{"id":11327,"date":"2022-04-01T10:44:58","date_gmt":"2022-04-01T01:44:58","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=11327"},"modified":"2022-04-04T14:17:13","modified_gmt":"2022-04-04T05:17:13","slug":"rna_analysis_application_ma_gsd_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/","title":{"rendered":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09"},"content":{"rendered":"<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u3001\u65e2\u306b20\u5e74\u4ee5\u4e0a\u304c\u7d4c\u904e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u89e3\u6790\u6280\u8853\u306f\u73fe\u5728\u3067\u3082\u9032\u5316\u3092\u7d9a\u3051\u3001\u533b\u5b66\u5206\u91ce\u3060\u3051\u3067\u306a\u304f\u3001\u751f\u547d\u73fe\u8c61\u306b\u95a2\u9023\u3057\u305f\u57fa\u790e\u7814\u7a76\u5206\u91ce\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u3053\u306e\u89e3\u6790\u306f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306b\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u304c\u591a\u304f\u30011\u56de\u306e\u5b9f\u9a13\u3067\u7279\u5b9a\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u91cf\u306e\u5897\u6e1b\u3092\u6e2c\u5b9a\u3059\u308bNorthern blot\u6cd5\u306b\u6bd4\u3079\u3066\u3001\u6570\u4e07\u4ee5\u4e0a\u306b\u53ca\u3076\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u91cf\u5897\u6e1b\u3092\u7db2\u7f85\u7684\u306b\u6e2c\u5b9a\u3059\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u30c4\u30fc\u30eb\u3068\u3057\u3066\u306e\u4f7f\u7528\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u305d\u3053\u3067\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306b\u304a\u3044\u3066\u3001\u3069\u306e\u3088\u3046\u306a\u89e3\u6790\u304c\u884c\u308f\u308c\u3066\u304d\u305f\u304b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>3\u2019 IVT Array\u306b\u3088\u308b\u89e3\u6790<\/h2>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u304c\u767b\u5834\u3057\u305f\u5f53\u6642\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u30a2\u30ec\u30a4\u3092\u3001\u3053\u3053\u3067\u306f3\u2019 IVT Array\u3068\u7dcf\u79f0\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30aa\u30ea\u30b4dT\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u5229\u7528\u3057\u305f\u9006\u8ee2\u5199\u53cd\u5fdc\u3068In Vitro Transcription\uff08IVT\uff09\u30a2\u30c3\u30bb\u30a4\u3092\u30d9\u30fc\u30b9\u306b\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u65b9\u6cd5\u3067\u3001\u4e0b\u56f3\u306e\u3088\u3046\u306b\u30a2\u30ec\u30a4\u306b\u642d\u8f09\u3055\u308c\u308b\u5404\u907a\u4f1d\u5b50\u306b\u5bfe\u5fdc\u3057\u305f\u30d7\u30ed\u30fc\u30d6\u304c\u3001mRNA\u306e3\u2019\u672b\u7aef\u5074\u3067\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u306b\u8d77\u56e0\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-11329\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image1-1-1024x165.jpg\" alt=\"\" width=\"760\" height=\"122\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image1-1-1024x165.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image1-1-300x48.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image1-1-768x123.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image1-1.jpg 1207w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<h3>3\u2019 IVT Array\u306e\u4f7f\u7528\u4f8b<\/h3>\n<p>\u3053\u306e3\u2019 IVT Array\u3092\u4f7f\u3063\u305f\u89e3\u6790\u3068\u3057\u3066\u3001\u75be\u60a3\u3068\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u5909\u52d5\u306e\u95a2\u9023\u6027\u306b\u3064\u3044\u3066\u306e\u7814\u7a76\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u305d\u306e\u4e2d\u306b\u306f\u304c\u3093\u3092\u5206\u985e\u3057\u305f\u308a\u3001\u3042\u308b\u3044\u306f\u304c\u3093\u60a3\u8005\u306e\u4e88\u5f8c\u3092\u4e88\u6e2c\u3057\u305f\u308a\u3059\u308b\u305f\u3081\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u691c\u7d22\u3092\u884c\u3046\u3068\u3044\u3063\u305f\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u6025\u6027\u30ea\u30f3\u30d1\u82bd\u7403\u6027\u767d\u8840\u75c5\uff08ALL\uff09\u3068\u6025\u6027\u9aa8\u9ac4\u6027\u767d\u8840\u75c5\uff08AML\uff09\u306b\u306f\u3001\u305d\u308c\u305e\u308c\u306b\u9069\u5207\u306a\u6cbb\u7642\u6cd5\u304c\u3042\u308b\u305f\u3081\u3001\u5206\u985e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u306e\u5206\u985e\u306b\u306f\u3001\u816b\u760d\u306e\u5f62\u614b\u3001\u7d44\u7e54\u5316\u5b66\u3001\u514d\u75ab\u8868\u73fe\u578b\u691c\u67fb\u3001\u304a\u3088\u3073\u7d30\u80de\u907a\u4f1d\u5b66\u7684\u5206\u6790\u3068\u3044\u3063\u305f\u3001\u305d\u308c\u305e\u308c\u306b\u5c02\u9580\u7684\u306a\u89e3\u91c8\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002\u305d\u3053\u3067Golub\u3089\u306f\u3001ALL\u3068AML\u306b\u3064\u3044\u3066\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306b\u57fa\u3065\u304f\u5206\u5b50\u5206\u985e\u306e\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u5831\u544a\u3057\u3066\u3044\u307e\u3059<sup>1)<\/sup>\u3002\u521d\u3081\u306b\u65e2\u77e5\u306eALL\u3068AML\u691c\u4f53\u3092\u4f7f\u3063\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u30d1\u30bf\u30fc\u30f3\