{"id":13496,"date":"2023-03-13T17:41:04","date_gmt":"2023-03-13T08:41:04","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13496"},"modified":"2023-11-15T09:40:27","modified_gmt":"2023-11-15T00:40:27","slug":"dynadrive_bpg_1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/","title":{"rendered":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577"},"content":{"rendered":"<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/bioproduction\/single-use-bioprocessing\/single-use-equipment\/single-use-bioreactors\/dynadrive-sub.html?CID=dynadrive_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 DynaDrive\u2122 \u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09<\/a>\u306f\u300150 L\u304b\u30895,000 L\u307e\u3067\u5e45\u5e83\u3044\u6db2\u91cf\u3067\u52d5\u7269\u7d30\u80de\u3092\u57f9\u990a\u3067\u304d\u308b\u5f53\u793e\u306e\u6700\u65b0\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3059\u3002<br \/>\n\u76f4\u65b9\u4f53\u306e\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u30e6\u30cb\u30fc\u30af\u306a\u30a4\u30f3\u30da\u30e9\u5f62\u72b6\u3092\u63a1\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5f93\u6765\u54c1\u3068\u6bd4\u3079\u3066\u652a\u62cc\u52b9\u7387\u304c\u5411\u4e0a\u3057\u3001\u3088\u308a\u5c11\u91cf\u304b\u3089\u57f9\u990a\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u57f9\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u80fd\u529b\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u3067\u3001\u30d1\u30fc\u30d5\u30e5\u30fc\u30b8\u30e7\u30f3\u57f9\u990a\u3084\u9ad8\u5bc6\u5ea6\u57f9\u990a\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u308b\u6027\u80fd\u3092\u4ed8\u4e0e\u3057\u3001\u6c4e\u7528\u6027\u306e\u9ad8\u3044\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306fDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09\u306e3\u3064\u306e\u7279\u9577\u3092\u305d\u308c\u305e\u308c\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p><iframe loading=\"lazy\" title=\"HyPerforma DynaDrive S.U.B.- Novel design and features to accommodate modern cell culture processes\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/inUJ3VctYTA?start=5&#038;feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/p>\n<p>\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/p>\n<ul>\n<li>\u5e45\u5e83\u3044\u6db2\u91cf\u3067\u52d5\u7269\u7d30\u80de\u3092\u57f9\u990a\u3067\u304d\u308b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3092\u63a2\u3057\u3066\u3044\u308b<\/li>\n<li>\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30c3\u30b0\u3067\u3042\u308b\u30d0\u30a4\u30aa\u30d7\u30ed\u30bb\u30b9\u30b3\u30f3\u30c6\u30ca\uff08BPC\uff09\u306e\u53d6\u308a\u4ed8\u3051\u3092\u30b9\u30e0\u30fc\u30ba\u306b\u884c\u3044\u305f\u3044<\/li>\n<li>\u30d5\u30a7\u30c3\u30c9\u30d0\u30c3\u30c1\u57f9\u990a\u30fb\u30d1\u30fc\u30d5\u30e5\u30fc\u30b8\u30e7\u30f3\u57f9\u990a\u4e21\u65b9\u306b\u9069\u3057\u305f\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3092\u5c0e\u5165\u3057\u305f\u3044<\/li>\n<\/ul>\n<h2>\u7279\u95771\uff1a\u9ad8\u3044\u30bf\u30fc\u30f3\u30c0\u30a6\u30f3\u6bd4\u3068\u5c11\u306a\u3044\u6a5f\u5668\u53f0\u6570\u3067\u30aa\u30da\u30ec\u30fc\u30b7\u30e7\u30f3\u30b3\u30b9\u30c8\u3068\u6d88\u8017\u54c1\uff08\u5ec3\u68c4\u7269\uff09\u306e\u6e1b\u5c11\u306b\u5bc4\u4e0e\u3057\u30015,000 L\u307e\u3067\u306e\u57f9\u990a\u3092\u30b5\u30dd\u30fc\u30c8<\/h2>\n<div id=\"attachment_13498\" style=\"width: 1290px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13498\" class=\"wp-image-13498 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg 1280w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><p