{"id":10084,"date":"2021-09-29T16:18:45","date_gmt":"2021-09-29T07:18:45","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=10084"},"modified":"2025-04-01T16:22:50","modified_gmt":"2025-04-01T07:22:50","slug":"antibody_characterization_pca_bid_ts_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/","title":{"rendered":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316"},"content":{"rendered":"<p>\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306e\u91cd\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e00\u3064\u306b\u7d30\u80de\u7642\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6162\u6027\u809d\u75be\u60a3\u3001\u7cd6\u5c3f\u75c5\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u6cbb\u7642\u7814\u7a76\u306b\u6d3b\u7528\u3067\u304d\u308b\u3001PSC\u304a\u3088\u3073\u305d\u306e\u5206\u5316\u8a98\u5c0e\u4f53\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u80da\u4f53\uff08\u80da\u6027\uff09\u5185\u80da\u8449\u3001\u809d\u7d30\u80de\u3001\u304a\u3088\u3073\u81b5\u03b2\u7d30\u80de\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p>\u6162\u6027\u809d\u75be\u60a3\u304a\u3088\u3073\u7cd6\u5c3f\u75c5\u306f\u3001\u5168\u4e16\u754c\u306e\u7f79\u60a3\u8005\u6570\u304c\u305d\u308c\u305e\u308c600\u4e07\u4eba\u304a\u3088\u3073300\u4e07\u4eba\u4ee5\u4e0a\u306b\u53ca\u3076\u75be\u60a3\u3067\u3059\u3002\u30c9\u30ca\u30fc\u7d30\u80de\u306e\u4e0d\u8db3\u3068\u8cea\u306e\u4f4e\u3055\u304b\u3089\u3001\u79fb\u690d\u53ef\u80fd\u306a\u7d44\u7e54\u306b\u5bfe\u3059\u308b\u9700\u8981\u304c\u7740\u5b9f\u306b\u5897\u52a0\u3057\u3066\u304d\u3066\u304a\u308a\u3001PSC\u304b\u3089\u8a98\u5c0e\u3055\u308c\u305f\u79fb\u690d\u53ef\u80fd\u306a\u809d\u7d30\u80de\u304a\u3088\u3073\u03b2\u7d30\u80de\u306f\u7f79\u60a3\u8005\u306e\u6cbb\u7642\u306b\u975e\u5e38\u306b\u6709\u671b\u8996\u3055\u308c\u3066\u3044\u307e\u3059\u3002in vitro \u3067\u306e PSC\u304b\u3089\u306e\u6a5f\u80fd\u7684\u306a\u6210\u719f\u809d\u7d30\u80de\u304a\u3088\u3073\u81b5\u03b2\u7d30\u80de\u306e\u5206\u5316\u8a98\u5c0e\u306f\u56f0\u96e3\u3067\u3042\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u8fd1\u5e74\u3001\u6a5f\u80fd\u7684\u30b0\u30eb\u30b3\u30fc\u30b9\u5fdc\u7b54\u6027\u30a4\u30f3\u30b9\u30ea\u30f3\u5206\u6ccc\u03b2\u7d30\u80de1,2\u3084\u3044\u304f\u3089\u304b\u306e\u809d\u6a5f\u80fd\u6d3b\u6027\u3092\u6709\u3059\u308b\u809d\u7d30\u80de\u69d8\u7d30\u80de3\u306e\u5f62\u6210\u3092\u53ef\u80fd\u3068\u3059\u308b\u9023\u7d9a\u7684\u306a\u5206\u5316\u30b9\u30c8\u30e9\u30c6\u30b8\u30fc\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\u3002PSC\u306f\u3001\u307e\u305aSOX17\u3001FOXA2\u3001\u304a\u3088\u3073CXCR4\u3092\u767a\u73fe\u3059\u308b\u7d30\u80de\u304c\u6570\u591a\u304f\u542b\u307e\u308c\u308b\u80da\u4f53\uff08\u80da\u6027\uff09\u5185\u80da\u8449\u306b\u8a98\u5c0e\u3055\u308c\u307e\u3059\uff08\u56f34.1\u304a\u3088\u3073\u88684.1\uff09\u3002\u81b5\u81d3\u7cfb\u7d71\u3067\u306f\u3001\u80da\u4f53\uff08\u80da\u6027\uff09\u5185\u80da\u8449\u304b\u3089\u539f\u8178\u7ba1\uff08HNF1b+\/FoxA2+\uff09\u3001\u524d\u8178\u5f8c\u90e8\uff08PDX1+\/HNF6+\/SOX9+\uff09\u304c\u5f62\u6210\u3055\u308c\u3001\u7d9a\u3044\u3066\u521d\u671f\u81b5\u81d3\u524d\u99c6\u7d30\u80de\uff08PDX1+\/NKX6.1+\uff09\u304c\u542b\u307e\u308c\u308b\u81b5\u81d3\u5185\u80da\u8449\u304c\u5f62\u6210\u3055\u308c\u307e\u3059\u3002PDX1\uff08\u81b5\u81d3\u30db\u30e1\u30aa\u30c9\u30e1\u30a4\u30f3\u8ee2\u5199\u56e0\u5b50\uff09\uff08\u56f34