{"id":12549,"date":"2022-09-06T09:26:57","date_gmt":"2022-09-06T00:26:57","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12549"},"modified":"2024-12-25T16:17:41","modified_gmt":"2024-12-25T07:17:41","slug":"cell_culture_history_1_bid_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/","title":{"rendered":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09"},"content":{"rendered":"<p>\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u7528\u3044\u305f\u5b9f\u9a13\u3067\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3068\u5e73\u8861\u5869\u985e\u6eb6\u6db2\uff08\u30d0\u30c3\u30d5\u30a1\u30fc\uff09\u306b\u52a0\u3048\u3066\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u304c\u5fc5\u8981\u3067\u3059\u30022022\u5e74\u306b60\u5468\u5e74\u3092\u8fce\u3048\u305fGibco\u2122\u30d6\u30e9\u30f3\u30c9\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3084\u8840\u6e05\u3001\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3001\u5404\u7a2e\u30d0\u30c3\u30d5\u30a1\u30fc\u306a\u3069\u3068\u3068\u3082\u306b\u3001\u7d30\u80de\u306e\u6027\u8cea\u3084\u5b9f\u9a13\u306e\u76ee\u7684\u306b\u5408\u308f\u305b\u3066\u6570\u3005\u306e\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002Gibco60\u5468\u5e74\u306e\u7279\u96c6Web\u30b5\u30a4\u30c8\u306b\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u7279\u96c6\u8a18\u4e8b\u3084\u7d30\u80de\u5b9f\u9a13\u306b\u5f79\u7acb\u3064\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u306e\u30ea\u30bd\u30fc\u30b9\u304c\u96c6\u3081\u3089\u308c\u3066\u3044\u308b\u306e\u3067\u305c\u3072\u304a\u7acb\u3061\u5bc4\u308a\u304f\u3060\u3055\u3044\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/promotions\/2022\/gibco-60th.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Gibco 60\u5468\u5e74 | Thermo Fisher Scientific &#8211; JP<\/a>\uff09\u3002\u307e\u305f\u3001\u57fa\u790e\u57f9\u5730\u306e\u7d44\u6210\u306b\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3001\u95a2\u9023\u8a18\u4e8b\u306e\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff08<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment-2-bid-ts\/?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u790e\u57f9\u5730\u306e\u4e16\u754c<\/a>\uff09\u3002<\/p>\n<p>\u6570\u3042\u308b\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u306e\u306a\u304b\u3067\u3001\u6700\u3082\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u308b\u306e\u304cTrypsin-EDTA\u6eb6\u6db2\u3067\u3059\u3002Trypsin-EDTA\u304c\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u4f7f\u308f\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u305f\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u308b\u3068\u3001100\u5e74\u4ee5\u4e0a\u524d\u306b\u66f8\u304b\u308c\u305f\u8ad6\u6587\u306b\u305f\u3069\u308a\u7740\u304d\u307e\u3059\u3002\u305d\u306e\u8ad6\u6587\u3067\u306f\u3001\u7d30\u80de\u306e\u584a\u3067\u3042\u308b\u7d44\u7e54\u3092Trypsin\uff08EDTA\u306f\u542b\u307e\u306a\u3044\uff09\u3067\u51e6\u7406\u3057\u3066\u5f97\u3089\u308c\u305f\u7d30\u80de\u3092\u57f9\u990a\u3057\u3001\u3055\u3089\u306bTrypsin\u3067\u89e3\u96e2\u3057\u305f\u7d30\u80de\u3092\u7d99\u4ee3\u57f9\u990a\u3057\u305f\u3053\u3068\u304c\u8a18\u8ff0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7d30\u80de\u57f9\u990a\u3078\u306eTrypsin\u306e\u5fdc\u7528\u306f\u3001\u73fe\u5728\u307e\u3067\u53d7\u3051\u7d99\u304c\u308c\u3066\u3044\u308b\u63a5\u7740\u7d30\u80de\u306e\u57f9\u990a\u306e\u59cb\u307e\u308a\u3068\u8a00\u3063\u3066\u3082\u904e\u8a00\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u4eca\u56de\u306f\u8a18\u4e8b\u30922\u56de\u306b\u5206\u3051\u3066\u3001Trypsin\u3084EDTA\u304c\u7d30\u80de\u57f9\u990a\u306e\u4e16\u754c\u306b\u767b\u5834\u3057\u305f\u8ad6\u6587\u3092\u63a2\u7d22\u3057\u3001Trypsin-EDTA\u306b\u3088\u308b\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u6cd5\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u308a\u307e\u3059\u3002\u524d\u7de8\u3067\u306f\u3001Trypsin-EDTA\u3092\u542b\u3081\u305f\u3055\u307e\u3056\u307e\u306a\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3092\u78ba\u8a8d\u3057\u305f\u5f8c\u3001Trypsin\u521d\u767b\u5834\u306e\u8ad6\u6587\u3092\u6271\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_2_bid_ts_2\/?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f8c\u7de8<\/a>\u3067\u306f\u3001EDTA\u521d\u767b\u5834\u304a\u3088\u3073Trypsin\u3068EDTA\u306e\u6df7\u5408\u6db2\u304c\u57f9\u990a\u7d30\u80de\u306b\u521d\u3081\u3066\u4f7f\u308f\u308c\u305f\u8ad6\u6587\u3092\u6271\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001Trypsin\u3084EDTA\u3068\u95a2\u4fc2\u304c\u6df1\u3044\u7d30\u80de\u63a5\u7740\u5206\u5b50\u3067\u3042\u308b\u30ab\u30c9\u30d8\u30ea\u30f3\u3092\u767a\u898b\u3057\u305f\u7af9\u5e02\u96c5\u654f\u535a\u58eb\u3089\u306e\u8ad6\u6587\u306b\u3064\u3044\u3066\u3082\u89e6\u308c\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><b>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fb\u7d30\u80de\u57f9\u990a\u3092\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u65b9<br \/>\n\u30fbTrypsin-EDTA\u306b\u3064\u3044\u3066\u77e5\u308a\u305f\u3044\u65b9<br \/>\n\u30fb\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306b\u8208\u5473\u306e\u3042\u308b\u65b9<\/p>\n<h2>Trypsin-EDTA\u3068\u306f<\/h2>\n<p>\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u306f\u3001\u4f7f\u7528\u76ee\u7684\u5225\u306b\u3059\u308b\u3068\u5927\u304d\u304f3\u7a2e\u985e\u306b\u5206\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br \/>\n(1) \u4e3b\u3068\u3057\u3066\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3059\u308b\u9175\u7d20\u7cfb\u8a66\u85ac<br \/>\n(2) \u4e3b\u3068\u3057\u3066\u7d44\u7e54\u304b\u3089\u306e\u7d30\u80de\u306e\u5358\u96e2\u306b\u4f7f\u7528\u3059\u308b\u9175\u7d20\u7cfb\u8a66\u85ac<br \/>\n(3) \u975e\u9175\u7d20\u7684\u306b\u7d30\u80de\u3092\u5358\u96e2\u3059\u308b\u30ad\u30ec\u30fc\u30c8\u542b\u6709\u5e73\u8861\u5869\u985e\u6eb6\u6db2<\/p>\n<p>\u672c\u8a18\u4e8b\u3067\u306f\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u3092\u884c\u3046\u591a\u304f\u306e\u7814\u7a76\u8005\u306b\u3068\u3063\u3066\u306a\u3058\u307f\u6df1\u3044(1)\u306e\u4e2d\u3067\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u8a00\u3048\u308bTrypsin-EDTA\u3092\u6271\u3044\u307e\u3059\u3002\u305d\u306e\u4ed6\u306e\u8a66\u85ac\u306b\u3064\u3044\u3066\u306f\u3001\u672c\u8a18\u4e8b\u306e\u6700\u5f8c\u3067\u3054\u7d39\u4ecb\u3059\u308b\u306e\u3067\u3001\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Trypsin-EDTA\u306f\u3001\u305d\u306e\u540d\u306e\u901a\u308aTrypsin\u3068EDTA\uff08ethylenediaminetetraacetic acid\uff1a\u30a8\u30c1\u30ec\u30f3\u30b8\u30a2\u30df\u30f3\u56db\u9162\u9178\uff09\u306e\u6df7\u5408\u7269\u3067\u3042\u308a\u3001PBS\u306a\u3069\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6eb6\u304b\u3057\u305f\u72b6\u614b\u3067\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002Trypsin\u306f\u5c0f\u8178\u306b\u5206\u6ccc\u3055\u308c\u3066\u6d88\u5316\u5438\u53ce\u306b\u95a2\u308f\u308b\u81b5\u81d3\u7531\u6765\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u3002\u5f53\u793e\u304c\u8ca9\u58f2\u3057\u3066\u3044\u308b\u30c8\u30ea\u30d7\u30b7\u30f3\u306f\u4e3b\u306b\u30d6\u30bf\u306e\u81b5\u81d3\u304b\u3089\u62bd\u51fa\u3055\u308c\u305f\u3082\u306e\u3067\u3059\u3002Trypsin\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30a2\u30eb\u30ae\u30cb\u30f3\u3084\u30ea\u30b7\u30f3\u306e\u30ab\u30eb\u30dc\u30cb\u30eb\u5074\u306e\u30da\u30d7\u30c1\u30c9\u7d50\u5408\u3092\u9078\u629e\u7684\u306b\u5207\u65ad\u3057\u307e\u3059\u3002Trypsin\u81ea\u8eab\u304c\u3053\u308c\u3089\u306e\u30a2\u30df\u30ce\u9178\u3092\u6301\u3064\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u3042\u308b\u305f\u3081\u3001\u4e2d\u9577\u671f\u306e\u51b7\u8535\u4fdd\u5b58\u3084\u5ba4\u6e29\u4ee5\u4e0a\u306e\u6e29\u5ea6\u5e2f\u3067\u306e\u653e\u7f6e\u306b\u3088\u3063\u3066\u81ea\u5df1\u5206\u89e3\u3057\u3066\u6d3b\u6027\u304c\u5f90\u3005\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001Trypsin\u306f0.05\uff5e0.25 \uff05\u306e\u6fc3\u5ea6\u3067\u4f7f\u7528\u3055\u308c\u3001\u7d30\u80de\u8868\u9762\u306e\u7d30\u80de\u63a5\u7740\u5206\u5b50\u3092\u5206\u89e3\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u7d30\u80de\u3092\u89e3\u96e2\u3055\u305b\u307e\u3059\u3002Trypsin\u306e\u4f5c\u7528\u3092\u505c\u6b62\u3055\u305b\u308b\u969b\u306f\u3001FBS\uff08fetal bovine serum\uff1b\u30a6\u30b7\u80ce\u5150\u8840\u6e05\uff09\u6dfb\u52a0\u6e08\u307f\u306e\u5b8c\u5168\u57f9\u5730\u3092\u7528\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001FBS\u306b\u542b\u307e\u308c\u308bTrypsin inhibitor\u306e\u52b9\u679c\u3092\u671f\u5f85\u3057\u3066\u306e\u64cd\u4f5c\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7121\u8840\u6e05\u57f9\u5730\u3067\u306f\u5341\u5206\u306a\u52b9\u679c\u3092\u5f97\u3089\u308c\u305a\u3001\u7d30\u80de\u3092\u75db\u3081\u3066\u3057\u307e\u3046\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u7121\u8840\u6e05\u57f9\u5730\u3092\u7528\u3044\u308b\u969b\u306b\u306f\u3001Trypsin inhibitor\u3092\u5225\u9014\u6dfb\u52a0\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u5bfe\u5fdc\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5f53\u793e\u306eTrypsin inhibitor\u88fd\u54c1\u306f\u3001\u8a18\u4e8b\u306e\u6700\u5f8c\u3067\u307e\u3068\u3081\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306bTrypsin\u767b\u5834<\/h2>\n<p>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u521d\u3081\u3066Trypsin\u304c\u4f7f\u308f\u308c\u305f\u306e\u306f\u30011916\u5e74\u306b\u767a\u8868\u3055\u308c\u305fPeyton Rous\u3089\u306e\u5b9f\u9a13\u3060\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u8ad6\u6587\u306f\u30ea\u30f3\u30af\u5148\u304b\u3089\u7121\u6599\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u304d\u308b\u306e\u3067\u3001\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u539f\u6587\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<br \/>\n[\u53c2\u8003\u6587\u732e1] Rous &amp; Jones (1916) \u201cA method for obtaining suspensions of living cells from the fixed tissues, and for the plating out of individual cells.