id=\"caption-attachment-13498\" class=\"wp-caption-text\">\u30b9\u30e9\u30a4\u30c9\u2460<\/p><\/div>\n<p>DynaDrive S.U.B. \u306f50L, 500L, 3,000L, 5,000L\u306e4\u30b5\u30a4\u30ba\u3067\u88fd\u54c1\u5c55\u958b\u3057\u3066\u3044\u307e\u3059\u3002\u5f93\u6765\u578b\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u6bd4\u3079\u3001\u9ad8\u3044\u30bf\u30fc\u30f3\u30c0\u30a6\u30f3\u6bd4\uff08\u904b\u8ee2\u5bb9\u91cf\u6bd4\uff09\u3092\u6709\u3057\u3066\u304a\u308a\u300150 L\u3067\u306f5 L\u304b\u3089\u3001500 L\u3067\u306f25 L\u304b\u3089\u30013,000 L\u30685,000 L\u306f250 L\u304b\u3089\u57f9\u990a\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u30b9\u30e9\u30a4\u30c9\u2460\u306b\u3001\u5f53\u793e\u306e\u5f93\u6765\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fcHyPerforma S.U.B.\u3092\u4f7f\u7528\u3057\u3066\u6700\u5927\u30b9\u30b1\u30fc\u30eb\u3067\u3042\u308b2,000 L\u307e\u3067\u57f9\u990a\u3057\u305f\u5834\u5408\u3068\u3001DynaDrive S.U.B.\u306b\u30665,000 L\u307e\u3067\u62e1\u5927\u57f9\u990a\u3057\u305f\u5834\u5408\u306e\u5de5\u7a0b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5f93\u6765\u306e\u5834\u5408\u30012,000 L\u307e\u3067\u306e\u62e1\u5927\u57f9\u990a\u3092\u5b9f\u65bd\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u307e\u305aworking cell bank\u304b\u3089\u7d30\u80de\u3092\u8d77\u3053\u3057\u3001\u30d5\u30e9\u30b9\u30b3\u57f9\u990a\u3001\u30ed\u30c3\u30ab\u30fc\u57f9\u990a\u3092\u7d4c\u306650 L\u306e\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u79fb\u308a\u3001500 L\u30012,000 L\u3078\u3001\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306f10:1\u4ee5\u4e0a\u306e\u30bf\u30fc\u30f3\u30c0\u30a6\u30f3\u6bd4\u3092\u6709\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u30d5\u30e9\u30b9\u30b3\u57f9\u990a\u304b\u3089\u76f4\u63a550 L\u306eDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u79fb\u884c\u3057\u3001\u6700\u5c0f5 L\u304b\u3089\u57f9\u990a\u3092\u958b\u59cb\u3057\u3001\u57f9\u5730\u3092\u3055\u3089\u306b\u8ffd\u52a0\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u540c\u4e00\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u5185\u3067\u62e1\u5927\u57f9\u990a\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u300250 L\u3067\u57f9\u990a\u5f8c\u3001\u540c\u69d8\u306b5,000 L\u306eDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u3066\u3001\u6700\u5c0f250 L\u304b\u3089n-1\u3082\u3057\u304f\u306fn-2\u304b\u3089\u306e\u62e1\u5927\u57f9\u990a\u304a\u3088\u3073\u751f\u7523\u57f9\u990a\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u3053\u308c\u306b\u3088\u308a\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/bioproduction\/single-use-bioprocessing\/flexible-containment\/standard-bioprocess-containers.html?CID=dynadrive_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d0\u30a4\u30aa\u30d7\u30ed\u30bb\u30b9\u30b3\u30f3\u30c6\u30ca\uff08BPC\uff09\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30c3\u30b0<\/a>\u3084<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/bioproduction\/single-use-bioprocessing\/flexible-containment\/fluid-transfer-solutions.html?CID=dynadrive_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c1\u30e5\u30fc\u30d3\u30f3\u30b0<\/a>\u3068\u3044\u3063\u305f\u6d88\u8017\u54c1\uff08\u5ec3\u68c4\u7269\uff09\u306e\u524a\u6e1b\u3068\u3001\u62e1\u5927\u57f9\u990a\u306e\u5de5\u7a0b\u77ed\u7e2e\u306b\u3088\u308b\u52b4\u529b\u306e\u524a\u6e1b\u306b\u3064\u306a\u3052\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<h2>\u7279\u95772\uff1a\u30b7\u30f3\u30d7\u30eb\u306a\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0\uff1aBPC\u306e\u53d6\u308a\u4ed8\u3051\u304c\u5bb9\u6613\u306b\u306a\u308a\u3001\u9ad8\u6240\u4f5c\u696d\u3082\u4e0d\u8981\u306b<\/h2>\n<p>DynaDrive