{"id":1124,"date":"2018-12-21T00:00:00","date_gmt":"2018-12-20T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/"},"modified":"2023-12-27T17:47:05","modified_gmt":"2023-12-27T08:47:05","slug":"neuro_disease3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/","title":{"rendered":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3"},"content":{"rendered":"\n<p>1\u3064\u306e\u795e\u7d4c\u5909\u6027\u75c7\u72b6\u3092\u4ed6\u306e\u660e\u78ba\u306b\u7570\u306a\u308b\u75c7\u72b6\u3068\u8b58\u5225\u3057\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u5883\u754c\u7dda\u306f\u3088\u304f\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u304a\u3088\u3073\u904b\u52d5\u6a5f\u80fd\u969c\u5bb3\u306e\u60a3\u8005\u306f\u3001\u9ad8\u983b\u5ea6\u30671\u3064\u4ee5\u4e0a\u306e\u660e\u78ba\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u795e\u7d4c\u5b66\u7684\u75c5\u72b6\u304c\u7591\u308f\u308c\u3001\u307e\u305f\u8907\u6570\u306e\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u306e\u5b58\u5728\u306f\u795e\u7d4c\u5b66\u7684\u969c\u5bb3\u306e\u5897\u52a0\u3068\u95a2\u4fc2\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u30b1\u30fc\u30b9\u306b\u3088\u3063\u3066\u306f\u3001\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u3067\u691c\u51fa\u3055\u308c\u305f\u75c7\u4f8b\u306b\u660e\u767d\u306a\u969c\u5bb3\u306e\u5146\u5019\u304c\u898b\u3089\u308c\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u72b6\u6cc1\u306b\u304a\u3044\u3066\u3001\u6c7a\u5b9a\u7684\u306a\u75be\u60a3\u5206\u985e\u3092\u78ba\u7acb\u3059\u308b\u3053\u3068\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u8a3a\u65ad\u3001\u6cbb\u7642\u3001\u304a\u3088\u3073\u7814\u7a76\u306b\u304a\u3051\u308b\u8ab2\u984c\u3067\u3059\u3002<\/p>\n<p>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3001\u30ec\u30d3\u30fc\u5c0f\u4f53\u578b\u8a8d\u77e5\u75c7\u3001\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u3001\u304a\u3088\u3073\u4ed6\u306e\u75c7\u72b6\u306a\u3069\u306e\u69d8\u3005\u306a\u75c7\u5019\u7fa4\u306e\u9593\u306b\u306f\u3001\u9ad8\u983b\u5ea6\u306b\u30aa\u30fc\u30d0\u30fc\u30e9\u30c3\u30d7\u304c\u5b58\u5728\u3059\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u3053\u306e\u75be\u60a3\u30b0\u30eb\u30fc\u30d7\u3092\u5b9a\u7fa9\u3059\u308b\u305f\u3081\u306b\u4f1d\u7d71\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u660e\u78ba\u306a\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u306f\u3001\u7814\u7a76\u8005\u304c\u795e\u7d4c\u6bd2\u6027\u304a\u3088\u3073\u795e\u7d4c\u5909\u6027\u306b\u5bc4\u4e0e\u3059\u308b\u767a\u75c7\u6a5f\u5e8f\u306e\u89e3\u660e\u3092\u59cb\u3081\u308b\u3053\u3068\u3092\u53ef\u80fd\u3068\u3059\u308b\u30d5\u30ec\u30fc\u30e0\u30ef\u30fc\u30af\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u203b<span style=\"text-decoration: underline\">\u672c\u8a18\u4e8b\u306e\u672b\u5c3e\u306b\u304a\u3044\u3066\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u3064\u3044\u3066\u4f53\u7cfb\u7684\u306b\u5b66\u3079\u308b\u7121\u6599\u30b3\u30f3\u30c6\u30f3\u30c4\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002<\/span><\/p>\n<h2>\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5<\/h2>\n<h4>\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u306e\u7279\u5fb4<\/h4>\n<p>\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\uff08PD\uff09\u306f\u3001\u904b\u52d5\u6a5f\u80fd\u4e0d\u5168\u3092\u7279\u5fb4\u3068\u3059\u308b\u9032\u884c\u6027\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u3067\u3059 *<sup>1<\/sup> \u3002PD\u306f\u3001\u30d1\u30fc\u30ad\u30f3\u30bd\u30cb\u30ba\u30e0\u306e\u6700\u3082\u4e00\u822c\u7684\u306a\u5f62\u614b\u3067\u3001\u7b4b\u632f\u6226\u304a\u3088\u3073\u7b4b\u56fa\u7e2e\u3001\u52d5\u4f5c\u7de9\u6162\u3001\u59ff\u52e2\u306e\u4e0d\u5b89\u5b9a\u3001\u306a\u3089\u3073\u306b\u6b69\u884c\u969c\u5bb3\u306b\u3088\u3063\u3066\u7279\u5fb4\u4ed8\u3051\u3089\u308c\u308b\u5168\u3066\u306e\u81e8\u5e8a\u969c\u5bb3\u3092\u5305\u542b\u3057\u307e\u3059\u3002PD\u3092\u767a\u75c7\u3057\u305f\u60a3\u8005\u306e5\u4eba\u306b1\u4eba\u306f\u8a8d\u77e5\u75c7\u3082\u767a\u75c7\u3057\u307e\u3059\u3002\u5b64\u767a\u6027PD\u306e\u75c7\u72b6\u306f\u4e00\u822c\u7684\u306b60\u6b73\u524d\u5f8c\u3067\u767a\u75c7\u3057\u307e\u3059\u304c\u3001\u82e5\u5e74\u767a\u75c7\u8005\u306f\u3053\u306e\u75be\u60a3\u306e\u907a\u4f1d\u578b\u3092\u6301\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002PD\u306f\u3001\u975e\u5bfe\u79f0\u6027\u56db\u80a2\u786c\u76f4\u3084\u30ec\u30dc\u30c9\u30d1\uff08L-3,4-\u30b8\u30d2\u30c9\u30ed\u30ad\u30b7\u30d5\u30a7\u30cb\u30eb\u30a2\u30e9\u30cb\u30f3\uff1bL-DOPA\uff09\u306b\u3088\u308b\u6cbb\u7642\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u306a\u3069\u306e\u81e8\u5e8a\u6240\u898b\u306b\u57fa\u3065\u3044\u3066\u8a3a\u65ad\u3055\u308c\u307e\u3059\u30022,3 L-DOPA\u307e\u305f\u306f\u30c9\u30fc\u30d1\u30df\u30f3\u30a2\u30b4\u30cb\u30b9\u30c8\u306b\u3088\u308b\u6cbb\u7642\u306b\u3088\u308a \u904b\u52d5\u75c7\u72b6\u306f\u6539\u5584\u3055\u308c\u307e\u3059\u304c\u3001\u75be\u60a3\u9032\u884c\u3092\u5909\u5316\u3055\u305b\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\uff08\u56f34.1\uff09\u3002\u75be\u60a3\u306e\u7d4c\u904e\u306b\u304a\u3044\u3066\u3001\u5927\u90e8\u5206\u306e\u60a3\u8005\u306f\u3001\u4e7e\u766c\u3001\u6291\u3046\u3064\u75c7\u72b6\u3001\u8a8d\u77e5\u75c7\u3001\u81ea\u5f8b\u795e\u7d4c\u969c\u5bb3\u3001\u7761\u7720\u969c\u5bb3\u3001\u304a\u3088\u3073\u75bc\u75db\u306a\u3069\u306e\u975e\u904b\u52d5\u6027\u306e\u75c7\u72b6\u3092\u7d4c\u9a13\u3057\u307e\u3059\u00a0<sup>*1\u00a0<\/sup>\u3002<\/p>\n<h4>PD\u306e\u907a\u4f1d\u5b50\u5909\u7570\u4f53<\/h4>\n<p>\u5927\u90e8\u5206\u306ePD\u60a3\u8005\u306f\u5b64\u767a\u6027\u75be\u60a3\u3067\u3059\u304c\u3001\u308f\u305a\u304b10\uff05\u306e\u60a3\u8005\u306b\u306f\u5bb6\u65cf\u6b74\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u7d0420\u5e74\u9593\u306e\u7814\u7a76\u306b\u3088\u3063\u3066\u3001\u512a\u6027\u307e\u305f\u306f\u52a3\u6027\u306e\u907a\u4f1d\u5f62\u5f0f\u3092\u6301\u3064\u6570\u7a2e\u306ePD\u306e\u5358\u4e00\u907a\u4f1d\u5b50\u5f62\u614b\u304c\u767a\u898b\u3055\u308c\u307e\u3057\u305f\u3002PD\u306f\u3001PD\u3068\u306e\u95a2\u9023\u6027\u3092\u793a\u3059PARK\u3068\u547c\u3070\u308c\u308b\u7279\u5b9a\u306e\u907a\u4f1d\u5b50\u5ea7\u306b\u57fa\u3065\u3044\u3066\u5206\u985e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5358\u4e00\u907a\u4f1d\u5b50\u6027\u306ePD\u3067\u306f\u3001\uff16\u7a2e\u985e\u306e\u907a\u4f1d\u5b50\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3046\u3061\u3001SNCA\uff08PARK1\uff09\u304a\u3088\u3073LRRK2\uff08PARK8\uff09\u306f\u3001\u3044\u305a\u308c\u3082\u5e38\u67d3\u8272\u4f53\u512a\u6027\u306e\u907a\u4f1d\u5f62\u5f0f\u3092\u793a\u3057\u3001parkin\uff08PARK2\uff09\u3001PINK1\uff08PARK6\uff09\u3001DJ-1\uff08PARK7\uff09\u3001\u304a\u3088\u3073ATP13A2\uff08PARK9\uff09\u306f\u3001\u52a3\u6027\u306e\u907a\u4f1d\u5f62\u5f0f\u3092\u793a\u3057\u307e\u3059\uff08\u88684.1\uff09 *<sup>4-6<\/sup>\u00a0\u3002 \u4ed6\u306e\u907a\u4f1d\u5b50\u306f\u3001PD\u767a\u75c7\u306e\u5358\u72ec\u306e\u8981\u56e0\u3068\u306f\u306a\u308a\u307e\u305b\u3093\u304c\u3001PD\u3092\u767a\u75c7\u3055\u305b\u308b\u30ea\u30b9\u30af\u3092\u5897\u52a0\u3055\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001GBA1\u907a\u4f1d\u5b50\u306f\u30ea\u30bd\u30bd\u30fc\u30e0\u30b0\u30eb\u30b3\u30bb\u30ec\u30d6\u30ed\u30b7\u30c0\u30fc\u30bc\u3092\u30b3\u30fc\u30c9\u3057\u307e\u3059\u304c\u3001GBA\u907a\u4f1d\u5b50\u306b\u304a\u3051\u308b\u5909\u7570\u306f\u5b64\u767a\u6027PD\u306e\u767a\u75c7\u30ea\u30b9\u30af\u306e\u5897\u52a0\u306b\u95a2\u9023\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u6a5f\u80fd\u3092\u4f4e\u4e0b\u3055\u305b\u307e\u3059\u00a0<sup>*4,7,8\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-160.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3269 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-160.jpg\" alt=\"PD\u3078\u306e\u95a2\u4e0e\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u308b\u5358\u4e00\u907a\u4f1d\u5b50PARK\" width=\"399\" height=\"925\" \/><\/a><\/p>\n<h4>PD\u306e\u9855\u8457\u306a\u7279\u5fb4<\/h4>\n<p>\u6570\u591a\u304f\u306e\u69d8\u3005\u306a\u75be\u60a3\u304cPD\u3068\u5171\u901a\u3059\u308b\u7279\u5fb4\u3092\u6301\u3061\u307e\u3059\u304c\u3001\u5b64\u767a\u6027PD\u306b\u95a2\u9023\u3059\u308b\u91cd\u8981\u306a\u7279\u5fb4\u306f\u9ed2\u8cea\u306b\u304a\u3051\u308b\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u55aa\u5931\u3068\u30ec\u30d3\u30fc\u5c0f\u4f53\u306e\u5b58\u5728\u3001\u4e3b\u306b\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u304b\u3089\u306a\u308b\u7d30\u80de\u8cea\u5185\u51dd\u96c6\u4f53\u3067\u3059\u00a0<sup>*2<\/sup> \u3002PD\u60a3\u8005\u7531\u6765\u306e\u6b7b\u5f8c\u8133\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u514d\u75ab\u53cd\u5fdc\u6027\u304c\u7d30\u80de\u4f53\u304a\u3088\u3073\u4e0d\u6eb6\u6027\u7dda\u7dad\u3068\u3057\u3066\u306e\u795e\u7d4c\u7a81\u8d77\u3092\u901a\u3057\u3066\u78ba\u8a8d\u3055\u308c\u3001\u305d\u308c\u305e\u308c\u30ec\u30d3\u30fc\u5c0f\u4f53\u304a\u3088\u3073\u30ec\u30d3\u30fc\u795e\u7d4c\u7a81\u8d77\u3068\u3057\u3066\u53ef\u8996\u5316\u3055\u308c\u307e\u3057\u305f\u3002\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u51dd\u96c6\u306f\u3001PD\u60a3\u8005\u306e\u5e83\u7bc4\u56f2\u306e\u8133\u9818\u57df\u3067\u691c\u51fa\u3055\u308c\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u304a\u3088\u3073\u30ec\u30d3\u30fc\u5c0f\u4f53\u578b\u8a8d\u77e5\u75c7\u306a\u3069\u306e\u4ed6\u306e\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u75c5\u306b\u3082\u5b58\u5728\u3057\u307e\u3059<sup>*9,10<\/sup>\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-161.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3270 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-161.jpg\" alt=\"\u9ed2\u8cea\" width=\"367\" height=\"253\" \/><\/a> <a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-47.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3271 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-47.jpg\" alt=\"\u30ec\u30d3\u30fc\u5c0f\u4f53\" width=\"404\" height=\"374\" \/><\/a><\/p>\n<h4>\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3<\/h4>\n<p>\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306f\u3001\u30db\u30b9\u30db\u30ea\u30d1\u30fc\u30bcD2\u3092\u963b\u5bb3\u3059\u308b\u795e\u7d4c\u30b7\u30ca\u30d7\u30b9\u524d\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3001SNCA\u907a\u4f1d\u5b50\uff08PARK1\u907a\u4f1d\u5b50\u5ea7\uff09\u306b\u30b3\u30fc\u30c9\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306b\u5bfe\u3059\u308b\u6297\u4f53\u306f\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u304c\u30ec\u30d3\u30fc\u5c0f\u4f53\u306e\u4e3b\u8981\u6210\u5206\u3067\u3042\u308b\u3053\u3068\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002<sup>*9,11<\/sup> \u91ce\u751f\u578b\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306f\u7dda\u7dad\u51dd\u96c6\u4f53\u3092\u5f62\u6210\u3057\u3001\u591a\u304f\u306e\u69d8\u3005\u306a\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u5909\u7570\u4f53\u306f\u3001\u5897\u5f37\u3055\u308c\u305f\u30ec\u30d3\u30fc\u5c0f\u4f53\u5f62\u6210\u80fd\u3092\u793a\u3057\u307e\u3059\u00a0<sup>*12<\/sup> \u3002\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u907a\u4f1d\u5b50\u306e\u904e\u5270\u306a\u30b3\u30d4\u30fc\u3084\u7279\u5b9a\u306e\u30df\u30b9\u30bb\u30f3\u30b9\u5909\u7570\uff08A53T\u304a\u3088\u3073A30P\uff09\u306f\u5bb6\u65cf\u6027PD\u306e\u65e9\u671f\u767a\u75c7\u306b\u95a2\u4fc2\u3057\u307e\u3059\u00a0<sup>*12<\/sup> \u3002\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u30df\u30b9\u30d5\u30a9\u30fc\u30eb\u30c7\u30a3\u30f3\u30b0\u306f\u3001\u91ce\u751f\u578b\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u904e\u5270\u767a\u73fe\u3001\u91ce\u751f\u578b\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u767a\u73fe\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u3001\u306a\u3089\u3073\u306b\u9178\u5316\u7684\u30b9\u30c8\u30ec\u30c3\u30b5\u30fc\u304a\u3088\u3073\u708e\u75c7\u306b\u5bfe\u3059\u308b\u53cd\u5fdc\u3068\u3057\u3066\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u8fd1\u5e74\u306e\u7814\u7a76\u3067\u306f\u3001\u30c1\u30ed\u30b7\u30f3\u30ad\u30ca\u30fc\u30bcc-Abl\u306e\u30ec\u30d9\u30eb\u304a\u3088\u3073\u6d3b\u6027\u306e\u5897\u52a0\u304c\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u84c4\u7a4d\u306e\u5897\u52a0\u3092\u5c0e\u3044\u3066\u3044\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u3002c-Abl\u963b\u5bb3\u85ac\u3067\u3042\u308b\u30cb\u30ed\u30c1\u30cb\u30d6\uff08FDA\u627f\u8a8d\u6e08\u307f\u306e\u6162\u6027\u9aa8\u9ac4\u6027\u767d\u8840\u75c5\u6cbb\u7642\u85ac\uff09\u306f\u3001PD\u30de\u30a6\u30b9\u30e2\u30c7\u30eb\u306b\u304a\u3044\u3066\u795e\u7d4c\u4fdd\u8b77\u4f5c\u7528\u304a\u3088\u3073\u30c9\u30fc\u30d1\u30df\u30f3\u30ec\u30d9\u30eb\u306e\u56de\u5fa9\u4f5c\u7528\u3092\u793a\u3057\u307e\u3057\u305f\u00a0<sup>*13,14\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-162.