u3092\u78ba\u8a8d\u3057\u3001\u7d041,100\u500b\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u30d1\u30bf\u30fc\u30f3\u304c\u76f8\u95a2\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u6b21\u306b\u5225\u306e\u691c\u4f53\u3092\u4f7f\u3063\u3066\u3001\u305d\u306e\u78ba\u8a8d\u3092\u3059\u308b\u3068\u5171\u306bALL\u3068AML\u3092\u533a\u5225\u3059\u308b\u306e\u306b\u76f8\u95a2\u6027\u304c\u9ad8\u304450\u907a\u4f1d\u5b50\u3092\u9078\u629e\u3057\u307e\u3057\u305f\u3002\u305d\u3057\u3066\u3001\u9078\u629e\u3057\u305f\u907a\u4f1d\u5b50\u306e\u59a5\u5f53\u6027\u3092\u691c\u8a3c\u3059\u308b\u305f\u3081\u306b\u65b0\u305f\u306a\u691c\u4f53\u3067\u6709\u52b9\u6027\u3092\u78ba\u8a8d\u3057\u3001\u3053\u306e\u624b\u6cd5\u3092\u81e8\u5e8a\u7684\u306b\u5b9f\u65bd\u3059\u308b\u305f\u3081\u306b\u306f\u6e96\u5099\u3059\u308b\u691c\u4f53\u306e\u6a19\u6e96\u5316\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u3082\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u307e\u305f\u3001Wang\u3089\u306f\u3001\u30ea\u30f3\u30d1\u7bc0\u8ee2\u79fb\u9670\u6027\u306e\u539f\u767a\u6027\u4e73\u304c\u3093\u60a3\u8005\u306e\u9060\u9694\u8ee2\u79fb\u3092\u4e88\u6e2c\u3059\u308b\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u306e\u63a2\u7d22\u3092\u884c\u3063\u3066\u3044\u307e\u3059<sup>2)<\/sup>\u3002\u521d\u3081\u306b115\u4eba\u306e\u691c\u4f53\u3092\u4f7f\u3063\u3066\u907a\u4f1d\u5b50\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u884c\u3044\u300176\u500b\u306e\u907a\u4f1d\u5b50\u3092\u7279\u5b9a\u3057\u307e\u3057\u305f\u3002\u6b21\u306b\u5225\u306e171\u4eba\u306e\u691c\u4f53\u3092\u4f7f\u3063\u3066\u3001\u305d\u306e\u78ba\u8a8d\u3092\u884c\u3063\u305f\u7d50\u679c\u3001\u3053\u306e\u907a\u4f1d\u5b50\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306f5\u5e74\u4ee5\u5185\u306b\u9060\u9694\u8ee2\u79fb\u3092\u767a\u75c7\u3057\u305f\u60a3\u8005\u3092\u7279\u5b9a\u3059\u308b\u4e0a\u3067\u6709\u76ca\u3067\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u305d\u3057\u3066Foekens\u3089\u306f\u3001\u8907\u6570\u65bd\u8a2d\u306e\u30ea\u30f3\u30d1\u7bc0\u9670\u6027\u4e73\u304c\u3093\u60a3\u8005\u306e\u691c\u4f53\u306b\u5bfe\u3057\u3066\u3001\u3053\u306e76\u907a\u4f1d\u5b50\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306e\u691c\u8a3c\u3092\u884c\u3063\u3066\u9060\u9694\u8ee2\u79fb\u306e\u3042\u308b\u60a3\u8005\u3092\u7279\u5b9a\u3059\u308b\u306e\u306b\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3001\u88dc\u52a9\u5168\u8eab\u7642\u6cd5\u3092\u56de\u907f\u3067\u304d\u308b\u60a3\u8005\u3092\u898b\u5206\u3051\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059<sup>3)<\/sup>\u3002<br \/>\n\u4e00\u65b9\u3001\u3053\u306e\u3088\u3046\u306a\u533b\u5b66\u306b\u95a2\u4fc2\u3057\u305f\u5206\u91ce\u3060\u3051\u3067\u306a\u304f\u3001\u751f\u547d\u73fe\u8c61\u306b\u95a2\u3059\u308b\u7814\u7a76\u306b\u3082\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u4e00\u822c\u7684\u306b\u306f\u4f53\u5185\u6642\u8a08\u3068\u3082\u8a00\u308f\u308c\u308b\u6982\u65e5\u30ea\u30ba\u30e0\u306f\u591a\u304f\u306e\u751f\u7269\u306b\u5b58\u5728\u3057\u3001\u3055\u307e\u3056\u307e\u306a\u751f\u7406\u73fe\u8c61\u306b\u95a2\u308f\u308b\u907a\u4f1d\u5b50\u304c\u5468\u671f\u6027\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u30b2\u30ce\u30e0\u5168\u4f53\u304c\u6982\u65e5\u30ea\u30ba\u30e0\u306b\u3088\u3063\u3066\u3069\u306e\u3088\u3046\u306b\u8abf\u6574\u3055\u308c\u3066\u3044\u308b\u306e\u304b\u3092\u628a\u63e1\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002Ueda\u3089\u306f\u3001\u30b7\u30e7\u30a6\u30b8\u30e7\u30a6\u30d0\u30a8\u3092\u4f7f\u3063\u3066\u5468\u671f\u7684\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u7db2\u7f85\u7684\u89e3\u6790\u3092\u884c\u3063\u3066\u3044\u307e\u3059<sup>4)<\/sup>\u3002\u30b7\u30e7\u30a6\u30b8\u30e7\u30a6\u30d0\u30a8\u982d\u90e8\u30b5\u30f3\u30d7\u30eb\u3067\u89e3\u6790\u3092\u884c\u3063\u305f\u7d50\u679c\u3001\u660e\u6697\u6761\u4ef6\u4e0b\u3067712\u500b\u304c\u5468\u671f\u7684\u306b\u767a\u73fe\u5909\u52d5\u3057\u3066\u304a\u308a\u3001\u305d\u306e\u3046\u3061\u306e115\u907a\u4f1d\u5b50\u306f\u6052\u6697\u6761\u4ef6\u4e0b\u3067\u3082\u5468\u671f\u7684\u306b\u767a\u73fe\u5909\u52d5\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u305d\u3057\u3066\u3001\u591a\u69d8\u306a\u6a5f\u80fd\u306b\u95a2\u4e0e\u3059\u308b\u591a\u304f\u306e\u907a\u4f1d\u5b50\u304c\u6982\u65e5\u30ea\u30ba\u30e0\u306e\u5236\u5fa1\u4e0b\u3067\u5468\u671f\u7684\u306b\u767a\u73fe\u3057\u3066\u3044\u3066\u3001\u67d3\u8272\u4f53\u4e0a\u3067\u30af\u30e9\u30b9\u30bf\u30fc\u304c\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u6982\u65e5\u30ea\u30ba\u30e0\u4e0b\u3067\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u8907\u96d1\u3055\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u306e\u3088\u3046\u306b1\u56de\u306e\u5b9f\u9a13\u3067\u7db2\u7f85\u7684\u306b\u907a\u4f1d\u5b50\u767a\u73fe\u30d1\u30bf\u30fc\u30f3\u306e\u89e3\u6790\u304c\u53ef\u80fd\u306a\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u3053\u308c\u307e\u3067\u306e\u7814\u7a76\u3067\u5f97\u3089\u308c\u305f\u591a\u6570\u306e\u30c7\u30fc\u30bf\u306f\u3001\u7c73\u56fdNational