{"id":1097,"date":"2018-12-20T00:00:00","date_gmt":"2018-12-20T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/"},"modified":"2025-02-28T11:09:22","modified_gmt":"2025-02-28T02:09:22","slug":"neuro_disease2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/","title":{"rendered":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064"},"content":{"rendered":"\n<h2>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f<\/h2>\n<p>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u306f\u3001\u8a18\u61b6\u304a\u3088\u3073\u884c\u52d5\u306b\u304a\u3051\u308b\u9032\u884c\u6027\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0<sup>*1,2<\/sup> \u3002\u3053\u308c\u306f\u8a8d\u77e5\u75c7\u306e\u4e2d\u3067\u6700\u3082\u591a\u304f\u307f\u3089\u308c\u308b\u5f62\u614b\u3067\u3001\u767a\u75c5\u306f\u4e00\u822c\u7684\u306b\u5b64\u767a\u6027\u3067\u3001\u975e\u5e38\u306b\u591a\u304f\u306e\u74b0\u5883\u7684\u304a\u3088\u3073\u907a\u4f1d\u7684\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc\u304c\u95a2\u4e0e\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*3,4<\/sup>\u3002<br \/>\n\u30b3\u30ea\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u969c\u5bb3\u304a\u3088\u3073\u5927\u8133\u76ae\u8cea\u306b\u304a\u3051\u308b\u795e\u7d4c\u4f1d\u9054\u306e\u4f4e\u4e0b\u304c\u8a8d\u77e5\u6a5f\u80fd\u306e\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u672c\u75be\u60a3\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u30d7\u30e9\u30fc\u30af\uff08\u30a2\u30df\u30ed\u30a4\u30c9\u306e\u7d30\u80de\u5916\u795e\u7d4c\u7d44\u7e54\u3078\u306e\u6c88\u7740\uff09\u3001\u304a\u3088\u3073\u30ea\u30f3\u9178\u5316\u3057\u305f\u30bf\u30a6\u30bf\u30f3\u30d1\u30af\u8cea\u304b\u3089\u69cb\u6210\u3055\u308c\u308b\u7d30\u80de\u5185\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306e\u5b58\u5728\u306b\u3088\u3063\u3066\u7279\u5fb4\u4ed8\u3051\u3089\u308c\u307e\u3059\u00a0<sup>*5\u00a0<\/sup>\u3002 \u81e8\u5e8a\u7684\u304a\u3088\u3073\u795e\u7d4c\u75c5\u7406\u5b66\u7684\u75c7\u72b6\u306e\u30a8\u30d3\u30c7\u30f3\u30b9\u306b\u5148\u7acb\u3063\u3066\u3001\u55c5\u5185\u76ae\u8cea\u3001\u6d77\u99ac\u3001\u5f8c\u5e2f\u72b6\u56de\u76ae\u8cea\u3001\u304a\u3088\u3073\u4e2d\u5074\u982d\u56de\u306a\u3069\u306e\u8133\u9818\u57df\u306b\u304a\u3051\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u304a\u3088\u3073\u7d30\u80de\u6a5f\u80fd\u306b\u64b9\u4e71\u304c\u89b3\u5bdf\u3055\u308c\u5f97\u307e\u3059\u00a0<sup>*6<\/sup> \u3002\u7279\u306bAD\u306f\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u306b\u3088\u3063\u3066\u8a98\u767a\u3055\u308c\u308b\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u6a5f\u80fd\u4e0d\u5168\u3001\u91cd\u5ea6\u306e\u9178\u5316\u30b9\u30c8\u30ec\u30b9\u3001DNA\u640d\u50b7\u3001\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3001\u304a\u3088\u3073\u8133\u5185\u30db\u30e1\u30aa\u30b9\u30bf\u30b7\u30b9\u3092\u7834\u58ca\u3057\u3001\u30b7\u30ca\u30d7\u30b9\u6a5f\u80fd\u969c\u5bb3\u3092\u5f15\u304d\u8d77\u3053\u3059\u4ed6\u306e\u58ca\u6ec5\u7684\u306a\u30d7\u30ed\u30bb\u30b9\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0<sup>*7<\/sup>\u3002<br \/>\n\u73fe\u5728\u627f\u8a8d\u6e08\u307f\u306eAD\u6cbb\u7642\u85ac\u306f\u3001\u4e00\u90e8\u306eAD\u7f79\u60a3\u8005\u306e\u75c7\u72b6\u3092\u4e00\u6642\u7684\u306b\u8efd\u6e1b\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u6839\u672c\u7684\u306b\u75be\u60a3\u30d7\u30ed\u30bb\u30b9\u3092\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u00a0<sup>*8<\/sup> \u3002AD\u306e\u65e9\u671f\u767a\u898b\u304a\u3088\u3073\u6839\u672c\u7684\u306a\u6027\u8cea\u3092\u5909\u5316\u3055\u305b\u308b\u6cbb\u7642\u306e\u5fc5\u8981\u6027\u306f\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u767a\u898b\u3001\u8133\u306e\u751f\u4f53\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3001\u795e\u7d4c\u708e\u75c7\u3001\u306a\u3089\u3073\u306b\u5e79\u7d30\u80de\u30d9\u30fc\u30b9\u306e\u7814\u7a76\u30c4\u30fc\u30eb\u304a\u3088\u3073\u6709\u671b\u306a\u6cbb\u7642\u6cd5\u306a\u3069\u306e\u57fa\u790e\u7684\u304a\u3088\u3073\u6a4b\u6e21\u3057\u3068\u306a\u308b\u3088\u3046\u306aAD\u306e\u65b0\u898f\u306a\u7814\u7a76\u5206\u91ce\u306b\u5bfe\u3059\u308b\u7a76\u660e\u306b\u62cd\u8eca\u3092\u639b\u3051\u307e\u3059\u00a0<sup>*9,10<\/sup>\u3002<\/p>\n<p>\u203b<span style=\"text-decoration: underline\">\u672c\u8a18\u4e8b\u306e\u672b\u5c3e\u306b\u304a\u3044\u3066\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u3064\u3044\u3066\u4f53\u7cfb\u7684\u306b\u5b66\u3079\u308b\u7121\u6599\u30b3\u30f3\u30c6\u30f3\u30c4\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059<\/span>\u3002<\/p>\n<h4>\u4e00\u822c\u7d71\u8a08<\/h4>\n<p>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306f\u795e\u7d4c\u5909\u6027\u75be\u60a3\uff08ND\uff09\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u5f62\u614b\u3067\u300165\u6b73\u4ee5\u4e0a\u306e\u4eba\u53e3\u306e10\uff05\u4ee5\u4e0a\u304c\u7f79\u60a3\u3057\u3066\u3044\u308b\u3068\u3055\u308c\u307e\u3059\u00a0<sup>*4<\/sup> \u3002\u30a2\u30e1\u30ea\u30ab\u3067\u306f\u7d045.3\u767e\u4e07\u4eba\u3001\u4e16\u754c\u3067\u306f\u307b\u307c44\u767e\u4e07\u4eba\u304cAD\u3092\u767a\u75c7\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*4,11<\/sup>\u3002 AD\u306e\u767a\u75c7\u304a\u3088\u3073AD\u767a\u75c7\u306e\u30ea\u30b9\u30af\u306f\u5e74\u9f62\u306e\u4e0a\u6607\u3068\u3068\u3082\u306b\u5897\u52a0\u3057\u3001\u5927\u90e8\u5206\u306eAD\u60a3\u8005\uff08\uff1e96\uff05\uff09\u306f65\u6b73\u3092\u8d85\u3048\u3066\u3044\u307e\u3059\uff08\u56f33.1\uff09\u00a0<sup>*4<\/sup> \u3002\u75ab\u5b66\u7684\u8a55\u4fa1\u306b\u304a\u3044\u3066\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306f\u8a8d\u77e5\u75c7\u306e\u5168\u75c7\u4f8b\u306e\u7d0460\uff05\uff5e80\uff05\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u00a0<sup>*12<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-136.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3239 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-136.jpg\" alt=\"\u30a2\u30e1\u30ea\u30ab\u306b\u304a\u3051\u308b\u5e74\u9f62\u5225\u306e\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u7f79\u60a3\u7387\uff082015\uff09\" width=\"379\" height=\"344\" \/><\/a><\/p>\n<h4>\u4e00\u822c\u7684\u306a\u539f\u56e0\u304a\u3088\u3073\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc<\/h4>\n<p>AD\u306e\u5bb6\u65cf\u6b74\u306f\u3001\u500b\u4eba\u306eAD\u767a\u75c7\u306b\u5f71\u97ff\u3059\u308b\u50be\u5411\u304c\u3042\u308a\u3001\u5bb6\u65cf\u306b1\u4eba\u4ee5\u4e0a\u7f79\u60a3\u8005\u304c\u3044\u308b\u5834\u5408\u3001\u767a\u75c7\u30ea\u30b9\u30af\u304c\u4e0a\u6607\u3057\u307e\u3059\u3002\u5e38\u67d3\u8272\u4f53\u512a\u6027AD\uff08ADAD\uff09\u306f\u3001\u5178\u578b\u7684\u306b\u306f60\u6b73\u4ee5\u524d\u306b\u767a\u75c7\u3059\u308b\u65e9\u671f\u767a\u75c7\u578bAD\u3067\u3059\u304c\u3001AD\u75c7\u4f8b\u306e5\uff05\u4ee5\u4e0b\u3068\u3055\u308c\u307e\u3059\u3002ADAD\u306b\u95a2\u4e0e\u3059\u308b\u907a\u4f1d\u5b50\u3068\u3057\u3066\u306f\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP\uff09\u304a\u3088\u3073\u30d7\u30ec\u30bb\u30cb\u30ea\u30f3-1\u304a\u3088\u3073-2\uff08PS-1\u304a\u3088\u3073PS-2\uff09\u3092\u30b3\u30fc\u30c9\u3059\u308b\u907a\u4f1d\u5b50\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u30a2\u30dd\u30ea\u30dd\u30bf\u30f3\u30d1\u30af\u8ceaE4\uff08Apo E4\uff09\u3001\u304a\u3088\u3073\u591a\u304f\u306e\u4ed6\u306e\u907a\u4f1d\u5b50\u5909\u7570\u306f\u3001\u9045\u767a\u6027AD\u3001\u3042\u308b\u3044\u306f\u5b64\u767a\u6027AD\uff08SAD\uff09\u306e\u767a\u75c7\u30ea\u30b9\u30af\u306e\u4e0a\u6607\u306b\u95a2\u4e0e\u3059\u308b\u3068\u3055\u308c\u3001AD\u75c7\u4f8b\u306e\u5927\u90e8\u5206\u3092\u5360\u3081\u3066\u3044\u307e\u3059\u00a0<sup>*13,14<\/sup> \u3002SAD\u306f\u907a\u4f1d\u7684\u8981\u56e0\u304a\u3088\u3073\u74b0\u5883\u8981\u56e0\u306e\u53cc\u65b9\u304c\u95a2\u4e0e\u3057\u3066\u767a\u75c7\u306b\u81f3\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002AD\u306b\u95a2\u4e0e\u3059\u308b\u907a\u4f1d\u5b50\u304a\u3088\u3073\u907a\u4f1d\u5b50\u7523\u7269\u3092\u56f33.2\u304a\u3088\u3073\u88683.1\u306b\u30ea\u30b9\u30c8\u30a2\u30c3\u30d7\u3057\u307e\u3059\u00a0<sup>*15<\/sup>\u3002<\/p>\n<p>AD\u3092\u767a\u75c7\u3055\u305b\u308b\u4e00\u756a\u306e\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc\u306f\u52a0\u9f62\u3067\u3001\u56f33.2\u306b\u793a\u3059\u3088\u3046\u306a\u8133\u840e\u7e2e\u3001\u708e\u75c7\u3001\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u306e\u751f\u6210\u3001\u304a\u3088\u3073\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u6a5f\u80fd\u4e0d\u5168\u306a\u3069\u306e\u5909\u5316\u3092\u8133\u5185\u306b\u751f\u3058\u3055\u305b\u307e\u3059\u3002\u52a0\u9f62\u306f\u3001AD\u306e\u767a\u75c7\u306b\u95a2\u308f\u308b\u6700\u5927\u306e\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc\u3067\u3059\u304c\u3001\u8907\u6570\u306e\u74b0\u5883\u8981\u56e0\u304a\u3088\u3073\u533b\u5b66\u7684\u72b6\u614b\u306b\u3088\u3063\u3066\u30ea\u30b9\u30af\u306f\u5897\u52a0\u3057\u307e\u3059\u3002\u9ad8\u8840\u5727\u3001\u5fc3\u75be\u60a3\u3001\u8133\u5352\u4e2d\u3001\u7cd6\u5c3f\u75c5\u3001\u304a\u3088\u3073\u9ad8\u30b3\u30ec\u30b9\u30c6\u30ed\u30fc\u30eb\u8840\u75c7\u306a\u3069\u306e\u5fc3\u8840\u7ba1\u969c\u5bb3\u306f\u3001AD\u306e\u767a\u75c7\u306b\u95a2\u308f\u308b\u5168\u8eab\u6027\u708e\u75c7\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002\u4ed6\u306e\u8981\u56e0\u3068\u3057\u3066\u306f\u3001\u5ea7\u308a\u304c\u3061\u306a\u751f\u6d3b\u69d8\u5f0f\u3001\u80a5\u6e80\u3001\u53e3\u8154\u5185\u306e\u4e0d\u885b\u751f\u3001\u304a\u3088\u3073\u982d\u90e8\u5916\u50b7\u304c\u6319\u3052\u3089\u308c\u3001\u7279\u306b\u305d\u308c\u304c\u91cd\u5ea6\u3001\u53cd\u5fa9\u7684\u3067\u3042\u3063\u305f\u308a\u3001\u610f\u8b58\u55aa\u5931\u3092\u4f34\u3046\u5834\u5408\u306fAD\u306e\u767a\u75c7\u306b\u5bc4\u4e0e\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u00a0<sup>*13,16\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-137.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3240 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-137.jpg\" alt=\"AD\u306e\u4e3b\u8981\u306a2\u5f62\u614b\u3067\u3042\u308b\u65e9\u671f\u767a\u75c7\uff08\u5bb6\u65cf\u6027\uff09\u304a\u3088\u3073\u6669\u671f\u767a\u75c7\u306e\u5909\u7570\u578b\" width=\"378\" height=\"270\" \/><\/a><\/p>\n<h4>\u75c5\u72b6<\/h4>\n<p>AD\u3068\u8a3a\u65ad\u3055\u308c\u305f\u60a3\u8005\u306e\u7d04\u534a\u6570\u306b\u306f\u3001\u30ec\u30d3\u30fc\u5c0f\u4f53\u578b\u8a8d\u77e5\u75c7\uff08LBD\uff09\u3084\u8840\u7ba1\u6027\u8a8d\u77e5\u75c7\u306a\u3069\u306e\u4ed6\u306e\u8a8d\u77e5\u75c7\u306e\u5f62\u614b\u306b\u95a2\u9023\u3059\u308b\u75c5\u7406\u5b66\u7684\u7279\u5fb4\u306e\u75d5\u8de1\u304c\u307f\u3089\u308c\u307e\u3059\u00a0<sup>*4<\/sup> \u3002AD\u306e\u5146\u5019\u306f\u3001\u8001\u4eba\u6591\u3084\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306a\u3069\u306e\u795e\u7d4c\u75c5\u7406\u5b66\u7684\u5909\u5316\u304c\u51fa\u73fe\u3057\u3066\u304b\u3089\u6570\u5e74\u5f8c\u306b\u73fe\u308c\u307e\u3059\u3002\u52a0\u9f62\u306b\u4f34\u3044\u3001\u8efd\u5ea6\u306e\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u306f\u73fe\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u3053\u306e\u4e2d\u3067AD\u3092\u767a\u75c7\u3059\u308b\u306b\u81f3\u308b\u60a3\u8005\u306f\u4e00\u90e8\u3067\u3059\u00a0<sup>*3<\/sup> \u3002\u75be\u60a3\u306e\u9032\u884c\u306f\u69d8\u3005\u3067\u3059\u304c\u3001\u4e00\u822c\u7684\u306b\u306f8\uff5e10\u5e74\u3067\u6b7b\u306b\u81f3\u308a\u307e\u3059\u3002\u6cbb\u7642\u6cd5\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u304c\u3001\u5256\u691c\u524d\u306e\u8a3a\u65ad\u306f80\uff5e90\uff05\u306e\u78ba\u7387\u3067\u6b63\u78ba\u3067\u3059\u00a0<sup>*3<\/sup> \u3002\u3053\u306e\u72b6\u6cc1\u306e\u53b3\u3057\u3055\u304b\u3089\u3001\u65e9\u671f\u306e\u8a3a\u65ad\u304a\u3088\u3073\u75be\u60a3\u306e\u9032\u884c\u901f\u5ea6\u3092\u6291\u3048\u308b\u305f\u3081\u306e\u6cbb\u7642\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u65b0\u3057\u3044\u7814\u7a76\u7d50\u679c\u306e\u767a\u6398\u304c\u91cd\u8981\u3067\u3042\u308b\u3053\u3068\u306f\u660e\u3089\u304b\u3067\u3059\u3002<\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/primary-antibodies\/research-area-antibodies\/neurobiology-antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u306b\u304a\u3051\u308b\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u691c\u51fa\u306b\u7528\u3044\u3089\u308c\u308b\u69d8\u3005\u306a\u7814\u7a76\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306e\u4f7f\u7528\u306b\u3064\u3044\u3066\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u6e08\u307f\u306e\u6297\u4f53\u306e\u5e83\u7bc4\u306a\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u8a73\u3057\u3044\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044<\/a>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-138.