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3272 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-162.jpg\" alt=\"\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u6297\u4f53\" width=\"810\" height=\"280\" \/><\/a><\/p>\n<h4>\u75c5\u614b\u751f\u7406\u5b66<\/h4>\n<p>\u91ce\u751f\u578b\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306f\u3001\u30b7\u30ca\u30d7\u30b9\u4f1d\u9054\u306e\u8abf\u7bc0\u304a\u3088\u3073\u795e\u7d4c\u7d42\u672b\u304b\u3089\u306e\u795e\u7d4c\u4f1d\u9054\u7269\u8cea\u306e\u653e\u51fa\u306b\u95a2\u4e0e\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*15<\/sup> \u3002\u307e\u305f\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306f\u795e\u7d4c\u4fdd\u8b77\u306e\u5f79\u5272\u3082\u62c5\u3063\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u3092\u767a\u73fe\u3055\u305b\u3001\u30b7\u30e3\u30da\u30ed\u30f3\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3042\u308b\u30b7\u30b9\u30c6\u30a4\u30f3-\u30b9\u30c8\u30ea\u30f3\u30b0-\u30bf\u30f3\u30d1\u30af\u8cea-\u03b1\uff08CSP\u03b1\uff09\u3092\u6b20\u640d\u3055\u305b\u305f\u30c8\u30e9\u30f3\u30b9\u30b8\u30a7\u30cb\u30c3\u30af\u30de\u30a6\u30b9\u3067\u306f\u3001\u795e\u7d4c\u5909\u6027\u306e\u65e9\u671f\u767a\u75c7\u304a\u3088\u3073\u795e\u7d4c\u7d30\u80de\u6b7b\u304b\u3089\u30ec\u30b9\u30ad\u30e5\u30fc\u3055\u308c\u307e\u3057\u305f\u3002\u53cd\u5bfe\u306b\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u30e2\u30c7\u30eb\u3067\u306f\u3001CSP\u03b1\u5a92\u4ecb\u795e\u7d4c\u5909\u6027\u304c\u60aa\u5316\u3057\u307e\u3057\u305f\u00a0<sup>*16\u00a0<\/sup>\u3002\u91ce\u751f\u578b\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306f\u795e\u7d4c\u4fdd\u8b77\u4f5c\u7528\u3092\u6709\u3059\u308b\u3068\u3055\u308c\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u51dd\u96c6\u306f\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u5909\u6027\u306b\u95a2\u4fc2\u3057\u3001\u6700\u7d42\u7684\u306b\u7121\u6570\u306e\u904b\u52d5\u795e\u7d4c\u306e\u5f8c\u907a\u75c7\u3092\u5f15\u304d\u8d77\u3053\u3059\u3068\u3044\u3046\u6570\u591a\u304f\u306e\u30a8\u30d3\u30c7\u30f3\u30b9\u304c\u5b58\u5728\u3057\u307e\u3059\u00a0<sup>*17<\/sup>\u3002<br \/>\n\u5909\u7570\u304a\u3088\u3073\u74b0\u5883\u56e0\u5b50\u306f\u3001\u30aa\u30ea\u30b4\u30de\u30fc\u3092\u5f62\u6210\u3059\u308b\u30df\u30b9\u30d5\u30a9\u30fc\u30eb\u30c9\u3057\u305f\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7523\u751f\u3092\u5c0e\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7570\u5e38\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u84c4\u7a4d\u3057\u3001\u6b63\u5e38\u306a\u30ea\u30bd\u30bd\u30fc\u30e0\u304a\u3088\u3073\u30d7\u30ed\u30c6\u30a2\u30bd\u30fc\u30e0\u306e\u9664\u53bb\u6a5f\u69cb\u3092\u56de\u907f\u3057\u307e\u3059\u3002\u03b1-\u30b7\u30cc\u30af\u30ec\u30a4\u30f3\u306e\u51dd\u96c6\u306f\u3001\u9178\u5316\u30b9\u30c8\u30ec\u30b9\u3092\u8a98\u5c0e\u3057\u3001\u8ef8\u7d22\u8f38\u9001\u3092\u969c\u5bb3\u3057\u3001\u30b7\u30ca\u30d7\u30b9\u6a5f\u80fd\u969c\u5bb3\u3092\u8d77\u3053\u3057\u3001\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u6a5f\u80fd\u4e0d\u5168\u3092\u4fc3\u9032\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u75be\u60a3\u306e\u9032\u884c\u306f\u3001\u90e8\u5206\u7684\u306b\u3001\u30df\u30b9\u30d5\u30a9\u30fc\u30eb\u30c9\u3057\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u30cb\u30e5\u30fc\u30ed\u30f3\u304b\u3089\u30cb\u30e5\u30fc\u30ed\u30f3\u3078\u3068\u5e83\u304c\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\uff08\u56f34.2\uff09\u00a0<sup>*10\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-163.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3273 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-163.jpg\" alt=\"\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u306b\u95a2\u4e0e\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9078\u629e\" width=\"402\" height=\"428\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-164.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3274 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-164.jpg\" alt=\"\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u306e\u9032\u884c\u306b\u95a2\u4e0e\u3059\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\" width=\"821\" height=\"390\" \/><\/a><\/p>\n<h4>\u65e2\u5b58\u306e\u6cbb\u7642\u6cd5<\/h4>\n<p>PD\u306b\u95a2\u9023\u3059\u308b\u904b\u52d5\u75c7\u72b6\u306f\u3001\u9ed2\u8cea\u306b\u304a\u3051\u308b\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u55aa\u5931\u304c\u539f\u56e0\u3067\u3059\u3002\u65e2\u5b58\u306e\u6cbb\u7642\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u591a\u304f\u306f\u3001\u30c9\u30fc\u30d1\u30df\u30f3\u795e\u7d4c\u4f1d\u9054\u306e\u5897\u5f37\u3092\u76ee\u6a19\u3068\u3057\u3066\u3044\u307e\u3059\uff08\u8868.3\uff09\u00a0<sup>*18<\/sup> \u3002\u3053\u306e\u3088\u3046\u306a\u6226\u7565\u306f\u975e\u5e38\u306b\u52b9\u679c\u7684\u3067\u3059\u304c\uff08\u7279\u306b\u75be\u60a3\u767a\u75c7\u6642\uff09\u3001\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u3001\u3053\u308c\u3089\u306e\u6cbb\u7642\u6cd5\u306f\u4e00\u9023\u306e\u904b\u52d5\u6027\u306e\u526f\u4f5c\u7528\u3092\u4f34\u3044\u307e\u3059\u3002\u307e\u305f\u3001PD\u306e\u9032\u884c\u306b\u4f34\u3044\u3001\u975e\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\u306e\u904b\u52d5\u75c7\u72b6\u304a\u3088\u3073\u975e\u904b\u52d5\u75c7\u72b6\u304c\u9855\u8457\u306b\u306a\u3063\u3066\u304d\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u5c06\u6765\u306ePD\u6cbb\u7642\u6cd5\u306e\u63a2\u7d22\u306f\u3001\u795e\u7d4c\u4fdd\u8b77\u304a\u3088\u3073\u75be\u60a3\u4fee\u98fe\u3092\u6226\u7565\u3068\u3057\u307e\u3059\u00a0<sup>*19\u00a0<\/sup>\u3002<\/p>\n<h4>\u5b9f\u9a13\u7684\u6cbb\u7642<\/h4>\n<p>\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u306e\u65b0\u3057\u3044\u6cbb\u7642\u6226\u7565\u3068\u3057\u3066\u306f\u3001\u708e\u75c7\u3001\u9178\u5316\u3001\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3001\u304a\u3088\u3073\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30df\u30b9\u30d5\u30a9\u30fc\u30eb\u30c7\u30a3\u30f3\u30b0\/\u51dd\u96c6\u306a\u3069\u306e\u75be\u60a3\u30d7\u30ed\u30bb\u30b9\u306e\u963b\u5bb3\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u6cbb\u7642\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3064\u3044\u3066\u306f\u3001PD\u306e\u75be\u60a3\u4fee\u98fe\u7642\u6cd5\u3068\u3057\u3066\u63a2\u7d22\u3055\u308c\u3066\u304d\u3066\u3044\u308b\u304b\u3001\u73fe\u5728\u63a2\u7d22\u4e2d\u3067\u3059\u304c\u3001\u5e79\u7d30\u80de\u3092\u4f7f\u7528\u3057\u305f\u65b0\u3057\u3044\u6280\u8853\u3092\u7528\u3044\u308b\u6cbb\u7642\u6cd5\u306e\u4e00\u90e8\u3067\u306f\u81e8\u5e8a\u8a66\u9a13\u304c\u958b\u59cb\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30ea\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u56e0\u5b50\u306e\u7570\u6240\u6027\u767a\u73fe\u3092\u4ecb\u3057\u3066\u60a3\u8005\u306e\u6210\u719f\u7d30\u80de\u7531\u6765\u306e\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\uff08iPSC\uff09\u3092\u4f5c\u88fd\u3059\u308b\u80fd\u529b\u306f\u3001\u5e79\u7d30\u80de\u7814\u7a76\u306b\u5909\u9769\u3092\u3082\u305f\u3089\u3057\u3066\u3044\u307e\u3059 *<sup>20<\/sup> \u3002\u5c06\u6765\u7684\u306b\u306f\u3001\u60a3\u8005\u7531\u6765iPSC\u3092\u795e\u7d4c\u5909\u6027\u75be\u60a3\u30e2\u30c7\u30eb\u3084\u6cbb\u7642\u85ac\u306e\u958b\u767a\u306b\u4f7f\u7528\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001PD\u60a3\u8005\u306b\u5bfe\u3059\u308b\u7d30\u80de\u30d9\u30fc\u30b9\u306e\u7642\u6cd5\u3068\u3057\u3066\u306e\u958b\u767a\u306e\u53ef\u80fd\u6027\u3082\u79d8\u3081\u3066\u3044\u307e\u3059\u00a0<sup>*19,21-22\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-165.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3275 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-165.jpg\" alt=\"\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u306e\u65e2\u5b58\u306e\u6cbb\u7642\u6cd5\" width=\"401\" height=\"378\" \/><\/a><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u306e\u6297\u4f53\u30d9\u30fc\u30b9\u30c4\u30fc\u30eb\u306e\u5e45\u5e83\u3044\u30dd\u30fc\u30c8\u30d5\u30a9\u30ea\u30aa\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5<\/h2>\n<h4>\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306e\u7279\u5fb4<\/h4>\n<p>\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\uff08HD)\u306f\u3001\u9032\u884c\u6027\u3067\u3001\u901a\u5e38\u907a\u4f1d\u6027\u306e\u3001\u5178\u578b\u7684\u306a\u4e09\u5927\u75c7\u72b6\u3092\u7279\u5fb4\u3068\u3059\u308b\u795e\u7d4c\u5909\u6027\u75be\u60a3\u3067\u3059\uff08\u88684.4\uff09<sup>*23<\/sup> \u3002\u75c7\u72b6\u306e\u5e73\u5747\u767a\u75c7\u5e74\u9f62\u306f\u7d0435\uff5e44\u6b73\u3067\u3059\u304c\u300110\uff05\u306e\u75c7\u4f8b\u3067\u306f\u5e7c\u5150\u671f\u306b\u767a\u75c7\u3057\u307e\u3059\u00a0<sup>*24,25<\/sup> \u3002\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306e\u751f\u5b58\u671f\u9593\u306e\u4e2d\u592e\u5024\u306f\u4e00\u822c\u7684\u306b\u306f\u767a\u75c7\u5e74\u304b\u308915\uff5e18\u5e74\u3067\u3059\u00a0<sup>*27<\/sup> \u3002\u73fe\u5728\u3001HD\u306e\u9032\u884c\u3092\u9045\u5ef6\u307e\u305f\u306f\u505c\u6b62\u3055\u305b\u308b\u6cbb\u7642\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u00a0<sup>*28<\/sup> \u3002\u672c\u75be\u60a3\u306e\u81ea\u7136\u7d4c\u904e\u306b\u306f\u3001\u660e\u3089\u304b\u306a\u75be\u60a3\u306b\u5148\u884c\u3057\u3066\u5fae\u5999\u306a\u5909\u5316\u3092\u6765\u305f\u3059\u201c\u524d\u99c6\u201d\u6bb5\u968e\u3082\u5b58\u5728\u3057\u307e\u3059\u3002\uff08\u56f34.3\uff09\u00a0<sup>*25\u00a0<\/sup>\u3002<\/p>\n<p>\u7814\u7a76\u306e\u91cd\u8981\u306a\u65b0\u9818\u57df\u306e1\u3064\u306f\u3001\u524d\u99c6\u6bb5\u968e\u306b\u304a\u3051\u308b\u5fae\u5999\u306a\u5909\u5316\u3092\u691c\u51fa\u3059\u308b\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u540c\u5b9a\u3067\u3059\u3002\u65e9\u671f\u306e\u533b\u7642\u4ecb\u5165\u306b\u3064\u306a\u304c\u308a\u3001\u5275\u85ac\u52aa\u529b\u3092\u524d\u9032\u3055\u305b\u308b\u65e9\u671f\u767a\u898b\u3092\u53ef\u80fd\u3068\u3057\u3001\u3055\u3089\u306b\u75be\u60a3\u9032\u884c\u306e\u8ffd\u8de1\u3082\u53ef\u80fd\u3068\u3059\u308b\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u958b\u767a\u306f\u6025\u52d9\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306f\u3001\u65e9\u671f\u533b\u7642\u4ecb\u5165\u306e\u305f\u3081\u306e\u6cbb\u7642\u6cd5\u306e\u63d0\u6848\u3092\u53ef\u80fd\u3068\u3057\u307e\u3059\u00a0<sup>*26\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-167.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3277 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-167.jpg\" alt=\"\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u7528\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\" width=\"419\" height=\"309\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-166.