{"id":12678,"date":"2022-10-18T08:55:51","date_gmt":"2022-10-17T23:55:51","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=12678"},"modified":"2025-06-12T19:54:07","modified_gmt":"2025-06-12T10:54:07","slug":"ce_basic_dna_gsd_ts_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/","title":{"rendered":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068"},"content":{"rendered":"<p>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u30022\u56de\u76ee\u3067\u3042\u308b\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5869\u57fa\u914d\u5217\u3092\u8aad\u307e\u306a\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\u4f55\u304b\u3001\u3067\u3059\u3002\u4f75\u305b\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u5b9f\u65bd\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p><b>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fb1\u56de\u76ee\u306e\u8a18\u4e8b\u3092\u8aad\u3093\u3067\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u5206\u89e3\u80fd\u306b\u8208\u5473\u3092\u6301\u3063\u305f\u65b9<br \/>\n\u30fb\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u30d0\u30f3\u30c9\u5206\u89e3\u80fd\u306b\u9650\u754c\u3092\u611f\u3058\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u3044\u3064\u3067\u3082\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u89e6\u3063\u3066\u3044\u305f\u3044\u65b9<\/p>\n<h2>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\uff1dDNA\u306e\u9577\u3055\u3092\u6e2c\u5b9a<\/h2>\n<p>1\u56de\u76ee\u306e\u8a18\u4e8b\u3067\u306f\u3001\u30b8\u30c7\u30aa\u30ad\u30b7\u6cd5\u306b\u3088\u308aDNA\u9396\u306e\u4f38\u9577\u3092\u505c\u6b62\u3055\u305b\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\uff08CE\uff09\u3067\u96fb\u6c17\u6cf3\u52d5\u3059\u308b\u3053\u3068\u3067\u3001DNA\u306e1\u5869\u57fa\u3054\u3068\u306e\u5909\u5316\u3092\u5206\u96e2\u30fb\u533a\u5225\u3059\u308b\u65b9\u6cd5\u3092\u8aac\u660e\u3057\u307e\u3057\u305f\u3002<br \/>\n\u4eca\u56de\u306f\u3001\u5869\u57fa\u914d\u5217\u60c5\u5831\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u9577\u306e\u5dee\u7570\u3092\u5229\u7528\u3059\u308b\u306e\u3067\u306f\u306a\u304f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30a4\u30ba\u306eDNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u9577\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\uff08CE\uff09\u3092\u4f7f\u7528\u3057\u3066\u6e2c\u5b9a\u3059\u308b\u3001\u7570\u306a\u308b\u30bf\u30a4\u30d7\u306eDNA\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-12682\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\" alt=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\" width=\"599\" height=\"304\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg 599w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5-300x152.jpg 300w\" sizes=\"auto, (max-width: 599px) 100vw, 599px\" \/><\/p>\n<p>\u5927\u5b66\u306e\u751f\u7269\u5b66\u306e\u8b1b\u7fa9\u3067\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308aDNA\u5206\u5b50\u3092\u9577\u3055\u306b\u3088\u308a\u5206\u96e2\u3001\u30a8\u30c1\u30b8\u30a6\u30e0\u30d6\u30ed\u30de\u30a4\u30c9\u3067\u30b2\u30eb\u3092\u67d3\u8272\u3057\u3001UV\u30c8\u30e9\u30f3\u30b9\u30a4\u30eb\u30df\u30cd\u30fc\u30bf\u30fc\u4e0a\u3067\u5199\u771f\u3092\u64ae\u5f71\u3059\u308b\u65b9\u6cd5\u3092\u6559\u308f\u3063\u305f\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u304b\u3068\u601d\u3044\u307e\u3059\uff08\u6700\u8fd1\u3067\u306f\u9ad8\u6821\u306e\u6388\u696d\u3067\u3082\u6271\u308f\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u304d\u307e\u3057\u305f\uff09\u3002\u5206\u96e2\u3055\u308c\u305fDNA\u65ad\u7247\u306e\u76f8\u5bfe\u7684\u306a\u30b5\u30a4\u30ba\u306f\u3001\u65e2\u77e5\u306e\u30b5\u30a4\u30ba\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3067\u3042\u308b\u300c\u30e9\u30c0\u30fc\u300d\u3068\u306e\u6bd4\u8f03\u306b\u3088\u308a\u6c7a\u5b9a\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5206\u96e2\u304b\u3089\u30b5\u30a4\u30ba\u306e\u6c7a\u5b9a\u307e\u3067\u306e\u5168\u30d7\u30ed\u30bb\u30b9\u304c\u5b8c\u5168\u306b\u81ea\u52d5\u5316\u3055\u308c\u308b\u306a\u3089\u3070\u30fb\u30fb\u30fb<br \/>\n\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u88c5\u7f6e\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u9069\u5207\u306a\u8272\u7d20\u3067\u6a19\u8b58\u3055\u308c\u305fDNA\u65ad\u7247\u306e\u30b5\u30a4\u30ba\u3092\u30b5\u30a4\u30ba\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u6bd4\u8f03\u3059\u308b\u3053\u3068\u3067\u8fc5\u901f\u306b\u6c7a\u5b9a\u3067\u304d\u307e\u3059\u3002\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u9175\u7d20\u304c\u53d6\u308a\u8fbc\u3080\u30d7\u30e9\u30a4\u30de\u30fc\u30d9\u30fc\u30b9\u306e\u65b9\u6cd5\u3067\u306f\u86cd\u5149\u8272\u7d20\u3067\u6a19\u8b58\u3055\u308c\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u307e\u305f\u306f\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u304c\u4f7f\u7528\u3055\u308c\u3001\u5f97\u3089\u308c\u305f\u751f\u6210\u7269\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3057\u30b5\u30a4\u30ba\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u306e\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306f\u3001\u304b\u3064\u3066\u653e\u5c04\u7dda\u3068X\u7dda\u30d5\u30a3\u30eb\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u305f\u4f1d\u7d71\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u7531\u6765\u3057\u3066\u3044\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30de\u30a4\u30af\u30ed\u30b5\u30c6\u30e9\u30a4\u30c8\u30de\u30fc\u30ab\u30fc\u304c\u9023\u9396\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u308b\u524d\u306f\u3001\u5236\u9650\u9175\u7d20\u65ad\u7247\u9577\u591a\u578b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/restriction-fragment-length-polymorphism-rflp-analysis.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">RFLP: Restriction Fragment Length Polymorphism<\/a>\u3068\u547c\u3070\u308c\u308b\u65b9\u6cd5\u304c1980\u5e74\u3088\u308a\u5b58\u5728\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u4eca\u3067\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u3001RFLP\u89e3\u6790\u306f\u7c21\u5358\u306b\u5b9f\u65bd\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u30de\u30a4\u30af\u30ed\u30b5\u30c6\u30e9\u30a4\u30c8\u89e3\u6790\u3082\u591a\u304f\u306e\u65b9\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u308b\u4e3b\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3059\u3002\u30de\u30a4\u30af\u30ed\u30b5\u30c6\u30e9\u30a4\u30c8\uff08\u30b7\u30e7\u30fc\u30c8\u30bf\u30f3\u30c7\u30e0\u30ea\u30d4\u30fc\u30c8\u914d\u5217\u3001STR: Short Tandem Repeat\u3068\u3082\u547c\u3070\u308c\u307e\u3059\uff09\u3068\u306f2\u301c7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u306e\u7e70\u308a\u8fd4\u3057\u5358\u4f4d\u3067\u3059\u304c\u3001\u5404\u5bfe\u7acb\u907a\u4f1d\u5b50\u3067\u7e70\u308a\u8fd4\u3057\u306e\u6570\u304c\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30de\u30a4\u30af\u30ed\u30b5\u30c6\u30e9\u30a4\u30c8\u89e3\u6790\u306f\u3001\u96c6\u56e3\u907a\u4f1d\u5b66\u306b\u52a0\u3048\u3066\u3001\u9023\u9396\u30de\u30c3\u30d4\u30f3\u30b0\u3001\u89aa\u5b50\u95a2\u4fc2\u5206\u6790\u3001\u304a\u3088\u3073\u8fb2\u696d\u30fb\u80b2\u7a2e\u5206\u91ce\u306a\u3069\u306b\u5e45\u5e83\u304f\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12685\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/cbf5b9f60da99bf791c0aa12a770f429.png\" alt=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\" width=\"895\" height=\"309\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/cbf5b9f60da99bf791c0aa12a770f429.png 895w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/cbf5b9f60da99bf791c0aa12a770f429-300x104.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/cbf5b9f60da99bf791c0aa12a770f429-768x265.png 768w\" sizes=\"auto, (max-width: 895px) 100vw, 895px\" \/><\/p>\n<p>\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u3082\u4e3b\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3059\u3002Applied Biosystems\u2122 SNaPshotTM Multiplex Kit\u306f\u3001\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3067\u306e\u4e00\u5869\u57fa\u306e\u4f38\u9577\u3092\u5229\u7528\u3057\u3066\u3001\u6700\u592710\u500b\u306e\u5909\u7570\u3092\u540c\u6642\u306b\u6c7a\u5b9a\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u5897\u5e45\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u9577\u591a\u578b\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/amplified-fragment-length-polymorphism-aflp-analysis.