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3241 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-138.jpg\" alt=\"AD\u306b\u95a2\u9023\u3059\u308b\u4ee3\u8868\u7684\u306a\u907a\u4f1d\u5b50\u7523\u7269\" width=\"816\" height=\"701\" \/><\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u75c5\u7406\u5b66\u304a\u3088\u3073\u75c5\u614b\u751f\u7406\u5b66<\/h2>\n<h4>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u7279\u5fb4<\/h4>\n<p>\u7d30\u80de\u5916\u30a2\u30df\u30ed\u30a4\u30c9\u30d7\u30e9\u30fc\u30af\u306e\u5b58\u5728\u3001\u7d30\u80de\u5185\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u3001\u304a\u3088\u3073\u30cb\u30e5\u30fc\u30ed\u30f3\u9593\u306e\u30b7\u30ca\u30d7\u30b9\u7d50\u5408\u306e\u55aa\u5931\u306f\u3001AD\u306e\u9855\u5fae\u93e1\u30ec\u30d9\u30eb\u306e\u4e3b\u8981\u306a\u7279\u5fb4\u3067\u3059\uff08\u56f33.3\uff09<sup>*17<\/sup> \u3002\u30a2\u30df\u30ed\u30a4\u30c9\u30d7\u30e9\u30fc\u30af\u306e\u5b58\u5728\u306f\u3001\u81e8\u5e8a\u7684\u306b\u91cd\u8981\u306a\u8a18\u61b6\u969c\u5bb3\u304c\u767a\u75c7\u3059\u308b10\uff5e15\u5e74\u524d\u306b\u78ba\u8a8d\u3055\u308c\u307e\u3059\u3002AD\u60a3\u8005\u306e\u6570\u306f\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\uff08\u30ec\u30d3\u30fc\u5c0f\u4f53\uff09\u304a\u3088\u3073\u5e83\u7bc4\u306a\u30a8\u30d3\u30c7\u30f3\u30b9\u3068\u3057\u3066\u4ed6\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7d30\u80de\u5185\u51dd\u96c6\u306e\u5b58\u5728\u3082\u793a\u3055\u308c\u307e\u3059\u3002\u5b9f\u969b\u3001\u7279\u306b\u9ad8\u9f62\u60a3\u8005\u306b\u304a\u3044\u3066\u3001AD\u3068\u30ec\u30d3\u30fc\u5c0f\u4f53\u578b\u8a8d\u77e5\u75c7\u3001\u524d\u982d\u5074\u982d\u8a8d\u77e5\u75c7\u3001\u304a\u3088\u3073\u8133\u8840\u7ba1\u75be\u60a3\u306a\u3069\u306e\u4ed6\u306eCNS\u75be\u60a3\u306e\u9593\u306b\u306f\u30aa\u30fc\u30d0\u30fc\u30e9\u30c3\u30d7\u3059\u308b\u75c7\u72b6\u304c\u3042\u308a\u307e\u3059<sup>*5<\/sup> \u3002\u8089\u773c\u306b\u3088\u308bAD\u306e\u89e3\u5256\u5b66\u7684\u7279\u5fb4\u3068\u3057\u3066\u306f\u3001\u540c\u5e74\u9f62\u306e\u5065\u5e38\u8005\u3068\u306e\u6bd4\u8f03\u306b\u304a\u3051\u308b\u6d77\u99ac\u306e\u59d4\u7e2e\u304a\u3088\u3073\u8133\u5ba4\u306e\u62e1\u5927\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002AD\u304c\u9032\u884c\u3059\u308b\u306e\u306b\u4f34\u3044\u3001\u75be\u60a3\u5f8c\u671f\u306b\u4e00\u6642\u7684\u3067\u90e8\u5206\u7684\u306a\u5f8c\u982d\u8449\u304a\u3088\u3073\u524d\u982d\u90e8\u306e\u59d4\u7e2e\u304c\u751f\u3058\u307e\u3059\u00a0<sup>*18-20 <\/sup>\u3002<\/p>\n<p>AD\u306e\u795e\u7d4c\u75c5\u7406\u5b66\u7684\u7279\u5fb4\u3068\u3057\u3066\u306f\u3001A\u03b2\u51dd\u96c6\u7269\u304b\u3089\u306a\u308b\u7d30\u80de\u5916\u30d7\u30e9\u30fc\u30af\u304a\u3088\u3073\u9ad8\u30ea\u30f3\u9178\u5316\u30bf\u30a6\u306e\u7d30\u80de\u5185\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u58ca\u6ec5\u7684\u306a\u75be\u60a3\u306f\u3001\u30b7\u30ca\u30d7\u30b9\u306e\u640d\u5931\u304a\u3088\u3073\u8133\u840e\u7e2e\u306b\u3064\u306a\u304c\u308b\u795e\u7d4c\u7d30\u80de\u6b7b\u306b\u3088\u3063\u3066\u7279\u5fb4\u4ed8\u3051\u3089\u308c\u307e\u3059\u3002Wnt\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u7d4c\u8def\u306f\u3001\u795e\u7d4c\u6a5f\u80fd\u304a\u3088\u3073\u30b7\u30ca\u30d7\u30b9\u7dad\u6301\u306e\u6052\u5e38\u6027\u5236\u5fa1\u306b\u304a\u3044\u3066\u6975\u3081\u3066\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u3053\u306e\u30b7\u30b0\u30ca\u30eb\u7d4c\u8def\u306e\u64b9\u4e71\u306fAD\u306e\u767a\u75c7\u306b\u95a2\u4e0e\u3057\u3066\u3044\u307e\u3059\u3002\u8907\u6570\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u3001Wnt3a\u30ea\u30ac\u30f3\u30c9\u3092\u4ecb\u3059\u308b\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u306e\u819c\u900f\u904e\u6027\u3092\u963b\u5bb3\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u540c\u69d8\u306b\u3001Wnt5a\u30ea\u30ac\u30f3\u30c9\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306f\u3001AD\u306b\u304a\u3051\u308b\u6838\u5206\u88c2\u6838\u878d\u5408\u306e\u5909\u5316\u3092\u5236\u9650\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u306e\u5b8c\u5168\u6027\u3092\u4fdd\u8b77\u3057\u307e\u3059\uff08\u56f33.4\uff09\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-139.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3242 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-139.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u89e3\u5256\u5b66\u7684\u7279\u5fb4\" width=\"401\" height=\"663\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-140.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3243 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-140.jpg\" alt=\"\u514d\u75ab\u7d44\u7e54\u5316\u5b66\u306b\u304a\u3051\u308bWNT 3 \u30e4\u30ae\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\" width=\"817\" height=\"266\" \/><\/a><\/p>\n<h4>\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP\uff09\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u306e\u5f79\u5272<\/h4>\n<p>\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP)\u306f\u5185\u5728\u6027\u819c\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3001\u7570\u306a\u308b\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u3092\u53d7\u3051\u3066\u3001\u69d8\u3005\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u65ad\u7247\u3092\u751f\u6210\u3057\u307e\u3059\u3002\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001APP\u306f\u6700\u521d\u306b\u03b1-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306b\u3088\u3063\u3066\u5207\u65ad\u3055\u308c\u3001sAPP\u03b1\u3068C83\u3068\u3044\u3046C\u672b\u7aef\u65ad\u7247\u3092\u751f\u3058\u307e\u3059\u3002sAPP\u03b1\u306e\u5b58\u5728\u306f\u3001\u6b63\u5e38\u306a\u30b7\u30ca\u30d7\u30b9\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u3068\u95a2\u308f\u3063\u3066\u304a\u308a\u3001\u30b7\u30ca\u30d7\u30b9\u53ef\u5851\u6027\u3001\u5b66\u7fd2\u3068\u8a18\u61b6\u3001\u60c5\u52d5\u884c\u52d5\u3001\u304a\u3088\u3073\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u751f\u5b58\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001C83\u304c\u03b3-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306b\u3088\u3063\u3066\u5206\u89e3\u3055\u308c\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u7d30\u80de\u5185\u30c9\u30e1\u30a4\u30f3\u304a\u3088\u3073p3\u3092\u7523\u751f\u3057\u307e\u3059\u3002\u75c5\u7684\u72b6\u614b\u3067\u306f\u3001\u03b2\u90e8\u4f4d\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\u2013\u5207\u65ad\u9175\u7d20\uff08BACE-1\uff09\u304cAPP\u306b\u4f5c\u7528\u3057\u3001\u53ef\u6eb6\u6027APP\u03b2 (sAPP\u03b2)\u3092\u904a\u96e2\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u7d30\u80de\u5916\u7a7a\u9593\u306b\u653e\u51fa\u3055\u308c\u3001C99\u306f\u7d30\u80de\u819c\u306b\u4fdd\u6301\u3055\u308c\u307e\u3059\uff08\u56f33.5\uff09\u3002\u305d\u306e\u5f8c\u3001C99\u306f\u03b3-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u3067\u5206\u89e3\u3055\u308c\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u7d30\u80de\u5185\u30c9\u30e1\u30a4\u30f3\uff08AICD\uff09\u3092\u751f\u3058\u3001A\u03b2\u304c\u7d30\u80de\u5916\u7a7a\u9593\u306b\u653e\u51fa\u3055\u308c\u307e\u3059\u3002\u03b3-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306f\u3001\u30d7\u30ec\u30bb\u30cb\u30ea\u30f31\u304a\u3088\u30732\uff08PS-1\u304a\u3088\u3073PS-2\uff09\u3092\u542b\u3080\u8907\u6570\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u304b\u3089\u69cb\u6210\u3055\u308c\u307e\u3059\uff08\u88683.2\uff09\u3002PS-1\u304a\u3088\u3073PS-2\u3092\u30b3\u30fc\u30c9\u3059\u308b\u907a\u4f1d\u5b50\uff08PSEN1\u304a\u3088\u3073PSEN2\uff09\u306b\u306f\u3001150\u3092\u8d85\u3048\u308b\u69d8\u3005\u306a\u5909\u7570\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u5927\u90e8\u5206\u306fPSEN1\u306b\u304a\u3051\u308b\u5909\u7570\u3067\u3059\u3002PS\u5909\u7570\u306fAPP\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u3001A\u03b240\u3088\u308a\u3082A\u03b242\u306e\u51dd\u96c6\u3092\u5897\u52a0\u3055\u305b\u307e\u3059\u00a0<sup>*21,22\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-141.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3244 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-141.jpg\" alt=\"\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP\uff09\u306e\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\" width=\"400\" height=\"388\" \/><\/a><\/p>\n<p>\u975e\u30a2\u30df\u30ed\u30a4\u30c9\u5f62\u6210\u6027\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP\uff09\u306e\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u4e2d\u3001\u03b1-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306fAPP\u306b\u4f5c\u7528\u3057\u3001C83\u3068sAPP\u03b1\u3092\u7523\u751f\u3057\u307e\u3059\u3002sAPP\u03b1\u306f\u6b63\u5e38\u306a\u30b7\u30ca\u30d7\u30b9\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u306b\u95a2\u308f\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001C83\u306f\u03b3-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306b\u3088\u3063\u3066\u5206\u89e3\u3055\u308c\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u7d30\u80de\u5185\u30c9\u30e1\u30a4\u30f3\u304a\u3088\u3073p3\u3092\u7523\u751f\u3057\u307e\u3059\u3002\u30a2\u30df\u30ed\u30a4\u30c9\u5f62\u6210\u6027APP\u306e\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u4e2d\u3001\u03b2\u90e8\u4f4d\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea-\u5207\u65ad\u9175\u7d20\uff08BACE-1\uff09\u306fAPP\u306b\u4f5c\u7528\u3057\u3001\u53ef\u6eb6\u6027APP\u03b2\uff08sAPP\u03b2\uff09\u3092\u904a\u96e2\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u7d30\u80de\u5916\u7a7a\u9593\u306b\u653e\u51fa\u3055\u308c\u3001C99\u306f\u7d30\u80de\u819c\u306b\u4fdd\u6301\u3055\u308c\u307e\u3059\u3002\u03b3-\u30bb\u30af\u30ec\u30bf\u30fc\u30bc\u306f\u3001C99\u3092\u5207\u65ad\u3057\u3066\u30a2\u30df\u30ed\u30a4\u30c9\u7d30\u80de\u5185\u30c9\u30e1\u30a4\u30f3\uff08AICD\uff09\u3092\u751f\u3058\u3001\u7d30\u80de\u5916\u7a7a\u9593\u306bA\u03b2\u3092\u653e\u51fa\u3055\u305b\u308b\u9175\u7d20\u8907\u5408\u4f53\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-142.