{"id":13149,"date":"2022-12-21T12:50:50","date_gmt":"2022-12-21T03:50:50","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13149"},"modified":"2025-02-07T16:05:42","modified_gmt":"2025-02-07T07:05:42","slug":"foreign_material_ft-ir_msd_sales8","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/","title":{"rendered":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1"},"content":{"rendered":"<p>\u8eab\u8fd1\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u6a39\u8102\u306a\u3069\u306e\u6750\u6599\u306f\u4f7f\u7528\u72b6\u6cc1\u3084\u671f\u9593\u306a\u3069\u306b\u3088\u308a\u5909\u8272\u3057\u305f\u308a\u7834\u640d\u3057\u3084\u3059\u304f\u306a\u308b\u306a\u3069\u306e\u52a3\u5316\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u52a3\u5316\u6a39\u8102\u306e\u8a55\u4fa1\u306bFT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u304a\u3088\u3073\u30e9\u30de\u30f3\u5206\u5149\u5149\u5ea6\u8a08\u304c\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n\u3053\u306e\u30d6\u30ed\u30b0\u8a18\u4e8b\u3067\u306f\u5b9f\u4f8b\u3092\u4ea4\u3048\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<h2>\u52a3\u5316\u306e\u4e3b\u306a\u30e1\u30ab\u30cb\u30ba\u30e0<\/h2>\n<p>\u6a39\u8102\u6750\u6599\u306e\u52a3\u5316\u304c\u8d77\u3053\u308b\u539f\u56e0\u306f\u591a\u5c90\u306b\u308f\u305f\u308a\u307e\u3059\u304c\u3001\u4e3b\u306a\u8981\u56e0\u3068\u3057\u3066\u3001\u5149\uff08\u7d2b\u5916\u7dda\uff09\u3001\u71b1\u3001\u74b0\u5883\u4e2d\u306e\u30ac\u30b9\u3084\u6c34\u5206\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u52a3\u5316\u904e\u7a0b\u306b\u304a\u3044\u3066\u306f\u3053\u308c\u3089\u304c\u8907\u96d1\u306b\u95a2\u4e0e\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u660e\u78ba\u306b\u89e3\u660e\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059\u3002\u6a39\u8102\u6750\u6599\u3067\u3088\u304f\u898b\u3089\u308c\u308b\u52a3\u5316\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u4e00\u3064\u306b\u81ea\u52d5\u9178\u5316\u306b\u3088\u308b\u9178\u5316\u52a3\u5316\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u30b5\u30a4\u30af\u30eb\u306b\u3088\u308a\u3001\u6a39\u8102\u306e\u69cb\u9020\u304c\u5909\u5316\u3057\u3001\u5206\u5b50\u4e2d\u306bC=O\u3001COOH\u3001RCOOR\u306a\u3069\u306e\u69cb\u9020\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13152\" style=\"width: 394px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13152\" class=\"wp-image-13152 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/795316b92fc766b0181f6fef074f03fa-1.jpg\" alt=\"\u81ea\u52d5\u9178\u5316\u6a5f\u69cb\u306e\u6982\u8981\" width=\"384\" height=\"289\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/795316b92fc766b0181f6fef074f03fa-1.jpg 384w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/795316b92fc766b0181f6fef074f03fa-1-300x226.jpg 300w\" sizes=\"auto, (max-width: 384px) 100vw, 384px\" \/><p id=\"caption-attachment-13152\" class=\"wp-caption-text\">\u56f31\uff1a\u81ea\u52d5\u9178\u5316\u6a5f\u69cb\u306e\u6982\u8981<\/p><\/div>\n<h2>\u96fb\u5316\u88fd\u54c1\u306e\u5909\u8272<\/h2>\n<p>10\u5e74\u4ee5\u4e0a\u4f7f\u7528\u3057\u3066\u3044\u308b\u96fb\u8a71\u6a5f\u306e\u53d7\u8a71\u5668\u30fb\u30d1\u30cd\u30eb\u306e\u6a39\u8102\u306f\u3082\u3068\u3082\u3068\u767d\u8272\u3067\u3057\u305f\u304c\u3001\u9ec4\u8272\u304f\u5909\u8272\u3057\u3066\u3044\u308b\u69d8\u5b50\u304c\u307f\u3089\u308c\u307e\u3057\u305f\u3002\u53d7\u8a71\u5668\u90e8\u5206\u306b\u3064\u3044\u3066\u3001\u8868\u9762\u4ed8\u8fd1\u3068\u5185\u90e8\u3092\u5c11\u3057\u524a\u308a\u53d6\u308a\u3001FT-IR\u306b\u3088\u308bATR\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u53d7\u8a71\u5668\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u7d20\u6750\u306fABS\u6a39\u8102\u3067\u3042\u308a\u3001\u8868\u9762\u306e\u30b9\u30da\u30af\u30c8\u30eb\u306f\u9178\u5316\u52a3\u5316\u306b\u3088\u308b\u69cb\u9020\u5909\u5316\u3092\u53d7\u3051\u3001OH\u69cb\u9020\u3084C=O\u69cb\u9020\u306b\u7531\u6765\u3059\u308b\u30d4\u30fc\u30af\u304c\u89b3\u6e2c\u3055\u308c\u307e\u3057\u305f\u3002\u5185\u90e8\u306b\u3064\u3044\u3066\u306f\u3053\u308c\u3089\u306e\u30d4\u30fc\u30af\u306f\u5b58\u5728\u305b\u305a\u3001\u52a3\u5316\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_13153\" style=\"width: 