.2\uff09\u304a\u3088\u3073NKX6.1\uff08\u30db\u30e1\u30aa\u30dc\u30c3\u30af\u30b9\u8ee2\u5199\u56e0\u5b50\uff09\u306f\u3001\u81b5\u5185\u5206\u6ccc\u524d\u99c6\u7d30\u80de\u3092\u5f62\u6210\u3059\u308b\u591a\u80fd\u6027\u524d\u99c6\u7d30\u80de\u306e\u30ad\u30fc\u30de\u30fc\u30ab\u30fc\u3067\u3059\u3002\u81b5\u5185\u5206\u6ccc\u524d\u99c6\u7d30\u80de\u306f\u3001\u6700\u521d\u306bNGN3\u3092\u767a\u73fe\u3057\u3001\u7d9a\u3044\u3066NEUROD1\u304a\u3088\u3073NKX2.2\u306e\u767a\u73fe\u3092\u8a98\u5c0e\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001PDX1+\/NKX6.1+\/NEUROD1+\u5185\u5206\u6ccc\u7d30\u80de\u306f\u3001\u30a4\u30f3\u30b9\u30ea\u30f3+\/\u30b0\u30eb\u30ab\u30b4\u30f3\u2013\/\u30bd\u30de\u30c8\u30b9\u30bf\u30c1\u30f3\u2013\u306e\u672a\u719f\u03b2\u7d30\u80de\u306b\u5206\u5316\u3057\u3001\u6700\u7d42\u7684\u306bUCN3\u3001MAFA\u3001\u304a\u3088\u3073C-\u30da\u30d7\u30c1\u30c9\u306a\u3069\u306e\u6210\u719f\u03b2\u7d30\u80de\u30de\u30fc\u30ab\u30fc\u3082\u767a\u73fe\u3059\u308b\u6210\u719f\u03b2\u7d30\u80de\u306b\u5206\u5316\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306ePSC\u304b\u3089\u8a98\u5c0e\u3055\u308c\u305f\u03b2\u7d30\u80de\u306f\u3001\u30b0\u30eb\u30b3\u30fc\u30b9\u523a\u6fc0\u306b\u5fdc\u7b54\u3057\u3066\u30a4\u30f3\u30b9\u30ea\u30f3\u306e\u5206\u6ccc\u304a\u3088\u3073Ca2+\u306e\u6d41\u5165\u3092\u5c0e\u304f\u3053\u3068\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u6a5f\u80fd\u7684\u306a\u03b2\u7d30\u80de\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u307e\u3059\u3002\u809d\u81d3\u7cfb\u7d71\u3067\u306f\u3001\u4eba\u5de5\u8a98\u5c0ePSC(iPSC)-\u7531\u6765\u809d\u7d30\u80de\u69d8\u7d30\u80de\uff08iHLC\uff09\u306f\u3001\u80da\u4f53\uff08\u80da\u6027\uff09\u5185\u80da\u8449\u304b\u3089\u306e\u6bb5\u968e\u7684\u306a\u5206\u5316\u3092\u7d4c\u3066\u5f62\u6210\u3055\u308c\u307e\u3059\u3002\u307e\u305a\u3001\u524d\u8178\u30fb\u809d\u306b\u7279\u6b8a\u5316\u3055\u308c\u305f\u5185\u80da\u8449\uff08HHEX+\u3001HNF1B+\u3001\u304a\u3088\u3073FOXA2+)\u3068\u306a\u308a\u3001\u7d9a\u3044\u3066\u809d\u82bd\u7d30\u80de\uff08\u03b1-\u30d5\u30a7\u30c8\u30d7\u30ed\u30c6\u30a4\u30f3+\u3001CK14+\u3001\u304a\u3088\u3073Prox1+\uff09\u3068\u306a\u308a\u3001\u305d\u306e\u5f8c\u3001\u30a2\u30eb\u30d6\u30df\u30f3\u3001\u03b11-\u30a2\u30f3\u30c1\u30c8\u30ea\u30d7\u30b7\u30f3\u3001\u304a\u3088\u3073\u03b1-\u30d5\u30a7\u30c8\u30d7\u30ed\u30c6\u30a4\u30f3\u306a\u3069\u306e\u30d7\u30ed\u30c8\u30bf\u30a4\u30d7\u306e\u809d\u7d30\u80de\u30de\u30fc\u30ab\u30fc\u3092\u767a\u73fe\u3059\u308biHLC\u306b\u6210\u719f\u3057\u307e\u3059\uff08\u56f34.1\u304a\u3088\u3073\u88684.1\uff09\u3002<br \/>\n\u6210\u719f\u30d2\u30c8\u809d\u7d30\u80de\u3068\u306f\u7570\u306a\u308a\u3001iHLC \u3067\u306f\u3001CYP3A4 \u304a\u3088\u3073 2A6 \u306a\u3069\u306e\u91cd\u8981\u306a\u89e3\u6bd2\u9175\u7d20\u306e\u767a\u73fe\u91cf\u304c\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002\u73fe\u5728\u3001iHLC\u3092\u3055\u3089\u306b\u6210\u719f\u3055\u305b\u3066\u3001\u6a5f\u80fd\u7684\u809d\u7d30\u80de\u3078\u5206\u5316\u8a98\u5c0e\u3059\u308b\u305f\u3081\u306e\u30b9\u30c8\u30e9\u30c6\u30b8\u30fc\u306e\u958b\u767a\u304c\u9032\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10089 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-4.jpg\" alt=\"\" width=\"373\" height=\"626\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-4.jpg 373w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig1-4-179x300.jpg 