{"id":13241,"date":"2023-02-01T13:27:19","date_gmt":"2023-02-01T04:27:19","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13241"},"modified":"2025-04-15T16:10:20","modified_gmt":"2025-04-15T07:10:20","slug":"training-ts-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/","title":{"rendered":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e"},"content":{"rendered":"<p>\u5f53\u793e\u3067\u306f\u8b1b\u7fa9\u3068\u30e9\u30dc\u5b9f\u7fd2\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u5b9f\u8df5\u7684\u306a<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u591a\u6570\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u306b\u53d6\u308a\u7d44\u3093\u3060\u3053\u3068\u304c\u306a\u3044\u65b0\u3057\u3044\u5b9f\u9a13\u7cfb\u3092\u59cb\u3081\u305f\u3044\u65b9\u3084\u3001\u57fa\u790e\u304b\u3089\u5b66\u3073\u306a\u304a\u3057\u305f\u3044\u65b9\u3001\u65b0\u4eba\u7814\u4fee\u306a\u3069\u306b\u3082\u304a\u3059\u3059\u3081\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u30b3\u30fc\u30b9\u306e\u4e00\u4f8b\u3068\u3057\u3066\u3001\u4e0b\u8a18\u306e\u3088\u3046\u306a\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u5206\u5b50\u751f\u7269\u5b66\u95a2\u9023\uff1aRNA\u62bd\u51fa\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3001microRNA\u3001\u30b2\u30ce\u30e0\u7de8\u96c6\u3001\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3001\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b9<br \/>\n\u7d30\u80de\u95a2\u9023\uff1a\u7d30\u80de\u57f9\u990a\u3001\u86cd\u5149\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3001\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc<br \/>\n\u30bf\u30f3\u30d1\u30af\u8cea\u95a2\u9023\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\u3001ELISA<br \/>\nPCR\u95a2\u9023\uff1a\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\uff083\u30b3\u30fc\u30b9\uff09\u3001\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\uff082\u30b3\u30fc\u30b9\uff09<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u3001\u3055\u307e\u3056\u307e\u306a\u5b9f\u9a13\u306b\u3064\u3044\u3066\u306e\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30b3\u30fc\u30b9\u3092\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u306a\u304b\u3067\u3082\u3001PCR\u306b\u95a2\u3059\u308b\u3082\u306e\u3060\u3051\u3067\u5408\u8a085\u30b3\u30fc\u30b9\u3082\u5b58\u5728\u3057\u3001\u30b3\u30fc\u30b9\u9078\u629e\u306b\u8ff7\u308f\u308c\u308b\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002PCR\u95a2\u9023\u30b3\u30fc\u30b9\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3068\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u306b\u5927\u5225\u3067\u304d\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u7279\u9577\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><b>\u3010\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3011<\/b><br \/>\n\u86cd\u5149\u5f37\u5ea6\u3092\u6307\u6a19\u3068\u3057\u3066DNA\u306e\u5897\u5e45\u7a0b\u5ea6\u3092\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u306b\u691c\u51fa\u3059\u308b\u624b\u6cd5\u3067\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3084\u5fae\u751f\u7269\u30fb\u30a6\u30a4\u30eb\u30b9\u306e\u691c\u51fa\u306a\u3069\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13249\" style=\"width: 576px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13249\" class=\"wp-image-13249 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png\" alt=\"\" width=\"566\" height=\"292\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png 566w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1-300x155.png 300w\" sizes=\"auto, (max-width: 566px) 100vw, 566px\" \/><p id=\"caption-attachment-13249\" class=\"wp-caption-text\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7d50\u679c\u4f8b<\/p><\/div>\n<p><b>\u3010\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u3011<\/b><br \/>\nDNA\u3092\u5897\u5e45\u3055\u305b\u305f\u5f8c\u3001\u6700\u5f8c\u306b\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306a\u3069\u3067PCR\u7523\u7269\u306e\u6709\u7121\u3084\u9577\u3055\u3092\u78ba\u8a8d\u3059\u308b\u624b\u6cd5\u3067\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u524d\u51e6\u7406\u306a\u3069\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13250\" style=\"width: 