{"id":12296,"date":"2022-08-01T10:44:43","date_gmt":"2022-08-01T01:44:43","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12296"},"modified":"2025-05-28T13:57:50","modified_gmt":"2025-05-28T04:57:50","slug":"protein-basic24_bid_ts","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/","title":{"rendered":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f"},"content":{"rendered":"<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic4\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u524d\u56de\u306e\u30d6\u30ed\u30b0<\/a>\u3067\u306f\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3088\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u767a\u8272\u6cd5\uff08BCA\u6cd5\u3001Bradford\u6cd5\u3001<br \/>\nLowry\u6cd5\u3001Pierce 660 nm\u6cd5\uff09\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>\u3053\u308c\u3089\u767a\u8272\u6cd5\u4ee5\u5916\u306b\u3082\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3001UV\u6cd5\u3084\u86cd\u5149\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002UV\u6cd5\u306f\u6700\u3082\u7c21\u4fbf\u306a\u65b9\u6cd5\u3067\u3001\u86cd\u5149\u6cd5\u306f\u4e00\u822c\u7684\u306b\u9ad8\u3044\u611f\u5ea6\u3067\u5b9a\u91cf\u304c\u884c\u3048\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n<p>\u3067\u306f\u3001\u306a\u305cUV\u6cd5\u304c\u4e00\u756a\u7c21\u5358\u306a\u306e\u306b\u767a\u8272\u6cd5\u304c\u3088\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u307e\u305f\u3001\u611f\u5ea6\u304c\u9ad8\u3044\u86cd\u5149\u6cd5\u306b\u306f\u3069\u3093\u306a\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u305d\u3057\u3066\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5b9a\u91cf\u6cd5\u306b\u306f\u3053\u308c\u3060\u3051\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u7d50\u5c40\u3069\u306e\u65b9\u6cd5\u304c\u826f\u3044\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n<p>\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001UV\u6cd5\u3084\u86cd\u5149\u6cd5\u306e\u539f\u7406\u3084\u30e1\u30ea\u30c3\u30c8\u3084\u30c7\u30e1\u30ea\u30c3\u30c8\u306e\u307b\u304b\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e<br \/>\n\u9078\u3073\u65b9\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>UV\u6cd5\uff1a\u3068\u306b\u304b\u304f\u7c21\u5358<\/h2>\n<p>UV\u6cd5\u306f\u3001\u540d\u524d\u306e\u3068\u304a\u308a\u3001\u7d2b\u5916\u6ce2\u9577\u3067\u3042\u308b280 nm\u3067\u5438\u5149\u5ea6\u3092\u6e2c\u5b9a\u3057\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u5b9a\u91cf\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12335\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg\" alt=\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\" width=\"1000\" height=\"667\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg 1000w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919-96x65.jpg 96w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><br \/>\n\u6ce2\u9577\u304c280 nm\u306a\u306e\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u69cb\u6210\u3059\u308b\u30a2\u30df\u30ce\u9178\u306e\u3046\u3061\u3001\u82b3\u9999\u65cf\u30a2\u30df\u30ce\u9178\u3067\u3042\u308b\u30c1\u30ed\u30b7\u30f3\u3084\u30c8\u30ea\u30d7\u30c8\u30d5\u30a1\u30f3\u306a\u3069\u306b\u3001\u3053\u306e\u6ce2\u9577\u306e\u5149\u3092\u5438\u53ce\u3059\u308b\u6027\u8cea\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002\u30bf\u30f3\u30d1\u30af\u8cea\u306f205 nm\u4ed8\u8fd1\u306b\u3082\u30da\u30d7\u30c1\u30c9\u7d50\u5408\u7531\u6765\u306e\u5438\u53ce\u304c\u3042\u308a\u307e\u3059\u304c\u3001205 nm\u4ed8\u8fd1\u306f\u591a\u304f\u306e\u7269\u8cea\u304c\u5438\u53ce\u3092\u6301\u3064\u305f\u3081\u3001205 nm\u3088\u308a\u306f\u5438\u53ce\u3092\u6301\u3064\u7269\u8cea\u304c\u5c11\u306a\u3044280 nm\u3067\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><b>\u539f\u7406<\/b><br \/>\n\u30fb\u82b3\u9999\u65cf\u30a2\u30df\u30ce\u9178\u304c280 