{"id":10059,"date":"2021-09-24T15:01:38","date_gmt":"2021-09-24T06:01:38","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=10059"},"modified":"2025-04-01T16:22:32","modified_gmt":"2025-04-01T07:22:32","slug":"antibody_characterization_pca_bid_ts_2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/","title":{"rendered":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09"},"content":{"rendered":"<h2>\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\u3068\u306f\uff1f<\/h2>\n<p>\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u3068\u306f\u3001\u3042\u3089\u3086\u308b\u5e79\u7d30\u80de\u3068\u540c\u69d8\u306b\u9577\u671f\u306e\u81ea\u5df1\u8907\u88fd\u80fd\u3092\u6301\u3061\u3001\u7279\u5b9a\u306e\u6a5f\u80fd\u3092\u6301\u3064\u7279\u6b8a\u5316\u3057\u305f\u7d30\u80de\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u3001\u7279\u6b8a\u5316\u3057\u3066\u3044\u306a\u3044\u7d30\u80de\u3067\u3059\u3002\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u3001\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u3068\u306f\u7570\u306a\u308a\u3001\u69d8\u3005\u306a\u7d30\u80de\u30bf\u30a4\u30d7\u3078\u306e\u5206\u5316\u80fd\u304c\u9650\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u8a98\u5c0e\u3055\u308c\u305f\u5206\u5316\u7d30\u80de\u306f\u6570\u3082\u9650\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u3086\u3048\u3001\u6210\u4f53\u5e79\u7d30\u80de\u3001\u3088\u308a\u6b63\u78ba\u306b\u306f\u4f53\u6027\u5e79\u7d30\u80de\u3068\u547c\u3070\u308c\u308b\u7d30\u80de\u306f\u3001\u591a\u5206\u5316\u6027\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u306a\u305c\u306a\u3089\u3001\u5206\u5316\u80fd\u304c\u7279\u5b9a\u306e1\u3064\u307e\u305f\u306f\u8907\u6570\u306e\u7d30\u80de\u7a2e\u306b\u9650\u3089\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u9aa8\u9ac4\u5185\u306e\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u5168\u3066\u306e\u8840\u6db2\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u3001\u8133\u5185\u306e\u795e\u7d4c\u5e79\u7d30\u80de\u306f\u30b0\u30ea\u30a2\u7d30\u80de\u304a\u3088\u3073\u795e\u7d4c\u7d30\u80de\u306b\u5206\u5316\u53ef\u80fd\u3067\u3059\u304c\u3001 \u4ed6\u306e\u7d30\u80de\u306b\u306f\u5206\u5316\u3067\u304d\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u9593\u8449\u7cfb\u5e79\u7d30\u80de\uff08MSC\uff09\u3068\u3057\u3066\u77e5\u3089\u308c\u308b\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u7279\u6b8a\u306a\u5e79\u7d30\u80de\u306f\u3001\u9aa8\u3001\u7b4b\u8089\u3001\u8edf\u9aa8\u3001\u8102\u80aa\u304a\u3088\u3073\u4ed6\u306e\u985e\u4f3c\u3057\u305f\u7d44\u7e54\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n\u6210\u4f53\u5e79\u7d30\u80de\u306f\u3001\u8133\u3001\u6b6f\u3001\u9aa8\u9ac4\u3001\u672b\u68a2\u8840\u3001\u9aa8\u683c\u7b4b\u304a\u3088\u3073\u7cbe\u5de3\u306a\u3069\u306e\u69d8\u3005\u306a\u7d44\u7e54\u306b\u304a\u3051\u308b\u5e79\u7d30\u80de\u30cb\u30c3\u30c1\u306b\u5b58\u5728\u3057\u307e\u3059\uff08\u56f33.1\uff09\u3002\u6210\u4f53\u5e79\u7d30\u80de\u306f\u3001\u7d44\u7e54\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3055\u3089\u306a\u308b\u7d30\u80de\u304c\u5fc5\u8981\u3068\u3055\u308c\u308b\u901a\u5e38\u306e\u30cb\u30fc\u30ba\u306b\u3088\u3063\u3066\u3001\u3042\u308b\u3044\u306f\u4fee\u5fa9\u304c\u5fc5\u8981\u3068\u3055\u308c\u308b\u75be\u60a3\u3084\u7d44\u7e54\u640d\u50b7\u306b\u3088\u3063\u3066\u6d3b\u6027\u5316\u3055\u308c\u308b\u307e\u3067\u306e\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u4f11\u6b62\uff08\u672a\u5206\u5316\uff09\u72b6\u614b\u304c\