{"id":13036,"date":"2022-12-05T10:32:19","date_gmt":"2022-12-05T01:32:19","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13036"},"modified":"2026-02-18T18:19:34","modified_gmt":"2026-02-18T09:19:34","slug":"workshop_attune_flowcytometer_bid_ts_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f"},"content":{"rendered":"<p>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u89e3\u6790\u306e\u305f\u3081\u306b\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u969b\u306b\u826f\u304f\u5b9f\u65bd\u3055\u308c\u308b\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u3002\u540c\u3058\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306eArea(\u3082\u3057\u304f\u306fWidth)\u3068Height\u3067\u30c9\u30c3\u30c8\u30d7\u30ed\u30c3\u30c8\u3092\u5c55\u958b\u3059\u308b\u4e8b\u3067\u3001\u8907\u6570\u500b\u306e\u7d30\u80de\u304c\u56fa\u307e\u3063\u305f\u30d7\u30ed\u30c3\u30c8\uff08\u30c0\u30d6\u30ec\u30c3\u30c8\u3001\u30c8\u30ea\u30d7\u30ec\u30c3\u30c8\uff09\u3068\u5358\u96e2\u7d30\u80de\u7fa4\uff08\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\uff09\u3092\u533a\u5225\u3057\u3066\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u4e8b\u304c\u3067\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u7406\u5c48\u306f\u5206\u304b\u3063\u3066\u3044\u3066\u3082\u672c\u5f53\u306b\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u306e\u30d7\u30ed\u30c3\u30c8\u306f\u5358\u96e2\u3055\u308c\u305f\u7d30\u80de\u3067\u30c0\u30d6\u30ec\u30c3\u30c8\u306e\u7d30\u80de\u7fa4\u306f\u8907\u6570\u306e\u7d30\u80de\u304c\u304f\u3063\u3064\u3044\u3066\u3044\u308b\u306e\u304b\u306b\u95a2\u3057\u3066\u306f\u3001\u201c\u307b\u3093\u307e\u304b\u3044\u306a\uff1f\u201d\u3068\u3044\u3046\u7591\u554f\u304c\u4ed8\u304d\u307e\u3068\u3044\u3001\u5b9f\u969b\u306b\u898b\u3066\u307f\u306a\u3044\u3068\u4fe1\u3058\u3089\u308c\u306a\u3044\u3068\u3044\u3046\u65b9\u3082\u591a\u3044\u304b\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u305d\u3053\u3067\u6e2c\u5b9a\u3057\u305f\u7d30\u80de\u306e\u5199\u771f\u3092\u64ae\u5f71\u3057\u306a\u304c\u3089\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u304c\u3067\u304d\u308b\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fc\u3001Invitrogen\u2122 Attune\u2122 CytPix\u2122 Flow Cytometer\u3092\u4f7f\u3044\u3001\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u3068\u30c0\u30d6\u30ec\u30c3\u30c8\u306e\u30d7\u30ed\u30c3\u30c8\u306e\u7d30\u80de\u305f\u3061\u304c\u8a00\u308f\u308c\u3066\u3044\u308b\u901a\u308a\u306e\u96c6\u56e3\u306a\u306e\u304b\u3001\u5b9f\u969b\u306e\u59ff\u3092\u5199\u771f\u3067\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\uff01<\/p>\n<p><b>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fb\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u30e6\u30fc\u30b6\u30fc<br \/>\n\u30fb\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u521d\u5fc3\u8005<br \/>\n\u30fb\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u539f\u7406\u3092\u5b66\u3073\u305f\u3044\u65b9<br \/>\n\u30fb\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u7d30\u80de\u304c\u7406\u5c48\u901a\u308a\u306e\u59ff\u304b\u6c17\u306b\u306a\u3063\u3066\u3044\u305f\u65b9<\/p>\n<h2>\u6750\u6599\u3068\u6e2c\u5b9a\u65b9\u6cd5<\/h2>\n<p>\u30fb\u7d30\u80de<br \/>\nJurkat\u7d30\u80de<br \/>\n\u30fb\u6e2c\u5b9a\u88c5\u7f6e<br \/>\nAttune CytPix Flow Cytometer\u3000(\u88fd\u54c1\u756a\u53f7A48652)<br \/>\n\u30fb\u624b\u9806<br \/>\n\u2460 EtOH\u3067\u56fa\u5b9a\u3057\u305fJurkat\u7d30\u80de\u30921.0\u00d7106 cells\/mL\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2\u3092200 \u00b5L\u7528\u610f<br \/>\n\u2461 Attune CytPix Flow Cytometer\u306e\u6e2c\u5b9a\u901f\u5ea6\u3092100 \u00b5L\/min\u306b\u8a2d\u5b9a\u3057100 \u00b5L\u306e\u7d30\u80de\u6eb6\u6db2\u3092\u6e2c\u5b9a<br \/>\n\u2462 Attune CytPix Flow