{"id":11765,"date":"2022-05-31T09:10:02","date_gmt":"2022-05-31T00:10:02","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=11765"},"modified":"2022-06-16T17:04:01","modified_gmt":"2022-06-16T08:04:01","slug":"microarray-software-voc1-ts","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/","title":{"rendered":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066"},"content":{"rendered":"<p>\u672c\u30a8\u30f3\u30c8\u30ea\u30fc\u3067\u306f\u5f0a\u793e\u306eApplied Biosystems\u2122 TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u3054\u5229\u7528\u3044\u305f\u3060\u3044\u305f\u300c\u304a\u5ba2\u3055\u307e\u306e\u58f0\u300d\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb \u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u304a\u624b\u8efd\u306b\u5b9f\u65bd\u3055\u308c\u305f\u3044\u65b9<br \/>\n\u30fb \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u3092\u6271\u3044\u305f\u3044\u3001\u89e3\u6790\u3055\u308c\u305f\u3044\u65b9<br \/>\n\u30fb \u7db2\u7f85\u7684\u767a\u73fe\u89e3\u6790\u306e\u30b0\u30e9\u30d5\u3092\u4f5c\u6210\u3055\u308c\u305f\u3044\u65b9<br \/>\n\u30fb \u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u304b\u3089\u907a\u4f1d\u5b50\u306e\u7d5e\u308a\u8fbc\u307f\u3092\u3055\u308c\u305f\u3044\u65b9<\/p>\n<p>\u25bcKey Word<br \/>\n\u7121\u511f<br \/>\n\u7c21\u5358<br \/>\n\u308f\u304b\u308a\u3084\u3059\u3044<br \/>\n\u76f4\u89b3\u7684\u306b\u4f7f\u3048\u308b<br \/>\n\u65e9\u3044<br \/>\n\u5145\u5b9f<br \/>\nBioinformatics<\/p>\n<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u5f0a\u793e\u306eWeb\u30b5\u30a4\u30c8\u304b\u3089\u7121\u6599\u3067\u5165\u624b\u3067\u304d\u308b\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2Transcriptome Analysis Console (TAC)\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f2013\u5e74\u306bver.1\u304c\u30ea\u30ea\u30fc\u30b9\u3055\u308c\u305f\u5f8c\u3001\u591a\u304f\u306e\u7686\u3055\u307e\u306b\u3054\u5229\u7528\u3044\u305f\u3060\u304d\u3001\u30d0\u30fc\u30b8\u30e7\u30f3\u30a2\u30c3\u30d7\u3092\u91cd\u306d\u306a\u304c\u3089\u3001\u304a\u304b\u3052\u3055\u307e\u3067\u6700\u65b0\u7248\u306fver.4.0.2\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5f0a\u793e\u958b\u50ac\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u30bb\u30df\u30ca\u30fc\u3084\u3001\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306b\u3054\u53c2\u52a0\u3044\u305f\u3060\u3044\u305f\u65b9\u3001\u30e1\u30fc\u30eb\u3084\u96fb\u8a71\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u3044\u305f\u65b9\u304b\u3089\u3001\u3054\u597d\u8a55\u3092\u3044\u305f\u3060\u3044\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u305d\u306e\u3046\u3061\u306e\u5e7e\u3064\u304b\u3092\u3054\u7d39\u4ecb\u3055\u305b\u3066\u3044\u305f\u3060\u304d\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h2>\u601d\u3063\u3066\u3044\u305f\u3088\u308a\u7c21\u5358\u3067\u3057\u305f<\/h2>\n<p>\u300e\u8b1b\u7fd2\u3092\u53d7\u3051\u308b\u524d\u306b\u8a66\u3057\u306b\u81ea\u5206\u3067\u4f7f\u3063\u3066\u307f\u305f\u3089\u9a5a\u304f\u307b\u3069\u7c21\u5358\u306b\u89e3\u6790\u304c\u51fa\u6765\u3066\u3057\u307e\u3063\u305f\u3002\u300f<br \/>\n\uff08\u8b1b\u7fd2\u3068\u306f\u5f0a\u793e\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30bb\u30df\u30ca\u30fc\u3092\u6307\u3057\u307e\u3059\u3002\uff09<\/p>\n<p>\u300e\u81ea\u5206\u3067\u89e3\u6790\u304c\u51fa\u6765\u308b\u304b\u4e0d\u5b89\u3060\u3063\u305f\u304c\u3001\u975e\u5e38\u306b\u4f7f\u3044\u3084\u3059\u305d\u3046\u3067\u81ea\u4fe1\u304c\u6301\u3066\u305f\u3002\u300f<\/p>\n<p>\u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3068\u306a\u308a\u307e\u3059\u3068\u3001\u6570\u4e07\uff5e\u5341\u6570\u4e07\u306e\u907a\u4f1d\u5b50\u30c7\u30fc\u30bf\u3092\u4e00\u6c17\u306b\u6271\u3046\u305f\u3081\u300c\u96e3\u3057\u305d\u3046\u300d\u3068\u3044\u3046\u30a4\u30e1\u30fc\u30b8\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n<p>\u3067\u3059\u304c\u3001TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u305d\u306e\u3088\u3046\u306a\u5fc3\u914d\u306f\u3054\u7121\u7528\u3067\u3059\u3002\u300c\u96e3\u3057\u305d\u3046\u300d\u3068\u3044\u3046\u5148\u5165\u89b3\u304c\u6700\u5927\u306e\u96e3\u95a2\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11-1024x290.jpg\" alt=\"\" width=\"760\" height=\"215\" class=\"aligncenter size-large wp-image-11779\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11-1024x290.