{"id":12461,"date":"2022-08-24T17:24:42","date_gmt":"2022-08-24T08:24:42","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12461"},"modified":"2023-12-27T15:56:09","modified_gmt":"2023-12-27T06:56:09","slug":"basic_ngs_workshop_gsd_ts","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f"},"content":{"rendered":"<p>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u907a\u4f1d\u5b50\u3092\u7db2\u7f85\u7684\u304b\u3064\u591a\u69d8\u306a\u7528\u9014\uff08\u5909\u7570\u89e3\u6790\u3084\u767a\u73fe\u89e3\u6790\u306a\u3069\uff09\u3067\u89e3\u6790\u3067\u304d\u308b\u975e\u5e38\u306b\u5f37\u529b\u306a\u5206\u6790\u88c5\u7f6e\u3067\u3059\u3002\u4e00\u6614\u524d\u307e\u3067NGS\uff08Next Generation Sequencing\uff09\u306f\u6577\u5c45\u304c\u9ad8\u304f\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306b\u624b\u304c\u51fa\u305b\u308b\u88c5\u7f6e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u8fd1\u5e74\u306f\u5b9f\u9a13\u65b9\u6cd5\u304c\u5b9a\u7740\u3057\u3066\u304d\u305f\u3053\u3068\u3084\u65b0\u305f\u306a\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u958b\u767a\u306a\u3069\u306b\u3088\u308a\u3001\u4ee5\u524d\u3088\u308a\u6271\u3044\u3084\u3059\u3044\u5206\u6790\u6a5f\u5668\u306b\u306a\u3063\u3066\u304d\u305f\u3068\u3044\u3048\u307e\u3059\u3002<\/p>\n<p>\u4e00\u65b9\u3001\u5b9f\u9a13\u30b3\u30b9\u30c8\u306b\u3064\u3044\u3066\u306f\u4ee5\u524d\u3088\u308a\u304b\u306a\u308a\u5b89\u4fa1\u306b\u306a\u3063\u3066\u304d\u305f\u3068\u306f\u3044\u3048\u3001\u4ed6\u306e\u5b9f\u9a13\u7cfb\u3068\u6bd4\u8f03\u3059\u308b\u3068\u4f9d\u7136\u3068\u3057\u3066\u9ad8\u984d\u3067\u3001\u5b9f\u9a13\u306b\u5931\u6557\u3057\u3066\u3057\u307e\u3046\u3068\u5927\u304d\u306a\u640d\u5931\u3068\u306a\u308a\u307e\u3059\u3002\u3067\u304d\u308b\u3060\u3051\u591a\u304f\u306e\u30c7\u30fc\u30bf\u3092\u7c21\u5358\u306b\u5f97\u3088\u3046\u3068\u3057\u305f\u5834\u5408\u3001\u307e\u305a\u3069\u306e\u3088\u3046\u306a\u3053\u3068\u304c\u601d\u3044\u3064\u304f\u3067\u3057\u3087\u3046\u304b\u3002\u4eca\u56de\u306f\u3042\u3048\u3066\u30e6\u30fc\u30b6\u30fc\u30ac\u30a4\u30c9\u304b\u3089\u5916\u308c\u305f\u6761\u4ef6\u3067\u5b9f\u9a13\u3059\u308b\u3053\u3068\u3067\u3001\u3069\u306e\u69d8\u306a\u7d50\u679c\u3092\u62db\u304f\u306e\u304b\u691c\u8a3c\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u89e3\u6790\u7d50\u679c\u3092\u53c2\u8003\u306b\u3001\u5b9f\u969b\u306b\u5b9f\u9a13\u3057\u3066\u3044\u305f\u3060\u304f\u969b\u306e\u6ce8\u610f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u306a\u304a\u3001\u672c\u8a18\u4e8b\u306e\u3088\u3046\u306b\u63a8\u5968\u3092\u9038\u8131\u3057\u305f\u6761\u4ef6\u3067\u5b9f\u9a13\u3092\u884c\u3046\u3068\u7d50\u679c\u304c\u5f97\u3089\u308c\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u771f\u4f3c\u3055\u308c\u306a\u3044\u3088\u3046\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><b>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fbNGS\u89e3\u6790\u306b\u8208\u5473\u304c\u3042\u308b<br \/>\n\u30fbNGS\u306e\u5b9f\u9a13\u65b9\u6cd5\u306b\u3064\u3044\u3066\u77e5\u308a\u305f\u3044<br \/>\n\u30fb\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3067\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u306b\u60a9\u3093\u3067\u3044\u308b<\/p>\n<h2>NGS\u89e3\u6790\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u4eca\u56de\u306e\u691c\u8a3c\u5185\u5bb9<\/h2>\n<p>Ion