{"id":13230,"date":"2023-01-24T14:46:23","date_gmt":"2023-01-24T05:46:23","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13230"},"modified":"2025-03-10T11:09:43","modified_gmt":"2025-03-10T02:09:43","slug":"elisa-workshop-bid-ts-3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/","title":{"rendered":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f"},"content":{"rendered":"<p>\u30b5\u30f3\u30c9\u30a4\u30c3\u30c1ELISA\u306e\u7cfb\u3092\u81ea\u4f5c\u3067\u69cb\u7bc9\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u6297\u4f53\u30da\u30a2\u306e\u9078\u5b9a\u3001\u691c\u91cf\u7dda\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9078\u5b9a\u3001\u6297\u4f53\u6fc3\u5ea6\u3001\u53cd\u5fdc\u6642\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u2026\u3068\u6570\u591a\u304f\u306e\u6761\u4ef6\u691c\u8a0e\u304c\u5fc5\u8981\u3067\u3059\u3002<br \/>\n\u30b9\u30c6\u30c3\u30d7\u6570\u3082\u591a\u3044\u306e\u3067\u3001\u4f55\u3092\u3069\u3046\u6761\u4ef6\u691c\u8a0e\u3059\u308c\u3070\u3088\u3044\u304b\u60a9\u3080\u65b9\u3082\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u305d\u3053\u3067\u4eca\u56de\u306fCapture Antibody\uff08\u6355\u6349\u6297\u4f53\uff09\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3057\u3001\u6297\u4f53\u6fc3\u5ea6\u3092\u5909\u66f4\u3059\u308b\u3068\u7d50\u679c\u304c\u3069\u3046\u5909\u5316\u3059\u308b\u304b\u3092\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u3053\u308c\u304b\u3089\u81ea\u4f5cELISA\u3092\u69cb\u7bc9\u3057\u305f\u3044<br \/>\n\u30fbELISA\u306e\u6761\u4ef6\u691c\u8a0e\u3067\u60a9\u3093\u3067\u3044\u308b<\/p>\n<h2>\u6750\u6599\u3068\u65b9\u6cd5<\/h2>\n<p><b>\u6750\u6599\uff1a<\/b><br \/>\nInvitrogen\u2122<a href=\"https:\/\/www.thermofisher.com\/elisa\/product\/IL-6-Mouse-Uncoated-ELISA-Kit-with-Plates\/88-7064-86?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_elisa_workshop_bid_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">IL-6 Mouse Uncoated ELISA Kit with Plates<\/a> \uff0888-7064-88\uff09<\/p>\n<p><b>\u65b9\u6cd5\uff1a<\/b><br \/>\n\u30ad\u30c3\u30c8\u306b\u542b\u307e\u308c\u308bCapture Antibody\u306b\u3064\u3044\u3066\u3001\u30de\u30cb\u30e5\u30a2\u30eb\u63a8\u5968\u306e\u5e0c\u91c8\u7387\u304cx 250\u306e\u3068\u3053\u308d\u6fc3\u5ea6\u304c\u9ad8\u3044\u65b9\u304b\u3089\u9806\u306bx 62.5\u3001\uff58 125\u3001\uff58 250\u3001\uff58 500\u3001\uff58 1000\u3001\uff58 2000\u3001\u306e6\u7a2e\u985e\u306e\u5e0c\u91c8\u7387\u3067\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>\u30ad\u30c3\u30c8\u4ed8\u5c5e\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u5f93\u3044\u3001\u4ee5\u4e0b\u306e\u4f5c\u696d\u3092\u884c\u3044\u307e\u3057\u305f\u3002<br \/>\n\u30fb\u8abf\u88fd\u3057\u305f\u5404\u6fc3\u5ea6\u306eCapture Antibody\u3067\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0<br \/>\n\u30fb\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3092\u884c\u3044\u3001\u305d\u308c\u305e\u308c\u306b\u304a\u3044\u3066\u691c\u91cf\u7dda\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30b5\u30f3\u30d7\u30eb\uff087\u6bb5\u968e\uff09\u3092\u53cd\u5fdc<br \/>\n\u30fb\u6d17\u6d44\u3001\u305d\u306e\u5f8c\u306e\u53cd\u5fdc\u30b9\u30c6\u30c3\u30d7\u3092\u5b9f\u65bd<br \/>\nThermo Scientific\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-skyhigh.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_elisa_workshop_bid_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Multiskan SkyHigh Microplate Spectrophotometer<\/a>\u3067450 nm\u306e\u5438\u5149\u5ea6\u3092\u6e2c\u5b9a\u3057\u3001Thermo Scientific\u2122 SkanIt\u2122\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u89e3\u6790\u3057\u30014 parameter logistic curve\u3067\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002<\/p>\n<h2>\u7d50\u679c<\/h2>\n<p>\u5404\u5e0c\u91c8\u7387\u306b\u304a\u3051\u308b\u6e2c\u5b9a\u5024\u3092\u5229\u7528\u3057\u3001\u4f5c\u6210\u3055\u308c\u305f\u691c\u91cf\u7dda\u306f\u4e0b\u8a18\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n\u30de\u30cb\u30e5\u30a2\u30eb\u63a8\u5968\u306e\uff58 