nm\u306e\u6ce2\u9577\u3092\u5438\u53ce\u3059\u308b\u6027\u8cea\u3092\u5229\u7528<br \/>\n<b>\u30e1\u30ea\u30c3\u30c8<\/b><br \/>\n\u30fb\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306e\u307e\u307e\u6e2c\u5b9a\u3067\u304d\u308b\u305f\u3081\u3001\u3068\u306b\u304b\u304f\u7c21\u5358<br \/>\n\u30fb\u8a66\u85ac\u306a\u3069\u3092\u8cfc\u5165\u3059\u308b\u5fc5\u8981\u304c\u306a\u304f\u3001\u5b89\u4fa1<br \/>\n\u30fb\u6e2c\u5b9a\u306b\u3088\u308b\u6d3b\u6027\u4f4e\u4e0b\u304c\u306a\u3044\u305f\u3081\u3001\u6e2c\u5b9a\u5f8c\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u56de\u53ce\u3067\u304d\u308b<br \/>\n<b>\u30c7\u30e1\u30ea\u30c3\u30c8<\/b><br \/>\n\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u82b3\u9999\u65cf\u30a2\u30df\u30ce\u9178\u306e\u6570\u304c\u7570\u306a\u308b\u305f\u3081\u3001\u5438\u5149\u5ea6\u304c\u7570\u306a\u308b<br \/>\n\u30fb\u611f\u5ea6\u304c\u4f4e\u3044\uff0850 \u03bcg\uff5e2 mg\/mL\u7a0b\u5ea6\uff09<br \/>\n\u30fb280 nm\u306b\u5438\u53ce\u3092\u6301\u305f\u306a\u3044\u30bf\u30f3\u30d1\u30af\u8cea\uff08\u30b3\u30e9\u30fc\u30b2\u30f3\u3001\u30bc\u30e9\u30c1\u30f3\u306a\u3069\uff09\u304c\u5b58\u5728\u3059\u308b<br \/>\n\u30fb\u6838\u9178\u3084\u30a2\u30df\u30ce\u9178\u306a\u3069\u3001280 nm\u306b\u5438\u53ce\u304c\u3042\u308b\u7269\u8cea\u306e\u5438\u5149\u5ea6\u3082\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u3001<br \/>\n\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u7cbe\u88fd\u3055\u308c\u3066\u3044\u308b\u306e\u304c\u671b\u307e\u3057\u3044<\/p>\n<p>UV\u6cd5\u3067\u306f\u3001\u300c\u5438\u5149\u4fc2\u6570\u300d\u3092\u7528\u3044\u308bLambert-Beer\u306e\u6cd5\u5247\u304b\u3089\u30bf\u30f3\u30d1\u30af\u8cea\u6fc3\u5ea6\u3092\u8a08\u7b97\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12313\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429-1024x113.png\" alt=\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\" width=\"760\" height=\"84\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429-1024x113.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429-300x33.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429-768x85.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429-1536x169.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/cbf5b9f60da99bf791c0aa12a770f429.png 1851w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u5438\u5149\u4fc2\u6570\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u3001\u4f8b\u3048\u3070BSA\u3067\u306f\u7d046.7\u3067\u3059\u3002\u5149\u8def\u957710 mm\u306e\u30bb\u30eb\u3092\u7528\u3044\u305f\u5834\u5408\u3001\u4e0a\u306e\u5f0f\u306b\u3042\u3066\u306f\u3081\u308b\u3068\u3001280 nm\u306b\u304a\u3051\u308b\u5438\u5149\u5ea6\u304c1.0\u306e\u3068\u304d\u3001BSA\u306e\u6fc3\u5ea6\u306fc\uff1d1.0 \/ 6.7\u00d710\uff1d\u7d041.5 mg\/mL\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>BSA\u306e\u3088\u3046\u306b\u3088\u304f\u77e5\u3089\u308c\u3066\u3044\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3042\u308c\u3070\u3001\u8abf\u3079\u308c\u3070\u5438\u5149\u4fc2\u6570\u306f\u308f\u304b\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u5438\u5149\u4fc2\u6570\u304c\u4e0d\u660e\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u3082\u591a\u304f\u3001\u3055\u3089\u306b\u3069\u3093\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u3069\u306e\u304f\u3089\u3044\u542b\u307e\u308c\u3066\u3044\u308b\u304b\u308f\u304b\u3089\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u5438\u5149\u4fc2\u6570\u3092\u3042\u3066\u306f\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n<p>\u3057\u304b\u3057\u3001\u8907\u6570\u542b\u307e\u308c\u3066\u3044\u308b\u30b5\u30f3\u30d7\u30eb\u3060\u304b\u3089\u3053\u305d\u3001\u5c0f\u3055\u3044\u5438\u5149\u4fc2\u6570\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3082\u3001\u5927\u304d\u3044\u5438\u5149\u4fc2\u6570\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3082\u542b\u307e\u308c\u3066\u3044\u308b\u3068\u8a00\u3048\u307e\u3059\u3002\u3088\u3063\u3066\u3001\u300c280 