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11-300x85.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11-768x217.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11-1536x435.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc11.jpg 1865w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p class=\"bottom_space\">\n<div style=\"text-align: center\">\u56f3\uff11\uff0eTAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u30fc\u30e0\u767a\u73fe\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u305f\u3081\u3001\u52b9\u7387\u5316\u3055\u308c\u305f\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/div>\n<\/p>\n<p><h2>\u30b0\u30e9\u30d5\u4f5c\u6210\u304c\u4f7f\u3048\u308b\uff01<\/h2>\n<\/p>\n<p>\u300e\u30b0\u30e9\u30d5\u304c\u975e\u5e38\u306b\u308f\u304b\u308a\u3084\u3059\u3044\u3002\u3053\u306e\u30b0\u30e9\u30d5\u3092\u4f7f\u3046\u305f\u3081\u306b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u5229\u7528\u3057\u305f\u3044\u3068\u601d\u3063\u305f\u3002\u300f(NGS\u306eRNA-seq  \u3068\u6bd4\u8f03\u3057\u3066\u306e\u30b3\u30e1\u30f3\u30c8\u3067\u3059\u3002)<\/p>\n<p>\u300eVolcano Plot\uff08\u30dc\u30eb\u30b1\u30fc\u30ce\u30fc\u30d7\u30ed\u30c3\u30c8\uff09\u304c\u6570\u79d2\u3067\u3067\u304d\u308b\u306e\u306b\u9a5a\u3044\u305f\u3001\u304b\u306a\u308a\u4f7f\u3048\u305d\u3046\u300f<\/p>\n<p>\u300e\uff08TAC\u3067\u4f5c\u6210\u3055\u308c\u308b\u30b0\u30e9\u30d5\u306f\uff09\u8ad6\u6587\u3067\u3082\u898b\u305f\u3053\u3068\u304c\u3042\u308b\u56f3\u3070\u304b\u308a\u3067\u5b9f\u7528\u7684\u3060\u3002\u300f<\/p>\n<p>\u89e3\u6790\u3092\u7121\u4e8b\u306b\u7d42\u3048\u3089\u308c\u3066\u3082\u3001\u8ad6\u6587\u767a\u8868\u3084\u53e3\u6f14\u306e\u305f\u3081\u306b\u306f\u3001\u5206\u304b\u308a\u3084\u3059\u3044\u3088\u3046\u306b\u89e3\u6790\u7d50\u679c\u306e\u56f3\u793a\u5316\u3082\u5fc5\u8981\u3067\u3059\u3002TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306f\u7c21\u5358\u306b\u30b0\u30e9\u30d5\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3057\u3001\u30a8\u30af\u30b9\u30dd\u30fc\u30c8\u3057\u305f\u56f3\u306f\u3001\u8ad6\u6587\u306b\u3082\u305d\u306e\u307e\u307e\u63b2\u8f09\u3055\u308c\u3066\u3044\u308b\u4f8b\u304c\u591a\u304f\u3042\u308a\u307e\u3059\u3002\u3053\u3046\u3044\u3063\u305f\u6a5f\u80fd\u307e\u3067\u5099\u3048\u3066\u3044\u308b\u306e\u3067\u3001\u30b0\u30e9\u30d5\u4f5c\u6210\u306e\u305f\u3081\u306b\u5225\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u5fc5\u8981\u3068\u305b\u305a\u3001\u4fbf\u5229\u3067\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc-10-1024x380.jpg\" alt=\"microarray-voc-10\" width=\"760\" height=\"282\" class=\"aligncenter size-large wp-image-11775\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc-10-1024x380.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc-10-300x111.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc-10-768x285.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/microarray-voc-10.jpg 1322w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p class=\"bottom_space\">\n<div style=\"text-align: center\">\u56f3\uff12\uff0e\u30b9\u30ad\u30e3\u30c3\u30bf\u30fc\u30d7\u30ed\u30c3\u30c8\u3001\u30dc\u30eb\u30b1\u30fc\u30ce\u30fc\u30d7\u30ed\u30c3\u30c8\u3001\u968e\u5c64\u5316\u30af\u30e9\u30b9\u30bf\u30ea\u30f3\u30b0\uff08\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\uff09<\/div>\n<\/p>\n<p><h2>\u8868(Gene