Cytometer\u4ed8\u5c5e\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u3068\u64ae\u5f71\u3057\u305f\u7d30\u80de\u306e\u5199\u771f\u3092\u78ba\u8a8d<\/p>\n<h2>\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306e\u65b9\u6cd5<\/h2>\n<p>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u306f\u3001\u6d41\u308c\u3066\u304d\u305f\u7c92\u5b50\uff08\u7d30\u80de\uff09\u304c\u30ec\u30fc\u30b6\u30fc\u3092\u901a\u904e\u3057\u3066\u5f97\u3089\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u3092\u691c\u51fa\u5668\u3067\u30d1\u30eb\u30b9\u751f\u6210\u3057\u3001\u305d\u308c\u304c\u7d50\u679c\u3068\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3055\u308c\u3066\u3044\u304d\u307e\u3059\u3002\u751f\u6210\u3055\u308c\u308b\u30d1\u30eb\u30b9\u3092X\u8ef8\u306b\u6642\u9593\u3001Y\u8ef8\u306b\u5f97\u3089\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3068\u3057\u3066\u63cf\u304f\u3068\u3001Width(W)\uff1a\u7c92\u5b50\u304c\u30ec\u30fc\u30b6\u30fc\u3092\u901a\u904e\u3059\u308b\u306e\u306b\u304b\u304b\u308b\u6642\u9593\u3001Height(H)\uff1a\u30d1\u30eb\u30b9\u306e\u6700\u5927\u5024\u3001Area(A)\uff1a\u30d1\u30eb\u30b9\u306e\u9762\u7a4d\u3068\u306a\u308a\u56f3 1\u306e\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-1.jpg\" alt=\"\" width=\"524\" height=\"399\" class=\"aligncenter size-full wp-image-13044\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-1.jpg 874w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-1-300x228.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-1-768x584.jpg 768w\" sizes=\"auto, (max-width: 524px) 100vw, 524px\" \/><\/p>\n<p style=\"text-align: center\"><b>\u56f31<\/b><b>. <\/b><b>\u691c\u51fa\u5668\u3067\u751f\u6210\u3055\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u30d1\u30eb\u30b9<\/b><\/p>\n<p>\u3067\u306f\u3001\u5927\u304d\u3055\u304c\u7570\u306a\u308b\u7d30\u80de\u3084\u30c0\u30d6\u30ec\u30c3\u30c8\u304c\u30ec\u30fc\u30b6\u30fc\u3092\u901a\u904e\u3059\u308b\u969b\u306b\u3069\u306e\u3088\u3046\u306a\u30d1\u30eb\u30b9\u5f62\u6210\u3092\u3059\u308b\u3067\u3057\u3087\u3046\u304b\u3002\u30a2\u30cb\u30e1\u30fc\u30b7\u30e7\u30f3\u3067\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3059\u3002<\/p>\n<p style=\"text-align: center\"><b>\u901a\u5e38\u306e\u30b7\u30f3\u30b0\u30eb\u7d30\u80de<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13040\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/ea380900f8c1a71cc99c6c90f3034c41.gif\" alt=\"\" width=\"853\" height=\"480\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center\"><b>\u901a\u5e38\u306e\u7d30\u80de\u3088\u308a\u3082\u30b5\u30a4\u30ba\u304c<\/b><b>2<\/b><b>\u500d\u5927\u304d\u3044\u7d30\u80de<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13042\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/40efb74dcf6c3d8abd223f3994d1eb9b.gif\" alt=\"\" width=\"853\" height=\"480\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center\"><b>\u30c0\u30d6\u30ec\u30c3\u30c8<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13041\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/9bb2004ede5d35ca5fa8cc6b004e4704.gif\" alt=\"\" width=\"853\" height=\"480\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>\u3053\u308c\u3089\u3092\u307e\u3068\u3081\u305f\u3082\u306e\u3068\u3001\u305d\u306e\u7d50\u679c\u3092X\u8ef8\uff1aArea\u3001Y\u8ef8\uff1aHeight\u3067\u30d7\u30ed\u30c3\u30c8\u3057\u305f\u30c9\u30c3\u30c8\u30d7\u30ed\u30c3\u30c8\u306e\u56f3\u304c\u6b21\u306e\u56f3 2\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13037\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-2.jpg\" alt=\"\" width=\"1168\" height=\"953\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-2.jpg 1168w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-2-300x245.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-2-1024x836.