\u201d <i>The Journal of Experimental Medicine<\/i>, 23(4):549-55 (PMID: <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/19868005\/\" target=\"_blank\" rel=\"noopener\">19868005<\/a>)<\/p>\n<p>\u306a\u304a\u3001Rous\u306e\u540d\u306f\u3001\u816b\u760d\u5f62\u6210\u3092\u4fc3\u3059\u30a6\u30a4\u30eb\u30b9\u3068\u3057\u3066\u521d\u3081\u3066\u8a18\u8ff0\u3055\u308c\u305f\u300c\u30e9\u30a6\u30b9\u8089\u816b\u30a6\u30a4\u30eb\u30b9\u300d\u306b\u6b8b\u3063\u3066\u3044\u307e\u3059\u3002Rous\u306f\u3053\u306e\u30a6\u30a4\u30eb\u30b9\u306e\u767a\u898b\u306e\u696d\u7e3e\u30671966\u5e74\u306b\u30ce\u30fc\u30d9\u30eb\u751f\u7406\u5b66\u30fb\u533b\u5b66\u8cde\u3092\u53d7\u8cde\u3057\u3066\u3044\u307e\u3059\uff08<a href=\"https:\/\/www.nobelprize.org\/prizes\/medicine\/1966\/rous\/facts\/\" target=\"_blank\" rel=\"noopener\">Peyton Rous &#8211; Facts (nobelprize.org)<\/a>\uff09\u3002<\/p>\n<p>Rous\u3089\u306b\u3088\u308bTrypsin\u306e\u5b9f\u9a13\u306e\u5185\u5bb9\u306b\u5165\u308b\u524d\u306b\u3001\u57f9\u990a\u5b9f\u9a13\u306b\u3064\u3044\u3066\u5c11\u3057\u88dc\u8db3\u3055\u305b\u3066\u304f\u3060\u3055\u3044\u3002\u810a\u690e\u52d5\u7269\u3092\u6271\u3046\u751f\u7269\u5b66\u8005\u306f\u3001\u7d30\u80de\u3001\u7d44\u7e54\uff081\u7a2e\u985e\u307e\u305f\u306f\u5c11\u6570\u7a2e\u985e\u306e\u7d30\u80de\u96c6\u56e3\u306e\u6a5f\u80fd\u5358\u4f4d\uff09\u3001\u81d3\u5668\u30fb\u5668\u5b98\uff08\u8907\u6570\u306e\u7d44\u7e54\u306e\u96c6\u5408\u4f53\uff09\u3001\u500b\u4f53\uff08\u80ce\u4ed4\u306a\u3069\uff09\u306e\u57f9\u990a\u65b9\u6cd5\u306e\u958b\u767a\u306b\u9577\u5e74\u6311\u6226\u3057\u3066\u304d\u307e\u3057\u305f\u3002\u4e00\u822c\u7684\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u7acb\u4f53\u5316\u3059\u308b\u307b\u3069\u3001\u30b5\u30f3\u30d7\u30eb\u30b5\u30a4\u30ba\u304c\u5927\u304d\u304f\u306a\u308b\u307b\u3069\u3001\u5065\u5168\u306b\u57f9\u990a\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306b\u306a\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u672c\u8a18\u4e8b\u3067\u6271\u3046Rous\u3089\u306e\u7814\u7a76\u4ee5\u524d\u306f\u3001\u57f9\u990a\u5b9f\u9a13\u3068\u3044\u3048\u3070\u7d44\u7e54\u57f9\u990a\uff08Tissue culture\uff09\u306e\u3053\u3068\u3092\u6307\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u5f53\u6642\u306e\u7814\u7a76\u8005\u306f\u7d44\u7e54\u304b\u3089\u7d30\u80de\u3092\u5358\u96e2\u3059\u308b\u8853\u3092\u6301\u305f\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u57f9\u990a\u30b5\u30f3\u30d7\u30eb\u3068\u3057\u3066\u6e96\u5099\u3067\u304d\u308b\u6700\u5c0f\u5358\u4f4d\u304c\u3001\u4e00\u90e8\u3092\u9664\u3044\u3066\u3001\u89e3\u5256\u5b66\u7684\u306a\u624b\u6280\u3067\u5f97\u3089\u308c\u305f\u7d44\u7e54\u7247\u3060\u3063\u305f\u304b\u3089\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u73fe\u5728\u3067\u3082\u3001\u3044\u304f\u3064\u304b\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u7d30\u80de\u57f9\u990a\u7528\u306e\u30c7\u30a3\u30c3\u30b7\u30e5\u306e\u88fd\u54c1\u540d\u304c\u201dTissue culture dish\u201d\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u306f\u3001\u3053\u306e\u6b74\u53f2\u7684\u7d4c\u7def\u306b\u3088\u308b\u3082\u306e\u3068\u601d\u308f\u308c\u307e\u3059\u3002\u57f9\u990a\u30b5\u30f3\u30d7\u30eb\u306e\u4e00\u90e8\u306e\u4f8b\u5916\u3068\u306f\u3001\u3082\u3068\u3082\u3068\u5358\u4e00\u306e\u7d30\u80de\u3068\u3057\u3066\u751f\u4f53\u5185\u306b\u5b58\u5728\u3057\u3066\u3044\u308b\u8840\u7403\u7cfb\u306e\u7d30\u80de\u3084\u3001\u7cbe\u5b50\u306a\u3069\u3067\u3059\u3002\u591a\u7d30\u80de\u751f\u7269\u3092\u69cb\u6210\u3059\u308b\u307b\u3068\u3093\u3069\u306e\u7d30\u80de\u306f\u5468\u56f2\u306e\u7d30\u80de\u3068\u63a5\u7740\u3057\u3066\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002Trypsin\u306b\u3088\u3063\u3066\u7d30\u80de\u306e\u5358\u96e2\u30fb\u7d99\u4ee3\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u305fRous\u3089\u306e\u7814\u7a76\u306f\u3001\u57f9\u990a\u3067\u304d\u308b\u7d30\u80de\u306e\u7a2e\u985e\u3092\u5287\u7684\u306b\u5897\u3084\u3059\u304d\u3063\u304b\u3051\u3068\u306a\u3063\u305f\u3068\u8a00\u3048\u307e\u3059\u3002\u306a\u304a\u3001\u7d44\u7e54\u57f9\u990a\u306e\u8a66\u307f\u306f1800\u5e74\u4ee3\u7d42\u76e4\u306b\u59cb\u307e\u3063\u3066\u3044\u305f\u3068\u3055\u308c\u3066\u304a\u308a\u3001\u7d30\u80de\u30b7\u30fc\u30c8\u3001\u30aa\u30eb\u30ac\u30ce\u30a4\u30c9\u3001\u80ce\u4ed4\u57f9\u990a\u6cd5\u306a\u3069\u3001\u73fe\u5728\u3067\u3082\u6311\u6226\u7684\u306a\u7814\u7a76\u304c\u7d9a\u3051\u3089\u308c\u3066\u3044\u308b\u5206\u91ce\u306b\u3064\u306a\u304c\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u88dc\u8db3\u306f\u3053\u306e\u304f\u3089\u3044\u306b\u3057\u3066\u3001Rous\u3089\u306e\u8ad6\u6587\u306b\u623b\u308a\u307e\u3059\u3002<br \/>\nMethod\u306e\u7ae0\u306f\u3001\u4e3b\u5f79\u3067\u3042\u308bTrypsin\u6eb6\u6db2\u306e\u8abf\u88fd\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u3002Trypsin\u7c89\u672b\u30923\u793e\u304b\u3089\u5165\u624b\u3057\u3001\u62bd\u51fa\u65b9\u6cd5\u306e\u9055\u3044\u306b\u7531\u6765\u3059\u308b\u4e0d\u7d14\u7269\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u30661\u793e\u306e\u88fd\u54c1\u3092\u9078\u629e\u3057\u3001\u3055\u3089\u306b\u7cbe\u88fd\u3057\u305f\u5f8c\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6eb6\u304b\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u7d30\u80de\u3092\u6bba\u3055\u305a\u306b\u51e6\u7406\u3067\u304d\u308bTrypsin\u6fc3\u5ea6\u3082\u8abf\u3079\u3066\u3044\u307e\u3059\u3002Rous\u3089\u306f\u30d0\u30c3\u30d5\u30a1\u30fc\u3068\u3057\u3066Locke\u2019s Solution\uff08Ringer\u2019s