{"id":12095,"date":"2022-07-01T17:04:47","date_gmt":"2022-07-01T08:04:47","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12095"},"modified":"2022-08-12T11:46:17","modified_gmt":"2022-08-12T02:46:17","slug":"agrigenomics_ngs_gsd_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/","title":{"rendered":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13"},"content":{"rendered":"<p>\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u3068\u755c\u7523\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u95a2\u4fc2\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<br \/>\n\u4eca\u56de\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u305f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u6539\u826f\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>ICBF\u306eAxiom\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30a2\u30ec\u30a4\u3092\u7528\u3044\u305f\u53d6\u308a\u7d44\u307f<\/h2>\n<p>\u30b2\u30ce\u30df\u30af\u30b9\u6280\u8853\u306f\u3001\u5927\u304d\u306a\u554f\u984c\u3092\u89e3\u6c7a\u3057\u3001\u4eca\u65e5\u3067\u306f\u4e0d\u53ef\u80fd\u306b\u601d\u3048\u308b\u52d5\u7269\u7e41\u6b96\u306e\u65b0\u3057\u3044\u30d1\u30e9\u30c0\u30a4\u30e0\u3092\u78ba\u7acb\u3059\u308b\u53ef\u80fd\u6027\u3092\u79d8\u3081\u3066\u3044\u307e\u3059\u3002<br \/>\n\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u755c\u7523\u7d44\u7e54\u3068\u8fb2\u5bb6\u306e\u5354\u540c\u7d44\u5408\u3067\u3042\u308b<a href=\"https:\/\/www.icbf.com\/\" target=\"_blank\" rel=\"noopener\">ICBF<\/a>\uff08Irish Cattle Breeding Federation\uff09\u306f\u305d\u306e\u5b9f\u73fe\u3092\u8a93\u3063\u305f\u30b0\u30eb\u30fc\u30d7\u306e\u4e00\u3064\u3067\u3059\u3002ICBF\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\u3067\u3042\u308b\u30a2\u30f3\u30c9\u30ea\u30e5\u30fc \u30af\u30ed\u30df\u30fc\u535a\u58eb\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u4e73\u725b\u3068\u8089\u725b\u306e\u907a\u4f1d\u7684\u6539\u5584\u3092\u4e3b\u306a\u76ee\u7684\u3068\u3057\u3066\u3001\u30b2\u30ce\u30df\u30af\u30b9\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3066\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u5927\u898f\u6a21\u907a\u4f1d\u5b50\u578b\u5224\u5b9a\u3092\u76e3\u4fee\u3057\u307e\u3057\u305f\u3002<\/p>\n<p><iframe loading=\"lazy\" title=\"Genetic improvement of dairy and beef cattle in Ireland\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/IixzVLXCm58?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p>ICBF\u306f\u73fe\u5728\u3001\u6700\u5148\u7aef\u306e\u30c4\u30fc\u30eb\u3067\u3042\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs\/axiom-genotyping-solution-agrigenomics.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_agrigenomics_ngs_gsd_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems \u2122Axiom\u2122 \u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30d7\u30e9\u30c3\u30c8\u30d5\u30a9\u30fc\u30e0<\/a>\u3092\u7528\u3044\u3066\u3001\u4e00\u6bb5\u4e0a\u306e\u30ec\u30d9\u30eb\u306b\u6539\u826f\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u30c7\u30fc\u30bf\u3092\u53ce\u96c6\u3057\u3066\u3044\u307e\u3059\u3002\u30af\u30ed\u30df\u30fc\u535a\u58eb\u306f\u300c\u30b2\u30ce\u30df\u30af\u30b9\u306f\u3001\u5e83\u5927\u306a\u725b\u96c6\u56e3\u306b\u305d\u306e\u7279\u6027\u3092\u5e83\u3081\u308b\u4fa1\u5024\u306e\u3042\u308b\u907a\u4f1d\u7684\u5916\u308c\u5024\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u79c1\u305f\u3061\u304c\u76ee\u6307\u3059\u907a\u4f1d\u7684\u7372\u5f97\u91cf\u3078\u306e\u5230\u9054\u3092\u52a0\u901f\u3055\u305b\u308b\u305f\u3081\u306e\u91cd\u8981\u306a\u30c4\u30fc\u30eb\u3067\u3059\u300d\u3068\u8a71\u3057\u307e\u3059\u3002\u82e5\u3044\u3068\u7279\u5b9a\u3055\u308c\u305f\u5834\u5408\u3001\u3053\u306e\u725b\u306f\u4eca\u5f8c\u306e\u54c1\u7a2e\u6539\u826f\u3078\u306e\u7126\u70b9\