S.U.B. \u306e\u30cf\u30fc\u30c9\u30a6\u30a8\u30a2\u306e\u7279\u9577\u3092\u4e0b\u56f3\u306b\u793a\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13499\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/b6d8e0fcc8b053f0bafe6912d1ea6f38.jpg\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/b6d8e0fcc8b053f0bafe6912d1ea6f38.jpg 1280w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/b6d8e0fcc8b053f0bafe6912d1ea6f38-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/b6d8e0fcc8b053f0bafe6912d1ea6f38-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/b6d8e0fcc8b053f0bafe6912d1ea6f38-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><br \/>\n\u203b\u4e0a\u8a18\u30b9\u30e9\u30a4\u30c9\u306f50 L\u306eDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3059\u304c\u3001\u3044\u305a\u308c\u306e\u30b5\u30a4\u30ba\u3082\u540c\u7b49\u306e\u7279\u9577\u3092\u6709\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306f\u30d9\u30c3\u30bb\u30eb\u524d\u65b9\u306e\u6249\u304c\u5b8c\u5168\u306b\u958b\u304f\u3088\u3046\u306b\u306a\u3063\u3066\u304a\u308a\u3001BPC\u306e\u53d6\u308a\u4ed8\u3051\u304c\u5bb9\u6613\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u9ad8\u3055\u306e\u3042\u308b3,000 L\u30015,000 L\u306b\u3064\u3044\u3066\u306f\u30ea\u30d5\u30c8\u6a5f\u69cb\u3092\u63a1\u7528\u3057\u3001BPC\u3084\u30c1\u30e5\u30fc\u30d6\u985e\u306e\u53d6\u308a\u4ed8\u3051\u306b\u3064\u3044\u3066\u3001\u9ad8\u6240\u3067\u306e\u4f5c\u696d\u304c\u4e0d\u8981\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306bDO\u30bb\u30f3\u30b5\u30fc\u3084pH\u30bb\u30f3\u30b5\u30fc\u3092\u53d6\u308a\u4ed8\u3051\u308b\u30d7\u30ed\u30fc\u30d6\u30dd\u30fc\u30c8\u306f\u30ea\u30a2\u30af\u30bf\u30fc\u306e\u4e0b\u306e\u65b9\u306b\u3042\u308b\u305f\u3081\u3001\u53d6\u308a\u4ed8\u3051\u304c\u5bb9\u6613\u3067\u3059\u3002\u307e\u305f\u3001\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u306eDO\u30bb\u30f3\u30b5\u30fc\u3001pH\u30bb\u30f3\u30b5\u30fc\u3082\u4f7f\u7528\u53ef\u80fd\u3067\u3059\u3002BPC\u306e\u53d6\u308a\u4ed8\u3051\u306b\u3064\u3044\u3066\u306f\u3001\u4e0a\u90e8\u306e\u30e2\u30fc\u30bf\u30fc\u63a5\u7d9a\u90e8\u5206\u306bBPC\u306e\u64b9\u62cc\u7ffc\uff08\u30a4\u30f3\u30da\u30e9\uff09\u306e\u8ef8\u3092\u56fa\u5b9a\u3057\u3066\u3044\u305f\u3060\u304d\u3001\u30d0\u30c3\u30b0\u306e\u56db\u9685\u3092\u56fa\u5b9a\u3059\u308b\u3060\u3051\u3067\u5b8c\u4e86\u3057\u307e\u3059\u3002<\/p>\n<h2>\u7279\u95773\uff1a\u9ad8\u52b9\u7387\u3092\u5b9f\u73fe\u3059\u308b\u76f4\u65b9\u4f53\u30c7\u30b6\u30a4\u30f3\u3067\u9ad8\u3044\u9178\u7d20\u8981\u6c42\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u308b\u652a\u62cc\u6027\u80fd\u304a\u3088\u3073\u652a\u62cc\u52b9\u7387\u3092\u517c\u306d\u5099\u3048\u300150 L\u304b\u30895,000 L\u307e\u3067\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u304c\u53ef\u80fd\u306b<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13500\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17e60eb6a550ad6f07110e2e90a8e31.jpg\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17e60eb6a550ad6f07110e2e90a8e31.jpg 1280w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17e60eb6a550ad6f07110e2e90a8e31-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17e60eb6a550ad6f07110e2e90a8e31-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17e60eb6a550ad6f07110e2e90a8e31-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><br \/>\nDynaDrive\u306e\u8996\u899a\u7684\u306a\u7279\u9577\u306e\u4e00\u3064\u3068\u3057\u3066\u3001\u76f4\u65b9\u4f53\u306e\u30c7\u30b6\u30a4\u30f3\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<br \/>\n\u76f4\u65b9\u4f53\u30c7\u30b6\u30a4\u30f3\u3092\u63a1\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u8a2d\u7f6e\u30b9\u30da\u30fc\u30b9\u306e\u7e2e\u5c0f\u3084\u652a\u62cc\u52b9\u7387\u304c\u6539\u5584\u3055\u308c\u307e\u3057\u305f\u3002DynaDrive S.U.B. \u306b\u306f\u3001\u8907\u6570\u679a\u306e\u30a4\u30f3\u30da\u30e9\u304c\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u679a\u6570\u3084\u8a2d\u7f6e\u9593\u9694\u306f\u5404\u30b5\u30a4\u30ba\u3067\u7570\u306a\u3063\u3066\u304a\u308a\u3001\u9ad8\u3044\u652a\u62cc\u52b9\u7387\u304c\u5f97\u3089\u308c\u3001\u304b\u306450 L\u304b\u30895,000 L\u307e\u3067\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u304c\u7dad\u6301\u3067\u304d\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13501\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17a00b8398128c9174613f1444c2843.jpg\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17a00b8398128c9174613f1444c2843.jpg 1280w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17a00b8398128c9174613f1444c2843-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17a00b8398128c9174613f1444c2843-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/d17a00b8398128c9174613f1444c2843-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><br \/>\n\u6b21\u306b\u3001\u652a\u62cc\u52b9\u7387\u3068\u30d9\u30c3\u30bb\u30eb\u5f62\u72b6\u306e\u95a2\u4fc2\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<br \/>\n\u652a\u62cc\u52b9\u7387\u306e\u89b3\u70b9\u3067\u3001\u6700\u3082\u52b9\u7387\u304c\u60aa\u3044\u306e\u306f\u4e0a\u8a18\u30b9\u30e9\u30a4\u30c9\u4e00\u756a\u5de6\u5074\u306b\u793a\u3057\u305f\u5186\u7b52\u5f62\u306e\u30ea\u30a2\u30af\u30bf\u30fc\u306e\u4e2d\u5fc3\u306b\u30a4\u30f3\u30da\u30e9\u3092\u8a2d\u7f6e\u3057\u305f\u30c7\u30b6\u30a4\u30f3\u3067\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u6e26\u6d41\u306e\u767a\u751f\u3084\u3001\u5358\u4e00\u65b9\u5411\u306e\u307f\u306e\u30d5\u30ed\u30fc\u3001\u652a\u62cc\u306b\u6642\u9593\u304c\u304b\u304b\u308b\u3068\u3044\u3063\u305f\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n<p>\u4e0a\u8a18\u30b9\u30e9\u30a4\u30c9\u5de6\u304b\u30892\u756a\u76ee\u306e\u30d1\u30bf\u30fc\u30f3\u304c\u5f53\u793e\u306e\u5f93\u6765\u578b\u306e\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3068\u540c\u69d8\u306e\u69cb\u9020\u3067\u3001\u30a4\u30f3\u30da\u30e9\u4f4d\u7f6e\u304c\u504f\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u6e26\u6d41\u3068\u652a\u62cc\u6642\u9593\u306f\u6539\u5584\u3055\u308c\u307e\u3059\u304c\u3001\u30d5\u30ed\u30fc\u304c\u5358\u4e00\u65b9\u5411\u3067\u3042\u308b\u70b9\u306f\u5909\u308f\u308a\u307e\u305b\u3093\u3002\u30b9\u30c6\u30f3\u30ec\u30b9\u306e\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3088\u304f\u4f7f\u7528\u3055\u308c\u308b\u30d0\u30c3\u30d5\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3053\u308c\u3089\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3067\u304d\u307e\u3059\u304c\u3001\u3055\u3089\u306b\u652a\u62cc\u52b9\u7387\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u3001DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u306f\u76f4\u65b9\u4f53\u3067\u30a4\u30f3\u30da\u30e9\u3092\u4e2d\u5fc3\u3067\u306f\u306a\u304f\u5c11\u3057\u5f8c\u65b9\u306b\u8a2d\u7f6e\u3057\u3001\u3053\u308c\u3089\u306e\u8ab2\u984c\u3092\u89e3\u6d88\u3057\u307e\u3057\u305f\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13502\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/db8ece5c425894136c200f853d02c5a2.jpg\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/db8ece5c425894136c200f853d02c5a2.jpg 1280w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/db8ece5c425894136c200f853d02c5a2-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/db8ece5c425894136c200f853d02c5a2-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/db8ece5c425894136c200f853d02c5a2-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><br \/>\nDynaDrive S.U.B.