{"id":114,"date":"2015-10-15T00:00:00","date_gmt":"2015-10-15T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/"},"modified":"2024-08-27T11:40:28","modified_gmt":"2024-08-27T02:40:28","slug":"ecoli-genotype","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/","title":{"rendered":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081"},"content":{"rendered":"<p>\u88fd\u54c1\u30ab\u30bf\u30ed\u30b0\u3067\u30b3\u30f3\u30d4\u30c6\u30f3\u30c8\u30bb\u30eb\u3092\u63a2\u3057\u3066\u3044\u308b\u3068\u3001\u6b20\u640d\u3057\u3066\u3044\u308b\u907a\u4f1d\u5b50\u304c\u8868\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30d1\u30c3\u3068\u898b\u3067\u3069\u3093\u306a\u6a5f\u80fd\u304c\u6b20\u640d\u3057\u3066\u3044\u308b\u306e\u304b\u3088\u304f\u5206\u304b\u308a\u307e\u305b\u3093\u3088\u306d\uff1f<\/p>\n<p>\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u3088\u304f\u4f7f\u7528\u3055\u308c\u308b\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01<\/p>\n<h2>\u5927\u8178\u83cc\u30db\u30b9\u30c8\u306e\u907a\u4f1d\u5b50\u578b<\/h2>\n<table class=\"productList\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"3\">\n<tbody>\n<tr>\n<th valign=\"top\">\u5927\u8178\u83cc\u540d<\/th>\n<th width=\"10\"><\/th>\n<th valign=\"top\">\u907a\u4f1d\u5b50\u578b<\/th>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C607003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21-AI<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm ara<\/i>B::<i>T7RNAP-tetA<\/i><\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C600003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21(DE3)<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm <\/i>(DE3)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C606003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21(DE3)pLysS<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm <\/i>(DE3) pLysS (Cam<sup>R<\/sup>)<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C656503?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21(DE3)pLysE<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm <\/i>(DE3) pLysE (Cam<sup>R<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C601003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21 Star\u2122(DE3)<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm rne<\/i>131 (DE3)<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C602003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">BL21 Star\u2122 (DE3)pLysS<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>omp<\/i>T <i>hsd<\/i>SB(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>gal dcm rne<\/i>131 (DE3) pLysS (Cam<sup>R<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A10460?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\"><i>ccd<\/i>B Survival\u21222<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F- <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>ara<\/i>\u0394139 \u0394(<i>ara<\/i>&#8211;<i>leu<\/i>)7697 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L (Str<sup>R<\/sup>) <i>end<\/i>A1 <i>nup<\/i>G<i> fhuA::IS2<\/i><\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\">DB3.1\u2122<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>gyr<\/i>A462 <i>end<\/i>A1 \u0394(sr1-<i>rec<\/i>A) <i>mcr<\/i>B <i>mrr hsd<\/i>S20(r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>sup<\/i>E44 <i>ara<\/i>-14 <i>gal<\/i>K2 <i>lac<\/i>Y1 <i>pro<\/i>A2 <i>rps<\/i>L20(Sm<sup>R<\/sup>) <i>xyl<\/i>-5 \u03bb\u2013 <i>leu mtl<\/i>1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/18258012?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH5\u03b1\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> \u03a680<i>lac<\/i>Z\u0394M15 \u0394(<i>lac<\/i>ZYA-<i>arg<\/i>F) U169 <i>rec<\/i>A1 <i>end<\/i>A1 <i>hsd<\/i>R17 (r<sub>K<\/sub><sup>\u2013<\/sup>, m<sub>K<\/sub><sup>+<\/sup>) <i>pho<\/i>A <i>sup<\/i>E44 \u03bb\u2013 <i>thi<\/i>-1 <i>gyr<\/i>A96 <i>rel<\/i>A1<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12297016?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH5\u03b1\u2122 T1<sup>R<\/sup><\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> \u03a680<i>lac<\/i>Z\u0394M15 \u0394(<i>lac<\/i>ZYA-<i>arg<\/i>F)U169 <i>rec<\/i>A1 <i>end<\/i>A1 <i>hsd<\/i>R17 (r<sub>K<\/sub><sup>\u2013<\/sup>, m<sub>K<\/sub><sup>+<\/sup>) <i>pho<\/i>A <i>sup<\/i>E44 <i>thi<\/i>-1 <i>gyr<\/i>A96 <i>rel<\/i>A1 <i>ton<\/i>A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/18297010?