Torrent\u2122\u30b7\u30b9\u30c6\u30e0\u3092\u306f\u3058\u3081\u3068\u3059\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u5b9f\u9a13\u306f\u3001\u4e00\u822c\u7684\u306b\u306f\u2460\u6838\u9178\u7cbe\u88fd\u3001\u2461\u76ee\u7684\u306eDNA\u3042\u308b\u3044\u306fRNA\u3092\u89e3\u6790\u53ef\u80fd\u306a\u72b6\u614b\u306b\u52a0\u5de5\u3059\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u3001\u2462\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u524d\u51e6\u7406\u306b\u3042\u305f\u308b\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3001\u2463\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u3001\u3068\u3044\u30464\u3064\u306e\u30b9\u30c6\u30c3\u30d7\u306b\u5206\u304b\u308c\u3066\u3044\u307e\u3059\uff08\u56f31\uff09\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12512\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-1024x331.jpg\" alt=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"760\" height=\"246\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-1024x331.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-300x97.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-768x248.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-1536x497.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/795316b92fc766b0181f6fef074f03fa-2048x662.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u306b\u3064\u3044\u3066\u306f\u5404\u793e\u306e\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3054\u3068\u306b\u624b\u6cd5\u304c\u7570\u306a\u308a\u3001Ion Torrent\u3067\u306f\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u3068\u3044\u3046\u65b9\u6cd5\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306f\u30aa\u30a4\u30eb\u4e2d\u306b\u5b58\u5728\u3059\u308b\u5404\u6c34\u6ef4\u5185\u306b1\u5206\u5b50\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u30681\u500b\u306e\u30a2\u30c0\u30d7\u30bf\u30fc\u3068\u76f8\u88dc\u7684\u306aDNA\u304c\u7d50\u5408\u3057\u305f\u30d3\u30fc\u30ba\uff08ISP\uff1aIon Sphere Particle\uff09\u304c\u542b\u307e\u308c\u308b\u72b6\u614b\u3067PCR\u53cd\u5fdc\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001ISP\u4e0a\u306b\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3092\u5897\u5e45\u3057\u307e\u3059\uff08\u56f32\uff09\u3002\u3053\u306e\u5de5\u7a0b\u306fIon Torrent\u88fd\u54c1\u3067\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4474779?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion OneTouch\u2122 2 System<\/a>\u3084<a href=\"http:\/\/thermofisher.com\/order\/catalog\/product\/4484177?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion Chef\u2122 Instrument<\/a>\u3067\u884c\u308f\u308c\u307e\u3059\u3002\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306f\u30aa\u30a4\u30eb\u4e2d\u306b\u5b58\u5728\u3059\u308b\u5404\u6c34\u6ef4\u5185\u306b1\u5206\u5b50\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u30681\u500b\u306eISP\uff08Ion Sphere Particle\uff09\u304c\u542b\u307e\u308c\u308b\u72b6\u614b\u3067PCR\u53cd\u5fdc\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001ISP\u4e0a\u306b\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3092\u5897\u5e45\u3057\u307e\u3059\uff08\u56f32\uff09\u3002\u3053\u306e\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306b\u3088\u3063\u3066\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3092\u5897\u5e45\u3055\u305b\u305fISP\u3092\u6700\u7d42\u7684\u306b\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u306b\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u3057\u3001\u5404ISP\u306e\u5897\u5e45\u3057\u305fDNA\u914d\u5217\u3092\u89e3\u6790\u3059\u308b\u3053\u3068\u3067\u30b5\u30f3\u30d7\u30eb\u306e\u914d\u5217\u60c5\u5831\u3092\u53d6\u5f97\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12513\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-1024x474.jpg\" alt=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"760\" height=\"352\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-1024x474.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-300x139.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-768x355.