467px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13153\" class=\"wp-image-13153 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/2b530e80c7d0de90885e285c5d798063-2.jpg\" alt=\"\u53d7\u8a71\u5668\u8868\u9762\u304a\u3088\u3073\u5185\u90e8\u306eATR\u30b9\u30da\u30af\u30c8\u30eb\" width=\"457\" height=\"286\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/2b530e80c7d0de90885e285c5d798063-2.jpg 457w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/2b530e80c7d0de90885e285c5d798063-2-300x188.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/2b530e80c7d0de90885e285c5d798063-2-320x200.jpg 320w\" sizes=\"auto, (max-width: 457px) 100vw, 457px\" \/><p id=\"caption-attachment-13153\" class=\"wp-caption-text\">2\uff1a\u53d7\u8a71\u5668\u8868\u9762\uff08\u4e0a\uff09\u304a\u3088\u3073\u5185\u90e8\uff08\u4e0b\uff09\u306eATR\u30b9\u30da\u30af\u30c8\u30eb<\/p><\/div>\n<h2>\u8d64\u5916\u9855\u5fae\u93e1\u306b\u3088\u308b\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a<\/h2>\n<p>\u52a3\u5316\u304c\u8868\u9762\u3088\u308a\u3069\u306e\u7a0b\u5ea6\u307e\u3067\u9032\u3093\u3067\u3044\u308b\u306e\u304b\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001\u53d7\u8a71\u5668\u306e\u4e00\u90e8\u306b\u3064\u3044\u3066\u65ad\u9762\u306e\u5207\u7247\u3092\u4f5c\u6210\u3057\u3001\u8d64\u5916\u9855\u5fae\u93e1\u306b\u3066\u900f\u904e\u306b\u3088\u308b\u300c\u8d85\u9ad8\u901f\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a\u300d\u3092\u884c\u3044\u307e\u3057\u305f\u3002<br \/>\n\u52a3\u5316\u306b\u3088\u308a\u751f\u6210\u3057\u305fC=O\u69cb\u9020\u306b\u7531\u6765\u3059\u308b1724 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306e\u30d4\u30fc\u30af\u9ad8\u3055\u3092\u7528\u3044\u3066\u89e3\u6790\u3092\u884c\u3063\u305f\u3068\u3053\u308d\u3001\u4ee5\u4e0b\u306e\u30b1\u30df\u30ab\u30eb\u30a4\u30e1\u30fc\u30b8\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u8868\u9762\u4ed8\u8fd1\u3067C=O\u30d4\u30fc\u30af\u304c\u9ad8\u3044\u69d8\u5b50\u304c\u898b\u3089\u308c\u3001\u5185\u90e8\u306b\u304b\u3051\u3066\u5c0f\u3055\u304f\u306a\u3063\u3066\u3044\u304f\u69d8\u5b50\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u8868\u9762\u304b\u3089\u9178\u5316\u306b\u3088\u308b\u52a3\u5316\u304c\u8d77\u3053\u308a\u3001\u304a\u3088\u305d600 \u03bcm\u306e\u6df1\u3055\u307e\u3067\u52a3\u5316\u304c\u9032\u3093\u3067\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_13150\" style=\"width: 668px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13150\" class=\"wp-image-13150 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/c8856789ec11ab8b1013037cef6929f9-2.jpg\" alt=\"\u53d7\u8a71\u5668\u65ad\u9762\u5207\u7247\u306e\u53ef\u8996\u753b\u50cf\u304a\u3088\u3073\u30b1\u30df\u30ab\u30eb\u30a4\u30e1\u30fc\u30b8\u3068\u53ef\u8996\u753b\u50cf\u3068\u306e\u91cd\u306d\u304c\u304d\" width=\"658\" height=\"325\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/c8856789ec11ab8b1013037cef6929f9-2.jpg 658w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/c8856789ec11ab8b1013037cef6929f9-2-300x148.jpg 300w\" sizes=\"auto, (max-width: 658px) 100vw, 658px\" \/><p