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u6210\u4f53\u5e79\u7d30\u80de\u306f\u3001\u9577\u5e74\u306b\u308f\u305f\u308a\u3001\u9aa8\u9ac4\u79fb\u690d\u3092\u4ecb\u3059\u308b\u767d\u8840\u75c5\u306e\u6cbb\u7642\u3001\u306a\u3089\u3073\u306b\u8133\u304a\u3088\u3073\u810a\u9ac4\u640d\u50b7\u306e\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u591a\u304f\u306e\u524d\u81e8\u5e8a\u8a66\u9a13\u304a\u3088\u3073\u81e8\u5e8a\u8a66\u9a13\u306b\u304a\u3044\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10066\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-3.jpg\" alt=\"\" width=\"411\" height=\"433\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-3.jpg 411w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-3-285x300.jpg 285w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/><\/p>\n<h2>\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3<\/h2>\n<h3>\u9593\u8449\u7cfb\u5e79\u7d30\u80de<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/stem-cell-research\/mesenchymal-stem-cells.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u9593\u8449\u7cfb\u5e79\u7d30\u80de<\/a>\u306f\u3001\u6570\u5341\u5e74\u524d\u306b\u521d\u3081\u3066\u9aa8\u9ac4\u304b\u3089\u63a1\u53d6\u3055\u308c\u3001\u591a\u69d8\u306a\u6a5f\u80fd\u3092\u679c\u305f\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c in vitro \u304a\u3088\u3073 in vivo \u3067\u793a\u3055\u308c\u307e\u3057\u305f<sup>*1<\/sup>\u3002MSC\u306f\u9aa8\u9ac4\u306b\u304a\u3051\u308b\u5e79\u7d30\u80de\u30cb\u30c3\u30c1\u306b\u5bc4\u4e0e\u3057\u3001\u5e73\u6ed1\u7b4b\u3001\u8102\u80aa\u7d30\u80de\u3001\u9aa8\u3001\u304a\u3088\u3073\u8edf\u9aa8\u306e\u767a\u9054\u3068\u4fee\u5fa9\u306b\u5bc4\u4e0e\u3057\u3001\u901a\u5e38\u3001\u5927\u90e8\u5206\u306e\u7d44\u7e54\u304a\u3088\u3073\u5668\u5b98\u306e\u67d4\u7d44\u7e54\u306b\u5bc4\u4e0e\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059(\u56f33.2\uff09\u3002MSC\u306f\u305f\u3001\u591a\u69d8\u306a\u6210\u9577\u56e0\u5b50\u3001\u30b1\u30e2\u30ab\u30a4\u30f3\u3001\u304a\u3088\u3073\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u5206\u6ccc\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u91cd\u8981\u306a\u6804\u990a\u6a5f\u80fd\u3092\u767a\u63ee\u3057\u3001\u7d30\u80de\u5897\u6b96\u3001\u8840\u7ba1\u65b0\u751f\u3001\u6297\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3001\u304a\u3088\u3073\u6297\u708e\u75c7\u53cd\u5fdc\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u9593\u8449\u7cfb\u5e79\u7d30\u80de\u7814\u7a76\u306e\u9032\u6b69\u306b\u3088\u3063\u3066\u3001\u3053\u308c\u3089\u306e\u5e79\u7d30\u80de\u304c\u514d\u75ab\u8abf\u7bc0\u7642\u6cd5\uff08\u3059\u306a\u308f\u3061\u3001\u79fb\u690d\u7247\u5bfe\u5bbf\u4e3b\u75c5\u3084\u30af\u30ed\u30fc\u30f3\u75c5\u306e\u4e88\u9632\uff09\u306a\u3069\u306e\u69d8\u3005\u306a\u81e8\u5e8a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u304a\u3088\u3073\u9aa8\u3084\u8edf\u9aa8\u306a\u3069\u306e\u9593\u8449\u7d44\u7e54\u306e\u305f\u3081\u306e\u7d30\u80de\u7f6e\u63db\u7642\u6cd5\u306b\u304a\u3044\u3066\u3001\u3069\u306e\u3088\u3046\u306b\u4f7f\u7528\u53ef\u80fd\u304b\u306b\u3064\u3044\u3066\u660e\u3089\u304b\u306b\u3055\u308c\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002MSC\u306f\u3001\u9aa8\u9ac4\u3001\u8102\u80aa\u7d44\u7e54\u3001\u8840\u6db2\u3001\u771f\u76ae\u3001\u80ce\u76e4\u3001\u81cd\u5e2f\u3001\u9aa8\u683c\u7b4b\u3001\u304a\u3088\u3073\u4e73\u6b6f\u306a\u3069\u306e\u69d8\u3005\u306a\u7d44\u7e54\u304b\u3089\u5206\u96e2\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u69d8\u3005\u306aMSC\u96c6\u56e3\u306f\u5f62\u614b\uff08\u4e0d\u5747\u4e00\u6027\uff09\u3001\u6210\u9577\u3001\u304a\u3088\u3073\u5206\u5316\u80fd\u306b\u304a\u3044\u3066\u76f8\u9055\u304c\u3042\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u7d30\u80de\u306b\u306f\u5171\u901a\u306b\u6301\u3064\u7279\u6027\u304c\u5b58\u5728\u3057\u307e\u3059\u3002International