Solution\u306e\u6539\u826f\u7248\uff09\u3092\u7528\u3044\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u69cb\u6210\u6210\u5206\u306f\u3001\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\uff08NaCl\uff09\u3001\u5869\u5316\u30ab\u30ea\u30a6\u30e0\uff08KCl\uff09\u3001\u30ea\u30f3\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\uff08NaH<sub>2<\/sub>PO<sub>4<\/sub>\uff09\u3001\u5869\u5316\u30ab\u30eb\u30b7\u30a6\u30e0\uff08CaCl<sub>2<\/sub>\uff09\u3001\u305d\u3057\u3066\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\uff08NaHCO<sub>3<\/sub>\uff09\u3067\u3059\u3002\u63a5\u7740\u7d30\u80de\u306e\u57f9\u990a\u7d4c\u9a13\u8005\u306a\u3089\u3070\u3001\u3053\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u7d44\u6210\u306b\u5f15\u3063\u304b\u304b\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u306e\u5f15\u3063\u304b\u304b\u308a\u306b\u3064\u3044\u3066\u306f\u5f8c\u8ff0\u3057\u307e\u3059\u3002<\/p>\n<p>\u6a39\u7acb\u3055\u308c\u305f\u682a\u7d30\u80de\u306e\u57f9\u990a\u3068\u533a\u5225\u3057\u3066\u3001\u7d44\u7e54\u304b\u3089\u53d6\u308a\u51fa\u3057\u305f\u7d30\u80de\u3092\u57f9\u990a\u3059\u308b\u3053\u3068\u3092\u521d\u4ee3\u57f9\u990a\u3068\u547c\u3073\u307e\u3059\u3002\u73fe\u5728\u3067\u306f\u3001\u6458\u51fa\u3057\u305f\u7d44\u7e54\u304b\u3089\u7d30\u80de\u3092\u76f4\u63a5\u5358\u96e2\u3057\u3066\u30c7\u30a3\u30c3\u30b7\u30e5\u306a\u3069\u306b\u64ad\u7a2e\u3059\u308b\u624b\u6cd5\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u4e00\u65b9\u3053\u306e\u8ad6\u6587\u3067\u306f\u3001\u63a1\u53d6\u3057\u305f\u591a\u6570\u306e\u7d44\u7e54\u7247\u3092\u30da\u30c8\u30ea\u30c7\u30a3\u30c3\u30b7\u30e5\u3067\u3057\u3070\u3089\u304f\u57f9\u990a\u3059\u308b\u3068\u3044\u3046\u3001\u7d44\u7e54\u7247\u306e\u4fee\u5fa9\u30b9\u30c6\u30c3\u30d7\u3092\u8a2d\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u672c\u6587\u304b\u3089\u306f\u8aad\u307f\u53d6\u308a\u3065\u3089\u3044\u306e\u3067\u3059\u304c\u3001\u30c7\u30a3\u30c3\u30b7\u30e5\u306b\u8cbc\u308a\u3064\u3044\u305f\u7d44\u7e54\u7247\u306e\u5468\u56f2\u304b\u3089\u7d30\u80de\u304c\u751f\u3048\u51fa\u3059\u73fe\u8c61\u3092\u201d\u4fee\u5fa9\u201d\u306e\u6307\u6a19\u3068\u3057\u305f\u3088\u3046\u3067\u3059\u3002\u8ad6\u6587\u306e\u30bf\u30a4\u30c8\u30eb\u306b\u3042\u308b\u201dfixed tissue\u201d\u306f\u3001\u3053\u306e\u201d\u4fee\u5fa9\u3055\u308c\u305f\u7d44\u7e54\u7247\u201d\u3092\u6307\u3057\u3066\u3044\u308b\u3068\u601d\u308f\u308c\u307e\u3059\u3002\u7b46\u8005\u3068\u540c\u69d8\u3001\u30db\u30eb\u30de\u30ea\u30f3\u306a\u3069\u306b\u3088\u308b\u201d\u56fa\u5b9a\u201d\u3092\u30a4\u30e1\u30fc\u30b8\u3057\u305f\u65b9\u3082\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u56fa\u5b9a\u5f8c\u306e\u7d30\u80de\u3092\u57f9\u990a\u3059\u308b\u3053\u3068\u306f\u73fe\u4ee3\u3067\u3082\u4e0d\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u201d\u4fee\u5fa9\u201d\u30b9\u30c6\u30c3\u30d7\u306b\u7528\u3044\u305f\u57f9\u990a\u6db2\u306f\u3001\u8840\u6f3f\u3068Locke\u2019s Solution\u30921\uff1a3\u3067\u6df7\u5408\u3057\u305f\u6eb6\u6db2\u3067\u3059\u3002Rous\u3089\u306f\u3053\u306e\u6eb6\u6db2\u304c\u591a\u304f\u306e\u7d44\u7e54\u306b\u9069\u3057\u3066\u3044\u308b\u3068\u30b3\u30e1\u30f3\u30c8\u3057\u3066\u3044\u307e\u3059\u3002\u306a\u304a\u3001\u8840\u6f3f\u3092\u63a1\u53d6\u3057\u305f\u52d5\u7269\u7a2e\u306b\u3064\u3044\u3066\u306f\u8a18\u8ff0\u304c\u3042\u308a\u307e\u305b\u3093\u3002\u57f9\u5730\u3092\u4f7f\u3048\u3070\u3044\u3044\u306e\u306b\u3068\u8003\u3048\u305f\u65b9\u3082\u304a\u3089\u308c\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u73fe\u5728\u306e\u7814\u7a76\u8005\u304c\u4f7f\u3063\u3066\u3044\u308b\u57fa\u790e\u57f9\u5730\u306e\u539f\u578b\u304c\u767a\u660e\u3055\u308c\u305f\u306e\u306f\u3001\u3053\u306e\u8ad6\u6587\u306e\u767a\u8868\u304b\u308930\u5e74\u4ee5\u4e0a\u3082\u5148\u306a\u306e\u3067\u3059\u3002\u57fa\u790e\u57f9\u5730\u306e\u958b\u767a\u306e\u6b74\u53f2\u306b\u8208\u5473\u304c\u3042\u308b\u65b9\u306f\u3001\u95a2\u9023\u8a18\u4e8b\u306e\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff08<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment-2-bid-ts\/?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u790e\u57f9\u5730\u306e\u4e16\u754c<\/a>\uff09\u3002<\/p>\n<p>\u3055\u3066\u300137\u2103\u306b\u6e29\u3081\u305fTrypsin\u6eb6\u6db2\u3092\u201d\u4fee\u5fa9\u201d\u3055\u308c\u305f\u7d44\u7e54\u306b\u52a0\u3048\u3066\u3057\u3070\u3089\u304f\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30c8\u3057\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u3088\u3063\u3066\u7d44\u7e54\u3092\u7834\u7815\u3057\u305f\u5f8c\u3001\u6ec5\u83cc\u30ac\u30fc\u30bc\u3067\u308d\u904e\u3057\u3066\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u56de\u53ce\u3057\u3066\u3044\u307e\u3059\u3002Rous\u3089\u306f\u3001\u307b\u307c\u5168\u3066\u306e\u7d30\u80de\u304c\u751f\u304d\u3066\u3044\u305f\u3068\u30b3\u30e1\u30f3\u30c8\u3057\u3066\u3044\u307e\u3059\u3002\u9060\u5fc3\u3057\u3066\u5f97\u305f\u7d30\u80de\u3092\u524d\u8ff0\u306e\u57f9\u990a\u6db2\u3067\u61f8\u6fc1\u3057\u3001\u30da\u30c8\u30ea\u30c7\u30a3\u30c3\u30b7\u30e5\u306b\u64ad\u7a2e\u3057\u3066\u57f9\u990a\u3057\u307e\u3057\u305f\u3002\u8ad6\u6587\u306b\u306f\u3001\u7d44\u7e54\u7247\u304b\u3089\u751f\u3048\u51fa\u3057\u305f\u7d30\u80de\u306e\u5199\u771f\u3084\u3001\u57f9\u990a\u5f8c\u306e\u7d30\u80de\u306e\u30b9\u30b1\u30c3\u30c1\u30fb\u5199\u771f\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4f4d\u76f8\u5dee\u9855\u5fae\u93e1\u304c\u7121\u3044\u6642\u4ee3\u306b\u3001\u3069\u306e\u3088\u3046\u306b\u3057\u3066\u5199\u771f\u3092\u64ae\u5f71\u3057\u305f\u306e\u304b\u306b\u3082\u8208\u5473\u304c\u3042\u308b\u306e\u3067\u3059\u304c\u3001\u6b8b\u5ff5\u306a\u304c\u3089\u5199\u771f\u64ae\u5f71\u306b\u95a2\u3059\u308b\u8a18\u8ff0\u306f\u3042\u308a\u307e\u305b\u3093\uff08\u4f4d\u76f8\u5dee\u9855\u5fae\u93e1\u304c\u767a\u660e\u3055\u308c\u305f\u306e\u306f1932\u5e74\u3001\u88fd\u54c1\u5316\u306f1943\u5e74\u3068\u3055\u308c\u3066\u3044\u308b\uff09\u3002<\/p>\n<p>Rous\u3089\u306f\u3001\u30e9\u30c3\u30c8\u3068\u30cb\u30ef\u30c8\u30ea\u306e\u80ce\u4ed4\u7d44\u7e54\u3084\u816b\u760d\u3001\u82e5\u3044\u30e9\u30c3\u30c8\u306e\u7d44\u7e54\u3092\u7528\u3044\u3066\u3001Trypsin\u306b\u3088\u308b\u7d30\u80de\u306e\u53d6\u5f97\u306b\u6210\u529f\u3057\u305f\u3068\u8a18\u8ff0\u3057\u3066\u3044\u307e\u3059\u3002\u7d50\u5408\u7d44\u7e54\u306e\u7d30\u80de\u3001\u5185\u76ae\u7d30\u80de(?)