nm\u306b\u304a\u3051\u308b\u5438\u5149\u5ea6\u304c1.0\u306e\u3068\u304d\u306f1.0 mg\/mL\u306b\u3057\u3066\u3057\u307e\u3046\u300d\u3053\u3068\u3067\u3001\u3056\u3063\u304f\u308a\u3068\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6fc3\u5ea6\u3092\u6c7a\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u306a\u304a\u3001\u3053\u3053\u3067\u3082\u30461\u70b9\u6ce8\u610f\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u306e\u306f\u3001280 nm\u306e\u5438\u53ce\u3092\u6301\u3063\u3066\u3044\u308b\u7269\u8cea\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u3060\u3051\u3067\u306f\u306a\u3044\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u6838\u9178\u3084\u30a2\u30df\u30ce\u9178\u3001\u307b\u304b\u306b\u3082280 nm\u306b\u5438\u53ce\u3092\u6301\u3064\u7269\u8cea\u306f\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001280 nm\u306e\u5438\u5149\u5ea6\u304c\u9ad8\u3044\u304b\u3089\u300c\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u305f\u304f\u3055\u3093\u542b\u307e\u308c\u3066\u3044\u308b\uff01\u300d\u3068\u601d\u3063\u3066\u3082\u3001\u5b9f\u306f\u898b\u3066\u3044\u305f\u306e\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u306f\u306a\u3044\u5225\u306e\u7269\u8cea\u3060\u3063\u305f\u3001\u306a\u3093\u3066\u3053\u3068\u3082\u3042\u308a\u5f97\u307e\u3059<sup>\u203b<\/sup>\u3002\u3053\u3046\u3044\u3063\u305f\u70b9\u304b\u3089\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066UV\u6cd5\u3088\u308a\u3082\u7cbe\u5ea6\u306e\u9ad8\u3044\u767a\u8272\u6cd5\u3092\u9078\u3070\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u306e\u3067\u3059\u3002<br \/>\n<span style=\"font-size: small\">\u203b\u305f\u3068\u3048\u3070\u3001A280\/A260 &lt;1.5 \u306e\u3068\u304d\u306f\u6838\u9178\u306e\u6df7\u5165\u304c\u8003\u3048\u3089\u308c\u308b\u306e\u3067\u3001\u307b\u304b\u306e\u65b9\u6cd5\u3092\u691c\u8a0e\u3057\u307e\u3057\u3087\u3046\u3002<\/span><\/p>\n<p>\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306e\u30c7\u30e1\u30ea\u30c3\u30c8\u3092\u5dee\u3057\u5f15\u3044\u3066\u3082UV\u6cd5\u306b\u306f\u5927\u304d\u306a\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u306f\u3001\u3068\u306b\u304b\u304f\u6e2c\u5b9a\u304c\u7c21\u5358\u306a\u70b9\u3002\u4f55\u3057\u308d\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/ultraviolet-visible-visible-spectrophotometry-uv-vis-vis\/uv-vis-vis-instruments\/nanodrop-microvolume-spectrophotometers.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 NanoDrop\u2122 One\/OneC\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08<\/a>\u306a\u3069\u306e\u5206\u5149\u5149\u5ea6\u8a08\u3067\u30b5\u30f3\u30d7\u30eb\u306e280 nm\u306e\u5438\u5149\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3060\u3051\u3067\u5b9a\u91cf\u304c\u3067\u304d\u308b\u306e\u3067\u3059\u3002\u8a66\u85ac\u3092\u8cfc\u5165\u3059\u308b\u5fc5\u8981\u306f\u306a\u304f\u3001\u7279\u5225\u306a\u624b\u6280\u3082\u3044\u308a\u307e\u305b\u3093\u3002\u306a\u304a\u3001NanoDrop One\/Onec\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3067\u3042\u308c\u3070\u3001Acclaro\uff08\u30a2\u30af\u30e9\u30ed\uff09\u3068\u3044\u3046\u6a5f\u80fd\u3067\u3001280 