179w\" sizes=\"auto, (max-width: 373px) 100vw, 373px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10090 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-2.jpg\" alt=\"\" width=\"807\" height=\"852\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-2.jpg 807w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-2-284x300.jpg 284w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig2-2-768x811.jpg 768w\" sizes=\"auto, (max-width: 807px) 100vw, 807px\" \/><\/p>\n<h2>\u795e\u7d4c\u7cfb\u7d71<\/h2>\n<p>\u8fd1\u5e74\u306b\u304a\u3051\u308b\u5e79\u7d30\u80de\u751f\u7269\u5b66\u3001\u795e\u7d4c\u79d1\u5b66\u3001\u304a\u3088\u3073<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/stem-cell-research\/stem-cell-engineering-reprogramming.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u6280\u8853<\/a>\u306e\u7406\u89e3\u306e\u9032\u6b69\u306f\u3001\u4e0d\u6cbb\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u304a\u3088\u3073\u30cb\u30e5\u30fc\u30ed\u30f3\u640d\u50b7\u306e\u6709\u671b\u306a\u6cbb\u7642\u3092\u958b\u767a\u3059\u308b\u305f\u3081\u306e\u7814\u7a76\u306e\u65b0\u3057\u3044\u9053\u3092\u5207\u308a\u958b\u304d\u307e\u3057\u305f<sup>*1<\/sup> \u3002 \u5e79\u7d30\u80de\u306f\u3001\u81ea\u5df1\u8907\u88fd\u3057\u3001\u5206\u5316\u3057\u305f\u7d30\u80de\u3092\u751f\u3058\u3055\u305b\u308b\u80fd\u529b\u3092\u6301\u3064\u305f\u3081\u3001\u4e2d\u67a2\u30fb\u672b\u68a2\u795e\u7d4c\u7cfb\u306e\u969c\u5bb3\u304a\u3088\u3073\u640d\u50b7\u306b\u5bfe\u3059\u308b\u5e79\u7d30\u80de\u88dc\u5145\u7642\u6cd5\u306f\u7f79\u60a3\u3057\u305f\u795e\u7d4c\u7d44\u7e54\u306b\u30cb\u30e5\u30fc\u30ed\u30f3\u3084\u4ed6\u306e\u795e\u7d4c\u7d30\u80de\u3092\u518d\u914d\u7f6e\u3055\u305b\u308b\u3088\u3046\u306b\u50cd\u304d\u307e\u3059\u3002\u3053\u306e\u76ee\u7684\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306e\u4e3b\u8981\u306a\u30b9\u30c8\u30e9\u30c6\u30b8\u30fc\u306e\u4e00\u3064\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/stem-cell-research\/neural-stem-cells.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u795e\u7d4c\u5e79\u7d30\u80de<\/a>\u306e\u5185\u5728\u6027\u518d\u751f\u80fd\u529b\u3092\u6d3b\u6027\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u3042\u308b\u3044\u306f\u795e\u7d4c\u7d30\u80de\u307e\u305f\u306f\u80da\u7d30\u80de\u3092\u79fb\u690d\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u795e\u7d4c\u7cfb\u306e\u6b63\u5e38\u306a\u767a\u9054\u3092\u518d\u73fe\u3059\u308b\u3053\u3068\u306b\u72d9\u3044\u3092\u5b9a\u3081\u3066\u3044\u307e\u3059\u3002<br \/>\n\u54fa\u4e73\u985e\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u65b0\u751f\u306f\u3001\u795e\u7d4c\u5916\u80da\u8449\u306e\u8a98\u5c0e\u306b\u59cb\u307e\u308a\u3001\u795e\u7d4c\u677f\u304c\u5f62\u6210\u3055\u308c\u305f\u5f8c\u3001\u305d\u308c\u304c\u9686\u8d77\u3057\u3066\u30d2\u30c0\u3068\u306a\u308a\u795e\u7d4c\u7ba1\u304c\u5f62\u6210\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u69cb\u9020\u306f\u3001\u795e\u7d4c\u4e0a\u76ae\u524d\u99c6\u7d30\u80de\uff08NEP\uff09\u306e\u5c64\u304b\u3089\u5f62\u6210\u3055\u308c\u307e\u3059\u3002NEP\u306f\u8fc5\u901f\u306b\u539f\u59cb\u795e\u7d4c\u5e79\u7d30\u80de\uff08NSC\uff09\u306b\u5909\u63db\u3055\u308c\u307e\u3059<sup>*2<\/sup>\u3002NSC\u306f\u81ea\u5df1\u8907\u88fd\u80fd\u3092\u6301\u3064\u591a\u5206\u5316\u6027\u524d\u99c6\u7d30\u80de\u3067\u3001\u6210\u4f53\u306a\u3069\u306e\u4e2d\u67a2\u795e\u7d4c\u7cfb