\u3001\u8108\u7d61\u819c\u306e\u7d30\u80de\u3001\u8089\u816b\u7d30\u80de\u3001\u813e\u81d3\u7d44\u7e54\u306e\u7d30\u80de\u3067\u8a66\u3057\u305f\u305d\u3046\u3067\u3059\uff08\u6ce8\uff1a\u672c\u6587\u306b\u201d(?)\u201d\u3068\u8a18\u8ff0\uff09\u3002\u305d\u3057\u3066\u3001Rous\u3089\u304c\u8a18\u8ff0\u3057\u305f\u6b21\u306e\u6587\u7ae0\u3082\u91cd\u8981\u306a\u6307\u6458\u3067\u3059\u3002\u300cSheets of growing cells (epithelium) are not readily broken up. Whether individual epithelial cells can be liberated in this way is a yet uncertain.\u300d\u8981\u7d04\u3059\u308c\u3070\u3001\u300cTrypsin\u51e6\u7406\u306b\u3088\u3063\u3066\u4e0a\u76ae\u7d44\u7e54\u3092\u5206\u6563\u3055\u305b\u3066\u7d30\u80de\u3092\u5f97\u3089\u308c\u308b\u304b\u3069\u3046\u304b\u306f\u307e\u3060\u308f\u304b\u3089\u306a\u3044\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3057\u3087\u3046\u3002100\u5e74\u5f8c\u306b\u751f\u304d\u3066\u3044\u308b\u79c1\u305f\u3061\u306f\u3001\u3053\u306e\u7591\u554f\u306b\u5bfe\u3059\u308b\u30d2\u30f3\u30c8\u3092\u77e5\u3063\u3066\u3044\u307e\u3059\u3002\u3059\u306a\u308f\u3061\u3001\u3053\u306e\u5b9f\u9a13\u306b\u7528\u3044\u3089\u308c\u305fTrypsin\u6eb6\u6db2\u306b\u542b\u307e\u308c\u308b\u30ab\u30eb\u30b7\u30a6\u30e0\u30a4\u30aa\u30f3\u3092\u9664\u53bb\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u308c\u304c\u3001\u4e0a\u8ff0\u3057\u305f\u30d0\u30c3\u30d5\u30a1\u30fc\u7d44\u6210\u3078\u306e\u5f15\u3063\u304b\u304b\u308a\u306b\u5bfe\u3059\u308b\u56de\u7b54\u3067\u3059\u3002<\/p>\n<h2>Trypsin\u3092\u4f7f\u3063\u3066\u7d30\u80de\u3092\u7d99\u4ee3\u3059\u308b<\/h2>\n<p>\u9a5a\u3044\u305f\u3053\u3068\u306b\u3001\u540c\u8ad6\u6587\u3067Rous\u3089\u306f\u3001\u7d44\u7e54\u304b\u3089\u7d30\u80de\u306e\u53d6\u5f97\u3060\u3051\u3067\u306a\u304f\u3001\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u3082Trypsin\u3092\u5fdc\u7528\u3067\u304d\u308b\u3053\u3068\u307e\u3067\u5831\u544a\u3057\u3066\u3044\u307e\u3059\u3002Rous\u3089\u306fTrypsin\u3092\u7528\u3044\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30cb\u30ef\u30c8\u30ea\u306e\u8108\u7d61\u819c\u304b\u3089\u5f97\u305f\u521d\u4ee3\u57f9\u990a\u7d30\u80de\u3092\u5c11\u306a\u304f\u3068\u30822\u56de\u7d99\u4ee3\u3067\u304d\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u89e3\u96e2\u3055\u305b\u305f\u7d30\u80de\u3092\u64ad\u7a2e\u3059\u308b\u3068\u307e\u3082\u306a\u304f\u9806\u8abf\u306b\u5897\u6b96\u3057\u3001\u305d\u306e\u9593\u306f\u7d30\u80de\u304c\u6b63\u5e38\u3067\u3042\u308b\uff08\u7d30\u80de\u306e\u5f62\u614b\u3092\u6307\u6a19\u3068\u3057\u3066\u3044\u308b\u3068\u601d\u308f\u308c\u308b\uff09\u304c\u300124\u6642\u9593\u306a\u3044\u3057\u306f48\u6642\u9593\u5f8c\u306b\u306f\u7570\u5e38\u306a\u7d30\u80de\u304c\u51fa\u73fe\u3059\u308b\u3068\u8a18\u8ff0\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u89b3\u5bdf\u304b\u3089\u3001Rous\u3089\u306f\u5c11\u306a\u304f\u3068\u308248\u6642\u9593\u4ee5\u5185\u306b\u7d30\u80de\u3092\u7d99\u4ee3\u3059\u3079\u304d\u3067\u3042\u308b\u3053\u3068\u3092\u63d0\u6848\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u73fe\u5728\u306e\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306e\u6a19\u6e96\u7684\u306a\u6280\u6cd5\u306e\u3072\u3068\u3064\u3067\u3042\u308b\u3001\u7d30\u80de\u304c\u30aa\u30fc\u30d0\u30fc\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306b\u9054\u3059\u308b\u524d\u306b\u7d99\u4ee3\u3059\u308b\u3053\u3068\u3078\u306e\u53f2\u4e0a\u521d\u306e\u6ce8\u610f\u559a\u8d77\u3060\u3068\u601d\u308f\u308c\u307e\u3059\u3002<\/p>\n<p>\u8ad6\u6587\u306e\u6700\u5f8c\u306e\u7ae0\u3067\u3042\u308b\u300cTechnical Difficulties\u300d\u306e\u7ae0\u3067\u3001Rous\u3089\u304c\u3053\u306e\u624b\u6cd5\u3092\u78ba\u7acb\u3059\u308b\u904e\u7a0b\u3067\u5de5\u592b\u3057\u305f\u70b9\u3084\u958b\u767a\u3057\u305f\u9053\u5177\u306a\u3069\uff08\u57f9\u990a\u64cd\u4f5c\u3092\u884c\u3046\u7a7a\u9593\u3065\u304f\u308a\u3084\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\uff09\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6297\u751f\u7269\u8cea\u304c\u5b58\u5728\u3057\u3066\u3044\u306a\u3044\u6642\u4ee3\u3067\u3059\u304b\u3089\u3001\u308f\u305a\u304b\u306a\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u304c\u4e00\u9023\u306e\u57f9\u990a\u3092\u58ca\u6ec5\u3055\u305b\u305f\u3053\u3068\u3067\u3057\u3087\u3046\uff08\u6700\u521d\u306e\u6297\u751f\u7269\u8cea\u30da\u30cb\u30b7\u30ea\u30f3\u306e\u767a\u8868\u306f1929\u5e74\uff09\u3002\u73fe\u5728\u3067\u306f\u7c21\u5358\u306b\u5165\u624b\u3067\u304d\u308b\u5b9f\u9a13\u5668\u5177\u3092\u624b\u4f5c\u308a\u3057\u3066\u3044\u308b\u904e\u7a0b\u3092\u57a3\u9593\u898b\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u307e\u3055\u306b\u958b\u62d3\u8005\u306e\u8ad6\u6587\u3067\u3042\u308b\u3053\u3068\u3092\u611f\u3058\u3055\u305b\u307e\u3059\u3002<\/p>\n<p>\u4ee5\u4e0a\u3001\u524d\u7de8\u3067\u306f\u3001Trypsin\u3092\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u521d\u3081\u3066\u5fdc\u7528\u3057\u305f\u8ad6\u6587\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_2_bid_ts_2\/?