{"id":12636,"date":"2022-09-29T11:33:46","date_gmt":"2022-09-29T02:33:46","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12636"},"modified":"2024-09-18T16:20:16","modified_gmt":"2024-09-18T07:20:16","slug":"ce_basic_dna_gsd_ts_2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/","title":{"rendered":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e"},"content":{"rendered":"<p>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n<p>DNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u304c\u958b\u767a\u30fb\u767a\u8868\u3055\u308c\u3066\u304b\u308940\u5e74\u4ee5\u4e0a\u7d4c\u904e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3044\u307e\u3060\u306b\u591a\u304f\u306e\u7814\u7a76\u5206\u91ce\u3067\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30b7\u30ea\u30fc\u30ba\u306e1\u56de\u76ee\u3067\u3042\u308b\u672c\u8a18\u4e8b\u3067\u306f\u3001DNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c8\u3068\u3057\u3066\u53d7\u3051\u5165\u308c\u3089\u308c\u3066\u304d\u305f\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u6b74\u53f2\u3068\u3001\u305d\u306e\u6b63\u78ba\u6027\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p><b>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e\u3092\u304a\u3055\u3089\u3044\u3057\u305f\u3044\u65b9<br \/>\n\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3057\u3066\u3044\u308b\u304c\u3001\u6539\u3081\u3066\u305d\u306e\u539f\u7406\u3092\u4eba\u306b\u805e\u304d\u305f\u3044\u65b9<br \/>\n\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u904e\u53bb\u306e\u601d\u3044\u51fa\u306b\u6d78\u308a\u305f\u3044\u65b9<\/p>\n<h2>\u30b5\u30f3\u30ac\u30fc\u6cd5\u3068RI\u3092\u7528\u3044\u305fDNA\u30b7\u30fc\u30b1\u30f3\u30b9<\/h2>\n<p>1977\u5e74\u3001DNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u3067\u3042\u308b\u30b8\u30c7\u30aa\u30ad\u30b7\u6cd5\u304cFred Sanger\u6c0f\u306b\u3088\u308a\u767a\u8868\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u306e\u30b8\u30c7\u30aa\u30ad\u30b7\u6cd5\u3092\u958b\u767a\u3057\u305f\u529f\u7e3e\u306b\u3088\u308a\u3001Sanger\u6c0f\u306f\u30ce\u30fc\u30d9\u30eb\u5316\u5b66\u8cde\u3092\u6388\u4e0e\u3055\u308c\u307e\u3057\u305f\uff08\u5225\u306eDNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u3067\u3042\u308b\u30de\u30af\u30b5\u30e0-\u30ae\u30eb\u30d0\u30fc\u30c8\u6cd5\u3092\u958b\u767a\u3057\u305fPaul Berg\u6c0f\u3068Walter Gilbert\u6c0f\u3068\u306e\u5171\u540c\u53d7\u8cde\uff09\u3002<\/p>\n<p>\u30b8\u30c7\u30aa\u30ad\u30b7\u6cd5\uff1d\u300c\u30b5\u30f3\u30ac\u30fc\u6cd5\u300d\u306f\u3001\u81ea\u7136\u306b\u3042\u308bDNA\u5408\u6210\u3092\u6a21\u5023\u3059\u308b\u751f\u5316\u5b66\u7684\u306a\u65b9\u6cd5\u3067\u3042\u308b\u305f\u3081\u3001\u5371\u967a\u306a\u5316\u5b66\u7269\u8cea\u3092\u4f7f\u7528\u3057\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u305d\u306e\u4f7f\u3044\u3084\u3059\u3055\u304b\u3089\u3001\u30b5\u30f3\u30ac\u30fc\u6cd5\u306fDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u6a19\u6e96\u6cd5\u3068\u306a\u3063\u3066\u3044\u304d\u307e\u3057\u305f\u3002<\/p>\n<p>\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\uff08\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u4e09\u30ea\u30f3\u9178\uff1adNTP\uff09\u3068\u4fee\u98fe\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\uff08\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u4e09\u30ea\u30f3\u9178\uff1addNTP\uff09\u306e\u6df7\u5408\u7269\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u3088\u308bDNA\u5408\u6210\u306e\u904e\u7a0b\u3067\u3001\u30e9\u30f3\u30c0\u30e0\u306bddNTP\u304c\u53d6\u308a\u8fbc\u307e\u308c\u307