{"id":117,"date":"2020-03-04T00:00:00","date_gmt":"2020-03-03T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/"},"modified":"2025-07-24T19:23:49","modified_gmt":"2025-07-24T10:23:49","slug":"protein-basic10","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/","title":{"rendered":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de"},"content":{"rendered":"<p>\u7b2c10\u56de\u76ee\u306e\u4eca\u56de\u306f\u3001\u514d\u75ab\u691c\u51fa\u3001\u7279\u5b9a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3001\u7d30\u80de\u5206\u96e2\u3068\u3044\u3063\u305f\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u5e83\u304f\u5229\u7528\u3055\u308c\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01<\/p>\n<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u751f\u5375\u767d\u3092\u904e\u5270\u306b\u6442\u53d6\u3059\u308b\u3068\u5065\u5eb7\u969c\u5bb3\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u304b\u308970\u5e74\u4ee5\u4e0a\u524d\u3001\u3053\u306e\u904e\u5270\u6442\u53d6\u306b\u95a2\u3059\u308b\u7814\u7a76\u306e\u4e2d\u3067\u3001\u65b0\u305f\u306a\u30d3\u30bf\u30df\u30f3\u3067\u3042\u308b\u30d3\u30bf\u30df\u30f3H \uff08\u30d3\u30bf\u30df\u30f3B7\uff09\u3068\u3057\u3066\u30d3\u30aa\u30c1\u30f3\u304c\u767a\u898b\u3055\u308c\u307e\u3057\u305f\u3002\u7d9a\u3044\u3066\u3001\u3053\u306e\u30d3\u30aa\u30c1\u30f3\u3068\u306e\u7d50\u5408\u306b\u3088\u308a\u904e\u5270\u6442\u53d6\u969c\u5bb3\u306e\u539f\u56e0\u3068\u306a\u308b\u5375\u767d\u4e2d\u306e\u6210\u5206\u304c\u30a2\u30d3\u30b8\u30f3\u3067\u3042\u308b\u3053\u3068\u304c\u767a\u898b\u3055\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u3053\u306e\u30d3\u30aa\u30c1\u30f3\u3068\u30a2\u30d3\u30b8\u30f3\u3068\u306e\u7d50\u5408\u304c\u3001\u975e\u5171\u6709\u7d50\u5408\u3067\u3042\u308a\u306a\u304c\u3089\u975e\u5e38\u306b\u5f37\u3044\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u30d3\u30aa\u30c1\u30f3\u306e\u30d0\u30ec\u30ea\u30a2\u30f3\u9178\u5074\u9396\uff08\u56f31\u53c2\u7167\uff09\u306b\u306f\u3001\u8a98\u5c0e\u4f53\u5316\u306b\u3088\u3063\u3066\u3055\u307e\u3056\u307e\u306a\u6a19\u8b58\u5b98\u80fd\u57fa\u3092\u6bd4\u8f03\u7684\u5bb9\u6613\u306b\u5c0e\u5165\u3067\u304d\u308b\u3053\u3068\u304b\u3089\u3001\u751f\u4f53\u5206\u5b50\u3078\u306e\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u3082\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\u3002<strong>\u30d3\u30aa\u30c1\u30f3\u304c\u4f4e\u5206\u5b50\uff08MW 244.3\uff09\u3067\u3042\u308b\u305f\u3081\u6a19\u8b58\u5206\u5b50\u3078\u306e\u5f71\u97ff\u3082\u5c11\u306a\u304f\u3001\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u9593\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u304c\u9ad8\u3044\u3053\u3068\u304b\u3089\u3001\u514d\u75ab\u691c\u51fa\u3001\u7279\u5b9a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3001\u7d30\u80de\u5206\u96e2\u3068\u3044\u3063\u305f\u3055\u307e\u3056\u307e\u306a\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u5229\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002<\/strong><\/p>\n<div id=\"attachment_367\" style=\"width: 410px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic10-fig1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-367\" class=\"size-full wp-image-367\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic10-fig1.jpg\" alt=\"protein-basic10-fig1\" width=\"400\" height=\"210\" \/><\/a><p id=\"caption-attachment-367\" class=\"wp-caption-text\">\u56f31 \u30d3\u30aa\u30c1\u30f3\u306e\u69cb\u9020<\/p><\/div>\n<p>\u4ee5\u4e0b\u3067\u306f\u3001\u4ee3\u8868\u7684\u306a\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7279\u6027\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6bd4\u8f03<\/h2>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td><strong>\u30a2\u30d3\u30b8\u30f3<\/strong><\/td>\n<td><strong>\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3<\/strong><\/td>\n<td><strong>\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u5206\u5b50\u91cf<\/strong><\/td>\n<td>67 kDa<\/td>\n<td>53 kDa<\/td>\n<td>60 kDa<\/td>\n<\/tr>\n<tr>\n<td><strong>\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30b5\u30a4\u30c8\u306e\u6570<\/strong><\/td>\n<td>4<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7b49\u96fb\u70b9\uff08pI\uff09<\/strong><\/td>\n<td>10<\/td>\n<td>6.8 ~ 