Center for Biotechnology Information\uff08NCBI\uff09\u306eGene Expression Omnibus\uff08GEO\uff09<sup>5)<\/sup>\u3084\u3001\u82f1\u56fdEuropean Bioinformatics Institute\uff08EBI\uff09\u306eArrayExpress<sup>6)<\/sup>\u306e\u3088\u3046\u306a\u516c\u5171\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306b\u767b\u9332\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u516c\u5171\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306b\u767b\u9332\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u304b\u3089\u8a72\u5f53\u3059\u308b\u30c7\u30fc\u30bf\u3092\u5229\u7528\u3057\u3066\u4e00\u6b21\u7684\u306a\u89e3\u6790\u3092\u884c\u3044\u3001\u5f97\u3089\u308c\u305f\u7d50\u679c\u306b\u3064\u3044\u3066\u8ffd\u52a0\u306e\u691c\u8a3c\u5b9f\u9a13\u3059\u308b\u3053\u3068\u3067\u3001\u75be\u60a3\u306e\u4e88\u5f8c\u4e88\u6e2c\u3059\u308b\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3092\u63a2\u7d22\u3057\u305f\u3088\u3046\u306a\u4f8b\u3082\u3042\u308a\u307e\u3059<sup>7)<\/sup>\u3002<\/p>\n<h2>Whole Transcriptome Array\uff08WT Array\uff09\u306b\u3088\u308b\u89e3\u6790<\/h2>\n<p>\u30d2\u30c8\u30b2\u30ce\u30e0\u89e3\u6790\u304c\u9032\u3093\u3067\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u306e\u7814\u7a76\u304c\u767a\u5c55\u3057\u3066\u304f\u308b\u3068\u3001\u307b\u3068\u3093\u3069\u306e\u907a\u4f1d\u5b50\u306b\u304a\u3044\u3066\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u304c\u8d77\u3053\u3063\u3066\u3044\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u304b\u3089\u306a\u308b\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u304c\u5b58\u5728\u3059\u308b\u3053\u3068\u304c\u5206\u304b\u3063\u3066\u304d\u307e\u3057\u305f\u3002\u305d\u306e\u305f\u3081\u3001\u4f8b\u3048\u3070\u907a\u4f1d\u5b50\u306e3\u2019\u672b\u7aef\u90e8\u4f4d\u3092\u6301\u305f\u306a\u3044\u30d1\u30bf\u30fc\u30f3\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u304c\u767a\u73fe\u3057\u3066\u3044\u305f\u5834\u5408\u306f\u3001\u3053\u308c\u307e\u3067\u306e3\u2019\u672b\u7aef\u5074\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3057\u305f\u30d7\u30ed\u30fc\u30d6\u30c7\u30b6\u30a4\u30f3\u3067\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u3067\u306f\u691c\u51fa\u304c\u56f0\u96e3\u3068\u306a\u308a\u307e\u3059\u3002\u3042\u308b\u3044\u306f\u3001Bcl-x\u907a\u4f1d\u5b50\u306e\u3088\u3046\u306b\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u3063\u3066\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u3092\u963b\u5bb3\u3059\u308bBcl-xL\u3068\u4fc3\u9032\u3059\u308bBcl-xS\u304c\u5f62\u6210\u3055\u308c\u30011\u3064\u306e\u907a\u4f1d\u5b50\u304b\u3089\u6b63\u8ca0\u306e\u5236\u5fa1\u306b\u95a2\u4fc2\u3059\u308b\u3001\u76f8\u53cd\u3059\u308b\u56e0\u5b50\u304c\u4f5c\u3089\u308c\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059<sup>8)<\/sup>\u3002\u307e\u305f\u3001\u907a\u4f1d\u5b50\u306e\u7a81\u7136\u5909\u7570\u304c\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u7570\u5e38\u3092\u8d77\u3053\u3057\u3001\u305d\u306e\u3053\u3068\u304c\u91cd\u7be4\u306a\u75be\u60a3\u306b\u3064\u306a\u304c\u3063\u3066\u3044\u308b\u3068\u306e\u5831\u544a\u3082\u3042\u308a\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-11330\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image2-1.jpg\" alt=\"\" width=\"941\" height=\"684\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image2-1.jpg 941w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image2-1-300x218.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image2-1-768x558.jpg 768w\" sizes=\"auto, (max-width: 941px) 100vw, 941px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-11331\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Table1-1024x664.jpg\" alt=\"\" width=\"760\" height=\"493\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Table1-1024x664.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Table1-300x194.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Table1-768x498.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Table1.jpg 1376w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u3055\u3089\u306b\u3001\u30b2\u30ce\u30e0\u4e0a\u306b\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3057\u3066\u3044\u306a\u3044\u9577\u9396\u306enon-coding RNA\uff08lncRNA\uff09\u304c\u591a\u304f\u5b58\u5728\u3057\u3066\u3044\u308b\u3068\u3044\u3046\u3053\u3068\u3082\u660e\u3089\u304b\u306b\u306a\u308a\u3001\u3053\u308c\u3089\u304c\u3055\u307e\u3056\u307e\u306a\u75be\u60a3\u3068\u95a2\u9023\u3057\u3066\u3044\u308b\u3068\u3044\u3046\u5831\u544a\u3082\u3067\u3066\u304d\u3066\u3044\u307e\u3059\u3002<br \/>\n\u305d\u3053\u3067\u3001\u3059\u3079\u3066\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3092\u691c\u51fa\u3059\u308b\u76ee\u7684\u3067\u3001\u30d7\u30ed\u30fc\u30d6\u30c7\u30b6\u30a4\u30f3\u9818\u57df\u30923\u2019\u672b\u7aef\u5074\u3060\u3051\u3067\u306a\u304f\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u5168\u9818\u57df\u3092\u5bfe\u8c61\u3068\u3057\u305fWhole Transcript Array\uff08WT\u30a2\u30ec\u30a4\uff09\u304c\u767b\u5834\u3057\u307e\u3057\u305f\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-11332\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image3-1024x420.jpg\" alt=\"\" width=\"760\" height=\"312\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image3-1024x420.