Society for Cell Therapy (ISCT) \u306e\u63d0\u6848\u3059\u308b in vitro \u57f9\u990a\u7d30\u80de\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u57fa\u3065\u304f\u57fa\u6e96<sup>*2<\/sup>\u3067\u306f\u3001MSC\u306f\u3001\u7d30\u80de\u8868\u9762\u30de\u30fc\u30ab\u30fcCD73\u3001CD90\u3001\u304a\u3088\u3073CD105\u3092\u767a\u73fe\u3057\u3001CD34\u3001CD45\u3001CD14\u3001HLA-DR\u3001CD11b\u3001\u304a\u3088\u3073CD79a\u3092\u767a\u73fe\u3057\u306a\u3044\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\nin vivo \u306e\u8868\u73fe\u578b\u7814\u7a76\u306b\u304a\u3044\u3066\u3001MSC\u306fCD146\u3001Stro-1\u3001CD90\u3001CD105\u3001CD44\u3001\u304a\u3088\u3073CD73\u304c\u967d\u6027\u3001CD45\u3001CD11b\u3001\u304a\u3088\u3073CD14\u304c\u9670\u6027\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u3055\u308c\u307e\u3057\u305f\uff08\u56f3 3.3\uff09\u3002\u5f0a\u793e\u306f\u3001MSC\u7528\u4e00\u6b21\u6297\u4f53\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u591a\u304f\u306eISCT\u306b\u3088\u3063\u3066\u540c\u5b9a\u3055\u308c\u305f\u30d2\u30c8MSC\u3092\u5b9a\u7fa9\u3059\u308b\u305f\u3081\u306e\u30dd\u30b8\u30c6\u30a3\u30d6\u30de\u30fc\u30ab\u30fc\u3068\u30cd\u30ac\u30c6\u30a3\u30d6\u30de\u30fc\u30ab\u30fc\u304c\u542b\u307e\u308c\u307e\u3059\uff08\u88683.1\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10067\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-1.jpg\" alt=\"\" width=\"401\" height=\"346\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-1.jpg 401w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-1-300x259.jpg 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10068\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-1.jpg\" alt=\"\" width=\"403\" height=\"488\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-1.jpg 403w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-1-248x300.jpg 248w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10060\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-1.jpg\" alt=\"\" width=\"398\" height=\"891\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-1.jpg 398w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-1-134x300.jpg 134w\" sizes=\"auto, (max-width: 398px) 100vw, 398px\" \/><br \/>\n\u30d2\u30c8MSC\u306f\u3001\u9069\u5207\u306a\u57f9\u990a\u6761\u4ef6\u4e0b\u3067\u3001\u8102\u80aa\u7d30\u80de\uff08\u8102\u80aa\uff09\u3001\u8edf\u9aa8\u7d30\u80de\uff08\u8edf\u9aa8\uff09\u3001\u304a\u3088\u3073\u9aa8\u82bd\u7d30\u80de\uff08\u9aa8\uff09\u306b\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u6301\u3061\u307e\u3059\uff08\u56f33.4\uff09\u3002<br \/>\n\u9aa8\u9ac4\u7531\u6765\u306eMSC\u306f\u3001\u30c7\u30b9\u30df\u30f3\u3001\u03b2-\u30df\u30aa\u30b7\u30f3\u91cd\u9396\u3001\u5fc3\u7b4b\u03b1-\u30a2\u30af\u30c1\u30f3\u3001\u304a\u3088\u3073\u4ed6\u306e\u7b4b\u8089\u7d30\u80de\u30de\u30fc\u30ab\u30fc\u3092\u767a\u73fe\u3059\u308b\u7b4b\u7d30\u80de\uff08\u7b4b\u8089\u7d30\u80de\uff09\u306a\u3069\u306e\u4ed6\u306e\u4e2d\u80da\u8449\u7531\u6765\u306e\u7d44\u7e54\u306b\u3082\u5206\u5316\u3059\u308b\u80fd\u529b\u3092\u6301\u3061\u307e\u3059\u3002Wnt\/\u03b2-\u30ab\u30c6\u30cb\u30f3\u7d4c\u8def\u304a\u3088\u3073 TGF\u03b2\/Smad \u7d4c\u8def\u306f\u3001MSC \u5206\u5316\u306e\u8abf\u7bc0\u306b\u304a\u3044\u3066\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002Wnt\/\u03b2-\u30ab\u30c6\u30cb\u30f3\u7d4c\u8def\u306f\u3001\u9aa8\u82bd\u7d30\u80de\u5897\u6b96\u304a\u3088\u3073\u8edf\u9aa8\u5206\u5316\u3092\u6291\u5236\u3059\u308b\u3053\u3068\u306b\u3088\u308b\u9aa8\u683c\u5f62\u6210\u306e\u4fc3\u9032\u306b\u304a\u3044\u3066\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001TGF\u03b2\u7d4c\u8def\u306f MSC \u306b\u304a\u3051\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u3092\u30a2\u30c3\u30d7\u30ec\u30ae\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3057\u3001\u8edf\u9aa8\u5206\u5316\u3092\u4fc3\u9032\u3057\u307e\u3059<sup>*3<\/sup>\u3002\u88683.2\u306b\u3001\u69d8\u3005\u306a\u9593\u8449\u7d30\u80de\u7cfb\u7d71\u304b\u3089\u8a98\u5c0e\u3055\u308c\u5f97\u308b\u69d8\u3005\u306a\u7d30\u80de\u30bf\u30a4\u30d7\u306e\u4ee3\u8868\u7684\u306a\u30de\u30fc\u30ab\u30fc\u304a\u3088\u3073\u5f0a\u793e\u304c\u63d0\u4f9b\u3057\u3066\u3044\u308b\u4ee3\u8868\u7684\u306a\u6297\u4f53\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10061\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-1.jpg\" alt=\"\" width=\"397\" height=\"514\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-1.jpg 397w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-1-232x300.jpg 232w\" sizes=\"auto, (max-width: 397px) 100vw, 397px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10062\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-1.jpg\" alt=\"\" width=\"810\" height=\"908\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-1.jpg 810w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-1-268x300.jpg 268w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-1-768x861.jpg 768w\" sizes=\"auto, (max-width: 810px) 100vw, 810px\" \/><\/p>\n<h3>\u9020\u8840\u5e79\u7d30\u80de<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/stem-cell-research\/hematopoietic-stem-cells.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u9020\u8840\u5e79\u7d30\u80de\uff08HSC\uff09<\/a>\u306f\u3001B\u30ea\u30f3\u30d1\u7403\u304a\u3088\u3073T\u30ea\u30f3\u30d1\u7403\u3001\u30ca\u30c1\u30e5\u30e9\u30eb\u30ad\u30e9\u30fc\u7d30\u80de\u3001\u6a39\u72b6\u7d30\u80de\u3001\u5358\u7403\u3001\u8840\u5c0f\u677f\u3001\u306a\u3089\u3073\u306b\u8d64\u8840\u7403\u306a\u3069\u306e\u8840\u6db2\u306e\u3042\u3089\u3086\u308b\u7d30\u80de\u30bf\u30a4\u30d7\u306b\u5206\u5316\u3059\u308b\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u3067\u3059\uff08\u56f33.5\uff09\u3002\u9020\u8840\u306e\u5909\u52d5\u306f\u3001\u767d\u8840\u75c5\u3001\u30ea\u30f3\u30d1\u816b\u3001\u304a\u3088\u3073\u8ca7\u8840\u306a\u3069\u306e\u69d8\u3005\u306a\u75be\u60a3\u3068\u95a2\u4fc2\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u6307\u6458\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002HSC\u79fb\u690d\u304a\u3088\u3073\u9020\u8840\u7d30\u80de\u306e\u6ce8\u5165\u306f\u3001\u767d\u8840\u75c5\u3084\u4ed6\u306e\u30bf\u30a4\u30d7\u306e\u8840\u6db2\u75be\u60a3\u306e\u6cbb\u7642\u306b\u5e45\u5e83\u304f\u81e8\u5e8a\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002HSC\u306f\u9aa8\u9ac4\u3001\u672b\u68a2\u8840\u3001\u304a\u3088\u3073\u81cd\u5e2f\u8840\u306b\u5b58\u5728\u3057\u307e\u3059\u3002\u30d2\u30c8\u767d\u8840\u7403\u6297\u539f\u9069\u5408\u30c9\u30ca\u30fc\u306e\u4e0d\u8db3\u3068\u79fb\u690d\u53ef\u80fd\u306a\u7d30\u80de\u6570\u304c\u9650\u3089\u308c\u3066\u3044\u308b\u3053\u3068\u306f\u3001HSC\u306e\u6cbb\u7642\u3078\u306e\u4f7f\u7528\u306