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3245 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-142.jpg\" alt=\"\u30d7\u30ec\u30bb\u30cb\u30ea\u30f31\u30de\u30a6\u30b9\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\uff08APS 18\uff09\u3000\" width=\"400\" height=\"593\" \/><\/a><\/p>\n<h4>\u6297\u4f53\uff1a \u7814\u7a76\u306e\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb<\/h4>\n<p>\u5f53\u793e\u3067\u306f\u3001\u795e\u7d4c\u751f\u7269\u5b66\u95a2\u9023\u306e\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u30ad\u30c3\u30c8\u306e\u5e45\u5e83\u3044\u88fd\u54c1\u7fa4\u306b\u52a0\u3048\u3066\u3001\u795e\u7d4c\u89e3\u5256\u304a\u3088\u3073\u6a5f\u80fd\u5206\u6790\u7528\u86cd\u5149\u30d7\u30ed\u30fc\u30d6\u3001\u30cb\u30e5\u30fc\u30ed\u30f3\u30c8\u30ec\u30fc\u30b5\u30fc\u3001\u306a\u3089\u3073\u306b\u521d\u4ee3\u7d30\u80de\u304a\u3088\u3073\u5e79\u7d30\u80de\u7814\u7a76\u7528\u306e\u795e\u7d4c\u7d30\u80de\u57f9\u990a\u8a66\u85ac\u3092\u542b\u3080\u795e\u7d4c\u79d1\u5b66\u7814\u7a76\u3092\u4fc3\u9032\u3059\u308b\u305f\u3081\u306e\u8a66\u85ac\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3246 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-143.jpg\" alt=\"APP\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u306b\u95a2\u4e0e\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\" width=\"800\" height=\"523\" \/><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/primary-antibodies\/research-area-antibodies\/neurobiology-antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306e\u6297\u4f53\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h4>\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u304a\u3088\u3073\u30d7\u30e9\u30fc\u30af\u306e\u5f62\u6210<\/h4>\n<p>A\u03b2\u30da\u30d7\u30c1\u30c9\u306f\u3001\u6b63\u5e38\u306a\u4ee3\u8b1d\u306b\u304a\u3044\u3066\u7523\u751f\u3059\u308b\u300136\uff5e43\u30a2\u30df\u30ce\u9178\u304b\u3089\u306a\u308b\u7523\u7269\u3067\u3059\u3002A\u03b240\u30e2\u30ce\u30de\u30fc\u306f\u3001\u81ea\u5df1\u51dd\u96c6\u6027\u304c\u9ad8\u3044\u50be\u5411\u306e\u3042\u308bA\u03b242\u3088\u308a\u3082\u9ad8\u30ec\u30d9\u30eb\u3067\u5b58\u5728\u3057\u307e\u3059\u3002A\u03b240\u3068A\u03b242\u306f\u9ad8\u983b\u5ea6\u3067\u91cd\u5408\u3057\u3066\u3001\u795e\u7d4c\u6bd2\u6027\u3092\u793a\u3059\u30aa\u30ea\u30b4\u30de\u30fc\u304a\u3088\u3073\u3088\u308a\u5927\u304d\u3044\u51dd\u96c6\u4f53\u3092\u5f62\u6210\u3057\u3001\u30a4\u30aa\u30f3\u30c1\u30e3\u30f3\u30cd\u30eb\u306e\u906e\u65ad\u3001\u30ab\u30eb\u30b7\u30a6\u30e0\u6052\u5e38\u6027\u306e\u5d29\u58ca\u3001\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u9178\u5316\u30b9\u30c8\u30ec\u30b9\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u4ee3\u8b1d\u306e\u969c\u5bb3\u3001\u304a\u3088\u3073\u6700\u7d42\u7684\u306b\u795e\u7d4c\u7d30\u80de\u6b7b\u306b\u3064\u306a\u304c\u308b\u8840\u7cd6\u8abf\u7bc0\u7570\u5e38\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u521d\u671f\u306e\u7814\u7a76\u3067\u306f\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u306e\u4e0d\u6eb6\u6027\u51dd\u96c6\u4f53\u304c\u6709\u6bd2\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u3001\u3088\u308a\u6700\u8fd1\u306e\u30a8\u30d3\u30c7\u30f3\u30b9\u3067\u306f\u53ef\u6eb6\u6027\u30aa\u30ea\u30b4\u30de\u30fc\u524d\u99c6\u4f53\u3082\u6709\u6bd2\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*23,24<\/sup> \u3002\u307e\u305f\u3001\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u306f\u3001\u5168A\u03b2\u30ec\u30d9\u30eb\u3088\u308a\u3082\u3080\u3057\u308dA\u03b2\u30aa\u30ea\u30b4\u30de\u30fc\u306e\u30ec\u30d9\u30eb\u306b\u5bfe\u5fdc\u3057\u3066\u767a\u73fe\u3057\u307e\u3059\u00a0<sup>*22<\/sup> \u3002A\u03b2\u306e\u84c4\u7a4d\u306f\u3001\u30bf\u30a6\u306e\u904e\u5270\u30ea\u30f3\u9178\u5316\u304a\u3088\u3073\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306e\u5f62\u6210\u306b\u5148\u7acb\u3063\u3066\u751f\u3058\u307e\u3059\uff08\u56f33.6\uff09\u00a0<sup>*25<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-144.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3247 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-144.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306b\u304a\u3051\u308b\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u30d7\u30e9\u30fc\u30af\u304a\u3088\u3073\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306e\u5f62\u6210\" width=\"536\" height=\"407\" \/><\/a><\/p>\n<h4>\u30bf\u30a6\u30bf\u30f3\u30d1\u30af\u8cea<\/h4>\n<p>\u5fae\u5c0f\u7ba1\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\uff08MAP\uff09\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u30ea\u30f3\u306b\u7d50\u5408\u3057\u3066\u3001\u5fae\u5c0f\u7ba1\u306e\u91cd\u5408\u304a\u3088\u3073\u5b89\u5b9a\u6027\u3092\u4fc3\u9032\u3057\u3001\u30ea\u30f3\u9178\u5316\u3055\u308c\u305fMAP\u3092\u5fae\u5c0f\u7ba1\u304b\u3089\u89e3\u96e2\u3057\u307e\u3059\u00a0<sup>*26<\/sup> \u3002\u30bf\u30a6\u306f\u3001\u30cb\u30e5\u30fc\u30ed\u30f3\u306b\u304a\u3051\u308b\u4e3b\u8981\u306aMAP\u3067\u3001\u6b63\u5e38\u306a\u72b6\u614b\u3067\u306f\u3001\u53ef\u6eb6\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u3057\u3066\u7d30\u80de\u4f53\u304a\u3088\u3073\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u8ef8\u7d22\u306b\u4f4d\u7f6e\u3057\u307e\u3059\u3002AD\u306b\u304a\u3044\u3066\u3001\u9ad8\u30ea\u30f3\u9178\u5316\u30bf\u30a6\u306f\u3001\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\uff08NFT\uff09\u304a\u3088\u3073\u795e\u7d4c\u7d68\u6bdb\u7cf8\uff08NT\uff09\u306e\u5f62\u6210\u3092\u5c0e\u304d\u307e\u3059\u00a0<sup>*27,28<\/sup>\u3002<br \/>\nA\u03b2\u306e\u84c4\u7a4d\u306fAD\u3068\u95a2\u9023\u3057\u307e\u3059\u304c\u3001\u6b63\u5e38\u306a\u52a0\u9f62\uff08\u81e8\u5e8a\u7684\u306a\u8a8d\u77e5\u75c7\u3092\u9664\u304f\uff09\u306b\u304a\u3051\u308b\u8133\u5185\u306b\u3082\u84c4\u7a4d\u3057\u307e\u3059\u3002A\u03b2\u306f\u3001AD\u306e\u91cd\u75c7\u5ea6\u3068\u306e\u76f8\u95a2\u6027\u3088\u308a\u3082\u3001\u8efd\u5ea6\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u3092\u6709\u3059\u308b\u60a3\u8005\u306eAD\u306b\u9032\u884c\u3059\u308b\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u306e\u4e88\u6e2c\u306b\u304a\u3044\u3066\u91cd\u8981\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002AD\u89e3\u6790\u306b\u304a\u3051\u308b\u65b0\u3057\u3044\u30b3\u30f3\u30bb\u30d7\u30c8\u3067\u306f\u3001\u30ea\u30f3\u9178\u5316\u30bf\u30f3\u30d1\u30af\u8cea\u30bf\u30a6\u306e\u75c5\u614b\u751f\u7406\u5b66\u3068AD\u306b\u304a\u3051\u308b\u81e8\u5e8a\u7684\u8a8d\u77e5\u75c7\u3068\u306e\u9ad8\u3044\u76f8\u95a2\u95a2\u4fc2\u306b\u7740\u76ee\u3057\u307e\u3059\u00a0<sup>*27,29<\/sup> \u3002\u3053\u306e\u305f\u3081\u3001AD\u7814\u7a76\u306b\u304a\u3044\u3066\u3001\u30bf\u30a6\u306e\u5f79\u5272\u306b\u306f\u3088\u308a\u9ad8\u3044\u6ce8\u76ee\u304c\u96c6\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h4>\u30bf\u30a6\u306e\u7279\u6027<\/h4>\n<ul>\n<li>\u67d3\u8272\u4f5317\u756a\u4e0a\u306eMAPT\u907a\u4f1d\u5b50<\/li>\n<li>\u5225\u3005\u306e\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u3063\u3066\u7523\u751f\u3059\u308b6\u7a2e\u985e\u306e\u7570\u306a\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0<\/li>\n<li>\u6700\u592780\u306e\u30bb\u30ea\u30f3\/\u30b9\u30ec\u30aa\u30cb\u30f3\u30ea\u30f3\u9178\u5316\u90e8\u4f4d\u3092\u542b\u6709<\/li>\n<li>5\u3064\u306e\u30c1\u30ed\u30b7\u30f3\u30ea\u30f3\u9178\u5316\u90e8\u4f4d\u3092\u542b\u6709<\/li>\n<li>AD\u8133\u304b\u3089\u5358\u96e2\u3057\u305f\u30bf\u30a6\u306f3\u500d\u306e\u30ea\u30f3\u9178\u3092\u542b\u6709\uff08vs. \u5065\u5e38\u8133\u304b\u3089\u5358\u96e2\u3057\u305f\u30bf\u30a6\uff09<\/li>\n<\/ul>\n<h4>\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u304a\u3088\u3073\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306e\u5f79\u5272<\/h4>\n<p>\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\uff08BBB\u306e\u8840\u7ba1\u3092\u8986\u3046) \u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\uff08\u98df\u7d30\u80de\u3068\u3057\u3066\u6a5f\u80fd\u3059\u308b\uff09\u3092\u542b\u3080\u30b0\u30ea\u30a2\u7d30\u80de\u306f\u3001AD\u306b\u304a\u3051\u308b\u795e\u7d4c\u5909\u6027\u30d7\u30ed\u30bb\u30b9\u306b\u95a2\u4e0e\u3057\u307e\u3059\u3002\u30cb\u30e5\u30fc\u30ed\u30f3\u304a\u3088\u3073\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306f\u9023\u643a\u3057\u3066\u6a5f\u80fd\u3057\u3001A\u03b242\u30aa\u30ea\u30b4\u30de\u30fc\u3092\u7523\u751f\u3057\u307e\u3059\u3002A\u03b2\u30c0\u30a4\u30de\u30fc\u304a\u3088\u3073\u30c8\u30ea\u30de\u30fc\u306f\u3001\u30b7\u30ca\u30d7\u30b9\u4f1d\u9054\u306e\u969c\u5bb3\u3001\u9178\u5316\u30b9\u30c8\u30ec\u30b9\u306e\u8a98\u5c0e\u3001\u30bf\u30a6\u306e\u904e\u5270\u30ea\u30f3\u9178\u5316\u306e\u4fc3\u9032\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u306b\u5bfe\u3057\u6bd2\u6027\u3092\u793a\u3057\u3001\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u3092\u6d3b\u6027\u5316\u3057\u307e\u3059\u3002\u6d3b\u6027\u5316\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u306f\u3001\u795e\u7d4c\u7d30\u80de\u304a\u3088\u3073\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306b\u304a\u3051\u308b\u3055\u3089\u306a\u308bA\u03b242\u306e\u7523\u751f\u3092\u8a98\u5c0e\u3059\u308b\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u304a\u3088\u3073\u4ed6\u306e\u56e0\u5b50\u3092\u5206\u6ccc\u3057\u307e\u3059\u3002\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u3001\u795e\u7d4c\u708e\u75c7\u3001\u304a\u3088\u3073AD\u306e\u95a2\u4fc2\u306f\u3088\u304f\u78ba\u7acb\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u6982\u7565\u3092\u56f33.7\u306b\u793a\u3057\u307e\u3059\u00a0<sup>*30<\/sup> \u3002\u307e\u305f\u3001A\u03b242\u30aa\u30ea\u30b4\u30de\u30fc\u306f\u3001\u30df\u30a8\u30ea\u30f3\u3092\u542b\u3080\u3001\u30b3\u30ec\u30b9\u30c6\u30ed\u30fc\u30eb\u306e\u8c4a\u5bcc\u306a\u819c\u3092\u640d\u50b7\u3059\u308b\u3068\u3044\u3046\u30a8\u30d3\u30c7\u30f3\u30b9\u304c\u3042\u308a\u307e\u3059\u3002A\u03b2\u30aa\u30ea\u30b4\u30de\u30fc\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u7570\u306a\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u3088\u3063\u3066\u9664\u53bb\u3055\u308c\u307e\u3059\u3002\u30cd\u30d7\u30ea\u30e9\u30a4\u30b7\u30f3\uff08\u5225\u540d\uff1a\u819c\u30e1\u30bf\u30ed-\u30a8\u30f3\u30c9\u30da\u30d7\u30c1\u30c0\u30fc\u30bc\uff08MME\uff09\u304a\u3088\u3073\u30a4\u30f3\u30b9\u30ea\u30f3\u5206\u89e3\u9175\u7d20\u306e2\u7a2e\u985e\u306e\u30d7\u30ed\u30c6\u30a2\u30fc\u30bc\u306f\u3001A\u03b2\u3092\u5206\u89e3\u3057\u3001\u5b9a\u5e38\u72b6\u614b\u306eA\u03b2\u30ec\u30d9\u30eb\u3092\u4f4e\u4e0b\u3055\u305b\u307e\u3059\u3002\u30cd\u30d7\u30ea\u30e9\u30a4\u30b7\u30f3\u30ec\u30d9\u30eb\u306e\u4f4e\u4e0b\u306f\u8133\u306b\u304a\u3051\u308bA\u03b2\u84c4\u7a4d\u3092\u5c0e\u304d\u3001\u30a4\u30f3\u30b9\u30ea\u30f3\u5206\u89e3\u9175\u7d20\u306e\u6b20\u5931\u306fA\u03b2\u5206\u89e3\u309250\uff05\u4f4e\u4e0b\u3055\u305b\u3001\u3044\u305a\u308c\u304b\u306e\u9175\u7d20\u306e\u904e\u5270\u767a\u73fe\u306f\u30d7\u30e9\u30fc\u30af\u5f62\u6210\u3092\u6e1b\u5c11\u3055\u305b\u307e\u3059\u3002A\u03b2\u30aa\u30ea\u30b4\u30de\u30fc\u306f\u3001\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u306b\u3088\u3063\u3066\u3082\u53d6\u308a\u8fbc\u307e\u308c\u3001\u53d7\u52d5\u7684\u306a\u6d41\u308c\u3092\u4ecb\u3057\u3066\u8133\u810a\u9ac4\u6db2\u306b\u79fb\u884c\u3057\u3001\u30ea\u30dd\u30bf\u30f3\u30d1\u30af\u8cea\u53d7\u5bb9\u4f53\u95a2\u9023\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u5faa\u74b0\u306b\u53d6\u308a\u8fbc\u307e\u308c\u307e\u3059\u00a0<sup>*22,31<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-145.