250\u3068\u6bd4\u8f03\u3057\u3001Capture Antibody\u306e\u6fc3\u5ea6\u304c\u3088\u308a\u4f4e\u3044\u5834\u5408\uff08\uff58 500\u3001\uff58 1000\u3001\uff582000\uff09\u3067\u306f\u3042\u307e\u308a\u5927\u304d\u304f\u5438\u5149\u5ea6\u304c\u5909\u308f\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u305d\u308c\u306b\u5bfe\u3057\u3066Capture Antibody\u306e\u6fc3\u5ea6\u304c\u3088\u308a\u9ad8\u3044\u5834\u5408\uff08x 62.5\u3001\uff58 125\uff09\u306f\u3001\u5438\u5149\u5ea6\u304c\u5927\u5e45\u306b\u843d\u3061\u308b\u3068\u3044\u3046\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<br \/>\n\uff08\u30a2\u30c3\u30bb\u30a4\u7cfb\u306b\u3088\u3063\u3066\u306f\u3001\u7d50\u679c\u306f\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\uff09<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13232\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png\" alt=\"\" width=\"901\" height=\"461\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png 901w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa-300x153.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa-768x393.png 768w\" sizes=\"auto, (max-width: 901px) 100vw, 901px\" \/><\/p>\n<h2>\u8003\u5bdf<\/h2>\n<p>Capture Antibody\u306e\u6fc3\u5ea6\u3092\u4e0b\u3052\u308b\u3068\u5438\u5149\u5ea6\u304c\u4e0b\u304c\u308b\u3068\u4e88\u60f3\u3057\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u4eca\u56de\u306e\u691c\u8a0e\u3057\u305f\u7bc4\u56f2\u3067\u306f\u5927\u304d\u306a\u5f71\u97ff\u306f\u898b\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u305f\u3060x 2000\u3067\u306f\u82e5\u5e72\u5438\u5149\u5ea6\u304c\u843d\u3061\u3066\u3044\u308b\u306e\u3067\u3001\u3055\u3089\u306b\u4f4e\u3044\u6fc3\u5ea6\u3067\u306f\u30b7\u30b0\u30ca\u30eb\u304c\u843d\u3061\u3066\u3044\u304f\u3053\u3068\u304c\u4e88\u60f3\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u307e\u305fCapture Antibody\u306e\u6fc3\u5ea6\u3092\u4e0a\u3052\u305f\u5834\u5408\uff08x 62.5\u3001x 125\uff09\u306f\u3001\u5438\u5149\u5ea6\u304c\u4e0a\u304c\u308b\u3068\u4e88\u60f3\u3057\u307e\u3057\u305f\u304c\u3001\u601d\u3044\u306e\u307b\u304b\u5927\u5e45\u306b\u4f4e\u3044\u5024\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u7406\u7531\u306f\u7279\u5b9a\u3067\u304d\u3066\u304a\u308a\u307e\u305b\u3093\u304c\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6642\u306e\u6297\u4f53\u6fc3\u5ea6\u304c\u9ad8\u3059\u304e\u308b\u3068\u3001\u30d7\u30ec\u30fc\u30c8\u4e0a\u306e\u6297\u4f53\u306e\u5bc6\u5ea6\u304c\u9ad8\u304f\u306a\u308a\u3059\u304e\u3066\u3001\u6297\u539f\u3068\u306e\u53cd\u5fdc\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u305f\u53ef\u80fd\u6027\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13233\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/31104301f30c20ee5603c7ce62b81254.png\" alt=\"\" width=\"987\" height=\"372\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/31104301f30c20ee5603c7ce62b81254.png 987w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/31104301f30c20ee5603c7ce62b81254-300x113.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/31104301f30c20ee5603c7ce62b81254-768x289.png 768w\" sizes=\"auto, (max-width: 987px) 100vw, 987px\" \/><br \/>\n\u4ee5\u4e0a\u306e\u7d50\u679c\u3088\u308a\u3001\u81ea\u4f5c\u3067ELISA\u306e\u5b9f\u9a13\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u969b\u306b\u306f\u5e83\u3044\u6297\u4f53\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u6761\u4ef6\u691c\u8a0e\u3092\u884c\u3046\u3053\u3068\u306e\u91cd\u8981\u6027\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30fbCapture Antibody\u306e\u6fc3\u5ea6\u304c\u4f4e\u3044\u3068\u3001\u6700\u7d42\u7684\u306b\u5f97\u3089\u308c\u308b\u5438\u5149\u5ea6\u306f\u4e0b\u304c\u308b<br \/>\n\u30fbCapture Antibody\u306e\u6fc3\u5ea6\u304c\u9ad8\u3059\u304e\u308b\u3068\u3001\u6297\u539f\u3068\u306e\u53cd\u5fdc\u306b\u5f71\u97ff\u304c\u3042\u308a\u5438\u5149\u5ea6\u304c\u4e0b\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b<br \/>\n\u30fb\u81ea\u4f5c\u3067ELISA\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u969b\u306b\u306f\u3001\u5e83\u3044\u6297\u4f53\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u6761\u4ef6\u691c\u8a0e\u3092\u884c\u3046\u3053\u3068\u304c\u91cd\u8981<\/p>\n<p>\u5f53\u793e\u3067\u306fELISA\u3060\u3051\u306a\u304f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3084\u7d30\u80de\u57f9\u990a\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306a\u3069\u3001\u5b9f\u969b\u306b\u5b9f\u9a13\uff08\u5b9f\u7fd2\uff09\u3092\u884c\u3044\u3064\u3064\u5b66\u3079\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_elisa_workshop_bid_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u5404\u7a2e\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e2d\u3067\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u7d50\u679c\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u3044\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3088\u308a\u7406\u89e3\u3092\u6df1\u3081\u305f\u3044\u65b9\u306f\u305c\u3072\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\uff01<\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_lgn_kt_s00_elisa_workshop_bid_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b5\u30f3\u30c9\u30a4\u30c3\u30c1ELISA\u306e\u7cfb\u3092\u81ea\u4f5c\u3067\u69cb\u7bc9\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u6297\u4f53\u30da\u30a2\u306e\u9078\u5b9a\u3001\u691c\u91cf\u7dda\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9078\u5b9a\u3001\u6297\u4f53\u6fc3\u5ea6\u3001\u53cd\u5fdc\u6642\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u2026\u3068\u6570\u591a\u304f\u306e\u6761\u4ef6\u691c\u8a0e\u304c\u5fc5\u8981\u3067\u3059\u3002 \u30b9\u30c6\u30c3\u30d7\u6570\u3082\u591a\u3044\u306e\u3067\u3001\u4f55\u3092\u3069\u3046\u6761\u4ef6\u691c\u8a0e\u3059\u308c\u3070\u3088<\/p>\n","protected":false},"author":975,"featured_media":13232,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[50,28],"division":[],"class_list":{"0":"post-13230","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-elisa","9":"tag-experiment","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u30b5\u30f3\u30c9\u30a4\u30c3\u30c1ELISA\u306e\u7cfb\u3092\u81ea\u4f5c\u3067\u69cb\u7bc9\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u6297\u4f53\u30da\u30a2\u306e\u9078\u5b9a\u3001\u691c\u91cf\u7dda\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9078\u5b9a\u3001\u6297\u4f53\u6fc3\u5ea6\u3001\u53cd\u5fdc\u6642\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u2026\u3068\u6570\u591a\u304f\u306e\u6761\u4ef6\u691c\u8a0e\u304c\u5fc5\u8981\u3067\u3059\u3002 \u30b9\u30c6\u30c3\u30d7\u6570\u3082\u591a\u3044\u306e\u3067\u3001\u4f55\u3092\u3069\u3046\u6761\u4ef6\u691c\u8a0e\u3059\u308c\u3070\u3088\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-01-24T05:46:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-10T02:09:43+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png\" \/>\n\t<meta property=\"og:image:width\" content=\"901\" \/>\n\t<meta property=\"og:image:height\" content=\"461\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f\",\"datePublished\":\"2023-01-24T05:46:23+00:00\",\"dateModified\":\"2025-03-10T02:09:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/\"},\"wordCount\":59,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/70b601a63774e30ec04c2257d005d0aa.png\",\"keywords\":[\"ELISA\",\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/\",\"name\":\"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/70b601a63774e30ec04c2257d005d0aa.png\",\"datePublished\":\"2023-01-24T05:46:23+00:00\",\"dateModified\":\"2025-03-10T02:09:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/70b601a63774e30ec04c2257d005d0aa.