept\"><strong>Fabricaci\u00f3n aditiva<\/strong><\/a>: Los procesos de fusi\u00f3n de lecho de polvo (PBF) consisten en esparcir un material en polvo con el espesor de capa deseado sobre un sustrato y, a continuaci\u00f3n, fundir el polvo para fusionarlo en una pieza cohesionada. Comprender la fluidez y la densidad del polvo es esencial para controlar la densidad de las capas y producir piezas de alta calidad. Las pruebas reol\u00f3gicas ayudan a garantizar que los polvos met\u00e1licos se esparzan de manera uniforme y se compacten adecuadamente, lo que reduce la rugosidad de la superficie y mejora la integridad de las piezas.<\/p>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/materials-science\/battery-research\/extrusion-rheology-battery-manufacturing.html?icid=CAD_blog_materials_2025Sept\"><strong>Fabricaci\u00f3n de bater\u00edas<\/strong><\/a>: Las pastas de electrodos se pueden producir mediante mezcla por lotes, en la que se combinan cantidades precisas de polvo de grafito, aglutinante, disolvente y aditivos en un recipiente de mezcla, o mediante mezcla continua en un proceso de extrusi\u00f3n, que ofrece eficiencia y un rendimiento constante para la producci\u00f3n a gran escala. El polvo de grafito es esencial en la producci\u00f3n de pastas de \u00e1nodo para bater\u00edas de iones de litio debido a su excelente conductividad el\u00e9ctrica, estabilidad y capacidad para intercalar iones de litio. Hay dos tipos principales de grafito que se utilizan en la fabricaci\u00f3n de \u00e1nodos: el grafito natural y el sint\u00e9tico. A veces se utilizan mezclas de grafito natural y sint\u00e9tico para equilibrar el costo y optimizar las caracter\u00edsticas del \u00e1nodo. Conocer las propiedades reol\u00f3gicas de los polvos de grafito, incluyendo la fluidez, la compresibilidad y la resistencia al cizallamiento, puede ser fundamental para lograr un procesamiento \u00f3ptimo. El uso de un re\u00f3metro rotacional equipado con un accesorio dise\u00f1ado espec\u00edficamente para investigaciones reol\u00f3gicas de polvos ayuda a proporcionar los conocimientos necesarios para optimizar las propiedades de flujo de cualquier mezcla de grafito.<\/p>\n\n\n\n<p><strong>Procesamiento de alimentos<\/strong>: Cuando se utilizan con una<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/food-beverage\/food-solutions-rheology-extrusion.html?icid=CAD_blog_materials_2025Sept\"> t\u00e9cnica de producci\u00f3n de alimentos como la extrusi\u00f3n<\/a>, las t\u00e9cnicas reol\u00f3gicas pueden utilizarse para caracterizar, por ejemplo, la fluidez del polvo de almid\u00f3n de papa con mayor contenido de humedad en relaci\u00f3n con su capacidad de alimentaci\u00f3n para los procesos de extrusi\u00f3n de alimentos. La fluidez de los materiales granulares depende en gran medida de la forma y el tama\u00f1o de las part\u00edculas, as\u00ed como de las propiedades de la superficie de las part\u00edculas, entre otros aspectos. Adem\u00e1s, se debe tener en cuenta el contenido de humedad de los materiales: a medida que aumenta el contenido de humedad, tienden a formarse puentes l\u00edquidos entre las part\u00edculas. Esto puede provocar aglomeraci\u00f3n, lo que aumenta la cohesi\u00f3n y reduce la fluidez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-resumen\"><strong>Resumen<\/strong><\/h2>\n\n\n\n<p>La reolog\u00eda de polvos es un campo vital que combina principios cient\u00edficos con capacidades t\u00e9cnicas avanzadas para optimizar los procesos industriales. Al comprender y controlar el comportamiento de flujo, la compresibilidad y la cohesi\u00f3n de los polvos, los fabricantes pueden mejorar la calidad de los productos y la eficiencia de los procesos. Los re\u00f3metros modernos, equipados con accesorios especializados, proporcionan una visi\u00f3n completa de las propiedades de los polvos, lo que los convierte en herramientas indispensables en diversas industrias.<\/p>\n\n\n\n<p>Ya sea en la fabricaci\u00f3n aditiva, la producci\u00f3n de bater\u00edas o el procesamiento de alimentos, la aplicaci\u00f3n de la reolog\u00eda de polvos ayuda a garantizar que estos se comporten de forma predecible y consistente, lo que se traduce en mejores productos y procesos m\u00e1s eficientes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-recursos-adicionales\"><strong>Recursos adicionales<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nota de aplicaci\u00f3n:<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/powder-rheology-in-powder-additive-manufacturing-ppa-v312-en.pdf?icid=CAD_blog_materials_2025Sept\"> Reolog\u00eda de polvos en la fabricaci\u00f3n aditiva basada en lechos de polvo<\/a><\/li>\n\n\n\n<li>Nota de aplicaci\u00f3n:<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/influence-of-moisture-content-ppa-v312.pdf?icid=CAD_blog_materials_2025Sept\"> Influencia del contenido de humedad en la fluidez del polvo durante la alimentaci\u00f3n<\/a><\/li>\n\n\n\n<li>Nota de aplicaci\u00f3n:<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/investigation-of-pharmaceutical-powders-v315.pdf?icid=CAD_blog_materials_2025Sept\"> Investigaci\u00f3n de los efectos de la consolidaci\u00f3n de los polvos farmac\u00e9uticos<\/a><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"125\" src=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/MC-Service-Plan-Visual-Identity-Rheometers-eSig-banner-1995300-600x125-2.jpg\" alt=\"\" class=\"wp-image-2827\" srcset=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/MC-Service-Plan-Visual-Identity-Rheometers-eSig-banner-1995300-600x125-2.jpg 600w, https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/MC-Service-Plan-Visual-Identity-Rheometers-eSig-banner-1995300-600x125-2-300x63.