7.5<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td><strong>\u7279\u7570\u6027<\/strong><\/td>\n<td>\u4f4e\u3044<\/td>\n<td>\u9ad8\u3044<\/td>\n<td>\u3088\u308a\u9ad8\u3044<\/td>\n<\/tr>\n<tr>\n<td><strong>\u30d3\u30aa\u30c1\u30f3\u3068\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\uff08Kd\uff09<\/strong><\/td>\n<td>10<sup>-15<\/sup>M<\/td>\n<td>10<sup>-15<\/sup>M<\/td>\n<td>10<sup>-15<\/sup>M<\/td>\n<\/tr>\n<tr>\n<td><strong>\u975e\u7279\u7570\u7684\u7d50\u5408<\/strong><\/td>\n<td>\u9ad8\u3044<\/td>\n<td>\u4f4e\u3044<\/td>\n<td>\u3088\u308a\u4f4e\u3044<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u30a2\u30d3\u30b8\u30f3<\/h3>\n<p>\u30a2\u30d3\u30b8\u30f3\u306f\u3001\u5206\u5b50\u91cf67,000-68,000 Da\u306e\u7cd6\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3059\u3002\u5375\u767d\u3060\u3051\u3067\u306a\u304f\u3001\u9ce5\u3001\u306f\u866b\u985e\u3001\u4e21\u751f\u985e\u306e\u7d44\u7e54\u306b\u3082\u5b58\u5728\u3057\u307e\u3059\u3002128\u30a2\u30df\u30ce\u9178\u304b\u3089\u306a\u308b\u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u304c4\u91cf\u4f53\u3092\u5f62\u6210\u3057\u3066\u304a\u308a\u3001\u5404\u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u304c1\u5206\u5b50\u306e\u30d3\u30aa\u30c1\u30f3\u3068\u7d50\u5408\u3059\u308b\u305f\u3081\u3001\u6700\u59274\u5206\u5b50\u306e\u30d3\u30aa\u30c1\u30f3\u3068\u7d50\u5408\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u30a2\u30d3\u30b8\u30f3\u306f\u514d\u75ab\u691c\u51fa\u306b\u304a\u3051\u308b\u30b7\u30b0\u30ca\u30eb\u5897\u5e45\u306b\u3082\u5229\u7528\u3055\u308c\u307e\u3059\uff08ABC\u6cd5: Avidin-Biotin-Complex\u6cd5\uff09\u3002\u30a2\u30d3\u30b8\u30f3\u306f\u6bd4\u8f03\u7684\u5e45\u5e83\u3044pH\u4e0b\u3067\u3082\u5b89\u5b9a\u3067\u3001\u7b49\u96fb\u70b9\uff08pI\uff09\u306f10-10.5\u4ed8\u8fd1\u306b\u3042\u308a\u307e\u3059\u3002\u30a2\u30d3\u30b8\u30f3\u306f\u3001<strong>\u7cd6\u9396\u304c\u591a\u304f\uff08\u5168\u8cea\u91cf\u306e10%\u7a0b\u5ea6\uff09\u3001pI\u304c\u9ad8\u3044\u305f\u3081\u3001\u975e\u7279\u7570\u7684\u306a\u7d50\u5408\u3092\u8d77\u3053\u3057\u3084\u3059\u3044\u3068\u3044\u3046\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u3002<\/strong><\/p>\n<h3>\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3<\/h3>\n<p>\u30a2\u30d3\u30b8\u30f3\u306e\u30a2\u30ca\u30ed\u30b0\u3067\u3042\u308b\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3\u306f\u3001<em>Streptomyces avidinii<\/em>\u304b\u3089\u5358\u96e2\u3055\u308c\u308b\u5206\u5b50\u91cf75,000 Da\u306e\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3001\u7b49\u96fb\u70b9\u306f\u9178\u6027\uff08pI = 5.5\uff09\u5074\u306b\u3042\u308a\u307e\u3059\u3002\u7d44\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u5408\u6210\u3055\u308c\u3066\u3044\u308b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/434301?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa20_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Streptavidin<\/a>\u306e\u5834\u5408\u3001\u5206\u5b50\u91cf53,000 Da\u3067\u7b49\u96fb\u70b9\u306f\u4e2d\u6027\u4ed8\u8fd1\u306b\u3042\u308a\u307e\u3059\u3002\u30a2\u30d3\u30b8\u30f3\u3068\u540c\u69d8\u3001\u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u304c4\u91cf\u4f53\u3092\u5f62\u6210\u3057\u3066\u304a\u308a\u3001\u6700\u59274\u5206\u5b50\u306e\u30d3\u30aa\u30c1\u30f3\u3068\u7d50\u5408\u3067\u304d\u3001\u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u540c\u58eb\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u306f\u30a2\u30d3\u30b8\u30f3\u3088\u308a\u9ad8\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3\u306f\u3001\u7cd6\u9396\u4fee\u98fe\u3092\u53d7\u3051\u3066\u304a\u3089\u305a\u3001\u6c34\u3078\u306e\u6eb6\u89e3\u6027\u306f\u30a2\u30d3\u30b8\u30f3\u306b\u6bd4\u3079\u3066\u4f4e\u304f\u306a\u308a\u307e\u3059\u304c\u3001<strong>\u30a2\u30d3\u30b8\u30f3\u306b\u6bd4\u3079\u3066\u975e\u7279\u7570\u7684\u306a\u7d50\u5408\u304c\u8d77\u304d\u306b\u304f\u304f\u306a\u308a\u307e\u3059\u3002<\/strong>\u305f\u3060\u3057\u3001\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3\u306b\u306fRYD\uff08\u30a2\u30eb\u30ae\u30cb\u30f3-\u30c1\u30ed\u30b7\u30f3-\u30a2\u30b9\u30d1\u30e9\u30ae\u30f3\u9178\uff09\u914d\u5217\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u7d30\u80de\u3092\u5229\u7528\u3059\u308b\u5b9f\u9a13\u7cfb\u3067\u306f\u7279\u306b\u3001\u3053\u306e\u914d\u5217\u304c\u539f\u56e0\u3067\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u4e0a\u6607\u3059\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002RGD\uff08\u30a2\u30eb\u30ae\u30cb\u30f3-\u30b0\u30ea\u30b7\u30f3-\u30a2\u30b9\u30d1\u30e9\u30ae\u30f3\u9178\uff09\u914d\u5217\u306b\u4f3c\u3066\u3044\u308bRYD\u914d\u5217\u306f\u3001\u7d30\u80de\u63a5\u7740\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u542b\u307e\u308c\u308b\u3001\u7d30\u80de\u8868\u9762\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u7d50\u5408\u3059\u308b\u914d\u5217\u3067\u3059\u3002<\/p>\n<h3>\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3<\/h3>\n<p>\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3 (NeutrAvidin) \u306f\u3001\u30a2\u30d3\u30b8\u30f3\u304b\u3089\u7cd6\u9396\u3092\u9664\u53bb\u3057\u305f\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3059\u3002\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3\u306fRYD\u914d\u5217\u3092\u6301\u305f\u306a\u3044\u305f\u3081\u3001<strong>\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3\u306e\u3088\u3046\u306bRYD\u914d\u5217\u304c\u539f\u56e0\u3067\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u4e0a\u6607\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/strong>\u307e\u305f\u3001\u7cd6\u9396\u9664\u53bb\u3057\u3066\u3044\u308b\u305f\u3081\u30ec\u30af\u30c1\u30f3\u3068\u306e\u975e\u7279\u7570\u7684\u7d50\u5408\u304c\u6291\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3\u306e\u7b49\u96fb\u70b9\u306f\u4e2d\u6027\u4ed8\u8fd1\u306b\u3042\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u7cd6\u9396\u9664\u53bb\u306b\u3088\u3063\u3066\u30d3\u30aa\u30c1\u30f3\u3068\u306e\u7d50\u5408\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u306f\u4f4e\u4e0b\u3057\u307e\u305b\u3093\u3002<\/p>\n<h2>\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u8907\u5408\u4f53<\/h2>\n<p><strong>\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u9593\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u306f\u975e\u5e38\u306b\u9ad8\u304f\uff08Ka = 10<sup>-15<\/sup>M\uff09\u3001\u4e00\u5ea6\u8907\u5408\u4f53\u3092\u5f62\u6210\u3059\u308b\u3068\u3001pH\u3001\u6e29\u5ea6\u3001\u6709\u6a5f\u6eb6\u5a92\u3084\u5909\u6027\u5264\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/strong>\u3053\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u306e\u9ad8\u3055\u306f\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u8907\u5408\u4f53\u3067\u3082\u30cb\u30e5\u30fc\u30c8\u30e9\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u8907\u5408\u4f53\u3067\u3082\u540c\u3058\u3067\u3059\u3002\u30a2\u30d3\u30b8\u30f3-\u30d3\u30aa\u30c1\u30f3\u8907\u5408\u4f53\u3092\u78ba\u5b9f\u306b\u89e3\u96e2\u3055\u305b\u308b\u5834\u5408\u306f\u30018M\u30b0\u30a2\u30cb\u30b8\u30f3\u5869\u9178\uff08pH 1.5\uff09\u3067\u306e\u51e6\u7406\u3084SDS\u30b5\u30f3\u30d7\u30eb\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u3067\u306e\u716e\u6cb8\u3092\u884c\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3053\u306e\u6761\u4ef6\u3067\u306f\u3001\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u975e\u5909\u6027\u72b6\u614b\u3067\u56de\u53ce\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u3067\u3059\u3002\u6a19\u7684\u5206\u5b50\u306e\u5909\u6027\u3092\u907f\u3051\u3066\u56de\u53ce\u3059\u308b\u65b9\u6cd5\u3068\u3057\u3066\u306f\u3001\u30b9\u30da\u30fc\u30b5\u30fc\u30a2\u30fc\u30e0\u90e8\u5206\u306b\u30b8\u30b9\u30eb\u30d5\u30a3\u30c9\u7d50\u5408\u3092\u6709\u3059\u308b\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u8a66\u85ac\uff08\u56f32\uff09\u3092\u5229\u7528\u3057\u3001\u30a2\u30d3\u30b8\u30f3\u3068\u306e\u5207\u308a\u96e2\u3057\u306b\u9084\u5143\u5264\u3092\u5229\u7528\u3059\u308b\u65b9\u6cd5\u3084\u3001\u30e2\u30ce\u30de\u30fc\u5316\u3057\u305f\u30a2\u30d3\u30b8\u30f3\u3092\u5229\u7528\u3059\u308b\u65b9\u6cd5\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/20228?