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3276 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-166.jpg\" alt=\"\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306e\u4e09\u5927\u75c7\u72b6\/\u7279\u6027\/\u7279\u5fb4\" width=\"401\" height=\"521\" \/><\/a><\/p>\n<h4>HD\u306e\u539f\u56e0<\/h4>\n<p>HD\u306e\u907a\u4f1d\u578b\u306f\u5e38\u67d3\u8272\u4f53\u512a\u6027\u907a\u4f1d\u5f62\u5f0f\u3092\u793a\u3059\u305f\u3081\u30011\u3064\u306e\u7570\u5e38\u306a\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\u907a\u4f1d\u5b50\uff08HTT\uff09\u30a2\u30ec\u30eb\u304c\u53d7\u3051\u7d99\u304c\u308c\u305f\u5b50\u5b6b\u306b\u3053\u306e\u75be\u60a3\u304c\u767a\u73fe\u3057\u307e\u3059\u3002\u5b64\u767a\u6027\uff08\u975e\u907a\u4f1d\u6027\uff09\u306eHD\u75c7\u4f8b\u306f\u7a00\u3067\u30015\uff5e8\uff05\u306eHD\u75c7\u4f8b\u306b\u307f\u3089\u308c\u307e\u3059\u00a0<sup>*25<\/sup> \u3002HD\u306f\u3001HTT\u907a\u4f1d\u5b50\u9818\u57df\u3092\u30b3\u30fc\u30c9\u3059\u308bN\u672b\u7aef\u306b\u5b58\u5728\u3059\u308bCAG\u30ea\u30d4\u30fc\u30c8\u306e\u7570\u5e38\u4f38\u9577\u3092\u539f\u56e0\u3068\u3059\u308bCAG\u30ea\u30d4\u30fc\u30c8\u75c5\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002CAG\u30ea\u30d4\u30fc\u30c8\u306f\u3001\u30dd\u30eaQ\u4f38\u9577\u3068\u547c\u3070\u308c\u308b\u9023\u7d9a\u3059\u308b\u30b0\u30eb\u30bf\u30df\u30f3\uff08Q\uff09\u6b8b\u57fa\u3092\u30b3\u30fc\u30c9\u3057\u307e\u3059\u3002\u305d\u306e\u9577\u3055\u306f\u75be\u60a3\u306e\u6d78\u900f\u7387\u3068\u75c5\u539f\u6027\u3092\u6c7a\u5b9a\u3057\u307e\u3059\uff08\u56f34.4\uff09<sup>*23,25<\/sup> \u3002\u767a\u75c5\u306b\u81f3\u308b\u4f38\u9577\u3092\u3057\u305fCAG\u30a2\u30ec\u30eb\u306f\u3001\u795e\u7d4c\u7d30\u80de\u6b7b\u3092\u5f15\u304d\u8d77\u3053\u3059\u795e\u7d4c\u6bd2\u6027\u3092\u6301\u3064\u65ad\u7247\u5316\u3055\u308c\u305f\u51dd\u96c6\u4f53\u3092\u5f62\u6210\u3059\u308b\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u7523\u751f\u3059\u308b\u6a5f\u80fd\u7372\u5f97\u578b\u5909\u7570\u3068\u3057\u3066\u4f5c\u7528\u3057\u307e\u3059\u00a0<sup>*25\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-168.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3278 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-168.jpg\" alt=\"HTT\u907a\u4f1d\u5b50\u4e2d\u306eCAG\u30ea\u30d4\u30fc\u30c8\" width=\"416\" height=\"219\" \/><\/a><\/p>\n<h4>\u75c5\u614b\u751f\u7406\u5b66<\/h4>\n<p>\u5e83\u7bc4\u56f2\u306b\u308f\u305f\u308b\u795e\u7d4c\u640d\u50b7\u304a\u3088\u3073\u76ae\u8cea\u5909\u6027\u306f\u3001\u8a8d\u77e5\u969c\u5bb3\u304a\u3088\u3073\u4eba\u683c\u5909\u5316\u306e\u4e3b\u306a\u539f\u56e0\u3067\u3059\u3002\u5927\u8133\u57fa\u5e95\u6838\u0336\u7279\u306b\u3001\u6de1\u84bc\u7403\uff08GPe\u304a\u3088\u3073GPi\u30cb\u30e5\u30fc\u30ed\u30f3\uff09\u306a\u3089\u3073\u306b\u7dda\u6761\u4f53\u0336\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u55aa\u5931\u306f\u3001\u821e\u8e0f\u75c5\u306e\u4e3b\u306a\u539f\u56e0\u3067\u3059\u00a0<sup>*29,30<\/sup> \u3002\u7dda\u6761\u4f53\u306b\u304a\u3051\u308b\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u55aa\u5931\u306f\u3001\u904b\u52d5\u6a5f\u80fd\u3092\u5236\u5fa1\u3059\u308b\uff12\u3064\u306e\u76ae\u8cea-\u7dda\u6761\u4f53-\u8996\u5e8a\u56de\u8def\uff08\u76ae\u8cea\u2192\u7dda\u6761\u4f53\u2192\u8996\u5e8a\uff09\u3092\u969c\u5bb3\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u56de\u8def\uff08\u76f4\u63a5\u8def\u304a\u3088\u3073\u9593\u63a5\u8def\uff09\u306f\u3001\u904b\u52d5\u76ae\u8cea\u306b\u4fe1\u53f7\u3092\u9001\u308b\u8996\u5e8a\u3067\u5408\u6d41\u3057\u307e\u3059\u3002\u30d1\u30fc\u30ad\u30f3\u30bd\u30f3\u75c5\u3068\u306f\u5bfe\u7167\u7684\u306b\u3001\u9ed2\u8cea\u306e\u30c9\u30fc\u30d1\u30df\u30f3\u4f5c\u52d5\u6027\u30cb\u30e5\u30fc\u30ed\u30f3\u306f\u5f71\u97ff\u3092\u53d7\u3051\u306a\u3044\u305f\u3081\u3001\u5b9f\u969b\u3001HD\u60a3\u8005\u306e\u7dda\u6761\u4f53\u306b\u304a\u3051\u308b\u30c9\u30fc\u30d1\u30df\u30f3\u30ec\u30d9\u30eb\u306f\u6b63\u5e38\u5024\u3088\u308a\u9ad8\u3044\u3067\u3059\u00a0<sup>*31<\/sup> \u3002\u30c9\u30fc\u30d1\u30df\u30f3\u30ec\u30d9\u30eb\u306e\u4e0a\u6607\u306f\u821e\u8e0f\u75c5\u306b\u3082\u5bc4\u4e0e\u3057\u307e\u3059\u3002<\/p>\n<p>\u7d30\u80de\u5185\u3067\u3001\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\u306f\u3001\u5b8c\u5168\u9577\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u3057\u3066\u3082\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u3084\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u7531\u6765\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u65ad\u7247\u3068\u3057\u3066\u3082\u5b58\u5728\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u65ad\u7247\u306e\u5f62\u6210\u0336\u7279\u306b\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\u306e\u6700\u521d\u306e100\u30a2\u30df\u30ce\u9178\u3092\u542b\u3080N\u672b\u7aef\u65ad\u7247\uff08\u4f8b\uff1aHTT\u30a8\u30ad\u30bd\u30f31\u30e2\u30ce\u30de\u30fc\uff09\u0336\u306f\u3001\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306e\u75c5\u614b\u5f62\u6210\u306b\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002\u5909\u7570\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\uff08mHtt\uff09\u51dd\u96c6\u4f53\u306f\u3001\u30cb\u30e5\u30fc\u30ed\u30f3\u907a\u4f1d\u5b50\u306e\u8ee2\u5199\u3001\u8ef8\u7d22\u8f38\u9001\u3001\u304a\u3088\u3073\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u6a5f\u80fd\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\uff08\u56f34.5\uff09\u3002\u30dd\u30eaQ\u62e1\u5f35\u306f\u3001\u81ea\u5df1\u51dd\u96c6\u3092\u6bd2\u6027\u5f62\u614b\u306b\u4fc3\u9032\u3055\u305b\u308b\u3053\u308c\u3089\u306e\u65ad\u7247\u306b\u4ee3\u308f\u308b\u30b3\u30f3\u30d5\u30a9\u30e1\u30fc\u30b7\u30e7\u30f3\u3092\u3082\u305f\u3089\u3059\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u00a0<sup>*25<\/sup> \u3002\u30dd\u30eaQ\u62e1\u5f35\u306fN\u672b\u7aef\u65ad\u7247\u3068\u3001\u795e\u7d4c\u7d30\u80de\u306b\u304a\u3051\u308b\u5c0f\u80de\u8f38\u9001\u306e\u5f79\u5272\u3092\u62c5\u3046\u30cf\u30f3\u30c1\u30f3\u30c1\u30f3\u76f8\u4e92\u4f5c\u7528\u30bf\u30f3\u30d1\u30af\u8cea1 (HIP-1\uff09\u306e\u3088\u3046\u306a\u7d50\u5408\u30d1\u30fc\u30c8\u30ca\u30fc\u3084mHtt\u306b\u3088\u3063\u3066\u8abf\u7bc0\u4e0d\u5168\u3055\u308c\u308b\u4ed6\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u306e\u4ed5\u65b9\u3082\u5909\u5316\u3055\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\uff08\u88684.5\uff09<sup>*25<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-169.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3279 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-169.jpg\" alt=\"HD\u306e\u9032\u884c\u306b\u304a\u3051\u308b\u5909\u7570HTT\u306e\u5f79\u5272\" width=\"402\" height=\"804\" \/><\/a><\/p>\n<h4>\u30bf\u30fc\u30b2\u30c3\u30c8\u304a\u3088\u3073\u6709\u671b\u306a\u6cbb\u7642\u85ac<\/h4>\n<p>\u65e2\u5b58\u306e\u6cbb\u7642\u306f\u3001\u75be\u60a3\u3092\u4e88\u9632\u307e\u305f\u306f\u9045\u5ef6\u3055\u305b\u308b\u3088\u308a\u3082\u3001\u75c7\u72b6\u306e\u91cd\u7be4\u5ea6\u3092\u8efd\u6e1b\u3055\u305b\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30b7\u30ca\u30d7\u30b9\u5c0f\u80de\u30a2\u30df\u30f3\u30c8\u30e9\u30f3\u30b9\u30dd\u30fc\u30bf\u30fc\u963b\u5bb3\u5264\u304b\u3064\u30c9\u30fc\u30d1\u30df\u30f3\u7d4c\u8def\u963b\u5bb3\u5264\u3067\u3042\u308b\u30c6\u30c8\u30e9\u30d9\u30ca\u30b8\u30f3\u306f\u3001\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306b\u4f34\u3046\u821e\u8e0f\u904b\u52d5\u306b\u5bfe\u3059\u308b\u552f\u4e00\u306eFDA\u627f\u8a8d\u85ac\u3067\u3059\u00a0<sup>*25<\/sup> \u3002HD\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u6cbb\u7642\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u958b\u767a\u306e\u4e00\u74b0\u3068\u3057\u3066\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u540c\u5b9a\u306f\u3001HD\u306e\u5b58\u5728\u304a\u3088\u3073\u91cd\u7be4\u5ea6\u306e\u8a55\u4fa1\u3092\u53ef\u80fd\u3068\u3057\u3001\u85ac\u5264\u306e\u6d3b\u6027\u304a\u3088\u3073\u526f\u4f5c\u7528\u306b\u95a2\u3059\u308b\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u3001\u7121\u75c7\u72b6\u671f\u307e\u305f\u306f\u524d\u99c6\u671f\u306e\u671f\u9593\u306b\u75be\u60a3\u3092\u4e88\u6e2c\u3059\u308b\u30de\u30fc\u30ab\u30fc\u3092\u540c\u5b9a\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306f\u6cbb\u7642\u306e\u305f\u3081\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3082\u540c\u5b9a\u3057\u307e\u3059\u3002\u65e2\u5b58\u306e\u6709\u671b\u306a\u65b0\u3057\u3044\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306f\u3001HD\u60a3\u8005\u304a\u3088\u3073\u5bfe\u7167\u7fa4\u306e\u500b\u4f53\u9593\u306e\u8a8d\u77e5\u7684\u3001\u96fb\u6c17\u751f\u7406\u5b66\u7684\u3001\u89e3\u5256\u5b66\u7684\u3001\u751f\u5316\u5b66\u7684\u3001\u3042\u308b\u3044\u306f\u5206\u5b50\u7684\u306a\u3001\u81e8\u5e8a\u7279\u6027\u306e\u9055\u3044\u3092\u691c\u51fa\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001HD\u60a3\u8005\u306eCSF\u3067\u306fIL-6\u3001IL-8\u3001\u304a\u3088\u3073TNF-\u03b1\u306a\u3069\u306e\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u30ec\u30d9\u30eb\u306e\u4e0a\u6607\u304c\u307f\u3089\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001HD\u60a3\u8005\u306e\u7279\u5b9a\u306e\u767d\u8840\u7403\u3067\u306f\u8102\u80aa\u9178\u30a2\u30df\u30c9\u52a0\u6c34\u5206\u89e3\u9175\u7d20\u3084\u4ed6\u306e\u56e0\u5b50\u306e\u30ec\u30d9\u30eb\u306e\u6e1b\u5c11\u304c\u307f\u3089\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u00a0<sup>*25,32<\/sup> \u3002\u65b0\u3057\u3044\u6cbb\u7642\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3001\u6bd2\u6027\u3092\u6301\u3064Htt\u30bf\u30f3\u30d1\u30af\u8cea\u51dd\u96c6\u4f53\u306e\u5b9a\u5e38\u72b6\u614b\u30ec\u30d9\u30eb\u306e\u6e1b\u5c11\u3084\u3001mHtt\u51dd\u96c6\u4f53\u306b\u3088\u3063\u3066\u969c\u5bb3\u3055\u308c\u308b\u7d30\u80de\u30d7\u30ed\u30bb\u30b9\u306e\u8abf\u7bc0\u3092\u76ee\u7684\u3068\u3057\u3066\u958b\u767a\u4e2d\u3067\u3059\u3002\u57fa\u790e\u7814\u7a76\/\u524d\u81e8\u5e8a\u6bb5\u968e\u306e\u3053\u308c\u3089\u306e\u6226\u7565\u306e\u4ee3\u8868\u7684\u306a\u6982\u8981\u3092\u88684.6\u306b\u793a\u3057\u307e\u3059\u00a0<sup>*31,33,34\u00a0<\/sup>\u3002<\/p>\n<h4>\u5e79\u7d30\u80de\u30d9\u30fc\u30b9\u306e\u6cbb\u7642<\/h4>\n<p>\u65b0\u3057\u3044\u6cbb\u7642\u6226\u7565\u306b\u52a0\u3048\u3066\u3001\u3053\u308c\u3089\u306e\u6700\u5148\u7aef\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u306f\u3001\u5185\u5728\u6027\u5e79\u7d30\u80de\u306e\u7279\u5b9a\u306e\u30bf\u30a4\u30d7\uff08\u4f8b\uff1a\u9593\u8449\u7cfb\u5e79\u7d30\u80de\uff09\u3092\u4f7f\u7528\u3057\u305f\u308a\u3001\u30d2\u30c8\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\u3084\u30d2\u30c8\u80da\u6027\u5e79\u7d30\u80de\u682a\u3092\u6d3b\u7528\u3057\u307e\u3059\u3002\u6700\u7d42\u76ee\u6a19\u306f\u30011\uff09\u6b63\u5e38\u306a\u8133\u56de\u8def\u306e\u518d\u751f\u3092\u76ee\u7684\u3068\u3057\u3066\u79fb\u690d\u3059\u308b\u305f\u3081\u306eiPSC\u307e\u305f\u306fhESC\u5e79\u7d30\u80de\u306e\u7279\u5b9a\u306e\u795e\u7d4c\u7d30\u80de\u30bf\u30a4\u30d7\u307e\u305f\u306f\u30b0\u30ea\u30a2\u7d30\u80de\u30bf\u30a4\u30d7\u3078\u306e\u5206\u5316\u3001\u3042\u308b\u3044\u306f2\uff09BDNF\u306a\u3069\u306e\u795e\u7d4c\u6804\u990a\u56e0\u5b50\u306e\u52b9\u7387\u7684\u306a\u30bd\u30fc\u30b9\u3068\u3057\u3066\u306e\u5e79\u7d30\u80de\u306e\u4f7f\u7528\u3067\u3059\u00a0<sup>*35\u00a0<\/sup>\u3002<\/p>\n<p>\u7b2c1\u306e\u76ee\u6a19\u306e\u305f\u3081\u306e\u91cd\u8981\u8981\u4ef6\u306f\u3001\u88ab\u9a13\u8005\u306b\u79fb\u690d\u3059\u308b\u305f\u3081\u306b\u3001\u5e79\u7d30\u80de\u3092\u3001\u660e\u78ba\u306b\u5b9a\u7fa9\u3055\u308c\u3001\u9ad8\u5ea6\u306b\u7d14\u5316\u3055\u308c\u305f\u7cfb\u5217\u6c7a\u5b9a\u6e08\u307f\u7d30\u80de\u307e\u305f\u306f\u5206\u5316\u7d30\u80de\u306e\u96c6\u56e3\u306b\u5206\u5316\u3055\u305b\u308b\u80fd\u529b\u3067\u3059\u3002\u3053\u306e\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u30012\u3064\u306e\u88dc\u5b8c\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3088\u3063\u3066\u3001\u56fa\u6709\u306e\u907a\u4f1d\u5b50\u30b5\u30a4\u30f3\u3084\u907a\u4f1d\u5b50\u767a\u73fe\u30d1\u30bf\u30fc\u30f3\u306b\u57fa\u3065\u3044\u3066\u3001\u5e79\u7d30\u80de\u3001\u524d\u99c6\u4f53\u3001\u304a\u3088\u3073\u5206\u5316\u3057\u305f\u795e\u7d4c\u7d30\u80de\u307e\u305f\u306f\u30b0\u30ea\u30a2\u7d30\u80de\u306e\u7279\u6027\u6c7a\u5b9a\u304a\u3088\u3073\u5206\u985e\u3092\u884c\u3044\u307e\u3059\u3002\u30d7\u30ed\u30c6\u30aa\u30fc\u30e0\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u30b5\u30a4\u30f3\u3092\u691c\u51fa\u3057\u307e\u3059\u304c\u3001\u7d30\u80de\u8868\u9762\u30de\u30fc\u30ab\u30fc\u304a\u3088\u3073\u6804\u990a\/\u5206\u5316\u56e0\u5b50\u3092\u540c\u5b9a\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u3067\u304d\u308b\u70b9\u3067\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u30a2\u30d7\u30ed\u30fc\u30c1\u3088\u308a\u3082\u52b9\u7387\u7684\u3067\u3059\u00a0<sup>*35\u00a0<\/sup>\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3280 