e\u3059\u3002DNA\u5408\u6210\u3092\u7d99\u7d9a\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a3&#8242;-\u30d2\u30c9\u30ed\u30ad\u30b7\u57fa\u304cddNTP\u306b\u306f\u7121\u3044\u305f\u3081\uff08\u3057\u305f\u304c\u3063\u3066\u300c\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u300d\u3068\u306a\u308b\uff09\u3001\u305d\u306e\u5206\u5b50\u304c\u53d6\u308a\u8fbc\u307e\u308c\u305f\u5f8c\u306e\u5408\u6210\u306f\u505c\u6b62\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u53cd\u5fdc\u5f8c\u306e\u53cd\u5fdc\u6db2\u4e2d\u306b\u306f\u3001\u7570\u306a\u308b\u30b5\u30a4\u30ba\u306e\u751f\u6210\u7269\u304c\u6df7\u5408\u3055\u308c\u305f\u72b6\u614b\u3067\u5b58\u5728\u3059\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>1985\u5e74\u306b\u958b\u767a\u3055\u308c\u305fPCR\u6cd5\u306f\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30d7\u30ed\u30bb\u30b9\uff08\u3044\u308f\u3086\u308b\u300c\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u300d\uff09\u306b\u3059\u3050\u306b\u5229\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u9ad8\u30ac\u30f3\u30de\u7dda\u3092\u653e\u51fa\u3059\u308b32P\u672b\u7aef\u6a19\u8b58\u30d7\u30e9\u30a4\u30de\u30fc\u3088\u308a\u3082\u30d7\u30ed\u30bb\u30b9\u304c\u6bd4\u8f03\u7684\u5b89\u5168\u306b\u306a\u308b\u305f\u3081\u300135S\u6a19\u8b58ddNTP\u304c\u5229\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u3053\u3061\u3089\u3088\u308a\u3001\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u8a73\u7d30\u306a\u8aac\u660e\u52d5\u753b\u3092\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12640\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/795316b92fc766b0181f6fef074f03fa.jpg\" alt=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\" width=\"768\" height=\"502\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/795316b92fc766b0181f6fef074f03fa.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/795316b92fc766b0181f6fef074f03fa-300x196.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/p>\n<p>\u3053\u306e\u624b\u6cd5\u304c1970\u5e74\u4ee3\u5f8c\u534a\u306b\u521d\u3081\u3066\u5c0e\u5165\u3055\u308c\u305f\u3068\u304d\u3001\u653e\u5c04\u6027\u672b\u7aef\u6a19\u8b58\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u4f7f\u7528\u3055\u308c\u3001\u5404\u53cd\u5fdc\u306f\u3001\u5404\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306b1\u3064\u305a\u3064\u30014\u3064\u306e\u500b\u5225\u306e\u30c1\u30e5\u30fc\u30d6\u3067\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3057\u305f\uff08\u305f\u3068\u3048\u3070\u3001\u300cA\u300d\u3068\u30e9\u30d9\u30eb\u3055\u308c\u305f\u30c1\u30e5\u30fc\u30d6\u306b\u306f\u30014\u3064\u3059\u3079\u3066\u306edNTP\uff08DNA\u9396\u4f38\u9577\u306e\u901a\u5e38\u306e\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\uff09\u3068ddATP\u304c\u6df7\u5728\u3057\u3066\u53cd\u5fdc\uff09\u3002<\/p>\n<p>\u6b21\u306b\u3001\u5404\u30c1\u30e5\u30fc\u30d6\u3054\u3068\u306e\u751f\u6210\u7269\u3092\u5927\u304d\u306a\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b9\u30e9\u30d6\u96fb\u6c17\u6cf3\u52d5\u30b2\u30eb\u4e0a\uff08\u4f8b\uff1a30 cm x 50 cm\uff09\u3067\u30b5\u30a4\u30ba\u3054\u3068\u306b\u5206\u96e2\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30b2\u30eb\u3092\u4e7e\u71e5\u3055\u305b\u3001\u30aa\u30fc\u30c8\u30e9\u30b8\u30aa\u30b0\u30e9\u30d5\u30a3\u30fc\u3067X\u7dda\u30d5\u30a3\u30eb\u30e0\u306b\u611f\u5149\u3055\u305b\u305f\u5f8c\u3001\u30e9\u30c0\u30fc\u72b6\u306e\u30d1\u30bf\u30fc\u30f3\u304b\u3089\u5869\u57fa\u914d\u5217\u3092\u8aad\u307f\u53d6\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_12641\" style=\"width: 