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3248 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-145.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u306e\u75c5\u7406\u904e\u7a0b\" width=\"551\" height=\"558\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3249 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-146.jpg\" alt=\"CD10\/MME Rabbit Polyclonal Antibody\" width=\"258\" height=\"567\" \/>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u6b63\u78ba\u306a\u539f\u56e0\u306f\u4e0d\u660e\u3067\u3059\u304c\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u30d7\u30e9\u30fc\u30af\u306e\u5f62\u6210\u304cAD\u767a\u75c7\u306b\u95a2\u308f\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u81a8\u5927\u306a\u30a8\u30d3\u30c7\u30f3\u30b9\u304c\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\nAD\u306a\u3069\u306e\u795e\u7d4c\u5909\u6027\u72b6\u614b\u306b\u3064\u3044\u3066\u7814\u7a76\u3059\u308b\u7814\u7a76\u8005\u3092\u652f\u63f4\u3059\u308b\u305f\u3081\u306b\u3001\u5f53\u793e\u3067\u306f\u30b5\u30f3\u30d7\u30eb\uff08\u4f8b\uff1a\u7d30\u80de\u57f9\u990a\u4e0a\u6e05\u3001\u7d44\u7e54\u30db\u30e2\u30b8\u30cd\u30fc\u30c8\u3001\u8133\u810a\u9ac4\u6db2\uff08CSF\uff09\u7b49\uff09\u306b\u542b\u307e\u308c\u308b\u30d2\u30c8A\u03b242\u3092\u5b9a\u91cf\u3059\u308b\u305f\u3081\u306e\u300196\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u304a\u3088\u3073\u30de\u30a4\u30af\u30ed\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc\u3092\u7528\u3044\u308b\u3001\u7814\u7a76\u4f7f\u7528\u9650\u5b9a\u306e\u9175\u7d20\u7d50\u5408\u514d\u75ab\u5438\u7740\u6e2c\u5b9a\u6cd5\uff08ELISA\uff09\u30ad\u30c3\u30c8\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u672c\u30ad\u30c3\u30c8\u306f\u3001\u30d2\u30c8A\u03b242\u306e\u5929\u7136\u578b\u304a\u3088\u3073\u5408\u6210\u578b\u3092\u8a8d\u8b58\u3057\u3001\u03b240\/A\u03b243\u3092\u691c\u51fa\u305b\u305a\u306b\u3001A\u03b242\u3092\u9078\u629e\u7684\u306b\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\uff08\u88fd\u54c1\u756a\u53f7 KHB3544\uff09<br \/>\n<strong>Amyloid beta 42 Ultrasensitive\u00a0ELISA Kit, Human<\/strong><\/p>\n<p>\u6027\u80fd\u7279\u5fb4<\/p>\n<ul>\n<li>\u611f\u5ea6: &lt;1 pg\/mL<\/li>\n<li>\u6a19\u6e96\u66f2\u7dda\u7bc4\u56f2\uff1a1.56-100 pg\/mL<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u30bf\u30a4\u30d7\uff1a\u7d30\u80de\u57f9\u990a\u4e0a\u6e05\u3001\u7d44\u7e54\u30db\u30e2\u30b8\u30cd\u30fc\u30c8\u3001CSF<\/li>\n<li>\u7a2e\u53cd\u5fdc\u6027\uff1a\u30d2\u30c8<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u91cf\uff1a50 \u03bcL\uff08\u5e0c\u91c8\u6e08\u307f\uff09<\/li>\n<\/ul>\n<p>\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-147.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3250 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-147.jpg\" alt=\"\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\" width=\"822\" height=\"198\" \/><\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays\/elisa-kits.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">ELISA\u306e\u5b8c\u5168\u306a\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h4>\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306e\u5f62\u6210<\/h4>\n<p>\u904e\u5270\u306b\u30ea\u30f3\u9178\u5316\u3055\u308c\u305f\u30bf\u30a6\u306f\u5fae\u5c0f\u7ba1\u304b\u3089\u89e3\u96e2\u3057\u3001\u6b63\u5e38\u306a\u30bf\u30a6\u306e\u30df\u30b9\u30d5\u30a9\u30fc\u30eb\u30c7\u30a3\u30f3\u30b0\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u6b63\u5e38\u306a\u30bf\u30a6\u3001MAP1\u304a\u3088\u3073MAP2\u3092\u6355\u6349\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u5fae\u5c0f\u7ba1\u306e\u4e0d\u5b89\u5b9a\u5316\u304a\u3088\u3073\u7d30\u80de\u5185\u306b\u304a\u3051\u308b\u30bf\u30a6\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30aa\u30ea\u30b4\u30de\u30fc\u5f62\u6210\u304c\u751f\u3058\u307e\u3059\u3002\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306f\u30bf\u30a6\u306e\u30aa\u30ea\u30b4\u30de\u30fc\u5316\u306e\u7d50\u679c\u3068\u3057\u3066\u8d77\u3053\u308a\u3001\u8ef8\u7d22\u8f38\u9001\u969c\u5bb3\u304a\u3088\u3073\u795e\u7d4c\u7d30\u80de\u306e\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3092\u8a98\u5c0e\u3057\u307e\u3059\uff08\u56f33.8\uff09\u00a0<sup>*22,28<\/sup> \u3002GSK-3 \u304a\u3088\u3073CDK5\u306f\u30bf\u30a6\u3092\u30ea\u30f3\u9178\u5316\u3059\u308b\u4e3b\u8981\u306a\u30ad\u30ca\u30fc\u30bc\u3067\u3059\u3002\u30bf\u30a6\u306f\u3001\u88683.3\u304a\u3088\u3073\u56f33.8\u306b\u793a\u3059\u3088\u3046\u306a\u591a\u304f\u306e\u4ed6\u306e\u30ad\u30ca\u30fc\u30bc\u304a\u3088\u3073\u30db\u30b9\u30d5\u30a1\u30bf\u30fc\u30bc\u306b\u3088\u3063\u3066\u3001\u305d\u308c\u305e\u308c\u30ea\u30f3\u9178\u5316\u304a\u3088\u3073\u8131\u30ea\u30f3\u9178\u5316\u3055\u308c\u307e\u3059\u00a0<sup>*28\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-148.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3251 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-148.jpg\" alt=\"\u9ad8\u30ea\u30f3\u9178\u5316\u30bf\u30a6\" width=\"582\" height=\"726\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-149.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3252 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-149.jpg\" alt=\"\u30bf\u30a6\u30ad\u30ca\u30fc\u30bc\u304a\u3088\u3073\u30db\u30b9\u30d5\u30a1\u30bf\u30fc\u30bc\" width=\"399\" height=\"699\" \/><\/a><\/p>\n<h4>\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306e\u6210\u5206<\/h4>\n<p>\u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u306f\u307b\u307c\u5168\u4f53\u7684\u306b\u9ad8\u30ea\u30f3\u9178\u5316\u30bf\u30a6\u304b\u3089\u69cb\u6210\u3055\u308c\u3066\u3044\u308b\u3068\u4e00\u822c\u7684\u306b\u8aa4\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u305d\u306e\u69cb\u9020\u306f\u30d3\u30e1\u30f3\u30c1\u30f3\u3001\u30a2\u30af\u30c1\u30f3\u3001\u30e6\u30d3\u30ad\u30c1\u30f3\u3001MAP2\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u3001\u304a\u3088\u3073\u30bf\u30a6\u306a\u3069\u306e\u795e\u7d4c\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u5bfe\u3059\u308b\u6297\u4f53\u3067\u6a19\u8b58\u53ef\u80fd\u3067\u3059 *<sup>29<\/sup>\u3002 \u795e\u7d4c\u539f\u7dda\u7dad\u5909\u5316\u3068\u5171\u5b58\u3059\u308b\u3053\u3068\u3067\u77e5\u3089\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u88683.4\u306b\u30ea\u30b9\u30c8\u30a2\u30c3\u30d7\u3057\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-150.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3253 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-150.jpg\" alt=\"\u5fae\u5c0f\u7ba1\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u304a\u3088\u3073\u795e\u7d4c\u539f\u7dda\u7dad\u30bf\u30f3\u30d1\u30af\u8cea\" width=\"486\" height=\"308\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-45.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3254 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-45.jpg\" alt=\"Vimentin Mouse Monoclonal Antibody (V9)\" width=\"814\" height=\"416\" \/><\/a><\/p>\n<p>\u5f53\u793e\u3067\u306f\u3001\u5b9a\u91cf\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u3057\u3066\u3001\u9ad8\u54c1\u8cea\u306e\u4e00\u6b21\u304a\u3088\u3073\u4e8c\u6b21\u6297\u4f53\u306e\u5e45\u5e83\u3044\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u52a0\u3048\u3066\u3001ELISA\u7528\u8a66\u85ac\u304a\u3088\u3073\u30a2\u30af\u30bb\u30b5\u30ea\u3001\u5358\u4e00\u30bf\u30fc\u30b2\u30c3\u30c8\u89e3\u6790\u7528\u306e\u6297\u4f53\u30da\u30a2\u3001\u306a\u3089\u3073\u306b\u795e\u7d4c\u751f\u7269\u5b66\u304a\u3088\u3073\u4ed6\u306e\u7814\u7a76\u5206\u91ce\u7528\u306e\u7c21\u4fbf\u3067\u3059\u3050\u306b\u4f7f\u3048\u308b\u5b8c\u5168\u306aELISA\u30ad\u30c3\u30c8\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u795e\u7d4c\u751f\u7269\u5b66\u7528ELISA\u306b\u52a0\u3048\u3066\u3001\u5f53\u793e\u306b\u306f\u4e0b\u8a18\u306e\u4ee3\u8868\u7684ELISA\u88fd\u54c1\u30ab\u30c6\u30b4\u30ea\u30fc\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30ea\u30f3\u9178ELISA<\/li>\n<li>\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u304a\u3088\u3073\u30b1\u30e2\u30ab\u30a4\u30f3ELISA<\/li>\n<\/ul>\n<p><strong>\u795e\u7d4c\u751f\u7269\u5b66\u7528ELISA<\/strong><br \/>\n\u795e\u7d4c\u751f\u7269\u5b66\u7528ELISA\u30ad\u30c3\u30c8\u306f\u3001\u795e\u7d4c\u75be\u60a3\u306e\u7814\u7a76\u3084\u795e\u7d4c\u79d1\u5b66\u95a2\u9023\u306e\u7814\u7a76\u3092\u652f\u63f4\u3059\u308b\u305f\u3081\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u9ad8\u54c1\u8ceaELISA\u30ad\u30c3\u30c8\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u201cneuroELISA\u201d\u30ad\u30c3\u30c8\u306f\u3001\u8133\u810a\u9ac4\u6db2\uff08CSF\uff09\u3001\u7d30\u80de\u57f9\u990a\u4e0a\u6e05\u3001\u521d\u4ee3\u30cb\u30e5\u30fc\u30ed\u30f3\u30e9\u30a4\u30bb\u30fc\u30c8\u3001\u304a\u3088\u3073\u8133\u7d44\u7e54\u30b5\u30f3\u30d7\u30eb\u306a\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u30bf\u30a4\u30d7\u306b\u304a\u3051\u308bA\u03b2\u3001\u30bf\u30a6\u3001\u304a\u3088\u3073\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6b63\u78ba\u3001\u9ad8\u611f\u5ea6\u3001\u304b\u3064\u8fc5\u901f\u306a\u5b9a\u91cf\u3092\u53ef\u80fd\u3068\u3059\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><strong>\u5f53\u793e\u306e\u795e\u7d4c\u751f\u7269\u5b66\u7528ELISA\u30ad\u30c3\u30c8\u306e\u5229\u70b9<\/strong><\/p>\n<ul>\n<li>\u6570\u767e\u4ef6\u3082\u306e\u795e\u7d4c\u79d1\u5b66\u5206\u91ce\u306e\u67fb\u8aad\u8ad6\u6587\u306b\u5f15\u7528<\/li>\n<li>ELISA\u5e02\u5834\u306725\u5e74\u306e\u5b9f\u7e3e<\/li>\n<li>\u53b3\u683c\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u0336\u611f\u5ea6\u3001\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u3001\u7cbe\u5ea6\u3001\u7279\u7570\u6027\u3001\u56de\u53ce\u7387\u3001\u304a\u3088\u3073\u30ed\u30c3\u30c8\u9593\u306e\u4e00\u8cab\u6027\u306a\u3069\u306e\u696d\u754c\u57fa\u6e96\u306e\u898f\u683c\u306b\u9069\u5408\u3057\u3001\u4fe1\u983c\u6027\u306e\u3042\u308b\u7d50\u679c\u3092\u5b9f\u73fe<\/li>\n<li>\u7c21\u4fbf\u0336\u3042\u3089\u304b\u3058\u3081\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u305f\u30d7\u30ec\u30fc\u30c8\u3001\u6355\u6349\u6297\u4f53\u304a\u3088\u3073\u691c\u51fa\u6297\u4f53\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u3001\u306a\u3089\u3073\u306b\u30a2\u30af\u30bb\u30b5\u30ea\u30fc\u8a66\u85ac\u3092\u542b\u3080\u3001ready-to-use\u306e\u30ad\u30c3\u30c8<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3255 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-151.jpg\" alt=\"\u5f53\u793e\u306eELISA \u30ad\u30c3\u30c8\u306b\u95a2\u3059\u308b\u4ee3\u8868\u7684\u306a\u6587\u732e\" width=\"812\" height=\"563\" \/><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays\/elisa-kits.