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-170.jpg\" alt=\"\u30cf\u30f3\u30c1\u30f3\u30c8\u30f3\u75c5\u306b\u5bfe\u3059\u308b\u6cbb\u7642\u85ac\" width=\"400\" height=\"385\" \/><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u4fc3\u9032\u3059\u308b\u6297\u4f53\u30d9\u30fc\u30b9\u306e\u30c4\u30fc\u30eb\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><\/p>\n<h2>\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7<\/h2>\n<h4>\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7\u306e\u7279\u5fb4<\/h4>\n<p>\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7\uff08ALS\uff09\u306f\u3001\u30eb\u30fc\u30fb\u30b2\u30fc\u30ea\u30c3\u30af\u75c5\u3068\u3082\u547c\u3070\u308c\u3001\u8133\u304a\u3088\u3073\u810a\u9ac4\u306e\u904b\u52d5\u30cb\u30e5\u30fc\u30ed\u30f3\u304c\u4fb5\u3055\u308c\u307e\u3059\u3002ALS\u306f\u3001\u6210\u4eba\u5f8c\u306b\u767a\u75c7\u3059\u308b\u6700\u3082\u4e00\u822c\u7684\u306a\u904b\u52d5\u30cb\u30e5\u30fc\u30ed\u30f3\u75be\u60a3\u3067\u30013\u756a\u76ee\u306b\u4e00\u822c\u7684\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u3067\u3059\u00a0<sup>*36<\/sup> \u3002ALS\u306e\u75c7\u72b6\u306b\u306f\u3001\u53cd\u5c04\u306e\u5909\u5316\u3001\u7b4b\u529b\u4f4e\u4e0b\u3001\u7b4b\u8089\u306e\u840e\u7e2e\u3001\u6523\u7e2e\u3001\u304a\u3088\u3073\u75d9\u6523\u304c\u3042\u308a\u307e\u3059\u3002ALS\u306f\u3001\u4e00\u822c\u7684\u306b\u7d0460\u6b73\u3067\u767a\u75c7\u3057\u30011\u3064\u306e\u7b4b\u8089\u30b5\u30d6\u30bb\u30c3\u30c8\u306b\u304a\u3044\u3066\u5f90\u3005\u306b\u75c7\u72b6\u304c\u59cb\u307e\u308a\u3001\u4ed6\u306e\u7b4b\u8089\u30b0\u30eb\u30fc\u30d7\u306b\u6d3e\u751f\u3057\u3066\u3044\u304d\u307e\u3059\u00a0<sup>*37<\/sup> \u300280\uff05\u306e\u75c7\u4f8b\u306b\u304a\u3044\u3066\u810a\u9ac4\u306b\u767a\u75c7\u3057\u3001\u975e\u5bfe\u79f0\u6027\u3067\u7121\u75db\u306e\u56db\u80a2\u306e\u7b4b\u529b\u4f4e\u4e0b\u304c\u751f\u3058\u307e\u3059\u00a0<sup>*37<\/sup> \u3002\u307e\u305f\u300120\uff05\u306e\u75c7\u4f8b\u306b\u304a\u3044\u3066\u5480\u56bc\u3001\u56a5\u4e0b\u3001\u304a\u3088\u3073\u767a\u58f0\u3092\u53f8\u308b\u9854\u9762\u306e\u5ef6\u9ac4\u7b4b\u306b\u767a\u75c7\u3057\u307e\u3059\u3002ALS\u60a3\u8005\u306f\u3001\u75c7\u72b6\u306e\u767a\u75c7\u5f8c\u3001\u5e73\u57473\u5e74\u751f\u5b58\u3057\u307e\u3059\u304c\u3001\u751f\u5b58\u671f\u9593\u306b\u306f\u9855\u8457\u306a\u3070\u3089\u3064\u304d\u3082\u3042\u308a\u307e\u3059\u00a0<sup>*41<\/sup> \u3002\u6b7b\u4ea1\u539f\u56e0\u306f\u3001\u901a\u5e38\u3001\u547c\u5438\u56f0\u96e3\u304a\u3088\u3073\u547c\u5438\u306e\u904b\u52d5\u5236\u5fa1\u969c\u5bb3\u3067\u3059\u00a0<sup>*41\u3002<\/sup> ALS\u3067\u306f\u3001\u904b\u52d5\u7cfb\u306e\u969c\u5bb3\u306b\u52a0\u3048\u3066\u3001\u8a8d\u77e5\u6a5f\u80fd\u306e\u5909\u5316\u304c\u8a8d\u3081\u3089\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u524d\u982d\u5074\u982d\u8449\u306e\u6a5f\u80fd\u969c\u5bb3\u306f\u3001\u8efd\u5ea6\u306e\u7570\u5e38\u304b\u3089\u91cd\u7be4\u306a\u524d\u982d\u5074\u982d\u8449\u8a8d\u77e5\u75c7\uff08FTD\uff09\u306e\u7bc4\u56f2\u3067\u767a\u73fe\u3057\u307e\u3059\u3002ALS\u3068FTD\u306e\u4e21\u65b9\u3092\u767a\u73fe\u3057\u305f\u60a3\u8005\u306f\u3001\u3044\u305a\u308c\u304b\u3092\u5358\u72ec\u3067\u767a\u73fe\u3057\u305f\u60a3\u8005\u306b\u6bd4\u3079\u3066\u751f\u5b58\u7387\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u00a0<sup>*44\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-171.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3281 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-171.jpg\" alt=\"ALS\u306b\u4fb5\u3055\u308c\u308b\u8eab\u4f53\u90e8\u4f4d\" width=\"409\" height=\"262\" \/><\/a><\/p>\n<h4>\u4e00\u822c\u7684\u539f\u56e0<\/h4>\n<p>ALS\u75c7\u4f8b\u306e\u3046\u3061\u3001\u7d0410\uff05\u304c\u5bb6\u65cf\u6027ALS\u3067\u3042\u308a\u3001\u5168\u90e8\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u5927\u90e8\u5206\u306e\u5bb6\u65cf\u6027ALS\u306f\u5358\u4e00\u907a\u4f1d\u5b50\u5909\u7570\u306e\u7d99\u627f\u306b\u3088\u3063\u3066\u767a\u75c7\u3057\u307e\u3059\u00a0<sup>*37<\/sup> \u3002\u907a\u4f1d\u7684\u539f\u56e0\u306b\u3064\u3044\u3066\u306f\u3001\u73fe\u5728\u3067\u306f\u7d043\u5206\u306e2\u306e\u5bb6\u65cf\u6027ALS\u75c7\u4f8b\u306810\uff05\u306e\u5b64\u767a\u6027ALS\u306b\u3064\u3044\u3066\u660e\u3089\u304b\u306b\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*36<\/sup> \u300260\uff05\u306eALS\u306e\u75c7\u4f8b\u306f\u3001SOD1\u3001TARDBP\/TDP-43\u3001FUS\u3001\u304a\u3088\u3073C9orf72\u306e\u308f\u305a\u304b4\u7a2e\u985e\u306e\u907a\u4f1d\u5b50\u306e\u5909\u7570\u306b\u3088\u3063\u3066\u767a\u75c7\u3057\u3066\u3044\u307e\u3059\u00a0<sup>*36<\/sup> \u3002\u7570\u306a\u308bALS\u5909\u7570\u304c\u540c\u3058\u7d30\u80de\u30d7\u30ed\u30bb\u30b9\u306b\u5f71\u97ff\u3057\u3066\u3044\u308b\u306e\u3067\u306f\u3068\u3044\u3046\u65b0\u3057\u3044\u30c6\u30fc\u30de\u304c\u63d0\u8d77\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001SQSTM1\u304a\u3088\u3073TBK1\u907a\u4f1d\u5b50\u306f\u3068\u3082\u306b\u30aa\u30fc\u30c8\u30d5\u30a1\u30b8\u30fc\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3057\u3066\u3044\u308b\u306e\u306b\u5bfe\u3057\u3001FUS\/TLS\uff08fused in sarcoma\uff09\u304a\u3088\u3073TARDBP\/TDP-43\u306f\u3068\u3082\u306bRNA\u4ee3\u8b1d\u306b\u304a\u3044\u3066\u6a5f\u80fd\u3057\u307e\u3059\uff08\u88684.7\uff09\u00a0<sup>*36,45<\/sup> \u3002Als2\/Alsin\u907a\u4f1d\u5b50\u306f\u82e5\u5e74\u767a\u75c7\u3001\u5e38\u67d3\u8272\u4f53\u52a3\u6027\u578b\u306e\u5bb6\u65cf\u6027ALS\u306b\u95a2\u4e0e\u3057\u307e\u3059\uff08\u5e73\u5747\u5e74\u9f626.5\uff09<sup>*36,41,45<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-172.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3282 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-172.jpg\" alt=\"\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7\u306b\u95a2\u4e0e\u3059\u308b\u9078\u629e\u30bf\u30f3\u30d1\u30af\u8cea\" width=\"806\" height=\"364\" \/><\/a><\/p>\n<h4>\u75c5\u614b\u751f\u7406\u5b66<\/h4>\n<p>ALS\u306e\u75c5\u614b\u306f\u3001\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u30b0\u30ea\u30aa\u30fc\u30b7\u30b9\uff08\u30cb\u30e5\u30fc\u30ed\u30f3\u6b7b\u306b\u53cd\u5fdc\u3057\u305f\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u5897\u52a0\uff09\u3092\u4f34\u3046\u904b\u52d5\u30cb\u30e5\u30fc\u30ed\u30f3\u306e\u5909\u6027\u304a\u3088\u3073\u6b7b\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0<sup>*48<\/sup>\u00a0\u3002\u30e6\u30d3\u30ad\u30c1\u30f3\u967d\u6027\u3001TARDBP\u967d\u6027\u306e\u30cb\u30e5\u30fc\u30ed\u30f3\u7d30\u80de\u8cea\u5185\u5c01\u5165\u4f53\uff08\u4e0d\u6eb6\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u51dd\u96c6\u4f53\uff09\u306f\u3001\u5b9f\u8cea\u7684\u306b\u3001SOD1\u307e\u305f\u306fFUS\u5909\u7570\u306b\u3088\u308bALS\u3092\u9664\u304f\u5168\u3066\u306eALS\u5f62\u614b\u306e\u9855\u8457\u306a\u7279\u5fb4\u3067\u3059\u00a0<sup>*36, 38,49-51<\/sup> \u3002\u3053\u306e\u305f\u3081\u3001\u75be\u60a3\u7279\u6709\u306e\u75c5\u614b\u751f\u7406\u5b66\u304a\u3088\u3073\/\u307e\u305f\u306f\u75be\u60a3\u7279\u6709\u306e\u907a\u4f1d\u5b50\u95a2\u9023\u6027\u306b\u57fa\u3065\u3044\u3066\u3001ALS\u306e\u69d8\u3005\u306a\u4e9c\u578b\u3092\u5b9a\u7fa9\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30cb\u30e5\u30fc\u30ed\u30f3\u7d30\u80de\u8cea\u5185\u5c01\u5165\u4f53\u306f\u3001\u305d\u308c\u81ea\u4f53\u304c\u7d30\u80de\u6b7b\u306b\u5bc4\u4e0e\u3057\u3066\u3044\u308b\u304b\u306f\u672a\u77e5\u3067\u3059\u304c\u3001ALS\u306e\u8a3a\u65ad\u30de\u30fc\u30ab\u30fc\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*49,52<\/sup> \u3002ALS\u306b\u95a2\u9023\u3059\u308b\u7279\u6027\u306e\u6982\u8981\u3092\u88684.8\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-173.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3283 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-173.jpg\" alt=\"\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7\u306e\u75c5\u614b\u751f\u7406\u5b66\" width=\"813\" height=\"724\" \/><\/a><\/p>\n<h4>\u30bf\u30fc\u30b2\u30c3\u30c8\u304a\u3088\u3073\u6709\u671b\u306a\u6cbb\u7642\u85ac<\/h4>\n<p>\u65e2\u5b58\u306eALS\u306b\u5bfe\u3059\u308b\u85ac\u7269\u7642\u6cd5\u306f\u3001\u4e3b\u306b\u5bfe\u75c7\u7684\u3067\u3001\u75be\u60a3\u9032\u884c\u3092\u9045\u5ef6\u307e\u305f\u306f\u56de\u5fa9\u3055\u305b\u308b\u3088\u308a\u3082\u3001\u75d9\u6523\u3001\u75d9\u7e2e\u3001\u553e\u6db2\u5206\u6ccc\u904e\u591a\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u75c7\u72b6\u306e\u5f71\u97ff\u3092\u8efd\u6e1b\u3055\u305b\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u3002\u4eba\u5de5\u547c\u5438\u5668\u3082\u547c\u5438\u3092\u88dc\u52a9\u3059\u308b\u76ee\u7684\u3067\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002 \u30cb\u30e5\u30fc\u30ed\u30f3\u6b7b\u304b\u3089\u306e\u4fdd\u8b77\u3084\u75be\u60a3\u9032\u884c\u306e\u7de9\u548c\u3092\u53ef\u80fd\u3068\u3059\u308b\u85ac\u5264\u3092\u767a\u898b\u3059\u308b\u305f\u3081\u306e\u52aa\u529b\u304c\u7d9a\u3051\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3044\u307e\u3060\u6210\u529f\u306b\u3044\u305f\u3063\u3066\u3044\u307e\u305b\u3093\u3002FDA\u627f\u8a8d\u85ac\u306e1\u3064\u3067\u3042\u308b\u30ea\u30eb\u30be\u30fc\u30eb\u306f\u3001\u308f\u305a\u304b\u306a\u751f\u5b58\u671f\u9593\u5ef6\u9577\u52b9\u679c\uff08\u751f\u5b58\u671f\u9593\u4e2d\u592e\u5024\u304c\u7d043\u30f6\u6708\u5ef6\u9577\uff09\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u3053\u308c\u306fN-\u30e1\u30c1\u30eb-D-\u30a2\u30b9\u30d1\u30e9\u30ae\u30f3\u9178\uff08NMDA\uff09\u53d7\u5bb9\u4f53\u6d3b\u6027\u3068\u96fb\u4f4d\u4f9d\u5b58\u6027\u30ca\u30c8\u30ea\u30a6\u30e0\u30c1\u30e3\u30cd\u30eb\u6d3b\u6027\u306e\u6291\u5236\u304a\u3088\u3073\/\u307e\u305f\u306f\u30b0\u30eb\u30bf\u30df\u30f3\u9178\u8208\u596e\u6bd2\u6027\u3092\u6e1b\u5c11\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3082\u305f\u3089\u3055\u308c\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u00a0<sup>*53\u00a0<\/sup>\u3002<\/p>\n<p>ALS\u4e9c\u578b\u306b\u7279\u6709\u306e\u7279\u5fb4\u3092\u5229\u7528\u3059\u308b\u65b0\u3057\u3044\u6226\u7565\u304c\u3042\u308b\u4e00\u65b9\u3001\u4e00\u822c\u7684\u306a\u7d30\u80de\u30d7\u30ed\u30bb\u30b9\u3084\u795e\u7d4c\u5909\u6027\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b\u3082\u306e\u3082\u3042\u308a\u307e\u3059\uff08\u88684.9\uff09\u00a0<sup>*54-62<\/sup> \u3002\u524d\u8005\u306e\u4f8b\u3068\u3057\u3066\u3001\u5bb6\u65cf\u6027SOD1\u306e\u75c5\u614b\u306f\u7279\u6709\u3067\u512a\u6027\u306aSOD1\u542b\u6709\u5c01\u5165\u4f53\u306e\u6bd2\u6027\u4f5c\u7528\u3092\u793a\u3059\u305f\u3081\u3001\u5909\u7570\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30ec\u30d9\u30eb\u3092\u6e1b\u5c11\u3055\u305b\u308b\u30a2\u30f3\u30c1\u30bb\u30f3\u30b9\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u6226\u7565\u306f\u6709\u76ca\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u5e79\u7d30\u80de\u7642\u6cd5\u306f\u3001\u904b\u52d5\u30cb\u30e5\u30fc\u30ed\u30f3\u56de\u8def\u306e\u4fee\u5fa9\u3042\u308b\u3044\u306f\u795e\u7d4c\u6804\u990a\u56e0\u5b50\u306e\u4f9b\u7d66\u3001\u3055\u3089\u306b\u306fALS\/FTD\u95a2\u9023\u5909\u7570\u3092\u6709\u3059\u308bALS\u304a\u3088\u3073\u524d\u982d\u5074\u982d\u8449\u8a8d\u77e5\u75c7\uff08FTD\uff09\u306e\u30d2\u30c8\u30cb\u30e5\u30fc\u30ed\u30f3\u3092\u7528\u3044\u308bin