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH10B\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>end<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>) 7697 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L <i>nup<\/i>G \u03bb\u2013<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12331013?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH10B\u2122 T1<sup>R<\/sup><\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>end<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>) 7697 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L <i>nup<\/i>G \u03bb\u2013 <i>ton<\/i>A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10361012?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH10Bac\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>end<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>) 7697 <i>gal<\/i>U <i>gal<\/i>K \u03bb\u2013 <i>rps<\/i>L <i>nup<\/i>G\/ pMON14272\/pMON7124<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/18312017?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">DH12S\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u03a680d <i>lac<\/i>Z \u0394M15 <i>mcrA<\/i> \u0394(<i>mrr-hsd<\/i>RMS-mcrBC) <i>ara<\/i>D139 \u0394(<i>ara, leu<\/i>)7697 \u0394<i>lac<\/i>X74 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L(Str<sup>R<\/sup>) <i>nup<\/i>G <i>rec<\/i>A1 \/ F\u2019 {<i>pro<\/i>AB<sup>+<\/sup> <i>lac<\/i>I<sup>q<\/sup> <i>lac<\/i>ZDM15}<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C717103?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">INV110<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F\u00b4 {<i>tra<\/i>\u039436 <i>pro<\/i>AB <i>lac<\/i>Iq <i>lac<\/i>Z\u0394M15} <i>rps<\/i>L (Str<sup>R<\/sup>) <i>thr leu end<\/i>A <i>thi<\/i>-1 <i>lac<\/i>Y <i>gal<\/i>K <i>gal<\/i>T <i>ara ton<\/i>A <i>tsx dam dcm sup<\/i>E44 \u0394(<i>lac<\/i>&#8211;<i>pro<\/i>AB) \u0394(<i>mcr<\/i>C-<i>mrr<\/i>)102::Tn10 (Tet<sup>R<\/sup>)<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"http:\/\/www.thermofisher.com\/order\/catalog\/product\/C202003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">INV\u03b1F\u00b4<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F\u00b4 <i>end<\/i>A1 <i>rec<\/i>A1 <i>hsd<\/i>R17 (r<sub>K<\/sub><sup>\u2013<\/sup>, m<sub>K<\/sub><sup>+<\/sup>) <i>sup<\/i>E44 <i>thi<\/i>-1 <i>gyr<\/i>A96 <i>rel<\/i>A1 \u03a680<i>lac<\/i>Z \u0394M15 \u0394<i>lac<\/i>ZYA-<i>arg<\/i>F<i>)U169<\/i><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C862003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Mach1\u2122 T1<sup>R<\/sup><\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>hsd<\/i>R(r<sub>K<\/sub><sup>\u2013<\/sup>, m<sub>K<\/sub><sup>+<\/sup>) \u0394<i>rec<\/i>A1398 <i>end<\/i>A1 <i>ton<\/i>A<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C640003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">MegaX DH10B\u2122 T1<sup>R<\/sup><\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>end<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>)7697 <i>gal<\/i>U <i>gal<\/i>K \u03bb\u2013 <i>rps<\/i>L <i>nup<\/i>G <i>ton<\/i>A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C854003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">OmniMAX\u2122 2 T1<sup>R<\/sup><\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F\u00b4 {<i>pro<\/i>AB+ <i>lac<\/i>Iq <i>lac<\/i>Z\u0394M15 Tn10(Tet<sup>R<\/sup>) \u0394(<i>ccd<\/i>AB)} <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394(<i>lac<\/i>ZYA-<i>arg<\/i>F) U169 <i>end<\/i>A1 <i>rec<\/i>A1 <i>sup<\/i>E44 <i>thi<\/i>-1 <i>gyr<\/i>A96 <i>rel<\/i>A1 <i>ton<\/i>A <i>pan<\/i>D<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C101010?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">PIR1<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>\u2206lac<\/i>169<i> rpo<\/i>S(am)<i> rob<\/i>A1<i> cre<\/i>C510<i> hsd<\/i>R514<i> end<\/i>A<i> rec<\/i>A1<i> uidA(\u2206Mlu I)::pir-116<\/i><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C111110?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">PIR2<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>\u2206lac<\/i>169<i> rpo<\/i>S(am) <i>rob<\/i>A1<i> cre<\/i>C510<i> hsd<\/i>R514<i> end<\/i>A<i> rec<\/i>A1<i> uidA(\u2206Mlu I)::pir<\/i><\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10268019?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Stbl2\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mcr<\/i>BC-<i>hsd<\/i>RMS-<i>mrr<\/i>) <i>rec<\/i>A1 <i>end<\/i>A1 <i>lon gyr<\/i>A96 <i>thi sup<\/i>E44 <i>rel<\/i>A1 \u03bb\u2013 \u0394(<i>lac<\/i>&#8211;<i>pro<\/i>AB)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C737303?