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">ELISA\u306e\u5b8c\u5168\u306a\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h4>\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc<\/h4>\n<p>AD\u306e\u7d44\u7e54\u5b66\u7684\u304a\u3088\u3073\u89e3\u5256\u5b66\u7684\u7279\u5fb4\u306b\u95a2\u3059\u308b\u57fa\u790e\u7684\u306a\u79d1\u5b66\u60c5\u5831\u306f\u3001\u75be\u60a3\u691c\u51fa\u3084\u75be\u60a3\u9032\u884c\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u306e\u305f\u3081\u306e\u81e8\u5e8a\u7684\u65b9\u6cd5\u3092\u958b\u767a\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u73fe\u5728\u3067\u306f\u3001\u6570\u591a\u304f\u306e\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6cd5\u304a\u3088\u3073\u30bf\u30f3\u30d1\u30af\u8cea\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u6280\u8853\u304cAD\u306e\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u3092\u958b\u767a\u3059\u308b\u305f\u3081\u306e\u81e8\u5e8a\u8a66\u9a13\u306a\u3089\u3073\u306b\u88ab\u9a13\u8005\u306e\u9078\u629e\u306b\u65e5\u5e38\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002AD\u306e\u81e8\u5e8a\u304a\u3088\u3073\u5b9f\u9a13\u5ba4\u3067\u306e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u4f7f\u7528\u3055\u308c\u308b\u69d8\u3005\u306a\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u6982\u8981\u3092\u88683.5\u306b\u793a\u3057\u307e\u3059\u00a0<sup>*25<\/sup>\u3002<br \/>\n\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306f\u3001\u5ba2\u89b3\u7684\u306b\u6e2c\u5b9a\u304a\u3088\u3073\u8a55\u4fa1\u3067\u304d\u308b\u6307\u6a19\u3042\u308b\u3044\u306f\u5b9f\u4f53\u3067\u3042\u308a\u3001\u6b63\u5e38\u306a\u751f\u7269\u5b66\u7684\u904e\u7a0b\u3001\u767a\u75c5\u904e\u7a0b\u3001\u307e\u305f\u306f\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u3092\u793a\u3057\u307e\u3059\u3002\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u304c\u75be\u60a3\u306b\u7279\u7570\u7684\u3067\u3042\u308b\u305f\u3081\u306b\u306f\u3001\u305d\u306e\u5b58\u5728\u3001\u6fc3\u5ea6\u3001\u304a\u3088\u3073\/\u307e\u305f\u306f\u6d3b\u6027\u304c\u75be\u60a3\u3068\u95a2\u9023\u4ed8\u3051\u3089\u308c\u3066\u3044\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u00a0<sup>*25,32<\/sup> \u3002\u7d50\u679c\u7684\u306b\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306f\u3001\u75be\u60a3\u691c\u51fa\u3060\u3051\u3067\u306a\u304f\u3001\u75be\u60a3\u9032\u884c\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3001\u75be\u60a3\u767a\u75c7\u306e\u691c\u51fa\u3001\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3001\u3055\u3089\u306b\u75be\u60a3\u306e\u8aa4\u8a3a\u3092\u56de\u907f\u3059\u308b\u305f\u3081\u306b\u3082\u7528\u3044\u3089\u308c\u307e\u3059\u00a0<sup>*25<\/sup>\u3002<br \/>\n\u7406\u60f3\u7684\u306a\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u7279\u5fb4\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u9ad8\u9078\u629e\u7684\uff08\u307b\u307c\u5168\u3066\u306e\u75be\u60a3\u30b5\u30f3\u30d7\u30eb\u3067\u967d\u6027\u3092\u793a\u3059\uff09<\/li>\n<li>\u9ad8\u7279\u7570\u7684 \uff08\u5927\u90e8\u5206\u306e\u975e\u75be\u60a3\u30b5\u30f3\u30d7\u30eb\u3067\u9670\u6027\u3092\u793a\u3059\uff09<\/li>\n<li>\u75be\u60a3\u7d4c\u904e\u3092\u6b63\u78ba\u306b\u4e88\u6e2c<\/li>\n<li>\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u306e\u7a0b\u5ea6\u3092\u53cd\u6620<\/li>\n<\/ul>\n<p>AD\u3068\u8a3a\u65ad\u3055\u308c\u305f\u60a3\u8005\u306e\u5727\u5012\u7684\u591a\u6570\u306f\u3001\u65e2\u306b\u8a8d\u77e5\u6a5f\u80fd\u304c\u640d\u306a\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u306eAD\u7814\u7a76\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3092\u4f7f\u7528\u3057\u3066\u3001\u75c7\u72b6\u306e\u767a\u75c7\u524d\u306b\u75be\u60a3\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u7814\u7a76\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u75be\u60a3\u306e\u521d\u671f\u6bb5\u968e\u306b\u8fc5\u901f\u304b\u3064\u52b9\u679c\u7684\u306a\u6cbb\u7642\u3092\u884c\u3044\u3001\u521d\u671f\u306b\u75be\u60a3\u9032\u884c\u3092\u6291\u5236\u307e\u305f\u306f\u9045\u5ef6\u3055\u305b\u308b\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u3092\u958b\u767a\u3059\u308b\u3053\u3068\u3092\u6700\u7d42\u76ee\u6a19\u3068\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059 *<sup>25<\/sup>\u3002 \u751f\u5316\u5b66\u30de\u30fc\u30ab\u30fc\u304a\u3088\u3073\u69cb\u9020\u30de\u30fc\u30ab\u30fc\u306a\u3089\u3073\u306b\u81e8\u5e8a\u75c7\u72b6\u306e\u4e00\u6642\u7684\u306a\u767a\u73fe\u304a\u3088\u3073\u84c4\u7a4d\u3092\u56f33.9\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-152.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3256 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-152.jpg\" alt=\"\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u30b9\u30c6\u30fc\u30b8\u306e\u95a2\u4fc2\" width=\"419\" height=\"440\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3257 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-153.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u691c\u51fa\u306e\u305f\u3081\u306e\u4e00\u822c\u7684\u306a\u65b9\u6cd5\" width=\"808\" height=\"224\" \/>Luminex\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u6280\u8853\u3092\u7528\u3044\u305f\u30c7\u30fc\u30bf\u51fa\u529b\u306e\u6700\u5927\u5316\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u7814\u7a76\u306e\u6210\u529f\u3092\u4fc3\u9032\u3059\u308b\u305f\u3081\u306b\u3001\u5f53\u793e\u306e\u65b0\u3057\u3044\u30ad\u30c3\u30c8\u306f\u3001\u6b63\u78ba\u3067\u4e00\u8cab\u3057\u305f\u3001\u30d2\u30c8\u8133\u810a\u9ac4\u6db2\u4e2d\u306eA\u03b240\u3001A\u03b242\u304a\u3088\u3073\u7dcf\u30bf\u30a6\u306e\u5b9a\u91cf\u7d50\u679c\u3092\u63d0\u4f9b\u3059\u308b\u3088\u3046\u72ec\u81ea\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7d44\u7e54\u30db\u30e2\u30b8\u30cd\u30fc\u30c8\u3001\u8840\u6f3f\u3001\u307e\u305f\u306f\u7d44\u7e54\u57f9\u990a\u4e0a\u6e05\u306a\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u30bf\u30a4\u30d7\u306b\u3082\u4f7f\u7528\u53ef\u80fd\u3068\u3055\u308c\u307e\u3059\u3002\uff08\u88fd\u54c1\u756a\u53f7 LHN0001M\uff09<br \/>\n<strong>Luminex\u2122 Platform\u306e\u305f\u3081\u306eInvitrogen\u2122 Amyloid beta (A\u03b2)\/TauNeurodegenerative Human Magnetic3-plex Panel\u306e\u5c0e\u5165<\/strong><\/p>\n<p>\u5f53\u793e\u306e\u30ad\u30c3\u30c8\u306e\u5229\u70b9<\/p>\n<ul>\n<li>3\u7a2e\u985e\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u540c\u6642\u89e3\u6790\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30eb\u306f\u308f\u305a\u304b15 \u03bcL\/well<\/li>\n<li>\u611f\u5ea6\u3001\u7279\u7570\u6027\u3001\u304a\u3088\u3073\u30ed\u30c3\u30c8\u9593\u306e\u4e00\u8cab\u6027\u306a\u3069\u306e\u57fa\u6e96\u306b\u3064\u3044\u3066\u53b3\u683c\u306a\u8a66\u9a13\u3092\u884c\u3044\u3001\u518d\u73fe\u6027\u304a\u3088\u3073\u6b63\u78ba\u306a\u7d50\u679c\u3092\u5b9f\u73fe<\/li>\n<li>\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u89e3\u6790\u306e\u52b9\u7387\u3001\u30b9\u30d4\u30fc\u30c9\u3001\u304a\u3088\u3073\u5e83\u3044\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u3068\u3001ELISA\u3068\u540c\u7b49\u306e\u7d50\u679c\u3092\u540c\u6642\u306b\u5b9f\u73fe<\/li>\n<\/ul>\n<p>\u5f53\u793e\u306e\u30ad\u30c3\u30c8\u306f\u3001Luminex\u2122 100\u2122\u3001200\u2122\u3001FLEXMAP 3D\u3001\u307e\u305f\u306fMAGPIX\u88c5\u7f6e\u306b\u304a\u3044\u3066\u4f7f\u7528\u3059\u308b\u3088\u3046\u306b\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-154.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3258 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-154.jpg\" alt=\"\u8840\u6f3f-EDTA\u306e\u56de\u53ce\" width=\"415\" height=\"326\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays\/procartaplex-assays-luminex\/procartaplex-immunoassays.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5b8c\u5168\u306aLuminex\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u95a2\u3059\u308b\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306b\u304a\u3051\u308b\u795e\u7d4c\u708e\u75c7<\/h2>\n<h4>\u795e\u7d4c\u708e\u75c7<\/h4>\n<p>\u8fd1\u5e74\u307e\u3067\u3001\u795e\u7d4c\u708e\u75c7\u306fAD\u9032\u884c\u306e\u5f8c\u671f\u306bA\u03b2\u304c\u84c4\u7a4d\u3059\u308b\u307e\u3067\u767a\u751f\u3057\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u8fd1\u5e74\u3001\u907a\u4f1d\u5b66\u304a\u3088\u3073\u30d0\u30a4\u30aa\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u7814\u7a76\u306b\u3088\u308a\u3001\u514d\u75ab\u7cfb\u306e\u6d3b\u6027\u5316\u306fAD\u767a\u75c7\u524d\u306e\u8efd\u5ea6\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u306e\u6bb5\u968e\u3067\u751f\u3058\u5f97\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u3055\u308c\u307e\u3057\u305f\u3002\u514d\u75ab\u7cfb\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3059\u308b\u907a\u4f1d\u5b50\u306b\u5909\u7570\u304c\u3042\u308b\u60a3\u8005\u3067\u306f\u3001\u7d44\u7e54\u304a\u3088\u3073\u4f53\u6db2\u306b\u304a\u3051\u308b\u514d\u75ab\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\u30ec\u30d9\u30eb\u306e\u5897\u52a0\u3068AD\u306e\u521d\u671f\u75c7\u72b6\u3068\u306e\u9593\u306b\u95a2\u4fc2\u304c\u307f\u3089\u308c\u308b\u3053\u3068\u304c\u89b3\u5bdf\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u4e7e\u766c\u3001\u80a5\u6e80\u75c7\u306a\u3069\u306e\u75c7\u72b6\u3067\u307f\u3089\u308c\u308b\u9ad8\u30ec\u30d9\u30eb\u306e\u708e\u75c7\u3092\u6709\u3059\u308b\u60a3\u8005\u306b\u304a\u3044\u3066\u306f\u3001AD\u3092\u767a\u75c7\u3059\u308b\u30ea\u30b9\u30af\u304c\u5897\u52a0\u3057\u307e\u3059\u3002\u7d2f\u7a4d\u8a3c\u62e0\u3067\u306f\u3001\u795e\u7d4c\u708e\u75c7\u304cAD\u767a\u75c7\u306e\u539f\u56e0\u3068\u306a\u308b\u5f71\u97ff\u3092\u4e0e\u3048\u3066\u3044\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*33,34<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-155.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3260 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-155.jpg\" alt=\"\u708e\u75c7\u304a\u3088\u3073\u795e\u7d4c\u7d30\u80de\u6b7b\u306b\u304a\u3051\u308b\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u304a\u3088\u3073\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306e \u5f79\u5272\" width=\"403\" height=\"409\" \/><\/a><\/p>\n<h4>\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de<\/h4>\n<p>\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u0336\u81ea\u7136\u514d\u75ab\u7cfb\u306e\u98df\u7d30\u80de\u0336\u306f\u3001AD\u306b\u304a\u3051\u308b\u795e\u7d4c\u708e\u75c7\u53cd\u5fdc\u3092\u5c0e\u304f\u4e3b\u8981\u306a\u8a98\u56e0\u3067\u3059\u3002\u3053\u306e\u7279\u6b8a\u5316\u3057\u305f\u7d30\u80de\u306f\u3001\u514d\u75ab\u76e3\u8996\u306e\u5f79\u5272\u3092\u62c5\u3044\u3001\u75c5\u539f\u4f53\u3084\u7d30\u80de\u30c7\u30d6\u30ea\u3092\u9664\u53bb\u3057\u3001\u8a18\u61b6\u5f62\u6210\u306b\u95a2\u4e0e\u3059\u308b\u6804\u990a\u56e0\u5b50\u3092\u5206\u6ccc\u3057\u307e\u3059\u00a0<sup>*33,34<\/sup>\u3002 AD\u767a\u75c5\u4e2d\u306e\u640d\u50b7\u3001\u5916\u50b7\u3001\u3042\u308b\u3044\u306fA\u03b2\u6c88\u7740\u306e\u84c4\u7a4d\u306f\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u306e\u6d3b\u6027\u5316\u3092\u5c0e\u304f\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u306f\u3001\u3053\u308c\u3089\u306e\u76f8\u4e92\u6d3b\u6027\u5316\u3092\u5c0e\u304f\u708e\u75c7\u8a98\u767a\u56e0\u5b50\u3092\u5206\u6ccc\u3057\u307e\u3059\u3002\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3001\u30b1\u30e2\u30ab\u30a4\u30f3\u3001\u304a\u3088\u3073\u6d3b\u6027\u9178\u7d20\u7a2e\u306a\u3069\u306e\u708e\u75c7\u7d30\u80de\u306b\u3088\u308a\u7523\u751f\u3057\u305f\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\u306f\u795e\u7d4c\u7d30\u80de\u6b7b\u3092\u5c0e\u304d\u307e\u3059\uff08\u56f33.10\u304a\u3088\u3073\u88683.6\uff09<sup>*34,35<\/sup>\u3002<\/p>\n<p>\u52a0\u9f62\u304a\u3088\u3073AD\u306b\u304a\u3051\u308b\u8840\u7ba1\u708e\u75c7\u306e\u8a3c\u62e0\u304c\u6570\u591a\u304f\u3042\u308b\u3088\u3046\u306b\u3001\u708e\u75c7\u306f\u8133\u5185\u3060\u3051\u3067\u306a\u304f\u3001BBB\u306e\u30ec\u30d9\u30eb\u3067\u3082\u751f\u3058\u307e\u3059\u3002BBB\u306e\u7834\u58ca\u306f\u3001\u8840\u7ba1\u8154\u304b\u3089CNS\u306b\u5358\u7403\u3092\u79fb\u884c\u3055\u305b\u3001\u708e\u75c7\u74b0\u5883\u3092\u3055\u3089\u306b\u60aa\u5316\u3055\u305b\u307e\u3059\u3002\u307e\u305f\u3001AD\u60a3\u8005\u306e\u8840\u7ba1\u306b\u306f\u3001\u540c\u5e74\u9f62\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u60a3\u8005\u3068\u6bd4\u8f03\u3057\u3066\u3001\u9ad8\u30ec\u30d9\u30eb\u306eIL-1\u03b2\u3001IL-6\u3001IL-8\u3001TNF-\u03b1\u3001TGF-\u03b2\u3001\u304a\u3088\u3073MCP-1\u304c\u542b\u307e\u308c\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u00a0<sup>*36\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-156.