{"id":11241,"date":"2022-03-11T09:00:24","date_gmt":"2022-03-11T00:00:24","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=11241"},"modified":"2022-04-05T15:05:39","modified_gmt":"2022-04-05T06:05:39","slug":"dna_microarray_ma_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/","title":{"rendered":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f"},"content":{"rendered":"<p>\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3001\u67d3\u8272\u4f53\u30b3\u30d4\u30fc\u6570\u89e3\u6790\u3001SNP\u89e3\u6790\u306a\u3069\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308bDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304b\u3054\u5b58\u3058\u3067\u3057\u3087\u3046\u304b\u3002\u5b9f\u9a13\u81ea\u4f53\u306f\u53d7\u8a17\u89e3\u6790\u306b\u4f9d\u983c\u3057\u3066\u3044\u3066\u3001\u751f\u30c7\u30fc\u30bf\u3084\u89e3\u6790\u7d50\u679c\u3057\u304b\u898b\u305f\u3053\u3068\u304c\u306a\u3044\u3068\u3044\u3046\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u8ad6\u6587\u3084\u53e3\u6f14\u306eMaterials and Method\u3067\u8a73\u7d30\u306b\u8a18\u8ff0\u3059\u308b\u3053\u3068\u306f\u306a\u3044\u306b\u3057\u3066\u3082\u3001\u5b9f\u9a13\u7cfb\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u5f97\u3089\u308c\u308b\u30c7\u30fc\u30bf\u306e\u89e3\u91c8\u3084\u7406\u89e3\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u666e\u6bb5\u3068\u7570\u306a\u308b\u30c7\u30fc\u30bf\u304c\u5f97\u3089\u308c\u305f\u3068\u304d\u3001\u53d7\u8a17\u89e3\u6790\u4f1a\u793e\u3068\u306e\u8b70\u8ad6\u3092\u5177\u4f53\u7684\u306b\u9032\u3081\u308b\u52a9\u3051\u306b\u306a\u308b\u3068\u8003\u3048\u307e\u3059\u3002\u672c\u7a3f\u3067\u306f\u3001\u5f53\u793e\u306e\u88fd\u54c1\u3092\u4f8b\u306bDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u305d\u306e\u5b9f\u9a13\u3092\u884c\u3046\u305f\u3081\u306e\u6a5f\u5668\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u305d\u306e\u30b7\u30b9\u30c6\u30e0<\/h2>\n<p>DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u30aa\u30ea\u30b4\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3001cDNA\u307e\u305f\u306fBAC\u30af\u30ed\u30fc\u30f3DNA\uff08\u3053\u308c\u3092\u30d7\u30ed\u30fc\u30d6\u3068\u547c\u3073\u307e\u3059\uff09\u3092\u30ac\u30e9\u30b9\u306a\u3069\u306e\u57fa\u677f\u4e0a\u306b\u9ad8\u5bc6\u5ea6\u306b\u6574\u5217\u56fa\u5b9a\u3057\u305f\u30c4\u30fc\u30eb\u3067\u3059\u3002DNA\u30c1\u30c3\u30d7\uff08DNA chip\uff09\u3068\u547c\u3070\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u308c\u306b\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u62bd\u51fa\u3057\u305fRNA\u3084DNA\uff08\u304b\u3089\u5897\u5e45\u3084\u30e9\u30d9\u30ea\u30f3\u30b0\u3092\u65bd\u3057\u305f\u3082\u306e\uff09\u3092\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3057\u3001\u305d\u306e\u5f8c\u306f\u3001\u6d17\u6d44\u30fb\u67d3\u8272\u3092\u884c\u3063\u3066\u3001\u57fa\u76e4\u90e8\u5206\u3092\u30b9\u30ad\u30e3\u30f3\u3057\u3066\u753b\u50cf\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u753b\u50cf\u30c7\u30fc\u30bf\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u7c21\u4fbf\u306b\u4f4e\u30b3\u30b9\u30c8\u3067\u3001\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u72b6\u6cc1\u3084SNP\u306e\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u306e\u4e00\u89a7\u8868\u30c7\u30fc\u30bf\u3092\u4f5c\u6210\u3057\u3066\u3001\u7db2\u7f85\u7684\u306a\u89e3\u6790\u3092\u884c\u3048\u308b\u306e\u304c\u5229\u70b9\u3067\u3059\u3002<br \/>\nDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u304c\u767b\u5834\u3057\u305f\u306e\u306f1990\u5e74\u4ee3\u521d\u982d\u3067\u3001\u3053\u308c\u307e\u3067\u5e83\u304f\u4f7f\u308f\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u73fe\u5728\u3067\u306fNGS\u3084\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306a\u3069\u3001\u4ed6\u306e\u30c4\u30fc\u30eb\u3067\u3082\u540c\u69d8\u306e\u5b9f\u9a13\u3092\u884c\u3048\u308b\u305f\u3081\u3001\u5b9f\u969b\u306b\u76ee\u306b\u3057\u305f\u65b9\u306f\u5c11\u306a\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n<p>Applied Biosystems\u2122 GeneChip\u2122 \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u65e7\u30a2\u30d5\u30a3\u30e1\u30c8\u30ea\u30af\u30b9\uff08Affymetrix\uff09\u793e\u3001\u73fe\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u793e\u306e\u88fd\u54c1\u3067\u3059\u3002\u5b9f\u9a13\u306f\u3001\u3053\u306eGeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068Applied Biosystems\u2122 GeneChip\u2122 Scanner 3000 7G