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-1536x711.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/2b530e80c7d0de90885e285c5d798063-2048x948.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306b\u3088\u308b\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3092\u884c\u3046\u969b\u3001PCR\u306e\u539f\u7406\u3092\u8003\u3048\u308b\u3068\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u304c\u591a\u3044\u65b9\u304cISP\u306e\u53ce\u91cf\u304c\u5897\u3048\u308b\u3088\u3046\u306b\u601d\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u3067\u306f\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3054\u3068\u306b\u76ee\u5b89\u3068\u306a\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u304c\u6c7a\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3082\u3057\u63a8\u5968\u3092\u8d85\u3048\u308b\u6fc3\u5ea6\u3067\u5b9f\u9a13\u3092\u884c\u3063\u305f\u5834\u5408\u3001\u3069\u306e\u3088\u3046\u306a\u7d50\u679c\u304c\u751f\u3058\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u305d\u3053\u3067\u3001\u4eca\u56de\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3067\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u3042\u3048\u3066\u904e\u5270\u306b\u3059\u308b\u3053\u3068\u3067\u89e3\u6790\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u306e\u304b\u691c\u8a3c\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n<p>\uff1c\u5408\u308f\u305b\u3066\u8aad\u307f\u305f\u3044\uff1a<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_gsd_mkt_1?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\/\" target=\"_blank\" rel=\"noopener\">\u30b2\u30ce\u30e0\u89e3\u6790\u65b0\u6642\u4ee3\uff01 \u4eca\u3060\u304b\u3089\u3053\u305d\u805e\u304d\u305f\u3044\uff01Ion Torrent\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u539f\u7406<\/a>\uff1e<\/p>\n<h2>\u6750\u6599\u3068\u65b9\u6cd5 -Ion GeneStudio S5\u306b\u3088\u308b\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790-<\/h2>\n<p><b>\u4f7f\u7528\u3057\u305f\u6a5f\u5668<\/b><br \/>\n\u30fb\u3000<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A27214?SID=srch-srp-A27214?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion S5\u2122 XL System<\/a> (A27214)<br \/>\n\u30fb\u3000<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4484177?SID=srch-hj-4484177?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion Chef\u2122 Instrument<\/a> (4484177)<\/p>\n<p><b>\u4f7f\u7528\u3057\u305f\u8a66\u85ac<\/b><br \/>\n\u30fb\u3000<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A30011?SID=srch-srp-A30011?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion 540\u2122 Kit-Chef<\/a> (A30011)<br \/>\n\u30fb\u3000<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A27765?SID=srch-srp-A27765?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion 540\u2122 Chip Kit<\/a> (A27765)<br \/>\n\u30fb\u3000<a href=\"http:\/\/thermofisher.com\/order\/catalog\/product\/A30729?SID=srch-hj-A30729?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">Ion S5\u2122 Controls Kit Plus<\/a> (A30729) (Human CEPH Control 200 Library\u3092\u4f7f\u7528)<\/p>\n<p><b>\u624b\u9806<\/b><br \/>\nIon Chef\u2122 Instrument\u3067\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3001Ion S5\u2122 XL System\u3067\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u306f1\u56de\u306e\u89e3\u6790\u30676,000\uff5e8,000\u4e07\u30ea\u30fc\u30c9\u53d6\u5f97\u3067\u304d\u308bIon 540\u2122 Chip\u3001\u89e3\u6790\u30b5\u30f3\u30d7\u30eb\u306fIon S5 Controls Kit Plus\u306e\u69cb\u6210\u54c1\u3067\u3042\u308bHuman CEPH Control 200 