{"id":11540,"date":"2022-06-17T11:43:00","date_gmt":"2022-06-17T02:43:00","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=11540"},"modified":"2022-06-17T11:43:00","modified_gmt":"2022-06-17T02:43:00","slug":"foreign_material_ft-ir_msd_sales_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/","title":{"rendered":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd"},"content":{"rendered":"<p>FT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u306f\u591a\u304f\u306e\u6709\u6a5f\u6750\u6599\u3084\u88fd\u54c1\u4e2d\u306e\u7570\u7269\u3001\u4e0d\u7d14\u7269\u306e\u5b9a\u6027\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u88fd\u54c1\u306e\u4e00\u3064\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u7269\u304c\u5358\u7d14\uff08\u5358\u4e00\uff09\u306a\u6210\u5206\u3067\u3042\u308c\u3070\u3001ATR\u6e2c\u5b9a\u3068\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u7528\u3044\u305f\u691c\u7d22\u6a5f\u80fd\u306b\u3088\u308a\u308f\u305a\u304b\u6570\u5341\u79d2\u3067\u7269\u8cea\u306e\u7279\u5b9a\u306b\u81f3\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u8907\u6570\u6210\u5206\u304c\u542b\u307e\u308c\u308b\u3001\u3044\u308f\u3086\u308b\u6df7\u5408\u7269\uff08\u4e3b\u6210\u5206\u3001\u6dfb\u52a0\u5264\u3001\u6c5a\u67d3\u7269\u8cea\u306a\u3069\uff09\u3067\u3042\u308b\u3082\u306e\u304c\u307b\u3068\u3093\u3069\u3067\u3042\u308a\u3001\u305d\u306e\u5834\u5408\u306f\u3053\u308c\u3089\u3092\u305d\u308c\u305e\u308c\u5b9a\u6027\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u306f\u7d4c\u9a13\u3068\u77e5\u8b58\u3092\u8981\u3057\u307e\u3059\u3002<\/p>\n<p>\u5f53\u793eFT-IR\u88fd\u54c1\u306b\u4ed8\u5c5e\u3059\u308bThermo Scientific\u2122 OMNIC\u2122 Specta\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u591a\u6210\u5206\u30b5\u30fc\u30c1\u691c\u7d22\u3001\u4e0d\u7d14\u7269\u30b5\u30fc\u30c1\u6a5f\u80fd\u3092\u6709\u3057\u3001\u3053\u306e\u3088\u3046\u306a\u6df7\u5408\u7269\u306e\u89e3\u6790\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u30d1\u30ef\u30d5\u30eb\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001OMNIC Specta\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u305f\u6df7\u5408\u7269\u306b\u542b\u307e\u308c\u308b\u7269\u8cea\u306e\u7279\u5b9a\u4f8b\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fbFT-IR\u306b\u3088\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u80fd\u529b\u3092\u5f37\u5316\u3057\u305f\u3044<br \/>\n\u30fb\u30e9\u30dc\u306e\u7570\u7269\u89e3\u6790\u306e\u80fd\u529b\u3092\u5411\u4e0a\u3057\u305f\u3044<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg\" alt=\"\" width=\"359\" height=\"305\" class=\"aligncenter size-full wp-image-11572\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg 359w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori-300x255.jpg 300w\" sizes=\"auto, (max-width: 359px) 100vw, 359px\" \/><\/p>\n<h2>\u6df7\u5408\u7269\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306e\u89e3\u91c8\u3068\u624b\u9806<\/h2>\n<p>\u901a\u5e38\u3001\u6df7\u5408\u7269\u306e\u5b9a\u6027\u306b\u306f\u30b9\u30da\u30af\u30c8\u30eb\u306e\u89e3\u91c8\u304a\u3088\u3073\u591a\u6bb5\u968e\u306e\u5b9a\u6027\u624b\u9806\u306e\u69cb\u7bc9\u304c\u5fc5\u8981\u3067\u3001\u3053\u308c\u3089\u3092\u884c\u3046\u305f\u3081\u306b\u306f\u591a\u304f\u306e\u7d4c\u9a13\u3068\u77e5\u8b58\u3092\u8981\u3057\u307e\u3059\u3002\u6df7\u5408\u7269\u306e\u5b9a\u6027\u3067\u306f\u3001\u307e\u305a\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u304b\u3089\u9069\u5207\u306a\u6ce2\u6570\u7bc4\u56f2\u3092\u9078\u629e\u3057\u3066\u300c\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u300d\u3092\u884c\u3044\u3001\u6b21\u306b\u6df7\u5408\u7269\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u3068\u5f97\u3089\u308c\u305f\u691c\u7d22\u7d50\u679c\u306e\u30b9\u30da\u30af\u30c8\u30eb\u3067\u300c\u5f15\u304d\u7b97\u300d\uff08\u5dee\u30b9\u30da\u30af\u30c8\u30eb\u51