System\u3092\u7528\u3044\u3066\u884c\u3044\u307e\u3059\u3002GeneChip Scanner 3000 7G System\u306f\u3001GeneChip \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u5c02\u7528\u306e\u30b7\u30b9\u30c6\u30e0\u3067\u3001\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u30aa\u30fc\u30d6\u30f3\uff08Applied Biosystems\u2122 GeneChip\u2122 Hybridization Oven 645\uff09\u3001\u305d\u306e\u5f8c\u306e\u6d17\u6d44\u304a\u3088\u3073\u30e9\u30d9\u30ea\u30f3\u30b0\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u67d3\u8272\u3059\u308b\u6a5f\u5668\uff08Applied Biosystems\u2122 GeneChip\u2122 Fluidics Station 450\uff09\u3001\u305d\u306e\u5f8c\u306b\u753b\u50cf\u3092\u53d6\u5f97\u3059\u308b\u30b9\u30ad\u30e3\u30ca\u30fc\uff08Applied Biosystems\u2122 GeneChip\u2122 Scanner 3000 7G\uff09\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u8a73\u3057\u304f\u306f\u3001\u5f53\u793e\u30db\u30fc\u30e0\u30da\u30fc\u30b8<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-education\/microarray-overview.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB#about\" target=\"_blank\" rel=\"noopener\">\u300c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u624b\u5f15\u304d &gt;&gt; \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u300d<\/a> \u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_11242\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11242\" class=\"size-large wp-image-11242\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/533ecc794d3e5247293d442f5fcaf29c-1024x500.png\" alt=\"\" width=\"760\" height=\"371\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/533ecc794d3e5247293d442f5fcaf29c-1024x500.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/533ecc794d3e5247293d442f5fcaf29c-300x147.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/533ecc794d3e5247293d442f5fcaf29c-768x375.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/533ecc794d3e5247293d442f5fcaf29c.png 1163w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11242\" class=\"wp-caption-text\">\u56f31. GeneChip\u30b7\u30b9\u30c6\u30e0<\/p><\/div>\n<h2>GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4<\/h2>\n<div id=\"attachment_11243\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11243\" class=\"size-large wp-image-11243\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fe441187fe774dac106d8df7403f0eed-1024x613.png\" alt=\"\" width=\"760\" height=\"455\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fe441187fe774dac106d8df7403f0eed-1024x613.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fe441187fe774dac106d8df7403f0eed-300x180.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fe441187fe774dac106d8df7403f0eed-768x460.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fe441187fe774dac106d8df7403f0eed.png 1167w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11243\" class=\"wp-caption-text\">\u56f32. GeneChip \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306e\u30aa\u30ea\u30b4\u30d7\u30ed\u30fc\u30d6\u306e\u914d\u7f6e<\/p><\/div>\n<p>GeneChip \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001DNA\u30d7\u30ed\u30fc\u30d6\u3092\u57fa\u677f\u4e0a\u306b\u914d\u7f6e\u3059\u308b\u65b9\u6cd5\u304c\u3001\u4ed6\u306eDNA\u30c1\u30c3\u30d7\u3068\u306f\u7570\u306a\u3063\u3066\u3044\u308b\u3053\u3068\u304c\uff11\u3064\u306e\u7279\u5fb4\u3067\u3059\u304c\u3001\u914d\u7f6e\u3055\u308c\u305f\u9762\u304c\u5185\u5074\u306b\u306a\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u70b9\u3082\u4ed6\u3068\u7570\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>GeneChip \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u88fd\u9020\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001\u5f53\u793e\u30db\u30fc\u30e0\u30da\u30fc\u30b8<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-education\/microarray-overview.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB#about\" target=\"_blank\" rel=\"noopener\">\u300c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u624b\u5f15\u304d &gt;&gt; \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u300d<\/a> \u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_11244\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11244\" class=\"size-large wp-image-11244\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-1024x768.jpg\" alt=\"\" width=\"760\" height=\"570\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-1024x768.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-300x225.