{"id":10050,"date":"2021-09-22T14:25:29","date_gmt":"2021-09-22T05:25:29","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=10050"},"modified":"2025-04-01T16:22:13","modified_gmt":"2025-04-01T07:22:13","slug":"antibody_characterization_pca_bid_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/","title":{"rendered":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de"},"content":{"rendered":"<h2>\u591a\u80fd\u6027\u5e79\u7d30\u80de\u3068\u306f\uff1f<\/h2>\n<p>\u30d2\u30c8\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306f\u3001\u81ea\u5df1\u3092\u969b\u9650\u306a\u304f\u518d\u751f\u3057\u3001\u9069\u5207\u306a\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3044\u3066\u30d2\u30c8\u4f53\u5185\u306b\u5b58\u5728\u3059\u308b\u307b\u307c\u5168\u3066\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u3002PSC\u306f\u3001\u80da\u6027\u5e79\u7d30\u80de\uff08ESC\uff09\u3068\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC\uff09\u306e2\u7a2e\u985e\u304c\u4e00\u822c\u7684\u306b\u7814\u7a76\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u56f32.1\uff09\u3002\u30d2\u30c8ESC\u306f\u3001\u767a\u751f\u4e2d\u306e\u80da\u306e\u80da\u76e4\u80de\u671f\u306e\u5185\u90e8\u7d30\u80de\u584a\u304b\u3089\u5358\u96e2\u3055\u308c\u307e\u3059<sup>*1<\/sup> \u3002iPSC\u306f\u3001ESC\u3068\u540c\u7b49\u307e\u305f\u306f\u985e\u4f3c\u3059\u308b\u7d30\u80de\u3067\u3059\u304c\u3001\u6210\u4f53\u4f53\u7d30\u80de\u3092\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u3059\u308b\u305f\u3081\u306eOCT3\/4\u3001KLF4\u3001SOX2\u3001\u304a\u3088\u3073c-MYC\u306a\u3069\u306e\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u56e0\u5b50\u306e\u767a\u73fe\u3092\u7d4c\u3066\u751f\u6210\u3057\u307e\u3059<sup>*2,3<\/sup> \u3002iPSC\u306f\u3001\u60a3\u8005\u306e\u5e79\u7d30\u80de\u306e\u8a98\u5c0e\u3092\u7c21\u7d20\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u5e79\u7d30\u80de\u7814\u7a76\u306b\u9769\u547d\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001iPSC\u3092\u4f7f\u7528\u3057\u3066\u3001\u30b7\u30e3\u30fc\u30ec\u4e2d\u3067\u75be\u60a3\u7279\u7570\u7684\u306a\u7d30\u80de\u30bf\u30a4\u30d7\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/disease-modeling.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30e2\u30c7\u30eb<\/a>\u3092\u4f5c\u88fd\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u30e2\u30c7\u30eb\u306f\u3001\u75be\u60a3\u75c5\u614b\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u5b9a\u7fa9\u3059\u308b\u306e\u306b\u6709\u7528\u3067\u3001\u6cbb\u7642\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u540c\u5b9a\u3084\u5275\u85ac\u306b\u304a\u3044\u3066\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u6a5f\u80fd\u7684\u306a\u6210\u719f\u7d30\u80de\u306b\u5206\u5316\u3059\u308b\u3088\u3046\u65b9\u5411\u4ed8\u3051\u308b\u3053\u3068\u304c\u53ef\u80fd\u306aiPSC\u3092\u7121\u5236\u9650\u306b\u4f9b\u7d66\u3067\u304d\u308b\u3053\u3068\u306f\u3001\u7cd6\u5c3f\u75c5\u3001\u809d\u75be\u60a3\u3001\u304a\u3088\u3073\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u3084\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306a\u3069\u306e\u69d8\u3005\u306a\u75be\u60a3\u306b\u5bfe\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/clinical\/cell-gene-therapy\/cell-therapy\/cell-therapy-systems.