e6\u7406\uff09\u3092\u884c\u3044\u3001\u5f97\u3089\u308c\u305f\u5dee\u30b9\u30da\u30af\u30c8\u30eb\u7d50\u679c\u306b\u3064\u3044\u3066\u518d\u3073\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u3092\u884c\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u9806\u3092\u7e70\u308a\u8fd4\u3057\u884c\u3046\u3053\u3068\u3067\u3001\u6df7\u5408\u7269\u306b\u542b\u307e\u308c\u308b\u7b2c\u4e8c\u3001\u7b2c\u4e09\u306e\u6210\u5206\u3092\u7279\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u624b\u9806\u306fFT-IR\u3092\u7528\u3044\u305f\u6df7\u5408\u7269\u306e\u5b9a\u6027\u624b\u6bb5\u3068\u3057\u3066\u4e00\u822c\u7684\u306a\u3082\u306e\u306e\u3001\u3044\u304f\u3064\u304b\u306e\u554f\u984c\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u3064\u76ee\u306f\u3001\u5206\u6790\u8005\u304c\u6700\u521d\u306e\u300c\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u300d\u304b\u3089\u5f97\u3089\u308c\u305f\u7d50\u679c\u306e\u4e2d\u304b\u3089\u9069\u5207\u306a\u30b9\u30da\u30af\u30c8\u30eb\u3092\u9078\u629e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u3067\u3059\u3002\u6df7\u5408\u7269\u306e\u5b9a\u6027\u3067\u306f\u3001\u5b9f\u969b\u306b\u6e2c\u5b9a\u3057\u305f\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u542b\u307e\u308c\u308b\u6b63\u3057\u3044\u691c\u7d22\u7d50\u679c\u304c\u6700\u4e0a\u4f4d\u306b\u73fe\u308c\u306a\u3044\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001\u691c\u7d22\u7d50\u679c\u30ea\u30b9\u30c8\uff08\u5019\u88dc\u30ea\u30b9\u30c8\uff09\u306e\u4e2d\u304b\u3089\u6df7\u5408\u7269\u306b\u542b\u307e\u308c\u308b\u3067\u3042\u308d\u3046\u7269\u8cea\u3092\u9078\u629e\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u307e\u305f\u5dee\u30b9\u30da\u30af\u30c8\u30eb\u306e\u51e6\u7406\u306b\u306f\u7d4c\u9a13\u3092\u6709\u3059\u308b\u3053\u3068\u304c\u3057\u3070\u3057\u3070\u3067\u3001\u305d\u306e\u7d50\u679c\u3001\u6df7\u5408\u6210\u5206\u3092\u53d6\u308a\u9664\u3051\u3066\u3044\u306a\u3044\u3001\u3042\u308b\u3044\u306f\u9593\u9055\u3063\u305f\u5dee\u30b9\u30da\u30af\u30c8\u30eb\u7d50\u679c\u3092\u7528\u3044\u3066\u3001\u518d\u89e3\u6790\u3092\u5b9f\u65bd\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u3053\u308c\u304c\u8aa4\u89e3\u6790\u306e\u8981\u56e0\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>OMNIC Specta \u300c\u591a\u6210\u5206\u30b5\u30fc\u30c1\u300d\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u5fdc\u7528\u4f8b<\/h2>\n<p>Thermo Scientific OMNIC Specta\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u65b0\u305f\u306a\u6df7\u5408\u7269\u306e\u5206\u6790\u624b\u6cd5\u3092\u63d0\u4f9b\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u3059\u3002\u901a\u5e38\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u3067\u306f\u691c\u7d22\u5bfe\u8c61\u306b\u4f3c\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u30b9\u30da\u30af\u30c8\u30eb\u3092\u8868\u793a\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u3057OMNIC Specta\u306e\u300c\u591a\u6210\u5206\u30b5\u30fc\u30c1\u300d\u6a5f\u80fd\u3067\u306f\u3001\u5206\u6790\u8005\u304c\u9078\u629e\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u304b\u3089\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304c2\uff5e4\u672c\u306e\u6700\u9069\u306a\u30b9\u30da\u30af\u30c8\u30eb\u3092\u62bd\u51fa\u3057\u3001\u3053\u308c\u3089\u3092\u4efb\u610f\u306e\u5272\u5408\u3067\u8db3\u3057\u5408\u308f\u305b\u305f\u5408\u6210\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u3092\u4f5c\u6210\u3057\u3066\u691c\u7d22\u7d50\u679c\u3068\u3057\u3066\u8868\u793a\u3057\u307e\u3059\u3002<\/p>\n<p>\u5177\u4f53\u4f8b\u306f\u4e0b\u56f3\u306e\u901a\u308a\u3067\u3059\u3002\u3042\u308b\u88fd\u54c1\u304b\u3089\u767a\u751f\u3057\u305f\u7570\u7269\u3092\u30c0\u30a4\u30e4\u30e2\u30f3\u30c9ATR\u3067\u6e2c\u5b9a\u3057\u3001\u5f97\u3089\u308c\u305f\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3064\u3044\u3066\u591a\u6210\u5206