nm\u3067\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6e2c\u5b9a\u3057\u305f\u3068\u304d\u3001\u6838\u9178\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u304c\u4e88\u6e2c\u3055\u308c\u308b\u5834\u5408\u306f\u30a2\u30e9\u30fc\u30c8\u3092\u51fa\u3059\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u3001\u3053\u306e\u6e2c\u5b9a\u306b\u3088\u3063\u3066\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6d3b\u6027\u3092\u640d\u306d\u308b\u3053\u3068\u306f\u4e00\u822c\u7684\u306b\u306a\u3044\u306e\u3067\u3001\u6e2c\u5b9a\u5f8c\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u56de\u53ce\u3067\u304d\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u88c5\u7f6e\u3068\u5438\u5149\u5ea6\u6e2c\u5b9a\u88c5\u7f6e\u3092\u9023\u7d50\u3055\u305b\u3066\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u6eb6\u51fa\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3057\u306a\u304c\u3089\u5206\u53d6\u3082\u3067\u304d\u307e\u3059\u3002\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u3064\u3064\u30e1\u30ea\u30c3\u30c8\u3082\u5927\u304d\u3044\u306e\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5fdc\u3058\u3066\u305c\u3072\u6d3b\u7528\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>\u86cd\u5149\u6cd5\uff1a\u611f\u5ea6\u304c\u9ad8\u3044<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12337\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_372894448.jpg\" alt=\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\" width=\"1000\" height=\"667\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_372894448.jpg 1000w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_372894448-300x200.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_372894448-768x512.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_372894448-96x65.jpg 96w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p>\u86cd\u5149\u6cd5\u306f\u3001\u86cd\u5149\u8272\u7d20\u3084\u539f\u7406\u306b\u3088\u3063\u3066\u3055\u307e\u3056\u307e\u306a\u7279\u5fb4\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4e00\u822c\u7684\u306b\u3001\u611f\u5ea6\u304c\u9ad8\u3044\u5b9a\u91cf\u6cd5\u3067\u3059\u3002<br \/>\n\u611f\u5ea6\u304c\u9ad8\u3044\u3053\u3068\u306f\u3001\u308f\u305a\u304b\u3057\u304b\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u3067\u3082\u5b9a\u91cf\u304c\u3067\u304d\u308b\u3068\u3044\u3046\u5927\u304d\u306a\u30e1\u30ea\u30c3\u30c8\u3092\u751f\u307f\u307e\u3059\u3002<\/p>\n<p><b>\u539f\u7406<\/b><br \/>\n\u30fb\u86cd\u5149\u8a66\u85ac\u306b\u3088\u3063\u3066\u3055\u307e\u3056\u307e<br \/>\n<b>\u30e1\u30ea\u30c3\u30c8<\/b><br \/>\n\u30fb\u611f\u5ea6\u304c\u9ad8\u3044<br \/>\n\u30fb\u7814\u7a76\u5ba4\u306b\u3042\u308b\u6a5f\u5668\u3084\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u308f\u305b\u3066\u86cd\u5149\u8a66\u85ac\u3092\u9078\u3076\u3053\u3068\u304c\u3067\u304d\u308b<br \/>\n<b>\u30c7\u30e1\u30ea\u30c3\u30c8<\/b><br \/>\n\u30fb\u86cd\u5149\u691c\u51fa\u5668\u3084\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc\u304c\u5fc5\u8981<br \/>\n\u30fb\u86cd\u5149\u8a66\u85ac\u3084\u65b9\u6cd5\u306b\u3088\u3063\u3066\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u914d\u5217\u4f9d\u5b58\u6027\u304c\u3042\u308b<br \/>\n\uff08\u7b2c\u4e00\u7d1a\u30a2\u30df\u30f3\u306b\u7d50\u5408\u3059\u308b\u86cd\u5149\u8a66\u85ac\u306a\u3069\uff09<\/p>\n<p>\u86cd\u5149\u6cd5\u3067\u5b9a\u91cf\u3059\u308b\u306b\u306f\u3001\u86cd\u5149\u691c\u51fa\u5668\u3084\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc\u304c\u5fc5\u8981\u3067\u3059\u3002\u3072\u3068\u6614\u524d\u306f\u9ad8\u984d\u306a\u5927\u578b\u6a5f\u5668\u304c\u591a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u73fe\u5728\u306f\u6301\u3061\u904b\u3073\u3067\u304d\u308b\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u30b5\u30a4\u30ba\u306e\u6a5f\u5668\u3082\u591a\u304f\u51fa\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u306e\u70b9\u306f\u3082\u306f\u3084\u300c\u30c7\u30e1\u30ea\u30c3\u30c8\u300d\u3067\u306f\u306a\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u305f\u3068\u3048\u3070\u3001\u4ee3\u8868\u7684\u306a\u30b3\u30f3\u30d1\u30af\u30c8\u86cd\u5149\u691c\u51fa\u5668\u3068\u3057\u3066<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fluorometers\/qubit.