478px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-12641\" class=\"size-full wp-image-12641\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/2b530e80c7d0de90885e285c5d798063.jpg\" alt=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\" width=\"468\" height=\"977\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/2b530e80c7d0de90885e285c5d798063.jpg 468w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/2b530e80c7d0de90885e285c5d798063-144x300.jpg 144w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><p id=\"caption-attachment-12641\" class=\"wp-caption-text\">Biotechniques. 1998 Nov;25(5):876-8, 880-2, 884. doi: 10.2144\/98255rr02.<\/p><\/div>\n<p>\u3053\u308c\u3089\u306e\u30d7\u30ed\u30bb\u30b9\u306f\u30de\u30cb\u30e5\u30a2\u30eb\u3067\u884c\u308f\u308c\u3001\u30aa\u30fc\u30c8\u30e9\u30b8\u30aa\u30b0\u30e9\u30e0\u3092\u8aad\u307f\u53d6\u308b\u305f\u3081\u306e\u86cd\u5149\u706f\u30dc\u30c3\u30af\u30b9\u3001\u5b9a\u898f\u3001\u305d\u3057\u3066\uff08\u5f53\u6642\u306f\u3088\u308a\u4fbf\u5229\u306a\u65b9\u6cd5\u3068\u3057\u3066\uff09\u4e00\u5ea6\u306b1\u30d9\u30fc\u30b9\u305a\u3064\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u306bG. G. A. A. T. T. C. C. A\u2026\u306e\u3088\u3046\u306b\u30014\u6587\u5b57\u3092\u5165\u529b\u3059\u308b\u88dc\u52a9\u6a5f\u80fd\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u6e96\u5099\u304b\u3089\u5869\u57fa\u914d\u5217\u306e\u8aad\u307f\u53d6\u308a\u307e\u3067\u7d041.5\u65e5\u9593\u304b\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u6b63\u78ba\u6027\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u518d\u5ea6\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u3059\u308b\u3053\u3068\u306f\u73cd\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n<h2>\u30b7\u30fc\u30b1\u30f3\u30b9\u6280\u8853\u306e\u4e3b\u8981\u306a\u5909\u9077<\/h2>\n<p>20\u5e74\u4ee5\u4e0a\u524d\u3088\u308a\u3001\u653e\u5c04\u6027\u7269\u8cea\u3067\u6a19\u8b58\u3055\u308c\u305f\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u304c\u86cd\u5149\u6a19\u8b58\u306e\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306b\u7f6e\u304d\u63db\u3048\u3089\u308c\u3001X\u7dda\u30d5\u30a3\u30eb\u30e0\u304b\u3089X\u7dda\u30d5\u30a3\u30eb\u30e0\u30ab\u30bb\u30c3\u30c8\u306e\u6697\u5ba4\u3067\u306e\u64cd\u4f5c\u306b\u7f6e\u304d\u63db\u308f\u308a\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u81ea\u52d5\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u304c\u767b\u5834\u3057\u3001\u8d70\u67fb\u578b\u30ec\u30fc\u30b6\u30fc\u3068\u9ad8\u5ea6\u306a\u5149\u5b66\u7cfb\u3092\u5099\u3048\u305f\u5149\u96fb\u5b50\u5897\u500d\u7ba1\u3092\u4f7f\u7528\u3057\u3066\u86cd\u5149\u8272\u7d20\u3092\u8aad\u307f\u53d6\u308a\u3001DNA\u5869\u57fa\u914d\u5217\u30c7\u30fc\u30bf\u3092\u76f4\u63a5\u81ea\u52d5\u51fa\u529b\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u3057\u304b\u3057\u3001\u5897\u611f\u7d19\u30fb\u30d5\u30a3\u30eb\u30e0\u30ab\u30bb\u30c3\u30c8\u3092-80\u2103\u306e\u51b7\u51cd\u5eab\u306b\u4e00\u6669\u7f6e\u304f\u5fc5\u8981\u304c\u3042\u308bX\u7dda\u30d5\u30a3\u30eb\u30e0\u30ab\u30bb\u30c3\u30c8\u3068\u3001\u73fe\u50cf\u85ac\u306e\u7dad\u6301\u3082\u4f34\u3046\u6697\u5ba4\u3067\u306e\u9762\u5012\u306a\u30d5\u30a3\u30eb\u30e0\u64cd\u4f5c\u304c\u4f34\u3046\u305f\u3081\u3001\u3088\u308a\u7c21\u4fbf\u306a\u86cd\u5149\u7269\u8cea\u3068\u5149\u5b66\u7cfb\u3067\u306e\u691c\u51fa\u3078\u306e\u5909\u9077\u304c\u30011986\u5e74\u306bApplied Biosystems\u2122 370A DNA