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Stbl3\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>B <i>mrr hsd<\/i>S20 (r<sub>B<\/sub><sup>\u2013<\/sup>, m<sub>B<\/sub><sup>\u2013<\/sup>) <i>rec<\/i>A13 <i>sup<\/i>E44 <i>ara<\/i>-14 <i>gal<\/i>K2 <i>lac<\/i>Y1 <i>pro<\/i>A2 <i>rps<\/i>L20 (StrR ) <i>xyl<\/i>-5 \u03bb\u2013 <i>leu mtl<\/i>-1<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11635018?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Stbl4\u2122<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>mcr<\/i>A \u0394(<i>mcr<\/i>BC-<i>hsd<\/i>RMS-<i>mrr<\/i>) <i>rec<\/i>A1 <i>end<\/i>A1 <i>gyr<\/i>A96 <i>gal<\/i>&#8211; <i>thi<\/i>-1 <i>sup<\/i>E44 \u03bb\u2013 <i>rel<\/i>A1 \u0394(<i>lac<\/i>&#8211;<i>pro<\/i>AB)\/F\u00b4 <i>pro<\/i>AB+ <i>lac<\/i>IqZ\u0394M15 Tn10 (Tet<sup>R<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C404003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TOP10<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F<sup>\u2013<\/sup> <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>) 7697 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L (Str<sup>R<\/sup>) <i>end<\/i>A1 <i>nup<\/i>G<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C303003?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TOP10F\u2019<\/a><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">F\u00b4{<i>lac<\/i>Iq, Tn<i>10<\/i>(Tet<sup>R<\/sup>)} <i>mcr<\/i>A \u0394(<i>mrr<\/i>&#8211;<i>hsd<\/i>RMS-<i>mcr<\/i>BC) \u03a680<i>lac<\/i>Z\u0394M15 \u0394<i>lac<\/i>X74 <i>rec<\/i>A1 <i>ara<\/i>D139 \u0394(<i>ara leu<\/i>) 7697 <i>gal<\/i>U <i>gal<\/i>K <i>rps<\/i>L (Str<sup>R<\/sup>) <i>end<\/i>A1 <i>nup<\/i>G<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>P3\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u4fdd\u6301\u3057\u3066\u3044\u308b\u5927\u8178\u83cc\u306e\u5897\u6b96\u306b\u3064\u3044\u3066<\/h2>\n<p>P3 \u30d7\u30e9\u30b9\u30df\u30c9\u3092\u6301\u3063\u3066\u3044\u308b\u5927\u8178\u83cc\u3067\u306f\u3001tRNA\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc F\u907a\u4f1d\u5b50(<i>sup<\/i>F)\u3092\u30b3\u30fc\u30c9\u3057\u3066\u3044\u308b\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u7dad\u6301\u3084\u9078\u629e\u304c\u53ef\u80fd\u3067\u3059\u3002P3\u306f\u4f4e\u30b3\u30d4\u30fc\u306e60 kb\u306e\u30a8\u30d4\u30bd\u30fc\u30e0\u30d7\u30e9\u30b9\u30df\u30c9\u3067\u3001\u30ab\u30ca\u30de\u30a4\u30b7\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u3068\u3001\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u3068\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u305d\u308c\u305e\u308c\u306e\u8010\u6027\u907a\u4f1d\u5b50\u306e\u30a2\u30f3\u30d0\u30fc\u5909\u7570\u30df\u30e5\u30fc\u30bf\u30f3\u30c8\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001P3\u306e\u307f\u3092\u4fdd\u6301\u3057\u305f\u5927\u8178\u83cc\u306f\u3001\u30ab\u30ca\u30de\u30a4\u30b7\u30f3\u306b\u306f\u8010\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u3001\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u306b\u306f\u611f\u53d7\u6027\u304c\u3042\u308a\u307e\u3059\u3002P3 \u30d7\u30e9\u30b9\u30df\u30c9\u3092\u6301\u3063\u305f\u5927\u8178\u83cc\u306b<i>sup<\/i>F\u30d7\u30e9\u30b9\u30df\u30c9(\u4f8b\u3048\u3070pcDNA1.1\u3084pCM8\u306a\u3069)\u3067\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30e0\u3059\u308b\u3068\u3001\u305d\u308c\u3089\u306f\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u3001\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u3078\u306e\u8010\u6027\u3092\u7372\u5f97\u3057\u307e\u3059\u3002\u307e\u305f\u30a2\u30f3\u30d0\u30fc\u5909\u7570\u304c\u3082\u3068\u306b\u623b\u308b\u7387\u306f\u304b\u306a\u308a\u9ad8\u3044\u306e\u3067\u3001\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u3068\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u306e\u4e21\u65b9\u3067\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u4fee\u5fa9\u3055\u308c\u305f\u5927\u8178\u83cc\u682a\u304c\u5897\u3048\u308b\u306e\u3092\u3055\u3051\u308b\u305f\u3081\u306b\u3001\u57f9\u5730\u306b\u306f\u3001\u6bd4\u8f03\u7684\u4f4e\u6fc3\u5ea6\u306e\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3(7.5 -10 \u03bcg\/ml)\u3068\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3(25-40 \u03bcg\/ml)\u3092\u52a0\u3048\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n<h2>\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b<\/h2>\n<table class=\"productList\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"3\">\n<tbody>\n<tr>\n<th valign=\"top\">\u907a\u4f1d\u5b50\u540d<\/th>\n<th width=\"10\"><\/th>\n<th