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image3-300x123.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image3-768x315.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/03\/Image3.jpg 1253w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<h3>\u7814\u7a76\u76ee\u7684\u306b\u5408\u308f\u305b\u305fClariom S Array\u3068Clariom D Array\u306e\u7279\u5fb4\u3068\u4f7f\u3044\u5206\u3051<\/h3>\n<p>\u73fe\u5728\u3001\u30d2\u30c8\u3001\u30de\u30a6\u30b9\u3001\u30e9\u30c3\u30c8\u306e3\u751f\u7269\u7a2e\u306eWT Array\u306f\u3001Applied Biosystems\u2122 Clariom\u2122 S Array\u3068Clariom\u2122 D Array\u306e2\u7a2e\u985e\u304c\u3042\u308a\u307e\u3059\u3002Clariom S Array\u3067\u306f\u3001\u660e\u78ba\u306a\u30a2\u30ce\u30c6\u30fc\u30b7\u30e7\u30f3\u60c5\u5831\u3092\u6301\u3063\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3057\u3066\u3044\u308b\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u306e\u89e3\u6790\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001Clariom D Array\u3067\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b3\u30fc\u30c9\u3057\u3066\u3044\u308b\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3060\u3051\u3067\u306a\u304f\u3001lncRNA\u306b\u5bfe\u3059\u308b\u30d7\u30ed\u30fc\u30d6\u3082\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u3069\u3061\u3089\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u306b\u5bfe\u3057\u3066\u3082\u767a\u73fe\u89e3\u6790\u304c\u53ef\u80fd\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u30a8\u30af\u30bd\u30f3\u90e8\u5206\u3060\u3051\u3067\u306a\u304f\u3001\u30a8\u30af\u30bd\u30f3\u9593\u306e\u30b8\u30e3\u30f3\u30af\u30b7\u30e7\u30f3\u90e8\u5206\u306b\u5bfe\u5fdc\u3057\u305f\u30d7\u30ed\u30fc\u30d6\u3082\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u7cbe\u5ea6\u306e\u9ad8\u3044\u30a8\u30af\u30bd\u30f3\u30ec\u30d9\u30eb\u3067\u306e\u89e3\u6790\u3082\u53ef\u80fd\u3067\u3059\u3002\u4ee5\u4e0a\u306e\u3053\u3068\u304b\u3089\u3001\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u3067\u306e\u767a\u73fe\u89e3\u6790\u304c\u76ee\u7684\u306e\u5834\u5408\u306fClariom S Array\u3001\u907a\u4f1d\u5b50\u30ec\u30d9\u30eb\u3067\u306e\u767a\u73fe\u89e3\u6790\u3060\u3051\u3067\u306a\u304f\u30a8\u30af\u30bd\u30f3\u30ec\u30d9\u30eb\u3067\u306e\u767a\u73fe\u89e3\u6790\u3084lncRNA\u306e\u767a\u73fe\u89e3\u6790\u304c\u76ee\u7684\u306e\u5834\u5408\u306fClariom D Array\u3068\u3044\u3046\u3088\u3046\u306b\u3001\u7814\u7a76\u76ee\u7684\u306b\u5408\u308f\u305b\u3066\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u5229\u7528\u3059\u308b\u5f62\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n\u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u884c\u3046\u5834\u5408\u3001\u73fe\u5728\u306f\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u306b\u3088\u308bRNA-Seq\u3067\u3082\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u304c\u3001Clariom S Array\u3067\u306f1000\u4e07\u304b\u30891\u5104\u30ea\u30fc\u30c9\u306eRNA-Seq\u306b\u76f8\u5f53\u3059\u308b\u89e3\u50cf\u5ea6\u306e\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001Clariom D Array\u3067\u306f7\u5104\u30ea\u30fc\u30c9\u306eRNA-Seq\u306b\u76f8\u5f53\u3059\u308b\u9ad8\u89e3\u50cf\u5ea6\u306e\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u4eca\u5f8c\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u3067\u306e\u4e3b\u6d41\u306b\u306a\u308b\u3053\u3068\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<h3>Clariom S Array\u306e\u4f7f\u7528\u4f8b<\/h3>\n<p>Clariom S Array\u306e\u4f7f\u7528\u4f8b\u3068\u3057\u3066\u306f\u3001COVID-19\u306b\u95a2\u9023\u3057\u305f\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u63a2\u7d22\u3084\u6cbb\u7642\u6cd5\u3078\u306e\u77e5\u898b\u306b\u3064\u3044\u3066\u306e\u5831\u544a\u304c\u3042\u308a\u307e\u3059\u3002SARS\u2011CoV\u20112\u306b\u611f\u67d3\u3057\u305f\u60a3\u8005\u9593\u3067\u91cd\u75c7\u5ea6\u306b\u9055\u3044\u304c\u3042\u3063\u305f\u308a\u3001\u4eba\u306b\u3088\u3063\u3066\u306f\u7121\u75c7\u72b6\u3067\u3042\u3063\u305f\u308a\u3068\u3055\u307e\u3056\u307e\u3067\u3059\u3002Masood\u3089\u306f\u3001\u3053\u308c\u3089\u306e\u60a3\u8005\u304b\u3089\u306e\u691c\u4f53\u306b\u3064\u3044\u3066Applied Biosystems\u2122 Clariom\u2122 S Array, human\u3067\u89e3\u6790\u3092\u884c\u3044\u3001\u7121\u75c7\u72b6\u691c\u4f53\u3067\u306f\u75be\u60a3\u75c7\u5019\u691c\u4f53\u3068\u6bd4\u8f03\u3059\u308b\u3068\u8907\u6570\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u8a98\u5c0e\u6027\u907a\u4f1d\u5b50\uff08ISG\uff09\u304c\u6709\u610f\u306b\u767a\u73fe\u5897\u52a0\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f<sup>9)<\/sup>\u3002\u305d\u306e\u305f\u3081\u3001\u7121\u75c7\u72b6\u306e\u5834\u5408\u306eSARS\u2011CoV\u20112\u611f\u67d3\u5f8c\u521d\u671f\u3067\u306f\u3001ISG\u306b\u3088\u3063\u3066\u52b9\u679c\u7684\u306b\u5236\u5fa1\u3055\u308c\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u3053\u3068\u304b\u3089\u3001COVID-19\u306e\u521d\u671f\u6bb5\u968e\u3067\u306fISG\u3092\u6d3b\u6027\u5316\u3059\u308bI\u5f62\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30ed\u30f3\u306b\u3088\u308b\u6cbb\u7642\u306f\u3001\u75be\u60a3\u306e\u9032\u884c\u3092\u6291\u5236\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n<h3>Clariom