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3261 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-156.jpg\" alt=\"\u9078\u629e\u7684\u795e\u7d4c\u708e\u75c7\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\" width=\"401\" height=\"350\" \/><\/a><\/p>\n<h4>\u514d\u75ab\u7642\u6cd5<\/h4>\n<p>\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u306f\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u5206\u6ccc\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u6297\u539f\u3092\u8caa\u98df\u304a\u3088\u3073\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u3057\u3066\u3001T\u7d30\u80de\u306b\u63d0\u793a\u3059\u308b\u305f\u3081\u306e\u5c0f\u3055\u3044\u65ad\u7247\u3068\u3057\u307e\u3059\u3002\u6297\u539f\u63d0\u793a\u306fT\u7d30\u80de\u6d3b\u6027\u5316\u306e\u91cd\u8981\u306a\u8981\u7d20\u3067\u3001\u7d30\u80de\u7cfb\u8b5c\u306b\u4f9d\u5b58\u3057\u3001\u6d3b\u6027\u5316T\u7d30\u80de\u306f\u7d30\u80de\u3092\u6b7b\u6ec5\u3055\u305b\u308b\u304b\u3001\u514d\u75ab\u5fdc\u7b54\u3092\u6539\u5909\u3059\u308b\u305f\u3081\u306e\u3055\u3089\u306a\u308b\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u7523\u751f\u3057\u307e\u3059\u3002<\/p>\n<p>AD\u3067\u306f\u3001A\u03b2\u304a\u3088\u3073\u30bf\u30a6\u304c\u84c4\u7a4d\u3057\u3001\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u3001B\u7d30\u80de\u3001\u6a39\u72b6\u7d30\u80de\u304a\u3088\u3073\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u306a\u3069\u306e\u6297\u539f\u63d0\u793a\u7d30\u80de\u306b\u3088\u3063\u3066\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u3055\u308c\u307e\u3059\u00a0<sup>*37<\/sup>\u3002 A\u03b2\u304a\u3088\u3073\u30bf\u30a6\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306e\u514d\u75ab\u7cfb\u3092\u5229\u7528\u3059\u308b\u6226\u7565\u304c\u73fe\u5728\u9032\u884c\u3057\u3066\u3044\u307e\u3059\u3002\u7814\u7a76\u8005\u305f\u3061\u306f\u3001\u80fd\u52d5\u514d\u75ab\u7642\u6cd5\u3042\u308b\u3044\u306f\u53d7\u52d5\u514d\u75ab\u7642\u6cd5\u306b\u3088\u3063\u3066A\u03b2\u304a\u3088\u3073\u30bf\u30a6\u306e\u30ec\u30d9\u30eb\u3092\u4f4e\u4e0b\u3055\u305b\u3001\u305d\u308c\u306b\u3088\u308aAD\u306e\u75c5\u72b6\u306e\u9032\u884c\u3092\u9045\u5ef6\u307e\u305f\u306f\u505c\u6b62\u3067\u304d\u308b\u3053\u3068\u3092\u671f\u5f85\u3057\u3066\u3044\u307e\u3059\uff08\u56f33.11\uff09\u3002<\/p>\n<p>A\u03b2\u307e\u305f\u306f\u30bf\u30a6\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b\u30ef\u30af\u30c1\u30f3\u3084\u30d2\u30c8\u5316\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3092\u7528\u3044\u308b\u524d\u81e8\u5e8a\u8a66\u9a13\u3067\u306f\u3001AD\u306e\u75c5\u72b6\u306e\u8efd\u6e1b\u3068\u795e\u7d4c\u6bd2\u6027\u306e\u8efd\u6e1b\u306b\u6210\u529f\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u81e8\u5e8a\u8a66\u9a13\u0336AD\u306b\u5bfe\u3059\u308b\u80fd\u52d5\u514d\u75ab\u7642\u6cd5\u304a\u3088\u3073\u53d7\u52d5\u514d\u75ab\u7642\u6cd5\u306e\u4e21\u65b9\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u0336\u3067\u306f\u3001\u6709\u5bb3\u53cd\u5fdc\uff08\u9ac4\u819c\u8133\u708e\uff09\u3001\u30a2\u30df\u30ed\u30a4\u30c9\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u7570\u5e38\u3001\u304a\u3088\u3073\u6709\u52b9\u6027\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8\u306b\u5bfe\u3059\u308b\u60aa\u5f71\u97ff\u306a\u3069\u306e\u554f\u984c\u306b\u906d\u9047\u3057\u3066\u3044\u307e\u3059 *<sup>38,39<\/sup> \u3002\u73fe\u5728\u306f\u3001AD\u306e\u75c7\u767a\u73fe\u524d\u306e\u6295\u4e0e\u3084AD\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u514d\u75ab\u7642\u6cd5\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u958b\u767a\u306b\u304a\u3051\u308b\u80fd\u52d5\u514d\u75ab\u6cd5\u304a\u3088\u3073\u53d7\u52d5\u514d\u75ab\u6cd5\u306e\u5b89\u5168\u6027\u304a\u3088\u3073\u6709\u52b9\u6027\u306e\u6539\u5584\u306b\u7126\u70b9\u3092\u5f53\u3066\u3066\u7814\u7a76\u3092\u9032\u3081\u3066\u3044\u307e\u3059\u00a0<sup>*38\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-157.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3262 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-157.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u6cbb\u7642\u306e\u305f\u3081\u306e\u958b\u767a\u4e2d\u306e\u514d\u75ab\u5b66\u7684\u30a2\u30d7\u30ed\u30fc\u30c1\" width=\"812\" height=\"625\" \/><\/a><\/p>\n<h2>\u5b9f\u9a13\u7684\u6cbb\u7642\u85ac\u306e\u305f\u3081\u306e\u30bf\u30fc\u30b2\u30c3\u30c8<\/h2>\n<p>\u795e\u7d4c\u708e\u75c7\u3068\u75be\u60a3\u306e\u95a2\u4fc2\u306e\u7406\u89e3\u306b\u5bfe\u3059\u308b\u95a2\u5fc3\u306f\u9ad8\u307e\u3063\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u795e\u7d4c\u514d\u75ab\u7cfb\u306e\u98df\u7d30\u80de\u3067\u3042\u308b\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u306f\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3084\u4ed6\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u304a\u3051\u308b\u8133\u306e\u708e\u75c7\u53cd\u5fdc\u306b\u95a2\u308f\u308b\u9375\u3068\u306a\u308b\u8981\u7d20\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u6d3b\u6027\u9178\u7d20\u7a2e\u306b\u52a0\u3048\u3066\u3001\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u306f\u3001\u795e\u7d4c\u7d30\u80de\u6b7b\u3092\u5c0e\u304f\u53ef\u80fd\u6027\u306e\u3042\u308b\u708e\u75c7\u8a98\u767a\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u304a\u3088\u3073\u4ed6\u306e\u56e0\u5b50\u3092\u5206\u6ccc\u3057\u307e\u3059\u3002<\/p>\n<p>\u5f53\u793e\u3067\u306f\u3001\u795e\u7d4c\u708e\u75c7\u306b\u3064\u3044\u3066\u7814\u7a76\u3059\u308b\u305f\u3081\u306e\u6297\u4f53\u30a2\u30ec\u30a4\u3092\u5e45\u5e83\u304f\u53d6\u308a\u63c3\u3048\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u306e\u6297\u4f53\u306f\u3001\u514d\u75ab\u86cd\u5149\u3001\u514d\u75ab\u7d44\u7e54\u5316\u5b66\u3001ELISA\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3001\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u304a\u3088\u3073\u4ed6\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u542b\u3080\u5e45\u5e83\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306e\u4f7f\u7528\u306b\u3064\u3044\u3066\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u6e08\u307f\u3067\u3059\u3002<a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/primary-antibodies\/research-area-antibodies\/neurobiology-antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8a73\u3057\u3044\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p><strong>Invitrogen\u2122 Attune\u2122 NxT Flow Cytometer\uff1a\u30d1\u30ef\u30d5\u30eb\u3067\u30d5\u30ec\u30ad\u30b7\u30d6\u30eb<\/strong><\/p>\n<ul>\n<li>\u30e2\u30b8\u30e5\u30fc\u30eb\u5f0f\u30c7\u30b6\u30a4\u30f3\u0336\u30d5\u30a3\u30fc\u30eb\u30c9\u30a2\u30c3\u30d7\u30b0\u30ec\u30fc\u30c9\u5bfe\u5fdc\u306e\u591a\u69d8\u306a\u6a5f\u5668\u69cb\u6210\u3092\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u5bfe\u5fdc<\/li>\n<li>\u6240\u8981\u6642\u9593\u3092\u77ed\u7e2e\u0336\u30c7\u30fc\u30bf\u54c1\u8cea\u3092\u7dad\u6301\u3057\u305f\u307e\u307e10\u500d\u306b\u9ad8\u901f\u5316<\/li>\n<li>\u7c21\u6f54\u306a\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u0336\u6d17\u6d44\u4e0d\u8981\u30fb\u6eb6\u8840\u4e0d\u8981\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u3088\u308b\u76ee\u8a70\u307e\u308a\u9632\u6b62\u578b\u306e\u6d41\u4f53\u5de5\u5b66\u3092\u63a1\u7528<\/li>\n<li>\u30e6\u30fc\u30b6\u30fc\u72ec\u81ea\u306e\u7528\u9014\u306b\u5bfe\u5fdc\u0336\u3042\u3089\u3086\u308b\u7d30\u80de\u578b\u3068\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u8907\u96d1\u306a\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u5bfe\u5fdc<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-nxt-flow-cytometer.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8868\u73fe\u578b\u89e3\u6790\u306b\u304a\u3059\u3059\u3081\u306e\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fc\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h4>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u65b0\u3057\u3044\u6cbb\u7642\u6cd5<\/h4>\n<p>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u9032\u884c\u3092\u56de\u5fa9\u307e\u305f\u306f\u9045\u5ef6\u3055\u305b\u308b\u305f\u3081\u306e\u75be\u60a3\u4fee\u98fe\u6cbb\u7642\u306f\u73fe\u5728\u5b58\u5728\u3057\u307e\u305b\u3093\u3002\u65e2\u5b58\u306e\u6cbb\u7642\u306f\u3001\u8a8d\u77e5\u6a5f\u80fd\u4f4e\u4e0b\u3092\u9045\u5ef6\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u4e00\u6642\u7684\u306b\u75c7\u72b6\u3092\u6539\u5584\u3059\u308b\u3082\u306e\u3067\u3001\u795e\u7d4c\u7d42\u672b\u306e\u795e\u7d4c\u4f1d\u9054\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u306b\u7126\u70b9\u304c\u5f53\u3066\u3089\u308c\u3066\u3044\u307e\u3059\u30021\u3064\u306e\u85ac\u5264\u30af\u30e9\u30b9\u3067\u306f\u3001\u30a2\u30bb\u30c1\u30eb\u30b3\u30ea\u30f3\u5206\u89e3\u9175\u7d20\u3067\u3042\u308b\u30a2\u30bb\u30c1\u30eb\u30b3\u30ea\u30f3\u30a8\u30b9\u30c6\u30e9\u30fc\u30bc\uff08AChE\uff09\u306e\u963b\u5bb3\u3092\u4ecb\u3057\u3066\u795e\u7d4c\u7d42\u672b\u306e\u30a2\u30bb\u30c1\u30eb\u30b3\u30ea\u30f3\uff08ACh\uff09\u30ec\u30d9\u30eb\u3092\u5897\u52a0\u3055\u305b\u307e\u3059\uff08\u30b7\u30ca\u30d7\u30b9\u304b\u3089ACh\u3092\u653e\u51fa\u3055\u305b\u308b\u305f\u3081\u306e\u4e3b\u8981\u306a\u30e1\u30ab\u30cb\u30ba\u30e0\uff09\uff08\u56f33.11\uff09\u3002AD\u6cbb\u7642\u85ac\u3068\u3057\u3066FDA\u306b\u627f\u8a8d\u3055\u308c\u3066\u3044\u308bAChE\u963b\u5bb3\u85ac\u306f\u3001\u30ea\u30d0\u30b9\u30c1\u30b0\u30df\u30f3\u3001\u30c9\u30cd\u30da\u30b8\u30eb\u3001\u304a\u3088\u3073\u30ac\u30e9\u30f3\u30bf\u30df\u30f3\u306e3\u3064\u3067\u3059\u3002\u3055\u3089\u306b\u8fd1\u5e74\u3001NMDA\u53d7\u5bb9\u4f53\u62ee\u6297\u85ac\u3067\u3042\u308b\u30e1\u30de\u30f3\u30c1\u30f3\u304cAD\u6cbb\u7642\u85ac\u3068\u3057\u3066\u627f\u8a8d\u3055\u308c\u307e\u3057\u305f\uff08\u56f33.11\uff09\u3002\u30e1\u30de\u30f3\u30c1\u30f3\u306f\u3001\u30b0\u30eb\u30bf\u30df\u30f3\u9178\u8208\u596e\u6bd2\u6027\u3092\u6291\u5236\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u00a0<sup>*8\u00a0<\/sup>\u3002<\/p>\n<p>AD\u306e\u8a8d\u77e5\u75c7\u72b6\u306e\u6cbb\u7642\u306b\u5bfe\u3057\u3066\u627f\u8a8d\u3055\u308c\u3066\u3044\u308b\u6cbb\u7642\u85ac\u306e\u4f5c\u7528\u6a5f\u5e8f\u306f2\u7a2e\u985e\u3060\u3051\u3067\u3059\u304c\u3001\u6570\u591a\u304f\u306e\u6709\u671b\u306a\u5b9f\u9a13\u7684\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002AD\u306b\u5bfe\u3059\u308b\u5b9f\u9a13\u7684\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u4f8b\u3068\u3057\u3066\u306f\u3001\u4ee5\u4e0b\u306e\u6226\u7565\u2015\u30a2\u30df\u30ed\u30a4\u30c9\u03b2\u304a\u3088\u3073\u30bf\u30a6\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b\u85ac\u5264\u306e\u958b\u767a\u3001CNS\u306b\u304a\u3051\u308bROS\u3001\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3001\u304a\u3088\u3073\u708e\u75c7\u3092\u963b\u5bb3\u3059\u308b\u85ac\u5264\u306e\u958b\u767a\u3001\u306a\u3089\u3073\u306b \u795e\u7d4c\u4fdd\u8b77\u304a\u3088\u3073\u518d\u751f\u3092\u4fc3\u9032\u3059\u308b\u7d30\u80de\u30d9\u30fc\u30b9\u306e\u6cbb\u7642\u306e\u5b9f\u73fe\u53ef\u80fd\u6027\u306e\u8a55\u4fa1\u2015\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u73fe\u5728\u81e8\u5e8a\u8a66\u9a13\u4e2d\u306e\u4ee3\u8868\u7684\u306a\u85ac\u5264\u3092\u88683.8\u306b\u793a\u3057\u307e\u3059\u00a0<sup>*8,27,31,40-42<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-158.