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-768x576.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-1536x1152.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/photo_3-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11244\" class=\"wp-caption-text\">\u56f33. GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u8868\u9762\u3068\u88cf\u9762<\/p><\/div>\n<p>\u8868\u9762\u306e\u4e2d\u592e\u3001\u6b63\u65b9\u5f62\u306e\u30ac\u30e9\u30b9\u9762\u306bDNA\u30d7\u30ed\u30fc\u30d6\u304c\u5408\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u305d\u308c\u306f\u5185\u5074\u306e\u9762\u306b\u306a\u308a\u307e\u3059\u3002\u4e2d\u306f\u7a7a\u6d1e\u306b\u306a\u3063\u3066\u304a\u308a\u3001\u30e9\u30d9\u30ea\u30f3\u30b0\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306f\u88cf\u9762\u306e\u7a74\u304b\u3089\u6ce8\u5165\u3057\u307e\u3059\u3002<br \/>\n\u88cf\u9762\u4e2d\u592e\u306e\u5927\u304d\u306a\u304f\u307c\u307f\u306f\u3001Fluidics Station\u306e\u30d2\u30fc\u30bf\u30fc\u304c\u53ce\u307e\u308b\u90e8\u5206\u3067\u3059\u3002\u305d\u306e\u30d2\u30fc\u30bf\u30fc\u3067\u6d17\u6d44\u30fb\u67d3\u8272\u6642\u306e\u6e29\u5ea6\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3057\u307e\u3059\u3002<br \/>\n\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3059\u308b\u306e\u306f\u3001\u8d64\u8272\u306e\u30b4\u30e0\u304c\u898b\u3048\u3066\u3044\u308b\u5c0f\u3055\u3044\u65b9\u306e\u7a74\u3067\u3059\uff08\u3053\u308c\u3092\u30bb\u30d7\u30bf\u3068\u547c\u3073\u307e\u3059\uff09\u3002\u5185\u90e8\u306f\u5bc6\u9589\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u6ce8\u5165\u6642\u3001\u7247\u65b9\u306b\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u3092\u633f\u3057\u3066\u7a7a\u6c17\u304c\u901a\u308b\u3088\u3046\u306b\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_11245\" style=\"width: 281px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11245\" class=\"wp-image-11245 size-medium\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/2d5ec3e1cdac4e2cb7c13da5f8a59926-271x300.jpg\" alt=\"\" width=\"271\" height=\"300\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/2d5ec3e1cdac4e2cb7c13da5f8a59926-271x300.jpg 271w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/2d5ec3e1cdac4e2cb7c13da5f8a59926.jpg 650w\" sizes=\"auto, (max-width: 271px) 100vw, 271px\" \/><p id=\"caption-attachment-11245\" class=\"wp-caption-text\">\u56f34. GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165<\/p><\/div>\n<p>\u4e0a\u306e\u7a74\u306b\u306f\u3001\u7a7a\u6c17\u304c\u901a\u308b\u3088\u3046\u306b\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u3092\u3042\u3089\u304b\u3058\u3081\u633f\u3057\u3066\u304a\u304d\u3001\u4e0b\u306e\u7a74\u304b\u3089\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_11246\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11246\" class=\"size-large wp-image-11246\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45-1024x570.png\" alt=\"\" width=\"760\" height=\"423\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45-1024x570.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45-300x167.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45-768x427.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45-450x250.png 450w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/1e25d4b708b5eba026cca75a1f6d0b45.png 1113w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11246\" class=\"wp-caption-text\">\u56f35. GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u5185\u90e8\u306e\u69d8\u5b50<\/p><\/div>\n<p>\u3053\u306e\u3088\u3046\u306a\u69cb\u9020\u306b\u306a\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u3092GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u3068\u304d\u306b\u3001\u30d7\u30ed\u30fc\u30d6\u3092\u9ad8\u5bc6\u5ea6\u306b\u6574\u5217\u56fa\u5b9a\u3055\u305b\u3066\u3044\u308b\u9762\u3092\u50b7\u3064\u3051\u308b\u5fc3\u914d\u304c\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<h2>\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u7528\u30aa\u30fc\u30d6\u30f3 GeneChip Hybridization Oven 645<\/h2>\n<p>GeneChip Hybridization Oven 645\u3067\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306e\u30d7\u30ed\u30fc\u30d6\u3068\u30e9\u30d9\u30ea\u30f3\u30b0\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u7d50\u5408\u3055\u305b\u307e\u3059\u3002\u3053\u308c\u3092\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3068\u547c\u3073\u307e\u3059\u3002<\/p>\n<div id=\"attachment_11247\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11247\" class=\"size-large wp-image-11247\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/c876cd061da4d7d2d0b9ce635d4e4da9-1024x462.png\" alt=\"\" width=\"760\" height=\"343\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/c876cd061da4d7d2d0b9ce635d4e4da9-1024x462.