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/70b601a63774e30ec04c2257d005d0aa.png\",\"width\":901,\"height\":461,\"caption\":\"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/elisa-workshop-bid-ts-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f","og_description":"\u30b5\u30f3\u30c9\u30a4\u30c3\u30c1ELISA\u306e\u7cfb\u3092\u81ea\u4f5c\u3067\u69cb\u7bc9\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u6297\u4f53\u30da\u30a2\u306e\u9078\u5b9a\u3001\u691c\u91cf\u7dda\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u9078\u5b9a\u3001\u6297\u4f53\u6fc3\u5ea6\u3001\u53cd\u5fdc\u6642\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u2026\u3068\u6570\u591a\u304f\u306e\u6761\u4ef6\u691c\u8a0e\u304c\u5fc5\u8981\u3067\u3059\u3002 \u30b9\u30c6\u30c3\u30d7\u6570\u3082\u591a\u3044\u306e\u3067\u3001\u4f55\u3092\u3069\u3046\u6761\u4ef6\u691c\u8a0e\u3059\u308c\u3070\u3088","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-01-24T05:46:23+00:00","article_modified_time":"2025-03-10T02:09:43+00:00","og_image":[{"width":901,"height":461,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f","datePublished":"2023-01-24T05:46:23+00:00","dateModified":"2025-03-10T02:09:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/"},"wordCount":59,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","keywords":["ELISA","\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/","name":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","datePublished":"2023-01-24T05:46:23+00:00","dateModified":"2025-03-10T02:09:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","width":901,"height":461,"caption":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-workshop-bid-ts-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010ELISA\u3084\u3063\u3066\u307f\u305f\u3011Capture Antibody\u306e\u6fc3\u5ea6\u3092\u5909\u3048\u305f\u3089\u3069\u3046\u306a\u308b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":50,"label":"ELISA"},{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png",760,389,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":50,"name":"ELISA","slug":"elisa","term_group":0,"term_taxonomy_id":50,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":13230,"position":0},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25121,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-nucleic-acid-purification-bid-ts-mbr-26017\/","url_meta":{"origin":13230,"position":1},"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u30444PL\u306e\u57fa\u672c\uff1a4\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac","author":"LATB Staff","date":"2026\u5e745\u67087\u65e5","format":false,"excerpt":"ELISA\u306e\u691c\u91cf\u7dda\u3084\u7528\u91cf\u53cd\u5fdc\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3068\u304d\u306b\u30014\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\uff084PL\uff09\u30e2\u30c7\u30eb\u3092\u4f7f\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":13230,"position":2},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25170,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody-purification-vaccine-bpg-26018\/","url_meta":{"origin":13230,"position":3},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\u7cbe\u88fd\u306e\u57fa\u790e\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u6a39\u8102\u9078\u629e","author":"LatB Staff","date":"2026\u5e745\u670819\u65e5","format":false,"excerpt":"\u5c0e\u5165 \u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\uff08bispecific antibody\u3001\u4ee5\u4e0bBsAb\uff09\u306f\u30012\u3064\u306e\u7570\u306a\u308b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":13230,"position":4},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":13230,"position":5},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/70b601a63774e30ec04c2257d005d0aa.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13230"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13230\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13232"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13230"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13230"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13230"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}