valign=\"top\">\u5185\u5bb9<\/th>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>ara<\/i>-14<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30a2\u30e9\u30d3\u30ce\u30fc\u30b9\u306e\u4ee3\u8b1d\u304c\u3067\u304d\u306a\u3044\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>arg<\/i>F<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30aa\u30eb\u30cb\u30c1\u30f3\u30ab\u30eb\u30d0\u30e2\u30a4\u30eb\u8ee2\u79fb\u9175\u7d20\u306e\u5909\u7570\u3002\u30a2\u30eb\u30ae\u30cb\u30f3\u306e\u4ee3\u8b1d\u3092\u963b\u5bb3\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>dam\/dcm<\/i><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">GATC\u914d\u5217\u4e2d\u306e\u30a2\u30c7\u30cb\u30f3\u306e\u30e1\u30c1\u30eb\u5316(<i>dam<\/i>) \u307e\u305f\u306fCCWGG\u914d\u5217\u4e2d\u306e\u30b7\u30c8\u30b7\u30f3\u306e\u30e1\u30c1\u30eb\u5316(<i>dcm<\/i>) \u304c\u8d77\u3053\u3089\u306a\u3044\u3088\u3046\u306a\u5909\u7570\u3002\u30e1\u30c1\u30eb\u5316\u306b\u3088\u308a\u6d3b\u6027\u306b\u5f71\u97ff\u3092\u53d7\u3051\u308b\u5236\u9650\u9175\u7d20(<i>Ava<\/i>II\u3001<i>Bcl<\/i>II\u306a\u3069)\u3067\u5207\u65ad\u3059\u308b\u305f\u3081\u306eDNA\u306e\u5897\u6b96\u306b\u5229\u7528\u3055\u308c\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\">DE3<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">T7 RNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u3092\u30b3\u30fc\u30c9\u3059\u308b\u6eb6\u539f\u83cc\u3002T7-\u767a\u73fe\u7cfb\u3067\u306e\u8a98\u5c0e\u767a\u73fe\u306b\u7528\u3044\u3089\u308c\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>deo<\/i>R<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30c7\u30aa\u30ad\u30b7\u30ea\u30dc\u30fc\u30b9\u5408\u6210\u306b\u95a2\u9023\u3057\u305f\u907a\u4f1d\u5b50\u306e\u6052\u5e38\u7684\u767a\u73fe\u3092\u53ef\u80fd\u306b\u3059\u308b\u5236\u5fa1\u907a\u4f1d\u5b50\u3002\u5927\u304d\u306aDNA\u3092\u52b9\u7387\u7684\u306b\u53d6\u308a\u8fbc\u307f\u306b\u304f\u304f\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>end<\/i>A (<i>end<\/i>A1)<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u975e\u7279\u7570\u7684\u30a8\u30f3\u30c9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u3001\u30a8\u30f3\u30c9\u30cc\u30af\u30ec\u30a2\u30fc\u30bcI \u306e\u5909\u7570\u3002\u975e\u7279\u7570\u7684\u30a8\u30f3\u30c9\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u6d3b\u6027\u3092\u9664\u3044\u305f\u306e\u3067\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u8abf\u88fd\u304c\u6539\u5584\u3055\u308c\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">F&#8217;<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">M13\u30d5\u30a1\u30fc\u30b8\u3067\u611f\u67d3\u3055\u305b\u305f\u969b\u306e\u4e00\u672c\u9396DNA\u306e\u751f\u6210\u306b\u7528\u3044\u3089\u308c\u308b\u3001\u81ea\u5df1\u4f1d\u64ad\u6027\u306e\u30d7\u30e9\u30b9\u30df\u30c9\u3002F&#8217;\u306b\u306f\u305d\u306e\u7dad\u6301\u3092\u53ef\u80fd\u306b\u3059\u308b\u8010\u6027\u30de\u30fc\u30ab\u30fc\u3092\u542b\u3080\u3053\u3068\u304c\u591a\u304f\u3001<i>lac<\/i>I\u304a\u3088\u3073<i>lac<\/i>Z\u0394M15\u907a\u4f1d\u5b50\u578b\u3092\u4fdd\u6709\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>gal<\/i>K<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30ac\u30e9\u30af\u30c8\u30ad\u30ca\u30fc\u30bc\u306e\u5909\u7570\u306b\u3088\u308a\u30ac\u30e9\u30af\u30c8\u30fc\u30b9\u306e\u4ee3\u8b1d\u304c\u3067\u304d\u306a\u3044\u3002<i>gal<\/i>K-\u306e\u5927\u8178\u83cc\u306f\u30e9\u30af\u30c8\u30fc\u30b9\u3092\u552f\u4e00\u306e\u70ad\u7d20\u6e90\u3068\u3059\u308b\u74b0\u5883\u4e0b\u3067\u5897\u6b96\u3067\u304d\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>gal<\/i>U<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30b0\u30eb\u30b3\u30fc\u30b9-1-\u30ea\u30f3\u9178\u30a6\u30ea\u30b8\u30ea\u30eb\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30e9\u30fc\u30bc\u306e\u7a81\u7136\u5909\u7570\u306b\u3088\u308a\u30ac\u30e9\u30af\u30c8\u30fc\u30b9\u304c\u5229\u7528\u3067\u304d\u306a\u3044\u3002<i>gal<\/i>U-\u306e\u5927\u8178\u83cc\u306f\u30ac\u30e9\u30af\u30c8\u30fc\u30b9\u304c\u552f\u4e00\u306e\u70ad\u7d20\u6e90\u3067\u3042\u308b\u57f9\u990a\u6db2\u3067\u5897\u6b96\u3067\u304d\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>gyr<\/i>A96<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">DNA\u30b8\u30e3\u30a4\u30ec\u30fc\u30b9\u306e\u5909\u7570\u3002\u30ca\u30ea\u30b8\u30af\u30b9\u9178\u306b\u5bfe\u3057\u3066\u8010\u6027\u3092\u793a\u3059\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>hsd<\/i><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u5927\u8178\u83cc\u304c\u5916\u6765DNA\u3092\u8a8d\u8b58\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u306b\u3059\u308b\u30e1\u30c1\u30eb\u5316\u304a\u3088\u3073\u5236\u9650\u5207\u65ad\u306e\u30b7\u30b9\u30c6\u30e0\u306e\u5909\u7570\u3002<i>hsd<\/i>\u907a\u4f1d\u5b50\u578b\u306fPCR\u53cd\u5fdc\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u305fDNA\u306e\u52b9\u7387\u7684\u306a\u30c8\u30e9\u30f3\u30b9\u30d5\u30a9\u30fc\u30e1\u30fc\u30b7\u30e7\u30f3\u3092\u53ef\u80fd\u306b\u3059\u308b\u3002<br \/>\n*<i>hsd<\/i>R-\u975e\u30e1\u30c1\u30eb\u5316<i>Eco<\/i>KI\u90e8\u4f4d\u306e\u5236\u9650\u5207\u65ad\u3092\u53d6\u308a\u9664\u304f(1)\u3002<br \/>\n**<i>hsd<\/i>RMS-\u975e\u30e1\u30c1\u30eb\u5316<i>Eco<\/i>KI\u90e8\u4f4d\u306e\u5236\u9650\u5207\u65ad\u3068<i>Eco<\/i>KI\u90e8\u4f4d\u306e\u30e1\u30c1\u30eb\u5316\u3092\u540c\u6642\u306b\u53d6\u308a\u9664\u304f(1)\u3002<br \/>\n\u2020<i>hsd<\/i>S-<i>Eco<\/i>B\u90e8\u4f4d\u306e\u5236\u9650\u3068\u30e1\u30c1\u30eb\u5316\u3092\u540c\u6642\u306b\u53d6\u308a\u9664\u304f(2)\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>lac<\/i>I(<i>lac<\/i>I<sub>q<\/sub>)<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>lac<\/i>\u30aa\u30da\u30ec\u30fc\u30bf\u3092\u6709\u3059\u308b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304b\u3089\u306e\u767a\u73fe\u3092\u5236\u5fa1\u3059\u308b<i>lac<\/i>\u30ea\u30d7\u30ec\u30c3\u30b5\u30fc\u3092\u30b3\u30fc\u30c9\u3059\u308b\u3002IPTG\u304c<i>lac<\/i>\u30ea\u30d7\u30ec\u30c3\u30b5\u30fc\u3068\u7d50\u5408\u3057\u3066\u305d\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u6291\u5236\u3092\u89e3\u9664\u3059\u308b\u3002blue\/white\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092\u884c\u3063\u305f\u308a\u3001\u7d44\u63db\u3048\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u305f\u3081\u306b\u7528\u3044\u3089\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>lac<\/i>y1<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>\u03b2<\/i>-D-\u30ac\u30e9\u30af\u30c8\u30b7\u30c0\u30fc\u30bc\u306e\u5909\u7570\u3002\u3053\u308c\u306b\u3088\u308a\u30e9\u30af\u30c8\u30fc\u30b9\u306e\u4ee3\u8b1d\u3092\u963b\u5bb3\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>lac<\/i>Z<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>\u03b2<\/i>-D-\u30ac\u30e9\u30af\u30c8\u30b7\u30c0\u30fc\u30bc\u907a\u4f1d\u5b50\u3002\u3053\u308c\u306b\u5909\u7570\u304c\u751f\u3058\u308b\u3068X-gal\u306e\u5b58\u5728\u4e0b\u3067\u7121\u8272(\u5909\u7570\u304c\u306a\u3044\u5834\u5408\u306f\u9752)\u306e\u30b3\u30ed\u30cb\u30fc\u304c\u751f\u6210\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>lac<\/i>Z\u2206M15<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>lac<\/i>Z\u907a\u4f1d\u5b50\u306e\u03b1-\u76f8\u88dc\u6027\u3092\u6709\u3057\u305f\u90e8\u5206\u6b20\u5931\u907a\u4f1d\u5b50\u3002\u7d44\u63db\u3048\u4f53\u306eblue\/white\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u7528\u3044\u3089\u308c\u308b\u3002\u901a\u5e38\u3001\u30e9\u30e0\u30c0\u72b6\u30d7\u30ed\u30d5\u30a1\u30fc\u30b8\u03c680\u307e\u305f\u306fF&#8217;\u4e0a\u306b\u5b58\u5728\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>leu<\/i>B<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\"><i>\u03b2<\/i>-\u30a4\u30bd\u30d7\u30ed\u30d4\u30eb\u30ea\u30f3\u30b4\u9178\u30c7\u30d2\u30c9\u30ed\u30b2\u30ca\u30fc\u30bc\u306e\u5909\u7570\u3002\u5897\u6b96\u306b\u306f\u6700\u5c11\u57f9\u5730\u306b\u30ed\u30a4\u30b7\u30f3\u306e\u6dfb\u52a0\u3092\u5fc5\u8981\u3068\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>lon<\/i><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">Lon ATPase-\u4f9d\u5b58\u6027\u30d7\u30ed\u30c6\u30a2\u30fc\u30bc\u306e\u6b20\u640d\u3002\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5206\u89e3\u3092\u6291\u5236\u3002B\u682a\u306f\u3059\u3079\u3066\u3053\u306e\u5909\u7570\u3092\u4fdd\u6709\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>mcr<\/i>A, <i>mcr<\/i>BC, <i>mrr<\/i><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30e1\u30c1\u30eb\u5316DNA\u3092\u5916\u6765DNA\u3068\u3057\u3066\u8a8d\u8b58\u3067\u304d\u306a\u304f\u3059\u308b\u5909\u7570\u3002\u30b2\u30ce\u30e0DNA\u3084\u30e1\u30c1\u30eb\u5316cDNA\u3092\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3059\u308b\u969b\u306b\u3053\u306e\u907a\u4f1d\u5b50\u578b\u304c\u5fc5\u8981\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>nup<\/i>G<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30cc\u30af\u30ec\u30aa\u30b7\u30c9\u8f38\u9001\u7cfb\u306e\u5909\u7570\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>omp<\/i>T<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