D Array\u306e\u4f7f\u7528\u4f8b<\/h3>\n<p>\u4e00\u65b9\u3001Clariom D Array\u306e\u4f7f\u7528\u4f8b\u3068\u3057\u3066\u306f\u3001\u816b\u760d\u7d30\u80de\u3067\u306f\u7570\u5e38\u306a\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308a\u3001\u672c\u6765\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3068\u306f\u7570\u306a\u3063\u305f\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u304c\u767a\u73fe\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002Taniguchi-Ponciano\u3089\u306f\u3001Applied Biosystems\u2122 Clariom\u2122 D Array, human\u3092\u4f7f\u3063\u30662\u7a2e\u985e\u306e\u7d30\u80de\u7cfb\u7d71\uff08POU1F1\u3001NR5A1\uff09\u306b\u7531\u6765\u3059\u308b\u4e0b\u5782\u4f53\u817a\u816b\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u89e3\u6790\u3092\u884c\u3044\u307e\u3057\u305f<sup>10)<\/sup>\u3002\u305d\u306e\u7d50\u679c\u3001POU1F1\u7d30\u80de\u7cfb\u7d71\u7531\u6765\u306e\u4e0b\u5782\u4f53\u816b\u760d\u3067\u306fTHY1\u3001BMPER\u3001GRIA3\u306a\u3069\u306e\u907a\u4f1d\u5b50\u3067\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u304c\u751f\u6210\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001NR5A1\u7d30\u80de\u7cfb\u7d71\u7531\u6765\u306e\u4e0b\u5782\u4f53\u816b\u760d\u3067\u306fCDK18\u3001SEMA7A\u3001PTGS2\u3001KCNA3\u306a\u3069\u306e\u907a\u4f1d\u5b50\u306e\u9078\u629e\u7684\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u306b\u3088\u308b\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u304c\u751f\u6210\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u4e0b\u5782\u4f53\u816b\u760d\u3092\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u95a2\u9023\u907a\u4f1d\u5b50\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306b\u3088\u3063\u3066\u5206\u985e\u3067\u304d\u308b\u3053\u3068\u3082\u63a8\u5bdf\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u3053\u3068\u304b\u3089\u3001\u30a2\u30a4\u30bd\u30d5\u30a9\u30fc\u30e0\u3084\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u95a2\u9023\u907a\u4f1d\u5b50\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306f\u3001\u816b\u760d\u306e\u30b5\u30d6\u30bf\u30a4\u30d7\u3092\u7279\u5fb4\u3065\u3051\u3001\u5206\u5b50\u30de\u30fc\u30ab\u30fc\u304a\u3088\u3073\u5206\u5b50\u7642\u6cd5\u306e\u6a19\u7684\u3068\u3057\u3066\u4f7f\u7528\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3068\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u307e\u305f\u3001lncRNA\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u3057\u305f\u7814\u7a76\u306b\u3082Clariom D Array\u306f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u52a0\u9f62\u306b\u4f34\u3063\u3066\u8d77\u3053\u308b\u55c5\u899a\u6a5f\u80fd\u306e\u4f4e\u4e0b\u306f\u9ad8\u9f62\u8005\u306e\u751f\u6d3b\u306e\u8cea\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u3001\u6f5c\u5728\u7684\u306a\u795e\u7d4c\u5909\u6027\u75be\u60a3\u306e\u65e9\u671f\u81e8\u5e8a\u75c7\u72b6\u306e1\u3064\u3068\u3057\u3066\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u3001Wang\u3089\u306f\u3001\u5e74\u9f62\u306e\u7570\u306a\u308b3\u7fa4\u306e\u30de\u30a6\u30b9\u3092\u30e2\u30c7\u30eb\u306b\u3057\u3066Applied Biosystems\u2122 Clariom\u2122 D Array, mouse\u3092\u4f7f\u3044\u3001\u55c5\u899a\u969c\u5bb3\u306e\u6f5c\u5728\u7684\u5f79\u5272\u306b\u95a2\u308f\u308b\u56e0\u5b50\u3092\u691c\u7d22\u3057\u307e\u3057\u305f<sup>11)<\/sup>\u3002\u305d\u306e\u7d50\u679c\u3001\u82e5\u3044\u6210\u4f53\u30de\u30a6\u30b9\u3068\u8001\u9f62\u30de\u30a6\u30b9\u3067\u306f\u55c5\u899a\u60c5\u5831\u4f1d\u9054\u3067\u4e2d\u5fc3\u7684\u306a\u5f79\u5272\u3092\u6301\u3063\u3066\u3044\u308b\u55c5\u7403\u306b\u304a\u3044\u3066\u3001112\u500b\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u30b3\u30fc\u30c7\u30a3\u30f3\u30b0\u907a\u4f1d\u5b50\uff08PCG\uff09\u306884\u500b\u306elncRNA\u304c\u767a\u73fe\u5909\u52d5\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306ePCG\u306f\u3001\u30b7\u30b0\u30ca\u30eb\u4f1d\u9054\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u8abf\u7bc0\u3001\u7d30\u80de\u5fae\u5c0f\u74b0\u5883\u306b\u95a2\u9023\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u307e\u305f\u30012\u3064\u306elncRNA\uff08NONMMUT004524\u3001NONMMUT000384\uff09\u304c\u8001\u9f62\u30de\u30a6\u30b9\u306e\u55c5\u7403\u306b\u304a\u3051\u308b\u795e\u7d4c\u6d3b\u6027\u30ea\u30ac\u30f3\u30c9-\u53d7\u5bb9\u4f53\u76f8\u4e92\u4f5c\u7528\u7d4c\u8def\u3068\u6709\u610f\u306b\u95a2\u9023\u3057\u3066\u304a\u308a\u3001\u6f5c\u5728\u7684\u306a\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>miRNA Array\u306b\u3088\u308b\u89e3\u6790<\/h2>\n<p>miRNA\u306f20\uff5e25\u5869\u57fa\u7a0b\u5ea6\u306e\u9577\u3055\u304b\u3089\u306a\u308b\u4e00\u672c\u9396RNA\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u751f\u7269\u306b\u5b58\u5728\u3059\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u306f\u7ffb\u8a33\u3055\u308c\u306a\u3044non-coding