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Escrito por Birgit Schroeder La reolog\u00eda de polvos es una t\u00e9cnica anal\u00edtica fundamental para varias industrias, entre ellas la alimentaria, la farmac\u00e9utica, el desarrollo de bater\u00edas y los pol\u00edmeros. Este tipo de an\u00e1lisis examina el comportamiento del flujo y las propiedades mec\u00e1nicas de los materiales en polvo, que difieren fundamentalmente de los de los l\u00edquidos<\/p>\n","protected":false},"author":1774,"featured_media":2826,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[132],"tags":[],"division":[],"class_list":{"0":"post-2825","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-materiales","8":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Principios y capacidades de la reolog\u00eda de polvos - Ciencia Acelerada<\/title>\n<meta name=\"description\" content=\"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Principios y capacidades de la reolog\u00eda de polvos\" \/>\n<meta property=\"og:description\" content=\"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/\" \/>\n<meta property=\"og:site_name\" content=\"Ciencia Acelerada\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-21T17:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1877\" \/>\n\t<meta property=\"og:image:height\" content=\"503\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Aline Monserrat Mayorga\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisherla\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Aline Monserrat Mayorga\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/\"},\"author\":{\"name\":\"Aline Monserrat Mayorga\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/2a5627931cec71c38a016d2f23a352a3\"},\"headline\":\"Principios y capacidades de la reolog\u00eda de polvos\",\"datePublished\":\"2025-10-21T17:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/\"},\"wordCount\":1747,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/10\\\/Captura-de-pantalla-2025-10-14-173059.png\",\"articleSection\":[\"Materiales Avanzados\"],\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/\",\"name\":\"Principios y capacidades de la reolog\u00eda de polvos - Ciencia Acelerada\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/10\\\/Captura-de-pantalla-2025-10-14-173059.png\",\"datePublished\":\"2025-10-21T17:00:00+00:00\",\"description\":\"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#breadcrumb\"},\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/10\\\/Captura-de-pantalla-2025-10-14-173059.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/10\\\/Captura-de-pantalla-2025-10-14-173059.png\",\"width\":1877,\"height\":503},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/cienciaacelerada\\\/materiales\\\/principios-y-capacidades-de-la-reologia-de-polvos\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Principios y capacidades de la reolog\u00eda de polvos\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"name\":\"Ciencia Acelerada\",\"description\":\"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.\",\"publisher\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-MX\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#organization\",\"name\":\"Thermo Fisher Scientific\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/wp-content\\\/uploads\\\/sites\\\/17\\\/2025\\\/07\\\/Thermo_Fisher_Scientific_logo.svg_.png\",\"width\":1024,\"height\":231,\"caption\":\"Thermo Fisher Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ThermoFisherLatinAmerica\",\"https:\\\/\\\/x.com\\\/thermofisherla\",\"https:\\\/\\\/www.instagram.com\\\/thermofisherscientific\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/thermo-fisher-scientific\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCfUs2fCDhx07fkszsJ0jOcA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/cienciaacelerada\\\/#\\\/schema\\\/person\\\/2a5627931cec71c38a016d2f23a352a3\",\"name\":\"Aline Monserrat Mayorga\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g\",\"caption\":\"Aline Monserrat Mayorga\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/alinemonserrat-mayorgathermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Principios y capacidades de la reolog\u00eda de polvos - Ciencia Acelerada","description":"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/","og_locale":"es_MX","og_type":"article","og_title":"Principios y capacidades de la reolog\u00eda de polvos","og_description":"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.","og_url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/","og_site_name":"Ciencia