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u65e9\u671f\u306e\u8b58\u5225\u306b\u3088\u308a\u65e9\u671f\u5bfe\u5fdc\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u8fb2\u5bb6\u306f\u3053\u308c\u307e\u3067\u306e\u65b9\u6cd5\u3088\u308a\u3082\u683c\u6bb5\u306b\u77ed\u671f\u9593\u3067\u3001\u76ee\u7684\u306e\u5f62\u8cea\u304c\u3069\u308c\u3060\u3051\u52b9\u679c\u7684\u306b\u4f1d\u64ad\u3057\u3066\u3044\u308b\u304b\u3092\u5224\u65ad\u3067\u304d\u307e\u3059\u3002ICBF\u306f\u3001\u8089\u7528\u725b\u5411\u3051\u306e\u5927\u898f\u6a21\u306a\u30d7\u30ed\u30b0\u30e9\u30e0\u3068\u4e73\u725b\u5411\u3051\u306e\u958b\u767a\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u8d70\u3089\u305b\u3066\u304a\u308a\u3001\u3053\u308c\u3089\u306e\u907a\u4f1d\u5b50\u7372\u5f97\u3092\u52a0\u901f\u3059\u308b\u305f\u3081\u306b\u5927\u898f\u6a21\u306e\u30b2\u30ce\u30e0\u60c5\u5831\u3092\u53ce\u96c6\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306b\u304a\u3051\u308b\u30b2\u30ce\u30df\u30af\u30b9\u306e\u755c\u7523\u696d\u3078\u306e\u5fdc\u7528\u3068\u30e1\u30bf\u30f3\u6392\u51fa\u91cf\u524a\u6e1b<\/h2>\n<p>\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306f\u3001\u56fd\u5185\u6d88\u8cbb\u91cf\u306e10\u500d\u306e\u725b\u3092\u751f\u7523\u3057\u3001\u751f\u7523\u91cf\u306e90\uff05\u3092\u4e3b\u306b\u82f1\u56fd\u3001\u6b27\u5dde\u304a\u3088\u3073\u30a2\u30b8\u30a2\u306b\u8f38\u51fa\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u755c\u7523\u898f\u6a21\u306e\u58ee\u5927\u3055\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u7dcf\u6392\u51fa\u91cf\u306e\u7d0433\uff05\u3092\u4e3b\u306b\u725b\u304b\u3089\u306e\u30e1\u30bf\u30f3\u3067\u7523\u51fa\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3082\u7406\u89e3\u3067\u304d\u307e\u3059\u3002\u305d\u3057\u3066ICBF\u306f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u725b\u306e\u30e1\u30bf\u30f3\u6392\u51fa\u91cf\u3092\u6e1b\u3089\u3059\u53ef\u80fd\u6027\u306e\u3042\u308b\u907a\u4f1d\u7684\u6539\u826f\u3092\u6a21\u7d22\u3057\u3066\u3044\u307e\u3059\u3002\u30af\u30ed\u30df\u30fc\u535a\u58eb\u306f\u3001\u3053\u308c\u306f\u30e1\u30bf\u30f3\u751f\u6210\u91cf\u304c\u5c11\u306a\u3044\u52d5\u7269\u3092\u7e41\u6b96\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3092\u898b\u6975\u3081\u308b\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u4e3b\u8981\u306a\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u3067\u3042\u308b\u3068\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u5bb6\u755c\u306b\u3088\u308b\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u6392\u51fa\u91cf\u306f\u524a\u6e1b\u3092\u9054\u6210\u3067\u304d\u308b\u5206\u91ce\u3060\u3068\u898b\u306a\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3059\u3002ICBF\u30c1\u30fc\u30e0\u306f\u3001Applied Biosystems\u2122 Axiom\u2122 myDesign Array\u3092\u5229\u7528\u3057\u3066\u3001\u755c\u7523\u306e\u6c17\u5019\u7684\u30fb\u74b0\u5883\u7684\u5f71\u97ff\u306b\u95a2\u9023\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u5f62\u8cea\u60c5\u5831\u3092\u96c6\u7d04\u3059\u308b\u3068\u5171\u306b\u3001\u4e8c\u9178\u5316\u70ad\u7d20\u6392\u51fa\u91cf\u3092\u524a\u6e1b\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u512a\u308c\u305f\u52d5\u7269\u3068\u305d\u306e\u5f62\u8cea\u3092\u7279\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u5c06\u6765\u306e\u76ee\u6a19\u306f\u4f55\u3067\u3059\u304b\uff1f<\/h2>\n<p>ICBF\u306e\u76ee\u6a19\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u3059\u3079\u3066\u306e\u725b\u3092\u907a\u4f1d\u5b50\u578b\u5224\u5b9a\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u5b8c\u5168\u306b\u907a\u4f1d\u5b50\u578b\u5224\u5b9a\u3055\u308c\u305f\u96c6\u56e3\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u3001\u8ffd\u8de1\u53ef\u80fd\u6027\u3068\u51fa\u81ea\u306e\u30c7\u30fc\u30bf\u304c\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u3001\u524d\u4f8b\u306e\u306a\u3044\u30ec\u30d9\u30eb\u3067\u306e\u54c1\u8cea\u7ba1\u7406\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u5b8c\u5168\u306b\u907a\u4f1d\u5b50\u578b\u5224\u5b9a\u3055\u308c\u305f\u725b\u7fa4\u306f\u3001\u907a\u4f1d\u7684\u7372\u5f97\u91cf\u3092\u672a\u77e5\u306e\u30ec\u30d9\u30eb\u307e\u3067\u6700\u5927\u5316\u3057\u3066\u54c1\u7a2e\u6539\u826f\u3092\u5b9f\u65bd\u3057\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u725b\u7fa4\u5168\u4f53\u306e\u907a\u4f1d\u7684\u80cc\u666f\u3092\u660e\u3089\u304b\u306b\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u306f\u3001\u7814\u7a76\u8005\u3068\u30d6\u30ea\u30fc\u30c0\u30fc\u306e\u4e21\u65b9\u306b\u3068\u3063\u3066\u5927\u304d\u306a\u6069\u6075\u3068\u306a\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n<h2>\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eICBF\u306e\u53d6\u308a\u7d44\u307f\u3078\u306e\u652f\u63f4<\/h2>\n<p>\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u305f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u3067\u306e\u725b\u30b2\u30ce\u30df\u30af\u30b9\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u3092\u901a\u3058\u3066\u3001ICBF\u306f\u3053\u308c\u307e\u3067\u306b\u7d04200\u4e07\u982d\u306e\u907a\u4f1d\u5b50\u578b\u3092\u7279\u5b9a\u3057\u307e\u3057\u305f\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u304b\u3089\u306e\u76f4\u63a5\u306e\u30b5\u30dd\u30fc\u30c8\u306e\u5143\u3001Axiom Genotyping Array\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001ICBF\u306f\u6700\u521d\u306e1\u5e74\u9593\u306730\u4e07\u982d\u4ee5\u4e0a\u306e\u52d5\u7269\u306e\u907a\u4f1d\u5b50\u578b\u3092\u7279\u5b9a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5f53\u793e\u3068\u7dca\u5bc6\u306b\u9023\u643a\u3057\u3066\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u3055\u308c\u305fBovine Array\u3092\u7528\u3044\u30662\u56de\u76ee\u306e\u53cd\u5fa9\u30c6\u30b9\u30c8\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002<br \/>\nICBF\u306f\u4eca\u5e74\u3082\u540c\u69d8\u306e\u53ce\u7a6b\u91cf\u3092\u671f\u5f85\u3057\u3066\u304a\u308a\u3001\u30c6\u30b9\u30c8\u7d50\u679c\u3092\u5e74\u9593250\u4e07\u982d\u306b\u5897\u3084\u3059\u3053\u3068\u3067\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u5168\u4f53\u306e\u725b\u306e\u907a\u4f1d\u5b50\u578b\u5224\u5b9a\u5b8c\u4e86\u3092\u9054\u6210\u3059\u308b\u3053\u3068\u3092\u671f\u5f85\u3057\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u3068\u306e\u7dca\u5bc6\u3067\u7d99\u7d9a\u7684\u306a\u9023\u643a\u306b\u3088\u308a\u3001\u30af\u30ed\u30df\u30fc\u535a\u58eb\u3068\u305d\u306e\u30c1\u30fc\u30e0\u306f\u3001\u3053\u308c\u3089\u306e\u76ee\u6a19\u304c\u9054\u6210\u53ef\u80fd\u3067\u3042\u308a\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u725b\u7523\u696d\u306b\u5341\u5206\u306b\u671f\u5f85\u3055\u308c\u305f\u7d50\u679c\u3092\u8fd4\u3059\u3053\u3068\u304c\u3067\u304d\u308b\u3068\u78ba\u4fe1\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>Applied Biosystems\u2122\u306eAgrigenomics\u306e\u88fd\u54c1\u3068\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<br \/>\n\u5f53\u793e\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/microarray-analysis\/agrigenomics-solutions-microarrays-gbs\/axiom-genotyping-solution-agrigenomics.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_agrigenomics_ngs_gsd_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Web\u30da\u30fc\u30b8<\/a>\u306b\u30a2\u30af\u30bb\u30b9\u304f\u3060\u3055\u3044\u3002<br \/>\nAxiom\u725b\u30a2\u30ec\u30a4\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Applied Biosystems\u2122 Axiom Bovine Genotyping v3 Array\uff08384\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff09\u3001Applied Biosystems\u2122 Axiom Bovine Genotyping v3 Array\uff08mini-96\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff09\u3001<br \/>\n\u304a\u3088\u3073Applied Biosystems\u2122 Axiom Genome-Wide BOS 1Bovine Array\u306e\u8a73\u7d30\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002\u52d5\u7269\u30b2\u30ce\u30df\u30af\u30b9\u88fd\u54c1\u306eAgriSeq\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/agricultural-biotechnology\/agrigenomics\/agriseq-targeted-genotyping-sequencing.