620px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13250\" class=\"size-full wp-image-13250\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/2e0dd6bc2872e77045a7e0fb241df7f0.png\" alt=\"\" width=\"610\" height=\"268\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/2e0dd6bc2872e77045a7e0fb241df7f0.png 610w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/2e0dd6bc2872e77045a7e0fb241df7f0-300x132.png 300w\" sizes=\"auto, (max-width: 610px) 100vw, 610px\" \/><p id=\"caption-attachment-13250\" class=\"wp-caption-text\">\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u306e\u7d50\u679c\u4f8b<\/p><\/div>\n<p>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u304a\u5ba2\u3055\u307e\u306b\u3068\u3063\u3066\u306e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u9078\u629e\u306e\u305f\u3081\u306b\u30ac\u30a4\u30c9\u3092\u3055\u305b\u3066\u3044\u305f\u3060\u304d\u307e\u3059\u3002<\/p>\n<h2>PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u9078\u3073\u65b9<\/h2>\n<p>\u307e\u305a\u30015\u7a2e\u985e\u306ePCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306e\u30d5\u30ed\u30fc\u30c1\u30e3\u30fc\u30c8\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13251\" style=\"width: 943px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13251\" class=\"size-full wp-image-13251\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/626202e07cde05e73c95ed96a3735b64.png\" alt=\"\" width=\"933\" height=\"360\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/626202e07cde05e73c95ed96a3735b64.png 933w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/626202e07cde05e73c95ed96a3735b64-300x116.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/626202e07cde05e73c95ed96a3735b64-768x296.png 768w\" sizes=\"auto, (max-width: 933px) 100vw, 933px\" \/><p id=\"caption-attachment-13251\" class=\"wp-caption-text\">PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u9078\u629e\u30c1\u30e3\u30fc\u30c8<\/p><\/div>\n<p>\u2460 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/realtime-pcr-pipette-operation-qualitative-test.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0 \uff5e\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u7df4\u7fd2\u304b\u3089\u306e\u8d85\u57fa\u672c\u7de8\uff5e<\/a><br \/>\n\u2461 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/pcr-basic.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u57fa\u790e\u304b\u3089\u308f\u304b\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0I \uff5e\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u76f8\u5bfe\u5b9a\u91cf\u7de8\uff5e<\/a><br \/>\n\u2462 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/rpcr2.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u57fa\u790e\u304b\u3089\u308f\u304b\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0II \uff5e\u5fae\u751f\u7269\u30fb\u30a6\u30a4\u30eb\u30b9\u306e\u7d76\u5bfe\u5b9a\u91cf\u7de8\uff5e<\/a><br \/>\n\u2463 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/bio-experiment.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u30d0\u30a4\u30aa\u5b9f\u9a13 \uff5e\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u304b\u3089PCR\u307e\u3067\uff5e<\/a><br \/>\n\u2464 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">PCR\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a><\/p>\n<p>\u30b3\u30fc\u30b9\u540d\u304c\u4f3c\u3066\u3044\u308b\u3053\u3068\u3082\u3042\u308a\u3001\u5c11\u3057\u9078\u629e\u3057\u3065\u3089\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u6b21\u306b\u3001\u305d\u308c\u305e\u308c\u306e\u30b3\u30fc\u30b9\u306e\u7279\u9577\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u5404\u30b3\u30fc\u30b9\u306e\u7279\u9577\u306e\u3054\u7d39\u4ecb<\/h2>\n<p><b>\u2460 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/realtime-pcr-pipette-operation-qualitative-test.