{"id":2328,"date":"2022-04-20T12:59:05","date_gmt":"2022-04-20T12:59:05","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/connectedlab\/?p=2328"},"modified":"2025-01-02T11:59:32","modified_gmt":"2025-01-02T11:59:32","slug":"using-machine-learning-techniques-in-wine-quality-testing","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/","title":{"rendered":"Using Machine Learning Techniques in Wine Quality Testing"},"content":{"rendered":"<p>The <a href=\"https:\/\/www.thermofisher.com\/blog\/connectedlab\/machine-learning-to-increase-lab-efficiency\/\" target=\"_blank\" rel=\"noopener\">Profiling capability<\/a> from <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/digital-solutions\/lab-informatics\/lab-information-management-systems-lims\/solutions\/samplemanager\/latest-version.html\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 SampleManager\u2122 LIMS software<\/a> provides an innovative way for laboratories to predict test results using historical data and novel machine learning (ML)-based techniques.<\/p>\n<p>Anticipating the result of a test without conducting it has several benefits for a lab:<\/p>\n<ul>\n<li>Identify and eliminate the need to perform redundant tests.<\/li>\n<li>Reduce the number of samples tested.<\/li>\n<li>Save money by not using expensive reagents and consumables.<\/li>\n<li>Generate a prediction to all eligible samples without any extra cost or time.<\/li>\n<li>Take actions by anticipating the result of the test.<\/li>\n<li>Fail samples early that would not go on to pass the test.<\/li>\n<\/ul>\n<p>The Profiling capability of the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/digital-solutions\/lab-informatics\/data-analytics-solution.html?ce=E.21CMD.DS107.38781.01&amp;cid=E.21CMD.DS107.38781.01&amp;iq=IQLAAKGACZFZZZMZZZ\" target=\"_blank\" rel=\"noopener\">Data Analytics Solutions<\/a>\u00a0has many potential applications.\u00a0 For example, a food and beverage company might apply the Profiling capability to enable supervised learning in the food production process. In this case, SampleManager LIMS would use historical data to gain an understanding of the critical variables that determine whether a product is safe for consumers. This holistic approach considers not only the values of the individual critical variables themselves, but also the relationships between them. If a sample were to be flagged as failing, the system would alert stakeholders in advance to issue adjustments or investigations to avoid any risk to finished products.<\/p>\n<p>Noticing early that a product will fail one or more tests on the production line is vital to avoid spending resources on further testing and to take corrective actions to a product to avoid failing in the future.<\/p>\n<p>The Profiling capability also gives the laboratory a powerful tool to identify the tests that are more relevant based on their predictive power of an eventual pass or fail of a specific test of interest. This information will help the laboratory modify its production line to start with the more relevant tests, avoid executing a test and reduce its operational costs.<\/p>\n<div id=\"attachment_2339\" style=\"width: 810px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2339\" class=\"wp-image-2339 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg\" alt=\"Using machine learning techniques to predict wine quality\" width=\"800\" height=\"550\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg 800w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized-300x206.jpg 300w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized-768x528.jpg 768w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized-96x65.jpg 96w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><p id=\"caption-attachment-2339\" class=\"wp-caption-text\">Machine learning applications in wine quality testing.<\/p><\/div>\n<h2>Profiling capability: A wine quality use case<\/h2>\n<p>To understand the benefit of the Profiling capability, consider its application in a winery laboratory. A wine production facility conducts various tests on wine samples. The tests evaluate pH, alcohol, density, residual sugars, and others. After performing the full battery of standard tests, the quality control team executes a time consuming and expensive \u201cQuality Test\u201d that classifies a wine as high or low quality. High quality wines are packed and sold to final customers, while low quality wines are reprocessed and tested again to assure a high-quality product. Wines that fail to pass the second quality control will be sold at a lower cost to a different customer.