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-2-768x627.jpg 768w\" sizes=\"auto, (max-width: 1168px) 100vw, 1168px\" \/><\/p>\n<p style=\"text-align: center\"><b>\u56f32<\/b><b>. <\/b><b>\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u3068\u30c0\u30d6\u30ec\u30c3\u30c8\u306e\u30d7\u30ed\u30c3\u30c8<\/b><\/p>\n<p>\u203b\u3053\u3061\u3089\u306e\u56f3\u3067\u306fFSC-A\u3001FSC-H\u3067\u30d7\u30ed\u30c3\u30c8\u3057\u3066\u3044\u307e\u3059\u304c\u3001SSC\u3084\u86cd\u5149\u3092\u7528\u3044\u3066\u3082\u540c\u69d8\u3067\u3059\u3002<\/p>\n<p>\u7d30\u80de\u304c\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u3067\u3042\u308c\u3070\u3001Area\u3068Height\u3067\u4e00\u6b21\u95a2\u6570\u7684\u306a\u95a2\u4fc2\u3092\u793a\u3059\u6955\u5186\u3067\u56f2\u3063\u305f\u9818\u57df\u306b\u5927\u304d\u3055\u306b\u5fdc\u3058\u3066\u30d7\u30ed\u30c3\u30c8\u3055\u308c\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n<p>\u3057\u304b\u3057\u3001\u7d30\u80de\u540c\u58eb\u304c\u304f\u3063\u4ed8\u3044\u3066\u3044\u308b\u3044\u308f\u3086\u308b\u30c0\u30d6\u30ec\u30c3\u30c8\u3084\u30c8\u30ea\u30d7\u30ec\u30c3\u30c8\u3068\u3044\u3063\u305f\u7d30\u80de\u306f\u3001Height\u306e\u5024\u3068\u6bd4\u8f03\u3057\u3066Area\u306f\u5c0f\u3055\u3044\u5024\u3068\u3057\u3066\u51fa\u308b\u305f\u3081\u6955\u5186\u3067\u56f2\u3063\u305f\u4e00\u6b21\u95a2\u6570\u7684\u9818\u57df\u3088\u308a\u3082\u53f3\u5074\u306b\u30d7\u30ed\u30c3\u30c8\u304c\u51fa\u308b\u7279\u9577\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u53f3\u5074\u306b\u51fa\u305f\u9818\u57df\u306e\u30d7\u30ed\u30c3\u30c8\u3092\u907f\u3051\u3066\u6955\u5186\u3067\u56f2\u3063\u305f\u9818\u57df\u306e\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u7d30\u80de\u306e\u9818\u57df\u3060\u3051\u3092\u9078\u3093\u3067\u30b2\u30fc\u30c8\u3059\u308b\u4e8b\u3092\u201c\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u201d\u3068\u547c\u3073\u307e\u3059\u3002<\/p>\n<h2>\u5b9f\u969b\u306b\u30b7\u30f3\u30b0\u30eb\u3068\u30c0\u30d6\u30ec\u30c3\u30c8\u9818\u57df\u306e\u7d30\u80de\u306e\u5199\u771f\u3092\u898b\u3066\u307f\u3088\u3046<\/h2>\n<p>\u5b9f\u969b\u306b\u3001Attune CytPix Flow Cytometer\u3067\u6e2c\u5b9a\u3057\u305fJurkat\u7d30\u80de\u306e\u30d7\u30ed\u30c3\u30c8\u3067\u3001\u3054\u7d39\u4ecb\u3057\u305f\u65b9\u6cd5\u306b\u3088\u308b\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u7d30\u80de\u3068\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u306e\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u884c\u3044\u307e\u3057\u305f\u3002Attune CytPix Flow Cytometer\u306f\u30b2\u30fc\u30c8\u3057\u305f\u9818\u57df\u306e\u7d30\u80de\u306e\u59ff\u3092\u5b9f\u969b\u306b\u5199\u771f\u3067\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u6b21\u306e\u52d5\u753b\u3067\u3001\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u69d8\u5b50\u3092\u4e00\u7dd2\u306b\u78ba\u8a8d\u3057\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u3068\u30c0\u30d6\u30ec\u30c3\u30c8\u3092\u30b2\u30fc\u30c8\u3067\u304d\u305f\u304b\u5199\u771f\u3067\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<figure class=\"wp-block-video\">\n  <video controls=\"\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/295af63a9138f1e212da4521ffcd5acc.mp4\" playsinline width=\"640\"><\/video><br \/>\n<\/figure>\n<p>\u6b21\u306e\u56f33\u306b\u3001\u52d5\u753b\u3067\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u30d7\u30ed\u30c3\u30c8\u3068\u7d30\u80de\u306e\u5199\u771f\u306e\u4e00\u90e8\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13038\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3.jpg\" alt=\"\" width=\"1730\" height=\"1107\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3.jpg 1730w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3-300x192.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3-1024x655.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3-768x491.