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">AFLP\uff1aAmplification Fragment Length Polymorphisms<\/a>\uff09\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/bacterial-artificial-chromosome-bac-fingerprinting.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">BAC\u30d5\u30a3\u30f3\u30ac\u30fc\u30d7\u30ea\u30f3\u30c8<\/a>\u3001\u30bf\u30a4\u30ea\u30f3\u30b0\uff08\u30a2\u30b0\u30ea\u30d0\u30a4\u30aa\u3067\u5229\u7528\uff09\u3001\u3055\u3089\u306b\u306f\u4e00\u672c\u9396\u9ad8\u6b21\u69cb\u9020\u591a\u578b\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/single-strand-conformation-polymorphism-sscp.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">SSCP\uff1aSingle-Strand Conformational Polymorphism<\/a>\uff09\u3068\u3044\u3063\u305f\u4ed6\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3059\u3079\u3066\u3001\u5236\u9650\u9175\u7d20\u8a8d\u8b58\u90e8\u4f4d\u306e\u5869\u57fa\u914d\u5217\u306e\u5909\u5316\u306e\u6709\u7121\u3001\u307e\u305f\u306fPCR\u7528\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u90e8\u4f4d\u9593\u306e\u914d\u5217\u5909\u7570\u306b\u57fa\u3065\u3044\u3066\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u5909\u7570\u306e\u6709\u7121\u3092\u8abf\u3079\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u65b9\u6cd5\u3067\u306f\u3001\u8abf\u3079\u305f\u3044\u500b\u3005\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u5869\u57fa\u914d\u5217\u3092\u4e8b\u524d\u306b\u77e5\u3089\u306a\u304f\u3066\u3082\u3001\u907a\u4f1d\u7684\u5909\u7570\u306e\u6709\u7121\u3092\u8abf\u3079\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30d8\u30c6\u30ed\u63a5\u5408\u6027\u6d88\u5931\uff08LOH\uff1aloss of heterozygosity\uff09\u3001\u7570\u6570\u6027\u3001\u307e\u305f\u306f\u5927\u304d\u306a\u67d3\u8272\u4f53\u6b20\u5931\u306a\u3069\u306e\u6b20\u5931\u5909\u7570\u3092\u8abf\u3079\u308b\u305f\u3081\u306b\u3001\u8907\u6570\u30b5\u30f3\u30d7\u30eb\u306e\u86cd\u5149\u30d4\u30fc\u30af\u306e\u9ad8\u3055\u3092\u6e2c\u5b9a\u3057\u3066\u6b20\u5931\u30a4\u30d9\u30f3\u30c8\u3092\u691c\u51fa\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/quantitative-fluorescence-pcr.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">QF-PCR<\/a>\u6cd5\uff08Quantitative Fluoresence\uff09\u3082\u958b\u767a\u3055\u308c\u307e\u3057\u305f\uff08\u534a\u6570\u4f53\u306e\u6027\u8cea\u306b\u3088\u308a\u3001LOH\u306e\u9818\u57df\u306f\u901a\u5e38\u306e2\u500d\u4f53\u9818\u57df\u3068\u6bd4\u8f03\u3057\u3066\u534a\u5206\u306e\u76f8\u5bfe\u86cd\u5149\u5f37\u5ea6\u3092\u6301\u3061\u307e\u3059\u3002\uff09<\/p>\n<p>\u86cd\u5149\u6a19\u8b58\u3055\u308c\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u307e\u305f\u306f\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3092\u7528\u3044\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u7528\u3044\u305fDNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u30b5\u30a4\u30ba\u5206\u6790\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u9069\u7528\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306e\u5206\u89e3\u80fd\u306b\u3088\u308a\u30011\u3064\u306e\u86cd\u5149\u8272\u7d20\u3067\u8907\u6570\u306e\u30de\u30fc\u30ab\u30fc\u3092\u4e00\u5ea6\u306b\u691c\u51fa\u3067\u304d\u307e\u3059\u3002\u306a\u304a\u3001\u4ed6\u306e\u86cd\u5149\u8272\u7d20\u3092\u4f75\u7528\u3059\u308b\u3053\u3068\u3067\u8907\u6570\u306e\u30b5\u30f3\u30d7\u30eb\u3067\u3082\u540c\u6642\u306b\u691c\u51fa\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u306e\u305f\u3081\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/h2>\n<p>Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/technical-reference-library\/capillary-electrophoresis-software-support-center\/fragment-analysis-software-support.