<\/p>\n<h2>Early identification of wines for reprocessing reduces costs<\/h2>\n<p>As the final \u201cQuality Test\u201d is expensive and time consuming, wine testing laboratories want to predict the outcome of this test in advance. Knowing which samples are likely to pass the \u201cQuality Test\u201d would help accelerate the process and save resources by avoiding the final test for products that are not likely to pass. The Profiling capability can make such predictions by analyzing complex relationships between previous tests done to the wine such as pH, alcohol, residual sugars, and others.<\/p>\n<p>With this in mind, a wine laboratory could apply the <a href=\"https:\/\/www.thermofisher.com\/blog\/connectedlab\/enhancing-the-scientific-lab-experience-part-2-the-data-centric-environment\/\">Profiling capability<\/a> to the wine samples and evaluate its results to consider using the model as a predictor for the final test.<\/p>\n<div id=\"attachment_2331\" style=\"width: 1280px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2331\" class=\"wp-image-2331 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_results_evaluation.png\" alt=\"Prediction of the \u201cQuality Test\u201d using all previous tests in the production line.\" width=\"1270\" height=\"520\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_results_evaluation.png 1270w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_results_evaluation-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_results_evaluation-1024x419.png 1024w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_results_evaluation-768x314.png 768w\" sizes=\"auto, (max-width: 1270px) 100vw, 1270px\" \/><p id=\"caption-attachment-2331\" class=\"wp-caption-text\">Prediction of the \u201cQuality Test\u201d using all previous tests in the production line.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>In this example, the laboratory would notice the algorithm performance meets their needs and therefore could be used to predict the results of the \u201cQuality Test.\u201d In case there is a high probability of failure, further testing would be stopped, and the wine would be sent to reprocessing immediately.<\/p>\n<div id=\"attachment_2332\" style=\"width: 539px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2332\" class=\"wp-image-2332 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_new_workflow.png\" alt=\"New workflow using the Profiling capability.\" width=\"529\" height=\"616\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_new_workflow.png 529w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_new_workflow-258x300.png 258w\" sizes=\"auto, (max-width: 529px) 100vw, 529px\" \/><p id=\"caption-attachment-2332\" class=\"wp-caption-text\">New workflow using the Profiling capability.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Optimizing the production line to fail early<\/h2>\n<p>The order of the tests in a production line is normally defined by different business characteristics, such as stage of the product, time reduction, equipment optimization, the frequency of failing a specific test, physical limitations, and others. On top of the traditional variables, SampleManager software uses machine learning to anticipate the future outcomes of tests that will help the production engineers to optimize even further the production line.<\/p>\n<p>In a wine production facility, the result of the \u201cQuality Test\u201d is of utmost importance. The laboratory has great flexibility and control over the testing process, so they could use the Profiling capability to redefine the order of the standard tests conducted to a wine sample.<\/p>\n<p>First, they could calculate the model performance for each of the individual tests they perform.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"311\">\n<p><div id=\"attachment_2329\" style=\"width: 453px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2329\" class=\" wp-image-2329\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_ph_test-300x123.png\" alt=\"pH test for wine quality\" width=\"443\" height=\"182\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_ph_test-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_ph_test-1024x419.png 1024w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_ph_test-768x314.png 768w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_ph_test.png 1270w\" sizes=\"auto, (max-width: 443px) 100vw, 443px\" \/><p id=\"caption-attachment-2329\" class=\"wp-caption-text\">Evaluating the predictive power of the pH test.<\/p><\/div><\/td>\n<td width=\"313\">\n<p><div id=\"attachment_2330\" style=\"width: 449px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2330\" class=\" wp-image-2330\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_alcohol_test-300x123.png\" alt=\"Alcohol test for wine quality\" width=\"439\" height=\"180\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_alcohol_test-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_alcohol_test-1024x419.png 1024w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_alcohol_test-768x314.png 768w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_alcohol_test.png 1270w\" sizes=\"auto, (max-width: 439px) 100vw, 439px\" \/><p id=\"caption-attachment-2330\" class=\"wp-caption-text\">Evaluating the predictive power of the alcohol test.