{"id":10495,"date":"2021-12-10T15:31:54","date_gmt":"2021-12-10T06:31:54","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=10495"},"modified":"2021-12-21T21:35:18","modified_gmt":"2021-12-21T12:35:18","slug":"edge_effect_reduction_ccp_lpe_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/","title":{"rendered":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates"},"content":{"rendered":"<p>\u30a8\u30c3\u30b8\u52b9\u679c\u3068\u306f\u7d30\u80de\u57f9\u990a\u4e2d\u306b96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e\u3001\u7279\u306b\u5916\u5468\u30a6\u30a7\u30eb\u306e\u57f9\u5730\u91cf\u304c\u6e1b\u5c11\u3057\u3001\u30a6\u30a7\u30eb\u5185\u306b\u304a\u3051\u308b\u7d30\u80de\u72b6\u614b\u3084\u5897\u6b96\u306e\u60aa\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u73fe\u8c61\u3067\u3059\u3002\u539f\u56e0\u306f\u57f9\u5730\u306e\u84b8\u767a\u3067\u3059\u304c\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u306b\u3088\u308a\u5185\u5074\u30a6\u30a7\u30eb\u3068\u5916\u5468\u30a6\u30a7\u30eb\u306e\u9593\u306b\u30c7\u30fc\u30bf\u306b\u5dee\u304c\u751f\u3058\u308b\u305f\u3081\u306b\u5916\u5468\u30a6\u30a7\u30eb\u4ee5\u5916\u306e60\u30a6\u30a7\u30eb\u306e\u307f\u306e\u4f7f\u7528\u3092\u5f37\u3044\u3089\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u30b3\u30b9\u30c8\u30a2\u30c3\u30d7\u3084\u4f5c\u696d\u306e\u5897\u52a0\u306b\u3064\u306a\u304c\u3063\u3066\u3057\u307e\u3044\u307e\u3059\u3002<br \/>\n\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u6291\u5236\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\uff1a\u4f4e\u84b8\u767a\u306e\u305f\u3081\u3001\u9577\u671f\u30bf\u30a4\u30e0\u30e9\u30d7\u30b9\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306b\u6700\u9069<br \/>\n\u30fb\u30ed\u30dc\u30c3\u30c8\u30b7\u30b9\u30c6\u30e0\uff1a\u6db2\u4f53\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0\u30c7\u30d0\u30a4\u30b9\u3084\u30c7\u30fc\u30bf\u51e6\u7406\u3092\u7528\u3044\u305f\u81ea\u52d5\u5316\u306b\u3082\u5bfe\u5fdc<br \/>\n\u30fb\u7d30\u80de\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\uff1a\u4f4e\u84b8\u767a\u306e\u305f\u3081\u3001\u9650\u754c\u5e0c\u91c8\u57f9\u990a\u3084\u5c11\u5bb9\u91cf\u57f9\u990a\u304c\u53ef\u80fd\u306b\u306a\u308a\u6297\u4f53\u4fa1\u304c\u5b89\u5b9a<\/p>\n<h2>\u30a8\u30c3\u30b8\u52b9\u679c\u3068\u306f<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10501 alignright\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2.png\" alt=\"\" width=\"293\" height=\"226\" \/><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10500 alignright\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/1.png\" alt=\"\" width=\"294\" height=\"227\" \/>\u30a8\u30c3\u30b8\u52b9\u679c\u306e\u539f\u56e0\u306fCO<sub>2<\/sub>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u5185\u306e\u5faa\u74b0\u30a8\u30a2\u3078\u306e\u66b4\u9732\u306b\u3088\u308b\u57f9\u5730\u306e\u84b8\u767a\u3067\u3059\u304c\u3001\u3053\u306e\u73fe\u8c61\u306b\u3088\u308b\u57f9\u5730\u6210\u5206\u306e\u6fc3\u5ea6\u4e0a\u6607\u3084\u5916\u5468\u30a6\u30a7\u30eb\u306epH\u306e\u5909\u5316\u306b\u3088\u3063\u3066\u57f9\u990a\u7d30\u80de\u3078\u306e\u30b9\u30c8\u30ec\u30b9\u3084\u30c0\u30e1\u30fc\u30b8\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u307e\u3059\u3002\u4eca\u307e\u3067\u306f\