\u30b5\u30fc\u30c1\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u3053\u306e\u691c\u7d22\u306b\u3088\u308a\u3001\u7570\u7269\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u306f\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\uff08\u53ef\u5851\u5264\uff09\u3001\u70ad\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\uff08\u5145\u586b\u6750\uff09\u3001\u30dd\u30ea\u5869\u5316\u30d3\u30cb\u30fc\u30eb\uff08\u57fa\u6750\uff09\u304c\u542b\u307e\u308c\u308b\u3053\u3068\u3092\u793a\u3059\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u70ad\u9178\u30ab\u30eb\u30b7\u30a6\u30e0\u306f\u3001\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u3068\u540c\u69d8\u306b\u7570\u7269\u3068\u3057\u3066\u542b\u307e\u308c\u3066\u3044\u308b\u6210\u5206\u306e\u4e00\u3064\u3067\u3059\u304c\u3001\u901a\u5e38\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u691c\u7d22\u3067\u306f\u898b\u843d\u3068\u3059\u3053\u3068\u304c\u307b\u3068\u3093\u3069\u3067\u3059\u3002\u3053\u306e\u7d50\u679c\u306b\u304a\u3044\u3066\u3001\u3053\u306e\u7570\u7269\u306e\u30b9\u30da\u30af\u30c8\u30eb\u306b\u306f3\u3064\u306e\u6210\u5206\u304c\u6df7\u5408\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/OMNIC1.jpg\" alt=\"OMNIC Specta\" width=\"731\" height=\"920\" class=\"aligncenter size-full wp-image-11541\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/OMNIC1.jpg 731w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/OMNIC1-238x300.jpg 238w\" sizes=\"auto, (max-width: 731px) 100vw, 731px\" \/><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3053\u306e\u3088\u3046\u306b\u3001OMNIC Specta\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u591a\u6210\u5206\u30b5\u30fc\u30c1\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u8fc5\u901f\u304b\u3064\u5bb9\u6613\u306b\u6df7\u5408\u7269\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306e\u5b9a\u6027\u5206\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u7279\u5225\u306a\u77e5\u8b58\u3092\u8981\u305b\u305a\u4fe1\u983c\u3067\u304d\u308b\u89e3\u6790\u7d50\u679c\u3092\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u65e5\u3005\u5206\u6790\u3092\u884c\u3063\u3066\u3044\u308b\u65b9\u3060\u3051\u3067\u306a\u304f\u3001\u666e\u6bb5FT-IR\u306b\u3088\u308b\u5206\u6790\u3092\u884c\u3063\u3066\u3044\u306a\u3044\u65b9\u306b\u3082\u3054\u4f7f\u7528\u3044\u305f\u3060\u3051\u308b\u3001\u975e\u5e38\u306b\u4fbf\u5229\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002<\/p>\n<p>\u672c\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u95a2\u3057\u3066\u3088\u308a\u8a73\u3057\u3044\u5185\u5bb9\u306f\u4e0b\u8a18\u306b\u3066\u7d39\u4ecb\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/an-086-ftir-mixture-library-search-an086-ja.pdf\" rel=\"noopener\" target=\"_blank\">OMNIC Specta\u306b\u3088\u308b\u6df7\u5408\u7269\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30b5\u30fc\u30c1 (thermofisher.com)<\/a><\/p>\n<p><strong>FT-IR\u88fd\u54c1\u306b\u3064\u3044\u3066\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u3092\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/strong><br \/>\n\u30c7\u30e2\u3084\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3054\u5e0c\u671b\u306e\u65b9\u3082\u4e0b\u8a18\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/spectroscopy-materials-analysis-inquiries.html?cid=foreign_material_ft-ir_msd_sales_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>FT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u306f\u591a\u304f\u306e\u6709\u6a5f\u6750\u6599\u3084\u88fd\u54c1\u4e2d\u306e\u7570\u7269\u3001\u4e0d\u7d14\u7269\u306e\u5b9a\u6027\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u88fd\u54c1\u306e\u4e00\u3064\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u7269\u304c\u5358\u7d14\uff08\u5358\u4e00\uff09\u306a\u6210\u5206\u3067\u3042\u308c\u3070\u3001ATR\u6e2c\u5b9a\u3068\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u7528\u3044\u305f\u691c\u7d22\u6a5f\u80fd\u306b\u3088\u308a\u308f\u305a\u304b\u6570\u5341<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[],"division":[],"class_list":{"0":"post-11540","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-else","7":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd\" \/>\n<meta