Library\u3092\u7528\u3044\u307e\u3057\u305f\u3002\u3053\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u306f\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u78ba\u8a8d\u3059\u308b\u969b\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u3057\u3066\u7528\u3044\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u6642\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u306f\u4ee5\u4e0b\u306e\u6761\u4ef6\u3067\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u300050 pM\uff08\u63a8\u5968\u6fc3\u5ea6\uff09<br \/>\n\u30fb\u3000200 pM\uff08\u904e\u5270\u6fc3\u5ea6\uff09<br \/>\n\u30fb\u3000400 pM\uff08\u904e\u5270\u6fc3\u5ea6\uff09<\/p>\n<p>\u305d\u306e\u4ed6\u306e\u6761\u4ef6\u306b\u3064\u3044\u3066\u306fIon GeneStudio\u2122 S5\u3001Ion Chef\u2122\u304a\u3088\u3073Ion 540\u2122 Kit \u2013 Chef\u306e\u30e6\u30fc\u30b6\u30fc\u30ac\u30a4\u30c9\u306b\u5f93\u3044\u307e\u3057\u305f\u3002<\/p>\n<h2>\u7d50\u679c\u3068\u8003\u5bdf -\u306a\u305c\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u5897\u3084\u3057\u3066\u3082\u30ea\u30fc\u30c9\u6570\u304c\u5897\u3048\u306a\u3044\u306e\u304b-<\/h2>\n<p>\u65e9\u901f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3092\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u307e\u305a\u3001\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u306e\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\uff08\u56f33\uff09\u306b\u7740\u76ee\u3059\u308b\u3068\u3001\u3044\u305a\u308c\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3067\u3082\u5168\u4f53\u304c\u8d64\u304f\u8868\u793a\u3055\u308c\u3066\u3044\u308b\u306e\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3053\u308c\u306fISP\u304c\u534a\u5c0e\u4f53\u30c1\u30c3\u30d7\u5168\u4f53\u306b\u304f\u307e\u306a\u304f\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u306e\u7d50\u679c\u3092\u898b\u308b\u9650\u308a\u306f\u3044\u305a\u308c\u306e\u6761\u4ef6\u3067\u3082\u554f\u984c\u306a\u304f\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u3067\u304d\u3066\u3044\u308b\u3088\u3046\u306b\u898b\u3048\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12514\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-1024x570.jpg\" alt=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"760\" height=\"423\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-1024x570.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-300x167.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-768x428.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-1536x856.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-2048x1141.jpg 2048w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/c8856789ec11ab8b1013037cef6929f9-450x250.jpg 450w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u6b21\u306b\u305d\u308c\u305e\u308c\u306e\u89e3\u6790\u7d50\u679c\u306b\u3064\u3044\u3066\u30e9\u30f3\u30ec\u30dd\u30fc\u30c8\u306e\u8a73\u7d30\u3092\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\uff08\u56f34\uff09\u3002\u63a8\u5968\u6fc3\u5ea6\u3067\u3042\u308b50 pM\u3067\u306f\u89e3\u6790\u53ef\u80fd\u306a\u30ea\u30fc\u30c9\u6570\u3092\u793a\u3059Total Reads\u304c\u7d047,700\u4e07\u30ea\u30fc\u30c9\u3068\u306a\u3063\u3066\u304a\u308a\u30b9\u30da\u30c3\u30af\u3092\u5341\u5206\u306b\u6e80\u305f\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3067200 pM\u3067\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3092\u884c\u3063\u305f\u7d50\u679c\u306b\u6ce8\u76ee\u3059\u308b\u3068\u3001\u53d6\u5f97\u30ea\u30fc\u30c9\u6570\u306f6,400\u4e07\u30ea\u30fc\u30c9\u3067\u3059\u306e\u3067Ion 540\u2122 Chip\u306e\u30b9\u30da\u30c3\u30af\u306f\u6e80\u305f\u3057\u3066\u3044\u307e\u3059\u304c\u300150 pM\u306e\u89e3\u6790\u7d50\u679c\u3068\u6bd4\u3079\u30661,000 \u4e07\u30ea\u30fc\u30c9\u4ee5\u4e0a\u3082Total