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5f8c\u7de8<\/a>\u3067\u306f\u3001EDTA\u3084\u3001Trypsin-EDTA\u306e\u521d\u767b\u5834\u3001\u305d\u3057\u3066\u3001\u7d30\u80de\u63a5\u7740\u5206\u5b50\u30ab\u30c9\u30d8\u30ea\u30f3\u306e\u767a\u898b\u306b\u95a2\u3059\u308b\u8ad6\u6587\u3092\u53d6\u308a\u4e0a\u3052\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u306a\u304a\u3001\u5f53\u793e\u3067\u8ca9\u58f2\u3057\u3066\u3044\u308b\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3092\u4ee5\u4e0b\u3067\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3001\u3054\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u30bf\u30a4\u30d7\u5225\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u306e\u3054\u7d39\u4ecb<\/h2>\n<p><b>(1) \u4e3b\u3068\u3057\u3066\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3059\u308b\u9175\u7d20\u7cfb\u8a66\u85ac<\/b><br \/>\n\u25a0Gibco\u2122 Trypsin-EDTA\u30b7\u30ea\u30fc\u30ba\uff08\u5e83\u7bc4\u56f2\u306e\u57f9\u990a\u7d30\u80de\u306b\u9069\u7528\uff09<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/reagents\/trypsin\/trypsin.html?icid=cvc-dissociation-c1t2?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Trypsin\u3001Trypsin EDTA<\/a><br \/>\n\u25a0Gibco\u2122 TrypLE\u30b7\u30ea\u30fc\u30ba\uff08\u5e83\u7bc4\u56f2\u306e\u57f9\u990a\u7d30\u80de\u306b\u9069\u7528\uff09<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-culture\/mammalian-cell-culture\/reagents\/trypsin\/tryple-express.html?icid=cvc-dissociation-c2t2?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">TrypLE Express\u304a\u3088\u3073TrypLE Select <\/a><br \/>\n\u25a0Gibco\u2122 StemPro\u2122 Accutase\u2122\u30b7\u30ea\u30fc\u30ba\uff08\u5e79\u7d30\u80de\u30fb\u521d\u4ee3\u7d30\u80de\u7b49\u306b\u9069\u7528\uff09<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/stem-cell-research\/stem-cell-culture\/stem-cell-research-misc\/stempro-accutase.html?icid=cvc-dissociation-c4t2?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">StemPro Accutase <\/a><\/p>\n<p>TrypLE\u30b7\u30ea\u30fc\u30ba\u306f\u3001Trypsin-EDTA\u306e\u4e0a\u4f4d\u4e92\u63db\u3068\u8a00\u3048\u308b\u8a66\u85ac\u3067\u3059\u3002Trypsin-EDTA\u306e\u4ee3\u66ff\u54c1\u3068\u3057\u3066\u4f7f\u7528\u3067\u304d\u308b\u307b\u304b\u3001Animal origin free\u306a\u3069\u3001\u81e8\u5e8a\u7814\u7a76\u3078\u306e\u5c55\u958b\u306b\u3082\u8003\u616e\u3055\u308c\u305f\u88fd\u54c1\u3067\u3059\u3002StemPro Accutase\u30b7\u30ea\u30fc\u30ba\u306f\u3001\u30d2\u30c8ES\u7d30\u80de\u306a\u3069\u306e\u5e79\u7d30\u80de\u3084\u521d\u4ee3\u57f9\u990a\u7d30\u80de\u306a\u3069\u306e\u654f\u611f\u306a\u7d30\u80de\u306e\u89e3\u96e2\u7528\u3068\u3057\u3066\u4f7f\u7528\u3067\u304d\u308b\u88fd\u54c1\u3067\u3059\u3002<\/p>\n<p><b>(2) \u4e3b\u3068\u3057\u3066\u7d44\u7e54\u304b\u3089\u306e\u7d30\u80de\u306e\u5358\u96e2\u306b\u4f7f\u7528\u3059\u308b\u9175\u7d20\u7cfb\u8a66\u85ac<\/b><br \/>\n\u25a0Collagenase\u30b7\u30ea\u30fc\u30ba<br \/>\nGibco\u2122 Collagenase Type I\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/17018029?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Collagenase, Type I, powder <\/a>\uff09<br \/>\nGibco\u2122 Collagenase Type II\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/17101015?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Collagenase, Type II, powder <\/a>\uff09<br \/>\nGibco\u2122 Collagenase Type IV\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/17104019?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Collagenase, Type IV, powder <\/a>\uff09<br \/>\n\u25a0Gibco\u2122 Dispase II\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/17105041?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Dispase II, powder <\/a>\uff09<br \/>\n\u25a0Gibco\u2122 Trypsin\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/27250018?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Trypsin (1:250), powder <\/a>\uff09<\/p>\n<p><b>(3) \u975e\u9175\u7d20\u7684\u306b\u7d30\u80de\u3092\u5358\u96e2\u3059\u308b\u30ad\u30ec\u30fc\u30c8\u542b\u6709\u5e73\u8861\u5869\u985e\u6eb6\u6db2<\/b><br \/>\n\u25a0Gibco\u2122 Cell Dissociation Buffer, enzyme-free, PBS<br \/>\n\u25a0Gibco\u2122 Cell Dissociation Buffer, enzyme-free, Hanks&#8217; Balanced Salt Solution<br \/>\n\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/references\/gibco-cell-culture-basics\/cell-culture-protocols\/cell-dissociation-protocol.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Dissociation of Cells from Culture Vessels with Enzyme-free Cell Dissociation Buffers | Thermo Fisher Scientific &#8211; JP<\/a>\uff09<br \/>\n\u25a0Gibco\u2122 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/15040066?