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/11\/Figure-3-1536x983.jpg 1536w\" sizes=\"auto, (max-width: 1730px) 100vw, 1730px\" \/><\/p>\n<p style=\"text-align: center\"><b>\u56f33. \u30d7\u30ed\u30c3\u30c8\u3068\u5b9f\u969b\u306e\u7d30\u80de\u306e\u5199\u771f<\/b><\/p>\n<p>\u3054\u89a7\u3044\u305f\u3060\u304d\u307e\u3057\u305f\u3088\u3046\u306b\u3001\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u7d30\u80de\u3092\u30b2\u30fc\u30c8\u3059\u308b\u9818\u57df\u201cSingle cell\u201d\u3067\u30b2\u30fc\u30c8\u3057\u305f\u7d30\u80de\u306e\u5199\u771f\u306f\u3044\u305a\u308c\u3082\u5358\u96e2\u7d30\u80de\u3067\u3042\u308b\u4e8b\u306b\u5bfe\u3057\u3066\u3001\u30c0\u30d6\u30ec\u30c3\u30c8\u3092\u30b2\u30fc\u30c8\u3059\u308b\u9818\u57df\u201cDoublet\u201d\u3067\u30b2\u30fc\u30c8\u3057\u305f\u7d30\u80de\u306e\u5199\u771f\u306f\u3044\u305a\u308c\u3082\u3001\u8907\u6570\u306e\u7d30\u80de\u304c\u9023\u306a\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u69d8\u5b50\u3092\u78ba\u8a8d\u3059\u308b\u4e8b\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3054\u7d39\u4ecb\u3057\u305f\u65b9\u6cd5\u3067\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u884c\u3044\u3001\u5b9f\u969b\u306b\u30b2\u30fc\u30c8\u3057\u305f\u9818\u57df\u306e\u7d30\u80de\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u3001\u30b7\u30f3\u30b0\u30ec\u30c3\u30c8\u9818\u57df\u306e\u7d30\u80de\u306f\u5358\u7d30\u80de\u3001\u30c0\u30d6\u30ec\u30c3\u30c8\u9818\u57df\u306e\u7d30\u80de\u3067\u306f\u8907\u6570\u306e\u7d30\u80de\u304c\u9023\u306a\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u69d8\u5b50\u304c\u5b9f\u969b\u306e\u5199\u771f\u3067\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002\u4eca\u307e\u3067\u3053\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306b\u95a2\u3057\u3066\u3001\u7406\u5c48\u306e\u4e0a\u3067\u306f\u30c0\u30d6\u30ec\u30c3\u30c8\u30b2\u30fc\u30c8\u306e\u9818\u57df\u306f\u8907\u6570\u306e\u7d30\u80de\u304c\u9023\u306a\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u4e8b\u306f\u5206\u304b\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u5b9f\u969b\u306b\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u4e0a\u306e\u30d7\u30ed\u30c3\u30c8\u3068\u5199\u771f\u30c7\u30fc\u30bf\u306e\u53cc\u65b9\u304b\u3089\u78ba\u8a8d\u3059\u308b\u3068\u3044\u3046\u4e8b\u306f\u6280\u8853\u7684\u306b\u96e3\u3057\u304b\u3063\u305f\u305f\u3081\u78ba\u8a8d\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u4eca\u56de\u3001Attune CytPix Flow Cytometer\u3092\u4f7f\u3046\u4e8b\u3067\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u4e3b\u5f35\u3059\u308b\u30c7\u30fc\u30bf\u3068\u7d30\u80de\u306e\u5f62\u72b6\u60c5\u5831\u3092\u4e00\u81f4\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002\u30c0\u30d6\u30ec\u30c3\u30c8\u306b\u9650\u3089\u305a\u3001\u8caa\u98df\u3084\u7d30\u80de\u5468\u671f\u306a\u3069\u3001\u7406\u5c48\u3068\u3057\u3066\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u4e0a\u3067\u793a\u3055\u308c\u308b\u30c7\u30fc\u30bf\u306b\u753b\u50cf\u60c5\u5831\u3092\u4ed8\u4e0e\u3059\u308b\u3053\u3068\u3067\u6e2c\u5b9a\u306e\u7cbe\u5ea6\u3084\u78ba\u5ea6\u3092\u9ad8\u3081\u308b\u4e8b\u304c\u3067\u304d\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u30fb\u672c\u30d6\u30ed\u30b0\u3067\u7d39\u4ecb\u3057\u305f\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6027\u80fd\u3092\u5f37\u5316\u3057\u305f\u52b9\u7387\u7684\u3067\u67d4\u8edf\u6027\u306e\u9ad8\u3044\u3001\u9769\u65b0\u7684\u306a\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fcAttune CytPix Flow Cytometer\u306b\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-nxt-flow-cytometer\/models\/cytpix.html?CID=Bid_pca_fin_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_fpl1_workshop_attune_flowcytometer_bid_ts_1_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u3061\u3089<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011Attune Acoustic Focusing Cytometer \u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u96c6<\/h3>\n<p>\u7d20\u65e9\u304f\u3001\u7c21\u5358\u3001\u8a70\u307e\u308a\u3065\u3089\u3044\uff01 \u89e3\u6790\u306b\u7279\u5316\u3057\u305f\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fcAttune NxT Flow