Reads\u304c\u6e1b\u5c11\u3057\u3066\u3057\u307e\u3044\u307e\u3057\u305f\u3002\u5404\u6761\u4ef6\u3067\u306e\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u3068\u3001200 pM\u3067\u306fISP Summary\u306eClonal\u5272\u5408\u304c68%\u304b\u308957%\u306b\u6e1b\u5c11\u3057\u3066\u3044\u308b\u306e\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u53cd\u5bfe\u306bPolyclonal\u306e\u5272\u5408\u306f32%\u304b\u308943%\u306b\u5897\u52a0\u3057\u3066\u3044\u307e\u3059\u3002400 pM\u3067\u306fTotal Reads\u304c\u7d044,800\u4e07\u30ea\u30fc\u30c9\u3057\u304b\u53d6\u5f97\u3067\u304d\u3066\u304a\u3089\u305a\u3001Ion 540\u2122 Chip\u3067\u671f\u5f85\u3055\u308c\u308b\u30b9\u30da\u30c3\u30af\u3092\u6e80\u305f\u3057\u3066\u3044\u307e\u305b\u3093\u3067\u3057\u305f\u3002Clonal\u3068Polyclonal\u306e\u5272\u5408\u306b\u3064\u3044\u3066\u3082\u3001\u305d\u308c\u305e\u308c49%\u306851%\u3068\u306a\u3063\u3066\u304a\u308a\u3001200 pM\u3088\u308a\u3082\u3088\u308aClonal\u306e\u5272\u5408\u304c\u6e1b\u5c11\u3057\u3001Polyclonal\u304c\u5897\u52a0\u3057\u3066\u3044\u308b\u306e\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12515\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1024x437.jpg\" alt=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"760\" height=\"324\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1024x437.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-300x128.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-768x328.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1536x656.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/3a4f695a458cb0ac0aceaa2eb13ac2dd-2048x875.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u3053\u3053\u3067\u51fa\u3066\u304f\u308bClonal\u3068\u3044\u3046\u306e\u306f1\u7a2e\u985e\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u7531\u6765\u306eDNA\u914d\u5217\u304c\u5897\u5e45\u3057\u305fISP\u306e\u5272\u5408\u3092\u793a\u3057\u307e\u3059\u3002\u53cd\u5bfe\u306bPolyclonal\u306f\u8907\u6570\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u306eDNA\u914d\u5217\u304c\u5897\u5e45\u3057\u3066\u3044\u308bISP\u306e\u5272\u5408\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002\u3059\u306a\u308f\u3061\u4eca\u56de\u306e\u89e3\u6790\u7d50\u679c\u3067\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u6642\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u5897\u3084\u3059\u3053\u3068\u3067\u8907\u6570\u306eDNA\u914d\u5217\u304c\u5897\u5e45\u3057\u305fISP\uff08Polyclonal\uff09\u304c\u5897\u52a0\u3057\u3001\u305d\u308c\u304c\u539f\u56e0\u3068\u306a\u3063\u3066\u53d6\u5f97\u30ea\u30fc\u30c9\u6570\u304c\u6e1b\u5c11\u3057\u305f\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u306a\u305c\u3053\u306e\u69d8\u306a\u73fe\u8c61\u304c\u8d77\u3053\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<br \/>\n\u5b9f\u306f\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306e\u539f\u7406\u3068\u5bc6\u63a5\u306a\u95a2\u4fc2\u304c\u3042\u308a\u307e\u3059\u3002\u5192\u982d\u3067\u7d39\u4ecb\u3057\u305f\u3088\u3046\u306b\u30a8\u30de\u30eb\u30b8\u30e7\u30f3PCR\u306f\u30aa\u30a4\u30eb\u4e2d\u306e\u6c34\u6ef4\u5185\u306b1\u5206\u5b50\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u30681\u500b\u306eISP\u3092\u542b\u3080\u72b6\u614b\u3067PCR\u53cd\u5fdc\u3092\u884c\u3044\u3001ISP\u4e0a\u306bDNA\u3092\u5897\u5e45\u3059\u308b\u624b\u6cd5\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u306e\u6642\u306b2\u672c\u4ee5\u4e0a\u306eDNA\u65ad\u7247\u304c1\u3064\u306e\u6c34\u6ef4\u5185\u306b\u5165\u3063\u3066\u3057\u307e\u3046\u3068\u8907\u6570\u7a2e\u985e\u306e\u5869\u57fa\u914d\u5217\u304c\u540c\u4e00\u306eISP\u4e0a\u306b\u5897\u5e45\uff08Polyclonal\u5897\u5e45\uff09\u3057\u307e\u3059\uff08\u56f35\uff09\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-12516\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-1024x936.jpg\" alt=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\" width=\"760\" height=\"695\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-1024x936.