\u306b\u5b58\u5728\u3057\u307e\u3059\u3002NSC\u304a\u3088\u3073\u795e\u7d4c\u524d\u99c6\u7d30\u80de\u306f\u3001\u767a\u751f\u4e2d\u306b\u308f\u305f\u3063\u3066\u5b58\u5728\u3057\u3001\u6210\u4f53\u795e\u7d4c\u7cfb\u306b\u3082\u5b58\u5728\u3057\u7d9a\u3051\u307e\u3059\u3002\u8907\u6570\u306e\u30af\u30e9\u30b9\u306eNSC\u306f\u3001\u4e92\u3044\u306b\u5206\u5316\u80fd\u529b\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u53cd\u5fdc\u6027\u3001\u304a\u3088\u3073\u8868\u9762\u6297\u539f\u7279\u6027\u304c\u7570\u306a\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002in vitro \u3067\u3001\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u304b\u3089\u8a98\u5c0e\u3055\u308c\u305fNSC\u306f\u3001\u8ee2\u5199\u56e0\u5b50SOX1\u3001SOX2\u3001PAX6\u3001\u304a\u3088\u3073VI\u578b\u4e2d\u9593\u7cfb\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u30cd\u30b9\u30c1\u30f3\u306a\u3069\u306e\u7279\u5b9a\u306e\u4e00\u9023\u306e\u30de\u30fc\u30ab\u30fc\u3092\u767a\u73fe\u3059\u308b\u3053\u3068\u3067\u7279\u5fb4\u4ed8\u3051\u3089\u308c\u307e\u3059\uff08\u56f35.1\uff09\u3002SOX1\u306f\u3001\u521d\u671f\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u65b0\u751f\u306e\u5f15\u304d\u91d1\u3068\u306a\u308a\u3001NSC\u3092\u672a\u5206\u5316\u72b6\u614b\u306b\u7dad\u6301\u3059\u308b\u6a5f\u80fd\u304c\u3042\u308a\u307e\u3059\u3002SOX2\u306f\u3001\u30ad\u30fc\u8ee2\u5199\u56e0\u5b50\u3067\u3001PSC\u304a\u3088\u3073NSC\u306e\u81ea\u5df1\u8907\u88fd\u7279\u6027\u3092\u7dad\u6301\u3057\u307e\u3059\u3002PAX6\u306f\u3001\u30cb\u30e5\u30fc\u30ed\u30f3\u65b0\u751f\u521d\u671f\u306b\u795e\u7d4c\u5916\u80da\u8449\u30de\u30fc\u30ab\u30fc\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002NSC\u306f\u4e00\u5ea6\u6a39\u7acb\u3055\u308c\u308b\u3068\u3001PAX6\u3092\u767a\u73fe\u3057\u7d9a\u3051\u3066\u3082\u3001\u305d\u306e\u7d30\u80de\u904b\u547d\u306f\u7279\u5b9a\u306e\u795e\u7d4c\u30b5\u30d6\u30bf\u30a4\u30d7\u306b\u9650\u5b9a\u3055\u308c\u307e\u3059<sup>*3<\/sup>\u3002\u30cd\u30b9\u30c1\u30f3\u3082\u3001CNS\u306e\u767a\u9054\u521d\u671f\u306e\u9593\u306b\u767a\u73fe\u3057\u307e\u3059\u304c\u3001NSC\u304c\u5206\u5316\u3057\u3001\u6210\u719f\u30cb\u30e5\u30fc\u30ed\u30f3\u3084\u30b0\u30ea\u30a2\u7d30\u80de\u306b\u306a\u308b\u3068\u6d88\u5931\u3057\u307e\u3059\u3002<br \/>\n\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u5206\u5316\u4e2d\u3001NSC\u306f\u9032\u884c\u6027\u306e\u7d30\u80de\u7cfb\u8b5c\u306e\u5236\u9650\u3092\u53d7\u3051\uff08\u56f35.2\uff09\u3001\u30b0\u30ea\u30a2\u524d\u99c6\u7d30\u80de\uff08CD44+\/A2B5+\uff09\u304c\u5f62\u6210\u3055\u308c\u3001\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\uff08GFAP+\uff09\uff08\u56f35.3\uff09\u304a\u3088\u3073\u30aa\u30ea\u30b4\u30c7\u30f3\u30c9\u30ed\u30b5\u30a4\u30c8\uff08Galc+\u304a\u3088\u3073O4+\uff09\u3068\u306a\u308a\u307e\u3059\u3002\u7d30\u80de\u7cfb\u8b5c\u306e\u5236\u9650\u306b\u304a\u3051\u308b\u4ed6\u306e\u5206\u5c90\u306b\u306f\u3001\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\uff08DA\uff09\u30cb\u30e5\u30fc\u30ed\u30f3\uff08\u56f35.5\uff09\u3001GABA\u4f5c\u52d5\u6027\uff08GABA\uff09\u30cb\u30e5\u30fc\u30ed\u30f3\uff08\u56f35.6\uff09\u3001\u304a\u3088\u3073\u904b\u52d5\u30cb\u30e5\u30fc\u30ed\u30f3\u306a\u3069\u306e\u69d8\u3005\u306a\u30bf\u30a4\u30d7\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\uff08\u56f35.4\uff09\u306e\u5f62\u6210\u306b\u3064\u306a\u304c\u308b\u795e\u7d4c\u7cfb\u7d71\u306e\u7d4c\u8def\u304c\u3042\u308a\u307e\u3059\u3002NSC\u306e\u5358\u96e2\u6cd5\u3001PSC\u304b\u3089\u306eNSC\u306e\u8a98\u5c0e\u6cd5\u3001\u304a\u3088\u3073 