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/c876cd061da4d7d2d0b9ce635d4e4da9-300x135.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/c876cd061da4d7d2d0b9ce635d4e4da9-768x346.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/c876cd061da4d7d2d0b9ce635d4e4da9.png 1311w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11247\" class=\"wp-caption-text\">\u56f36. \u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3<\/p><\/div>\n<div id=\"attachment_11248\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11248\" class=\"size-large wp-image-11248\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/63b67d3810fb362dfb20863ba4c50e11-998x1024.jpg\" alt=\"\" width=\"760\" height=\"780\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/63b67d3810fb362dfb20863ba4c50e11-998x1024.jpg 998w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/63b67d3810fb362dfb20863ba4c50e11-292x300.jpg 292w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/63b67d3810fb362dfb20863ba4c50e11-768x788.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/63b67d3810fb362dfb20863ba4c50e11.jpg 1472w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11248\" class=\"wp-caption-text\">\u56f37. GeneChip Hybridization Oven 645<\/p><\/div>\n<p>\u30aa\u30fc\u30d6\u30f3\u306fGeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u5c02\u7528\u306e\u3082\u306e\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u5165\u308c\u308b\u30c8\u30ec\u30a4\u3068\u305d\u306e\u30c8\u30ec\u30a4\u3092\u53d6\u308a\u4ed8\u3051\u308b\u56de\u8ee2\u53f0\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_11249\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11249\" class=\"size-large wp-image-11249\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/a3c805d0994e890c9bdcc30ca8e74b8f-1024x592.jpg\" alt=\"\" width=\"760\" height=\"439\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/a3c805d0994e890c9bdcc30ca8e74b8f-1024x592.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/a3c805d0994e890c9bdcc30ca8e74b8f-300x173.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/a3c805d0994e890c9bdcc30ca8e74b8f-768x444.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/a3c805d0994e890c9bdcc30ca8e74b8f.jpg 1090w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11249\" class=\"wp-caption-text\">\u56f38-1. \u30aa\u30fc\u30d6\u30f3\u5185\u306e\u56de\u8ee2\u53f0\u306b\u30e9\u30c3\u30af\u3092\u56fa\u5b9a<\/p><\/div>\n<div id=\"attachment_11250\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11250\" class=\"size-large wp-image-11250\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/6ec4dd90789312a46d01cf11fc926376-1024x636.jpg\" alt=\"\" width=\"760\" height=\"472\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/6ec4dd90789312a46d01cf11fc926376-1024x636.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/6ec4dd90789312a46d01cf11fc926376-300x186.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/6ec4dd90789312a46d01cf11fc926376-768x477.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/6ec4dd90789312a46d01cf11fc926376.jpg 1051w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11250\" class=\"wp-caption-text\">\u56f38-2. \u30aa\u30fc\u30d6\u30f3\u5185\u306e\u56de\u8ee2\u53f0\u306b\u30e9\u30c3\u30af\u3092\u56fa\u5b9a<\/p><\/div>\n<p>\u30c8\u30ec\u30a4\u3092\u56de\u8ee2\u53f0\u306b\u53d6\u308a\u4ed8\u3051\u305f\u306e\u3061\u3001\u843d\u4e0b\u9632\u6b62\u306e\u305f\u3081\u4ed8\u5c5e\u306e\u91d1\u5c5e\u30af\u30ea\u30c3\u30d7\u3067\u5f15\u3063\u639b\u3051\u3066\u30e9\u30c3\u30af\u3092\u3057\u3063\u304b\u308a\u56fa\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<p>GeneChip Hybridization Oven 645\u306f\u3001\u540c\u6642\u306b64\u679a\u306eGeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u5165\u308c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3063\u3066\u3044\u308b\u9593\u3001GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u3067\u56de\u8ee2\u3057\u307e\u3059\uff08\u901a\u5e381\u5206\u9593\u306b60\u56de\u8ee2\uff09\u3002\u3053\u3046\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6e80\u904d\u306a\u304f\u30d7\u30ed\u30fc\u30d6\u304c\u56fa\u5b9a\u5316\u3055\u308c\u305f\u57fa\u677f\u4e0a\u306b\u884c\u304d\u6e21\u308a\u307e\u3059\u3002<\/p>\n<h2>\u81ea\u52d5\u6d17\u6d44\u30fb\u67d3\u8272\u88c5\u7f6e\uff08GeneChip Fluidics Station 450\uff09<\/h2>\n<div id=\"attachment_11251\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11251\" class=\"size-large wp-image-11251\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/ca0295e0aaae4d393e0d15d9bd9f1150-1024x494.png\" alt=\"\" width=\"760\" height=\"367\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/ca0295e0aaae4d393e0d15d9bd9f1150-1024x494.