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-300x274.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-768x702.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-1536x1404.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/f96d9b4281f6d16b3c7589aed5a17be5-2048x1872.jpg 2048w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\n<p>\u3064\u307e\u308a\u3001\u4eca\u56de\u306e\u691c\u8a3c\u5b9f\u9a13\u306b\u304a\u3044\u3066\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u305f\u6761\u4ef6\u3067\u306f\u6c34\u6ef4\u5185\u306b2\u672c\u4ee5\u4e0a\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u304c\u6df7\u5728\u3059\u308b\u78ba\u7387\u304c\u9ad8\u307e\u308a\u3001Polyclonal\u306e\u5272\u5408\u304c\u5897\u52a0\u3057\u3066\u3057\u307e\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002Polyclonal\u3068\u306a\u3063\u305fISP\u304b\u3089\u306f\u8907\u6570\u306eDNA\u914d\u5217\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u3066\u3057\u307e\u3046\u305f\u3081\u6b63\u5e38\u306a\u89e3\u6790\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u3053\u306e\u3088\u3046\u306a\u30ea\u30fc\u30c9\u306f\u89e3\u6790\u6642\u306b\u30d5\u30a3\u30eb\u30bf\u30fc\u306b\u3088\u3063\u3066\u9664\u5916\u3055\u308c\u308b\u305f\u3081\u3001\u53d6\u5f97\u30ea\u30fc\u30c9\u6570\u3092\u5897\u3084\u305d\u3046\u3068\u3057\u3066\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u3082\u3001\u6b8b\u5ff5\u306a\u304c\u3089\u7dcf\u30ea\u30fc\u30c9\u6570\u306f\u5897\u3048\u308b\u3069\u3053\u308d\u304b\u6e1b\u5c11\u3057\u3066\u3057\u307e\u3046\u306e\u3067\u3059\u3002<\/p>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n<p>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3067\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u306f\u5358\u306b\u591a\u304f\u3059\u308c\u3070\u826f\u3044\u3068\u3044\u3046\u8a33\u3067\u306f\u306a\u304f\u6700\u9069\u306a\u6fc3\u5ea6\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u3088\u3063\u3066\u6700\u3082\u52b9\u7387\u3088\u304f\u89e3\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u30e6\u30fc\u30b6\u30fc\u30ac\u30a4\u30c9\u306b\u57fa\u3065\u3044\u305f\u9069\u5207\u306a\u6761\u4ef6\u3067\u5b9f\u9a13\u3092\u884c\u3046\u3053\u3068\u304c\u975e\u5e38\u306b\u91cd\u8981\u306b\u306a\u3063\u3066\u304d\u307e\u3059\u3002<\/p>\n<p>\u5b9f\u969b\u306e\u5b9f\u9a13\u3067\u306f\u3042\u3048\u3066\u63a8\u5968\u6fc3\u5ea6\u3092\u9038\u8131\u3057\u3066\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3092\u884c\u3046\u3053\u3068\u306f\u5c11\u306a\u3044\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u4f5c\u88fd\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u306e\u5b9a\u91cf\u3092\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u524d\u306b\u6b63\u78ba\u306b\u884c\u3048\u3066\u3044\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u4eca\u56de\u306e\u3088\u3046\u306a\u904e\u5270\u91cf\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3092\u6295\u5165\u3057\u305f\u5b9f\u9a13\u6761\u4ef6\u304c\u518d\u73fe\u3055\u308c\u3066\u3057\u307e\u3046\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u5f53\u793e\u3067\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4468802?