id=\"caption-attachment-13150\" class=\"wp-caption-text\">\u56f33\uff1a\u53d7\u8a71\u5668\u65ad\u9762\u5207\u7247\u306e\u53ef\u8996\u753b\u50cf\uff08\u5de6\uff09\u304a\u3088\u3073\u30b1\u30df\u30ab\u30eb\u30a4\u30e1\u30fc\u30b8\u3068\u53ef\u8996\u753b\u50cf\u3068\u306e\u91cd\u306d\u304c\u304d\uff08\u53f3\uff09<\/p><\/div>\n<h2>\u30e9\u30de\u30f3\u5206\u5149\u6e2c\u5b9a<\/h2>\n<p>\u7d9a\u3044\u3066\u3001\u30e9\u30de\u30f3\u5206\u5149\u5149\u5ea6\u8a08\u3092\u7528\u3044\u3066\u8868\u9762\u3068\u5185\u90e8\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u6e2c\u5b9a\u3092\u884c\u3044\u3001\u8a55\u4fa1\u3092\u8a66\u307f\u307e\u3057\u305f\u3002\u8868\u9762\u3068\u5185\u90e8\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u6bd4\u8f03\u3059\u308b\u3068\u30011600 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306e\u30d9\u30f3\u30bc\u30f3\u74b0\uff08\u82b3\u9999\u74b0\uff09\u7531\u6765C=C\u7d50\u5408\u306e\u30d4\u30fc\u30af\u306b\u5909\u5316\u306f\u307b\u307c\u898b\u3089\u308c\u307e\u305b\u3093\u304c\u30011650 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC=C\u7d50\u5408\u7531\u6765\u30d4\u30fc\u30af\u304c\u8868\u9762\u3067\u307b\u307c\u6d88\u5931\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u6a39\u8102\u306e\u7d20\u6750\u304cABS\u3067\u3042\u308b\u3053\u3068\u304b\u3089\u3001\u30d6\u30bf\u30b8\u30a8\u30f3\u306eC=C\u69cb\u9020\u304c\u52a3\u5316\u306b\u3088\u308a\u5909\u5316\u3057\u3001\u6e1b\u5c11\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13151\" style=\"width: 490px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13151\" class=\"wp-image-13151 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/3a4f695a458cb0ac0aceaa2eb13ac2dd-2.jpg\" alt=\"\u53d7\u8a71\u5668\u8868\u9762\uff08\u52a3\u5316\u90e8\uff09\u30fb\u5185\u90e8\uff08\u672a\u52a3\u5316\u90e8\uff09\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u6bd4\u8f03\" width=\"480\" height=\"363\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/3a4f695a458cb0ac0aceaa2eb13ac2dd-2.jpg 480w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/3a4f695a458cb0ac0aceaa2eb13ac2dd-2-300x227.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><p id=\"caption-attachment-13151\" class=\"wp-caption-text\">\u56f34\uff1a\u53d7\u8a71\u5668\u8868\u9762\uff08\u52a3\u5316\u90e8\uff09\u30fb\u5185\u90e8\uff08\u672a\u52a3\u5316\u90e8\uff09\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u6bd4\u8f03<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u6a39\u8102\u306e\u52a3\u5316\u6a5f\u69cb\u3084\u305d\u306e\u539f\u56e0\u306f\u591a\u5c90\u306b\u308f\u305f\u308a\u3001FT-IR\u3084\u30e9\u30de\u30f3\u5206\u6790\u3067\u305d\u306e\u3059\u3079\u3066\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059\u304c\u3001\u4eca\u56de\u306e\u4e8b\u4f8b\u3067\u306f\u3001\u6bd4\u8f03\u7684\u8eab\u8fd1\u306b\u8d77\u3053\u308a\u3046\u308b\u73fe\u8c61\u3067\u3042\u308b\u81ea\u52d5\u9178\u5316\u306b\u3088\u308b\u6a39\u8102\u81ea\u4f53\u306e\u9178\u5316\u52a3\u5316\u306b\u3064\u3044\u3066\u3001\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u3084\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u304b\u3089\u52a3\u5316\u306b\u3088\u308b\u6a39\u8102\u306e\u69cb\u9020\u5909\u5316\u3092\u63a8\u6e2c\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<br \/>\n\u8a73\u7d30\u306b\u3064\u304d\u307e\u3057\u3066\u306f\u4e0b\u8a18\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><b>\u95a2\u9023\u60c5\u5831<\/b><br \/>\n1 \u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u3000<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/application-note-ftir056-degradation-assessment-ja.pdf\" target=\"_blank\" rel=\"noopener\">FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1<\/a><br \/>\n2 \u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8 \u2192 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fourier-transform-infrared-ftir-spectroscopy\/ftir-instruments.html?CID=foreign_material_ft-ir_msd_sales_8_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 Nicolet\u2122 FT-IR\u5206\u5149\u5149\u5ea6\u8a08<\/a><br \/>\n3 \u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8 \u2192 