vitro\u30e2\u30c7\u30eb\u306e\u958b\u767a\u306b\u6709\u671b\u306a\u65b0\u3057\u3044\u65b9\u6cd5\u3067\u3059\u3002\u6cbb\u7642\u306b\u304a\u3044\u3066\u3001\u3053\u308c\u3089\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3001\u795e\u7d4c\u5e79\u7d30\u80de\u3001\u9020\u8840\u7d30\u80de\u3001\u307e\u305f\u306f\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\u7531\u6765\u795e\u7d4c\u524d\u99c6\u7d30\u80de\u306eCNS\u3078\u306e\u79fb\u690d\u304c\u60f3\u5b9a\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3284 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-174.jpg\" alt=\"\u7b4b\u59d4\u7e2e\u6027\u5074\u7d22\u786c\u5316\u75c7\u307e\u305f\u306f\u524d\u982d\u5074\u982d\u8449\u8a8d\u77e5\u75c7\u306b\u5bfe\u3059\u308b\u958b\u767a\u4e2d\u306e\u6cbb\u7642\u6cd5\" width=\"806\" height=\"481\" \/><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u76ee\u7684\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u7279\u7570\u7684\u306a\u6297\u4f53\u304a\u3088\u3073\u514d\u75ab\u30a2\u30c3\u30bb\u30a4\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h2>\u591a\u767a\u6027\u786c\u5316\u75c7<\/h2>\n<h4>\u591a\u767a\u6027\u786c\u5316\u75c7\u306e\u7279\u5fb4<\/h4>\n<p>\u591a\u767a\u6027\u786c\u5316\u75c7\uff08MS\uff09\u306f\u3001\u8133\u304a\u3088\u3073\u810a\u9ac4\u306b\u304a\u3051\u308b\u6162\u6027\u9032\u884c\u578b\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u3067\u3001\u708e\u75c7\u3001\u8131\u9ac4\u3001\u304a\u3088\u3073\u8ef8\u7d22\u55aa\u5931\u3092\u7279\u5fb4\u3068\u3057\u307e\u3059\u00a0<sup>*63-65<\/sup> \u3002MS\u306b\u306f\u591a\u304f\u306e\u5f62\u614b\u304c\u3042\u308a\u3001\u7d0490\uff05\u306e\u60a3\u8005\u306f\u5c11\u306a\u304f\u3068\u3082\u3042\u308b\u7a0b\u5ea6\u306e\u56de\u5fa9\u304a\u3088\u3073\u81e8\u5e8a\u7684\u5bdb\u89e3\u3068\u518d\u767a\u3092\u7e70\u308a\u8fd4\u3057\u307e\u3059\u3002\u4e8c\u56de\u76ee\u306e\u7d99\u7d9a\u7684\u306a\u75be\u60a3\u9032\u884c\u304a\u3088\u3073\u5897\u60aa\u671f\u306b\u5165\u3063\u305f\u60a3\u8005\u306e50\uff05\u4ee5\u4e0a\u306b\u304a\u3044\u3066\u3001\u901a\u5e38\u3001\u7d4c\u6642\u7684\u306b\u80fd\u529b\u969c\u5bb3\u304c\u751f\u3058\u307e\u3059\u00a0<sup>*63,66,67<\/sup> \u3002\u518d\u767a\u306f\u3001\u75c5\u5de3\u306e\u89e3\u5256\u5b66\u7684\u90e8\u4f4d\u3001\u767a\u4f5c\u306e\u767a\u75c7\u3001\u6301\u7d9a\u6642\u9593\u3001\u304a\u3088\u3073\u983b\u5ea6\u3001\u306a\u3089\u3073\u306b\u5bdb\u89e3\u306e\u8cea\u306b\u3088\u3063\u3066\u8457\u3057\u304f\u7570\u306a\u308a\u307e\u3059\u00a0<sup>*66<\/sup> \u3002MS\u767a\u4f5c\u306e\u4e00\u822c\u7684\u306a\u81e8\u5e8a\u75c7\u72b6\u306f\u3001\u56db\u80a2\u306e\u9ebb\u75fa\u307e\u305f\u306f\u523a\u75db\u3001\u7b4b\u529b\u4f4e\u4e0b\u3001\u5e73\u8861\u969c\u5bb3\u3001\u8996\u899a\u969c\u5bb3\u3001\u304a\u3088\u3073\u8180\u80f1\/\u8178\u306e\u6a5f\u80fd\u969c\u5bb3\u3001\u306a\u3089\u3073\u306b\u305d\u306e\u4ed6\u306e\u75c7\u72b6\u3067\u3059\uff08\u56f34.7\uff09\u00a0<sup>*63<\/sup> \u3002MS\u306b\u5bfe\u3059\u308b\u6cbb\u7642\u85ac\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u304c\u3001\u73fe\u5728\u627f\u8a8d\u3055\u308c\u3066\u3044\u308b\u7642\u6cd5\u306b\u3088\u3063\u3066\u75c7\u72b6\u3092\u8efd\u6e1b\u3057\u3001\u75be\u60a3\u9032\u884c\u3092\u9045\u5ef6\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-175.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3285 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-175.jpg\" alt=\"\u591a\u767a\u6027\u786c\u5316\u75c7\u306e\u75c5\u5de3\u5f62\u6210\u306e\u53ef\u80fd\u6027\u306e\u3042\u308b\u8907\u6570\u306e\u5668\u5b98\u7cfb\" width=\"408\" height=\"378\" \/><\/a><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-176.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3286 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-176.jpg\" alt=\"HLA-DRB1 Rabbit Polyclonal Antibody\u3000\" width=\"403\" height=\"206\" \/><\/a><\/p>\n<h4>\u4e00\u822c\u7684\u306a\u539f\u56e0\u304a\u3088\u3073\u30ea\u30b9\u30af\u30d5\u30a1\u30af\u30bf\u30fc<\/h4>\n<p>\u7d0420\uff05\u306eMS\u60a3\u8005\u306b\u306f\u3001MS\u306e\u5bb6\u65cf\u6b74\u304c\u3042\u308a\u3001MS\u767a\u75c7\u306b\u95a2\u9023\u3059\u308b\u907a\u4f1d\u8981\u56e0\u304c\u898b\u3089\u308c\u307e\u3059\u00a0<sup>*68<\/sup> \u3002\u4f8b\u3048\u3070\u3001\u540c\u6027\u306e\u4e8c\u5375\u6027\u53cc\u751f\u5150\u306b\u304a\u3051\u308bMS\u306e\u4e00\u81f4\u7387\u306f5\uff05\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u4e00\u5375\u6027\u53cc\u751f\u5150\u306b\u304a\u3051\u308bMS\u306e\u4e00\u81f4\u7387\u306f\u7d0420\uff5e40\uff05\u3067\u3059\u00a0<sup>*67,69-71<\/sup> \u3002\u4e3b\u8981\u7d44\u7e54\u9069\u5408\u6027\u8907\u5408\u4f53\uff08MHC\uff09\u30af\u30e9\u30b9II\u907a\u4f1d\u5b50HLA-DRB1\u306f\u3001MS\u767a\u75c7\u3068\u5f37\u3044\u95a2\u9023\u3092\u6301\u3064\u8840\u6e05\u5b66\u7684\u30de\u30fc\u30ab\u30fcHLA-DR2\u304a\u3088\u3073HLADQ6\u306b\u5bfe\u5fdc\u3059\u308b\u30cf\u30d7\u30ed\u30bf\u30a4\u30d7\u306e\u4e00\u90e8\u3067\u3059\u00a0<sup>*68,69<\/sup> \u3002\u3053\u308c\u3089\u306eHLA\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u3001T\u7d30\u80de\u3078\u306e\u6297\u539f\u63d0\u793a\u306b\u95a2\u4e0e\u3059\u308b\u7d30\u80de\u8868\u9762\u6297\u539f\u3068\u3057\u3066\u50cd\u304fHLA\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3059\u00a0<sup>*68<\/sup> \u3002\u6570\u591a\u304f\u306e\u74b0\u5883\u8981\u56e0\u304c\u3055\u3089\u306bMS\u767a\u75c7\u306e\u975e\u907a\u4f1d\u7684\u30ea\u30b9\u30af\u3068\u3057\u3066\u95a2\u4e0e\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u63d0\u8a00\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5730\u7406\u7684\u6761\u4ef6\u3068MS\u6709\u75c5\u7387\u306f\u95a2\u4fc2\u3057\u3066\u304a\u308a\u3001\u65e5\u5149\u3078\u306e\u66dd\u9732\u91cf\u306e\u4f4e\u4e0b\u306b\u4f34\u3046\u30d3\u30bf\u30df\u30f3D\u7523\u751f\u91cf\u306e\u4f4e\u4e0b\u3068\u3001\u8d64\u9053\u304b\u3089\u306e\u8ddd\u96e2\u304c\u96e2\u308c\u3066\u3044\u308b\u5730\u57df\u3067\u306e\u6709\u75c5\u7387\u306e\u5897\u52a0\u306b\u4e00\u81f4\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u4ed6\u306eMS\u767a\u75c5\u30ea\u30b9\u30af\u3092\u5897\u52a0\u3055\u305b\u308b\u3068\u8003\u3048\u3089\u308c\u308b\u74b0\u5883\u8981\u56e0\u3068\u3057\u3066\u306f\u3001\u55ab\u7159\u3084\u611f\u67d3\u75c7\u7f79\u60a3\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u00a0<sup>*72\u00a0<\/sup>\u3002<\/p>\n<h4>\u75c5\u614b\u751f\u7406\u5b66<\/h4>\n<p>MS\u306f\u3001\u8ef8\u7d22\u640d\u50b7\u304a\u3088\u3073\u8131\u9ac4\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001MS\u306e\u767a\u75c5\u304a\u3088\u3073\u9032\u884c\u306b\u5bc4\u4e0e\u3059\u308bCNS\u4fee\u5fa9\u6a5f\u69cb\u306e\u969c\u5bb3\u3068\u514d\u75ab\u8abf\u7bc0\u4e0d\u5168\u3092\u7279\u5fb4\u3068\u3059\u308b\u8907\u5408\u75be\u60a3\u3067\u3059\uff08\u56f34.8\uff09*<sup>64,65<\/sup> \u3002MS\u306e\u9855\u8457\u306a\u7279\u5fb4\u306f\u3001\u767d\u8cea\u304a\u3088\u3073\u7070\u767d\u8cea\u5168\u4f53\u306b\u308f\u305f\u308bCNS\u306e\u8131\u9ac4\u640d\u50b7\u3084\u69d8\u3005\u306a\u30b5\u30a4\u30ba\u3067\u4e0d\u898f\u5247\u306b\u6563\u5728\u3059\u308b\u30d7\u30e9\u30fc\u30af\u3067\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u8133\u5ba4\u3001\u8996\u899a\u7cfb\u3001\u8133\u5e79\u3001\u304a\u3088\u3073\u810a\u9ac4\u306e\u8fd1\u304f\u3067\u6700\u3082\u3088\u304f\u898b\u3089\u308c\u307e\u3059 *<sup>73<\/sup> \u3002\u30df\u30a8\u30ea\u30f3\u5869\u57fa\u6027\u30bf\u30f3\u30d1\u30af\u8cea\uff08MBP\uff09\u306b\u306f\u3001CNS\u3092\u69cb\u6210\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u6210\u5206\u306e\u7d0430\uff05\u304c\u542b\u307e\u308c\u307e\u3059\u3002MBP\uff08\u307e\u305f\u306fCNS\u95a2\u9023\u30da\u30d7\u30c1\u30c9\uff09\u3092\u30a2\u30b8\u30e5\u30d0\u30f3\u30c8\u3068\u3068\u3082\u306b\u76ae\u4e0b\u6295\u4e0e\u3059\u308b\u3053\u3068\u3067\u3001\u5b9f\u9a13\u7684\u30a2\u30ec\u30eb\u30ae\u30fc\u6027\u8133\u810a\u9ac4\u708e\uff08EAE\uff09\u306e\u5341\u5206\u306b\u78ba\u7acb\u3055\u308c\u305fMS\u30de\u30a6\u30b9\u30e2\u30c7\u30eb\u304c\u8a98\u5c0e\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001MBP\u306fMS\u60a3\u8005\u306e\u6025\u6027\u8131\u9ac4\u767a\u75c7\u306e\u8133\u810a\u9ac4\u6db2\u306b\u304a\u3051\u308b\u691c\u51fa\u3092\u53ef\u80fd\u3068\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3067\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-177.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3287 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-177.jpg\" alt=\"\u8131\u9ac4\u306e\u6a5f\u80fd\u7684\u7d50\u679c\" width=\"411\" height=\"342\" \/><\/a><\/p>\n<h4>\u514d\u75ab\u75c5\u7406\u5b66<\/h4>\n<p>MS\u306b\u304a\u3051\u308b\u514d\u75ab\u5fdc\u7b54\u306e\u8abf\u7bc0\u4e0d\u5168\u306f\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\uff08M\u03a6\uff09\u3001\u6a39\u72b6\u7d30\u80de\uff08DC\uff09\u306a\u3069\u306e\u6297\u539f\u63d0\u793a\u7d30\u80de\uff08APC\uff09\u306b\u3088\u308b\u5916\u6765\u6297\u539f\u304a\u3088\u3073\u81ea\u5df1\u6297\u539f\u306e\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u304a\u3088\u3073\u63d0\u793a\u306b\u95a2\u308f\u308a\u307e\u3059\u3002APC\u8868\u9762\u306eMHC\u5206\u5b50\u306b\u7d50\u5408\u3057\u305f\u540c\u7a2e\u6297\u539f\u3092\u8a8d\u8b58\u3057\u3001\u7d9a\u3044\u3066\u6d3b\u6027\u5316\u672b\u68a2\u6027T\u7d30\u80de\u304c\u8840\u6db2\u8133\u95a2\u9580\uff08BBB\uff09\u3092\u901a\u904e\u3057\u307e\u3059\u3002\u6d3b\u6027\u5316B\u7d30\u80de\u3082BBB\u3092\u901a\u904e\u3057\u307e\u3059\u3002CNS\u306b\u304a\u3044\u3066\u3001T\u7d30\u80de\u306f\u3001CNS\u95a2\u9023\u6297\u539f\u3092\u63d0\u793a\u3059\u308b\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u3084\u30a2\u30b9\u30c8\u30ed\u30b5\u30a4\u30c8\u306b\u3088\u308a\u518d\u6d3b\u6027\u5316\u3055\u308c\u308b\u3068\u3001\u708e\u75c7\u8a98\u767a\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u5206\u6ccc\u3057\u307e\u3059\u3002\u708e\u75c7\u8a98\u767a\u6027\u306eCNS\u5fae\u5c0f\u74b0\u5883\u306b\u304a\u3051\u308b\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u306f\u3001\u816b\u760d\u58ca\u6b7b\u56e0\u5b50\u03b1\uff08TNF-\u03b1\uff09\u3092\u767a\u73fe\u3057\u3001\u7834\u58ca\u7684\u306a\u30b9\u30fc\u30d1\u30fc\u30aa\u30ad\u30b7\u30c9\u304a\u3088\u3073\u4e00\u9178\u5316\u7a92\u7d20\u7a2e\u3092\u653e\u51fa\u3057\u307e\u3059\uff08\u56f34.9\uff09\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-179.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3289 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-179.jpg\" alt=\"\u591a\u767a\u6027\u786c\u5316\u75c7\u306e\u75c5\u614b\u751f\u7406\u5b66\" width=\"806\" height=\"323\" \/><\/a><\/p>\n<p>B\u7d30\u80de\u3082\u307e\u305f\u6297\u539f\u3092T\u7d30\u80de\u306b\u63d0\u793a\u3057\u3001\u708e\u75c7\u6027\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u3092\u5206\u6ccc\u3057\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u7d30\u80de\u3092\u6d3b\u6027\u5316\u3059\u308b\u8131\u9ac4\u6297\u4f53\u3092\u7523\u751f\u3057\u307e\u3059\u3002\u8131\u9ac4\u6297\u4f53\u306b\u3088\u3063\u3066\u99c6\u52d5\u3055\u308c\u308b\u88dc\u4f53\u30ab\u30b9\u30b1\u30fc\u30c9\u306e\u8a98\u5c0e\u306b\u3088\u308a\u3001\u819c\u4fb5\u8972\u8907\u5408\u4f53\uff08MAC\uff09\u304c\u69cb\u7bc9\u3055\u308c\u3001\u7d30\u80de\u819c\u306b\u5b54\u304c\u5f62\u6210\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30df\u30a8\u30ea\u30f3\u819c\u304c\u7834\u58ca\u3055\u308c\u307e\u3059\u3002\u8907\u6570\u306e\u8981\u56e0\u304cT\u7d30\u80de\u3001\u30de\u30af\u30ed\u30d5\u30a1\u30fc\u30b8\u3001B\u7d30\u80de\u3001\u304a\u3088\u3073\u30df\u30af\u30ed\u30b0\u30ea\u30a2\u306e\u7570\u5e38\u306a\u6d3b\u6027\u3092\u4ecb\u3059\u308b\u8131\u9ac4\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002MS\u306b\u304a\u3044\u3066\u3001\u30df\u30a8\u30ea\u30f3\u5f62\u6210\u30aa\u30ea\u30b4\u30c7\u30f3\u30c9\u30ed\u30b5\u30a4\u30c8\uff08OLG\uff09\u306e\u514d\u75ab\u4ecb\u5728\u6027\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u304a\u3088\u3073\u58ca\u6b7b\u306f\u3001MS\u30d7\u30e9\u30fc\u30af\u306b\u304a\u3051\u308b\u7d30\u80de\u55aa\u5931\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u00a0<sup>*74,75<\/sup> \u3002\u8ef8\u7d22\u640d\u50b7\u306f\u3001MS\u60a3\u8005\u306b\u304a\u3051\u308b\u81e8\u5e8a\u7684\u969c\u5bb3\u306e\u4e3b\u306a\u539f\u56e0\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u8ef8\u7d22\u8f38\u9001\u969c\u5bb3\u306f\u3001\u591a\u304f\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u5171\u901a\u3059\u308b\u7279\u5fb4\u3067\u3059\u3002\u30a2\u30df\u30ed\u30a4\u30c9\u524d\u99c6\u4f53\u30bf\u30f3\u30d1\u30af\u8cea\uff08APP\uff09\u306b\u5bfe\u3057\u7279\u7570\u7684\u306aMS\u6297\u4f53\u304a\u3088\u3073\u975e\u30ea\u30f3\u9178\u5316\u30cb\u30e5\u30fc\u30ed\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u91cd\u9396\uff08NFH\uff09\u306f\u3001\u8ef8\u7d22\u640d\u50b7\u306e\u6709\u7528\u306a\u30de\u30fc\u30ab\u30fc\u306b\u306a\u308a\u5f97\u307e\u3059\u00a0<sup>*76\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-178.