RNA\u306e1\u3064\u3067\u3059\u3002\u3053\u306e\u9396\u9577\u306e\u77ed\u3044RNA\u5206\u5b50\u306f\u3001\u3055\u307e\u3056\u307e\u306amRNA\u306e\u767a\u73fe\u3092\u8abf\u7bc0\u3057\u3001\u5206\u5316\u3001\u7d30\u80de\u5897\u6b96\u3001\u30a2\u30dd\u30c8\u30fc\u30b7\u30b9\u306a\u3069\u3001\u751f\u7269\u306b\u3068\u3063\u3066\u6b20\u304b\u305b\u306a\u3044\u751f\u547d\u73fe\u8c61\u306b\u95a2\u308f\u3063\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059<sup>12), 13)<\/sup>\u3002\u307e\u305f\u3001\u304c\u3093\u306a\u3069\u306e\u75be\u60a3\u306b\u304a\u3044\u3066miRNA\u306e\u767a\u73fe\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u304c\u56fa\u6709\u306e\u30d1\u30bf\u30fc\u30f3\u3092\u793a\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u3001miRNA\u3092\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u3057\u3066\u691c\u8a0e\u3059\u308b\u7814\u7a76\u304c\u5897\u3048\u3066\u304d\u3066\u3044\u307e\u3059<sup>14), 15)<\/sup>\u3002<\/p>\n<h3>GeneChip miRNA Array\u306e\u4f7f\u7528\u4f8b<\/h3>\n<p>Applied Biosystems\u2122 GeneChip\u2122 miRNA Array\u306e\u4f7f\u7528\u4f8b\u3068\u3057\u3066\u3001Yong\u3089\u306f\u3001\u7d44\u7e54\u3068\u8840\u6db2\u306e2\u3064\u306e\u691c\u4f53\u3092\u4f7f\u3063\u3066\u7d50\u8178\u76f4\u8178\u304c\u3093\uff08CRC\uff09\u306e\u65e9\u671f\u767a\u898b\u306e\u305f\u3081\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u63a2\u7d22\u3092\u884c\u3063\u3066\u3044\u307e\u3059<sup>16)<\/sup>\u3002\u305d\u306e\u7d50\u679c\u3001\u4e21\u30bf\u30a4\u30d7\u306e\u691c\u4f53\u306b\u5171\u901a\u3057\u30667\u7a2e\u985e\u306emiRNA\uff08miR-150\u3001miR-193a-3p\u3001miR-23a\u3001miR-23b\u3001miR-338-5p\u3001miR-342-3p\u3001miR-483-3p\uff09\u306b\u767a\u73fe\u5909\u52d5\u304c\u898b\u3089\u308c\u3001\u3055\u3089\u306b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u306e\u691c\u8a3c\u3067\u30013\u7a2e\u985e\u306emiRNA\uff08miR-193a-3p\u3001miR-23a\u3001miR-338-5p\uff09\u306f\u3001\u7d44\u7e54\u304a\u3088\u3073\u8840\u4e2d\u30ec\u30d9\u30eb\u3067\u6709\u610f\u306b\u6b63\u306e\u76f8\u95a2\u304c\u3042\u308b\u3053\u3068\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306emiRNA\u306e\u767a\u73fe\u5897\u52a0\u306f\u3001\u304c\u3093\u304c\u3088\u308a\u9032\u884c\u3057\u305f\u6bb5\u968e\u3067\u3082\u691c\u51fa\u3055\u308c\u3066\u304a\u308a\u3001CRC\u65e9\u671f\u767a\u898b\u306e\u305f\u3081\u306b\u30ea\u30ad\u30c3\u30c9\u30d0\u30a4\u30aa\u30d7\u30b7\u30fc\u3068\u3057\u3066\u306e\u8840\u6db2\u691c\u4f53\u304b\u3089\u306e\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u306a\u308b\u53ef\u80fd\u6027\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u307e\u305f\u3001Kumar\u3089\u306f\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u60a3\u8005\u3068\u8efd\u5ea6\u8a8d\u77e5\u969c\u5bb3\u60a3\u8005\u3068\u5065\u5e38\u4eba\u304b\u3089\u306e\u8840\u6e05\u691c\u4f53\u3092\u7528\u3044\u3066\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u3092\u884c\u3044\u3001\u305d\u306e\u7d50\u679c\u3092\u5143\u306b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u306e\u691c\u8a3c\u3092\u884c\u3063\u305f\u7d50\u679c\u3001miR-455-3p\u3068miR-4668-5p\u306e2\u7a2e\u985e\u306emiRNA\u304c\u6709\u610f\u306b\u767a\u73fe\u5897\u52a0\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f<sup>17)\u3002\u3055\u3089\u306b\u30c8\u30e9\u30f3\u30b9\u30b8\u30a7\u30cb\u30c3\u30af\u30de\u30a6\u30b9\u306b\u304a\u3044\u3066\u3082\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3066\u3044\u308b\u8133\u306e\u5927\u8133\u76ae\u8cea\u9818\u57df\u3067\u306f\u3001mmu-miR-455-3p\u304c\u9ad8\u30ec\u30d9\u30eb\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u5f71\u97ff\u3092\u53d7\u3051\u3066\u3044\u306a\u3044\u5c0f\u8133\u9818\u57df\u3067\u306f\u4f4e\u30ec\u30d9\u30eb\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30d1\u30b9\u30a6\u30a7\u30a4\u89e3\u6790\u304b\u3089miR-455-3p\u306f\u3044\u304f\u3064\u304b\u306e\u751f\u7269\u5b66\u7684\u7d4c\u8def\u306e\u8abf\u7bc0\u306b\u95a2\u9023\u3057\u3066\u3044\u3066\u3001\u3053\u308c\u3089\u306e\u7d4c\u8def\u306b\u95a2\u9023\u3059\u308b\u907a\u4f1d\u5b50\u306f\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u306e\u75c5\u56e0\u306b\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002 \u4ee5\u4e0a\u306e\u3053\u3068\u304b\u3089\u3001\u30a2\u30eb\u30c4\u30cf\u30a4\u30de\u30fc\u75c5\u60a3\u8005\u306b\u898b\u3089\u308c\u308bmiR-455-3p\u306e\u767a\u73fe\u5897\u52a0\u306f\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u3057\u3066\u306e\u5f79\u5272\u3092\u793a\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4ee5\u4e0a\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306b\u304a\u3051\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u3066\u304d\u307e\u3057\u305f\u3002<\/p>\n<p>GeneChip 3\u2019 IVT