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">GeneMapper\u2122\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u88c5\u7f6e\u306eData Collection\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u3063\u3066\u51fa\u529b\u3055\u308c\u305f.fsa\u30d5\u30a1\u30a4\u30eb\u3092\u8aad\u307f\u8fbc\u307f\u3001\u81ea\u52d5\u3067\u30d4\u30fc\u30af\u3092\u691c\u51fa\u3057\u3001\u30b5\u30a4\u30ba\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u60c5\u5831\u304b\u3089\u691c\u51fa\u3055\u308c\u305f\u30d4\u30fc\u30af\u306e\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u30b5\u30a4\u30ba\u60c5\u5831\u3092\u4ed8\u4e0e\u3057\u307e\u3059\u3002\u30a2\u30c3\u30bb\u30a4\u306b\u5fdc\u3058\u3066\u3001\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u30b8\u30a7\u30ce\u30bf\u30a4\u30d7\u3092\u5224\u5b9a\u3057\u3001\u305d\u306e\u6b63\u78ba\u6027\u3092\u8868\u3059\u5024\u3092\u4ed8\u4e0e\u3057\u305f\u308a\u3001\u5b9a\u91cf\u7684\u306a\u86cd\u5149\u6e2c\u5b9a\u306e\u305f\u3081\u306b\u76f8\u5bfe\u7684\u306a\u30d4\u30fc\u30af\u306e\u9ad8\u3055\u3092\u6c7a\u5b9a\u3057\u305f\u308a\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12687\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/5e4896966c9944fcf00890f4502605bf.png\" alt=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\" width=\"919\" height=\"361\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/5e4896966c9944fcf00890f4502605bf.png 919w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/5e4896966c9944fcf00890f4502605bf-300x118.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/5e4896966c9944fcf00890f4502605bf-768x302.png 768w\" sizes=\"auto, (max-width: 919px) 100vw, 919px\" \/><\/p>\n<p>\u3055\u3089\u306b\u3001FDA\u306e\u898f\u5247\u3067\u3042\u308b21 CFR Part 11\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3059\u88dc\u52a9\u3068\u306a\u308b\u30bb\u30ad\u30e5\u30ea\u30c6\u30a3\u6a5f\u80fd\u3068\u76e3\u67fb\u6a5f\u80fd\u3001\u304a\u3088\u3073\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u53ef\u80fd\u306a\u30ec\u30dd\u30fc\u30c8\u4f5c\u6210\u6a5f\u80fd\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fb\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\u3001DNA\u65ad\u7247\u306e\u9577\u3055\u3092\u6e2c\u5b9a\u3059\u308b\u89e3\u6790\u3067\u3059\u3002<br \/>\n\u30fb\u86cd\u5149\u6a19\u8b58\u3055\u308c\u305f\u30d7\u30e9\u30a4\u30de\u30fc\u3084\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u9ad8\u3044\u89e3\u50cf\u5ea6\u3092\u6301\u3064\u96fb\u6c17\u6cf3\u52d5\u304c\u81ea\u52d5\u3067\u5b9f\u65bd\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u306e\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u53ef\u80fd\u3068\u306a\u3063\u3066\u304d\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u7528\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u308a\u3001\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u30b5\u30a4\u30ba\u306e\u6c7a\u5b9a\u3084\u30b8\u30a7\u30ce\u30bf\u30a4\u30d4\u30f3\u30b0\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<p><b>\u95a2\u9023\u60c5\u5831<\/b><br \/>\n1 \u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8 :\u3000<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/fragment-analysis\/fragment-analysis-fundamentals.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/a><br \/>\n2 \u30ab\u30bf\u30ed\u30b0 :\u3000<a href=\"http:\/\/assets.thermofisher.com\/TFS-Assets\/GSD\/brochures\/dna-fragment-analysis-brochure-ja.pdf\" target=\"_blank\" rel=\"noopener\"> \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790<\/a><\/p>\n<h2>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u30e6\u30fc\u30b6\u30fc\u30ac\u30a4\u30c9\uff08\u65e5\u672c\u8a9e\u7248\uff09<\/h2>\n<p>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u306e\u57fa\u790e\u304b\u3089\u3001\u5b9f\u9a13\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306e\u30b3\u30c4\u3084\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u307e\u3067\u69d8\u3005\u306a\u30b3\u30f3\u30c6\u30f3\u30c4\u3092\u30ab\u30d0\u30fc\u3057\u3066\u3044\u308b\u30e6\u30fc\u30b6\u30ac\u30a4\u30c9\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/fragment-analysis-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u30022\u56de\u76ee\u3067\u3042\u308b\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5869\u57fa\u914d\u5217\u3092\u8aad\u307e\u306a\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\u4f55\u304b\u3001\u3067\u3059\u3002\u4f75\u305b\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u30d5\u30e9\u30b0<\/p>\n","protected":false},"author":975,"featured_media":12682,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[220],"division":[],"class_list":{"0":"post-12678","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-fragment-analysis","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068\" \/>\n<meta