Cytometer\u3092\u4f7f\u7528\u3057\u305f\u5b9f\u4f8b\u3068\u5b9f\u9a13\u624b\u6cd5\u3092\u307e\u3068\u3081\u305f\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u96c6\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-acoustic-focusing-flow-cytometer\/attune-appnote-catalog.html?CID=Bid_pca_fin_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_fpl1_workshop_attune_flowcytometer_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>Attune Flow Cytometers \u30c7\u30e2\u4f9d\u983c\u3001\u898b\u7a4d\u3082\u308a\u304a\u3088\u3073\u8cc7\u6599\u8acb\u6c42\u30d5\u30a9\u30fc\u30e0<\/h3>\n<p>\u3053\u306e\u30d6\u30ed\u30b0\u3067\u3054\u7d39\u4ecb\u3057\u305fInvitrogen\u2122 Attune\u2122 CytPix\u2122 Flow Cytometer\u306e\u8cc7\u6599\u8acb\u6c42\u3084\u30c7\u30e2\u4f9d\u983c\u306f\u4e0b\u8a18\u30dc\u30bf\u30f3\u304b\u3089\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/attune-nxt-acoustic-focusing-cytometer-quote-form.html?CID=Bid_pca_fin_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_fpl1_workshop_attune_flowcytometer_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u4ed6\u306b\u3082\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3092\u59cb\u3081\u3068\u3057\u305f\u3001\u5404\u7a2e\u7d30\u80de\u57f9\u990a\u3001\u7d30\u80de\u89e3\u6790\u306b\u95a2\u3059\u308b\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u5b9f\u65bd\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u53c2\u52a0\u3054\u5e0c\u671b\u306e\u65b9\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html#t4?cid=Bid_pca_fin_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_fpl1_workshop_attune_flowcytometer_bid_ts_1_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u3061\u3089<\/a>\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u89e3\u6790\u306e\u305f\u3081\u306b\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u969b\u306b\u826f\u304f\u5b9f\u65bd\u3055\u308c\u308b\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u3002\u540c\u3058\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306eArea(\u3082\u3057\u304f\u306fWidth)\u3068Height\u3067\u30c9\u30c3\u30c8\u30d7\u30ed\u30c3\u30c8\u3092\u5c55\u958b\u3059\u308b\u4e8b\u3067\u3001\u8907\u6570\u500b\u306e\u7d30\u80de\u304c\u56fa\u307e\u3063\u305f\u30d7\u30ed\u30c3\u30c8\uff08\u30c0\u30d6\u30ec\u30c3\u30c8<\/p>\n","protected":false},"author":975,"featured_media":14188,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[76,28],"division":[],"class_list":["post-13036","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-flow-cytometry","tag-experiment","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u89e3\u6790\u306e\u305f\u3081\u306b\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u969b\u306b\u826f\u304f\u5b9f\u65bd\u3055\u308c\u308b\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u3002\u540c\u3058\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306eArea(\u3082\u3057\u304f\u306fWidth)\u3068Height\u3067\u30c9\u30c3\u30c8\u30d7\u30ed\u30c3\u30c8\u3092\u5c55\u958b\u3059\u308b\u4e8b\u3067\u3001\u8907\u6570\u500b\u306e\u7d30\u80de\u304c\u56fa\u307e\u3063\u305f\u30d7\u30ed\u30c3\u30c8\uff08\u30c0\u30d6\u30ec\u30c3\u30c8\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-05T01:32:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-18T09:19:34+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"571\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f\",\"datePublished\":\"2022-12-05T01:32:19+00:00\",\"dateModified\":\"2026-02-18T09:19:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/\"},\"wordCount\":89,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_2060448125.jpg\",\"keywords\":[\"\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\",\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_2060448125.jpg\",\"datePublished\":\"2022-12-05T01:32:19+00:00\",\"dateModified\":\"2026-02-18T09:19:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_2060448125.