{"id":12053,"date":"2022-06-29T18:13:57","date_gmt":"2022-06-29T09:13:57","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12053"},"modified":"2022-07-13T11:03:08","modified_gmt":"2022-07-13T02:03:08","slug":"basic_ngs_history_gsd_ts","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/","title":{"rendered":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca"},"content":{"rendered":"<p>2010\u5e74\u306eIon PGM\u2122\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u767b\u5834\u304b\u308912\u5e74\u3002NGS\u3092\u53d6\u308a\u5dfb\u304f\u74b0\u5883\u306f\u3001\u8ab0\u306b\u3082\u4e88\u60f3\u3067\u304d\u306a\u304b\u3063\u305f\u307b\u3069\u306e\u901f\u3055\u3067\u9032\u5316\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eNGS\u30d6\u30e9\u30f3\u30c9\u3067\u3042\u308bIon Torrent\u2122 \u30d6\u30e9\u30f3\u30c9\u3082\u3001\u3053\u306e12\u5e74\u306e\u9593\u306b\u5927\u304d\u306a\u5909\u5316\u3092\u9042\u3052\u307e\u3057\u305f\u3002\u4eca\u56de\u306fIon Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u5909\u9077\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fbNGS\u306e\u6b74\u53f2\u306b\u8208\u5473\u306e\u3042\u308b\u65b9<br \/>\n\u30fbNGS\u89e3\u6790\u3092\u3053\u308c\u304b\u3089\u59cb\u3081\u305f\u3044\u65b9<\/p>\n<h2>\u6c34\u7d20\u30a4\u30aa\u30f3\u3092\u5229\u7528\u3059\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u958b\u767a<\/h2>\n<p>Ion Torrent\u306f\u30d1\u30a4\u30ed\u30b7\u30fc\u30b1\u30f3\u30b9\u6cd5\u3092\u521d\u3081\u3066NGS\u306b\u5fdc\u7528\u3057\u305fJonathan Rothberg\u6c0f\u306b\u3088\u3063\u3066\u8a2d\u7acb\u3055\u308c\u307e\u3057\u305f\u30022010\u5e74\u3001\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u3068\u6c34\u7d20\u30a4\u30aa\u30f3\u3092\u7528\u3044\u305f\u30b7\u30fc\u30b1\u30f3\u30b9\u6280\u8853\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u3053\u308c\u307e\u3067\u306b\u306a\u3044\u5168\u304f\u65b0\u3057\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u304c\u767a\u8868\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u304cIon PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3068\u547c\u3070\u308c\u308b\u30e2\u30c7\u30eb\u3067\u3001\u4eca\u307e\u3067\u306e\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u306f\u306a\u304b\u3063\u305f\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-technology.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_basic_ngs_history_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u305d\u306e\u3082\u306e\u304c\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u306a\u308b<\/a>\u300d\u3068\u3044\u3046\u3053\u3068\u304c\u6700\u5927\u306e\u7279\u9577\u3067\u3042\u308a\u3001\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u306b\u3088\u308a\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u4f7f\u3044\u5206\u3051\u308b\u3068\u3044\u3046\u73fe\u5728\u306eIon Torrent\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u5171\u901a\u306e\u30b3\u30f3\u30bb\u30d7\u30c8\u306f\u3059\u3067\u306b\u3067\u304d\u3042\u304c\u3063\u3066\u3044\u307e\u3057\u305f\u3002<br \/>\n\u5c0f\u3055\u306a\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u8868\u9762\u306b\u306f\u7121\u6570\u306e\u30a6\u30a7\u30eb\uff08\u30bb\u30f3\u30b5\u30fc\uff09\u304c\u3042\u308a\u3001\u5404\u30a6\u30a7\u30eb\u5185\u306b\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u304c\u7d50\u5408\u3057\u305f\u5c0f\u3055\u306a\u30d3\u30fc\u30ba\u304c\u57cb\u3081\u8fbc\u307e\u308c\u307e\u3059\u3002\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u5185\u306bdNTP\u3092\u9806\u756a\u306b\u9001\u6db2\u3057\u3001\u5869\u57fa\u306e\u4f38\u9577\u53cd\u5fdc\u6642\u306b\u653e\u51fa\u3055\u308c\u308b\u6c34\u7d20\u30a4\u30aa\u30f3\u306b\u3088\u308bpH\u5909\u5316\u3092\u691c\u51fa\u3057\u3066\u5869\u57fa\u914d\u5217\u3092\u6c7a\u5b9a\u3057\u3066\u3044\u304d\u307e\u3059<sup>1<\/sup>\u3002<br \/>\n\u3053\u306eIon PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u3001\u30d9\u30f3\u30c1\u30c8\u30c3\u30d7\u578b\u3001\u691c\u51fa\u539f\u7406\u304c\u30b7\u30f3\u30d7\u30eb\u3067\u9ad8\u901f\u3001\u4f4e\u4fa1\u683c\u3067\u3042\u3063\u305f\u3053\u3068\u304c\u5927\u5909\u306a\u8a55\u5224\u3068\u306a\u308a\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u4e16\u754c\u3092\u4e00\u822c\u30e6\u30fc\u30b6\u30fc\u306b\u62e1\u5927\u3059\u308b\u3053\u3068\u306b\u5927\u304d\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3057\u305f\u3002\u540c\u5e74\u3001\u30e9\u30a4\u30d5\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u30ba (\u65e7\u30a4\u30f3\u30d3\u30c8\u30ed\u30b8\u30a7\u30f3)\u3000\u304cIon Torrent\u3092\u8cb7\u53ce\u3057\u3001Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u88fd\u9020\u304a\u3088\u3073\u8ca9\u58f2\u3092\u624b\u639b\u3051\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-12087\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg\" alt=\"IonTorrentHistory\" width=\"1000\" height=\"667\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg 1000w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577-96x65.jpg 96w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<h2>\u30c9\u30a4\u30c4\u306b\u304a\u3051\u308b\u75c5\u539f\u6027\u5927\u8178\u83cc\u306e\u30a2\u30a6\u30c8\u30d6\u30ec\u30a4\u30af<\/h2>\n<p>Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u304c\u767b\u5834\u3057\u305f\u305d\u306e\u5e74\u3001\u30c9\u30a4\u30c4\u3067\u75c5\u539f\u6027\u5927\u8178\u83ccO104-H4\u306e\u5927\u898f\u6a21\u306a\u30a2\u30a6\u30c8\u30d6\u30ec\u30a4\u30af\u304c\u767a\u751f\u3057\u307e\u3057\u305f\u3002\u5f53\u521d\u3001\u539f\u56e0\u306f\u65b0\u7a2e\u306e\u75c5\u539f\u83cc\u3068\u7591\u308f\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u767a\u751f\u304b\u3089\u308f\u305a\u304b2\u9031\u9593\u3067\u30c9\u30e9\u30d5\u30c8\u306a\u304c\u3089\u3082\u75c5\u539f\u83cc\u306e\u5168\u30b2\u30ce\u30e0\u3092\u6c7a\u5b9a\u3057\u3001\u5bfe\u8c61\u306e\u682a\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306ePCR\u691c\u51fa\u6cd5\u304c\u78ba\u7acb\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u306e\u6642\u306e\u5869\u57fa\u914d\u5217\u89e3\u8aad\u306b\u4f7f\u7528\u3055\u308c\u305f\u30b7\u30fc\u30b1\u30f3\u30b5\u3053\u305d\u304cIon PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3060\u3063\u305f\u306e\u3067\u3059\u3002\u30c7\u30b9\u30af\u30c8\u30c3\u30d7\u578b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u5229\u70b9\u304b\u3089Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u591a\u304f\u306e\u7814\u7a76\u8005\u306b\u63a1\u7528\u3055\u308c\u3001\u4e00\u8e8d\u305d\u306e\u77e5\u540d\u5ea6\u3092\u4e0a\u3052\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3057\u305f<sup>2<\/sup>\u3002<\/p>\n<h2>\u3055\u307e\u3056\u307e\u306a\u6539\u826f\u3068\u8ab2\u984c<\/h2>\n<p>Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u767a\u58f2\u5f53\u521d\u3001\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u3078\u306e\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u5145\u586b\u7387\u3092\u4e0a\u3052\u308b\u3053\u3068\u304c\u8ab2\u984c\u3067\u3001\u5145\u586b\u7387\u3092\u793a\u3059\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u306f50\uff05\u306b\u6e80\u305f\u306a\u3044\u9752\u3092\u793a\u3059\u3053\u3068\u304c\u5927\u534a\u3067\u3057\u305f\u3002Ion