{"id":5432,"date":"2015-08-13T04:00:44","date_gmt":"2015-08-13T08:00:44","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=5432"},"modified":"2015-08-13T04:00:44","modified_gmt":"2015-08-13T08:00:44","slug":"modeling-contamination-in-poultry-meat","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/","title":{"rendered":"Modeling Contamination in Poultry Meat"},"content":{"rendered":"<p><span><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg\" style=\"float: right\" alt=\"Raw roasting chicken, isolated on a white background\" title=\"Raw roasting chicken, isolated on a white background\" width=\"330\" height=\"220\" \/>Raw poultry meat is easily contaminated with harmful foodborne pathogens such as <\/span><a href=\"http:\/\/admin.acceleratingscience.com\/food\/fact-sheet-on-salmonella\/\"><em>Salmonella<\/em><\/a><span> and <\/span><a href=\"http:\/\/admin.acceleratingscience.com\/food\/fact-sheet-on-listeria\/\"><em>Listeria monocytogenes<\/em><\/a><span> with contamination possible at multiple stages during the life of the meat. Seeking to better understand when contamination happens, and to what extent, Lerasle<em> et al<\/em>. developed a probabilistic model focusing on contamination levels of <\/span><em>Salmonella<\/em><span> and <\/span><span><em>Listeria monocytogen<\/em>es<\/span><span> in poultry meat before and after a high pressure (HP) treatment.<sup>1<\/sup><\/span><\/p>\n<p><span>For their investigation, the team developed a model &nbsp;based on four crucial steps in the shelf-life of poultry:<\/span><\/p>\n<p><span>1. Reception of raw meat materials, mincing and mixing meat.<\/span><\/p>\n<p><span>2. Partitioning and packaging into 200g modified atmosphere packs.<\/span><\/p>\n<p><span>3. High pressure treatment of the meat.<\/span><\/p>\n<p><span>4. Storage in chilled conditions until the end of the shelf-life. <\/span><\/p>\n<p>Since contamination can occur during the very early stages of meat processing, the team collected data from the primary meat processing plants in France to get initial contamination levels of <em>Salmonella<\/em> and <em>Listeria monocytogenes<\/em>. This data made up steps one and two. Step three was the main focus for this investigation. Step four came from existing literature and data models.<\/p>\n<p><span>The meat used in this study came from turkey meat (79%), pork fat (11%), spices (less than 0.1%) and water (10%). While at the factory, workers minced and mixed meats to form a 100kg mixture and then stored it at 4 &deg;C prior to partitioning and packaging meats. Researchers surveyed 25g meat samples for <\/span><em>Salmonella<\/em><span> and <\/span><em>L.&nbsp;monocytogenes<\/em><span> using cultures on<a href=\"http:\/\/www.thermoscientific.com\/en\/product\/xld-agar.html\" target=\"_blank\"><span style=\"color: #333333\"> Xylose-Lysine-Desoxycholate<\/span> <\/a>(XLD) agar and <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/oxoid-brilliance-listeria-agar-base.html\" target=\"_blank\">Oxoid <em>Brilliance<\/em><span style=\"color: #000000\"> Listeria Agar <\/span><\/a>(Thermo Scientific), respectively. They found that the level of contamination of the minced meat, before cooking, was estimated to be low. They determined levels were in the 99th percentile of the distribution and equal to &minus;2.3 log cfu\/g for <\/span><em>Salmonella<\/em><span> and 0.5 log cfu\/g for <\/span><em>L. monocytogenes.<\/em><\/p>\n<p><span>To study the effects of HP treatment and potassium lactate on these pathogens, the team evaluated samples using standard factory pressure conditions, including pressure at 200, 350 and 500 MPa, holding time for 2, 8 and 14 <span style=\"color: #000000\">minutes<\/span> and potassium lactate concentrations of 0 or 1.8% w\/w. They cultured samples using <span style=\"color: #000000\">Oxoid <\/span>TSYEA plates&nbsp;(Thermo Scientific). <\/span><span><em>Salmonella<\/em> <\/span><span>was unable to grow in the presence of lactate.<\/span><\/p>\n<p><span>The following table helps summarize the calculated probability of contamination in raw poultry.<\/span><\/p>\n<table>\n<colgroup>\n<col width=\"114\" \/>\n<col width=\"103\" \/>\n<col width=\"72\" \/>\n<col width=\"72\" \/>\n<col width=\"87\" \/>\n<col width=\"72\" \/>\n<col width=\"72\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td>&nbsp;<\/td>\n<td>\n<p><span>L. monocytogenes<\/span><\/p>\n<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<td>\n<p><span>Salmonella<\/span><\/p>\n<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Steps<\/span><\/p>\n<\/td>\n<td>\n<p><span>Prevalence<\/span><\/p>\n<\/td>\n<td>\n<p><span>P(X &le; 1 cfu\/g)<\/span><\/p>\n<\/td>\n<td>\n<p><span>P(X &le; 10 cfu\/g)<\/span><\/p>\n<\/td>\n<td>\n<p><span>Prevalence<\/span><\/p>\n<\/td>\n<td>\n<p><span>P(X &le; 1 cfu\/g)<\/span><\/p>\n<\/td>\n<td>\n<p><span>P(X &le; 10 cfu\/g)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Mixing into 100-kg meat<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Partitioning into 200 g<\/span><\/p>\n<\/td>\n<td>\n<p><span>7.60%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>62%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>High pressure treatment<\/span><\/p>\n<\/td>\n<td>\n<p><span>7.10%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>4.14%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Storage<\/span><\/p>\n<\/td>\n<td>\n<p><span>7.10%<\/span><\/p>\n<\/td>\n<td>\n<p><span>93%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>4.14%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<td>\n<p><span>100%<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span>After the HP pressure treatment, the prevalence &nbsp;decreased further down to a low level (4.14% and 7.10%) for&nbsp;<\/span><span><em>Listeria monocytogenes<\/em> and <em>Salmonella<\/em><\/span><span>, respectively. The HP treatment did indeed reduce the microbial prevalence and contamination level; however, they found lactate only affected microbial growth during storage in chilled conditions until the end of the shelf-life.<\/span><\/p>\n<p><span>Summarizing the findings, the team recommends using HP treatment and lactate formulation before cooking poultry meats to decrease contamination. They also suggest future work should focus on stability in spoilage microorganisms after HP treatment, potassium lactate addition.<\/span><\/p>\n<p><strong>For more discussion on testing for food borne pathogens <a href=\"http:\/\/www.thermoscientific.com\/en\/community\/microbiology-testing.html\" target=\"_blank\">visit our Food and Beverage Community<\/a><\/strong><\/p>\n<p><strong>Reference<\/strong><\/p>\n<p><span><span>1. Lerasle M., et al. (2014) &ldquo;<a href=\"http:\/\/www.pubfacts.com\/detail\/25016206\/Assessment-of-Salmonella-and-Listeria-monocytogenes-level-in-ready-to-cook-poultry-meat:-effect-of-v\" target=\"_blank\">Assessment of Salmonella and Listeria monocytogenes level in ready-to-cook poultry meat: effect of various high pressure treatments and potassium lactate concentrations.<\/a>&rdquo; International Journal of Food Microbiology, 2014 Sep 1;186:( pp. 74-83). doi: 10.1016\/j.ijfoodmicro.2014.06.019. Epub 2014 Jun 27.<\/span><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Raw poultry meat is easily contaminated with harmful foodborne pathogens such as Salmonella and Listeria monocytogenes with contamination possible at multiple stages during the life of the meat. Seeking to better understand when contamination happens, and to what extent, Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes<\/p>\n","protected":false},"author":13,"featured_media":5431,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[3],"tags":[],"division":[],"class_list":["post-5432","post","type-post","status-publish","format-standard","has-post-thumbnail","category-microbiology-testing","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Modeling Contamination in Poultry meat<\/title>\n<meta name=\"description\" content=\"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modeling Contamination in Poultry Meat\" \/>\n<meta property=\"og:description\" content=\"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/\" \/>\n<meta property=\"og:site_name\" content=\"Examining Food\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-08-13T08:00:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Emily Humphreys\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Emily Humphreys\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/\"},\"author\":{\"name\":\"Emily Humphreys\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/#\\\/schema\\\/person\\\/f67f8c7c84f2ab8c1ac993b2d8f49e87\"},\"headline\":\"Modeling Contamination in Poultry Meat\",\"datePublished\":\"2015-08-13T08:00:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/\"},\"wordCount\":559,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2015\\\/08\\\/raw_roasting_chicken__isolated_on_a_white_background.jpg\",\"articleSection\":[\"Microbiology Testing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/\",\"name\":\"Modeling Contamination in Poultry meat\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2015\\\/08\\\/raw_roasting_chicken__isolated_on_a_white_background.jpg\",\"datePublished\":\"2015-08-13T08:00:44+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/#\\\/schema\\\/person\\\/f67f8c7c84f2ab8c1ac993b2d8f49e87\"},\"description\":\"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2015\\\/08\\\/raw_roasting_chicken__isolated_on_a_white_background.