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/ca0295e0aaae4d393e0d15d9bd9f1150-300x145.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/ca0295e0aaae4d393e0d15d9bd9f1150-768x371.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/ca0295e0aaae4d393e0d15d9bd9f1150.png 1225w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11251\" class=\"wp-caption-text\">\u56f39. GeneChip Fluidics Station 450\u3067\u6d17\u6d44\u30fb\u67d3\u8272<\/p><\/div>\n<p>GeneChip Fluidics Station 450\u3067\u306f\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u4e0a\u306e\u30d7\u30ed\u30fc\u30d6\u3068\u975e\u7279\u7570\u7684\u306a\u7d50\u5408\u3092\u3057\u3066\u3044\u308b\u6838\u9178\u3092\u6d17\u6d44\u3057\u3066\u3001\u30d3\u30aa\u30c1\u30f3\u3092\u86cd\u5149\u8272\u7d20\u3067\u67d3\u8272\u3059\u308b\u3053\u3068\u3067\u3001\u7279\u7570\u7684\u306b\u7d50\u5408\u3057\u3066\u3044\u308b\u6838\u9178\u3092\u691c\u51fa\u3067\u304d\u308b\u3088\u3046\u306b\u3057\u307e\u3059\u3002<br \/>\n\u3053\u306e\u6a5f\u5668\u3082GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u5c02\u7528\u3067\u3059\u3002<\/p>\n<div id=\"attachment_11252\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11252\" class=\"size-large wp-image-11252\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12-1024x629.jpg\" alt=\"\" width=\"760\" height=\"467\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12-1024x629.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12-300x184.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12-768x472.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg 1172w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11252\" class=\"wp-caption-text\">\u56f310. GeneChip Fluidics Station 450<\/p><\/div>\n<div id=\"attachment_11254\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11254\" class=\"wp-image-11254 size-large\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fa5a810e89988ae20e160a83d8ddc186-1024x386.jpg\" alt=\"\" width=\"760\" height=\"286\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fa5a810e89988ae20e160a83d8ddc186-1024x386.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fa5a810e89988ae20e160a83d8ddc186-300x113.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fa5a810e89988ae20e160a83d8ddc186-768x289.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/fa5a810e89988ae20e160a83d8ddc186.jpg 1280w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11254\" class=\"wp-caption-text\">\u56f311. \u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3001GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4, \u8a66\u85ac\u306e\u8a2d\u7f6e\u5834\u6240<\/p><\/div>\n<p>\u5411\u304b\u3063\u3066\u53f3\u5074\u306e\u30dc\u30c8\u30eb\u306b\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u3001Wash Block\u3068\u547c\u3070\u308c\u308b\u7b87\u6240\u306bGeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u3001\u305d\u3057\u3066\u3001\u67d3\u8272\u8a66\u85ac\u3092\u3044\u308c\u305f\u30c1\u30e5\u30fc\u30d6\u3092\u30cb\u30fc\u30c9\u30eb\u304c\u4e0b\u308a\u3066\u304f\u308b\u7b87\u6240\u306b\u30bb\u30c3\u30c8\u3057\u307e\u3059\u3002<br \/>\n\u30cf\u30f3\u30ba\u30aa\u30f3\u306e\u64cd\u4f5c\u306f\u4ee5\u4e0a\u3067\u3001\u5b9f\u969b\u306e\u6d17\u6d44\u30fb\u67d3\u8272\u306e\u5de5\u7a0b\u306f\u6a5f\u5668\u304c\u884c\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u64cd\u4f5c\u8005\u306b\u3088\u308b\u7d50\u679c\u306e\u3070\u3089\u3064\u304d\u304c\u6392\u9664\u3055\u308c\u3001\u518d\u73fe\u6027\u306e\u9ad8\u3044\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<h2>\u30b9\u30ad\u30e3\u30ca\u30fc\uff08GeneChip Scanner 3000 7G\uff09<\/h2>\n<div id=\"attachment_11255\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11255\" class=\"size-large wp-image-11255\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/0d03519d9531c929e419c8f3b36df741-1024x432.png\" alt=\"\" width=\"760\" height=\"321\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/0d03519d9531c929e419c8f3b36df741-1024x432.