Torrent\u958b\u767a\u90e8\u9580\u3084\u4e00\u822c\u306e\u30e6\u30fc\u30b6\u30fc\u306f\u9ad8\u3044\u5145\u586b\u7387\u3092\u793a\u3059\u8d64\u3044\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u3001\u305d\u3057\u3066\u30ed\u30f3\u30b0\u30ea\u30fc\u30c9\u3092\u6c42\u3081\u3055\u307e\u3056\u307e\u306a\u53ef\u80fd\u6027\u3092\u6a21\u7d22\u3057\u307e\u3057\u305f\u3002\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u6642\u306e\u9060\u5fc3\u6642\u9593\u3084\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u8868\u9762\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u5909\u66f4\u3001\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u304b\u3089\u56de\u53ce\u307e\u3067\u81ea\u52d5\u5316\u3059\u308b\u30b7\u30b9\u30c6\u30e0\uff08Ion OneTouch\u2122 \u30b7\u30b9\u30c6\u30e0\uff09\u306a\u3069\u306e\u3042\u3089\u3086\u308b\u65b9\u6cd5\u304c\u76ee\u307e\u3050\u308b\u3057\u304f\u691c\u8a0e\u3055\u308c\u307e\u3057\u305f\u3002\u8a66\u85ac\u3084\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u6539\u826f\u30fb\u9032\u5316\u306e\u30b9\u30d4\u30fc\u30c9\u304c\u901f\u304f\u3001\u73fe\u5728\u306b\u3064\u306a\u304c\u308b\u57fa\u790e\u304c\u3067\u304d\u3042\u304c\u3063\u305f\u6642\u671f\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u6700\u7d42\u7684\u306b\u306f80\uff05\u3092\u8d85\u3048\u308b\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u7387\u3092\u5b89\u5b9a\u3057\u3066\u9054\u6210\u3059\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>2013\u5e74\u3001Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3088\u308a\u3082\u9ad8\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u767a\u63ee\u3059\u308b\u300cIon Proton\u2122 \u30b7\u30fc\u30b1\u30f3\u30b5\u300d\u304c\u767a\u58f2\u3055\u308c\u307e\u3057\u305f\u3002\u3088\u308a\u591a\u304f\u306e\u30c7\u30fc\u30bf\u91cf\u304c\u5f97\u3089\u308c\u308b\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u3092\u7528\u3044\u3066\u304a\u308a\u3001Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u96e3\u3057\u304b\u3063\u305f\u9ad8\u7b49\u751f\u7269\u306e\u30b2\u30ce\u30e0\u3084\u591a\u304f\u306e\u9818\u57df\u306e\u89e3\u6790\u3092\u53ef\u80fd\u306b\u3059\u308b\u30b9\u30da\u30c3\u30af\u3092\u6301\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306e\u8a66\u85ac\u985e\u306e\u6539\u826f\u306b\u3088\u308a\u3001Ion PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u306f400bp\u306e\u30ea\u30fc\u30c9\u9577\u3092\u9054\u6210\u3057\u307e\u3059\u3002\u30e1\u30bf\u30b2\u30ce\u30e0\u89e3\u6790\u3084\u5c11\u6570\u907a\u4f1d\u5b50\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u30b7\u30fc\u30b1\u30f3\u30b9\u306fIon PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u884c\u3044\u3001\u3088\u308a\u591a\u304f\u306e\u30c7\u30fc\u30bf\u91cf\u3092\u5fc5\u8981\u3068\u3059\u308b\u5834\u5408\u306fIon Proton\u30b7\u30fc\u30b1\u30f3\u30b5\u3092\u7528\u3044\u3066\u3068\u3044\u3046\u3088\u3046\u306b\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-applications.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_basic_ngs_history_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u591a\u69d8\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/a>\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u3055\u3089\u306b\u540c\u5e74\u3001\u5f85\u671b\u306eIon Chef\u2122 \u30b7\u30b9\u30c6\u30e0\u304c\u767a\u58f2\u306b\u306a\u308a\u307e\u3057\u305f\u3002Chef (\u30b7\u30a7\u30d5\uff1a\u6599\u7406\u9577)\u306e\u540d\u306e\u901a\u308a\u3001Ion