<\/p><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>After trying all the tests individually, the laboratory would see that some tests (such as pH) have an extremely low predictive power of the final \u201cQuality Test,\u201d but there are other tests (like \u201calcohol\u201d) give more information. They would notice that using just one test as a predictor for the \u201cQuality Test\u201d was not enough, as the metrics (sensitivity and specificity) of the model are not sufficient for their requirements.<\/p>\n<p>Secondly, the laboratory could experiment with a set of tests to evaluate their predictive power. In this example, the lab\u00a0 concluded that grouping various tests in three stages could provide valuable information to make the prediction. With such insight, the laboratory modified its standard testing in a three staged workflow:<\/p>\n<ul>\n<li>Stage 1: conduct alcohol, density, and chlorides. Predict the quality of the wine; if it passes, continue to Stage 2 otherwise fail early.<\/li>\n<li>Stage 2: Sum volatile acidity, residual sugar, sulphates, total sulfur dioxide and citric acid to the tests performed in Stage 1. Predict the quality of the wine; if it passes, continue to Stage 3 otherwise fail early.<\/li>\n<li>Stage 3: Finalize the rest of the tests and predict the quality of the wine. If it passes, continue to test the \u201cQuality test\u201d otherwise fail early.<\/li>\n<\/ul>\n<div id=\"attachment_2333\" style=\"width: 460px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2333\" class=\"wp-image-2333 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_fail_early.png\" alt=\"Processes optimized to fail early using the Profiling Capability.\" width=\"450\" height=\"722\" srcset=\"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_fail_early.png 450w, https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/profiling_wine_test_fail_early-187x300.png 187w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><p id=\"caption-attachment-2333\" class=\"wp-caption-text\">Processes optimized to fail early using the Profiling capability.<\/p><\/div>\n<p>&nbsp;<\/p>\n<h2>Profiling improves production efficiency and eliminates unnecessary testing<\/h2>\n<p>The Profiling capability of the Data Analytics Solutions has many potential applications. In wine quality testing, predicting the result of the \u201cQuality test\u201d at various stages of the production line using the Profiling capability could help a laboratory optimize its testing process by reducing the need of unnecessary testing and its associated resources.<\/p>\n<p>To learn more about the Profiling capabilities available in SampleManager LIMS software, visit our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/digital-solutions\/lab-informatics\/data-analytics-solution.html?ce=E.21CMD.DS107.38781.01&amp;cid=E.21CMD.DS107.38781.01&amp;iq=IQLAAKGACZFZZZMZZZ\" target=\"_blank\" rel=\"noopener\">Data Analytics Solutions.<\/a> website.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Profiling capability from Thermo Scientific\u2122 SampleManager\u2122 LIMS software provides an innovative way for laboratories to predict test results using historical data and novel machine learning (ML)-based techniques. Anticipating the result of a test without conducting it has several benefits for a lab: Identify and eliminate the need to perform redundant tests. Reduce the number<\/p>\n","protected":false},"author":1652,"featured_media":2339,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[207,89],"tags":[589,119,1042,862,499,590,617,861],"division":[],"class_list":["post-2328","post","type-post","status-publish","format-standard","has-post-thumbnail","category-food-science","category-technology","tag-connected-lab","tag-data-analysis-and-visualization","tag-data-analytics","tag-data-science","tag-lab-of-the-future","tag-machine-learning","tag-samplemanager-lims","tag-samplemanager-lims-software","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Using Machine Learning Techniques in Wine Quality Testing<\/title>\n<meta name=\"description\" content=\"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Using Machine Learning Techniques in Wine Quality Testing\" \/>\n<meta property=\"og:description\" content=\"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"The Connected Lab\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-20T12:59:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-02T11:59:32+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Dario Rodriguez\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dario Rodriguez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/\"},\"author\":{\"name\":\"Dario