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">IonTaqMan\u2122 Library quantification kit<\/a>\u3092\u4f7f\u7528\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u5b9a\u91cf\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u88fd\u54c1\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u5024\u3092\u3082\u3068\u306b\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u3067\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u306e\u6295\u5165\u91cf\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08Ion Xpress\u2122 Barcode Adapters 1-16 Kit (4471250\uff09\u304a\u3088\u3073IonCode\u2122 Barcode Adapters 1-384 Kit (A29751)\u306e\u30a2\u30c0\u30d7\u30bf\u30fc\u3092\u4f7f\u7528\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3067\u4f7f\u7528\u53ef\u80fd\u3001Ion Xpress\u2122 RNA-Seq Barcode (4475485) \u306f\u975e\u5bfe\u5fdc\u3067\u3059\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044) \u3002<\/p>\n<p>\u307e\u305f\u4eca\u56de\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u8abf\u88fd\u306b\u3064\u3044\u3066\u306e\u3054\u7d39\u4ecb\u3060\u3051\u3067\u3057\u305f\u304c\u3001\u5b9f\u306fIon Torrent\u2122\u306e\u89e3\u6790\u306b\u306f\u5b9f\u9a13\u3092\u5b89\u5b9a\u7684\u306b\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306e\u30b3\u30c4\u304c\u4ed6\u306b\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u5f53\u793e\u3067\u306f\u5b9f\u9a13\u306e\u624b\u6280\u3092\u8a73\u7d30\u306b\u304a\u4f1d\u3048\u3059\u308b\u6a5f\u4f1a\u3068\u3057\u3066\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html#t8?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u4e2d\u3067\u306f\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u5404\u5de5\u7a0b\u3067\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u304fIon Torrent\u3092\u7528\u3044\u305f\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3042\u308b\u3044\u306f\u666e\u6bb5Ion Torrent\u2122\u3092\u7d99\u7d9a\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u3051\u308c\u3069\u3082\u6539\u3081\u3066\u624b\u6280\u3092\u78ba\u8a8d\u3057\u305f\u3044\u65b9\u306a\u3069\u3001\u3054\u8208\u5473\u3042\u308b\u65b9\u306f\u304a\u6c17\u8efd\u306b<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/jp-contact.html?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8<\/a>\u307e\u3067\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>&nbsp;<\/p>\n<h2>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9 \u30c7\u30fc\u30bf\u89e3\u6790\u30aa\u30f3\u30e9\u30a4\u30f3\u500b\u5225\u76f8\u8ac7<\/h2>\n<p>IonTorrent\u30e6\u30fc\u30b6\u3067\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u95a2\u3059\u308b\u5177\u4f53\u7684\u306a\u8ab2\u984c\u3092\u304a\u6301\u3061\u306e\u65b9\u306b\u306f\u3001\u7121\u6599\u306e\u500b\u5225\u76f8\u8ac7\u306e\u6642\u9593\u3092\u958b\u8a2d\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/ngs-data-analysis-online-consultation.html?cid=csd_ngs_sbu_r04_jp_cp1444_pjt7240_csd00000_0so_blg_op_awa_og_s00_basic_ngs_workshop_gsd_ts_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u907a\u4f1d\u5b50\u3092\u7db2\u7f85\u7684\u304b\u3064\u591a\u69d8\u306a\u7528\u9014\uff08\u5909\u7570\u89e3\u6790\u3084\u767a\u73fe\u89e3\u6790\u306a\u3069\uff09\u3067\u89e3\u6790\u3067\u304d\u308b\u975e\u5e38\u306b\u5f37\u529b\u306a\u5206\u6790\u88c5\u7f6e\u3067\u3059\u3002\u4e00\u6614\u524d\u307e\u3067NGS\uff08Next Generation Sequencing\uff09\u306f\u6577\u5c45\u304c\u9ad8\u304f\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306b\u624b\u304c\u51fa\u305b\u308b\u88c5<\/p>\n","protected":false},"author":975,"featured_media":13008,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[28],"division":[],"class_list":{"0":"post-12461","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-experiment","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u907a\u4f1d\u5b50\u3092\u7db2\u7f85\u7684\u304b\u3064\u591a\u69d8\u306a\u7528\u9014\uff08\u5909\u7570\u89e3\u6790\u3084\u767a\u73fe\u89e3\u6790\u306a\u3069\uff09\u3067\u89e3\u6790\u3067\u304d\u308b\u975e\u5e38\u306b\u5f37\u529b\u306a\u5206\u6790\u88c5\u7f6e\u3067\u3059\u3002\u4e00\u6614\u524d\u307e\u3067NGS\uff08Next