property=\"og:description\" content=\"FT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u306f\u591a\u304f\u306e\u6709\u6a5f\u6750\u6599\u3084\u88fd\u54c1\u4e2d\u306e\u7570\u7269\u3001\u4e0d\u7d14\u7269\u306e\u5b9a\u6027\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u88fd\u54c1\u306e\u4e00\u3064\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u7269\u304c\u5358\u7d14\uff08\u5358\u4e00\uff09\u306a\u6210\u5206\u3067\u3042\u308c\u3070\u3001ATR\u6e2c\u5b9a\u3068\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u7528\u3044\u305f\u691c\u7d22\u6a5f\u80fd\u306b\u3088\u308a\u308f\u305a\u304b\u6570\u5341\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-17T02:43:00+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd\",\"datePublished\":\"2022-06-17T02:43:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/\"},\"wordCount\":29,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/FTIR_Hattori.jpg\",\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/\",\"name\":\"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/FTIR_Hattori.jpg\",\"datePublished\":\"2022-06-17T02:43:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/FTIR_Hattori.jpg\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/FTIR_Hattori.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd","og_description":"FT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u306f\u591a\u304f\u306e\u6709\u6a5f\u6750\u6599\u3084\u88fd\u54c1\u4e2d\u306e\u7570\u7269\u3001\u4e0d\u7d14\u7269\u306e\u5b9a\u6027\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u88fd\u54c1\u306e\u4e00\u3064\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u7269\u304c\u5358\u7d14\uff08\u5358\u4e00\uff09\u306a\u6210\u5206\u3067\u3042\u308c\u3070\u3001ATR\u6e2c\u5b9a\u3068\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u7528\u3044\u305f\u691c\u7d22\u6a5f\u80fd\u306b\u3088\u308a\u308f\u305a\u304b\u6570\u5341","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-06-17T02:43:00+00:00","og_image":[{"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg","type":"","width":"","height":""}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd","datePublished":"2022-06-17T02:43:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/"},"wordCount":29,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg","articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/","name":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg","datePublished":"2022-06-17T02:43:00+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/FTIR_Hattori.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u88fd\u54c1\u7570\u7269\u89e3\u6790\u306e\u554f\u984c\u3092\u89e3\u6c7a\uff01\u591a\u6210\u5206\u30b5\u30fc\u30c1\u6a5f\u80fd"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":11540,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":11540,"position":1},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":11540,"position":2},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":11540,"position":3},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":11540,"position":4},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":11540,"position":5},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=11540"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11540\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=11540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=11540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=11540"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=11540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}