Acelerada","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","article_published_time":"2025-10-21T17:00:00+00:00","og_image":[{"width":1877,"height":503,"url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","type":"image\/png"}],"author":"Aline Monserrat Mayorga","twitter_card":"summary_large_image","twitter_creator":"@thermofisherla","twitter_site":"@thermofisherla","twitter_misc":{"Escrito por":"Aline Monserrat Mayorga","Tiempo de lectura":"8 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/"},"author":{"name":"Aline Monserrat Mayorga","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/2a5627931cec71c38a016d2f23a352a3"},"headline":"Principios y capacidades de la reolog\u00eda de polvos","datePublished":"2025-10-21T17:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/"},"wordCount":1747,"commentCount":0,"publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","articleSection":["Materiales Avanzados"],"inLanguage":"es-MX","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/","url":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/","name":"Principios y capacidades de la reolog\u00eda de polvos - Ciencia Acelerada","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","datePublished":"2025-10-21T17:00:00+00:00","description":"Comprender el flujo de los polvos es vital para la calidad. Exploramos los principios de la reolog\u00eda de polvos y las t\u00e9cnicas anal\u00edticas avanzadas que definen las propiedades mec\u00e1nicas de materiales en diversas industrias.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#breadcrumb"},"inLanguage":"es-MX","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/"]}]},{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","width":1877,"height":503},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/materiales\/principios-y-capacidades-de-la-reologia-de-polvos\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/"},{"@type":"ListItem","position":2,"name":"Principios y capacidades de la reolog\u00eda de polvos"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#website","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","name":"Ciencia Acelerada","description":"Donde los cient\u00edficos con visi\u00f3n de futuro, los educadores y los profesionales de seguridad y calidad vienen a compartir y descubrir informaci\u00f3n que hace del mundo un lugar m\u00e1s saludable, limpio y seguro para vivir.","publisher":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-MX"},{"@type":"Organization","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#organization","name":"Thermo Fisher Scientific","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/","logo":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/","url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/07\/Thermo_Fisher_Scientific_logo.svg_.png","width":1024,"height":231,"caption":"Thermo Fisher Scientific"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ThermoFisherLatinAmerica","https:\/\/x.com\/thermofisherla","https:\/\/www.instagram.com\/thermofisherscientific\/","https:\/\/www.linkedin.com\/company\/thermo-fisher-scientific\/","https:\/\/www.youtube.com\/channel\/UCfUs2fCDhx07fkszsJ0jOcA"]},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/#\/schema\/person\/2a5627931cec71c38a016d2f23a352a3","name":"Aline Monserrat Mayorga","image":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/secure.gravatar.com\/avatar\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/48cdb163bbf23ce7fc2ed192e436d4dbced0244374e5617d566367cdd8f0fa3e?s=96&d=mm&r=g","caption":"Aline Monserrat Mayorga"},"url":"https:\/\/admin.acceleratingscience.com\/author\/alinemonserrat-mayorgathermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":132,"label":"Materiales Avanzados"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059-1024x274.png",760,203,true],"author_info":{"display_name":"Aline Monserrat Mayorga","author_link":"https:\/\/admin.acceleratingscience.com\/author\/alinemonserrat-mayorgathermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":132,"name":"Materiales Avanzados","slug":"materiales","term_group":0,"term_taxonomy_id":132,"taxonomy":"category","description":"","parent":0,"count":78,"filter":"raw","meta":[],"cat_ID":132,"category_count":78,"category_description":"","cat_name":"Materiales Avanzados","category_nicename":"materiales","category_parent":0}],"tag_info":false,"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/cienciaacelerada\/wp-content\/uploads\/sites\/17\/2025\/10\/Captura-de-pantalla-2025-10-14-173059.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/users\/1774"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/comments?post=2825"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/posts\/2825\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media\/2826"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/media?parent=2825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/categories?post=2825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/tags?post=2825"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/cienciaacelerada\/wp-json\/wp\/v2\/division?post=2825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}