Array\u306f\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u306e\u30c7\u30b6\u30a4\u30f3\u3092\u8e0f\u8972\u3057\u3066\u304a\u308a\u3001\u8ad6\u6587\u6570\u3084\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3078\u306e\u767b\u9332\u6570\u3082\u6570\u591a\u3044\u305f\u3081\u3001\u305d\u308c\u3089\u306e\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3092\u5229\u7528\u3057\u305f\u308a\u3001\u904e\u53bb\u306e\u4f8b\u3068\u3054\u81ea\u8eab\u306e\u7814\u7a76\u3092\u6bd4\u8f03\u3057\u305f\u308a\u3059\u308b\u5834\u5408\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001Clariom Array\u306e\u3088\u3046\u306aWT Array\u306f\u3001\u5168\u8ee2\u5199\u9818\u57df\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u3057\u305f\u65b0\u3057\u3044\u30c7\u30b6\u30a4\u30f3\u304b\u3089\u306a\u308a\u3001\u65b0\u898f\u306b\u7814\u7a76\u3092\u59cb\u3081\u308b\u5834\u5408\u306b\u304a\u3059\u3059\u3081\u3067\u3059\u3002\u4e00\u65b9\u3001GeneChip miRNA Array\u306f\u3001\u591a\u304f\u306e\u751f\u547d\u73fe\u8c61\u306b\u95a2\u308f\u308b\u9396\u9577\u306e\u77ed\u3044non-coding RNA\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u306b\u3057\u305f\u7814\u7a76\u306b\u5229\u7528\u3067\u304d\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306e\u88fd\u54c1\u306b\u3064\u3044\u3066\u306f\u4ee5\u4e0b\u306e\u30ea\u30f3\u30af\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><strong>\u30fb<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/900466?CID=gsd_mic_gex_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_oc_s00_ma21_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneChip\u2122 Human Genome U133 Plus 2.0 Array<\/a><\/strong><br \/>\n<strong>\u30fb<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/transcriptome-profiling-microarrays\/clariom-assays.html?CID=gsd_mic_gex_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_oc_s00_ma21_Social_LAB\" target=\"_blank\" rel=\"noopener\">Clariom\u30a2\u30c3\u30bb\u30a4<\/a><\/strong><br \/>\n<strong>\u30fb<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/mirna-profiling-microarrays.html?CID=gsd_mic_gex_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_oc_s00_ma21_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f miRNA \u30d7\u30ed\u30d5\u30a1\u30a4\u30ea\u30f3\u30b0<\/a><\/strong><\/p>\n<p>\u3053\u306e\u4e8b\u4f8b\u3067\u4f7f\u7528\u3057\u3066\u3044\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u5f0a\u793e\u304c\u63d0\u4f9b\u3057\u3066\u3044\u308b\u30d5\u30ea\u30fc\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3001Applied Biosystems\u2122 Transcriptome Analysis Console\uff08TAC\uff09\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u4f7f\u3048\u3070\u3001\u30d0\u30a4\u30aa\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u306b\u7cbe\u901a\u3057\u3066\u3044\u306a\u304f\u3066\u3082\u7c21\u5358\u306b\u30c7\u30fc\u30bf\u89e3\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/microarray-analysis-instruments-software-services\/microarray-analysis-software\/affymetrix-transcriptome-analysis-console-software.html?CID=gsd_mic_gex_r04_jp_cp1484_pjt8669_gsd00000_0so_blg_op_awa_oc_s00_ma21_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TAC\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u89e3\u6790\u306f\u3001\u4eca\u56de\u7d39\u4ecb\u3057\u307e\u3057\u305f\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u3088\u3046\u306aRNA\u89e3\u6790\u3060\u3051\u3067\u306a\u304f\u3001\u67d3\u8272\u4f53DNA\u3092\u4f7f\u3063\u305fSNP genotyping\u304b\u3089\u306eGenome-Wide Association Study\uff08GWAS\uff09\u306b\u3088\u308b\u75be\u60a3\u539f\u56e0\u907a\u4f1d\u5b50\u9818\u57df\u306e\u63a2\u7d22\u3084\u3001\u67d3\u8272\u4f53\u306e\u30b3\u30d4\u30fc\u6570\u7570\u5e38\u3092\u691c\u51fa\u3059\u308b\u67d3\u8272\u4f53\u30b3\u30d4\u30fc\u6570\u89e3\u6790\u306b\u3082\u5229\u7528\u53ef\u80fd\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u3061\u3089\u306b\u3064\u3044\u3066\u306f\u3001\u6539\u3081\u3066\u7d39\u4ecb\u3067\u304d\u305f\u3089\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u53c2\u8003\u6587\u732e<br \/>\n1)Golub, T.R. et al. Science 286, 531-537, 1999<br \/>\n2)Wang, Y. et al. Lancet 365, 671-679, 2005<br \/>\n3)Foekens, J. A. et al. J. Clin. Oncol. 24, 1665-1671, 2006<br \/>\n4)Ueda, H. R. et al. J. Biol.Chem. 277, 14048-14052, 2002<br \/>\n5)Gene Expression Omnibus, https:\/\/www.ncbi.nlm.nih.gov\/geo\/<br \/>\n6)ArrayExpress, https:\/\/www.ebi.ac.uk\/arrayexpress\/<br \/>\n7)Naoi, Y. et al. Breast Cancer Res. Treat. 128, 633-641, 2011<br \/>\n8)Lawrence, H. B. et al. Cell 74, 597-606, 1993<br \/>\n9)Masood, K. I. et al. Scientific Reports 11, 22958, 2021<br \/>\n10)Taniguchi-Ponciano, K. et al. Genes 11, 1422, 2020<br \/>\n11)Wang, M. et al. Scientific Reports 7, 2079, 2017<br \/>\n12)Ambros, V. Nature 431, 350-355, 2004<br \/>\n13)Murphy, D. et al. BMC Evol. Biol. 8, 92, 2008<br \/>\n14)Mitchell, P. S. et al. Proc. Natl. Acad. Sci. USA 105, 10513\u201310518, 2008<br \/>\n15)Montani, F. et al. J Natl Cancer Inst. 107, djv063, 2015<br \/>\n16)Yong, F. L. et al. BMC Cancer 13, 280, 2013<br \/>\n17)Kumar, S. et al. Human Mol. Genet. 