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7d30\u80de\u7642\u6cd5<\/a>\u306e\u305f\u3081\u306e\u539f\u6750\u6599\u3068\u3057\u3066\u975e\u5e38\u306b\u6709\u671b\u8996\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10057\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-2.jpg\" alt=\"\" width=\"411\" height=\"510\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-2.jpg 411w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-2-242x300.jpg 242w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/><\/p>\n<h2>\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p>iPSC\u304a\u3088\u3073ESC\u3067\u306f\u3001\u672a\u5206\u5316\u5e79\u7d30\u80de\u72b6\u614b\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306bNanog\u304a\u3088\u3073OCT4\u306a\u3069\u306e\u30ad\u30fc\u8ee2\u5199\u56e0\u5b50\u306e\u767a\u73fe\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059<sup>*4<\/sup> \u3002\u3053\u308c\u3089\u306e\u8ee2\u5199\u56e0\u5b50\u306f\u3001\u7d30\u80de\u306e\u5206\u88c2\u3001\u5206\u5316\u3001\u304a\u3088\u3073\u767a\u9054\u306b\u91cd\u8981\u306a\u907a\u4f1d\u5b50\u3092\u8abf\u7bc0\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u8ee2\u5199\u56e0\u5b50\u306e\u4ed6\u306b\u3001TRA-1-60\u3001TRA-1-81\u3001SSEA3\u3001\u304a\u3088\u3073SSEA4\u306a\u3069\u306e\u7279\u5b9a\u306e\u4e00\u9023\u306e\u7d30\u80de\u8868\u9762\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u3001\u901a\u5e38\u3001PSC\u306b\u3088\u3063\u3066\u767a\u73fe\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30de\u30fc\u30ab\u30fc\u306e\u5b58\u5728\u306e\u691c\u51fa\u306f\u3001\u65b0\u305f\u306b\u8a98\u5c0e\u3055\u308c\u305fiPSC\u682a\uff08iPSC line\uff09\u304a\u3088\u3073ESC\u682a\uff08ES Cline\uff09\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3051\u308b\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\u306e1\u3064\u3067\u3059\u3002\u7279\u5b9a\u306e\u7d30\u80de\u306e\u67d3\u8272\u306f\u3001\u3053\u308c\u3089\u306e\u78ba\u7acb\u3055\u308c\u305f\u591a\u80fd\u6027\u30de\u30fc\u30ab\u30fc\u306b\u5bfe\u3059\u308b\u6297\u4f53\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u9054\u6210\u3067\u304d\u307e\u3059\uff08\u88682.1\uff09\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10051\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2.jpg\" alt=\"\" width=\"403\" height=\"955\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2.jpg 403w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-127x300.jpg 127w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><\/p>\n<h3>\u751f\u7d30\u80de\u306e\u514d\u75ab\u67d3\u8272<\/h3>\n<p>\u7d30\u80de\u8868\u9762\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u3001\u5168\u7d30\u80de\u306b\u8272\u7d20\u6a19\u8b58\u6297\u4f53\u3067\u8fc5\u901f\u306b\u67d3\u8272\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u653e\u5c04\u7dda\u7167\u5c04\u3057\u305f\u30de\u30a6\u30b9\u80ce\u4ed4\u7dda\u7dad\u82bd\u7d30\u80de\uff08MEF\uff09\u306e\u30d5\u30a3\u30fc\u30c0\u30fc\u5c64\u4e0a\u3067\u57f9\u990a\u3057\u305fiPSC\u30b3\u30ed\u30cb\u30fc\u4e0a\u306ePSC\u8868\u9762\u30de\u30fc\u30ab\u30fcTRA-1-60\u306e\u751f\u7d30\u80de\u514d\u75ab\u67d3\u8272\u306e\u4f8b\u3092\u56f32.2\u306b\u793a\u3057\u307e\u3059\u3002CD44\u306f\u3001MEF\u3092\u542b\u3080\u