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/0d03519d9531c929e419c8f3b36df741-300x127.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/0d03519d9531c929e419c8f3b36df741-768x324.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/0d03519d9531c929e419c8f3b36df741.png 1109w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-11255\" class=\"wp-caption-text\">\u56f312. \u5c02\u7528\u306e\u30b9\u30ad\u30e3\u30ca\u30fc\u306b\u3088\u308b\u86cd\u5149\u767a\u5149\u306e\u8aad\u307f\u53d6\u308a<\/p><\/div>\n<div id=\"attachment_11256\" style=\"width: 920px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11256\" class=\"size-full wp-image-11256\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/b55ceed38dbc3edd81bff422ffae7446.png\" alt=\"\" width=\"910\" height=\"638\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/b55ceed38dbc3edd81bff422ffae7446.png 910w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/b55ceed38dbc3edd81bff422ffae7446-300x210.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/b55ceed38dbc3edd81bff422ffae7446-768x538.png 768w\" sizes=\"auto, (max-width: 910px) 100vw, 910px\" \/><p id=\"caption-attachment-11256\" class=\"wp-caption-text\">\u56f313. GeneChip Scanner 3000 7G 2\u3064\u306e\u30e2\u30c7\u30eb<\/p><\/div>\n<p>GeneChip Scanner 3000 7G\u306b\u306f\u3001\u30aa\u30fc\u30c8\u30ed\u30fc\u30c0\u30fc\u4ed8\u304d\u3067\u6700\u5927 48\u679a\u306e\u30a2\u30ec\u30a4\u3092\u4e00\u5ea6\u306b\u5b8c\u5168\u81ea\u52d5\u3067\u30b9\u30ad\u30e3\u30f3\u53ef\u80fd\u306a\u30e2\u30c7\u30eb\u30681\u30a2\u30ec\u30a4\u305a\u3064\u30b9\u30ad\u30e3\u30f3\u3059\u308b\u30e2\u30c7\u30eb\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30aa\u30fc\u30c8\u30ed\u30fc\u30c0\u30fc\u306e\u53d6\u308a\u4ed8\u3051\u3084\u53d6\u308a\u5916\u3057\u306f\u3001\u30b5\u30fc\u30d3\u30b9\u30a8\u30f3\u30b8\u30cb\u30a2\u304c\u884c\u3044\u307e\u3059\u304c\u3001\u30b9\u30ad\u30e3\u30ca\u30fc\u672c\u4f53\u90e8\u5206\u306b\u9055\u3044\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u86cd\u5149\u767a\u5149\u306e\u30b9\u30ad\u30e3\u30f3\u306f\u3001\u30d7\u30ed\u30fc\u30d6\u306e\u30b9\u30dd\u30c3\u30c8\u306e\u30b5\u30a4\u30ba\uff08Feature Size\u3068\u547c\u3093\u3067\u3044\u307e\u3059\u304c\u3001\uff11\u7a2e\u985e\u306e\u30d7\u30ed\u30fc\u30d6\u304c\u5408\u6210\u3055\u308c\u3066\u3044\u308b\u9818\u57df\u30b5\u30a4\u30ba\uff09\u3088\u308a\u3082\u9ad8\u3044\u89e3\u50cf\u5ea6\u3067\u884c\u3063\u3066\u3044\u307e\u3059\u3002<br \/>\n\u8aad\u307f\u8fbc\u3093\u3060\u753b\u50cf\u60c5\u5831\u306f\u3001\u63a5\u7d9a\u3059\u308b\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u306b\u53d6\u308a\u8fbc\u307e\u308c\u3001\u51e6\u7406\u89e3\u6790\u3055\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_11263\" style=\"width: 819px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11263\" class=\"size-full wp-image-11263\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/14.png\" alt=\"\" width=\"809\" height=\"305\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/14.png 809w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/14-300x113.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/14-768x290.png 768w\" sizes=\"auto, (max-width: 809px) 100vw, 809px\" \/><p id=\"caption-attachment-11263\" class=\"wp-caption-text\">\u56f314. \u30b9\u30ad\u30e3\u30f3\u753b\u50cf\u3068\u753b\u50cf\u8a8d\u8b58\u3055\u308c\u51e6\u7406\u3055\u308c\u305f\u30c7\u30fc\u30bf<\/p><\/div>\n<p>.DAT \u30d5\u30a1\u30a4\u30eb\u306f\u30011 feature\u3042\u305f\u308a\uff5e50\u30d4\u30af\u30bb\u30eb\u306e\u753b\u50cf\u30d5\u30a1\u30a4\u30eb\u3067\u3059\u3002\u3053\u306e\u753b\u50cf\u304c\u81ea\u52d5\u8a8d\u8b58\u3001\u51e6\u7406\u3055\u308c .CEL\u30d5\u30a1\u30a4\u30eb\u304c\u751f\u6210\u3055\u308c\u307e\u3059\u30021 feature\u3042\u305f\u308a\uff11\u3064\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3092\u6301\u3064\u30c7\u30fc\u30bf\u3067\u3059\u3002\u3053\u306e\u5de5\u7a0b\u306b\u304a\u3044\u3066\u3082\u64cd\u4f5c\u8005\u304c\u4ecb\u5728\u305b\u305a\u3001\u5c02\u7528\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u306b\u5f93\u3063\u3066\u51e6\u7406\u3055\u308c\u307e\u3059\u306e\u3067\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044feature\u3054\u3068\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3001GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u5b9f\u9a13\u3092\u884c\u3046\u6a5f\u5668\u306e\u3054\u7d39\u4ecb\u3067\u3057\u305f\u3002<\/p>\n<p>\u5f53\u793e\u3067\u306f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u3084\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u306b\u95a2\u3059\u308b\u57fa\u790e\u7684\u306a\u5185\u5bb9\u304b\u3089\u5148\u7aef\u7814\u7a76\u307e\u3067\u3001\u5e45\u5e83\u3044\u5185\u5bb9\u3092\u30d6\u30ed\u30b0\u3067\u968f\u6642\u516c\u958b\u4e2d\u3067\u3059\u3002\u8a73\u3057\u304f\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tag\/%e3%83%9e%e3%82%a4%e3%82%af%e3%83%ad%e3%82%a2%e3%83%ac%e3%82%a4\/?