OneTouch\u30b7\u30b9\u30c6\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3082\u306a\u304a\u7169\u96d1\u306a\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u304b\u3089\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u3078\u306e\u5145\u586b\u4f5c\u696d\u3092\u3059\u3079\u3066\u81ea\u52d5\u3067\u884c\u3046\u30b7\u30b9\u30c6\u30e0\u3067\u3059\u3002\u3061\u306a\u307f\u306b\u3053\u306eChef\u3068\u3044\u3046\u30cd\u30fc\u30df\u30f3\u30b0\u306f\u3001\u5f53\u521d\u3001\u305f\u3060\u306e\u958b\u767a\u30b3\u30fc\u30c9\u30cd\u30fc\u30e0\u3060\u3063\u305f\u305d\u3046\u3067\u3059\u3002<\/p>\n<p>Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u767b\u5834\u3057\u305f\u3082\u306e\u306e\u3001Ion Torrent\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u306f\u4f9d\u7136\u3068\u3057\u3066\u5f31\u70b9\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u305d\u308c\u306f\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u4f7f\u7528\u306b\u30b3\u30c4\u304c\u5fc5\u8981\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u9001\u6db2\u306b\u5fc5\u8981\u306a\u7a92\u7d20\u30ac\u30b9\u30dc\u30f3\u30d9\u306e\u6e96\u5099\u3001\u9001\u6db2\u8a66\u85ac\u3084dNTP\u306e\u8abf\u88fd\u2026\u3002\u8d85\u7d14\u6c34\u88c5\u7f6e\u3092\u4f7f\u7528\u3057\u3066\u3082\u65bd\u8a2d\u306b\u3088\u3063\u3066pH\u5b89\u5b9a\u6027\u304c\u7570\u306a\u308b\u3068\u3044\u3046\u3053\u3068\u304c\u751f\u3058\u3001\u4f55\u56de\u30c8\u30e9\u30a4\u3057\u3066\u3082pH\u304c\u57fa\u6e96\u5024\u306b\u5408\u308f\u305a\u30a4\u30cb\u30b7\u30e3\u30e9\u30a4\u30ba\u3092\u30d1\u30b9\u3067\u304d\u306a\u3044\u3068\u3044\u3046\u3053\u3068\u3067\u60a9\u307e\u308c\u305f\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u64cd\u4f5c\u65b9\u6cd5\u3082\u307e\u3060\u6d17\u7df4\u3055\u308c\u3066\u304a\u3089\u305a\u3001\u524d\u51e6\u7406\u304c\u9577\u3044\u305f\u3081\u64cd\u4f5c\u306b\u3042\u308b\u7a0b\u5ea6\u306e\u6163\u308c\u304c\u5fc5\u8981\u3067\u3057\u305f\u3002<\/p>\n<h2>\u6210\u9577\u3092\u7d9a\u3051\u305fIon Torrent\u30b7\u30b9\u30c6\u30e0<\/h2>\n<p>2015\u5e74\u3001\u30e9\u30a4\u30d5\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u30ba\u306f\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306b\u52a0\u308f\u308a\u307e\u3059\u3002<\/p>\n<p>\u540c\u5e74\u3001Ion GeneStudio\u2122 S5\u30b7\u30ea\u30fc\u30ba\u304c\u767b\u5834\u3057\u307e\u3059\u3002\u3053\u306e\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u3001\u3053\u308c\u307e\u3067\u306eIon PGM\u30b7\u30fc\u30b1\u30f3\u30b5\u3084Ion Proton\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u4e0d\u4fbf\u306a\u70b9\u3092\u514b\u670d\u3057\u305f\u753b\u671f\u7684\u306a\u88c5\u7f6e\u3067\u3057\u305f\u3002\u7a92\u7d20\u30ac\u30b9\u4e0d\u8981\u3001\u8a66\u85ac\u985e\u306f\u8abf\u88fd\u6e08\u307f\u3067\u4f7f\u3044\u5207\u308a\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u5f0f\u3001\u4f7f\u7528\u5f8c\u306e\u6d17\u6d44\u306f\u81ea\u52d5\u3001\u5b9a\u671f\u7684\u306a\u6d17\u6d44\u3082\u4e00\u5207\u4e0d\u8981\u3002\u8ab0\u3067\u3082\u4e00\u5ea6\u3067\u4f7f\u3044\u65b9\u3092\u899a\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u3061\u306a\u307f\u306b\u3053\u306eS5\u3001\u4f55\u306e\u7565\u304b\u3054\u5b58\u3058\u3067\u3057\u3087\u3046\u304b\u3002 Simple\u3001Speed\u3001Scalable\u3001Small amount of input DNA\u3001Support\u306e\u982d\u6587\u5b57\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p>Ion GeneStudio S5\u30b7\u30ea\u30fc\u30ba\u306f5\u3064\u306eS\u306b\u3082\u3042\u308b\u3088\u3046\u306b\u3001\u975e\u5e38\u306b\u6c4e\u7528\u6027\u306e\u9ad8\u3044\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3059\u3002200\u4e07\uff5e1\u51043,000\u4e07\u30ea\u30fc\u30c9\u3092\u30ab\u30d0\u30fc\u3059\u308b5\u7a2e\u985e\u306e\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u3092\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u3044\u5206\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>Ion GeneStudio S5\u30b7\u30ea\u30fc\u30ba\u306f\u30c7\u30b9\u30af\u30c8\u30c3\u30d7\u578b\u306eIon