591a\u304f\u306e\u5206\u5316\u7d30\u80de\u3067\u767a\u73fe\u3055\u308c\u308b\u8868\u9762\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3059\u304c\u3001PSC\u3067\u306f\u767a\u73fe\u3057\u307e\u305b\u3093\u3002\u65b0\u305f\u306b\u8a98\u5c0e\u3057\u305fiPSC\u30b3\u30ed\u30cb\u30fc\u304c\u5b8c\u5168\u306b\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u3055\u308c\u3066\u3044\u308b\u304b\u306e\u78ba\u8a8d\u306b\u306f\u3001TRA-1-60\u306e\u30dd\u30b8\u30c6\u30a3\u30d6\u67d3\u8272\u3068CD44\u306e\u30cd\u30ac\u30c6\u30a3\u30d6\u67d3\u8272\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10052\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3.jpg\" alt=\"\" width=\"399\" height=\"463\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3.jpg 399w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-259x300.jpg 259w\" sizes=\"auto, (max-width: 399px) 100vw, 399px\" \/><\/p>\n<h3>\u56fa\u5b9a\u7d30\u80de\u306e\u514d\u75ab\u67d3\u8272<\/h3>\n<p>iPSC\u30af\u30ed\u30fc\u30f3\u306e\u54c1\u8cea\u306e\u4fe1\u983c\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u308f\u305a\u304b1\u3064\u304b2\u3064\u3067\u306a\u304f\u3001\u8907\u6570\u306ePSC\u30de\u30fc\u30ab\u30fc\u306e\u767a\u73fe\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002Oct4\u3001Nanog\u3001Lin28\u3001\u304a\u3088\u3073Sox2\u306a\u3069\u306e\u4e00\u90e8\u306e\u30de\u30fc\u30ab\u30fc\u306f\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3042\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u30de\u30fc\u30ab\u30fc\u306e\u67d3\u8272\u3092\u884c\u3046\u969b\u306f\u56fa\u5b9a\u304a\u3088\u3073\u900f\u904e\u51e6\u7406\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\uff08\u56f32.3\uff09\u3002\u3053\u308c\u3089\u306e\u30de\u30fc\u30ab\u30fc\u304a\u3088\u3073\u4ed6\u306ePSC\u30de\u30fc\u30ab\u30fc\u306b\u5bfe\u3059\u308b\u8272\u7d20\u6a19\u8b58\u4e00\u6b21\u6297\u4f53\u3092\u4f7f\u7528\u3059\u308b\u3068\uff08\u88682.1\uff09\u3001\u4e8c\u6b21\u6297\u4f53\u67d3\u8272\u5de5\u7a0b\u3092\u56de\u907f\u3067\u304d\u3001\u5b9f\u9a13\u306b\u304b\u304b\u308b\u6642\u9593\u3068\u30b3\u30b9\u30c8\u3092\u524a\u6e1b\u3057\u3001\u591a\u91cd\u67d3\u8272\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\uff08\u56f32.4\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10053\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4.jpg\" alt=\"\" width=\"398\" height=\"762\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4.jpg 398w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-157x300.jpg 157w\" sizes=\"auto, (max-width: 398px) 100vw, 398px\" \/><\/p>\n<h3>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc<\/h3>\n<p>\u4e0a\u8ff0\u306e\u67d3\u8272\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/cellular-imaging.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0<\/a>\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u5b9a\u6027\u7684\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc<\/a>\u306f\u30de\u30fc\u30ab\u30fc\u3092\u767a\u73fe\u3057\u305f\u7d30\u80de\u306e\u500b\u6570\u304a\u3088\u3073\u305d\u306e\u86cd\u5149\u5f37\u5ea6\u306e\u5b9a\u91cf\u7684\u6e2c\u5b9a\u3092\u63d0\u4f9b\u3057\u3001\u30de\u30fc\u30ab\u30fc\u306e\u3042\u3089\u3086\u308b\u30c0\u30a6\u30f3\u30ec\u30ae\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