e\u59a8\u3052\u3068\u306a\u308a\u307e\u3059\u3002\u8fd1\u5e74\u306e\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u6280\u8853\u304a\u3088\u3073\u30d2\u30c8PSC\u304b\u3089\u306e\u9020\u8840\u5206\u5316\u306e\u9032\u6b69\u306f\u3001\u9020\u8840\u767a\u751f\u3092\u7814\u7a76\u3001\u8840\u6db2\u75be\u60a3\u3092\u30e2\u30c7\u30ea\u30f3\u30b0\u3057\u3001\u79fb\u690d\u304a\u3088\u3073\u304c\u3093\u6cbb\u7642\u7528\u3068\u3057\u3066\u514d\u75ab\u5b66\u7684\u306b\u9069\u5408\u3059\u308b\u7d30\u80de\u3092\u4f5c\u88fd\u3059\u308b\u305f\u3081\u306e\u65b0\u3057\u3044\u6a5f\u4f1a\u3092\u63d0\u4f9b\u3057\u3066\u304d\u3066\u3044\u307e\u3059<sup>*4<\/sup>\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10063\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-1.jpg\" alt=\"\" width=\"397\" height=\"343\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-1.jpg 397w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-1-300x259.jpg 300w\" sizes=\"auto, (max-width: 397px) 100vw, 397px\" \/><br \/>\nPSC\u304b\u3089HSC\u3092\u5206\u5316\u8a98\u5c0e\u3059\u308b\u305f\u3081\u306e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u306f\u73fe\u5728\u6700\u9069\u5316\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30d2\u30c8PSC\u304b\u3089\u306e\u9020\u8840\u7d30\u80de\u5206\u5316\u306f\u3001 in vivo \u3067\u306e\u80da\u306e\u9020\u8840\u3068\u985e\u4f3c\u3057\u305f\u5206\u5316\u6bb5\u968e\u3092\u7d4c\u3066\u6210\u719f\u3059\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff08\u56f33.6\uff09\u3002\u7c21\u6f54\u306b\u306f\u3001\u4e2d\u80da\u8449\u8a98\u5c0e\u306b\u3088\u3063\u3066Brachyury\u3001APLNR\u3001\u304a\u3088\u3073KDR\u306a\u3069\u306e\u521d\u671f\u4e2d\u80da\u8449\u30de\u30fc\u30ab\u30fc\u3092\u767a\u73fe\u3059\u308b\u7d30\u80de\u306e\u751f\u6210\u306b\u7d9a\u304d\u3001\u9020\u8840\u306b\u304a\u3051\u308b\u7cfb\u7d71\u304c\u6c7a\u5b9a\u3055\u308c\u3001GATA2\u304a\u3088\u3073SCL\u3092\u767a\u73fe\u3059\u308b\u8840\u6db2\u8840\u7ba1\u6027\u4e2d\u80da\u8449\u524d\u99c6\u7d30\u80de\u304c\u8a98\u5c0e\u3055\u308c\u307e\u3059\u3002\u7d9a\u3044\u3066\u3001CD34\u3092\u767a\u73fe\u3059\u308b\u9020\u8840\u5e79\u7d30\u80de\u3001CD43\u3092\u30a2\u30c3\u30d7\u30ec\u30ae\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u9020\u8840\u524d\u99c6\u7d30\u80de\uff08HPC\uff09\u3001\u304a\u3088\u3073\u6210\u719f\u9020\u8840\u7d30\u80de\u304c\u767a\u751f\u3057\u307e\u3059\uff08\u88683.3\uff09\u3002<br \/>\nHSC\u306f\u3001\u7cbe\u88fd\u3084\u9855\u5fae\u93e1\u306b\u3088\u308b\u53ef\u8996\u5316\u304c\u56f0\u96e3\u306a\u5c0f\u3055\u3044\u975e\u63a5\u7740\u6027\u7d30\u80de\u3067\u3059\u3002\u4e00\u822c\u7684\u306b\u3001HSC\u306f\u9759\u6b62\u72b6\u614b\u306b\u304a\u3044\u3066\u3001\u69d8\u3005\u306a\u7d30\u80de\u8868\u9762\u6297\u539f\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b10\uff5e14\u7a2e\u985e\u306e\u6297\u4f53\u30d1\u30cd\u30eb\u3092\u4f7f\u7528\u3059\u308b\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306b\u3088\u3063\u3066\u540c\u5b9a\u3055\u308c\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30de\u30a6\u30b9HSC\u306f\u3001Lin\u2013\uff08\u7d30\u80de\u7cfb\u30de\u30fc\u30ab\u30fc\uff09\u3001Sca-1+(\u5e79\u7d30\u80de\u304a\u3088\u3073\u524d\u99c6\u7d30\u80de\u306e\u63a8\u5b9a\u30de\u30fc\u30ab\u30fc)\u3001cKit\/CD117+(SCF\u53d7\u5bb9\u4f53)\u3001\u304a\u3088\u3073Tie-2+(\u5185\u76ae\u7d30\u80de\u304a\u3088\u3073\u9020\u8840\u7d30\u80de\u306b\u304a\u3044\u3066\u767a\u73fe\u3055\u308c\u308b\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bc\u53d7\u5bb9\u