in vitro \u3067\u306e\u5897\u6b96\u6cd5\u306e\u958b\u767a\u306b\u304a\u3051\u308b\u9032\u6b69\u306f\u3001NSC\u3092\u57fa\u790e\u7684\u306a\u767a\u9054\u7814\u7a76\u3084\u7d30\u80de\u7642\u6cd5\u306e\u305f\u3081\u306e\u6709\u671b\u306a\u30c4\u30fc\u30eb\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u3068\u3057\u307e\u3057\u305f<sup>*2<\/sup>\u3002<br \/>\nPSC\u304b\u3089DA\u30cb\u30e5\u30fc\u30ed\u30f3\u306a\u3069\u306e\u7279\u5b9a\u306e\u795e\u7d4c\u7d30\u80de\u30b5\u30d6\u30bf\u30a4\u30d7\u306b\u76f4\u63a5\u8a98\u5c0e\u3059\u308b\u305f\u3081\u306e\u69d8\u3005\u306a\u5206\u5316\u8a98\u5c0e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3082\u958b\u767a\u3055\u308c\u3066\u304d\u3066\u3044\u307e\u3059<sup>*4<\/sup>\u3002 \u3053\u308c\u3089\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3001\u7814\u7a76\u5bfe\u8c61\u306e\u75be\u60a3\u306b\u95a2\u9023\u3059\u308b\u7279\u5b9a\u306e\u30bf\u30a4\u30d7\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u751f\u6210\u3092\u53ef\u80fd\u3068\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10091 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-2.jpg\" alt=\"\" width=\"397\" height=\"801\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-2.jpg 397w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig3-2-149x300.jpg 149w\" sizes=\"auto, (max-width: 397px) 100vw, 397px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10085 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-2.jpg\" alt=\"\" width=\"404\" height=\"867\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-2.jpg 404w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig4-2-140x300.jpg 140w\" sizes=\"auto, (max-width: 404px) 100vw, 404px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10086 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-2.jpg\" alt=\"\" width=\"400\" height=\"926\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-2.jpg 400w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig5-2-130x300.jpg 130w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10087 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-2.jpg\" alt=\"\" width=\"769\" height=\"934\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-2.jpg 769w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig6-2-247x300.jpg 247w\" sizes=\"auto, (max-width: 769px) 100vw, 769px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10088 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-2.jpg\" alt=\"\" width=\"398\" height=\"433\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-2.jpg 398w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/Fig7-2-276x300.jpg 276w\" sizes=\"auto, (max-width: 398px) 100vw, 398px\" \/><br \/>\n\u795e\u7d4c\u969c\u5bb3\u306b\u304a\u3051\u308b\u5e79\u7d30\u80de\u306e\u4f7f\u7528\u306b\u5bfe\u3059\u308b\u9700\u8981\u306f\u9ad8\u307e\u3063\u3066\u3044\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u5bfe\u51e6\u3059\u3079\u304d\u91cd\u8981\u306a\u8ab2\u984c\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u9ad8\u54c1\u8cea\u306e\u795e\u7d4c\u30b5\u30d6\u30bf\u30a4\u30d7\u3092\u4e00\u8cab\u3057\u3066\u7523\u751f\u3059\u308b\u3088\u3046\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30b7\u30b9\u30c6\u30e0\u304c\u5fc5\u8981\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