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa20_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce Immobilized Monomeric Avidin Agarose<\/a>\u306f\u3001\u30a2\u30d3\u30b8\u30f3\u306e\u30b5\u30d6\u30e6\u30cb\u30c3\u30c8\u30e2\u30ce\u30de\u30fc\u3092\u30a2\u30ac\u30ed\u30fc\u30b9\u62c5\u4f53\u306b\u56fa\u5b9a\u5316\u3057\u305f\u88fd\u54c1\u3067\u3001\u30d3\u30aa\u30c1\u30f3\u306b\u5bfe\u3059\u308b\u7279\u7570\u6027\u306f\u4fdd\u6301\u3057\u306a\u304c\u3089\u3001\u30d3\u30aa\u30c1\u30f3\u3068\u306e\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u30fc\u304c\u4f4e\u3044\uff08Ka = 10<sup>-8<\/sup>M\uff09\u305f\u3081\u3001\u30d3\u30aa\u30c1\u30f3\uff082 mM\uff09\u3092\u542b\u3080\u30ea\u30f3\u9178\u7de9\u885d\u751f\u7406\u98df\u5869\u6c34\uff08PBS\uff09\u3092\u7528\u3044\u305f\u7a4f\u3084\u304b\u306a\u6761\u4ef6\u4e0b\u3067\u3001\u7af6\u5408\u7684\u306b\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u56de\u53ce\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_371\" style=\"width: 389px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic10-fig2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-371\" class=\"size-full wp-image-371\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic10-fig2.jpg\" alt=\"protein-basic10-fig2\" width=\"379\" height=\"196\" \/><\/a><p id=\"caption-attachment-371\" class=\"wp-caption-text\">\u56f32 \u9084\u5143\u5207\u65ad\u53ef\u80fd\u306a\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u8a66\u85ac\u306e\u4f8b<\/p><\/div>\n<h2>\u6700\u5f8c\u306b<\/h2>\n<p>\u30d3\u30aa\u30c1\u30f3\u3068\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5e02\u8ca9\u54c1\u3092\u542b\u3081\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u4f53\u304c\u5165\u624b\u3067\u304d\u306a\u3044\u5834\u5408\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u5bfe\u3059\u308b\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u6280\u8853\u3082\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u6b21\u56de\u306f\u5404\u7a2e\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u8a66\u85ac\u306e\u7279\u9577\u3084\u6ce8\u610f\u70b9\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa20_Social_LAB\n\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<h2>\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u95a2\u9023\u3001\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089<\/h2>\n<table style=\"border-color: lightgray;border-collapse: collapse;padding: 20px\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"border-color: lightgray;padding: 20px\">\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic11\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa20_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c11\u56de\u3011\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u8a66\u85ac\u307e\u3068\u3081<br \/>\n<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u56de\u306f\u3001\u514d\u75ab\u691c\u51fa\u3001\u7279\u5b9a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3001\u7d30\u80de\u5206\u96e2\u3068\u3044\u3063\u305f\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u5e83\u304f\u5229\u7528\u3055\u308c\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01<\/p>\n","protected":false},"author":988,"featured_media":2161,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[237,21],"division":[],"class_list":["post-117","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-protein-experiments","tag-protein-analysis","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de\" \/>\n<meta property=\"og:description\" content=\"\u4eca\u56de\u306f\u3001\u514d\u75ab\u691c\u51fa\u3001\u7279\u5b9a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3001\u7d30\u80de\u5206\u96e2\u3068\u3044\u3063\u305f\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u5e83\u304f\u5229\u7528\u3055\u308c\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-03T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-24T10:23:49+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/faae1908c312f30554c8d79b37735323\"},\"headline\":\"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-07-24T10:23:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/\"},\"wordCount\":76,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/protein-basic-title-8.jpg\",\"keywords\":[\"\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\",\"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/\",\"name\":\"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/protein-basic-title-8.jpg\",\"datePublished\":\"2020-03-03T15:00:00+00:00\",\"dateModified\":\"2025-07-24T10:23:49+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/faae1908c312f30554c8d79b37735323\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/protein-basic-title-8.