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u56de\u907f\u3059\u308b\u305f\u3081\u306b\u5916\u5468\u306e\u30a6\u30a7\u30eb\u4e00\u5217\u306b\u6ec5\u83cc\u6c34\u3084PBS\u3092\u5165\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u3053\u308c\u306f\u5916\u5468\u4e00\u521736\u30a6\u30a7\u30eb\u306e\u30ed\u30b9\uff1d\u7d042\/3\u306e\u30a6\u30a7\u30eb\u3057\u304b\u4f7f\u7528\u3067\u304d\u306a\u3044\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3067\u304d\u308b\u88fd\u54c1\u304c\u30a8\u30c3\u30b8\u30d7\u30ec\u30fc\u30c8\u3067\u3059\u3002\u4f7f\u7528\u6cd5\u306f\u975e\u5e38\u306b\u7c21\u4fbf\u3067\u3001\u30d7\u30ec\u30fc\u30c8\u306e\u5468\u8fba\u306b\u3042\u308b4\u304b\u6240\u306e\u30e2\u30fc\u30c8\u90e8\u306b1.7 mL\u306e\u6ec5\u83cc\u6c34\u3084PBS\u3092\u5165\u308c\u308b\u3060\u3051\u3067\u3059\u3002<\/p>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2><\/h2>\n<h2><span id=\"product-name\">Edge 2.0 96-well Plate\u3068\u4ed6\u88fd\u54c1\u306e\u84b8\u767a\u91cf\uff0f\u7d30\u80de\u751f\u5b58\u7387\u306e\u6bd4\u8f03<\/span><\/h2>\n<p><strong>Edge 2.0 96-well Plate\u306f\u5468\u8fba\u306e\u30e2\u30fc\u30c8\u90e8\u306b\u3088\u308a\u3001\u901a\u5e38\u306e96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306b\u898b\u3089\u308c\u308b\u5916\u5468\u30a6\u30a7\u30eb\u306e\u84b8\u767a\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u5927\u5e45\u306b\u4f4e\u6e1b\u3055\u305b\u3066\u3044\u307e\u3059\u3002<br \/>\n<\/strong><\/p>\n<p>\u5404\u30a6\u30a7\u30eb\u306b\u304a\u3051\u308b\u84b8\u767a\u91cf\u6bd4\u8f03<br \/>\n\u3010\u5b9f\u9a13\u65b9\u6cd5\u3011<br \/>\n1. \u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u306e\u524d\u306bEdge 2.0 96-well Plate\u306e4\u30ab\u6240\u306e\u30e2\u30fc\u30c8\u90e8\u306b1.7 mL\u305a\u3064\u306e\u6ec5\u83cc\u6c34\u3092\u5165\u308c\u307e\u3057\u305f\u3002<br \/>\n2. Edge 2.0 96-well Plate\u3068\u901a\u5e38\u306e96\u30de\u30a4\u30af\u30ed\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e0.1%\u30e1\u30c1\u30eb\u30d0\u30a4\u30aa\u30ec\u30c3\u30c8\u6eb6\u6db2\u3092100 \u03bcL\/\u30a6\u30a7\u30eb\u5206\u6ce8\u3057\u307e\u3057\u305f\u3002<br \/>\n3. \u3059\u3079\u3066\u306e\u30d7\u30ec\u30fc\u30c8\u309237\u2103\u30674\u65e5\u9593\u3001CO\u2082\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u5185\u3067\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3057\u307e\u3057\u305f\u3002\u9014\u4e2d\u3001\u5b9f\u969b\u306e\u4f7f\u7528\u6761\u4ef6\u3092\u518d\u73fe\u3059\u308b\u305f\u3081\u306b1\u6642\u9593\u3054\u3068\u306b15\u79d2\u9593\u30011\u65e5\u8a087\u56de\u3001CO\u2082\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u306e\u30c9\u30a2\u3092\u958b\u3051\u307e\u3057\u305f\u3002<br \/>\n4. \u30d7\u30ec\u30fc\u30c8\u306e\u5168\u84b8\u767a\u91cf\u306f\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u306e\u524d\u5f8c\u306e\u91cd\u91cf\u306e\u5dee\u306b\u3088\u3063\u3066\u5224\u5b9a\u3057\u307e\u3057\u305f\u3002\u5404\u3005\u306e\u30a6\u30a7\u30eb\u306e\u84b8\u767a\u91cf\u306f\u5404\u30a6\u30a7\u30eb\u304b\u308950 \u03bcL\u306e\u30e1\u30c1\u30eb\u30d0\u30a4\u30aa\u30ec\u30c3\u30c8\u6eb6\u6db2\u309296\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306b\u79fb\u3057\u3001590 nm\u3067\u5438\u5149\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u5224\u5b9a\u3057\u307e\u3057\u305f\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-10506\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_24-1024x252.png\" alt=\"\" width=\"760\" height=\"187\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_24-1024x252.