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/raman-spectroscopy.html?CID=foreign_material_ft-ir_msd_sales_8_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30e9\u30de\u30f3\u5206\u5149\u6cd5<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><b>FT-IR\u88fd\u54c1\u306b\u3064\u3044\u3066\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u3092\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/b><br \/>\n\u30c7\u30e2\u4f7f\u7528\u3084\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3054\u5e0c\u671b\u306e\u65b9\u306f\u4e0b\u8a18\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/ftir-inquiry-form.html?CID=foreign_material_ft-ir_msd_sales_8_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8eab\u8fd1\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u6a39\u8102\u306a\u3069\u306e\u6750\u6599\u306f\u4f7f\u7528\u72b6\u6cc1\u3084\u671f\u9593\u306a\u3069\u306b\u3088\u308a\u5909\u8272\u3057\u305f\u308a\u7834\u640d\u3057\u3084\u3059\u304f\u306a\u308b\u306a\u3069\u306e\u52a3\u5316\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u52a3\u5316\u6a39\u8102\u306e\u8a55\u4fa1\u306bFT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u304a\u3088\u3073\u30e9\u30de\u30f3\u5206\u5149\u5149\u5ea6\u8a08\u304c\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u3053\u306e\u30d6\u30ed\u30b0\u8a18<\/p>\n","protected":false},"author":975,"featured_media":14186,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[194],"division":[],"class_list":["post-13149","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-ir","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1\" \/>\n<meta property=\"og:description\" content=\"\u8eab\u8fd1\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u6a39\u8102\u306a\u3069\u306e\u6750\u6599\u306f\u4f7f\u7528\u72b6\u6cc1\u3084\u671f\u9593\u306a\u3069\u306b\u3088\u308a\u5909\u8272\u3057\u305f\u308a\u7834\u640d\u3057\u3084\u3059\u304f\u306a\u308b\u306a\u3069\u306e\u52a3\u5316\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u52a3\u5316\u6a39\u8102\u306e\u8a55\u4fa1\u306bFT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u304a\u3088\u3073\u30e9\u30de\u30f3\u5206\u5149\u5149\u5ea6\u8a08\u304c\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u3053\u306e\u30d6\u30ed\u30b0\u8a18\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-21T03:50:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-07T07:05:42+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1\",\"datePublished\":\"2022-12-21T03:50:50+00:00\",\"dateModified\":\"2025-02-07T07:05:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/\"},\"wordCount\":68,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_749410411.jpg\",\"keywords\":[\"\u8d64\u5916\u5206\u5149\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/\",\"name\":\"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_749410411.jpg\",\"datePublished\":\"2022-12-21T03:50:50+00:00\",\"dateModified\":\"2025-02-07T07:05:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_749410411.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/shutterstock_749410411.jpg\",\"width\":1000,\"height\":667,\"caption\":\"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales8\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/","og_locale":"ja_JP","og_type":"article","og_title":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1","og_description":"\u8eab\u8fd1\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u6a39\u8102\u306a\u3069\u306e\u6750\u6599\u306f\u4f7f\u7528\u72b6\u6cc1\u3084\u671f\u9593\u306a\u3069\u306b\u3088\u308a\u5909\u8272\u3057\u305f\u308a\u7834\u640d\u3057\u3084\u3059\u304f\u306a\u308b\u306a\u3069\u306e\u52a3\u5316\u304c\u898b\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u52a3\u5316\u6a39\u8102\u306e\u8a55\u4fa1\u306bFT-IR\uff08\u8d64\u5916\u5206\u5149\u5149\u5ea6\u8a08\uff09\u304a\u3088\u3073\u30e9\u30de\u30f3\u5206\u5149\u5149\u5ea6\u8a08\u304c\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u3053