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 Qubit\u2122 4 Fluorometer<\/a>\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12349\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482-1024x682.png\" alt=\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\" width=\"760\" height=\"506\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482-1024x682.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482-300x200.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482-768x512.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482-96x65.png 96w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/5ba897d6d697425ab4b38f14e988b482.png 1280w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>Qubit\u2122 4 Fluorometer \u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u4ee5\u5916\u306b\u3082DNA\u3084RNA\u3092\u6e2c\u5b9a\u3067\u304d\u308b\u6a5f\u5668\u3067\u3059\u3002\u30b5\u30a4\u30ba\u306fiPad\u2122\uff08iPad Air\u2122\uff09\u3068\u540c\u3058\u304f\u3089\u3044\u3067\u3001\u91cd\u3055\u30821 kg\u672a\u6e80\u3002\u5c0f\u578b\u3067\u8efd\u91cf\u3067\u3059\u3002\u5b9a\u91cf\u3059\u308b\u3068\u304d\u306f\u3001\u5c02\u7528\u30ad\u30c3\u30c8\u3067\u4f5c\u6210\u3057\u305fWorking Reagent\u3092\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3084\u30b5\u30f3\u30d7\u30eb\u3068\u6df7\u305c\u3066\u6e2c\u5b9a\u3059\u308b\u3060\u3051\u3002Qubit\u2122 4 Fluorometer\u304c\u753b\u9762\u306b\u6fc3\u5ea6\u3092\u8868\u793a\u3057\u3066\u304f\u308c\u308b\u306e\u3067\u3001\u3069\u306a\u305f\u3067\u3082\u7c21\u5358\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5b9a\u91cf\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306e\u307b\u304b\u306b\u30828\u9023\u30c1\u30e5\u30fc\u30d6\u3067\u6e2c\u5b9a\u3067\u304d\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fluorometers\/qubit\/qubit-flex-fluorometer.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 Qubit\u2122 Flex Fluorometer<\/a>\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><b>Qubit Fluorometer\u7528\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u30ad\u30c3\u30c8\uff1a<\/b><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A50668?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 Qubit\u2122 Protein and Protein BR Assay Kits<\/a><br \/>\n\u30fb\u611f\u5ea6100 \u00b5g\/mL \uff5e 20 mg\/mL\uff08\u88fd\u54c1\u756a\u53f7A50668\uff09<br \/>\n\u30fb\u611f\u5ea612.5 \u00b5g\/mL \uff5e 5 mg\/mL\uff08\u88fd\u54c1\u756a\u53f7Q33211\uff09<\/p>\n<p>\u305d\u306e\u307b\u304b\u306e\u86cd\u5149\u3092\u7528\u3044\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3001\u754c\u9762\u6d3b\u6027\u5264\u3092\u4ecb\u3057\u3066\u86cd\u5149\u8272\u7d20\u304c\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u7d50\u5408\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/Q33210?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 Quant-iT\u2122 Protein Assay<\/a>\u3084<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/N6666?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">NanoOrange\u2122 Protein Quantification Assay<\/a>\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30a2\u30df\u30ce\u57fa\u306b\u7d50\u5408\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C6667?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 CBQCA Protein Quantification Assay<\/a>\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u6210\u5206\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u3044<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/R33200?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 EZQ\u2122 Protein Quantification Assay<\/a>\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u52b1\u8d77\u6ce2\u9577\u3084\u86cd\u5149\u6ce2\u9577\u3001\u86cd\u5149\u8272\u7d20\u306e\u6027\u8cea\u306a\u3069\u304c\u7570\u306a\u308a\u307e\u3059\u306e\u3067\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/protein-assays\/fluorescent-protein-assays.