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>GeneChip\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u88fd\u9020\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001\u5f53\u793e\u30db\u30fc\u30e0\u30da\u30fc\u30b8<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-education\/microarray-overview.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB#about\" target=\"_blank\" rel=\"noopener\">\u300c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u624b\u5f15\u304d &gt;&gt; \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u300d<\/a> \u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u95a2\u9023\u88fd\u54c1\u30da\u30fc\u30b8<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/00-0331?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip Hybridization Oven<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/00-0079?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip Fluidics Station 450<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-instruments\/genechip-scanner.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip Scanner 3000 7G<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/00-0213?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip Scanner 3000 7G System<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-instruments.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u6a5f\u5668<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-software.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">Microarray Analysis Software TAC Software<\/a><\/p>\n<p>\u95a2\u9023\u30d6\u30ed\u30b0\u8a18\u4e8b<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/points-you-should-know-when-using-contract-analysis-service-of-microarray\/?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u53d7\u8a17\u89e3\u6790\u3092\u5229\u7528\u3059\u308b\u969b\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30dd\u30a4\u30f3\u30c8<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/contractanalysis_ma_gsd_ts_1\/?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u53d7\u8a17\u89e3\u6790\u3092\u5229\u7528\u3059\u308b\u969b\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30dd\u30a4\u30f3\u30c8\u305d\u306e2<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/covid_ma_gsd_ts_1\/?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u65b0\u578b\u30b3\u30ed\u30ca\u30a6\u30a4\u30eb\u30b9\u306b\u3088\u308b\u91cd\u75c7\u5316\u30ea\u30b9\u30af\u3092\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3067\u77e5\u308b<\/a><\/p>\n<h2>[\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9]\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u7528\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2TAC<\/h2>\n<p>TAC\u3092\u4f7f\u3048\u3070\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u306f\u7c21\u5358\u3067\u3059\uff01\u305c\u3072\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-software\/affymetrix-transcriptome-analysis-console-software.html?cid=gsd_mic_lcs_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_og_s00_ma19_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3001\u67d3\u8272\u4f53\u30b3\u30d4\u30fc\u6570\u89e3\u6790\u3001SNP\u89e3\u6790\u306a\u3069\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308bDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304b\u3054\u5b58\u3058\u3067\u3057\u3087\u3046\u304b\u3002\u5b9f\u9a13\u81ea\u4f53\u306f\u53d7\u8a17\u89e3\u6790\u306b\u4f9d\u983c\u3057\u3066\u3044\u3066\u3001\u751f\u30c7\u30fc\u30bf\u3084\u89e3\u6790\u7d50\u679c\u3057\u304b\u898b\u305f\u3053\u3068\u304c\u306a\u3044\u3068\u3044\u3046\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u306e\u3067\u306f<\/p>\n","protected":false},"author":975,"featured_media":11252,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-11241","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3001\u67d3\u8272\u4f53\u30b3\u30d4\