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Versene Solution (thermofisher.com)<\/a><\/p>\n<p>Gibco\u2122 Cell Dissociation Buffer\u306fEDTA\u3092\u542b\u6709\u3059\u308b\u5e73\u8861\u5869\u985e\u6eb6\u6db2\u3067\u3042\u308a\u3001PBS\u30d9\u30fc\u30b9\u3068HBSS\u30d9\u30fc\u30b9\u306e\u88fd\u54c1\u3092\u8ca9\u58f2\u3057\u3066\u3044\u307e\u3059\u3002Trypsin\u306e\u3088\u3046\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u306e\u6d3b\u6027\u3067\u306f\u306a\u304f\u3001EDTA\u306e\u30ad\u30ec\u30fc\u30c8\u4f5c\u7528\u3067\u7d30\u80de\u63a5\u7740\u3092\u5f31\u3081\u3066\u63a5\u7740\u7d30\u80de\u3092\u89e3\u96e2\u3055\u305b\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7d30\u80de\u8868\u9762\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u4fdd\u6301\u3057\u305f\u307e\u307e\u306e\u7d30\u80de\u3092\u53d6\u5f97\u3067\u304d\u308b\u306e\u3067\u3001\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3084\u514d\u75ab\u67d3\u8272\u306a\u3069\u306b\u3088\u308b\u7d30\u80de\u8868\u9762\u5206\u5b50\u306e\u89e3\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001\u7d30\u80de\u89e3\u96e2\u4f5c\u7528\u306f\u7a4f\u3084\u304b\u306a\u305f\u3081\u3001Hela\u7d30\u80de\u3084NIH 3T3\u7d30\u80de\u306a\u3069\u3001\u63a5\u7740\u529b\u304c\u6bd4\u8f03\u7684\u5f31\u3044\u7d30\u80de\u306b\u306e\u307f\u9069\u7528\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u7d30\u80de\u306e\u7d99\u4ee3\u7528\u3068\u3057\u3066Versene Solution\u3068\u3044\u3046EDTA\u6eb6\u6db2\u3082\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><b>(4) Trypsin inhibitor\u88fd\u54c1<\/b><br \/>\n\u25a0Gibco\u2122 Defined Trypsin Inhibitor\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/R007100?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Defined Trypsin Inhibitor <\/a>\uff09<br \/>\n\u25a0Gibco\u2122 Soybean Trypsin Inhibitor, powder\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/17075029?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Soybean Trypsin Inhibitor, powder <\/a>\uff09<br \/>\n\u25a0Gibco\u2122 Trypsin Neutralizer Solution\uff08<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/R002100?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Trypsin Neutralizer Solution <\/a>\uff09<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbTrypsin-EDTA\u3092\u306f\u3058\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u30bf\u30a4\u30d7\u306e\u7d30\u80de\u89e3\u96e2\u85ac\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u30fb1916\u5e74\u3001\u7d44\u7e54\u304b\u3089\u7d30\u80de\u3092\u5358\u96e2\u3057\u3066\u57f9\u990a\u3001\u7d99\u4ee3\u3059\u308b\u76ee\u7684\u3067\u521d\u3081\u3066Trypsin\u304c\u4f7f\u308f\u308c\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u57f9\u990a\u5b9f\u9a13\u3078\u306eTrypsin\u306e\u5fdc\u7528\u306f\u3001\u63a5\u7740\u7d30\u80de\u306e\u57f9\u990a\u5b9f\u9a13\u306e\u53ef\u80fd\u6027\u3092\u5927\u304d\u304f\u5e83\u3052\u307e\u3057\u305f\u3002<\/p>\n<h3>3D\u7d30\u80de\u57f9\u990a\uff06\u89e3\u6790\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\uff08\u82f1\u8a9e\u7248\uff09\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h3>\n<p>\u30b9\u30d5\u30a7\u30ed\u30a4\u30c9\u30fb\u30aa\u30eb\u30ac\u30ce\u30a4\u30c9\u306a\u3069\u306e3D\u7d30\u80de\u57f9\u990a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u30023D\u57f9\u990a\u306b\u4f7f\u7528\u3055\u308c\u308b\u7d30\u80de\u7a2e\u304b\u3089\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\uff08\u8db3\u5834\u6750\u6599\uff09\u3084\u57f9\u5730\u3068\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3001\u753b\u50cf\u89e3\u6790\u306e\u624b\u6cd5\u3084\u75be\u60a3\u30e2\u30c7\u30eb\u3001\u751f\u7406\u5b66\u7684\u89e3\u6790\u307e\u3067\u3092\u5e83\u304f\u30ab\u30d0\u30fc\u3057\u305f\u5185\u5bb9\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u30022D\u30e2\u30c7\u30eb\u304b\u30893D\u30e2\u30c7\u30eb\u3078\u306e\u79fb\u884c\u30843D\u30e2\u30c7\u30eb\u306e\u3055\u3089\u306a\u308b\u6539\u826f\u306b\u662f\u975e\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/download-3d-cell-culture-analysis-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Gibco\u7d30\u80de\u57f9\u990a\u57fa\u790e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p>\u7d30\u80de\u57f9\u990a\u306b\u95a2\u3059\u308b\u57fa\u790e\u60c5\u5831\u3092\u89e3\u8aac\u3057\u305f\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u65e5\u672c\u8a9e\u7248\u3001\u7d04100\u30da\u30fc\u30b8\uff09\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_culture_history_1_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u7528\u3044\u305f\u5b9f\u9a13\u3067\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3068\u5e73\u8861\u5869\u985e\u6eb6\u6db2\uff08\u30d0\u30c3\u30d5\u30a1\u30fc\uff09\u306b\u52a0\u3048\u3066\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u304c\u5fc5\u8981\u3067\u3059\u30022022\u5e74\u306b60\u5468\u5e74\u3092\u8fce\u3048\u305fGibco\u2122\u30d6\u30e9\u30f3\u30c9\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3084\u8840\u6e05\u3001\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3001\u5404\u7a2e\u30d0\u30c3\u30d5\u30a1\u30fc\u306a\u3069<\/p>\n","protected":false},"author":975,"featured_media":13030,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":["post-12549","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-cell-culture","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09\" \/>\n<meta