4f53)\u306b\u3088\u3063\u3066\u5b9a\u7fa9\u3055\u308c\u308b\u306e\u306b\u5bfe\u3057\u3001\u30d2\u30c8HSC\u306f\u3001CD34+\u3001CD59+\u3001Thy1\/CD90+\u3001CD38lo\/\u2013\u3001cKit\/CD117+\u3001Lin\u2013\u3001\u304a\u3088\u3073CD43+\u3068\u3044\u3046\u7279\u6027\u3092\u6301\u3061\u307e\u3059\uff08\u56f33.7\u304a\u3088\u3073\u88683.3\uff09\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10064\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig8.jpg\" alt=\"\" width=\"398\" height=\"295\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig8.jpg 398w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig8-300x222.jpg 300w\" sizes=\"auto, (max-width: 398px) 100vw, 398px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-10065\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig9.jpg\" alt=\"\" width=\"817\" height=\"831\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig9.jpg 817w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig9-295x300.jpg 295w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig9-768x781.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig9-80x80.jpg 80w\" sizes=\"auto, (max-width: 817px) 100vw, 817px\" \/><\/p>\n<p><strong>\u53c2\u8003\u6587\u732e:<\/strong><br \/>\n1. Murphy MB, Moncivais K, Caplan AI (2013) Mesenchymal stem cells: environmentally responsive therapeutics for regenerative medicine. Exp Mol Med 45:e54.<br \/>\n2. Dominici M, Le Blanc K, Mueller I et al. (2006) Minimal criteria for defining multipotent mesenchymal stromal cells. The International Society for Cellular Therapy position statement. Cytotherapy 8(4):315\u2013317.<br \/>\n3. Williams AR, Hare JM (2011) Mesenchymal stem cells: biology, pathophysiology, translational findings, and therapeutic implications for cardiac disease. Circ Res 109(8):923\u2013940.<br \/>\n4. Lim WF, Inoue-Yokoo T, Tan KS et al (2013) Hematopoietic cell differentiation from embryonic and induced pluripotent stem cells. Stem Cell Res Ther 4(3):71.<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u5e79\u7d30\u80de\u7814\u7a76\u7528\u6297\u4f53\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u672c\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u5e79\u7d30\u80de\u7814\u7a76\u306b\u95a2\u3059\u308b\u6df1\u3044\u77e5\u8b58\u306e\u7fd2\u5f97\u3001\u304a\u3088\u3073\u6700\u65b0\u306e\u7814\u7a76\u306b\u5f79\u7acb\u3064\u6297\u4f53\u95a2\u9023\u88fd\u54c1\u306e\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/en\/home\/global\/forms\/antibody-stem-cell-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\u3068\u306f\uff1f \u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u3068\u306f\u3001\u3042\u3089\u3086\u308b\u5e79\u7d30\u80de\u3068\u540c\u69d8\u306b\u9577\u671f\u306e\u81ea\u5df1\u8907\u88fd\u80fd\u3092\u6301\u3061\u3001\u7279\u5b9a\u306e\u6a5f\u80fd\u3092\u6301\u3064\u7279\u6b8a\u5316\u3057\u305f\u7d30\u80de\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u3001\u7279\u6b8a\u5316\u3057\u3066\u3044\u306a\u3044\u7d30\u80de\u3067\u3059\u3002\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u3001\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08<\/p>\n","protected":false},"author":975,"featured_media":10097,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-10059","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\" \/>\n<meta property=\"og:description\" content=\"\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\u3068\u306f\uff1f \u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u3068\u306f\u3001\u3042\u3089\u3086\u308b\u5e79\u7d30\u80de\u3068\u540c\u69d8\u306b\u9577\u671f\u306e\u81ea\u5df1\u8907\u88fd\u80fd\u3092\u6301\u3061\u3001\u7279\u5b9a\u306e\u6a5f\u80fd\u3092\u6301\u3064\u7279\u6b8a\u5316\u3057\u305f\u7d30\u80de\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u3001\u7279\u6b8a\u5316\u3057\u3066\u3044\u306a\u3044\u7d30\u80de\u3067\u3059\u3002\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u3001\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-24T06:01:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T07:22:32+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1575\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\",\"datePublished\":\"2021-09-24T06:01:38+00:00\",\"dateModified\":\"2025-04-01T07:22:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/\"},\"wordCount\":185,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/\",\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"datePublished\":\"2021-09-24T06:01:38+00:00\",\"dateModified\":\"2025-04-01T07:22:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"width\":2560,\"height\":1575},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09","og_description":"\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09\u3068\u306f\uff1f \u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u3068\u306f\u3001\u3042\u3089\u3086\u308b\u5e79\u7d30\u80de\u3068\u540c\u69d8\u306b\u9577\u671f\u306e\u81ea\u5df1\u8907\u88fd\u80fd\u3092\u6301\u3061\u3001\u7279\u5b9a\u306e\u6a5f\u80fd\u3092\u6301\u3064\u7279\u6b8a\u5316\u3057\u305f\u7d30\u80de\u306b\u5206\u5316\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u3001\u7279\u6b8a\u5316\u3057\u3066\u3044\u306a\u3044\u7d30\u80de\u3067\u3059\u3002\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\u306f\u3001\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-09-24T06:01:38+00:00","article_modified_time":"2025-04-01T07:22:32+00:00","og_image":[{"width":2560,"height":1575,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09","datePublished":"2021-09-24T06:01:38+00:00","dateModified":"2025-04-01T07:22:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/"},"wordCount":185,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/","name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","datePublished":"2021-09-24T06:01:38+00:00","dateModified":"2025-04-01T07:22:32+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","width":2560,"height":1575},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea72\u3000\u591a\u5206\u5316\u80fd\u5e79\u7d30\u80de\uff08\u5206\u5316\u8907\u80fd\u6027\u5e79\u7d30\u80de\uff09"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-1024x630.jpg",760,468,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":10059,"position":0},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":10059,"position":1},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":10059,"position":2},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":10059,"position":3},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":10059,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":10059,"position":5},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=10059"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10059\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10097"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=10059"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=10059"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=10059"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=10059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}