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3288 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-178.jpg\" alt=\"MBP Mouse Monoclonal Antibody (2H9)\" width=\"398\" height=\"174\" \/><\/a><\/p>\n<h4>MS\u306b\u304a\u3051\u308bT\u7d30\u80de\u306e\u5f79\u5272<\/h4>\n<p>MS\u306b\u304a\u3044\u3066\u3001\u8ef8\u7d22\u640d\u50b7\u306f\u6570\u591a\u304f\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u3088\u3063\u3066\u8d77\u3053\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u81ea\u5df1\u53cd\u5fdc\u6027B\u7d30\u80de\u304a\u3088\u3073\u9aa8\u9ac4\u7531\u6765\u7d30\u80de\u304b\u3089\u306e\u640d\u50b7\u306b\u52a0\u3048\u3066\u3001\u8ef8\u7d22\u306fCD4+\u30b5\u30d6\u30bb\u30c3\u30c8\u7531\u6765\u306e\u7d30\u80de\u304a\u3088\u3073CD8+\u7d30\u80de\u50b7\u5bb3\u6027T\u7d30\u80de\u306b\u3088\u3063\u3066\u3082\u653b\u6483\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u00a0<sup>*77-80<\/sup> \u3002MS\u60a3\u8005\u3067\u306f\u5bfe\u7167\u7fa4\u306b\u6bd4\u3057\u3066\u3001\u3088\u308a\u9ad8\u983b\u5ea6\u306b\u30df\u30a8\u30ea\u30f3\u6297\u539f\u306b\u5bfe\u3059\u308bT\u7d30\u80de\u53cd\u5fdc\u6027\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u6570\u591a\u304f\u306e\u8a66\u9a13\u3067\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u30023\u7a2e\u985e\u306e\u5341\u5206\u306b\u7279\u6027\u6c7a\u5b9a\u3055\u308c\u305f\u30df\u30a8\u30ea\u30f3\u6297\u539f\u3068\u3057\u3066\u3001\u30df\u30a8\u30ea\u30f3\u5869\u57fa\u6027\u30bf\u30f3\u30d1\u30af\u8cea\uff08MBP\uff09\u3001\u30d7\u30ed\u30c6\u30aa\u30ea\u30d4\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\uff08PLP\uff09\u3001\u304a\u3088\u3073\u30df\u30a8\u30ea\u30f3\u30aa\u30ea\u30b4\u30c7\u30f3\u30c9\u30ed\u30b5\u30a4\u30c8\u7cd6\u30bf\u30f3\u30d1\u30af\u8cea\uff08MOG\uff09\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001T\u7d30\u80de\u6d3b\u6027\u5316\u306f\u30df\u30a8\u30ea\u30f3\u640d\u50b7\u3092\u751f\u3058\u308b\u30df\u30a8\u30ea\u30f3\u6297\u539f\u306e\u904a\u96e2\u306b\u7d9a\u767a\u3057\u3066\u8d77\u3053\u308b\u306e\u304b\u3001\u3042\u308b\u3044\u306fT\u7d30\u80de\u304c\u4e00\u6b21\u640d\u50b7\u306e\u539f\u56e0\u3067\u3042\u308b\u306e\u304b\u3001\u4e21\u65b9\u304b\u306b\u3064\u3044\u3066\u306f\u660e\u3089\u304b\u306b\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u00a0<sup>*81,82\u00a0<\/sup>\u3002<\/p>\n<p>\u6d3b\u6027\u5316\u30ea\u30f3\u30d1\u7403\u306b\u3088\u308a\u5206\u6ccc\u3055\u308c\u305f\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306f\u3001\u7d44\u7e54\u640d\u50b7\u3092\u4fc3\u9032\u307e\u305f\u306f\u4fee\u5fa9\u3092\u963b\u5bb3\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30b0\u30ea\u30a2\u7d30\u80de\u304a\u3088\u3073\u30cb\u30e5\u30fc\u30ed\u30f3\u3092\u76f4\u63a5\u653b\u6483\u3057\u307e\u3059\u3002\u7d30\u80de\u30b9\u30c8\u30ec\u30b9\u304a\u3088\u3073\u5909\u6027\u306e\u4e0b\u6d41\u7d4c\u8def\u306f\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306b\u3088\u308b\u7d30\u80de\u6b7b\u53d7\u5bb9\u4f53\u306e\u95a2\u4e0e\u3001\u6d3b\u6027\u9178\u7d20\u7a2e\u306e\u751f\u6210\u3001\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u6a5f\u80fd\u4e0d\u5168\u3001\u3042\u308b\u3044\u306f\u30b0\u30eb\u30bf\u30df\u30f3\u9178\u307e\u305f\u306f\u30ab\u30eb\u30b7\u30a6\u30e0\u306b\u5bfe\u3059\u308b\u8208\u596e\u6bd2\u6027\u306b\u3088\u3063\u3066\u5a92\u4ecb\u3055\u308c\u307e\u3059\u00a0<sup>*83-85\u00a0<\/sup>\u3002<\/p>\n<p>\u6b74\u53f2\u7684\u306b\u3001Th1\u7d30\u80de\u306fMS\u306b\u304a\u3051\u308b\u708e\u75c7\u306e\u4e3b\u8981\u306a\u30e1\u30c7\u30a3\u30a8\u30fc\u30bf\u30fc\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u73fe\u5728\u3067\u306f\u3001IL-17\u304a\u3088\u3073IL-22\u3092\u5206\u6ccc\u3059\u308bCD4+ Th17\u7d30\u80de\u304cMS\u306e\u6cbb\u7642\u306b\u6975\u3081\u3066\u91cd\u8981\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u3067\u3042\u308b\u3053\u3068\u304c\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u56f34.10\uff09\u00a0<sup>*82<\/sup> \u3002MS\u75c5\u614b\u5f62\u6210\u306b\u95a2\u4e0e\u3059\u308b\u69d8\u3005\u306a\u53d7\u5bb9\u4f53\u304a\u3088\u3073\u53ef\u6eb6\u6027\u56e0\u5b50\u306e\u6982\u7565\u3092\u56f34.10\u306b\u793a\u3057\u307e\u3059\u3002\u305d\u306e\u591a\u304f\u306fMS\u6cbb\u7642\u306e\u305f\u3081\u306e\u85ac\u5264\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u00a0<sup>*80,82,86-95\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-180.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3290 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-180.jpg\" alt=\"\u30ca\u30a4\u30fc\u30d6CD4+T\u7d30\u80de\" width=\"406\" height=\"374\" \/><\/a><\/p>\n<h4>\u65e2\u5b58\u306e\u6cbb\u7642\u6cd5\u304a\u3088\u3073\u6709\u671b\u306a\u30bf\u30fc\u30b2\u30c3\u30c8<\/h4>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-181.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3291 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-181.jpg\" alt=\"\u591a\u767a\u6027\u786c\u5316\u75c7\u306b\u5bfe\u3059\u308b\u6709\u671b\u306a\u6cbb\u7642\u85ac\" width=\"812\" height=\"780\" \/><\/a><\/p>\n<p>AD\u3001PD\u3001\u304a\u3088\u3073ALS\u306a\u3069\u306e\u4ed6\u306e\u795e\u7d4c\u5909\u6027\u75be\u60a3\u3068\u6bd4\u8f03\u3057\u3066\u3001MS\u306b\u5bfe\u3057\u3066\u306f\u6570\u591a\u304f\u306e\u75be\u60a3\u4fee\u98fe\u7642\u6cd5\u304c\u958b\u767a\u304a\u3088\u3073\u627f\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u00a0<sup>*96\u00a0<\/sup>\u3002<br \/>\n\u3053\u308c\u3089\u306e\u85ac\u5264\u306b\u306f\u3001\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u3001\u30b0\u30e9\u30c1\u30e9\u30de\u30fc\u9162\u9178\u5869\u3001\u751f\u7269\u88fd\u5264\u3001\u304a\u3088\u3073\u7d4c\u53e3\u5264\u304c\u542b\u307e\u308c\u307e\u3059\uff08\u88684.11\uff09\u00a0<sup>*93,96-107\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-182.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3292 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/1-182.jpg\" alt=\"\u30df\u30a8\u30ea\u30f3\" width=\"402\" height=\"205\" \/><\/a> <img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3293 aligncenter\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/2-48.jpg\" alt=\"\u591a\u767a\u6027\u786c\u5316\u75c7\u306e\u65e2\u5b58\u306e\u6cbb\u7642\u6cd5\" width=\"813\" height=\"500\" \/>\u65e2\u5b58\u306e\u6cbb\u7642\u6cd5\u306b\u52a0\u3048\u3066\u3001\u8907\u6570\u306e\u75be\u60a3\u4fee\u98fe\u6cbb\u7642\u85ac\u304cMS\u306b\u5bfe\u3059\u308b\u6709\u671b\u306a\u6cbb\u7642\u6cd5\u3068\u3057\u3066\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u69d8\u3005\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u958b\u767a\u521d\u671f\u6bb5\u968e\u3084\u5f8c\u671f\u6bb5\u968e\u306b\u3042\u308a\u307e\u3059\u3002\u514d\u75ab\u8abf\u7bc0\u6226\u7565\u306b\u306f\u3001\u81ea\u5df1T\u7d30\u80de\u7642\u6cd5\u3001B\u7d30\u80de\u304a\u3088\u3073T\u7d30\u80de\u3092\u4ecb\u3059\u308b\u514d\u75ab\u4fc3\u9032\u53cd\u5fdc\u3092\u6291\u5236\u3059\u308b\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3001T\u7d30\u80de\u53d7\u5bb9\u4f53\u30da\u30d7\u30c1\u30c9\u30ef\u30af\u30c1\u30f3\u3001\u304a\u3088\u3073\u4ed6\u306e\u65b0\u3057\u3044\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u3088\u3046\u3084\u304f\u3001\u9593\u8449\u7cfb\u5e79\u7d30\u80de\u304a\u3088\u3073\u4eba\u5de5\u591a\u80fd\u6027\u5e79\u7d30\u80de\u306e\u795e\u7d4c\u4fdd\u8b77\u304a\u3088\u3073\/\u307e\u305f\u306f\u795e\u7d4c\u5909\u6027\u7279\u6027\u306b\u95a2\u3059\u308b\u8a55\u4fa1\u3092\u884c\u3046\u81e8\u5e8a\u8a66\u9a13\u304c\u9032\u884c\u4e2d\u3067\u3059\u00a0<sup>*108-111\u00a0<\/sup>\u3002<\/p>\n<p><a href=\"http:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/immunoassays.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f53\u793e\u3067\u306f\u3001MS\u767a\u75c5\u306b\u95a2\u308f\u308b\u7814\u7a76\u30d7\u30ed\u30bb\u30b9\u3067\u4f7f\u7528\u3055\u308c\u308b\u4e00\u6b21\u6297\u4f53\u306b\u52a0\u3048\u3066\u3001\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u5b9a\u91cf\u7528\u306e\u9ad8\u54c1\u8cea\u306aELISA\u304a\u3088\u3073Luminex\u30a2\u30c3\u30bb\u30a4\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u8a73\u3057\u3044\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3053\u3061\u3089\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/a><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u5f53\u8a18\u4e8b\u306f\u3001\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5185\u5bb9\u3092\u542b\u3080PDF\u306f\u4e0b\u8a18\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u9802\u3051\u307e\u3059\u3002<\/p>\n<p>\uff5e\u4e3b\u306a\u5185\u5bb9\uff5e<\/p>\n<ol>\n<li>\u30a4\u30f3\u30c8\u30ed\u30c0\u30af\u30b7\u30e7\u30f3<\/li>\n<li>\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306b\u304a\u3051\u308b\u5171\u901a\u306e\u30c6\u30fc\u30de<\/li>\n<li>\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u3078\u306e\u53d6\u308a\u7d44\u307f<\/li>\n<li>\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3<\/li>\n<li>\u6297\u4f53\uff1a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u306e\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb<\/li>\n<\/ol>\n<p><strong><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/antibodies-learning-center\/antibodies-resource-library\/antibody-neurodegeneration-guidebook.html?CID=bid_pca_aup_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_ab5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7121\u6599\u30ac\u30a4\u30c9\u30d6\u30c3\u30af\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/strong><br \/>\n<span style=\"font-size: 8pt\">\u53c2\u8003\u6587\u732e\uff1a<br \/>\n1. Poewe W (2006) The natural history of Parkinson\u2019s disease. J Neurol 253 Suppl\u00a07:VII2\u2013VII6.<br \/>\n2. Farlow J, Pankratz ND, Wojcieszek J et al. (2004) Parkinson disease overview.\u00a0[Updated 2014]. In: Pagon RA, Adam MP, Ardinger HH et al., editors.\u00a0GeneReviews [Internet]. Seattle (WA): University of Washington, Seattle; 1993-2015. Available from: http:\/\/www.ncbi.nlm.nih.gov\/books\/NBK1223\/.<br \/>\n3. Kurtis MM, Martinez-Martin P (2013) Parkinson\u2019s Disease: Symptoms, Unmet\u00a0Needs and New Therapeutic Targets. Chapter 1 in: Martinex A, Gil C., editors,\u00a0Emerging Drugs and Targets for Parkinson\u2019s Disease. Cambridge, UK: The\u00a0Royal Society of Chemistry. pp 3\u201325.<br \/>\n4. Klein C, Westenberger A (2012) Genetics of Parkinson\u2019s disease. Cold Spring\u00a0Harb Perspect Med 2(1):a008888.<br \/>\n5. PINK1 Functions Medscape.com. http:\/\/www.medscape.com\/viewarticle\/711447_3. Accessed August 2015.<br \/>\n6. van Veen S, S\u00f8rensen DM, Holemans T et al. (2014) Cellular function and\u00a0pathological role of ATP13A2 and related P-type transport ATPases in\u00a0Parkinson\u2019s disease and other neurological disorders. Front Mol Neurosci 7:48.<br \/>\n7. Murphy KE, Gysbers AM, Abbott SK et al. (2014) Reduced glucocerebrosidase\u00a0is associated with increased -synuclein in sporadic Parkinson\u2019s disease. Brain.\u00a02014;137(Pt 3):834\u2013848.<br \/>\n8. Lesage S, Brice A (2009) Parkinson\u2019s disease: from monogenic forms to genetic\u00a0susceptibility factors. Hum Mol Genet 18(R1):R48\u2013R59.<br \/>\n9. Stefanis L (2012) -Synuclein in Parkinson\u2019s disease. Cold Spring Harb Perspect\u00a0Med 2(2):a009399.<br \/>\n10. Irwin DJ, Lee VM, Trojanowski JQ (2013) Parkinson\u2019s disease dementia:\u00a0convergence of -synuclein, tau and amyloid- pathologies. Nat Rev Neurosci\u00a014(9):626\u2013636.