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3263 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-158.jpg\" alt=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u6cbb\u7642\u85ac\u3068\u3057\u3066\u958b\u767a\u3055\u308c\u3066\u3044\u308b\u4ee3\u8868\u7684\u306a\u85ac\u5264\u306e\u4f8b\" width=\"673\" height=\"524\" \/><\/a><\/p>\n<h4>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u5e79\u7d30\u80de\u30d9\u30fc\u30b9\u306e\u6cbb\u7642<\/h4>\n<p>AD\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u85ac\u5264\u304a\u3088\u3073\u5b9f\u9a13\u7684\u306a\u514d\u75ab\u7642\u6cd5\u6226\u7565\u306b\u52a0\u3048\u3066\u3001\u5e79\u7d30\u80de\u7814\u7a76\u5206\u91ce\u306f\u3053\u306e\u58ca\u6ec5\u7684\u306a\u75be\u60a3\u306b\u5bfe\u3057\u5207\u671b\u3055\u308c\u3066\u3044\u308b\u6cbb\u7642\u6cd5\u3092\u63d0\u4f9b\u3059\u308b\u3082\u306e\u3068\u3057\u3066\u975e\u5e38\u306b\u6709\u671b\u8996\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3067\u306f\u3001\u6280\u8853\u306e\u9032\u6b69\u306b\u3088\u308a\u3001\u9ad8\u7d14\u5ea6\u304b\u3064\u9ad8\u6fc3\u5ea6\u306e\u795e\u7d4c\u5e79\u7d30\u80de\u304a\u3088\u3073\u30b0\u30ea\u30a2\u5e79\u7d30\u80de\u306e\u751f\u7523\u304c\u53ef\u80fd\u3067\u3059\u3002\u795e\u7d4c\u5e79\u7d30\u80de\uff08NSC\uff09\u306f\u3001\u80ce\u5150\u8133\u7d44\u7e54\u3001\u65b0\u751f\u5150\u304a\u3088\u3073\u6210\u4eba\u306e\u6b7b\u5f8c\u8133\u7d44\u7e54\u3001\u80da\u6027\u5e79\u7d30\u80de\uff08ESC\uff09\u3001\u3042\u308b\u3044\u306f\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC\uff09\u306a\u3069\u306e\u6570\u591a\u304f\u306e\u30bd\u30fc\u30b9\u304b\u3089\u7372\u5f97\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u3052\u3063\u6b6f\u985e\u306e\u8a66\u9a13\u3067\u306f\u3001NSC\u79fb\u690d\u5f8c\u306b\u30b3\u30ea\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u5897\u52a0\u304a\u3088\u3073\u8a18\u61b6\u306e\u6539\u5584\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u3053\u306e\u6539\u5584\u306f\u3001\u79fb\u690d\u3055\u308c\u305fNSC\u304c\u65e2\u5b58\u306e\u7d44\u7e54\u306b\u7d44\u8fbc\u307e\u308c\u305f\u7d50\u679c\u304b\u3001NSC\u306e\u6804\u990a\u56e0\u5b50\u5206\u6ccc\u306b\u3088\u308b\u3082\u306e\u304b\u660e\u3089\u304b\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002AD\u30e9\u30c3\u30c8\u30e2\u30c7\u30eb\u3092\u7528\u3044\u305f\u4e00\u9023\u306e\u8a66\u9a13\u3067\u306f\u3001\u30d2\u30c8\u795e\u7d4c\u6210\u9577\u56e0\u5b50\u907a\u4f1d\u5b50\u3092\u767a\u73fe\u3057\u3066\u3044\u308b\u30e9\u30c3\u30c8NSC\u306f\u751f\u5b58\u3057\u3001\u5927\u8133\u76ae\u8cea\u306b\u7d44\u8fbc\u307e\u308c\u3001\u8a8d\u77e5\u884c\u52d5\u304c\u5897\u52a0\u3057\u307e\u3057\u305f\u304c\u3001\u30d2\u30c8NGF\u907a\u4f1d\u5b50\u3092\u542b\u307e\u306a\u3044NSC\u306f\u751f\u5b58\u305b\u305a\u3001\u5927\u8133\u76ae\u8cea\u306b\u7d44\u8fbc\u307e\u308c\u305a\u3001\u8a8d\u77e5\u6a5f\u80fd\u304c\u6539\u5584\u3057\u307e\u305b\u3093\u3067\u3057\u305f\u00a0<sup>*2<\/sup>\u3002<\/p>\n<p>\u524d\u81e8\u5e8a\u8a66\u9a13\u7528\u306e\u5e79\u7d30\u80de\u3092\u4f5c\u88fd\u304a\u3088\u3073\u5206\u96e2\u3059\u308b\u80fd\u529b\u306f\u3001\u65b0\u3057\u3044\u81e8\u5e8a\u6cbb\u7642\u3068\u3057\u3066\u5e79\u7d30\u80de\u3092\u7814\u7a76\u3059\u308b\u305f\u3081\u306e\u9053\u3092\u5207\u308a\u958b\u304d\u307e\u3059\u3002AD\u306b\u5bfe\u3059\u308b\u6700\u521d\u306e\u5e79\u7d30\u80de\u81e8\u5e8a\u8a66\u9a13\u306f\u6700\u8fd1\u958b\u59cb\u3055\u308c\uff08\u56f33.13\uff09\u3001\u6ce8\u5165\u3055\u308c\u305f\u5e79\u7d30\u80de\u306eMRI\u306b\u3088\u308b\u8ffd\u8de1\u306b\u6210\u529f\u3057\u305f\u4f8b\u3082\u3042\u308a\u307e\u3059\u3002AD\u60a3\u8005\u7531\u6765\u306e\u5e79\u7d30\u80de\u306f\u3001\u6709\u671b\u306aAD\u6cbb\u7642\u6cd5\u3068\u3057\u3066\u958b\u767a\u3055\u308c\u3066\u3044\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u65b0\u3057\u3044\u85ac\u7406\u7642\u6cd5\u3092\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3059\u308b\u305f\u3081\u306e\u5b9f\u9a13\u30e2\u30c7\u30eb\u3068\u3057\u3066\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*43<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-159.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3264 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-159.jpg\" alt=\"CD44\u6297\u4f53\u304a\u3088\u3073GFAP\u6297\u4f53\u3092\u7528\u3044\u305f\u30b0\u30ea\u30a2\u524d\u99c6\u7d30\u80de\u304a\u3088\u3073\u30a2 \u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306e\u514d\u75ab\u86cd\u5149\u5206\u6790\" width=\"399\" height=\"385\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3265 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-46.jpg\" alt=\"PSC\u304b\u3089in vitro\u3067\u8a98\u5c0e\u3057\u305f\u795e\u7d4c\u5e79\u7d30\u80de\u306e\u30ad\u30e3\u30e9\u30af\u30bf\u30ea \u30bc\u30fc\u30b7\u30e7\u30f3\" width=\"400\" height=\"713\" \/><\/p>\n<h4>\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u305f\u3081\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb<\/h4>\n<p>\u751f\u7269\u533b\u5b66\u7814\u7a76\u306e\u305f\u3081\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u7528\u306e\u9ad8\u54c1\u795e\u7d4c\u751f\u7269\u5b66\u304a\u3088\u3073\u4ed6\u306e\u7814\u7a76\u9818\u57df\u306e\u5206\u91ce\u306b\u304a\u3051\u308b\u65b0\u3057\u3044\u767a\u898b\u306b\u8ca2\u732e\u3057\u307e\u3059\u3002\u5f53\u793e\u3067\u306f\u3001ELISA\u30ad\u30c3\u30c8\u3001Luminex\u88c5\u7f6e\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0\u7528\u306e\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3001\u304a\u3088\u3073\u6297\u4f53\u30da\u30a2\u30ad\u30c3\u30c8\u306e\u5e45\u5e83\u3044\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u3092\u3001\u7c21\u4fbf\u3067\u3059\u3050\u306b\u4f7f\u3048\u308b\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306e\u63d0\u4f9b\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u306e\u305f\u3081\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u306e\u8cea\u306b\u95a2\u3059\u308b\u8a73\u3057\u3044\u60c5\u5831\u3001\u304a\u3088\u3073\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u30ac\u30a4\u30c9\u306e\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u306e\u30b5\u30a4\u30c8\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u5f53\u793e\u306eELISA\u30ad\u30c3\u30c8\u306f3,000\u4ef6\u4ee5\u4e0a\u306e\u8ad6\u6587\u3067\u53c2\u7167\u3055\u308c\u3066\u304a\u308a\u3001\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u306f1,000\u4ef6\u3092\u8d85\u3048\u308b\u8ad6\u6587\u306b\u5f15\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u3067\u306f\u3001\u9ad8\u611f\u5ea6\u3067\u7279\u7570\u7684\u306a\u3001\u7d30\u80de\u5185\u307e\u305f\u306f\u7d30\u80de\u5916\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u691c\u51fa\u306e\u305f\u3081\u306b\u3001\u5e83\u7bc4\u56f2\u306a\u514d\u75ab\u30d9\u30fc\u30b9\u306e\u88fd\u54c1\u3092\u3001\u7c21\u4fbf\u3067\u3059\u3050\u306b\u4f7f\u3048\u308b\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u3067\u306f\u3001\u5358\u4e00\u5206\u6790\u7269\u306e\u89e3\u6790\u7528\u306e\u6297\u4f53\u30da\u30a2\u30ad\u30c3\u30c8\u304a\u3088\u3073ELISA\u30ad\u30c3\u30c8\u3001\u3055\u3089\u306b\u8907\u6570\u30bf\u30fc\u30b2\u30c3\u30c8\u540c\u6642\u89e3\u6790\u7528\u306e\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u30a2\u30c3\u30bb\u30a4\u3092\u958b\u767a \u3057\u307e\u3057\u305f\u3002\u5f53\u793e\u306e\u30ad\u30c3\u30c8\u306f\u3001\u611f\u5ea6\u3001\u7279\u7570\u6027\u3001\u7cbe\u5ea6\u3001\u304a\u3088\u3073\u30ed\u30c3\u30c8\u9593\u306e\u4e00\u8cab\u6027\u306a\u3069\u306e\u57fa\u6e96\u306b\u95a2\u3057\u3066\u53b3\u683c\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30d7\u30ed\u30bb\u30b9\u3092\u901a\u904e\u3057\u3066\u304a\u308a\u3001\u4fe1\u983c\u6027\u306e\u3042\u308b\u6b63\u78ba\u306a\u7d50\u679c\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u304a\u3088\u3073\u4ed6\u306e\u9818\u57df\u306e\u751f\u7269\u533b\u5b66\u7814\u7a76\u306b\u306f\u3001Invitrogen\u2122\u304a\u3088\u3073Thermo Scientific\u2122\u306e\u30a4\u30e0\u30ce\u30a2\u30c3\u30bb\u30a4\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays\/elisa-kits.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u65b0\u3057\u3044\u30ac\u30a4\u30c9\u306b\u5fc5\u8981\u3068\u3059\u308b\u88fd\u54c1\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u306a\u304f\u3066\u3082\u5fc3\u914d\u3054\u7121\u7528\u3067\u3059\u3002\u0336\u5f53\u793e\u306f\u3001\u5e45\u5e83\u3044\u30ab\u30b9\u30bf\u30e0\u88fd\u54c1\u958b\u767a\u30b5\u30fc\u30d3\u30b9\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5185\u5bb9\u3092\u542b\u3080PDF\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p>\uff5e\u4e3b\u306a\u5185\u5bb9\uff5e<\/p>\n<ol>\n<li>\u30a4\u30f3\u30c8\u30ed\u30c0\u30af\u30b7\u30e7\u30f3<\/li>\n<li>\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u304a\u3051\u308b\u5171\u901a\u306e\u30c6\u30fc\u30de<\/li>\n<li>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f<\/li>\n<li>\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3<\/li>\n<li>\u6297\u4f53\uff1a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb<\/li>\n<\/ol>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<p><span style=\"font-size: 8pt\">\u53c2\u8003\u6587\u732e\uff1a<br \/>\n1. Stages of Alzheimer\u2019s. alz.org. http:\/\/www.alz.org\/alzheimers_disease_stages_of_alzheimers.asp. Accessed August 2015.<br \/>\n2. Tong LM, Fong H, Huang Y (2015) Stem cell therapy for Alzheimer\u2019s disease\u00a0and related disorders: current status and future perspectives. Exp Mol Med\u00a013;47:e151.<br \/>\n3. Bird TD. Alzheimer Disease Overview. 1998 [Updated 2014 Apr 3]. In:\u00a0GeneReviews [Internet]. Pagon RA, Adam MP, Ardinger HH, et al., editors.\u00a0Seattle (WA): University of Washington, Seattle; 1993-2015. Available from:\u00a0http:\/\/www.ncbi.nlm.nih.gov\/books\/NBK1161\/. Accessed August 2015.<br \/>\n4. 2015 Alzheimer\u2019s Disease Facts and Figures. Alzheimer\u2019s association. https:\/\/www.alz.org\/facts\/downloads\/facts_figures_2015.pdf. Accessed August 2015.<br \/>\n5. Sheng M, Sabatini BL, S\u00fcdhof TC (2012) Synapses and Alzheimer\u2019s disease.\u00a0Cold Spring Harb Perspect Biol 1;4(5).<br \/>\n6. Ray M, Zhang W (2010) Analysis of Alzheimer\u2019s disease severity across brain\u00a0regions by topological analysis of gene co-expression networks. BMC Syst Biol\u00a04:136.<br \/>\n7. Moreira PI, Carvalho C, Zhu X et al. (2010) Mitochondrial dysfunction is a trigger\u00a0of Alzheimer\u2019s disease pathophysiology. Biochim Biophys Acta 1802(1):2\u201310.<br \/>\n8. Guzior N, Wieckowska A, Panek D et al. (2015) Recent development of\u00a0multifunctional agents as potential drug candidates for the treatment of\u00a0Alzheimer\u2019s disease. Curr Med Chem 22(3):373\u2013404.<br \/>\n9. Collingwood J Brain Fluid Changes Predict Alzheimer\u2019s 10 Years in Advance.