property=\"og:description\" content=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u30022\u56de\u76ee\u3067\u3042\u308b\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5869\u57fa\u914d\u5217\u3092\u8aad\u307e\u306a\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\u4f55\u304b\u3001\u3067\u3059\u3002\u4f75\u305b\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u30d5\u30e9\u30b0\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-10-17T23:55:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-12T10:54:07+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"599\" \/>\n\t<meta property=\"og:image:height\" content=\"304\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068\",\"datePublished\":\"2022-10-17T23:55:51+00:00\",\"dateModified\":\"2025-06-12T10:54:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/\"},\"wordCount\":59,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\",\"keywords\":[\"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/\",\"name\":\"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\",\"datePublished\":\"2022-10-17T23:55:51+00:00\",\"dateModified\":\"2025-06-12T10:54:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/29d3bc99193cb0b837fb8cc53f050ae5.jpg\",\"width\":599,\"height\":304,\"caption\":\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068","og_description":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3064\u3044\u3066\u30016\u56de\u306b\u5206\u3051\u3066\u57fa\u790e\u7684\u306a\u5185\u5bb9\u3092\u30e1\u30a4\u30f3\u306b\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u30022\u56de\u76ee\u3067\u3042\u308b\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5869\u57fa\u914d\u5217\u3092\u8aad\u307e\u306a\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3042\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3068\u306f\u4f55\u304b\u3001\u3067\u3059\u3002\u4f75\u305b\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u30d5\u30e9\u30b0","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-10-17T23:55:51+00:00","article_modified_time":"2025-06-12T10:54:07+00:00","og_image":[{"width":599,"height":304,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068","datePublished":"2022-10-17T23:55:51+00:00","dateModified":"2025-06-12T10:54:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/"},"wordCount":59,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","keywords":["\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/","name":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","datePublished":"2022-10-17T23:55:51+00:00","dateModified":"2025-06-12T10:54:07+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","width":599,"height":304,"caption":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790\u3001\u305d\u308c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u3067\u304d\u308b\u3082\u3046\u4e00\u3064\u306e\u3053\u3068"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":220,"label":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg",599,304,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":220,"name":"\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u89e3\u6790","slug":"fragment-analysis","term_group":0,"term_taxonomy_id":220,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":12678,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":12678,"position":1},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":12678,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":12678,"position":3},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":12678,"position":4},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":12678,"position":5},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/29d3bc99193cb0b837fb8cc53f050ae5.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=12678"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/12678\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12682"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=12678"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=12678"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=12678"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=12678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}