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0 \uff5e\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u7df4\u7fd2\u304b\u3089\u306e\u8d85\u57fa\u672c\u7de8\uff5e<\/a><\/b><br \/>\n\u3010\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3011<br \/>\n\u30fb\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u304c\u521d\u3081\u3066\u306e\u65b9\u3084\u3001\u6163\u308c\u3066\u3044\u306a\u3044\u65b9<br \/>\n\u30fb\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u3053\u308c\u304b\u3089\u5b66\u3073\u305f\u3044\u3068\u3044\u3046\u65b9<br \/>\n\u30fb\u57fa\u672c\u7684\u306a\u624b\u6280\u304b\u3089\u8eab\u306b\u7740\u3051\u305f\u3044\u65b9<\/p>\n<p>\u3010\u5b9f\u7fd2\u5185\u5bb9\u3011<br \/>\n\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u306e\u7df4\u7fd2\u3084\u53cd\u5fdc\u6db2\u8abf\u88fd\u306e\u57fa\u672c\u304b\u3089\u59cb\u307e\u308b\u306e\u3067\u3001\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u304c\u521d\u3081\u3066\u306e\u65b9\u3067\u3082\u5b89\u5fc3\u3057\u3066\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\u3002\u5b9f\u969b\u306b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3067DNA\u304c\u5897\u5e45\u3059\u308b\u304b\u3069\u3046\u304b\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u91cf\u306b\u3088\u3063\u3066\u5897\u5e45\u66f2\u7dda\u304c\u3069\u306e\u3088\u3046\u306b\u7570\u306a\u308b\u304b\u3092\u78ba\u8a8d\u3057\u3066\u3044\u305f\u3060\u304d\u307e\u3059\u3002<\/p>\n<p><b>\u2461 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/pcr-basic.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u57fa\u790e\u304b\u3089\u308f\u304b\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0I \uff5e\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u76f8\u5bfe\u5b9a\u91cf\u7de8\uff5e<\/a><\/b><br \/>\n\u3010\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3011<br \/>\n\u30fb\u76f8\u5bfe\u5b9a\u91cf\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u65b9<br \/>\n\u30fb\u76f8\u5bfe\u5b9a\u91cf\u306e\u5b9f\u9a13\u7cfb\u306b\u4e0d\u5b89\u304c\u3042\u308b\u65b9<br \/>\n\u30fb\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9<\/p>\n<p>\u3010\u5b9f\u7fd2\u5185\u5bb9\u3011<br \/>\n2\u3064\u306e\u30d2\u30c8\u57f9\u990a\u7d30\u80de\u304b\u3089\u8abf\u88fd\u3057\u305fcDNA\u3092\u30b5\u30f3\u30d7\u30eb\u3068\u3057\u3066\u3001\u0394\u0394C<sub>T<\/sub>\u6cd5\u3068\u691c\u91cf\u7dda\u6cd5\u306b\u3088\u308a\u3001\u907a\u4f1d\u5b50\u767a\u73fe\u306e\u76f8\u5bfe\u5b9a\u91cf\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002\u540c\u3058\u30b5\u30f3\u30d7\u30eb\u30672\u3064\u306e\u7570\u306a\u308b\u65b9\u6cd5\u3092\u304a\u8a66\u3057\u3044\u305f\u3060\u304f\u306e\u3067\u3001\u305d\u308c\u305e\u308c\u306e\u65b9\u6cd5\u306e\u7279\u5fb4\u3092\u4f53\u611f\u3057\u3064\u3064\u3054\u7406\u89e3\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><b>\u2462 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/rpcr2.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u57fa\u790e\u304b\u3089\u308f\u304b\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0II \uff5e\u5fae\u751f\u7269\u30fb\u30a6\u30a4\u30eb\u30b9\u306e\u7d76\u5bfe\u5b9a\u91cf\u7de8\uff5e<\/a><\/b><br \/>\n\u3010\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3011<br \/>\n\u30fb\u7d76\u5bfe\u5b9a\u91cf\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u65b9<br \/>\n\u30fb\u30b3\u30d4\u30fc\u6570\u5b9a\u91cf\u306e\u624b\u6280\u306b\u4e0d\u5b89\u304c\u3042\u308b\u65b9<br \/>\n\u30fb\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9<\/p>\n<p>\u3010\u5b9f\u7fd2\u5185\u5bb9\u3011<br \/>\nRNA\u30a6\u30a4\u30eb\u30b9\u3092\u60f3\u5b9a\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u3092\u4f7f\u7528\u3057\u3001\u691c\u91cf\u7dda\u6cd5\u306b\u3088\u308b\u7d76\u5bfe\u5b9a\u91cf\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002RNA\u306f\u305d\u306e\u307e\u307ePCR\u3067\u304d\u306a\u3044\u306e\u3067\u9006\u8ee2\u5199\u53cd\u5fdc\u304b\u3089\u59cb\u3081\u3001\u30b3\u30d4\u30fc\u6570\u65e2\u77e5\u30b5\u30f3\u30d7\u30eb\u306e\u6bb5\u968e\u5e0c\u91c8\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3088\u308b\u30b3\u30d4\u30fc\u6570\u7b97\u51fa\u3092\u5b9f\u65bd\u3057\u3066\u3044\u305f\u3060\u304d\u307e\u3059\u3002<\/p>\n<p><b>\u2463 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/bio-experiment.