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u9078\u629e\u30ac\u30a4\u30c9<\/a>\u3092\u5229\u7528\u3057\u3066\u3001\u304a\u6301\u3061\u306e\u691c\u51fa\u5668\u3084\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u3063\u305f\u3082\u306e\u3092\u9078\u3073\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>\u7d50\u5c40\u3001\u3069\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u304c\u3088\u3044\u306e\u304b\uff1f<\/h2>\n<p>\u3055\u3066\u3001\u6570\u56de\u306b\u308f\u305f\u3063\u3066\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u9078\u629e\u80a2\u304c\u305f\u304f\u3055\u3093\u3042\u3063\u3066\u3001\u7d50\u5c40\u3069\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u304c\u826f\u3044\u306e\u304b\u8ff7\u3063\u3066\u3057\u307e\u3044\u307e\u3059\u3088\u306d\u3002\u3057\u304b\u3057\u3001\u300c\u3069\u306e\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u304c\u826f\u3044\u306e\u304b\u300d\u3068\u3044\u3046\u554f\u3044\u306b\u3001\u7b54\u3048\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306b\u300c\u4e07\u80fd\u306a\u65b9\u6cd5\u300d\u306f\u306a\u3044\u304b\u3089\u3067\u3059\u3002\u305d\u308c\u305e\u308c\u30e1\u30ea\u30c3\u30c8\u3068\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u304b\u3089\u3053\u305d\u30011951\u5e74\u306b\u958b\u767a\u3055\u308c\u305fLowry\u6cd5\u3092\u542b\u3081\u3001\u8907\u6570\u306e\u65b9\u6cd5\u304c\u4eca\u3067\u3082\u4f7f\u308f\u308c\u3066\u304a\u308a\u3001\u3055\u3089\u306b\u30e1\u30fc\u30ab\u30fc\u72ec\u81ea\u306e\u65b9\u6cd5\u306a\u3069\u65b0\u3057\u3044\u5b9a\u91cf\u6cd5\u3082\u958b\u767a\u3055\u308c\u7d9a\u3051\u3066\u3044\u307e\u3059\u3002\u4e07\u80fd\u306a\u65b9\u6cd5\u306f\u306a\u3044\u304b\u3089\u3053\u305d\u3001\u539f\u7406\u3084\u30e1\u30ea\u30c3\u30c8\u3068\u30c7\u30e1\u30ea\u30c3\u30c8\u3092\u898b\u6975\u3081\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u3084\u4e0b\u6d41\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u305f\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3092\u9078\u3076\u3053\u3068\u304c\u5927\u5207\u3067\u3059\u3002<\/p>\n<p>\u8868. \u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u307e\u3068\u3081\u3000\u203b\u30af\u30ea\u30c3\u30af\u3067\u62e1\u5927\u8868\u793a\u3067\u304d\u307e\u3059\u3002<br \/>\n<a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996-1024x540.png\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12389\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996-1024x540.png\" alt=\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\" width=\"760\" height=\"401\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996-1024x540.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996-300x158.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996-768x405.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/43df8b77ae08f65baa8ace315c8b6996.png 1124w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/a><\/p>\n<h2>\u300c\u4e07\u80fd\u306a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u300d\u306f\u306a\u3044\u3002<br \/>\n\u30b5\u30f3\u30d7\u30eb\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5408\u3063\u305f\u5b9a\u91cf\u6cd5\u3092\uff01<\/h2>\n<p>\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306b\u306f\u3001BCA\u6cd5\u3084Bradford\u6cd5\u306a\u3069\u3092\u306f\u3058\u3081\u3068\u3057\u305f\u767a\u8272\u6cd5\u3001\u7c21\u4fbf\u306aUV\u6cd5\u3001\u611f\u5ea6\u304c\u9ad8\u3044\u86cd\u5149\u6cd5\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u4e07\u80fd\u306a\u5b9a\u91cf\u6cd5\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3060\u304b\u3089\u3053\u305d\u3001\u5404\u5b9a\u91cf\u6cd5\u306e\u7279\u5fb4\u3092\u6349\u3048\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u3084\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u305f\u5b9a\u91cf\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3001\u8fc5\u901f\u3067\u7cbe\u5ea6\u9ad8\u3044\u5b9a\u91cf\u3092\u884c\u3046\u8fd1\u9053\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u30d6\u30ed\u30b0\u3092\u898b\u305f\u4eba\u306f\u3001\u3053\u3093\u306a\u30d6\u30ed\u30b0\u3082\u898b\u3066\u3044\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic4\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">BCA\u6cd5\u3001Bradford\u6cd5\u3001Lowry\u6cd5\u306a\u3069\u3001\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u539f\u7406\u307e\u3068\u3081\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c \u7b2c4\u56de<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic3\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u201c\u7dcf\u201c\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u7a2e\u985e\u3092\u307e\u3068\u3081\u3066\u307f\u305f\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u3042\u308c\u3053\u308c\u7b2c3\u56de<\/a><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><br \/>\n&nbsp;<\/p>\n<h2>\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u95a2\u9023\u3001\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089<\/h2>\n<table style=\"border-color: lightgray;border-collapse: collapse;padding: 20px\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"border-color: lightgray;padding: 20px\">\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic1\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c1\u56de\u3011\u754c\u9762\u6d3b\u6027\u5264\u3092\u7528\u3044\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic2\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c2\u56de\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u306b\u4f7f\u7528\u3059\u308b\u754c\u9762\u6d3b\u6027\u5264\u306e\u7279\u6027\u3068\u7a2e\u985e<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic3\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c3\u56de\u3011\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u7a2e\u985e\u3092\u307e\u3068\u3081\u3066\u307f\u305f<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic4\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c4\u56de\u3011BCA\u6cd5\u3001Bradford\u6cd5\u3001Lowry\u6cd5\u306a\u3069\u3001\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u539f\u7406\u307e\u3068\u3081<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic5\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c5\u56de\u3011\u900f\u6790\u3001\u30b2\u30eb\u308d\u904e\u3001\u9650\u5916\u308d\u904e\u306a\u3069\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u593e\u96d1\u6210\u5206\u306e\u9664\u53bb\u65b9\u6cd5\u307e\u3068\u3081<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic19\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c19\u56de\u3011\u8cea\u91cf\u5206\u6790\u8a08\u306e\u57fa\u672c\u306e\u300c\u304d\u300d<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic20\/?CID=bid_pca_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_protein_basic24_bid_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c20\u56de\u3011\u5b9a\u91cf\u30d7\u30ed\u30c6\u30aa\u30df\u30af\u30b9\u3068\u306f\uff1f<br \/>\n<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<br \/>\niPad and iPad Air are trademarks of Apple Inc.<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u524d\u56de\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3088\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u767a\u8272\u6cd5\uff08BCA\u6cd5\u3001Bradford\u6cd5\u3001 Lowry\u6cd5\u3001Pierce 660 nm\u6cd5\uff09\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002 \u3053\u308c\u3089\u767a\u8272\u6cd5\u4ee5\u5916\u306b\u3082\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3001U<\/p>\n","protected":false},"author":988,"featured_media":12335,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[],"division":[],"class_list":["post-12296","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u524d\u56de\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3088\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u767a\u8272\u6cd5\uff08BCA\u6cd5\u3001Bradford\u6cd5\u3001 