u5916\u90e8\u7d30\u80de\u819c\u30d7\u30ed\u30c6\u30a2\u30fc\u30bc\u3092\u6b20\u3044\u305f\u5927\u8178\u83cc\u3002\u83cc\u682a\u5185\u3067\u767a\u73fe\u3055\u308c\u305f\u7570\u7a2e\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5206\u89e3\u3092\u6291\u5236\u3059\u308b\u3002<i>Omp<\/i>T<sup>&#8211;<\/sup>\u682a\u3067\u306f\u5206\u89e3\u3092\u53d7\u3051\u3066\u3044\u306a\u3044\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u56de\u53ce\u7387\u304c\u5411\u4e0a\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">P3<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30a2\u30f3\u30d0\u30fc\u5909\u7570\u3092\u6709\u3057\u305f\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304a\u3088\u3073\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u3092\u4fdd\u6709\u3059\u308b60 kb\u306e\u4f4e\u30b3\u30d4\u30fc\u30d7\u30e9\u30b9\u30df\u30c9\u3002\u4e3b\u306b<i>sup<\/i>F-\u542b\u6709\u30d7\u30e9\u30b9\u30df\u30c9\u306e\u9078\u629e\u306b\u7528\u3044\u3089\u308c\u308b\u3002\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u7528\u306e\u30ab\u30ca\u30de\u30a4\u30b7\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u304c\u3042\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\">pLys<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">T7\u30ea\u30be\u30c1\u30fc\u30e0\u3092\u30b3\u30fc\u30c9\u3059\u308b\u30d7\u30e9\u30b9\u30df\u30c9\u3002T7 RNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306e\u57fa\u5e95\u30ec\u30d9\u30eb\u3092\u6291\u5236\u3059\u308b\u3053\u3068\u306b\u3088\u308aT7-\u8a98\u5c0e\u767a\u73fe\u7cfb\u306b\u304a\u3051\u308b\u57fa\u5e95\u767a\u73fe\u3092\u6291\u5236\u3059\u308b\u305f\u3081\u306b\u7528\u3044\u3089\u308c\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>pro<\/i>AB<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u6700\u5c11\u57f9\u5730\u306b\u30d7\u30ed\u30ea\u30f3\u306e\u6dfb\u52a0\u304c\u5fc5\u8981\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>rec<\/i>A<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">DNA\u306e\u4e00\u822c\u7684\u306a\u7d44\u63db\u3048\u306b\u95a2\u4e0e\u3059\u308b\u907a\u4f1d\u5b50\u306e\u5909\u7570\u3002\u5c0e\u5165DNA\u3068\u5bbf\u4e3bDNA\u3068\u306e\u7d44\u63db\u3048\u3092\u9632\u3050\u3002\u7279\u306b\u30c0\u30a4\u30ec\u30af\u30c8\u30ea\u30d4\u30fc\u30c8\u3092\u6709\u3059\u308b\u907a\u4f1d\u5b50\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u306b\u6709\u7528\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>rel<\/i>A<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30bf\u30f3\u30d1\u30af\u8cea\u5408\u6210\u304c\u884c\u308f\u308c\u305a\u306bRNA\u304c\u5408\u6210\u3055\u308c\u308b(\u5f1b\u7de9\u8868\u73fe\u578b)\u3002<i>rel<\/i>A\u907a\u4f1d\u5b50\u5ea7\u306f\u8ee2\u5199\u3068\u7ffb\u8a33\u9593\u306e\u30ab\u30c3\u30d7\u30ea\u30f3\u30b0\u3092\u8abf\u7bc0\u3059\u308b\u3002\u91ce\u751f\u578b\u3067\u306f\u30a2\u30df\u30ce\u9178\u6fc3\u5ea6\u304c\u5236\u9650\u3055\u308c\u308b\u3068RNA\u5408\u6210\u304c\u505c\u6b62\u3059\u308b(\u7dca\u7e2e\u5fdc\u7b54\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u308b)\u3002<i>rel<\/i>A\u682a(\u5f1b\u7de9\u5fdc\u7b54)\u3067\u306f\u30a2\u30df\u30ce\u9178\u6fc3\u5ea6\u304c\u5236\u9650\u3055\u308c\u3066\u3044\u3066\u3082RNA\u306e\u5408\u6210\u304c\u7d99\u7d9a\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>rsp<\/i>L<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">30S \u30ea\u30dc\u30bd\u30fc\u30e0\u306eS12 \u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u306e\u5909\u7570\u3002\u30b9\u30c8\u30ec\u30d7\u30c8\u30de\u30a4\u30b7\u30f3\u306b\u5bfe\u3059\u308b\u8010\u6027\u304c\u5f97\u3089\u308c\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>sup<\/i>E,F<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30a2\u30f3\u30d0\u30fc(<i>sup<\/i>E)(UAG)\u307e\u305f\u306f\u30c1\u30ed\u30b7\u30f3(<i>sup<\/i>F)\u306etRNA\u30b0\u30eb\u30bf\u30df\u30f3\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u3002<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>thi<\/i>-1<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u6700\u5c11\u57f9\u5730\u306b\u30c1\u30a2\u30df\u30f3\u306e\u6dfb\u52a0\u3092\u8981\u6c42\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Tn10<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30c8\u30e9\u30f3\u30b9\u30dd\u30be\u30f3\u3092\u4ecb\u3057\u305f\u30c6\u30c8\u30e9\u30b5\u30a4\u30af\u30ea\u30f3\u8010\u6027<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>ton<\/i>A<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u6eb6\u83cc\u6027\u30d0\u30af\u30c6\u30ea\u30aa\u30d5\u30a1\u30fc\u30b8\u306eT1\u3001T5\u304a\u3088\u3073\u03c680\u306b\u5bfe\u3059\u308b\u8010\u6027\u3092\u4ed8\u4e0e\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>tra<\/i>D, D36<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u8ee2\u79fb\u56e0\u5b50\u306e\u5909\u7570\u306b\u3088\u308aF&#8217;\u30a8\u30d4\u30bd\u30fc\u30e0\u306e\u8ee2\u79fb\u3092\u59a8\u3052\u308b<\/td>\n<\/tr>\n<tr