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_agrigenomics_ngs_gsd_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Axiom\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3084AgriSeq GBS\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u5f53\u793e\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/inquiry-reagents.html?CID=Gsd_agr_anh_r04_jp_cp1355_pjt5725_gsd00000_0so_blg_op_lgn_kt_s00_agrigenomics_ngs_gsd_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>ICBF\u306f\u755c\u7523\u725b\u7531\u6765\u306e\u30e1\u30bf\u30f3\u6392\u51fa\u91cf\u3092\u524a\u6e1b\u3059\u308b\u305f\u3081\u306e\u907a\u4f1d\u7684\u6539\u826f\u3092Applied Biosystems Axiom Array\u3092\u7528\u3044\u3066\u53d6\u308a\u7d44\u3093\u3067\u3044\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u3068\u755c\u7523\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u95a2\u4fc2\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f \u4eca\u56de\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u305f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u6539\u826f\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 ICBF\u306eAxiom\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30a2\u30ec\u30a4\u3092\u7528\u3044<\/p>\n","protected":false},"author":975,"featured_media":12426,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":{"0":"post-12095","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13\" \/>\n<meta property=\"og:description\" content=\"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u3068\u755c\u7523\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u95a2\u4fc2\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f \u4eca\u56de\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u305f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u6539\u826f\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 ICBF\u306eAxiom\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30a2\u30ec\u30a4\u3092\u7528\u3044\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-07-01T08:04:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-12T02:46:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13\",\"datePublished\":\"2022-07-01T08:04:47+00:00\",\"dateModified\":\"2022-08-12T02:46:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/\"},\"wordCount\":74,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1855312099.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/\",\"name\":\"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1855312099.jpg\",\"datePublished\":\"2022-07-01T08:04:47+00:00\",\"dateModified\":\"2022-08-12T02:46:17+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1855312099.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1855312099.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/agrigenomics_ngs_gsd_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13","og_description":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u3068\u755c\u7523\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u95a2\u4fc2\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f \u4eca\u56de\u306f\u3001\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u306e\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u305f\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u6539\u826f\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 