002NSC\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u3092\u901a\u3057\u3066\u3001\u795e\u7d4c\u30d1\u30bf\u30fc\u30f3\u5f62\u6210\u304a\u3088\u3073\u4e2d\u67a2\u795e\u7d4c\u7cfb\u306b\u5bc4\u4e0e\u3059\u308b3\u3064\u306e\u4e3b\u8981\u306a\u7d30\u80de\u30bf\u30a4\u30d7\uff08\u3059\u306a\u308f\u3061\u3001\u30cb\u30e5\u30fc\u30ed\u30f3\u3001\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u3001\u304a\u3088\u3073\u30aa\u30ea\u30b4\u30c7\u30f3\u30c9\u30ed\u30b5\u30a4\u30c8\uff09\u306e\u5f62\u6210\uff08\u88685.1\uff09\u3001\u306a\u3089\u3073\u306b\u305d\u308c\u3089\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u5fae\u5c0f\u74b0\u5883\u306b\u5bfe\u3059\u308b\u7406\u89e3\u3092\u6df1\u3081\u308b\u3053\u3068\u306f\u3001\u81e8\u5e8a\u7684\u6210\u529f\u306e\u53ef\u80fd\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u306e\u306b\u6975\u3081\u3066\u91cd\u8981\u3067\u3059<sup>*1<\/sup>\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u5e79\u7d30\u80de\u7814\u7a76\u7528\u6297\u4f53\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u672c\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u5e79\u7d30\u80de\u7814\u7a76\u306b\u95a2\u3059\u308b\u6df1\u3044\u77e5\u8b58\u306e\u7fd2\u5f97\u3001\u304a\u3088\u3073\u6700\u65b0\u306e\u7814\u7a76\u306b\u5f79\u7acb\u3064\u6297\u4f53\u95a2\u9023\u88fd\u54c1\u306e\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/en\/home\/global\/forms\/antibody-stem-cell-guidebook-form.html?CID=bid_pca_aup_r04_jp_cp1435_pjt7391_bid00000_0so_blg_op_lgn_kt_s00_stem4_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p><strong>\u53c2\u8003\u6587\u732e:<\/strong><br \/>\n1. Ichida JK, Kiskinis E (2015) Probing disorders of the nervous system using reprogramming approaches. EMBOJ 34(11):1456\u20131477.<br \/>\n2. Gage FH, Temple S (2013) Neural stem cells: generating and regenerating the brain. Neuron 80(3):588\u2013601.<br \/>\n3. Zhang X, Huang CT, Chen J et al. (2010) Pax6 is a human neuroectoderm cell fate determinant. Cell Stem Cell 7(1):90\u2013100.<br \/>\n4. Kriks S, Shim JW, Piao J et al. (2011) Dopamine neurons derived from human ES cells efficiently engraft in animal models of Parkinson\u2019s disease. Nature 480(7378):547\u2013551.<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306e\u91cd\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e00\u3064\u306b\u7d30\u80de\u7642\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6162\u6027\u809d\u75be\u60a3\u3001\u7cd6\u5c3f\u75c5\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u6cbb\u7642\u7814\u7a76\u306b\u6d3b\u7528\u3067\u304d\u308b\u3001PSC\u304a\u3088\u3073\u305d\u306e\u5206\u5316\u8a98\u5c0e\u4f53\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057<\/p>\n","protected":false},"author":975,"featured_media":10097,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-10084","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316\" \/>\n<meta