Rodriguez\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/#\\\/schema\\\/person\\\/48977d7c36a5359f500b526bf0b87539\"},\"headline\":\"Using Machine Learning Techniques in Wine Quality Testing\",\"datePublished\":\"2022-04-20T12:59:05+00:00\",\"dateModified\":\"2025-01-02T11:59:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/\"},\"wordCount\":1114,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/wp-content\\\/uploads\\\/sites\\\/14\\\/2022\\\/04\\\/wine_quality_blog_resized.jpg\",\"keywords\":[\"connected lab\",\"Data Analysis and Visualization\",\"data analytics\",\"data science\",\"Lab of the future\",\"Machine learning\",\"SampleManager LIMS\",\"SampleManager LIMS software\"],\"articleSection\":[\"Food Science\",\"Technology\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/\",\"name\":\"Using Machine Learning Techniques in Wine Quality Testing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/wp-content\\\/uploads\\\/sites\\\/14\\\/2022\\\/04\\\/wine_quality_blog_resized.jpg\",\"datePublished\":\"2022-04-20T12:59:05+00:00\",\"dateModified\":\"2025-01-02T11:59:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/#\\\/schema\\\/person\\\/48977d7c36a5359f500b526bf0b87539\"},\"description\":\"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/wp-content\\\/uploads\\\/sites\\\/14\\\/2022\\\/04\\\/wine_quality_blog_resized.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/wp-content\\\/uploads\\\/sites\\\/14\\\/2022\\\/04\\\/wine_quality_blog_resized.jpg\",\"width\":800,\"height\":550,\"caption\":\"Using machine learning techniques to predict wine quality\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/connectedlab\\\/using-machine-learning-techniques-in-wine-quality-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Using Machine Learning Techniques in Wine Quality Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/\",\"name\":\"The Connected Lab\",\"description\":\"Making the digital transformation of the lab meaningful, relatable and accessible for scientists and researchers across all industries and fields of study\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/connectedlab\\\/#\\\/schema\\\/person\\\/48977d7c36a5359f500b526bf0b87539\",\"name\":\"Dario Rodriguez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g\",\"caption\":\"Dario Rodriguez\"},\"description\":\"Dario Rodriguez is a Data Scientist with the Data Analytics and Visualization team at Thermo Fisher Scientific.\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/dariorodriguez\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Using Machine Learning Techniques in Wine Quality Testing","description":"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/","og_locale":"en_US","og_type":"article","og_title":"Using Machine Learning Techniques in Wine Quality Testing","og_description":"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.","og_url":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/","og_site_name":"The Connected Lab","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-04-20T12:59:05+00:00","article_modified_time":"2025-01-02T11:59:32+00:00","og_image":[{"width":800,"height":550,"url":"http:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","type":"image\/jpeg"}],"author":"Dario Rodriguez","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Dario Rodriguez","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/"},"author":{"name":"Dario Rodriguez","@id":"https:\/\/admin.acceleratingscience.com\/connectedlab\/#\/schema\/person\/48977d7c36a5359f500b526bf0b87539"},"headline":"Using Machine Learning Techniques in Wine Quality Testing","datePublished":"2022-04-20T12:59:05+00:00","dateModified":"2025-01-02T11:59:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/"},"wordCount":1114,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","keywords":["connected lab","Data Analysis and Visualization","data analytics","data science","Lab of the future","Machine learning","SampleManager LIMS","SampleManager LIMS software"],"articleSection":["Food Science","Technology"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/","url":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/","name":"Using Machine Learning Techniques in Wine Quality Testing","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/connectedlab\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","datePublished":"2022-04-20T12:59:05+00:00","dateModified":"2025-01-02T11:59:32+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/connectedlab\/#\/schema\/person\/48977d7c36a5359f500b526bf0b87539"},"description":"Read how machine learning techniques can help wine producers better predict which batches are likely to pass final quality testing.