Sequencer\u304c\u767b\u5834\u3057\u305f\u3053\u3068\u306b\u3088\u308a\u8d77\u3053\u308a\u3001\u3055\u3089\u306a\u308b\u5927\u304d\u306a\u5909\u9077\u306f\u30011995\u5e74\u306b\u767b\u5834\u3057\u305fApplied Biosystems\u2122 310 genetic analyzer\u306b\u3088\u308a\u8d77\u3053\u308a\u307e\u3057\u305f\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-12642\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/c8856789ec11ab8b1013037cef6929f9.jpg\" alt=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\" width=\"232\" height=\"218\" \/><\/p>\n<p>\u305d\u308c\u307e\u3067Applied Biosystems\u2122 370A DNA Sequencer\u306a\u3069\u3067\u4f7f\u7528\u3055\u308c\u3066\u3044\u305f\u4f7f\u7528\u3055\u308c\u3066\u3044\u305f\u96fb\u6c17\u6cf3\u52d5\u7528\u30b2\u30eb\u306e\u30ac\u30e9\u30b9\u30d7\u30ec\u30fc\u30c8\u306f\u3001\u76f8\u5f53\u306b\u30af\u30ea\u30fc\u30f3\u306a\u72b6\u614b\u3067\u6271\u308f\u308c\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u304c\u91cd\u5408\u3059\u308b2\u679a\u306e\u30ac\u30e9\u30b9\u306e\u9593\u9694\u306f\u975e\u5e38\u306b\u72ed\u304f\uff08\u4f8b\uff1a0.4 mm\uff09\u3001\u4e00\u7247\u306e\u307b\u3053\u308a\u304c\u5bb9\u6613\u306b\u6c17\u6ce1\u306e\u539f\u56e0\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u52a0\u3048\u3066\u3001\u30d5\u30ec\u30c3\u30b7\u30e5\u306a\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u6eb6\u6db2\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u6700\u9069\u306a\u7d50\u679c\u306b\u306f\u5fc5\u8981\u3067\u3042\u308b\u305f\u3081\u3001\u767a\u304c\u3093\u6027\u7269\u8cea\u3068\u3057\u3066\u7591\u308f\u308c\u308b\u7c89\u672b\u72b6\u306e\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u3092\u6271\u3046\u5fc5\u8981\u304c\u6709\u308a\u307e\u3057\u305f\u3002Applied Biosystems\u2122 310 Genetic Analyzer\u306f\u3001\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3059\u308b\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u578b\u306e\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3059\u3002<\/p>\n<h2>\u30b7\u30fc\u30b1\u30f3\u30b9\u6280\u8853\u306f\u30b2\u30ce\u30e0\u89e3\u6790\u3092\u6620\u3059\u93e1<\/h2>\n<p>Applied Biosystems\u2122310 Genetic Analyzer\u304c\u767b\u5834\u3057\u305f\u6570\u5e74\u5f8c\u306b\u306f\u300196\u672c\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3092\u6301\u3064Applied Biosystems\u2122 3700 DNA Analyzer\u304cHuman Genome Project\u306b\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e 3700 DNA Analyzer\u306b\u306f\u3001\u751f\u5316\u5b66\u30fb\u9ad8\u5206\u5b50\u5316\u5b66\u30fb\u304a\u3088\u3073\u6a5f\u68b0\u5de5\u5b66\uff0f\u5149\u5de5\u5b66\u306e\u9762\u3067\u306e\u6539\u826f\u304c\u65bd\u3055\u308c\u307e\u3057\u305f\u3002Dr. Elaine Mardis\u6c0f\uff08\u5f53\u6642\uff1aWashington University Genome Sequencing Center\u306eco-director\uff09\u306f\u30013700 DNA Analyzer\u306b\u3064\u3044\u3066\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\u3067\u6b21\u306e\u3088\u3046\u306b\u8ff0\u3079\u3066\u3044\u307e\u3059\uff1a\u300c\u3053\u306eHuman Genome Project\u306f\u3001\u3069\u3053\u3092\u898b\u3066\u3082\u3001\u3053\u308c\u3089\u306e\u6a5f\u5668\u304c\u306a\u3051\u308c\u3070\u3067\u304d\u306a\u304b\u3063\u305f\u3068\u601d\u3044\u307e\u3059\u3002\u300d<\/p>\n<p>\u3053\u308c\u3089\u306e\u6570\u5341\u5e74\u306b\u308f\u305f\u308b\u6280\u8853\u7684\u9032\u6b69\u306e\u7d50\u679c\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u54c1\u8cea\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3067\u3042\u308b\u3068\u3044\u3046\u6b63\u5f53\u306a\u8cc7\u683c\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306b\u4f7f\u7528\u3055\u308c\u308bDNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u5de5