3001\u3042\u308b\u3044\u306f\u7d30\u80de\u96c6\u56e3\u306e\u4e0d\u5747\u4e00\u6027\u3092\u660e\u3089\u304b\u306b\u3057\u307e\u3059\u3002\u6700\u3082\u4e00\u822c\u7684\u306a\u306e\u306f\u3001SSEA4\u304a\u3088\u3073TRA-1-60\u306a\u3069\u306e\u8868\u9762\u30de\u30fc\u30ab\u30fc\u3092\u4f7f\u7528\u3059\u308b\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u3059\u304c\u3001\u56fa\u5b9a\u304a\u3088\u3073\u900f\u904e\u51e6\u7406\u3057\u305f\u7d30\u80de\u3092\u4f7f\u7528\u3057\u3066\u3001Nanog\u304a\u3088\u3073SOX2\u306a\u3069\u306e\u6838\u30de\u30fc\u30ab\u30fc\u3092\u4f7f\u7528\u3059\u308b\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\uff08\u56f32.5\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10054\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5.jpg\" alt=\"\" width=\"399\" height=\"502\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5.jpg 399w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-238x300.jpg 238w\" sizes=\"auto, (max-width: 399px) 100vw, 399px\" \/><br \/>\nPSC\u306e\u89e3\u6790\u304a\u3088\u3073\u81ea\u5df1\u8907\u88fd\u907a\u4f1d\u5b50\u7523\u7269\u306e\u5b58\u5728\u3084\u4f53\u7d30\u80de\u907a\u4f1d\u5b50\u7523\u7269\u306e\u4e0d\u5728\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306f\u91cd\u8981\u3067\u3059\u304c\u3001PSC\u682a\u306e\u6a5f\u80fd\u7684\u591a\u80fd\u6027\u306b\u3064\u3044\u3066\u306e\u78ba\u8a8d\u306b\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u306e\u4ed6\u306e\u91cd\u8981\u306a\u8a66\u9a13\u306b\u3001PSC\u306e\u4e09\u80da\u8449\uff08\u5916\u80da\u8449\u3001\u4e2d\u80da\u8449\u3001\u5185\u80da\u8449\uff09\u306e\u5404\u7d30\u80de\u3078\u306e\u5206\u5316\u80fd\u306e\u8a55\u4fa1\u304c\u3042\u308a\u307e\u3059\uff08\u56f32.6\uff09\u3002\u3053\u306e\u8a66\u9a13\u306f\u3001 in vitro \u304a\u3088\u3073 in vitro\u306e\u3044\u305a\u308c\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3088\u3063\u3066\u3082\u9054\u6210\u3067\u304d\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10055\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6.jpg\" alt=\"\" width=\"718\" height=\"463\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6.jpg 718w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-300x193.jpg 300w\" sizes=\"auto, (max-width: 718px) 100vw, 718px\" \/><\/p>\n<h3>\u30c6\u30e9\u30c8\u30fc\u30de\u5f62\u6210<\/h3>\n<p>\u30de\u30a6\u30b9PSC\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u56db\u500d\u4f53\u88dc\u5b8c\u6cd5\u3001\u30ad\u30e1\u30e9\u4f5c\u88fd\u3001\u304a\u3088\u3073\u751f\u6b96\u7cfb\u5217\u4f1d\u9054\u306a\u3069\u306e\u6570\u591a\u304f\u306e in vitro \u30a2\u30c3\u30bb\u30a4\u3092\u901a\u3057\u3066\u3001\u5206\u5316\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u30d2\u30c8\u7d30\u80de\u3067\u5b9f\u884c\u53ef\u80fd\u306a\u9078\u629e\u80a2\u3067\u306f\u306a\u3044\u305f\u3081\u3001\u4ee3\u308f\u308a\u306b\u30d2\u30c8PSC\u3092\u30de\u30a6\u30b9\u306b\u6ce8\u5165\u3057\u3001\u30c6\u30e9\u30c8\u30fc\u30de\u3092\u5f62\u6210\u3055\u305b\u3066\u3001\u4e09\u80da\u8449\u3078\u306e\u5206\u5316\u80fd\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u89e3\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002in vitro \u30a2\u30c3\u30bb\u30a4\u3067\u306f\u3001\u751f\u7406\u7684\u6761\u4ef6\u4e0b\u3067\u306e\u7d30\u80de\u306e\u5206\u5316\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u30c6\u30e9\u30c8\u30fc\u30de\u5f62\u6210\u306fPSC\u306e\u5206\u5316\u80fd\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u3053\u306e\u65b9\u6cd5\u306f\u975e\u5e38\u306b\u624b\u9593\u304c\u304b\u304b\u308a\u3001\u5b8c\u4e86\u307e\u30676\uff5e12\u9031\u9593\u3092\u8981\u3057\u3001\u52d5\u7269\u5b9f\u9a13\u306e\u8ca0\u62c5\u304c\u5927\u304d\u3044\u3053\u3068\u304b\u3089\u3001\u5e38\u306b\u5b9f\u65bd\u3055\u308c\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<h3>\u80da\u69d8\u4f53\uff08EB\uff09\u5f62\u6210<\/h3>\n<p>\u30c6\u30e9\u30c8\u30fc\u30de\u5f62\u6210\u306b\u4ee3\u308f\u308b\u3088\u308a\u4e00\u822c\u7684\u306a\u65b9\u6cd5\u306f\u3001EB\u5f62\u6210\u3068\u3044\u3046 in vitro \u30a2\u30c3\u30bb\u30a4\u3067\u30017\uff5e21\u65e5\u3067PSC\u304c\u4e09\u80da\u8449\u306b\u81ea\u767a\u7684\u306b\u5206\u5316\u3057\u307e\u3059\u3002\u5206\u5316\u306f\u975e\u751f\u7406\u7684\u6761\u4ef6\u4e0b\u3067\u751f\u3058\u307e\u3059\u304c\u3001EB\u5f62\u6210\u306f\u3088\u308a\u8fc5\u901f\u3067\u3001\u52b4\u529b\u304c\u5c11\u306a\u304f\u3001\u7c21\u5358\u306b\u89e3\u6790\u3067\u304d\u308b\u3068\u3044\u3046\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002EB\u306b\u304a\u3051\u308b\u5206\u5316\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u4e00\u822c\u7684\u306a\u30de\u30fc\u30ab\u30fc\u306b\u306f\u3001\u4e2d\u80da\u8449\u306e\u5e73\u6ed1\u7b4b\u30a2\u30af\u30c1\u30f3\uff08SMA\uff09\u3001\u5185\u80da\u8449\u306e\u521d\u671f\u809d\u7d30\u80de\u30de\u30fc\u30ab\u30fc\u306e\u03b1-\u30d5\u30a7\u30c8\u30d7\u30ed\u30c6\u30a4\u30f3\uff08AFP\uff09\u3001\u304a\u3088\u3073\u5916\u80da\u8449\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u30de\u30fc\u30ab\u30fc\u306e\u03b2-III\u30c1\u30e5\u30fc\u30d6\u30ea\u30f3\uff08TUBB3\uff09\u304c\u3042\u308a\u307e\u3059\uff08\u56f32.7\uff09\u3002\u4e00\u9023\u306e\u80da\u8449\u30de\u30fc\u30ab\u30fc\u3092\u4f7f\u7528\u3059\u308b\u514d\u75ab\u86cd\u5149\u306f\u3001\u3053\u308c\u3089\u306e\u5404\u30de\u30fc\u30ab\u30fc\u304c\u7279\u5b9a\u306e\u7d30\u80de\u7cfb\u7d71\u3067\u9078\u629e\u7684\u306b\u767a\u73fe\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u8996\u8a8d\u306b\u3088\u308b\u8ffd\u52a0\u306e\u6e2c\u5b9a\u3068\u3057\u3066\u6a5f\u80fd\u3057\u7d30\u80de\u5185\u5c40\u5728\u30d1\u30bf\u30fc\u30f3\u306e\u8b58\u5225\u3082\u793a\u3059\u70b9\u3067\u7279\u306b\u6709\u7528\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u6297TUBB3\u67d3\u8272\u306f\u3001\u7279\u5fb4\u7684\u306a\u30cb\u30e5\u30fc\u30ed\u30f3\u69d8\u7a81\u8d77\u3092\u6301\u3064\u7d30\u9577\u3044\u7d30\u80de\u306b\u5bfe\u3059\u308b\u4e00\u822c\u7684\u306b\u6700\u3082\u660e\u308b\u3044\u67d3\u8272\u3067\u3059\u3002SMA\u3092\u3057\u3063\u304b\u308a\u767a\u73fe\u3059\u308b\u7d30\u80de\u3067\u306f\u3001\u30a2\u30af\u30c1\u30f3\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u67d3\u8272\u306e\u7dda\u6a21\u69d8\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7d30\u80de\u306f\u3001\u5927\u304d\u3044\u5c64\u306e\u30b0\u30eb\u30fc\u30d7\u306b\u3088\u304f\u898b\u3089\u308c\u3001\u6642\u306b\u306f\u9c13\u72b6\u306e\u5f62\u72b6\u3092\u6301\u3064\u5927\u578b\u7d30\u80de\u3068\u3057\u3066\u5358\u96e2\u3055\u308c\u307e\u3059\u3002\