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_24-300x74.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_24-768x189.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_24.png 1294w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p><strong>\u7d30\u80de\u751f\u5b58\u7387\u306e\u30d0\u30e9\u3064\u304d\u306f\u901a\u5e38\u30d7\u30ec\u30fc\u30c8\uff08Brand N\u3084C\uff09\u3068\u6bd4\u8f03\u3057\u3066\u5468\u8fba\u30e2\u30fc\u30c8\u90e8\u306e\u3042\u308bEdge 2.0 96-well Plate\u3067\u6700\u5c0f\u9650\u307e\u3067\u4f4e\u6e1b\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<p>\u7d30\u80de\u751f\u5b58\u7387<br \/>\n\u3010\u5b9f\u9a13\u65b9\u6cd5\u3011<br \/>\n1. \u30d2\u30c8carcinoma\u7531\u6765549\u7d30\u80de\uff089,000 cells\/mL\u3001100 \u03bcL\/\u30a6\u30a7\u30eb\uff09\u309210%FBS\u30011%\u30da\u30cb\u30b7\u30ea\u30f3-\u30b9\u30c8\u30ec\u30d7\u30c8\u30de\u30a4\u30b7\u30f3\u30012 mM\u306eL-\u30b0\u30eb\u30bf\u30df\u30f3\u3092\u542b\u3080DMEM\u57f9\u5730\u3067\u57f9\u990a\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u6642\u306bEdge 2.0 96-well Plate\u306e\u30e2\u30fc\u30c8\u90e8\u306b\u306f\u6ec5\u83cc\u6c34\u3092\u6e80\u305f\u3057\u307e\u3057\u305f\u3002<br \/>\n2. 37\u2103\u306eCO\u2082\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u30674\u65e5\u9593\u57f9\u990a\u3057\u305f\u5f8c\u306bA549\u7d30\u80de\u306e\u751f\u5b58\u7387\u3092AlamarBlue\u30a2\u30c3\u30bb\u30a4\u306b\u3088\u3063\u3066\u5224\u5b9a\u3057\u307e\u3057\u305f\u3002\u5404\u3005\u306e\u30a6\u30a7\u30eb\u306e\u7d30\u80de\u751f\u5b58\u7387\u306e\u30d0\u30e9\u3064\u304d\u306f\u30d1\u30fc\u30bb\u30f3\u30c8\u8a08\u7b97\u3057\u307e\u3059\u306e\u5206\u6563\u306b\u3088\u3063\u3066\u8a08\u7b97\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-10510\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_59-1024x268.png\" alt=\"\" width=\"760\" height=\"199\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_59-1024x268.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_59-300x78.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_59-768x201.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/2021-12-02_13h46_59.png 1300w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<h2>\u591a\u5f69\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u4f8b<\/h2>\n<p><strong>96\u30a6\u30a7\u30eb\u3059\u3079\u3066\u3092\u6709\u52b9\u306b\u4f7f\u7528\u3067\u304d\u3001\u5168\u30a6\u30a7\u30eb\u306e\u6e2c\u5b9a\u5024\u3092\u7cbe\u5ea6\u9ad8\u304f\u8a55\u4fa1\u3067\u304d\u307e\u3059\u3002<\/strong><br \/>\n\u30fb\u7d30\u80de\u30b7\u30b0\u30ca\u30eb\u3068\u8ee2\u5199\u56e0\u5b50\uff1a\u7d30\u80de\u30b7\u30b0\u30ca\u30ea\u30f3\u30b0\u3084\u8ee2\u5199\u56e0\u5b50\u306e\u6d3b\u6027\u5316\u3001\u79fb\u884c\u3001\u6975\u6027\u306e\u89e3\u6790<br \/>\n\u30fb\u7d30\u80de\u5468\u671f\u3068\u7d30\u80de\u5897\u6b96\uff1a\u7d30\u80de\u5468\u671f\u3084\u5897\u6b96\u6bb5\u968e\u306e\u89e3\u6790<br \/>\n\u30fb\u7d30\u80de\u6bd2\u6027\u3068\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\uff1a\u7d30\u80de\u6bd2\u6027\u3084\u7d30\u80de\u6b7b\u306e\u89e3\u6790\u304a\u3088\u3073\u95a2\u9023\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u89e3\u6790<br \/>\n\u30fb\u708e\u75c7\u3068\u7d30\u80de\u30b9\u30c8\u30ec\u30b9\uff1a\u708e\u75c7\u3084\u7d30\u80de\u30b9\u30c8\u30ec\u30b9\u306b\u95a2\u9023\u3057\u305f\u30de\u30fc\u30ab\u30fc\u3084\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u89e3\u6790<br \/>\n\u30fb\u7d30\u80de\u5f62\u614b\u3068\u5f62\u614b\u5909\u5316\uff1a\u7d30\u80de\u9aa8\u683c\u3084\u4ed6\u306e\u7d30\u80de\u5f62\u614b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u89e3\u6790<br \/>\n\u30fb\u907a\u4f1d\u5b50\u6bd2\u6027\u3068DNA\u640d\u50b7\uff0f\u4fee\u5fa9\uff1a\u67d3\u8272\u4f53\u306e\u4e0d\u5b89\u5b9a\u6027\u3084DNA\u640d\u50b7\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u89e3\u6790<br \/>\n\u30fb\u7d30\u80de\u904a\u8d70\u3068\u7d30\u80de\u904b\u52d5\uff1a\u7d30\u80de\u904a\u8d70\u3068\u7d30\u80de\u904b\u52d5\u306e\u89e3\u6790<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p><strong>Edge 2.0 96-well Plate\u306e\u7279\u9577<br \/>\n\u30fb<\/strong>\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u6291\u5236\u3059\u308b\u3053\u3068\u306b\u3088\u308a96\u30a6\u30a7\u30eb\u3059\u3079\u3066\u3092\u6709\u52b9\u306b\u4f7f\u7528\u3067\u304d\u3001\u5168\u30a6\u30a7\u30eb\u306e\u6e2c\u5b9a\u5024\u3092\u6b63\u78ba\u306b\u8a55\u4fa1\u3067\u304d\u308b<br \/>\n\u30fbNunclon Delta\u51e6\u7406\u306b\u3088\u308a\u7d30\u80de\u63a5\u7740\u6027\u30fb\u5897\u6b96\u6027\u3092\u4fc3\u9032\uff08\u7d30\u80de\u57f9\u990a\u7528\uff09<br \/>\n\u30fbANSI\/SBS\u56fd\u969b\u6a19\u6e96\u57fa\u6e96\u306b\u6e96\u62e0<br \/>\n\u30fb\u6ec5\u83cc\u4fdd\u8a3c\u30ec\u30d9\u30eb SAL10-6<\/p>\n<p>\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Edge 2.0 96-well Plate\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/cell-culture-plastics\/cell-culture-plates\/96-well-cell-culture-plates\/nunc-edge-96-well-cell-culture-plates.html?cid=Social_LAB\" target=\"_blank\" rel=\"noopener\">\u88fd\u54c1\u30da\u30fc\u30b8<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a8\u30c3\u30b8\u52b9\u679c\u3068\u306f\u7d30\u80de\u57f9\u990a\u4e2d\u306b96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e\u3001\u7279\u306b\u5916\u5468\u30a6\u30a7\u30eb\u306e\u57f9\u5730\u91cf\u304c\u6e1b\u5c11\u3057\u3001\u30a6\u30a7\u30eb\u5185\u306b\u304a\u3051\u308b\u7d30\u80de\u72b6\u614b\u3084\u5897\u6b96\u306e\u60aa\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u73fe\u8c61\u3067\u3059\u3002\u539f\u56e0\u306f\u57f9\u5730\u306e\u84b8\u767a\u3067\u3059\u304c\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u306b\u3088\u308a\u5185\u5074\u30a6\u30a7\u30eb\u3068\u5916\u5468\u30a6\u30a7\u30eb\u306e\u9593\u306b\u30c7\u30fc\u30bf\u306b\u5dee\u304c\u751f<\/p>\n","protected":false},"author":975,"featured_media":10705,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":["post-10495","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates\" \/>\n<meta