<br \/>\n11. Bendor JT, Logan TP, Edwards RH (2013) et al. The function of -synuclein.Neuron 79(6):1044\u20131066.<br \/>\n12. Lin X, Parisiadou L, Gu XL, Wang L et al. (2009) Leucine-rich repeat kinase 2\u00a0regulates the progression of neuropathology induced by Parkinson\u2019s-diseaserelated\u00a0mutant alpha-synuclein. Neuron 64(6):807\u2013827.<br \/>\n13. Hebron ML, Lonskaya I, Moussa CE (2013) Nilotinib reverses loss of dopamine\u00a0neurons and improves motor behavior via autophagic degradation of -synuclein\u00a0in Parkinson\u2019s disease models. Hum Mol Genet 22(16):3315\u20133328.<br \/>\n14. Brundin P, Atkin G, Lamberts JT (2015) Basic science breaks through: new\u00a0therapeutic advances in Parkinson\u2019s disease. Mov Disord 30(11):1521\u20131527.<br \/>\n15. Stefanis L. -Synuclein in Parkinson\u2019s disease. Cold Spring Harb Perspect Med.\u00a02012 Feb;2(2):a009399.<br \/>\n16. Chandra S, Gallardo G, Fern\u00e1ndez-Chac\u00f3n R et al. (2005) Alpha-synuclein\u00a0cooperates with CSPalpha in preventing neurodegeneration. Cell 123(3):383\u2013396.<br \/>\n17. Luk KC, Lee VM (2014) Modeling Lewy pathology propagation in Parkinson\u2019s\u00a0disease. Parkinsonism Relat Disord 20 Suppl 1:S85\u2013S87.<br \/>\n18. Prescription Medications. Parkinson\u2019s Disease Foundation. http:\/\/www.pdf.org\/en\/parkinson_prescription_meds. Accessed August 2015.<br \/>\n19. AlDakheel A, Kalia LV, Lang AE (2014) Pathogenesis-targeted, disease-modifying\u00a0therapies in Parkinson disease. Neurotherapeutics 11(1):6\u201323.<br \/>\n20. Atala A, Lanza R, editors (2013) Introduction to Stem Cells. In: Handbook of\u00a0Stem Cells. Volume 1 Pluripotent Stem Cells. Boston: Elsevier; 2013: 3.<br \/>\n21. Sandoe J, Eggan K (2013) Opportunities and challenges of pluripotent stem cell\u00a0neurodegenerative disease models. Nat Neurosci 16(7):780\u2013789.<br \/>\n22. Development of iPS From Donated Somatic Cells of Patients With Neurological\u00a0Diseases. ClinicalTrials.gov. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT00874783?term=%22parkinson%27s%22+AND+%22stem+cell%22&amp;rank=11. Accessed\u00a0August 2015.<br \/>\n23. Paulson HL, Albin RL (2011) Huntington\u2019s Disease: Clinical Features and Routes\u00a0to Therapy. In: Lo DC, Hughes RE, editors. Neurobiology of Huntington\u2019s\u00a0Disease: Applications to Drug Discovery. Boca Raton (FL): CRC Press<br \/>\n24. WHO. Genes and human disease. http:\/\/www.who.int\/genomics\/public\/geneticdiseases\/en\/index2.html#HD. Accessed August 2015.<br \/>\n25. Bates GP, Dorsey R, Gusella JF et al. (2015) Huntington disease. Nat Rev Dis\u00a0Primers 11\u201321.<br \/>\n26. ClinicalTrials.gov. VX15\/2503 Treatment for Huntington Disease (SIGNAL).\u00a0https:\/\/clinicaltrials.gov\/ct2\/show\/ NCT02481674?term=%22Huntington%22&amp;recr=Open&amp;no_unk=Y&amp;rank=15. Accessed August 2015.<br \/>\n27. Warby SC, Graham RK, Hayden MR (1998) Huntington Disease. In: Pagon RA,\u00a0Adam MP, Ardinger HH, et al., editors. GeneReviews [Internet]. Seattle (WA):\u00a0University of Washington, Seattle.<br \/>\n28. Prime View: HUNTINGTON DISEASE. Nature Reviews: Disease Primers.\u00a0http:\/\/www.nature.com\/public\/article-assets\/npg\/nrdp\/primeviews\/huntingtondisease-2015.pdf, 2015. Accessed August 2015.<br \/>\n29. Bear MF, Connors BW, Paradiso MA (2007) Neuroscience: Exploring the Brain.\u00a03rd ed. Philadelphia (PA): Lippincott Williams &amp; Wilkins.<br \/>\n30. Papoutsi M, Labuschagne I, Tabrizi SJ et al. (2014) The cognitive burden in\u00a0Huntington\u2019s disease: pathology, phenotype, and mechanisms of compensation.\u00a0Mov Disord 29(5):673\u2013683.<br \/>\n31. Kumar A, Kumar Singh S, Kumar V et al. (2015) Huntington\u2019s disease: an update\u00a0of therapeutic strategies. Gene 556(2):91\u201397.<br \/>\n32. Zuccato C, Valenza M, Cattaneo E (2010) Molecular mechanisms and potential\u00a0therapeutical targets in Huntington\u2019s disease. Physiol Rev 90(3):905\u2013981.<br \/>\n33. Pharm I. ISIS-HTTRx in a Phase 1\/2a clinical study in patients with HD. https:\/\/www.isispharm.com\/pipeline\/.<br \/>\n34. Shannon KM, Fraint A (2015) Therapeutic advances in Huntington\u2019s Disease.\u00a0Mov Disord 30(11):1539\u20131546.<br \/>\n35. Zizkova M, Sucha R, Tyleckova J et al. (2015) Proteome-wide analysis of neural\u00a0stem cell differentiation to facilitate transition to cell replacement therapies.\u00a0Expert Rev Proteomics 12(1):83\u201395.<br \/>\n36. Renton AE, Chi\u00f2 A, Traynor BJ (2014) State of play in amyotrophic lateral\u00a0sclerosis genetics. Nat Neurosci 17(1):17\u201323.<br \/>\n37. Swinnen B, Robberecht W (2014) The phenotypic variability of amyotrophic\u00a0lateral sclerosis. Nat Rev Neurol 10(11):661\u2013670.<br \/>\n38. Wijesekera LC, Leigh PN (2009) Amyotrophic lateral sclerosis. Orphanet J Rare\u00a0Dis i4:1\u201322.<br \/>\n39. Hyperreflexia. TheFreeDictionary.com. http:\/\/medical-dictionary.thefreedictionary.com\/hyperreflexia. Definition of hyperreflexia. Accessed August 2015.<br \/>\n40. Hypertonia. TheFreeDictionary.com. http:\/\/medical-dictionary.thefreedictionary.\u00a0com\/hypertonia. Accessed August 2015.<br \/>\n41. Kinsley L, Siddique T. Amyotrophic Lateral Sclerosis Overview. 2001 Mar 23\u00a0[Updated 2015 Feb 12]. In: Pagon RA, Adam MP, Ardinger HH et al., editors.\u00a0GeneReviews [Internet]. Seattle (WA): University of Washington, Seattle; 1993-2015.<br \/>\n42. Muscle Twitching (muscle fasciculations). MedlinePlus. http:\/\/www.nlm.nih.gov\/medlineplus\/ency\/article\/003296.htm. Accessed August 2015.<br \/>\n43. Hyporeflexia. ALS Association. http:\/\/www.alsa.org\/research\/glossary\/.\u00a0Accessed August 2015.<br \/>\n44. Lillo P, Garcin B, Hornberger M et al. (2010) Neurobehavioral features in\u00a0frontotemporal dementia with amyotrophic lateral sclerosis. Arch Neurol\u00a067(7):826\u2013830.<br \/>\n45. Bettencourt C, Houlden H (2015) Exome sequencing uncovers hidden pathways\u00a0in familial and sporadic ALS. Nat Neurosci 8(5):611\u2013613.<br \/>\n46. Turner BJ, Talbot K (2008) Transgenics, toxicity and therapeutics in rodent\u00a0models of mutant SOD1-mediated familial ALS. Prog Neurobiol 85(1):94\u2013134.<br \/>\n47. Committee on the Review of the Scientific Literature on Amyotrophic Lateral\u00a0Sclerosis in Veterans. Amyotrophic Lateral Sclerosis in Veterans: Review of the\u00a0Scientific Literature. Washington DC: The National Academies Press; 2006.<br \/>\n48. Gliosis. TheFreeDictionary.com. http:\/\/medical-dictionary.thefreedictionary.com\/gliosis. Accessed August 2015.<br \/>\n49. Mackenzie IR, Bigio EH, Ince PG et al. (2007) Pathological TDP-43 distinguishes\u00a0sporadic amyotrophic lateral sclerosis from amyotrophic lateral sclerosis with\u00a0SOD1 mutations. Ann Neurol 61(5):427\u2013434.<br \/>\n50. Vance C, Rogelj B, Hortob\u00e1gyi T et al. (2009) Mutations in FUS, an RNA\u00a0processing protein, cause familial amyotrophic lateral sclerosis type 6. Science\u00a0323(5918):1208\u20131211.<br \/>\n51. Kwiatkowski TJ Jr, Bosco DA, Leclerc AL et al. (2009) Mutations in the FUS\/TLS\u00a0gene on chromosome 16 cause familial amyotrophic lateral sclerosis. Science\u00a0323(5918):1205\u20131208.<br \/>\n52. Neumann M, Sampathu DM, Kwong LK et al. (2006) Ubiquitinated TDP-43 in\u00a0frontotemporal lobar degeneration and amyotrophic lateral sclerosis. Science\u00a0314(5796):130\u2013133.<br \/>\n53. Wijesekera LC, Leigh PN (2009) Amyotrophic lateral sclerosis. Orphanet J Rare\u00a0Dis 4:1\u201322,<br \/>\n54. The ALS Forum. New Findings on SOD1 Protein Properties Are Key Step\u00a0in Antisense Clinical Trials\u2014See more at: http:\/\/www.researchals.org\/page\/4832\/14730\/#sthash.p7SVrD6H.dpuf. http:\/\/www.researchals.org\/page\/4832\/14730\/. Accessed August 2015.<br \/>\n55. The ALS Association. New Award Will Lay Groundwork for C9orf72 Clinical\u00a0Trials. http:\/\/www.alsa.org\/news\/archive\/groundwork-for-c7orf72-trials.html.\u00a0Accessed August 2015.<br \/>\n56. Cytokinetics. Press Releases. Cytokinetics and the ALS association announce\u00a0awarding of grant for phase 3 clinical trial and biomarker research collaboration.\u00a0http:\/\/www.cytokinetics.com\/press_releases\/release\/pr_1436828630. Accessed\u00a0August 2015.<br \/>\n57. NEALS. A prospective, multicenter, randomized, double-blind, placebocontrolled,\u00a0parallel group, phase 2 study to compare the efficacy and safety of\u00a0masitinib versus placebo in the treatment of patients suffering from Amyotrophic\u00a0Lateral Sclerosis (ALS). http:\/\/www.alsconsortium.org\/trial.php?id=109.\u00a0Accessed August 2015.<br \/>\n58. ALSTDI. Masitinib Phase 3 Clinical Trial Update. http:\/\/www.alstdi.org\/news\/masitinib-phase-3-clinical-trial-update\/. Accessed August 2015.<br \/>\n59. NEALS. Ibudilast (MN-166) in Subjects With Amyotrophic Lateral Sclerosis (ALS)\u00a0(IBU-ALS-1201). http:\/\/www.alsconsortium.org\/trial.php?id=121. Accessed\u00a0August 2015.<br \/>\n60. NEALS. A Pilot Study of Inosine in ALS. http:\/\/www.alsconsortium.org\/trial.php?id=122. Accessed August 2015.<br \/>\n61. NEALS. A Phase 2, Randomized, Double Blind, Placebo Controlled Multicenter\u00a0Study to Evaluate Safety and Efficacy of Transplantation of Autologous\u00a0Mesenchymal Stem Cells Secreting Neurotrophic Factors (MSC-NTF) in Patients\u00a0With ALShttp:\/\/www.alsconsortium.org\/trial.php?id=126. Accessed August\u00a02015.<br \/>\n62. Neuralstem. Neuralstem Cell Therapy for ALS. http:\/\/www.neuralstem.com\/celltherapy-for-als. Accessed August 2015.<br \/>\n63. Tullman MJ (2013) Overview of the epidemiology, diagnosis, and disease\u00a0progression associated with multiple sclerosis. Am J Manag Care. 2013;19(2Suppl):S15\u2013S20.<br \/>\n64. Van der Walt A, Butzkeuven H, Kolbe S et al. (2010) Neuroprotection in\u00a0multiple sclerosis: a therapeutic challenge for the next decade. Pharmacol Ther\u00a0126(1):82\u201393.<br \/>\n65. Wilkins A, Scolding N (2008) Protecting axons in multiple sclerosis. Mult Scler\u00a014(8):1013\u20131025.<br \/>\n66. Olek MJ (2005) Differential Diagnosis, Clinical Features, and Prognosis of\u00a0Multiple Sclerosis. In: Olek MJ, editor. Multiple Sclerosis. Etiology, Diagnosis, and\u00a0New Treatment Strategies. United States: Humana Press, Inc.pp 15\u201353.<br \/>\n67. Demetriou M (2005) Multiple Sclerosis, Genetics, and Autoimmunity. In: Olek\u00a0MJ, ed. Multiple Sclerosis. Etiology, Diagnosis, and New Treatment Strategies.\u00a0United States: Humana Press, Inc; pp 103\u2013112.<br \/>\n68. Cree BAC (2014) Multiple sclerosis genetics. Hand Clin Neuro 122: 193\u2013209.<br \/>\n69. Ontaneda D , Hyland M, Cohen JA (2012) Multiple sclerosis: new insights in\u00a0pathogenesis and novel therapeutics. Annu Rev Med 63:389\u2013404.<br \/>\n70. Campagnolo DI, Vollmer TL. Multiple Sclerosis (Updated September 22,\u00a02010). eMedicine from WebMD. Available at: http:\/\/emedicine.medscape.com\/article\/310965-overview. Accessed March, 2011.<br \/>\n71. Oksenberg JR, Baranzimi SE, Hauser SL (2007) Biological concepts of multiple\u00a0sclerosis pathogenesis and relationship to treatment. In: Cohen JA, Rudick RA,\u00a0editors. Multiple Sclerosis Therapeutics, 3rd ed. United Kingdom: Informa UK\u00a0Ltd. pp 23\u201344.<br \/>\n72. Simon KC, Schmidt H, Loud S et al. (2015) Risk factors for multiple sclerosis,\u00a0neuromyelitis optica and transverse myelitis. Mult Scler 21(6):703\u2013709.<br \/>\n73. Lucchinetti CF, Parisi J, Bruck W (2014) The pathology of multiple sclerosis.\u00a0Neurol 23:77\u2013105.<br \/>\n74. Nair A, Frederick TJ, Miller SD (2008) Astrocytes in multiple sclerosis: a product\u00a0of their environment. Cell Mol Life Sci 65(17):2702\u20132720.<br \/>\n75. Neuhaus O, Archelos JJ, Hartung HP (2003) Immunomodulation in multiple\u00a0sclerosis: from immunosuppression to neuroprotection. Trends in Pharmacol Sci\u00a024(3):131\u2013138.<br \/>\n76. Haines JD, Inglese M, Casaccia P (2011) Axonal damage in multiple sclerosis Mt\u00a0Sinai J Med 78(2):231\u2013243.