ICBF\u306eAxiom\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u30a2\u30ec\u30a4\u3092\u7528\u3044","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-07-01T08:04:47+00:00","article_modified_time":"2022-08-12T02:46:17+00:00","og_image":[{"width":1000,"height":667,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13","datePublished":"2022-07-01T08:04:47+00:00","dateModified":"2022-08-12T02:46:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/"},"wordCount":74,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/","name":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","datePublished":"2022-07-01T08:04:47+00:00","dateModified":"2022-08-12T02:46:17+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agrigenomics_ngs_gsd_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u306e\u524a\u6e1b\u306b\u5411\u3051\u3066\uff1a\u30a2\u30a4\u30eb\u30e9\u30f3\u30c9\u725b\u306e\u907a\u4f1d\u5b50\u8a66\u9a13"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":24122,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gene-therapy-purification-affinity-chromatography-bpg-25072\/","url_meta":{"origin":12095,"position":0},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u907a\u4f1d\u5b50\u6cbb\u7642\u306b\u304a\u3051\u308b\u7cbe\u88fd\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670826\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u907a\u4f1d\u5b50\u6cbb\u7642\u306e\u6025\u901f\u306a\u767a\u5c55\u306b\u3088\u308a\u3001\u6cbb\u7642\u6cd5\u306e\u958b\u767a\u3068\u5b9f\u7528\u5316\u306b\u5411\u3051\u305f\u53d6\u308a\u7d44\u307f\u304c\u6d3b\u767a\u5316\u3057\u3066\u3044\u307e\u3059\u3002 \u672c\u30d6\u30ed\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-bpg-25072_eycatch.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":12095,"position":1},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25200,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-battery-manufacturing-csm-26019\/","url_meta":{"origin":12095,"position":2},"title":"BTRY\u793e \u306e\u5168\u56fa\u4f53\u96fb\u6c60\u6280\u8853\u3068\u96fb\u6c17\u81ea\u52d5\u8eca\u5411\u3051\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u3078\u306e\u53ef\u80fd\u6027 BTRY AG\u5171\u540c\u5275\u696d\u8005 \u517c CEO Moritz Futscher\u6c0f\u3078\u306e\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","author":"LatB Staff","date":"2026\u5e745\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aBTRY\u2019s solid state battery technology and i\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/battery-development-battery-manufacturing-csm-26019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":12095,"position":3},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24707,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-csm-26009\/","url_meta":{"origin":12095,"position":4},"title":"\u96fb\u6c60\u88fd\u9020\u306b\u5411\u3051\u305f\u591a\u5c64\u96fb\u6975\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6280\u8853\u306e\u9032\u5c55","author":"LatB Staff","date":"2026\u5e742\u670824\u65e5","format":false,"excerpt":"\u9ad8\u5ea6\u306a\u96fb\u6975\u8a2d\u8a08\u3068\u3001\u305d\u308c\u304c\u96fb\u6c60\u96fb\u6975\u306e\u6027\u80fd\u304a\u3088\u3073\u52b9\u7387\u306b\u4e0e\u3048\u308b\u5f71\u97ff8inks \u5171\u540c\u5275\u696d\u8005\u517c CEO Dr.\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":12095,"position":5},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1855312099.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12095"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12095\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12426"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12095"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12095"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12095"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}