Table)\u304c\u898b\u3084\u3059\u3044\u3001\u6a5f\u80fd\u7684<\/h2>\n<\/p>\n<p>\u300e\u5de6\u5074\u306e\u8868\u306e\u3068\u3053\u308d\u306e\u30d5\u30a3\u30eb\u30bf\u30fc\u6a5f\u80fd\u304cExcel\u307f\u305f\u3044\u3067\u3088\u3044\u3002\u300f<\/p>\n<p>\u300e\u53d7\u8a17\u4f1a\u793e\u304b\u3089\u89e3\u6790\u7d50\u679c\u3092Excel\u3067\u8cb0\u3063\u3066\u3044\u305f\u304c\u3001\u3053\u308c\u3092\u898b\u308b\u3088\u308a\u3082\u3001\u81ea\u5206\u3067CEL\u30d5\u30a1\u30a4\u30eb\uff08\u751f\u30c7\u30fc\u30bf\uff09\u304b\u3089\u89e3\u6790\u3057\u305f\u65b9\u304c\u308f\u304b\u308a\u3084\u3059\u304b\u3063\u305f\u3002\u300f<\/p>\n<p>TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u767a\u73fe\u89e3\u6790\u7d50\u679c\u306e\u30a6\u30a3\u30f3\u30c9\u30a6\u306f\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u3067\u5de6\u5074\u306bGene Table\u3001\u53f3\u5074\u306b\u30b0\u30e9\u30d5\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u306eGene Table\u3067\u3001\u5404\u907a\u4f1d\u5b50\u306e\u540d\u524d\u3084\u767a\u73fe\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306a\u3069\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u304c\u3001Excel\u2122 \u306e\u30d5\u30a3\u30eb\u30bf\u30fc\u6a5f\u80fd\u306e\u3088\u3046\u306a\u6a5f\u80fd\u304c\u5099\u308f\u3063\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u308c\u3092\u7528\u3044\u3066\u3001\u6761\u4ef6\u306b\u5408\u3046\u6570\u5024\u3084\u6587\u5b57\u5217\u3067\u7d5e\u308a\u3053\u3080\u3001\u6607\u9806\u30fb\u964d\u9806\u306b\u4e26\u3073\u66ff\u3048\u308b\u306a\u3069\u304c\u884c\u3048\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001Gene Table \u3068\u30b0\u30e9\u30d5\u306f\u9023\u52d5\u3057\u3066\u304a\u308a\u3001\u76f4\u611f\u7684\u306b\u7406\u89e3\u3057\u3084\u3059\u3044\u30c7\u30b6\u30a4\u30f3\u3067\u3059\u3002Gene Table\u3067\u9078\u629e\u3057\u305f\u907a\u4f1d\u5b50\u306f\u3001\u30b0\u30e9\u30d5\u3067\u3082\u30cf\u30a4\u30e9\u30a4\u30c8\u3055\u308c\u3001\u9006\u306b\u30b0\u30e9\u30d5\u306e\u65b9\u3067\u30d7\u30ed\u30c3\u30c8\u3092\u9078\u629e\u3059\u308b\u3068\u3001Gene Table \u3067\u8a72\u5f53\u3059\u308b\u907a\u4f1d\u5b50\u304c\u30cf\u30a4\u30e9\u30a4\u30c8\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>Gene Table \u3068\u30b0\u30e9\u30d5\u3068\u3092\u76f8\u4e92\u306b\u898b\u6bd4\u3079\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u89e3\u6790\u7d50\u679c\u3092\u7406\u89e3\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-1024x643.png\" alt=\"microarray-voc5\" width=\"760\" height=\"477\" class=\"aligncenter size-large wp-image-11770\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-1024x643.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-300x188.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-768x482.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-1536x965.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-2048x1286.png 2048w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/figure-3-320x200.png 320w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p class=\"bottom_space\">\n<div style=\"text-align: center\">\u56f33\uff0eTAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306eGene Table\u3002Excel\u306e\u3088\u3046\u306b\u30d5\u30a3\u30eb\u30bf\u30fc\u6a5f\u80fd\u304c\u5099\u308f\u3063\u3066\u3044\u308b\u306e\u3067\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u30c7\u30fc\u30bf\u306e\u6574\u7406\u3084\u7d5e\u308a\u8fbc\u307f\u3092\u7c21\u5358\u306b\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/div>\n<\/p>\n<p><h2>\u307e\u3068\u3081<\/h2>\n<\/p>\n<p>\u4ee5\u4e0a\u3001\u5b9f\u969b\u306bTAC\u3092\u3054\u4f7f\u7528\u3044\u305f\u3060\u3044\u305f\u3001\u30e6\u30fc\u30b6\u30fc\u69d8\u306e\u3054\u611f\u60f3\u3092\u7d39\u4ecb\u3055\u305b\u3066\u3044\u305f\u3060\u304d\u307e\u3057\u305f\u3002<\/p>\n<p>\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30c7\u30fc\u30bf\u89e3\u6790\u304c\u5927\u5909\u305d\u3046\u3060\u3001\u3068\u304a\u60a9\u307f\u306e\u65b9\u306f\u3001TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u3054\u5229\u7528\u3092\u662f\u975e\