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_2060448125.jpg\",\"width\":1000,\"height\":571,\"caption\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/workshop_attune_flowcytometer_bid_ts_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f","og_description":"\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3067\u89e3\u6790\u306e\u305f\u3081\u306b\u30b2\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u969b\u306b\u826f\u304f\u5b9f\u65bd\u3055\u308c\u308b\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u3002\u540c\u3058\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306eArea(\u3082\u3057\u304f\u306fWidth)\u3068Height\u3067\u30c9\u30c3\u30c8\u30d7\u30ed\u30c3\u30c8\u3092\u5c55\u958b\u3059\u308b\u4e8b\u3067\u3001\u8907\u6570\u500b\u306e\u7d30\u80de\u304c\u56fa\u307e\u3063\u305f\u30d7\u30ed\u30c3\u30c8\uff08\u30c0\u30d6\u30ec\u30c3\u30c8","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-12-05T01:32:19+00:00","article_modified_time":"2026-02-18T09:19:34+00:00","og_image":[{"width":1000,"height":571,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f","datePublished":"2022-12-05T01:32:19+00:00","dateModified":"2026-02-18T09:19:34+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/"},"wordCount":89,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","keywords":["\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc","\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","datePublished":"2022-12-05T01:32:19+00:00","dateModified":"2026-02-18T09:19:34+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","width":1000,"height":571,"caption":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop_attune_flowcytometer_bid_ts_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u306e\u30c0\u30d6\u30ec\u30c3\u30c8\u9664\u53bb\u306f\u672c\u5f53\u306b\u30c0\u30d6\u30ec\u30c3\u30c8\u7d30\u80de\u7fa4\u3092\u9664\u53bb\u3067\u304d\u3066\u3044\u308b\u306e\u304b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":76,"label":"\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc"},{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg",760,434,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":76,"name":"\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc","slug":"flow-cytometry","term_group":0,"term_taxonomy_id":76,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]},{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25623,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-flow-cytometry-ts-r-25069\/","url_meta":{"origin":13036,"position":0},"title":"\u3010\u7b2c9\u56de\u3011 \u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u7528\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u56de\u53ce","author":"LatB Staff","date":"2026\u5e7410\u670830\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30ca\u30ce\u30b5\u30a4\u30ba\u306e\u5c0f\u80de\uff08\u76f4\u5f8430\uff5e100 nm\uff09\u3067\u3042\u308b\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u3092\u3001\u78c1\u6c17\u30d3\u30fc\u30ba\uff08Invitro\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":13036,"position":1},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":13036,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":13036,"position":3},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":13036,"position":4},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":13036,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_2060448125.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13036","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13036"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13036\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14188"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13036"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13036"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13036"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13036"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}