Lowry\u6cd5\u3001Pierce 660 nm\u6cd5\uff09\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002 \u3053\u308c\u3089\u767a\u8272\u6cd5\u4ee5\u5916\u306b\u3082\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3001U\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-01T01:44:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-28T04:57:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f\",\"datePublished\":\"2022-08-01T01:44:43+00:00\",\"dateModified\":\"2025-05-28T04:57:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/\"},\"wordCount\":136,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1472782919.jpg\",\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/\",\"name\":\"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1472782919.jpg\",\"datePublished\":\"2022-08-01T01:44:43+00:00\",\"dateModified\":\"2025-05-28T04:57:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1472782919.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/07\\\/shutterstock_1472782919.jpg\",\"width\":1000,\"height\":667,\"caption\":\"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-basic24_bid_ts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/","og_locale":"ja_JP","og_type":"article","og_title":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f","og_description":"\u524d\u56de\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3088\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u767a\u8272\u6cd5\uff08BCA\u6cd5\u3001Bradford\u6cd5\u3001 Lowry\u6cd5\u3001Pierce 660 nm\u6cd5\uff09\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002 \u3053\u308c\u3089\u767a\u8272\u6cd5\u4ee5\u5916\u306b\u3082\u3001\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u3068\u3057\u3066\u3001U","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-08-01T01:44:43+00:00","article_modified_time":"2025-05-28T04:57:50+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f","datePublished":"2022-08-01T01:44:43+00:00","dateModified":"2025-05-28T04:57:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/"},"wordCount":136,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/","name":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","datePublished":"2022-08-01T01:44:43+00:00","dateModified":"2025-05-28T04:57:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","width":1000,"height":667,"caption":"\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic24_bid_ts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u201c\u7dcf\u201d\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u6cd5\u306e\u307e\u3068\u3081\u7d9a\u304d\uff5c\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01UV\u6cd5\u3084\u86cd\u5149\u6cd5\u3092\u4f7f\u3046\u306e\u306f\u3069\u3093\u306a\u3068\u304d\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg",760,507,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":12296,"position":0},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":12296,"position":1},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":12296,"position":2},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":12296,"position":3},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":12296,"position":4},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":12296,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/07\/shutterstock_1472782919.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12296"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12296\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12335"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12296"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12296"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}