Generation Sequencing\uff09\u306f\u6577\u5c45\u304c\u9ad8\u304f\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306b\u624b\u304c\u51fa\u305b\u308b\u88c5\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-24T08:24:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-27T06:56:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"562\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"13\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f\",\"datePublished\":\"2022-08-24T08:24:42+00:00\",\"dateModified\":\"2023-12-27T06:56:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/\"},\"wordCount\":183,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/08\\\/shutterstock_1669326868.jpg\",\"keywords\":[\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/08\\\/shutterstock_1669326868.jpg\",\"datePublished\":\"2022-08-24T08:24:42+00:00\",\"dateModified\":\"2023-12-27T06:56:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/08\\\/shutterstock_1669326868.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/08\\\/shutterstock_1669326868.jpg\",\"width\":1000,\"height\":562},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic_ngs_workshop_gsd_ts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f","og_description":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306f\u907a\u4f1d\u5b50\u3092\u7db2\u7f85\u7684\u304b\u3064\u591a\u69d8\u306a\u7528\u9014\uff08\u5909\u7570\u89e3\u6790\u3084\u767a\u73fe\u89e3\u6790\u306a\u3069\uff09\u3067\u89e3\u6790\u3067\u304d\u308b\u975e\u5e38\u306b\u5f37\u529b\u306a\u5206\u6790\u88c5\u7f6e\u3067\u3059\u3002\u4e00\u6614\u524d\u307e\u3067NGS\uff08Next Generation Sequencing\uff09\u306f\u6577\u5c45\u304c\u9ad8\u304f\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306b\u624b\u304c\u51fa\u305b\u308b\u88c5","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-08-24T08:24:42+00:00","article_modified_time":"2023-12-27T06:56:09+00:00","og_image":[{"width":1000,"height":562,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"13\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f","datePublished":"2022-08-24T08:24:42+00:00","dateModified":"2023-12-27T06:56:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/"},"wordCount":183,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","keywords":["\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","datePublished":"2022-08-24T08:24:42+00:00","dateModified":"2023-12-27T06:56:09+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","width":1000,"height":562},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic_ngs_workshop_gsd_ts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u6295\u5165\u91cf\u3092\u904e\u5270\u306b\u3057\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg",760,427,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":12461,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":12461,"position":1},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":12461,"position":2},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":12461,"position":3},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":12461,"position":4},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":12461,"position":5},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/08\/shutterstock_1669326868.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12461"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12461\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13008"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12461"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}