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002\u7279\u306b\u6761\u4ef6\u306a\u304f\u3001\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3001\u30a4\u30f3\u30b9\u30c8\u30fc\u30eb\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u307e\u305a\u306f\u30c7\u30e2\u30c7\u30fc\u30bf\u3084GEO\u306b\u767b\u9332\u3055\u308c\u3066\u3044\u308b\u30c7\u30fc\u30bf\u3067\u3001\u4f7f\u3044\u52dd\u624b\u3092\u304a\u8a66\u3057\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306e\u65b9\u6cd5\u304b\u3089\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u3064\u3044\u3066\u3001\u7121\u511f\u306e\u30bb\u30df\u30ca\u30fc\u3092\u958b\u50ac\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u3061\u3089\u306e\u3054\u53c2\u52a0\u3082\u3069\u3046\u305e\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Excel is a trademark of Microsoft Corporation .<\/p>\n<p>\u95a2\u9023\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/microarray-tac.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u30c7\u30fc\u30bf\u3092\u89e3\u6790\u3057\u3066\u307f\u307e\u3057\u3087\u3046<br \/>\uff5e\u7121\u511f\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2TAC\u306e\u3054\u7d39\u4ecb\uff5e<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/microarray-gene-expression.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u57fa\u790e\u304b\u3089\u308f\u304b\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u30bb\u30df\u30ca\u30fc<br \/>\uff5e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u539f\u7406\u304b\u3089\u4f7f\u7528\u4f8b\u306e\u3054\u7d39\u4ecb\uff5e<\/a><\/p>\n<p>\u95a2\u9023\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/microarray.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u4eca\u65e5\u304b\u3089\u59cb\u3081\u308b\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4 \uff1a \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<br \/>\uff5e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u539f\u7406\u304b\u3089\u30c7\u30fc\u30bf\u89e3\u6790\u307e\u3067\uff5e<\/a><\/p>\n<p>\u95a2\u9023\u8a18\u4e8b\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/start-microarray?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u306f\uff1f\uff5c\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u767a\u73fe\u89e3\u6790\u306e\u539f\u7406\u3068\u89e3\u6790\u65b9\u6cd5<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_4\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30d5\u30ea\u30fc\u306e\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u30bd\u30d5\u30c8\u3092\u4f7f\u3063\u3066\u767a\u73fe\u89e3\u6790\u3057\u3066\u307f\u3088\u3046\uff01<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tac_ma_gsd_ts_1\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u306b\uff01\u7c21\u5358\u3067\u9ad8\u6a5f\u80fd\u3001\u7121\u6599\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u30b9\u30b9\u30e1<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/software_ma_gsd_ts_1\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_ma3_microarray-software-voc1-ts_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u3093\u306a\u306b\u7c21\u5358\uff01\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u30d5\u30ea\u30fc\u30bd\u30d5\u30c8\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b\u65b9\u6cd5<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u672c\u30a8\u30f3\u30c8\u30ea\u30fc\u3067\u306f\u5f0a\u793e\u306eApplied Biosystems\u2122 TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u3054\u5229\u7528\u3044\u305f\u3060\u3044\u305f\u300c\u304a\u5ba2\u3055\u307e\u306e\u58f0\u300d\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb \u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u304a\u624b\u8efd\u306b\u5b9f\u65bd\u3055\u308c\u305f\u3044\u65b9 \u30fb <\/p>\n","protected":false},"author":975,"featured_media":12031,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":["post-11765","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066\" \/>\n<meta