property=\"og:description\" content=\"\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306e\u91cd\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e00\u3064\u306b\u7d30\u80de\u7642\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6162\u6027\u809d\u75be\u60a3\u3001\u7cd6\u5c3f\u75c5\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u6cbb\u7642\u7814\u7a76\u306b\u6d3b\u7528\u3067\u304d\u308b\u3001PSC\u304a\u3088\u3073\u305d\u306e\u5206\u5316\u8a98\u5c0e\u4f53\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-29T07:18:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T07:22:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1575\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316\",\"datePublished\":\"2021-09-29T07:18:45+00:00\",\"dateModified\":\"2025-04-01T07:22:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/\"},\"wordCount\":164,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/\",\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"datePublished\":\"2021-09-29T07:18:45+00:00\",\"dateModified\":\"2025-04-01T07:22:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/09\\\/shutterstock_1086033461-scaled.jpg\",\"width\":2560,\"height\":1575},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/antibody_characterization_pca_bid_ts_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316","og_description":"\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08PSC\uff09\u306e\u91cd\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u4e00\u3064\u306b\u7d30\u80de\u7642\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6162\u6027\u809d\u75be\u60a3\u3001\u7cd6\u5c3f\u75c5\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u6cbb\u7642\u7814\u7a76\u306b\u6d3b\u7528\u3067\u304d\u308b\u3001PSC\u304a\u3088\u3073\u305d\u306e\u5206\u5316\u8a98\u5c0e\u4f53\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-09-29T07:18:45+00:00","article_modified_time":"2025-04-01T07:22:50+00:00","og_image":[{"width":2560,"height":1575,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316","datePublished":"2021-09-29T07:18:45+00:00","dateModified":"2025-04-01T07:22:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/"},"wordCount":164,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/","name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","datePublished":"2021-09-29T07:18:45+00:00","dateModified":"2025-04-01T07:22:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","width":2560,"height":1575},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody_characterization_pca_bid_ts_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6297\u4f53\u6cd5\u306b\u3088\u308b\u5e79\u7d30\u80de\u30ad\u30e3\u30e9\u30af\u30bf\u30ea\u30bc\u30fc\u30b7\u30e7\u30f3\u8b1b\u5ea73\u3000\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u5206\u5316"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-1024x630.jpg",760,468,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":10084,"position":0},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":10084,"position":1},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":10084,"position":2},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":10084,"position":3},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":10084,"position":4},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":10084,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/09\/shutterstock_1086033461-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10084","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=10084"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10084\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10097"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=10084"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=10084"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=10084"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=10084"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}