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u30d0\u30a4\u30aa\u5b9f\u9a13 \uff5e\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u304b\u3089PCR\u307e\u3067\uff5e<\/a><\/b><br \/>\n\u3010\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3011<br \/>\n\u30fb\u30d0\u30a4\u30aa\u5b9f\u9a13\u3092\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u306e\u3067\u57fa\u790e\u304b\u3089\u5b66\u3073\u305f\u3044\u65b9<br \/>\n\u30fb\u5468\u308a\u306b\u30d0\u30a4\u30aa\u5b9f\u9a13\u3092\u3057\u3066\u3044\u308b\u4eba\u306f\u3044\u308b\u304c\u3001\u3068\u3066\u3082\u5fd9\u3057\u305d\u3046\u306a\u306e\u3067\u6c17\u8efd\u306b\u6559\u308f\u308a\u306b\u304f\u3044<br \/>\n\u30fbPCR\u5b9f\u9a13\u3067\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u51fa\u3057\u305f\u3044\u65b9<\/p>\n<p>\u3010\u5b9f\u7fd2\u5185\u5bb9\u3011<br \/>\n\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u306e\u7df4\u7fd2\u3084\u53cd\u5fdc\u6db2\u8abf\u88fd\u306e\u57fa\u672c\u304b\u3089\u59cb\u307e\u308b\u306e\u3067\u3001\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u304c\u521d\u3081\u3066\u306e\u65b9\u3067\u3082\u5b89\u5fc3\u3057\u3066\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\u3002\u4e00\u822c\u7684\u306a\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u81ea\u4f5c\u3057\u3066\u3001DNA\u306e\u5897\u5e45\u3092\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u78ba\u8a8d\u3057\u3066\u3044\u305f\u3060\u304d\u307e\u3059\u3002<\/p>\n<p><b>\u2464 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/pcr.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">PCR\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a><\/b><br \/>\n\u3010\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3011<br \/>\n\u30fbPCR\u5b9f\u9a13\u3092\u3057\u3066\u3044\u3066\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9<br \/>\n\u30fb\u30d7\u30e9\u30a4\u30de\u30fc\u8a2d\u8a08\u306e\u65b9\u6cd5\u3092\u7fd2\u5f97\u3057\u305f\u3044\u65b9<br \/>\n\u30fbPCR\u5b9f\u9a13\u306e\u53cd\u5fdc\u7cfb\u69cb\u7bc9\u306b\u304a\u60a9\u307f\u306e\u65b9<\/p>\n<p>\u3010\u5b9f\u7fd2\u5185\u5bb9\u3011<br \/>\n\u516c\u5171\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3084\u30d5\u30ea\u30fc\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u5229\u7528\u3057\u3064\u3064\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u8a2d\u8a08\u3059\u308b\u65b9\u6cd5\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u30a8\u30f3\u30c9\u30dd\u30a4\u30f3\u30c8PCR\u304b\u3089\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u306e\u6700\u9069\u5316\u306a\u3069\u3001PCR\u53cd\u5fdc\u3092\u8907\u6570\u5b9f\u65bd\u3057\u307e\u3059\u3002PCR\u7523\u7269\u306f\u5f53\u793e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/nucleic-acid-gel-electrophoresis\/e-gel-electrophoresis-system\/e-gel-pre-cast-agarose-gels.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 E-Gel\u2122\u30d7\u30ec\u30ad\u30e3\u30b9\u30c8\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb<\/a>\u3092\u4f7f\u7528\u3057\u3066\u78ba\u8a8d\u3057\u3066\u3044\u305f\u3060\u304d\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u304b\u3002<br \/>\n\u3053\u306e\u30d6\u30ed\u30b0\u304c\u3001PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u629e\u306b\u304a\u5f79\u306b\u7acb\u3066\u3070\u3046\u308c\u3057\u304f\u601d\u3044\u307e\u3059\u3002\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u305f\u30b3\u30fc\u30b9\u306e\u4ed6\u306b\u3082\u3001\u304a\u5ba2\u3055\u307e\u3054\u8981\u671b\u306e\u5185\u5bb9\u3067\u5b9f\u65bd\u3059\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/private-group-training.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ab\u30b9\u30bf\u30e0\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3082\u53ef\u80fd\u3067\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/rna_cdna.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">RNA\u62bd\u51fa<\/a>\u306a\u3069\u4ed6\u306e\u30b3\u30fc\u30b9\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u308a\u3001\u3054\u81ea\u8eab\u306e\u30b5\u30f3\u30d7\u30eb\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u4f7f\u7528\u3057\u305f\u308a\u3001\u304a\u5ba2\u3055\u307e\u306e\u72b6\u6cc1\u306b\u5408\u308f\u305b\u305f\u5185\u5bb9\u3092\u3054\u63d0\u4f9b\u3067\u304d\u307e\u3059\u3002\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306f\u5f53\u793e\u4e09\u7530\u30e9\u30dc\uff08\u6771\u4eac\u90fd\u6e2f\u533a\u829d\u6d66\u56db\u4e01\u76ee2\u756a8\u53f7\u3000\u4f4f\u53cb\u4e0d\u52d5\u7523\u4e09\u7530\u30c4\u30a4\u30f3\u30d3\u30eb\u6771\u9928\uff09\u306b\u3066\u5b9f\u65bd\u3057\u3066\u3044\u307e\u3059\u3002\u6771\u4eac\u304b\u3089\u9060\u65b9\u306e\u304a\u5ba2\u3055\u307e\u3084\u3001\u5fd9\u3057\u304f\u3066\u307e\u3068\u307e\u3063\u305f\u6642\u9593\u304c\u53d6\u308c\u306a\u3044\u65b9\u306b\u306f\u3001\u3054\u81ea\u8eab\u3067\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u7df4\u7fd2\u3067\u304d\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/self-training-kit.