class=\"alt\">\n<td valign=\"top\"><i>tsx<\/i><\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">T6\u30d5\u30a1\u30fc\u30b8\u304a\u3088\u3073\u30b3\u30ea\u30b7\u30f3K\u306b\u5bfe\u3059\u308b\u8010\u6027\u3092\u4ed8\u4e0e\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><i>xyl<\/i>-5<\/td>\n<td width=\"10\"><\/td>\n<td valign=\"top\">\u30ad\u30b7\u30ed\u30fc\u30b9\u306e\u4ee3\u8b1d\u306e\u963b\u5bb3\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 8pt\">(1) <i>Eco<\/i>KI\u8a8d\u8b58\u90e8\u4f4d: CC(N<sub>6<\/sub>)GTGC \u3082\u3057\u304f\u306f GCAC(N<sub>6<\/sub>)GTT<\/span><br \/>\n<span style=\"font-size: 8pt\">(2) <i>Eco<\/i>B\u8a8d\u8b58\u90e8\u4f4d: TGA(N<sub>8<\/sub>)TGCT<\/span><\/p>\n<h2>\u304a\u308f\u308a\u306b<\/h2>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u81ea\u5206\u306e\u5b9f\u9a13\u76ee\u7684\u306b\u5408\u3063\u305f\u5927\u8178\u83cc\u3092\u63a2\u3059\u3068\u304d\u3001\u4eca\u56de\u7d39\u4ecb\u3057\u305f\u907a\u4f1d\u5b50\u578b\u306e\u4e00\u89a7\u304c\u53c2\u8003\u306b\u306a\u308b\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u3088\u304f\u5206\u304b\u3089\u306a\u3044\u907a\u4f1d\u5b50\u578b\u3092\u898b\u305f\u3068\u304d\u306f\u305c\u3072\u3053\u306e\u8a18\u4e8b\u3092\u601d\u3044\u51fa\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n<h2>\u3053\u308c\u3060\u3051\u306f\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u306e\u57fa\u790e\u77e5\u8b58\u3001\u30b3\u30b3\u306b\u3042\u308a\u307e\u3059\uff01<\/h2>\n<p>Invitrogen \u5206\u5b50\u751f\u7269\u5b66\u6559\u5ba4\u3067\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u6559\u80b2\u306e\u30e1\u30a4\u30f3\u3068\u3057\u3066\u3001\u521d\u5fc3\u8005\u3060\u3051\u3067\u306a\u304f\u7d4c\u9a13\u306e\u3042\u308b\u5206\u5b50\u751f\u7269\u5b66\u8005\u306e\u305f\u3081\u306b\u3001\u8c4a\u5bcc\u3067\u4fe1\u983c\u3067\u304d\u308b\u6280\u8853\u7684\u306a\u5185\u5bb9\u3092\u3054\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u57fa\u790e\u77e5\u8b58\u3092\u5b66\u3076\u6642\u306b\u306f\u3044\u3064\u3067\u3082\u3001Invitrogen \u5206\u5b50\u751f\u7269\u5b66\u6559\u5ba4\u306e\u7121\u6599PDF\u3092\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/mol-bio-school.html?CID=bid_mol_clo_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_mb5_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d1\u30c3\u3068\u898b\u3067\u3069\u3093\u306a\u6a5f\u80fd\u304c\u6b20\u640d\u3057\u3066\u3044\u308b\u306e\u304b\u3088\u304f\u5206\u304b\u3089\u306a\u3044\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u3002\u4eca\u56de\u3054\u7d39\u4ecb\u3059\u308b\u4e00\u89a7\u3092\u898b\u308c\u3070\u4e00\u767a\u3067\u5206\u304b\u308a\u307e\u3059\uff01<\/p>\n","protected":false},"author":988,"featured_media":2156,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[14,26],"division":[],"class_list":{"0":"post-114","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-cloning","9":"tag-genotyping","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u30d1\u30c3\u3068\u898b\u3067\u3069\u3093\u306a\u6a5f\u80fd\u304c\u6b20\u640d\u3057\u3066\u3044\u308b\u306e\u304b\u3088\u304f\u5206\u304b\u3089\u306a\u3044\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u3002\u4eca\u56de\u3054\u7d39\u4ecb\u3059\u308b\u4e00\u89a7\u3092\u898b\u308c\u3070\u4e00\u767a\u3067\u5206\u304b\u308a\u307e\u3059\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2015-10-15T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-27T02:40:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"15\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081\",\"datePublished\":\"2015-10-15T00:00:00+00:00\",\"dateModified\":\"2024-08-27T02:40:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/\"},\"wordCount\":600,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ecoli-genotype-title-1.jpg\",\"keywords\":[\"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\",\"\u907a\u4f1d\u5b50\u578b\u6c7a\u5b9a\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/\",\"name\":\"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ecoli-genotype-title-1.jpg\",\"datePublished\":\"2015-10-15T00:00:00+00:00\",\"dateModified\":\"2024-08-27T02:40:