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","width":800,"height":550,"caption":"Using machine learning techniques to predict wine quality"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/using-machine-learning-techniques-in-wine-quality-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/connectedlab\/"},{"@type":"ListItem","position":2,"name":"Using Machine Learning Techniques in Wine Quality Testing"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/connectedlab\/#website","url":"https:\/\/admin.acceleratingscience.com\/connectedlab\/","name":"The Connected Lab","description":"Making the digital transformation of the lab meaningful, relatable and accessible for scientists and researchers across all industries and fields of study","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/connectedlab\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/connectedlab\/#\/schema\/person\/48977d7c36a5359f500b526bf0b87539","name":"Dario Rodriguez","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d11a20f58e70ac55186f4e7549c242b795ffa7aa622f4275bbb98bc2f56dd13b?s=96&d=mm&r=g","caption":"Dario Rodriguez"},"description":"Dario Rodriguez is a Data Scientist with the Data Analytics and Visualization team at Thermo Fisher Scientific.","url":"https:\/\/admin.acceleratingscience.com\/author\/dariorodriguez\/"}]}},"taxonomy_info":{"category":[{"value":207,"label":"Food Science"},{"value":89,"label":"Technology"}],"post_tag":[{"value":589,"label":"connected lab"},{"value":119,"label":"Data Analysis and Visualization"},{"value":1042,"label":"data analytics"},{"value":862,"label":"data science"},{"value":499,"label":"Lab of the future"},{"value":590,"label":"Machine learning"},{"value":617,"label":"SampleManager LIMS"},{"value":861,"label":"SampleManager LIMS software"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg",760,523,false],"author_info":{"display_name":"Dario Rodriguez","author_link":"https:\/\/admin.acceleratingscience.com\/author\/dariorodriguez\/"},"comment_info":0,"category_info":[{"term_id":207,"name":"Food Science","slug":"food-science","term_group":0,"term_taxonomy_id":207,"taxonomy":"category","description":"","parent":0,"count":10,"filter":"raw","meta":[],"cat_ID":207,"category_count":10,"category_description":"","cat_name":"Food Science","category_nicename":"food-science","category_parent":0},{"term_id":89,"name":"Technology","slug":"technology","term_group":0,"term_taxonomy_id":89,"taxonomy":"category","description":"","parent":0,"count":155,"filter":"raw","meta":[],"cat_ID":89,"category_count":155,"category_description":"","cat_name":"Technology","category_nicename":"technology","category_parent":0}],"tag_info":[{"term_id":589,"name":"connected lab","slug":"connected-lab","term_group":0,"term_taxonomy_id":589,"taxonomy":"post_tag","description":"","parent":0,"count":42,"filter":"raw","meta":[]},{"term_id":119,"name":"Data Analysis and Visualization","slug":"data-analysis-and-visualization","term_group":0,"term_taxonomy_id":119,"taxonomy":"post_tag","description":"","parent":0,"count":14,"filter":"raw","meta":[]},{"term_id":1042,"name":"data analytics","slug":"data-analytics","term_group":0,"term_taxonomy_id":1042,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":862,"name":"data science","slug":"data-science","term_group":0,"term_taxonomy_id":862,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]},{"term_id":499,"name":"Lab of the future","slug":"lab-of-the-future","term_group":0,"term_taxonomy_id":499,"taxonomy":"post_tag","description":"","parent":0,"count":45,"filter":"raw","meta":[]},{"term_id":590,"name":"Machine learning","slug":"machine-learning","term_group":0,"term_taxonomy_id":590,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":617,"name":"SampleManager LIMS","slug":"samplemanager-lims","term_group":0,"term_taxonomy_id":617,"taxonomy":"post_tag","description":"","parent":0,"count":20,"filter":"raw","meta":[]},{"term_id":861,"name":"SampleManager LIMS software","slug":"samplemanager-lims-software","term_group":0,"term_taxonomy_id":861,"taxonomy":"post_tag","description":"","parent":0,"count":40,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/connectedlab\/wp-content\/uploads\/sites\/14\/2022\/04\/wine_quality_blog_resized.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/posts\/2328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/users\/1652"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/comments?post=2328"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/posts\/2328\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/media\/2339"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/media?parent=2328"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/categories?post=2328"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/tags?post=2328"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/connectedlab\/wp-json\/wp\/v2\/division?post=2328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}