<br \/>\n77. Trapp BD, Nave KA (2008) Multiple sclerosis: an immune or neurodegenerative\u00a0disorder? Annu Rev Neurosci 31:247\u2013269.<br \/>\n78. Abbas AK, Lichtman AH, Pillai S (2005) Cellular and Molecular Immunology. 5th\u00a0Edition. Philadelphia (PA): Elsevier Saunders.<br \/>\n79. Wilkins A, Scolding N (2008) Protecting axons in multiple sclerosis. Mult Scler\u00a014(8);1013\u20131025.<br \/>\n80. Ellwardt E, Zipp F (2014) Molecular mechanisms linking neuroinflammation and\u00a0neurodegeneration in MS. Exp Neurol 262 Pt A:8\u201317.<br \/>\n81. Rinker II JR, Naismith RT, Cross AH (2006) Multiple Sclerosis: An Autoimmune\u00a0Disease of the Central Nervous System? In: Cook SD, editor. Handbook of\u00a0Multiple Sclerosis, 4th ed. New York (NY): Taylor &amp; Francis Group, LLC pp 95-112.<br \/>\n82. Fletcher JM, Lalor SJ, Sweeney CM et al. (2010) T cells in multiple sclerosis and\u00a0experimental autoimmune encephalomyelitis. Clin Exp Immunol 162(1):1\u201311.<br \/>\n83. Gilgun-Sherki Y, Melamed E, Offen D (2004) The role of oxidative stress in the\u00a0pathogenesis of multiple sclerosis: the need for effective antioxidant therapy. J\u00a0Neurol 251:261\u2013268.<br \/>\n84. Stys PK (2005) General mechanisms of axonal damage and its prevention. J\u00a0Neurol Sci 233(1\u20132):3\u201313.<br \/>\n85. Lassmann H (2014) Multiple sclerosis: lessons from molecular neuropathology.\u00a0Exp Neurol 262 Pt A:2\u20137.<br \/>\n86. Yaghmoor F, Noorsaeed A, Alsaggaf S et al. (2014) The Role of TREM2\u00a0in Alzheimer\u2019s disease and other neurological disorders. J Alzheimers Dis\u00a0Parkinsonism 4(5)pii:160.<br \/>\n87. Piccio L, Buonsanti C, Cella M (2008) Identification of soluble TREM-2 in\u00a0the cerebrospinal fluid and its association with multiple sclerosis and CNS\u00a0inflammation. Brain 131(Pt 11):3081\u20133091.<br \/>\n88. Zhai D, Lee FH, D\u2019Souza C et al. (2015) Blocking GluR2-GAPDH ameliorates\u00a0experimental autoimmune encephalomyelitis. Ann Clin Transl Neurol 2(4):388\u2013400.<br \/>\n89. Sand IBK and Krieger S. Emerging Strategies for the Treatment of Multiple\u00a0Sclerosis. Future Neurology. 2012;7(2):193-207. http:\/\/www.medscape.com\/viewarticle\/760849_5. Accessed August 2015.<br \/>\n90. Di Padova F, Ryffel B, Quesniaux V (2003). IL-17A Family, Receptors,\u00a0Proinflammatory Effects, and Production. In: Quesniaux V, Ryffel B, Di Padova\u00a0R (editors), IL-17, IL-22 and Their Producing Cells: Role in Inflammation and\u00a0Autoimmunity. Second Edition. New York: Springer Basel pp 37\u201354.<br \/>\n91. Jin W, Dong C (2013) IL-17 cytokines in immunity and inflammation. Emerg\u00a0Microbes Infect 2(9):e60.<br \/>\n92. Gaweco A, Palmer S, Shamilov R et al (2013) EAE disease prevention by a\u00a0potent oral ROR t inverse agonist INV-17: a promising safe and efficacious MS\u00a0treatment. J Neurol Sci 333:e362\u2013e363.<br \/>\n93. Racke MK, Yang Y, Lovett-Racke AE (2014) Is T-bet a potential therapeutic\u00a0target in multiple sclerosis? J Interferon Cytokine Res 34(8):623\u2013632.\u00a094. Sabat R, Ouyang W, Wolk K (2014) Therapeutic opportunities of the IL-22\u2013IL-22R1 system. Nat Rev Drug Discov 13(1):21\u201338.<br \/>\n95. Perriard G, Mathias A, Enz L et al. (2015) Interleukin-22 is increased in multiple\u00a0sclerosis patients and targets astrocytes. J Neuroinflammation 16;12:119.<br \/>\n96. Medications. National Multiple Sclerosis Society. http:\/\/www.nationalmssociety.\u00a0org\/Treating-MS\/Medications. Accessed August 2015.<br \/>\n97. Copaxone. National Multiple Sclerosis Society. http:\/\/www.nationalmssociety.org\/Treating-MS\/Medications\/Copaxone. Accessed August 2015.<br \/>\n98. Copaxone (Glatiramer Acetate) Injection. RXList.com. http:\/\/www.rxlist.com\/copaxone-drug.htm. Accessed August 2015.<br \/>\n99. Kieseier BC (2011) The mechanism of action of interferon- in relapsing multiple\u00a0sclerosis. CNS Drugs 25(6):491\u2013502.<br \/>\n100. Aubagio. National Multiple Sclerosis Society. http:\/\/www.nationalmssociety.org\/Treating-MS\/Medications\/Aubagio. Accessed August 2015.<br \/>\n101. Valentine WJ, Godwin VI, Osborne DA et al. (2011) FTY720 (Gilenya) phosphate\u00a0selectivity of sphingosine-1-phosphate receptor subtype 1 (S1P1) G proteincoupled\u00a0receptor requires motifs in intracellular loop 1 and transmembrane\u00a0domain 2. J Biol Chem 286(35):30513\u201330525.<br \/>\n102. Gilenya. National Multiple Sclerosis Society. http:\/\/www.nationalmssociety.org\/Treating-MS\/Medications\/Gilenya. Accessed August 2015.<br \/>\n103. Nguyen T, Nioi P, Pickett CB (2009) The Nrf2-antioxidant response element\u00a0signaling pathway and its activation by oxidative stress. J Biol Chem\u00a0284(20):13291\u201313295.<br \/>\n104. Minagar A, Alexander JS, Sahrajan MA et al. (2010) Alemtuzumab and multiple\u00a0sclerosis: therapeutic application. Expert Opin Biol Ther 10(3):421\u2013429.<br \/>\n105. Hartung H-P et al. (2002) Mitoxantrone In Progressive Multiple Sclerosis: A\u00a0Placebo-Controlled, Double-Blind, Randomised, Multicentre Trial. Lancet\u00a0360:2018\u20132025.<br \/>\n106. Tysabri. Proposed Mechanism of Action. https:\/\/www.tysabrihcp.com\/en_us\/home\/clinical-overview\/moa.html. Accessed August 2015.<br \/>\n107. Blight AR, Henney HR 3rd, Cohen R (2014) Development of dalfampridine,\u00a0a novel pharmacologic approach for treating walking impairment in multiple\u00a0sclerosis. Ann N Y Acad Sci 1329:33\u201344.<br \/>\n108. Mullard A (2011) Success of immunomodulators in MS shifts discovery focus to\u00a0neuroprotection. Nat Rev Drug Discov 1;10(12):885\u2013887.<br \/>\n109. Wingerchuk DM, Carter JL (2014) Multiple sclerosis: current and emerging\u00a0disease-modifying therapies and treatment strategies. Mayo Clinic Proc\u00a089(2):225\u2013240.<br \/>\n110. Safety and Efficacy of Intravenous Autologous Mesenchymal Stem Cells for\u00a0MS: a Phase 2 Proof of Concept Study (MESCAMS). ClinicalTrials.gov. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02239393. Accessed August 2015.<br \/>\n111. Xiao J, Yang R, Biswas S et al. (2015) Mesenchymal stem cells and induced\u00a0pluripotent stem cells as therapies for multiple sclerosis. Int J Mol Sci\u00a016(5):9283\u20139302.<br \/>\n<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>1\u3064\u306e\u795e\u7d4c\u5909\u6027\u75c7\u72b6\u3092\u4ed6\u306e\u660e\u78ba\u306b\u7570\u306a\u308b\u75c7\u72b6\u3068\u8b58\u5225\u3057\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u5883\u754c\u7dda\u306f\u3088\u304f\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u304a\u3088\u3073\u904b\u52d5\u6a5f\u80fd\u969c\u5bb3\u306e\u60a3\u8005\u306f\u3001\u9ad8\u983b\u5ea6\u30671\u3064\u4ee5\u4e0a\u306e\u660e\u78ba\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u795e\u7d4c\u5b66\u7684\u75c5\u72b6\u304c\u7591\u308f\u308c\u3001\u307e\u305f\u8907\u6570\u306e\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u306e\u5b58\u5728<\/p>\n","protected":false},"author":988,"featured_media":4377,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[32],"division":[],"class_list":{"0":"post-1124","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-antibody","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\" \/>\n<meta property=\"og:description\" content=\"1\u3064\u306e\u795e\u7d4c\u5909\u6027\u75c7\u72b6\u3092\u4ed6\u306e\u660e\u78ba\u306b\u7570\u306a\u308b\u75c7\u72b6\u3068\u8b58\u5225\u3057\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u5883\u754c\u7dda\u306f\u3088\u304f\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u304a\u3088\u3073\u904b\u52d5\u6a5f\u80fd\u969c\u5bb3\u306e\u60a3\u8005\u306f\u3001\u9ad8\u983b\u5ea6\u30671\u3064\u4ee5\u4e0a\u306e\u660e\u78ba\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u795e\u7d4c\u5b66\u7684\u75c5\u72b6\u304c\u7591\u308f\u308c\u3001\u307e\u305f\u8907\u6570\u306e\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u306e\u5b58\u5728\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-12-20T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-27T08:47:05+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"830\" \/>\n\t<meta property=\"og:image:height\" content=\"429\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"75\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\",\"datePublished\":\"2018-12-20T15:00:00+00:00\",\"dateModified\":\"2023-12-27T08:47:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/\"},\"wordCount\":2554,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-2.png\",\"keywords\":[\"\u6297\u4f53\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/\",\"name\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-2.png\",\"datePublished\":\"2018-12-20T15:00:00+00:00\",\"dateModified\":\"2023-12-27T08:47:05+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-2.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/neuron-modfied-2.png\",\"width\":830,\"height\":429,\"caption\":\"\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/neuro_disease3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3","og_description":"1\u3064\u306e\u795e\u7d4c\u5909\u6027\u75c7\u72b6\u3092\u4ed6\u306e\u660e\u78ba\u306b\u7570\u306a\u308b\u75c7\u72b6\u3068\u8b58\u5225\u3057\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u5883\u754c\u7dda\u306f\u3088\u304f\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8a8d\u77e5\u6a5f\u80fd\u969c\u5bb3\u304a\u3088\u3073\u904b\u52d5\u6a5f\u80fd\u969c\u5bb3\u306e\u60a3\u8005\u306f\u3001\u9ad8\u983b\u5ea6\u30671\u3064\u4ee5\u4e0a\u306e\u660e\u78ba\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u795e\u7d4c\u5b66\u7684\u75c5\u72b6\u304c\u7591\u308f\u308c\u3001\u307e\u305f\u8907\u6570\u306e\u75c5\u614b\u30de\u30fc\u30ab\u30fc\u306e\u5b58\u5728","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-12-20T15:00:00+00:00","article_modified_time":"2023-12-27T08:47:05+00:00","og_image":[{"width":830,"height":429,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","type":"image\/png"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"75\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3","datePublished":"2018-12-20T15:00:00+00:00","dateModified":"2023-12-27T08:47:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/"},"wordCount":2554,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","keywords":["\u6297\u4f53"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/","name":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","datePublished":"2018-12-20T15:00:00+00:00","dateModified":"2023-12-27T08:47:05+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","width":830,"height":429,"caption":"\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/neuro_disease3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u795e\u7d4c\u5909\u6027\u75be\u60a3\u7814\u7a76\u3092\u5b66\u307c\u30463\u3011\u4ed6\u306e\u4e3b\u8981\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":32,"label":"\u6297\u4f53"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png",760,393,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":32,"name":"\u6297\u4f53","slug":"antibody","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":31,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":1124,"position":0},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":1124,"position":1},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":1124,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":1124,"position":3},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":1124,"position":4},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":1124,"position":5},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/neuron-modfied-2.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1124"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1124\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4377"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1124"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1124"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1124"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}