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30bb\u30eb\u30d5\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30ad\u30c3\u30c8<\/a>\u3082\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u57f7\u7b46\u6642\u70b9(2023\u5e742\u6708)\u3067\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/self-training-kit\/real-time-pcr-relative-quantification.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u76f8\u5bfe\u5b9a\u91cf<\/a>\u3068<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/self-training-kit\/real-time-pcr-absolute-quantification.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u7d76\u5bfe\u5b9a\u91cf<\/a>\u306e2\u3064\u306e\u30b3\u30fc\u30b9\u3092\u63d0\u4f9b\u3057\u3066\u304a\u308a\u3001\u5f53\u793e\u30b9\u30bf\u30c3\u30d5\u306b\u3088\u308b\u8b1b\u7fa9\u30fb\u5b9f\u7fd2\u306e\u8aac\u660e\u304c\u542b\u307e\u308c\u308b\u52d5\u753b\u4ed8\u304d\u306e\u30d7\u30e9\u30f3\u3084\u3001\u5b9f\u9a13\u30c7\u30fc\u30bf\u3092\u78ba\u8a8d\u3057\u30ec\u30dd\u30fc\u30c8\u3092\u304a\u8fd4\u3057\u3059\u308b\u30d7\u30e9\u30f3\u3001\u30aa\u30f3\u30e9\u30a4\u30f3\u3067\u4e00\u7dd2\u306b\u5b9f\u7fd2\u3092\u9032\u3081\u308b\u30d7\u30e9\u30f3\u306a\u3069\u304b\u3089\u304a\u9078\u3073\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><b>\u4eca\u56de\u306e\u8a18\u4e8b\u306b\u95a2\u9023\u3059\u308b\u30da\u30fc\u30b8<b><br \/>\n<\/b><\/b><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/cloning-learning-center\/invitrogen-school-of-molecular-biology\/pcr-education\/pcr-reagents-enzymes.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">PCR\u8a66\u85ac\u3068\u9175\u7d20\u306e\u57fa\u790e\u77e5\u8b58<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-learning-center.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0 PCR\uff08qPCR\uff09\u30e9\u30fc\u30cb\u30f3\u30b0\u30bb\u30f3\u30bf\u30fc<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/mol-bio-school.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_training_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u5206\u5b50\u751f\u7269\u5b66\u6559\u5ba4PDF\u7248 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f53\u793e\u3067\u306f\u8b1b\u7fa9\u3068\u30e9\u30dc\u5b9f\u7fd2\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u5b9f\u8df5\u7684\u306a\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u591a\u6570\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u306b\u53d6\u308a\u7d44\u3093\u3060\u3053\u3068\u304c\u306a\u3044\u65b0\u3057\u3044\u5b9f\u9a13\u7cfb\u3092\u59cb\u3081\u305f\u3044\u65b9\u3084\u3001\u57fa\u790e\u304b\u3089\u5b66\u3073\u306a\u304a\u3057\u305f\u3044\u65b9\u3001\u65b0\u4eba\u7814\u4fee\u306a\u3069\u306b\u3082\u304a\u3059\u3059\u3081\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u30b3\u30fc\u30b9<\/p>\n","protected":false},"author":975,"featured_media":13249,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[9,7],"division":[],"class_list":["post-13241","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pcr","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e\" \/>\n<meta property=\"og:description\" content=\"\u5f53\u793e\u3067\u306f\u8b1b\u7fa9\u3068\u30e9\u30dc\u5b9f\u7fd2\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u5b9f\u8df5\u7684\u306a\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u591a\u6570\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u306b\u53d6\u308a\u7d44\u3093\u3060\u3053\u3068\u304c\u306a\u3044\u65b0\u3057\u3044\u5b9f\u9a13\u7cfb\u3092\u59cb\u3081\u305f\u3044\u65b9\u3084\u3001\u57fa\u790e\u304b\u3089\u5b66\u3073\u306a\u304a\u3057\u305f\u3044\u65b9\u3001\u65b0\u4eba\u7814\u4fee\u306a\u3069\u306b\u3082\u304a\u3059\u3059\u3081\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u30b3\u30fc\u30b9\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-01T04:27:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T07:10:20+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"566\" \/>\n\t<meta