property=\"og:description\" content=\"\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u7528\u3044\u305f\u5b9f\u9a13\u3067\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3068\u5e73\u8861\u5869\u985e\u6eb6\u6db2\uff08\u30d0\u30c3\u30d5\u30a1\u30fc\uff09\u306b\u52a0\u3048\u3066\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u304c\u5fc5\u8981\u3067\u3059\u30022022\u5e74\u306b60\u5468\u5e74\u3092\u8fce\u3048\u305fGibco\u2122\u30d6\u30e9\u30f3\u30c9\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3084\u8840\u6e05\u3001\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3001\u5404\u7a2e\u30d0\u30c3\u30d5\u30a1\u30fc\u306a\u3069\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-06T00:26:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T07:17:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"608\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"20\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09\",\"datePublished\":\"2022-09-06T00:26:57+00:00\",\"dateModified\":\"2024-12-25T07:17:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/\"},\"wordCount\":317,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/shutterstock_1156778617.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/\",\"name\":\"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/shutterstock_1156778617.jpg\",\"datePublished\":\"2022-09-06T00:26:57+00:00\",\"dateModified\":\"2024-12-25T07:17:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/shutterstock_1156778617.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/shutterstock_1156778617.jpg\",\"width\":1000,\"height\":608},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell_culture_history_1_bid_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09","og_description":"\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u7528\u3044\u305f\u5b9f\u9a13\u3067\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3068\u5e73\u8861\u5869\u985e\u6eb6\u6db2\uff08\u30d0\u30c3\u30d5\u30a1\u30fc\uff09\u306b\u52a0\u3048\u3066\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u304c\u5fc5\u8981\u3067\u3059\u30022022\u5e74\u306b60\u5468\u5e74\u3092\u8fce\u3048\u305fGibco\u2122\u30d6\u30e9\u30f3\u30c9\u306f\u3001\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\u3084\u8840\u6e05\u3001\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u3001\u5404\u7a2e\u30d0\u30c3\u30d5\u30a1\u30fc\u306a\u3069","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-09-06T00:26:57+00:00","article_modified_time":"2024-12-25T07:17:41+00:00","og_image":[{"width":1000,"height":608,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"20\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09","datePublished":"2022-09-06T00:26:57+00:00","dateModified":"2024-12-25T07:17:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/"},"wordCount":317,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/","name":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","datePublished":"2022-09-06T00:26:57+00:00","dateModified":"2024-12-25T07:17:41+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","width":1000,"height":608},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u7d30\u80de\u306e\u57f9\u990a\u3068\u7d99\u4ee3\u306e\u30eb\u30fc\u30c4\u3092\u63a2\u3063\u3066\u307f\u305f\u4ef6\uff08\u524d\u7de8\uff09"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg",760,462,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":65,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":12549,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":12549,"position":1},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":12549,"position":2},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25723,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26031\/","url_meta":{"origin":12549,"position":3},"title":"\u3010\u7b2c4\u56de\u3011CHO\u7d30\u80de\u682a\u958b\u767a\u3092\u3088\u308a\u8fc5\u901f\u306b\u2015\u9ad8\u751f\u7523\u6027\u30fb\u9577\u671f\u5b89\u5b9a\u6027\u30fb\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3092\u8a55\u4fa1\u3057\u305fCHOvantage GS CLD Kit","author":"LatB Staff","date":"2026\u5e7411\u67086\u65e5","format":false,"excerpt":"\u6297\u4f53\u533b\u85ac\u54c1\u306e\u958b\u767a\u3067\u306f\u3001\u76ee\u7684\u306e\u6297\u4f53\u3092\u300c\u305f\u304f\u3055\u3093\u4f5c\u308c\u308b\u300d\u7d30\u80de\u3092\u898b\u3064\u3051\u308b\u3060\u3051\u3067\u306f\u5341\u5206\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u9ad8\u3044\u751f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/10\/cell-culture-basic-cell-culture-bpg-26031_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20129,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25016\/","url_meta":{"origin":12549,"position":4},"title":"\u3010\u7b2c2\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce","author":"LatB Staff","date":"2026\u5e744\u670828\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u64cd\u4f5c\u3067\u5f79\u7acb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u56de\u53ce\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0f\u80de\u4f53\u30b5\u30a4\u30ba","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/251d14a615127ecd8e0dac1beeb32074.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":12549,"position":5},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/shutterstock_1156778617.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12549"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12549\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13030"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12549"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}