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2015\\\/08\\\/raw_roasting_chicken__isolated_on_a_white_background.jpg\",\"width\":1000,\"height\":667,\"caption\":\"Raw roasting chicken, isolated on a white background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/food\\\/modeling-contamination-in-poultry-meat\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Modeling Contamination in Poultry Meat\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/\",\"name\":\"Examining Food\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/food\\\/#\\\/schema\\\/person\\\/f67f8c7c84f2ab8c1ac993b2d8f49e87\",\"name\":\"Emily Humphreys\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g\",\"caption\":\"Emily Humphreys\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/emilyhumphreys\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Modeling Contamination in Poultry meat","description":"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/","og_locale":"en_US","og_type":"article","og_title":"Modeling Contamination in Poultry Meat","og_description":"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat","og_url":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/","og_site_name":"Examining Food","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-08-13T08:00:44+00:00","og_image":[{"width":1000,"height":667,"url":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","type":"image\/jpeg"}],"author":"Emily Humphreys","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Emily Humphreys","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/"},"author":{"name":"Emily Humphreys","@id":"https:\/\/admin.acceleratingscience.com\/food\/#\/schema\/person\/f67f8c7c84f2ab8c1ac993b2d8f49e87"},"headline":"Modeling Contamination in Poultry Meat","datePublished":"2015-08-13T08:00:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/"},"wordCount":559,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","articleSection":["Microbiology Testing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/","url":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/","name":"Modeling Contamination in Poultry meat","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/food\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","datePublished":"2015-08-13T08:00:44+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/food\/#\/schema\/person\/f67f8c7c84f2ab8c1ac993b2d8f49e87"},"description":"Lerasle et al. developed a probabilistic model focusing on contamination levels of Salmonella and Listeria monocytogenes in poultry meat","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","width":1000,"height":667,"caption":"Raw roasting chicken, isolated on a white background"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/food\/modeling-contamination-in-poultry-meat\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/food\/"},{"@type":"ListItem","position":2,"name":"Modeling Contamination in Poultry Meat"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/food\/#website","url":"https:\/\/admin.acceleratingscience.com\/food\/","name":"Examining Food","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/food\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/food\/#\/schema\/person\/f67f8c7c84f2ab8c1ac993b2d8f49e87","name":"Emily Humphreys","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/878cbec1206c605e58941f79404bd506da2c188f011046a339d0b069c1c97d0d?s=96&d=mm&r=g","caption":"Emily Humphreys"},"url":"https:\/\/admin.acceleratingscience.com\/author\/emilyhumphreys\/"}]}},"jetpack_publicize_connections":[],"taxonomy_info":{"category":[{"value":3,"label":"Microbiology Testing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg",760,507,false],"author_info":{"display_name":"Emily Humphreys","author_link":"https:\/\/admin.acceleratingscience.com\/author\/emilyhumphreys\/"},"comment_info":0,"category_info":[{"term_id":3,"name":"Microbiology Testing","slug":"microbiology-testing","term_group":0,"term_taxonomy_id":3,"taxonomy":"category","description":"","parent":0,"count":163,"filter":"raw","meta":[],"cat_ID":3,"category_count":163,"category_description":"","cat_name":"Microbiology Testing","category_nicename":"microbiology-testing","category_parent":0}],"tag_info":false,"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/food\/wp-content\/uploads\/sites\/5\/2015\/08\/raw_roasting_chicken__isolated_on_a_white_background.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/posts\/5432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/comments?post=5432"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/posts\/5432\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/media\/5431"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/media?parent=5432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/categories?post=5432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/tags?post=5432"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/food\/wp-json\/wp\/v2\/division?post=5432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}