property=\"og:image:height\" content=\"292\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e\",\"datePublished\":\"2023-02-01T04:27:19+00:00\",\"dateModified\":\"2025-04-15T07:10:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/\"},\"wordCount\":87,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/1bd6462d2fabca6002e1e0d3b7662984-1.png\",\"keywords\":[\"PCR\",\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/\",\"name\":\"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/1bd6462d2fabca6002e1e0d3b7662984-1.png\",\"datePublished\":\"2023-02-01T04:27:19+00:00\",\"dateModified\":\"2025-04-15T07:10:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/1bd6462d2fabca6002e1e0d3b7662984-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/01\\\/1bd6462d2fabca6002e1e0d3b7662984-1.png\",\"width\":566,\"height\":292},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/training-ts-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/","og_locale":"ja_JP","og_type":"article","og_title":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e","og_description":"\u5f53\u793e\u3067\u306f\u8b1b\u7fa9\u3068\u30e9\u30dc\u5b9f\u7fd2\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u5b9f\u8df5\u7684\u306a\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u591a\u6570\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u306b\u53d6\u308a\u7d44\u3093\u3060\u3053\u3068\u304c\u306a\u3044\u65b0\u3057\u3044\u5b9f\u9a13\u7cfb\u3092\u59cb\u3081\u305f\u3044\u65b9\u3084\u3001\u57fa\u790e\u304b\u3089\u5b66\u3073\u306a\u304a\u3057\u305f\u3044\u65b9\u3001\u65b0\u4eba\u7814\u4fee\u306a\u3069\u306b\u3082\u304a\u3059\u3059\u3081\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u30b3\u30fc\u30b9","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-02-01T04:27:19+00:00","article_modified_time":"2025-04-15T07:10:20+00:00","og_image":[{"width":566,"height":292,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e","datePublished":"2023-02-01T04:27:19+00:00","dateModified":"2025-04-15T07:10:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/"},"wordCount":87,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","keywords":["PCR","\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/","name":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","datePublished":"2023-02-01T04:27:19+00:00","dateModified":"2025-04-15T07:10:20+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","width":566,"height":292},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/training-ts-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"PCR\u7cfb\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u30b3\u30fc\u30b9\u9078\u3073\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f\uff5e\u6700\u9069\u306a\u30b3\u30fc\u30b9\u3092\u9078\u629e\u3057\u3066\u3044\u305f\u3060\u304f\u305f\u3081\u306b\uff5e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":9,"label":"PCR"},{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png",566,292,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":9,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":9,"taxonomy":"post_tag","description":"","parent":0,"count":29,"filter":"raw","meta":[]},{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":13241,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":13241,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":13241,"position":2},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":13241,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":13241,"position":4},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":13241,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/01\/1bd6462d2fabca6002e1e0d3b7662984-1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13241"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13241\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13249"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13241"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13241"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13241"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}