Torrent\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u5b8c\u6210\u5f62\u3068\u601d\u308f\u308c\u307e\u3057\u305f\u304c\u30012020\u5e74\u3001Ion Torrent\u2122 Genexus\u2122 \u30b7\u30b9\u30c6\u30e0\u304c\u767a\u8868\u3055\u308c\u307e\u3057\u305f\u3002\u3067\u304d\u308b\u3060\u3051\u4eba\u306e\u624b\u3092\u4ecb\u3055\u305a\u306b\u7c21\u4fbf\u306b\u3001\u3068\u3044\u3046\u30b3\u30f3\u30bb\u30d7\u30c8\u3067\u958b\u767a\u3055\u308c\u305fGenexus\u30b7\u30b9\u30c6\u30e0\u306f\u3001Sample to Result\u306e\u30b3\u30f3\u30bb\u30d7\u30c8\u901a\u308a\u306b\u691c\u4f53\u304b\u3089\u30ec\u30dd\u30fc\u30c8\u307e\u3067\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u5b8c\u5168\u81ea\u52d5\u5316\u3057\u3001\u308f\u305a\u304b 2 \u56de\u306e\u30e6\u30fc\u30b6\u30fc\u64cd\u4f5c\u3067\u7d50\u679c\u3092 1 \u65e5\u3067\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3001\u521d\u3081\u3066\u306e\u5b8c\u5168\u81ea\u52d5\u578b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3059<sup>3<\/sup>\u3002SARS-CoV-2\u3082RNA\u3092\u88c5\u7f6e\u5185\u306b\u8a2d\u7f6e\u3059\u308b\u3060\u3051\u3067\u30b7\u30fc\u30b1\u30f3\u30b9\u307e\u3067\u5b9f\u65bd\u3067\u304d\u3001\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u306e\u77e5\u8b58\u306a\u3057\u3067\u682a\u306e\u540c\u5b9a\u3082\u53ef\u80fd\u3067\u3059<sup>4<\/sup>\u3002<\/p>\n<p>\u305d\u3057\u3066\u3001Ion Torrent\u2122 Genexus\u2122 Purification\u30b7\u30b9\u30c6\u30e0\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u6838\u9178\u306e\u62bd\u51fa\u3068\u7cbe\u88fd\u3001\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u304a\u3088\u3073\u89e3\u6790\u7d50\u679c\u30ec\u30dd\u30fc\u30c8\u307e\u3067\u3092\u30b7\u30b9\u30c6\u30e0\u3068\u3057\u3066\u5b9f\u73fe\u3057\u305f\u672c\u5f53\u306e\u610f\u5473\u3067\u306e\u81ea\u52d5\u89e3\u6790\u304c\u53ef\u80fd\u306a\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u4ed5\u4e0a\u304c\u308a\u307e\u3057\u305f\u3002\u30e6\u30fc\u30b6\u30fc\u304c\u64cd\u4f5c\u3059\u308b\u30b9\u30c6\u30c3\u30d7\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u518d\u73fe\u6027\u306e\u9ad8\u3044\u7d50\u679c\u304c\u8ab0\u306b\u3067\u3082\u5f97\u3089\u308c\u308b\u3068\u3044\u3046\u5927\u304d\u306a\u5229\u70b9\u3092\u7372\u5f97\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing\/ion-torrent-next-generation-sequencing-workflow\/ion-torrent-next-generation-sequencing-run-sequence.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_basic_ngs_history_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion Torrent \u30d6\u30e9\u30f3\u30c9\u306e\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5<\/a>\u306f\u4e00\u3064\u306e\u5230\u9054\u70b9\u306b\u305f\u3069\u308a\u7740\u3044\u305f\u3068\u3044\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>\u6b21\u306e10\u5e74\u306f\u3069\u306e\u3088\u3046\u306a\u9032\u5316\u3092\u3059\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u3053\u308c\u304b\u3089\u306eIon Torrent\u30d6\u30e9\u30f3\u30c9\u306b\u305c\u3072\u3054\u671f\u5f85\u304f\u3060\u3055\u3044\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-12058\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/1597907308148-1.png\" alt=\"\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"960\" height=\"615\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/1597907308148-1.png 960w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/1597907308148-1-300x192.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/1597907308148-1-768x492.png 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/p>\n<p>Ion Torrent\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u7814\u7a76\u6210\u679c\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/next-generation-sequencing.html?