\u306e\u30d6\u30ed\u30b0\u8a18","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2022-12-21T03:50:50+00:00","article_modified_time":"2025-02-07T07:05:42+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1","datePublished":"2022-12-21T03:50:50+00:00","dateModified":"2025-02-07T07:05:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/"},"wordCount":68,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","keywords":["\u8d64\u5916\u5206\u5149\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/","name":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","datePublished":"2022-12-21T03:50:50+00:00","dateModified":"2025-02-07T07:05:42+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","width":1000,"height":667,"caption":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales8\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":194,"label":"\u8d64\u5916\u5206\u5149\u6cd5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":194,"name":"\u8d64\u5916\u5206\u5149\u6cd5","slug":"ir","term_group":0,"term_taxonomy_id":194,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25000,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nalgene-safety-control-lpd-26013\/","url_meta":{"origin":13149,"position":0},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306e\u8010\u85ac\u54c1\u6027\u3068\u6c17\u5bc6\u6027\u3068\u306f\uff1f\uff5e \u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u672c\u306e\u8a71\uff5e","author":"LatB Staff","date":"2026\u5e743\u670826\u65e5","format":false,"excerpt":"\u30dc\u30c8\u30eb\u9078\u3073\u3001\u306a\u3093\u3068\u306a\u304f\u3067\u5927\u4e08\u592b\uff1f \u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30dc\u30c8\u30eb\u306f\u3001\u30dc\u30c8\u30eb\u306e\u6a39\u8102\u3068\u5185\u5bb9\u7269\u306e\u76f8\u6027\u304c\u9069\u5207\u3067\u306a\u3044\u5834\u5408\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24627,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-semiconductors-lpd-26006\/","url_meta":{"origin":13149,"position":1},"title":"\u9078\u3070\u308c\u308b\u7406\u7531\u304c\u3042\u308b\uff1aThermo Scientific\u771f\u7a7a\u30aa\u30fc\u30d6\u30f3\uff5e\u9ad8\u6e29\u30fb\u9ad8\u771f\u7a7a\u304c\u751f\u307f\u51fa\u3059\u3001\u7cbe\u5bc6\u30d7\u30ed\u30bb\u30b9\u3068\u4fe1\u983c\u6027\uff5e","author":"LatB Staff","date":"2026\u5e741\u670830\u65e5","format":false,"excerpt":"\u88fd\u54c1\u3084\u6750\u6599\u306e\u54c1\u8cea\u3092\u9ad8\u3081\u308b\u3046\u3048\u3067\u3001\u4e7e\u71e5\u30fb\u52a0\u71b1\u30fb\u8131\u6ce1\u3068\u3044\u3063\u305f\u30d7\u30ed\u30bb\u30b9\u306f\u6b20\u304b\u305b\u306a\u3044\u8981\u7d20\u3067\u3059\u3002\u305d\u306e\u4e2d\u3067\u3082\u3001\u6e29\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":13149,"position":2},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":13149,"position":3},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":13149,"position":4},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25170,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody-purification-vaccine-bpg-26018\/","url_meta":{"origin":13149,"position":5},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\u7cbe\u88fd\u306e\u57fa\u790e\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u6a39\u8102\u9078\u629e","author":"LatB Staff","date":"2026\u5e745\u670819\u65e5","format":false,"excerpt":"\u5c0e\u5165 \u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\uff08bispecific antibody\u3001\u4ee5\u4e0bBsAb\uff09\u306f\u30012\u3064\u306e\u7570\u306a\u308b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/shutterstock_749410411.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13149"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13149\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14186"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13149"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}