\u5b66\u306b\u3088\u308b\u6539\u826f\uff08\u7121\u6a5f\u7269\u8cea\u3067\u3042\u308b\u86cd\u5149\u8272\u7d20\u3067\u4fee\u98fe\u3055\u308c\u305f\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306f\u6bd4\u8f03\u7684\u5927\u304d\u306a\u5206\u5b50\u3068\u306a\u308a\u3001\u3053\u308c\u3089\u3092\u53ce\u3081\u308b\u305f\u3081\u306e\u300c\u30dd\u30b1\u30c3\u30c8\u300d\u3092\u4f5c\u308b\u305f\u3081\u306b\u5de5\u5b66\u7684\u306a\u6280\u8853\u304c\u304b\u306a\u308a\u5fc5\u8981\uff09\u3001\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u306a\u3069\u306ePOP\u30dd\u30ea\u30de\u30fc\u69cb\u6210\u6210\u5206\u306e\u5316\u5b66\u7684\u306a\u6539\u826f\u3001\u65b0\u3057\u3044\u86cd\u5149\u306b\u95a2\u9023\u3057\u305f\u86cd\u5149\u306e\u5fae\u5999\u306a\u5909\u5316\u3092\u611f\u77e5\u3059\u308b\u305f\u3081\u306e\u5149\u5b66\u7684\u6539\u826f\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3068\u30a8\u30e9\u30fc\u30e2\u30c7\u30ea\u30f3\u30b0\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u6539\u826f\u306b\u3088\u308a\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3001\u975e\u5e38\u306b\u9ad8\u3044\u7cbe\u5ea6\u3067\u6b63\u78ba\u306a\u7d50\u679c\u3092\u63d0\u4f9b\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u73fe\u5728\u8ca9\u58f2\u3055\u308c\u3066\u3044\u308b\u30b7\u30b9\u30c6\u30e0\u306e\u4e00\u3064\u3067\u3042\u308bApplied Biosystems\u2122 3500\u30b7\u30ea\u30fc\u30baGenetic Analyzer\u306b\u306f\u3001\u3088\u308a\u7c21\u5358\u306b\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u306b\u3055\u307e\u3056\u307e\u306a\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u304c\u7d44\u307f\u8fbc\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u9577\u5bff\u547d\u306a\u56fa\u4f53\u30ec\u30fc\u30b6\u30fc\u3001RFID\u30bf\u30b0\u306b\u3088\u308b\u6d88\u8017\u54c1\u306e\u4f7f\u7528\u72b6\u6cc1\u3068\u30ed\u30c3\u30c8\u756a\u53f7\u306e\u8ffd\u8de1\u3001\u5305\u88c5\u6e08\u307f\u306e\u30dd\u30ea\u30de\u30fc\u30d1\u30a6\u30c1\u3001\u30c7\u30fc\u30bf\u53ce\u96c6\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u307e\u3067\u3001\u3059\u3079\u3066\u304c\u4f7f\u3044\u3084\u3059\u3044\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-12643\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\" alt=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\" width=\"650\" height=\"599\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg 650w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd-300x276.jpg 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/p>\n<h2>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u6b63\u78ba\u6027<\/h2>\n<p>\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u5927\u5e45\u306b\u9032\u6b69\u3057\u3001\u304b\u3064\u30b7\u30b9\u30c6\u30e0\u304c\u9577\u5e74\u306b\u308f\u305f\u3063\u3066\u958b\u767a\u3055\u308c\u3066\u304d\u305f\u305f\u3081\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30a8\u30e9\u30fc\u30e2\u30c7\u30eb\u306f\u4e00\u822c\u7684\u306a\u30e2\u30c7\u30eb\u3068\u3057\u3066\u5e83\u304f\u666e\u53ca\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001Phred\u3068\u547c\u3070\u308c\u308b\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3088\u3063\u3066\u5b9a\u91cf\u5316\u3055\u308c\u3001Q=\u201310log10P\u3068\u3057\u3066\u5b9a\u7fa9\u3055\u308c\u307e\u3059\u3002Q\u306f\u54c1\u8cea\u306e\u30b9\u30b3\u30a2\u3001P\u306f\u30a8\u30e9\u30fc\u306e\u78ba\u7387\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30a8\u30e9\u30fc\u304c10\uff05\u306e\u5834\u5408\u3001Phred\u306b\u3088\u308b\u54c1\u8cea\u30b9\u30b3\u30a2\u306f10\u3067\u3042\u308b\u305f\u3081