26, 3808-3822, 2017<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u3001\u65e2\u306b20\u5e74\u4ee5\u4e0a\u304c\u7d4c\u904e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u89e3\u6790\u6280\u8853\u306f\u73fe\u5728\u3067\u3082\u9032\u5316\u3092\u7d9a\u3051\u3001\u533b\u5b66\u5206\u91ce\u3060\u3051\u3067\u306a\u304f\u3001\u751f\u547d\u73fe\u8c61\u306b\u95a2\u9023\u3057\u305f\u57fa\u790e\u7814\u7a76\u5206\u91ce\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u3053\u306e\u89e3\u6790\u306f<\/p>\n","protected":false},"author":975,"featured_media":10017,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71,189],"division":[],"class_list":["post-11327","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","tag-gene-expression","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09\" \/>\n<meta property=\"og:description\" content=\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u3001\u65e2\u306b20\u5e74\u4ee5\u4e0a\u304c\u7d4c\u904e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u89e3\u6790\u6280\u8853\u306f\u73fe\u5728\u3067\u3082\u9032\u5316\u3092\u7d9a\u3051\u3001\u533b\u5b66\u5206\u91ce\u3060\u3051\u3067\u306a\u304f\u3001\u751f\u547d\u73fe\u8c61\u306b\u95a2\u9023\u3057\u305f\u57fa\u790e\u7814\u7a76\u5206\u91ce\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u3053\u306e\u89e3\u6790\u306f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-01T01:44:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-04T05:17:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1706\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"21\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09\",\"datePublished\":\"2022-04-01T01:44:58+00:00\",\"dateModified\":\"2022-04-04T05:17:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/\"},\"wordCount\":398,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_558263062-scaled.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\",\"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/\",\"name\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_558263062-scaled.jpg\",\"datePublished\":\"2022-04-01T01:44:58+00:00\",\"dateModified\":\"2022-04-04T05:17:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_558263062-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2021\\\/01\\\/shutterstock_558263062-scaled.jpg\",\"width\":2560,\"height\":1706},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_analysis_application_ma_gsd_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09","og_description":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u4f7f\u7528\u3057\u305f\u89e3\u6790\u304c\u767b\u5834\u3057\u3066\u304b\u3089\u3001\u65e2\u306b20\u5e74\u4ee5\u4e0a\u304c\u7d4c\u904e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u89e3\u6790\u6280\u8853\u306f\u73fe\u5728\u3067\u3082\u9032\u5316\u3092\u7d9a\u3051\u3001\u533b\u5b66\u5206\u91ce\u3060\u3051\u3067\u306a\u304f\u3001\u751f\u547d\u73fe\u8c61\u306b\u95a2\u9023\u3057\u305f\u57fa\u790e\u7814\u7a76\u5206\u91ce\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u3053\u306e\u89e3\u6790\u306f","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-04-01T01:44:58+00:00","article_modified_time":"2022-04-04T05:17:13+00:00","og_image":[{"width":2560,"height":1706,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"21\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09","datePublished":"2022-04-01T01:44:58+00:00","dateModified":"2022-04-04T05:17:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/"},"wordCount":398,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/","name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","datePublished":"2022-04-01T01:44:58+00:00","dateModified":"2022-04-04T05:17:13+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","width":2560,"height":1706},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_analysis_application_ma_gsd_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6d3b\u7528\u4e8b\u4f8b\uff08RNA\u89e3\u6790\u7de8\uff09"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"},{"value":189,"label":"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-1024x683.jpg",760,507,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]},{"term_id":189,"name":"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790","slug":"gene-expression","term_group":0,"term_taxonomy_id":189,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":11327,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":11327,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":11327,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":11327,"position":3},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":11327,"position":4},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":11327,"position":5},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2021\/01\/shutterstock_558263062-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=11327"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11327\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/10017"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=11327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=11327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=11327"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=11327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}