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/protein-basic-title-8.jpg\",\"width\":1200,\"height\":630,\"caption\":\"protein-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic10\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/faae1908c312f30554c8d79b37735323\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/","og_locale":"ja_JP","og_type":"article","og_title":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de","og_description":"\u4eca\u56de\u306f\u3001\u514d\u75ab\u691c\u51fa\u3001\u7279\u5b9a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3001\u7d30\u80de\u5206\u96e2\u3068\u3044\u3063\u305f\u751f\u5316\u5b66\u5b9f\u9a13\u306b\u5e83\u304f\u5229\u7528\u3055\u308c\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff01","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-03-03T15:00:00+00:00","article_modified_time":"2025-07-24T10:23:49+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/faae1908c312f30554c8d79b37735323"},"headline":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-07-24T10:23:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/"},"wordCount":76,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","keywords":["\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13","\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/","name":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","datePublished":"2020-03-03T15:00:00+00:00","dateModified":"2025-07-24T10:23:49+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/faae1908c312f30554c8d79b37735323"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","width":1200,"height":630,"caption":"protein-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"10\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c10\u56de"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/faae1908c312f30554c8d79b37735323","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":237,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13"},{"value":21,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":237,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13","slug":"protein-experiments","term_group":0,"term_taxonomy_id":237,"taxonomy":"post_tag","description":"\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c\u30b7\u30ea\u30fc\u30ba","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":21,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790","slug":"protein-analysis","term_group":0,"term_taxonomy_id":21,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":117,"position":0},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":117,"position":1},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25170,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody-purification-vaccine-bpg-26018\/","url_meta":{"origin":117,"position":2},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\u7cbe\u88fd\u306e\u57fa\u790e\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u6a39\u8102\u9078\u629e","author":"LatB Staff","date":"2026\u5e745\u670819\u65e5","format":false,"excerpt":"\u5c0e\u5165 \u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\uff08bispecific antibody\u3001\u4ee5\u4e0bBsAb\uff09\u306f\u30012\u3064\u306e\u7570\u306a\u308b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":117,"position":3},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25623,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-flow-cytometry-ts-r-25069\/","url_meta":{"origin":117,"position":4},"title":"\u3010\u7b2c9\u56de\u3011 \u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u7528\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u56de\u53ce","author":"LatB Staff","date":"2026\u5e7410\u670830\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30ca\u30ce\u30b5\u30a4\u30ba\u306e\u5c0f\u80de\uff08\u76f4\u5f8430\uff5e100 nm\uff09\u3067\u3042\u308b\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u3092\u3001\u78c1\u6c17\u30d3\u30fc\u30ba\uff08Invitro\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":117,"position":5},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/protein-basic-title-8.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=117"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/117\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2161"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=117"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=117"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=117"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}