u6297AFP\u67d3\u8272\u306f\u3001\u901a\u5e38\u3001\u305d\u308c\u305e\u308c\u6838\u306e\u5468\u56f2\u306b\u30ea\u30f3\u30b0\u72b6\u3068\u547c\u3070\u308c\u308b\u67d3\u8272\u30d1\u30bf\u30fc\u30f3\u3092\u6301\u3064\u7d30\u80de\u306e\u5bc6\u96c6\u3057\u305f\u30af\u30e9\u30b9\u30bf\u30fc\u3092\u540c\u5b9a\u3057\u307e\u3059\u3002\u4ed6\u306b\u3082\u591a\u304f\u306e\u30de\u30fc\u30ab\u30fc\u3001\u4f8b\u3048\u3070\u3001\u5185\u80da\u8449\u306ePDX1\u304a\u3088\u3073Sox17\u3001\u5916\u80da\u8449\u306eSox1\u304a\u3088\u3073Otx2\u3001\u306a\u3089\u3073\u306b\u4e2d\u80da\u8449\u306eNKX2.5\u304a\u3088\u3073PDGFRa\u304c\u5404\u80da\u8449\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u4f7f\u7528\u3055\u308c\u3066\u304d\u3066\u3044\u307e\u3059\uff08\u88682.2\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10056\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7.jpg\" alt=\"\" width=\"403\" height=\"934\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7.jpg 403w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-129x300.jpg 129w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><\/p>\n<p><strong>\u53c2\u8003\u6587\u732e\uff1a<\/strong><br \/>\n1. Thomson JA, Itskovitz-Eldor J, Shapiro SS et al. (1998) Embryonic stem cell lines derived from human blastocysts. Science 282(5391):1145\u20131147.<br \/>\n2. Takahashi K, Yamanaka S (2006) Induction of pluripotent stem cells from mouse embryonic and adult fibroblast cultures by defined factors. Cell 126(4):663\u2013676.<br \/>\n3. Yu J, Vodyanik MA, Smuga-Otto K et al. (2007) Induced pluripotent stem cell lines derived from human somatic cells. Science 318(5858):1917\u20131920.<br \/>\n4. Pan GJ, Thomson JA (2007) Nanog and transcriptional networks in embryonic stem cell pluripotency. Cell Res 17(1):42\u201349.<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u5e79\u7d30\u80de\u7814\u7a76\u7528\u6297\u4f53\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u672c\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u5e79\u7d30\u80de\u7814\u7a76\u306b\u95a2\u3059\u308b\u6df1\u3044\u77e5\u8b58\u306e\u7fd2\u5f97\u3001\u304a\u3088\u3073\u6700\u65b0\u306e\u7814\u7a76\u306b\u5f79\u7acb\u3064\u6297\u4f53\u95a2\u9023\u88fd\u54c1\u306e\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/en\/home\/global\/forms\/antibody-stem-cell-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u591a\u80fd\u6027\u5e79\u7d30\u80de\u3068\u306f\uff1f \u30d2\u30c8\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306f\u3001\u81ea\u5df1\u3092\u969b\u9650\u306a\u304f\u518d\u751f\u3057\u3001\u9069\u5207\u306a\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3044\u3066\u30d2\u30c8\u4f53\u5185\u306b\u5b58\u5728\u3059\u308b\u307b\u307c\u5168\u3066\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u3002PSC\u306f\u3001\u80da\u6027\u5e79\u7d30\u80de\uff08ESC\uff09\u3068\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC<\/p>\n","protected":false},"author":975,"featured_media":10097,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-10050","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\" \/>\n<meta property=\"og:description\" content=\"\u591a\u80fd\u6027\u5e79\u7d30\u80de\u3068\u306f\uff1f \u30d2\u30c8\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306f\u3001\u81ea\u5df1\u3092\u969b\u9650\u306a\u304f\u518d\u751f\u3057\u3001\u9069\u5207\u306a\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3044\u3066\u30d2\u30c8\u4f53\u5185\u306b\u5b58\u5728\u3059\u308b\u307b\u307c\u5168\u3066\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u3002PSC\u306f\u3001\u80da\u6027\u5e79\u7d30\u80de\uff08ESC\uff09\u3068\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-22T05:25:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T07:22:13+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1575\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\",\"datePublished\":\"2021-09-22T05:25:29+00:00\",\"dateModified\":\"2025-04-01T07:22:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/\"},\"wordCount\":161,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/\",\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"datePublished\":\"2021-09-22T05:25:29+00:00\",\"dateModified\":\"2025-04-01T07:22:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"width\":2560,\"height\":1575},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de","og_description":"\u591a\u80fd\u6027\u5e79\u7d30\u80de\u3068\u306f\uff1f \u30d2\u30c8\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306f\u3001\u81ea\u5df1\u3092\u969b\u9650\u306a\u304f\u518d\u751f\u3057\u3001\u9069\u5207\u306a\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3044\u3066\u30d2\u30c8\u4f53\u5185\u306b\u5b58\u5728\u3059\u308b\u307b\u307c\u5168\u3066\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u3002PSC\u306f\u3001\u80da\u6027\u5e79\u7d30\u80de\uff08ESC\uff09\u3068\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-09-22T05:25:29+00:00","article_modified_time":"2025-04-01T07:22:13+00:00","og_image":[{"width":2560,"height":1575,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de","datePublished":"2021-09-22T05:25:29+00:00","dateModified":"2025-04-01T07:22:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/"},"wordCount":161,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/","name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","datePublished":"2021-09-22T05:25:29+00:00","dateModified":"2025-04-01T07:22:13+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","width":2560,"height":1575},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea71\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-1024x630.jpg",760,468,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":10050,"position":0},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":10050,"position":1},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":10050,"position":2},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":10050,"position":3},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":10050,"position":4},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":10050,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=10050"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10050\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10097"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=10050"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=10050"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=10050"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=10050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}