property=\"og:description\" content=\"\u30a8\u30c3\u30b8\u52b9\u679c\u3068\u306f\u7d30\u80de\u57f9\u990a\u4e2d\u306b96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e\u3001\u7279\u306b\u5916\u5468\u30a6\u30a7\u30eb\u306e\u57f9\u5730\u91cf\u304c\u6e1b\u5c11\u3057\u3001\u30a6\u30a7\u30eb\u5185\u306b\u304a\u3051\u308b\u7d30\u80de\u72b6\u614b\u3084\u5897\u6b96\u306e\u60aa\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u73fe\u8c61\u3067\u3059\u3002\u539f\u56e0\u306f\u57f9\u5730\u306e\u84b8\u767a\u3067\u3059\u304c\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u306b\u3088\u308a\u5185\u5074\u30a6\u30a7\u30eb\u3068\u5916\u5468\u30a6\u30a7\u30eb\u306e\u9593\u306b\u30c7\u30fc\u30bf\u306b\u5dee\u304c\u751f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-10T06:31:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-21T12:35:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"310\" \/>\n\t<meta property=\"og:image:height\" content=\"140\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates\",\"datePublished\":\"2021-12-10T06:31:54+00:00\",\"dateModified\":\"2021-12-21T12:35:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/\"},\"wordCount\":66,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/12\\\/Blog-Hero-banner-template-310-x-140.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/\",\"name\":\"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/12\\\/Blog-Hero-banner-template-310-x-140.jpg\",\"datePublished\":\"2021-12-10T06:31:54+00:00\",\"dateModified\":\"2021-12-21T12:35:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/12\\\/Blog-Hero-banner-template-310-x-140.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/12\\\/Blog-Hero-banner-template-310-x-140.jpg\",\"width\":310,\"height\":140},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/edge_effect_reduction_ccp_lpe_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates","og_description":"\u30a8\u30c3\u30b8\u52b9\u679c\u3068\u306f\u7d30\u80de\u57f9\u990a\u4e2d\u306b96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e\u3001\u7279\u306b\u5916\u5468\u30a6\u30a7\u30eb\u306e\u57f9\u5730\u91cf\u304c\u6e1b\u5c11\u3057\u3001\u30a6\u30a7\u30eb\u5185\u306b\u304a\u3051\u308b\u7d30\u80de\u72b6\u614b\u3084\u5897\u6b96\u306e\u60aa\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u73fe\u8c61\u3067\u3059\u3002\u539f\u56e0\u306f\u57f9\u5730\u306e\u84b8\u767a\u3067\u3059\u304c\u3001\u30a8\u30c3\u30b8\u52b9\u679c\u306b\u3088\u308a\u5185\u5074\u30a6\u30a7\u30eb\u3068\u5916\u5468\u30a6\u30a7\u30eb\u306e\u9593\u306b\u30c7\u30fc\u30bf\u306b\u5dee\u304c\u751f","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2021-12-10T06:31:54+00:00","article_modified_time":"2021-12-21T12:35:18+00:00","og_image":[{"width":310,"height":140,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"2\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates","datePublished":"2021-12-10T06:31:54+00:00","dateModified":"2021-12-21T12:35:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/"},"wordCount":66,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/","name":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","datePublished":"2021-12-10T06:31:54+00:00","dateModified":"2021-12-21T12:35:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","width":310,"height":140},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/edge_effect_reduction_ccp_lpe_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u6700\u9069\uff01\u30a8\u30c3\u30b8\u52b9\u679c\u3092\u8efd\u6e1b\u3067\u304d\u308bNunc Edge 2.0 96-Well