\u3001\u7cbe\u5ea6\u306f90\uff05\u306b\u306a\u308a\u307e\u3059\u3002Phred\u30b9\u30b3\u30a2\u304c20\u306e\u5834\u5408\u3001\u30a8\u30e9\u30fc\u306f1\uff05\u3001\u7cbe\u5ea6\u306f99\uff05\u3068\u306a\u308a\u3001Phred\u30b9\u30b3\u30a2\u304c30\u306e\u5834\u5408\u3001\u30a8\u30e9\u30fc\u306f0.1\uff05\u3001\u7cbe\u5ea6\u306f99.9\uff05\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u306e\u5168\u4f53\u7684\u306a\u7cbe\u5ea6\u306f\u304a\u304a\u3088\u305d99.95\uff05\u3001\u307e\u305f\u306f\u30a8\u30e9\u30fc0.05\uff05\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f2\u3064\u306e\u5074\u9762\uff08\u9ad8\u3044\u7cbe\u5ea6\u3068\u8aad\u307f\u53d6\u308a\u9577\uff1a800\uff5e1000 bp\uff09\u306b\u3088\u308a\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3057\u3066\u8a8d\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbRI\u6a19\u8b58\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u4ee3\u308f\u308a\u86cd\u5149\u6a19\u8b58\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u3001\u30ac\u30e9\u30b9\u677f\u306b\u4ee3\u308f\u308a\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3001\u3088\u308a\u5b89\u5168\u306b\u4f7f\u3044\u3084\u3059\u304f\u306a\u3063\u3066\u304d\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u81ea\u52d5DNA\u30b7\u30fc\u30b1\u30f3\u30b5\u3068\u3057\u3066\u767b\u5834\u3057\u305f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306f\u3001\u73fe\u5728\u3067\u3082\u3055\u307e\u3056\u307e\u306a\u9762\u3067\u6280\u8853\u7684\u9032\u6b69\u3092\u7d9a\u3051\u3066\u3044\u307e\u3059\u3002<br \/>\n\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3001\u305d\u306e\u9ad8\u3044\u7cbe\u5ea6\u3068\u30ed\u30f3\u30b0\u30ea\u30fc\u30c9\u306b\u3088\u308a\u3001DNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3057\u3066\u8a8d\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u6b21\u56de\u306e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u305d\u306e2\uff1a\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h2>\uff3b\u7121\u6599\u516c\u958b\u4e2d\uff3d\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3084\u30c7\u30fc\u30bf\u304b\u3089\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u3061\u3089\u306e\u30ac\u30a4\u30c9\u306b\u3082\u8a73\u3057\u3044\u8a18\u8f09\u304c\u3054\u3056\u3044\u307e\u3059\u3002\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002 DNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u304c\u958b\u767a\u30fb\u767a\u8868\u3055\u308c\u3066\u304b\u308940\u5e74\u4ee5\u4e0a\u7d4c\u904e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3044\u307e\u3060\u306b\u591a\u304f\u306e\u7814\u7a76\u5206\u91ce\u3067<\/p>\n","protected":false},"author":975,"featured_media":12643,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[183],"division":[],"class_list":["post-12636","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-sanger-seq","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e\" \/>\n<meta property=\"og:description\" content=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002 DNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u304c\u958b\u767a\u30fb\u767a\u8868\u3055\u308c\u3066\u304b\u308940\u5e74\u4ee5\u4e0a\u7d4c\u904e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3044\u307e\u3060\u306b\u591a\u304f\u306e\u7814\u7a76\u5206\u91ce\u3067\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-29T02:33:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T07:20:16+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"599\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e\",\"datePublished\":\"2022-09-29T02:33:46+00:00\",\"dateModified\":\"2024-09-18T07:20:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/\"},\"wordCount\":133,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"keywords\":[\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/\",\"name\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"datePublished\":\"2022-09-29T02:33:46+00:00\",\"dateModified\":\"2024-09-18T07:20:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"width\":650,\"height\":599,\"caption\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e","og_description":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002 DNA\u306e\u5869\u57fa\u914d\u5217\u6c7a\u5b9a\u6cd5\u304c\u958b\u767a\u30fb\u767a\u8868\u3055\u308c\u3066\u304b\u308940\u5e74\u4ee5\u4e0a\u7d4c\u904e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306f\u3044\u307e\u3060\u306b\u591a\u304f\u306e\u7814\u7a76\u5206\u91ce\u3067","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-09-29T02:33:46+00:00","article_modified_time":"2024-09-18T07:20:16+00:00","og_image":[{"width":650,"height":599,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e","datePublished":"2022-09-29T02:33:46+00:00","dateModified":"2024-09-18T07:20:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/"},"wordCount":133,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","keywords":["\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/","name":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","datePublished":"2022-09-29T02:33:46+00:00","dateModified":"2024-09-18T07:20:16+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","width":650,"height":599,"caption":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg",650,599,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24647,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url_meta":{"origin":12636,"position":0},"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","author":"LatB Staff","date":"2026\u5e742\u67089\u65e5","format":false,"excerpt":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":12636,"position":1},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24953,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-26011\/","url_meta":{"origin":12636,"position":2},"title":"\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u8abf\u88fd\u306e\u81ea\u52d5\u5316\u3067NGS\u306e\u53ef\u80fd\u6027\u3092\u5e83\u3052\u308b\u2015Ion Chef\u30b7\u30b9\u30c6\u30e0\u304c\u5909\u3048\u308b\u7814\u7a76\u5ba4\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc","author":"LatB Staff","date":"2026\u5e744\u670810\u65e5","format":false,"excerpt":"\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\u304c\u3001NGS\u306e\u65b0\u3057\u3044\u6a19\u6e96\u3092\u3064\u304f\u308b\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\uff08NGS\uff09\u304c\u65e5\u5e38\u7684\u306a\u7814\u7a76\u30c4\u30fc\u30eb\u3068\u306a\u3063\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/ngs-gene-expression-csd-ts-ion-26011_eyecatch.jpeg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":12636,"position":3},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":12636,"position":4},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":12636,"position":5},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12636"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12636\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12643"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12636"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12636"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12636"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}