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ecoli-genotype-title-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/ecoli-genotype-title-1.jpg\",\"width\":1200,\"height\":630,\"caption\":\"ecoli-genotype-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ecoli-genotype\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/","og_locale":"ja_JP","og_type":"article","og_title":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081","og_description":"\u30d1\u30c3\u3068\u898b\u3067\u3069\u3093\u306a\u6a5f\u80fd\u304c\u6b20\u640d\u3057\u3066\u3044\u308b\u306e\u304b\u3088\u304f\u5206\u304b\u3089\u306a\u3044\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u3002\u4eca\u56de\u3054\u7d39\u4ecb\u3059\u308b\u4e00\u89a7\u3092\u898b\u308c\u3070\u4e00\u767a\u3067\u5206\u304b\u308a\u307e\u3059\uff01","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2015-10-15T00:00:00+00:00","article_modified_time":"2024-08-27T02:40:28+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"15\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081","datePublished":"2015-10-15T00:00:00+00:00","dateModified":"2024-08-27T02:40:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/"},"wordCount":600,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","keywords":["\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","\u907a\u4f1d\u5b50\u578b\u6c7a\u5b9a"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/","name":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","datePublished":"2015-10-15T00:00:00+00:00","dateModified":"2024-08-27T02:40:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","width":1200,"height":630,"caption":"ecoli-genotype-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ecoli-genotype\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"endA\u3063\u3066\u3069\u3046\u3044\u3046\u610f\u5473\uff1f\u77e5\u3063\u3066\u304a\u304f\u3068\u5f79\u7acb\u3064\u4e3b\u306a\u5927\u8178\u83cc\u306e\u907a\u4f1d\u5b50\u578b\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":14,"label":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0"},{"value":26,"label":"\u907a\u4f1d\u5b50\u578b\u6c7a\u5b9a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":537,"filter":"raw","meta":[],"cat_ID":156,"category_count":537,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":14,"name":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","slug":"cloning","term_group":0,"term_taxonomy_id":14,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":26,"name":"\u907a\u4f1d\u5b50\u578b\u6c7a\u5b9a","slug":"genotyping","term_group":0,"term_taxonomy_id":26,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":114,"position":0},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24968,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-protein-expression-bid-ts-mbr-26012_\/","url_meta":{"origin":114,"position":1},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046","author":"LatB Staff","date":"2026\u5e743\u670816\u65e5","format":false,"excerpt":"\u5206\u5b50\u751f\u7269\u5b66\u306e\u9ece\u660e\u671f\u3092\u652f\u3048\u3066\u304d\u305f\u5927\u8178\u83cc\uff08Escherichia coli\uff09\u3067\u3059\u304c\u3001\u8fd1\u5e74\u3067\u306f\u5168\u304f\u6271\u308f\u306a\u3044\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":114,"position":2},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":114,"position":3},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":114,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24122,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-therapy-purification-affinity-chromatography-bpg-25072\/","url_meta":{"origin":114,"position":5},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u907a\u4f1d\u5b50\u6cbb\u7642\u306b\u304a\u3051\u308b\u7cbe\u88fd\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670826\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u907a\u4f1d\u5b50\u6cbb\u7642\u306e\u6025\u901f\u306a\u767a\u5c55\u306b\u3088\u308a\u3001\u6cbb\u7642\u6cd5\u306e\u958b\u767a\u3068\u5b9f\u7528\u5316\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u304c\u6d3b\u767a\u5316\u3057\u3066\u3044\u307e\u3059\u3002 \u672c\u30d6\u30ed\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-bpg-25072_eycatch.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/ecoli-genotype-title-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=114"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/114\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2156"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=114"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}