property=\"og:description\" content=\"\u672c\u30a8\u30f3\u30c8\u30ea\u30fc\u3067\u306f\u5f0a\u793e\u306eApplied Biosystems\u2122 TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u3054\u5229\u7528\u3044\u305f\u3060\u3044\u305f\u300c\u304a\u5ba2\u3055\u307e\u306e\u58f0\u300d\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb \u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u304a\u624b\u8efd\u306b\u5b9f\u65bd\u3055\u308c\u305f\u3044\u65b9 \u30fb\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-31T00:10:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-16T08:04:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"815\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066\",\"datePublished\":\"2022-05-31T00:10:02+00:00\",\"dateModified\":\"2022-06-16T08:04:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/\"},\"wordCount\":56,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic5.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/\",\"name\":\"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic5.jpg\",\"datePublished\":\"2022-05-31T00:10:02+00:00\",\"dateModified\":\"2022-06-16T08:04:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic5.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic5.jpg\",\"width\":815,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/microarray-software-voc1-ts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/","og_locale":"ja_JP","og_type":"article","og_title":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066","og_description":"\u672c\u30a8\u30f3\u30c8\u30ea\u30fc\u3067\u306f\u5f0a\u793e\u306eApplied Biosystems\u2122 TAC\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u3054\u5229\u7528\u3044\u305f\u3060\u3044\u305f\u300c\u304a\u5ba2\u3055\u307e\u306e\u58f0\u300d\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u30fb \u7db2\u7f85\u7684\u306a\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3092\u304a\u624b\u8efd\u306b\u5b9f\u65bd\u3055\u308c\u305f\u3044\u65b9 \u30fb","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-05-31T00:10:02+00:00","article_modified_time":"2022-06-16T08:04:01+00:00","og_image":[{"width":815,"height":1000,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066","datePublished":"2022-05-31T00:10:02+00:00","dateModified":"2022-06-16T08:04:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/"},"wordCount":56,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/","name":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","datePublished":"2022-05-31T00:10:02+00:00","dateModified":"2022-06-16T08:04:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","width":815,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/microarray-software-voc1-ts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u300e\u7c21\u5358\u3067\u3044\u3044\u3067\u3059\u306d\u300f\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3064\u3044\u3066"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg",760,933,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":11765,"position":0},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":11765,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":11765,"position":2},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":11765,"position":3},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":11765,"position":4},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":11765,"position":5},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic5.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=11765"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/11765\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12031"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=11765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=11765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=11765"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=11765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}