\u00a0Psych Central. http:\/\/psychcentral.com\/lib\/brain-fluid-changes-predictalzheimers-10-years-in-advance\/. Accessed August 2015.<br \/>\n10. Gendelman HE, Anantharam V, Bronich T et al. (2015) Nanoneuromedicines\u00a0for degenerative, inflammatory, and infectious nervous system diseases.\u00a0Nanomedicine 11(3):751\u2013767.<br \/>\n11. 2015 Alzheimer\u2019s Statistics. Alzheimers.net. http:\/\/www.alzheimers.net\/resources\/alzheimers-statistics\/. Accessed September 2015.<br \/>\n12. 2015 Alzheimer\u2019s Statistics. Alzheimers.net. http:\/\/www.alz.org\/dementia\/typesof-dementia.asp. Accessed August 2015.<br \/>\n13. Alzheimer\u2019s Disease Fact Sheet. National Institute on Aging. https:\/\/www.nia.nih.gov\/alzheimers\/publication\/alzheimers-disease-fact-sheet. Accessed August\u00a02015.<br \/>\n14. Lott IT, Head E (2005) Alzheimer disease and Down syndrome: factors in\u00a0pathogenesis. Neurobiol Aging. 2005 Mar;26(3):383\u2013389.<br \/>\n15. Barber RC (2012) The genetics of Alzheimer\u2019s disease. Scientifica (Cairo)\u00a02012:246210.<br \/>\n16. Risk Factors. Alz.org. http:\/\/www.alz.org\/alzheimers_disease_causes_risk_factors.asp. Accessed August 2015.<br \/>\n17. Serrano-Pozo A, Frosch MP, Masliah E (2011) Neuropathological alterations in\u00a0Alzheimer disease. Cold Spring Harb Perspect Med 1(1):a006189.<br \/>\n18. Apostolova LG, Green AE, Babakchanian S et al. (2012) Hippocampal atrophy\u00a0and ventricular enlargement in normal aging, mild cognitive impairment (MCI),\u00a0and Alzheimer Disease. Alzheimer Dis Assoc Disord 26(1):17\u201327.<br \/>\n19. Rosso AB, Inestrosa NC (2013) WNT signaling in neuronal maturation and\u00a0synaptogenesis. Front Cell Neurosci 7:103.<br \/>\n20. Pescosolido N, Pascarella A, Buomprisco G et al. (2014) Critical review on the\u00a0relationship between glaucoma and Alzheimer\u2019s disease. Adv Ophthalmol Vis\u00a0Syst 1(4):00024.<br \/>\n21. Zhang X, Li Y, Xu H et al. (2014) The -secretase complex: from structure to\u00a0function. Front Cell Neurosci 8:427.<br \/>\n22. Querfurth HW, LaFerla FM (2010) Alzheimer\u2019s disease. N Engl J Med\u00a0362(4):329\u2013344.<br \/>\n23. Sakono M, Zako T (2010) Amyloid oligomers: formation and toxicity of Abeta\u00a0oligomers. FEBS J 277(6):1348\u20131358.<br \/>\n24. Goure WF, Krafft GA, Jerecic J (2014) Targeting the proper amyloid-beta\u00a0neuronal toxins: a path forward for Alzheimer\u2019s disease immunotherapeutics. Alzheimers Res Ther 6(4):42.<br \/>\n25. Anoop A, Singh PK, Jacob RS et al. (2010) CSF biomarkers for Alzheimer\u2019s\u00a0disease diagnosis. Int J Alzheimers Dis 23;2010:606802.<br \/>\n26. Mandelkow E, Mandelkow EM (1995) Microtubules and microtubule-associated\u00a0proteins. Curr Opin Cell Biol 7(1):72\u201381.<br \/>\n27. Boutajangout A, Wisniewsik T (2014) Tau-based therapeutic approaches for\u00a0Alzheimer\u2019s disease &#8211; a mini-review. Gerontology. 2014;60(5):381\u2013385.<br \/>\n28. Wang JZ, Xia YY, Grundke-Iqbal I et al. (2013) Abnormal hyperphosphorylation\u00a0of tau: sites, regulation, and molecular mechanism of neurofibrillary\u00a0degeneration. J Alzheimers Dis 33 Suppl 1:S123\u2013S139.<br \/>\n29. Wischik CM, Harrington CR, Storey JM (2014) Tau-aggregation inhibitor therapy\u00a0for Alzheimer\u2019s disease. Biochem Pharmacol 88(4):529\u2013539.<br \/>\n30. Aso E, Ferrer I (2013) Potential Therapeutic Strategies to Prevent Progression of\u00a0Alzheimer to Disease States. Chapter 11 in: Understanding Alzheimer\u2019s Disease.\u00a0Intech http:\/\/cdn.intechopen.com\/pdfs-wm\/43125.pdf. Accessed August 2015.<br \/>\n31. Kumar A, Singh A, Ekavi AS (2015) A review on Alzheimer\u2019s disease\u00a0pathophysiology and its management: an update. Pharmacol Rep 67(2):195\u2013203.<br \/>\n32. Puntmann VO (2009) How-to guide on biomarkers: biomarker definitions,\u00a0validation and applications with examples from cardiovascular disease. Postgrad\u00a0Med J 85(1008):538\u2013545.<br \/>\n33. Heppner FL, Ransohoff RM, Becher B. (2015) Immune attack: the role of\u00a0inflammation in Alzheimer disease. Nat Rev Neurosci 16(6):358\u2013372.<br \/>\n34. Heneka MT, Carson MJ, El Khoury J et al. (2015) Neuroinflammation in\u00a0Alzheimer\u2019s disease. Lancet Neurol 14(4):388\u2013405.<br \/>\n35. Morales I, Guzm\u00e1n-Mart\u00ednez L, Cerda-Troncoso C et al. (2014)\u00a0Neuroinflammation in the pathogenesis of Alzheimer\u2019s disease. A rational\u00a0framework for the search of novel therapeutic approaches. Front Cell Neurosci\u00a022;8:112.<br \/>\n36. Marques F, Sousa JC, Sousa N et al. (2013) Blood-brain-barriers in aging and in\u00a0Alzheimer\u2019s disease. Mol Neurodegener 22;8:38.<br \/>\n37. Li Y, Tan MS, Jiang T et al. (2014) Microglia in Alzheimer\u2019s disease. Biomed Res\u00a0Int 2014:437483.<br \/>\n38. Yang C, Xiao S (2015) New developments of clinical trial in immunotherapy\u00a0for Alzheimer\u2019s disease. Curr Pharm Biotech16(6):484\u2013491. http:\/\/www.ingentaconnect.com\/content\/ben\/cpb\/2015\/00000016\/00000006\/art00002?token=00431021437a63736a6f35475f4c7a763c24452a5b6f644a467b4d616d3f4e4b342. Accessed August 2015.<br \/>\n39. Wisniewski T, Go i F (2015) Immunotherapeutic approaches for Alzheimer\u2019s\u00a0disease. Neuron 18;85(6):1162\u20131176.<br \/>\n40. Han SH, Mook-Jung I (2014) Diverse molecular targets for therapeutic strategies\u00a0in Alzheimer\u2019s disease. J Korean Med Sci 29:893\u2013902.<br \/>\n41. Kang JH, Ryoo NY, Shin DW et al. (2014) Role of cerebrospinal fluid biomarkers\u00a0in clinical trials for Alzheimer\u2019s disease modifying therapies. Korean J Physiol\u00a0Pharmacol 18(6):447\u2013456.<br \/>\n42. Jia Q, Deng Y, Qing H et al. (2014) Potential therapeutic strategies for\u00a0Alzhiemer\u2019s disease targeting or beyond -amyloid: insights from clinical trials.\u00a0BioMed Res Int 837157<br \/>\n43. ALZFORUM\/Networking for a Cure. Ready or Not: Stem Cell Therapies Poised\u00a0to Enter Trials for Alzheimer\u2019s. http:\/\/www.alzforum.org\/news\/conferencecoverage\/ready-or-not-stem-cell-therapies-poised-enter-trials-alzheimers.\u00a0Accessed August 2015.<br \/>\n<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f \u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u306f\u3001\u8a18\u61b6\u304a\u3088\u3073\u884c\u52d5\u306b\u304a\u3051\u308b\u9032\u884c\u6027\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0*1,2 \u3002\u3053\u308c\u306f\u8a8d\u77e5\u75c7\u306e\u4e2d\u3067\u6700\u3082\u591a\u304f\u307f\u3089\u308c\u308b\u5f62\u614b\u3067\u3001\u767a\u75c5\u306f\u4e00\u822c\u7684\u306b\u5b64\u767a\u6027\u3067\u3001\u975e\u5e38\u306b\u591a\u304f\u306e\u74b0\u5883\u7684\u304a\u3088\u3073\u907a\u4f1d<\/p>\n","protected":false},"author":988,"featured_media":4324,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[32],"division":[],"class_list":{"0":"post-1097","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-antibody","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064\" \/>\n<meta property=\"og:description\" content=\"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f \u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u306f\u3001\u8a18\u61b6\u304a\u3088\u3073\u884c\u52d5\u306b\u304a\u3051\u308b\u9032\u884c\u6027\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0*1,2 \u3002\u3053\u308c\u306f\u8a8d\u77e5\u75c7\u306e\u4e2d\u3067\u6700\u3082\u591a\u304f\u307f\u3089\u308c\u308b\u5f62\u614b\u3067\u3001\u767a\u75c5\u306f\u4e00\u822c\u7684\u306b\u5b64\u767a\u6027\u3067\u3001\u975e\u5e38\u306b\u591a\u304f\u306e\u74b0\u5883\u7684\u304a\u3088\u3073\u907a\u4f1d\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-12-20T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-28T02:09:22+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"830\" \/>\n\t<meta property=\"og:image:height\" content=\"429\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"54\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064\",\"datePublished\":\"2018-12-20T00:00:00+00:00\",\"dateModified\":\"2025-02-28T02:09:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/\"},\"wordCount\":1176,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-1.png\",\"keywords\":[\"\u6297\u4f53\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/\",\"name\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-1.png\",\"datePublished\":\"2018-12-20T00:00:00+00:00\",\"dateModified\":\"2025-02-28T02:09:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-1.png\",\"width\":830,\"height\":429,\"caption\":\"\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064","og_description":"\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f \u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\uff08AD\uff09\u306f\u3001\u8a18\u61b6\u304a\u3088\u3073\u884c\u52d5\u306b\u304a\u3051\u308b\u9032\u884c\u6027\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0*1,2 \u3002\u3053\u308c\u306f\u8a8d\u77e5\u75c7\u306e\u4e2d\u3067\u6700\u3082\u591a\u304f\u307f\u3089\u308c\u308b\u5f62\u614b\u3067\u3001\u767a\u75c5\u306f\u4e00\u822c\u7684\u306b\u5b64\u767a\u6027\u3067\u3001\u975e\u5e38\u306b\u591a\u304f\u306e\u74b0\u5883\u7684\u304a\u3088\u3073\u907a\u4f1d","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-12-20T00:00:00+00:00","article_modified_time":"2025-02-28T02:09:22+00:00","og_image":[{"width":830,"height":429,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","type":"image\/png"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"54\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064","datePublished":"2018-12-20T00:00:00+00:00","dateModified":"2025-02-28T02:09:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/"},"wordCount":1176,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","keywords":["\u6297\u4f53"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/","name":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","datePublished":"2018-12-20T00:00:00+00:00","dateModified":"2025-02-28T02:09:22+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","width":830,"height":429,"caption":"\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30462\u3011\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u3072\u307f\u3064"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":32,"label":"\u6297\u4f53"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png",760,393,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":32,"name":"\u6297\u4f53","slug":"antibody","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":31,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":1097,"position":0},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":1097,"position":1},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":1097,"position":2},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":1097,"position":3},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":1097,"position":4},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":1097,"position":5},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1097","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1097"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1097\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4324"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1097"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1097"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1097"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}