Plates"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg",310,140,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":10495,"position":0},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":10495,"position":1},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":10495,"position":2},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20129,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25016\/","url_meta":{"origin":10495,"position":3},"title":"\u3010\u7b2c2\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce","author":"LatB Staff","date":"2026\u5e744\u670828\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u64cd\u4f5c\u3067\u5f79\u7acb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u56de\u53ce\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0f\u80de\u4f53\u30b5\u30a4\u30ba","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/251d14a615127ecd8e0dac1beeb32074.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":25723,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26031\/","url_meta":{"origin":10495,"position":4},"title":"\u3010\u7b2c4\u56de\u3011CHO\u7d30\u80de\u682a\u958b\u767a\u3092\u3088\u308a\u8fc5\u901f\u306b\u2015\u9ad8\u751f\u7523\u6027\u30fb\u9577\u671f\u5b89\u5b9a\u6027\u30fb\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3092\u8a55\u4fa1\u3057\u305fCHOvantage GS CLD Kit","author":"LatB Staff","date":"2026\u5e7411\u67086\u65e5","format":false,"excerpt":"\u6297\u4f53\u533b\u85ac\u54c1\u306e\u958b\u767a\u3067\u306f\u3001\u76ee\u7684\u306e\u6297\u4f53\u3092\u300c\u305f\u304f\u3055\u3093\u4f5c\u308c\u308b\u300d\u7d30\u80de\u3092\u898b\u3064\u3051\u308b\u3060\u3051\u3067\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u9ad8\u3044\u751f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25510,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26022\/","url_meta":{"origin":10495,"position":5},"title":"\u3010\u7b2c1\u56de\u3011\u533b\u85ac\u54c1\u88fd\u9020\u73fe\u5834\u3067\u9846\u7c92\u72b6\u30e1\u30c7\u30a3\u30a2\u304c\u9078\u3070\u308c\u308b\u7406\u7531","author":"LatB Staff","date":"2026\u5e748\u67084\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u57f9\u5730\u3001\u539f\u6599\u3001\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u306b\u95a2\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u8a71\u984c\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002\u7b2c1\u56de\u306f\u3001\u9846\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/07\/cell-culture-basic-cell-culture-bpg-26022_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/07\/cell-culture-basic-cell-culture-bpg-26022_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/07\/cell-culture-basic-cell-culture-bpg-26022_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/07\/cell-culture-basic-cell-culture-bpg-26022_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/12\/Blog-Hero-banner-template-310-x-140.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=10495"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/10495\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10705"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=10495"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=10495"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=10495"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=10495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}