u30fc\u6570\u89e3\u6790\u3001SNP\u89e3\u6790\u306a\u3069\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308bDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304b\u3054\u5b58\u3058\u3067\u3057\u3087\u3046\u304b\u3002\u5b9f\u9a13\u81ea\u4f53\u306f\u53d7\u8a17\u89e3\u6790\u306b\u4f9d\u983c\u3057\u3066\u3044\u3066\u3001\u751f\u30c7\u30fc\u30bf\u3084\u89e3\u6790\u7d50\u679c\u3057\u304b\u898b\u305f\u3053\u3068\u304c\u306a\u3044\u3068\u3044\u3046\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u306e\u3067\u306f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-11T00:00:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-05T06:05:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1172\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"16\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f\",\"datePublished\":\"2022-03-11T00:00:24+00:00\",\"dateModified\":\"2022-04-05T06:05:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/\"},\"wordCount\":250,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/03\\\/89401034a7a01c0a62e3ce114041fc12.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/\",\"name\":\"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/03\\\/89401034a7a01c0a62e3ce114041fc12.jpg\",\"datePublished\":\"2022-03-11T00:00:24+00:00\",\"dateModified\":\"2022-04-05T06:05:39+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/03\\\/89401034a7a01c0a62e3ce114041fc12.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/03\\\/89401034a7a01c0a62e3ce114041fc12.jpg\",\"width\":1172,\"height\":720,\"caption\":\"\u56f310. GeneChip Fluidics Station 450\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dna_microarray_ma_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f","og_description":"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3001\u67d3\u8272\u4f53\u30b3\u30d4\u30fc\u6570\u89e3\u6790\u3001SNP\u89e3\u6790\u306a\u3069\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308bDNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304b\u3054\u5b58\u3058\u3067\u3057\u3087\u3046\u304b\u3002\u5b9f\u9a13\u81ea\u4f53\u306f\u53d7\u8a17\u89e3\u6790\u306b\u4f9d\u983c\u3057\u3066\u3044\u3066\u3001\u751f\u30c7\u30fc\u30bf\u3084\u89e3\u6790\u7d50\u679c\u3057\u304b\u898b\u305f\u3053\u3068\u304c\u306a\u3044\u3068\u3044\u3046\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u306e\u3067\u306f","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-03-11T00:00:24+00:00","article_modified_time":"2022-04-05T06:05:39+00:00","og_image":[{"width":1172,"height":720,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"16\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f","datePublished":"2022-03-11T00:00:24+00:00","dateModified":"2022-04-05T06:05:39+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/"},"wordCount":250,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/","name":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","datePublished":"2022-03-11T00:00:24+00:00","dateModified":"2022-04-05T06:05:39+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","width":1172,"height":720,"caption":"\u56f310. GeneChip Fluidics Station 450"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dna_microarray_ma_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"DNA\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3063\u3066\u898b\u305f\u3053\u3068\u3042\u308a\u307e\u3059\u304b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12-1024x629.jpg",760,467,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":11241,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":11241,"position":1},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":11241,"position":2},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":11241,"position":3},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":11241,"position":4},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":11241,"position":5},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/89401034a7a01c0a62e3ce114041fc12.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=11241"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11241\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/11252"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=11241"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=11241"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=11241"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=11241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}