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_basic_ngs_history_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0 \u307e\u3068\u3081<\/h2>\n<p>\u30fb\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u3067\u30b3\u30b9\u30c8\u30c0\u30a6\u30f3<br \/>\n\u30fb\u30b7\u30f3\u30d7\u30eb\u3055\u3092\u5b9f\u73fe<br \/>\n\u30fb\u30b9\u30d4\u30fc\u30c9\u306e\u8ffd\u6c42<\/p>\n<p>\u30b7\u30f3\u30d7\u30eb\u3067\u30b9\u30d4\u30fc\u30c7\u30a3\u306a\u4f4e\u30b3\u30b9\u30c8\u306eNGS\u306b\u306fIon Torrent\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3092\u305c\u3072\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044<\/p>\n<p>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30d6\u30ed\u30b0\u7279\u96c6 &#8211; \u300cNGS\u89e3\u6790\uff1a\u30ad\u30fc\u30ef\u30fc\u30c9\u89e3\u8aac\u300d\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u60c5\u5831\u3092\u63b2\u8f09\u4e2d\uff08\u65e5\u672c\u8a9e\uff09<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tag\/ngs\/?CID=Csd_cdx_sbu_r04_jp_cp1347_pjt5611_csd00000_0so_blg_op_lgn_kt_s00_basic_ngs_history_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d6\u30ed\u30b0\u3092\u898b\u308b<\/a><\/p>\n<p>\u53c2\u8003\u8ad6\u6587\uff1a<br \/>\n1 An integrated semiconductor device enabling non-optical genome sequencing<br \/>\nJonathan M. Rothberg, Wolfgang Hinz, James Bustillo, et. al.<br \/>\nNature volume 475, pages 348\u2013352 (2011). https:\/\/doi.org\/10.1038\/nature10242<br \/>\n2 Prospective Genomic Characterization of the German Enterohemorrhagic Escherichia coli O104:H4 Outbreak by Rapid Next Generation Sequencing Technology<br \/>\nAlexander Mellmann , Dag Harmsen, Jonathan M. Rothberg, et. al.<br \/>\nPublished: July 20, 2011 https:\/\/doi.org\/10.1371\/journal.pone.0022751<br \/>\n3 Evaluation of Genexus system that automates specimen-to-report for cancer genomic profiling within a day using liquid biopsy.<br \/>\nSiew-Kee Kee Low, Yusuke Nakamura, et. al.<br \/>\nMay 2020Journal of Clinical Oncology 38(15_suppl):3538-3538<br \/>\nDOI:10.1200\/JCO.2020.38.15_suppl.3538<br \/>\n4 SARS-CoV-2 Omicron sublineage BA.2 replaces BA.1.1: genomic surveillance in Japan from September 2021 to March 2022<br \/>\nYosuke Hirotsu, Masao Omata, et. al.<br \/>\ndoi: https:\/\/doi.org\/10.1101\/2022.04.05.22273483<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>2010\u5e74\u306eIon PGM\u2122\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u767b\u5834\u304b\u308912\u5e74\u3002NGS\u3092\u53d6\u308a\u5dfb\u304f\u74b0\u5883\u306f\u3001\u8ab0\u306b\u3082\u4e88\u60f3\u3067\u304d\u306a\u304b\u3063\u305f\u307b\u3069\u306e\u901f\u3055\u3067\u9032\u5316\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eNGS\u30d6\u30e9\u30f3\u30c9\u3067\u3042\u308bIon Torrent\u2122 \u30d6<\/p>\n","protected":false},"author":975,"featured_media":12087,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[165],"division":[],"class_list":{"0":"post-12053","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ngs","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca\" \/>\n<meta property=\"og:description\" content=\"2010\u5e74\u306eIon PGM\u2122\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u767b\u5834\u304b\u308912\u5e74\u3002NGS\u3092\u53d6\u308a\u5dfb\u304f\u74b0\u5883\u306f\u3001\u8ab0\u306b\u3082\u4e88\u60f3\u3067\u304d\u306a\u304b\u3063\u305f\u307b\u3069\u306e\u901f\u3055\u3067\u9032\u5316\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eNGS\u30d6\u30e9\u30f3\u30c9\u3067\u3042\u308bIon Torrent\u2122 \u30d6\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-29T09:13:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-13T02:03:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca\",\"datePublished\":\"2022-06-29T09:13:57+00:00\",\"dateModified\":\"2022-07-13T02:03:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/\"},\"wordCount\":244,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_134698577.jpg\",\"keywords\":[\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/\",\"name\":\"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_134698577.jpg\",\"datePublished\":\"2022-06-29T09:13:57+00:00\",\"dateModified\":\"2022-07-13T02:03:08+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_134698577.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_134698577.jpg\",\"width\":1000,\"height\":667,\"caption\":\"IonTorrentHistory\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_history_gsd_ts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/","og_locale":"ja_JP","og_type":"article","og_title":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca","og_description":"2010\u5e74\u306eIon PGM\u2122\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u767b\u5834\u304b\u308912\u5e74\u3002NGS\u3092\u53d6\u308a\u5dfb\u304f\u74b0\u5883\u306f\u3001\u8ab0\u306b\u3082\u4e88\u60f3\u3067\u304d\u306a\u304b\u3063\u305f\u307b\u3069\u306e\u901f\u3055\u3067\u9032\u5316\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eNGS\u30d6\u30e9\u30f3\u30c9\u3067\u3042\u308bIon Torrent\u2122 \u30d6","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-06-29T09:13:57+00:00","article_modified_time":"2022-07-13T02:03:08+00:00","og_image":[{"width":1000,"height":667,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca","datePublished":"2022-06-29T09:13:57+00:00","dateModified":"2022-07-13T02:03:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/"},"wordCount":244,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","keywords":["\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/","name":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","datePublished":"2022-06-29T09:13:57+00:00","dateModified":"2022-07-13T02:03:08+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","width":1000,"height":667,"caption":"IonTorrentHistory"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_history_gsd_ts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"Ion Torrent\u2122 \u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u59cb\u307e\u308a\u3068\u4eca"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":165,"label":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":165,"name":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5","slug":"ngs","term_group":0,"term_taxonomy_id":165,"taxonomy":"post_tag","description":"","parent":0,"count":71,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":12053,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":12053,"position":1},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":12053,"position":2},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":12053,"position":3},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":12053,"position":4},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":12053,"position":5},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_134698577.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12053"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12053\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12087"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12053"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12053"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12053"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}