\u306e\u6db2\u4e2d\u901a\u6c17\u306b\u4f7f\u7528\u3059\u308b\u6539\u826f\u578b\u30ec\u30fc\u30b6\u30fc\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u30ec\u30fc\u30b6\u30fc\u3092\u7528\u3044\u3066\u7cbe\u5bc6\u306a\u30b5\u30a4\u30ba\u306e\u901a\u6c17\u5b54\u3092\u4f5c\u3063\u3066\u3044\u307e\u3059\u3002\u901a\u6c17\u5b54\u306e\u30b5\u30a4\u30ba\u3084\u6570\u306f\u3001\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u304c\u62c5\u4fdd\u3055\u308c\u308b\u3088\u3046\u3001DynaDirve S.U.B.\u306e\u30b5\u30a4\u30ba\u3054\u3068\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e0a\u8a18\u30b9\u30e9\u30a4\u30c9\u53f3\u306b\u3001\u30de\u30a4\u30af\u30ed\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\uff08\u30d5\u30ea\u30c3\u30c8\uff09\u3068\u5f93\u6765\u306e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3001DynaDrive S.U.B.\u3067\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u901a\u6c17\u91cf\u3068kLa\u5024\u306e\u95a2\u4fc2\u3092\u793a\u3057\u307e\u3059\u3002\u9752\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304c\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u307f\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u8d64\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304c\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u5f93\u6765\u306e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f75\u7528\u3057\u305f\u5834\u5408\u3001\u7dd1\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304cDynaDrive S.U.B.\u3067\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3067\u3059\u3002<\/p>\n<p>\u901a\u6c17\u91cf\u304c\u4f4e\u3044\u5834\u5408\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u9ad8\u3044kLa\u5024\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u6d41\u91cf\u306b\u9650\u308a\u304c\u3042\u308b\u305f\u3081\u3001\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u4f75\u7528\u3059\u308b\u5fc5\u8981\u304c\u51fa\u3066\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u4f75\u7528\u3057\u305f\u5834\u5408\u3067\u3082kLa\u5024\u306f40\u7a0b\u5ea6\u307e\u3067\u306b\u3068\u3069\u307e\u308a\u307e\u3059\u3002<br \/>\n\u4e00\u65b9\u3001DynaDrive S.U.B.\u3067\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u6c17\u4f53\u306e\u5c01\u5165\u91cf\u306b\u6bd4\u4f8b\u3057\u3066kLa\u5024\u3082\u4e0a\u6607\u3057\u3066\u3044\u304d\u300150\u3092\u8d85\u3048\u308bkLa\u5024\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u3001DynaDrive S.U.B.\u306e3\u3064\u306e\u7279\u9577\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>1\u3064\u76ee\u306e\u7279\u9577\u306f\u3001\u9ad8\u3044\u30bf\u30fc\u30f3\u30c0\u30a6\u30f3\u6bd4\u3068\u5c11\u306a\u3044\u6a5f\u5668\u53f0\u6570\u3067\u6d88\u8017\u54c1\uff08\u5ec3\u68c4\u7269\uff09\u306e\u524a\u6e1b\u3084\u62e1\u5927\u57f9\u990a\u306e\u5de5\u7a0b\u77ed\u7e2e\u306b\u3088\u308b\u52b4\u529b\uff08\u30aa\u30da\u30ec\u30fc\u30b7\u30e7\u30f3\u30b3\u30b9\u30c8\uff09\u3092\u524a\u6e1b\u3057\u30015,000 L\u307e\u3067\u306e\u57f9\u990a\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\u3002<br \/>\n2\u3064\u76ee\u306e\u7279\u9577\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u306a\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0\u3067\u3059\u3002\u30d9\u30c3\u30bb\u30eb\u524d\u65b9\u306e\u6249\u304c\u5b8c\u5168\u306b\u958b\u304f\u3088\u3046\u306b\u306a\u3063\u3066\u304a\u308a\u3001BPC\u306e\u53d6\u308a\u4ed8\u3051\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u9ad8\u3055\u306e\u3042\u308b3,000 L\u30015,000 L\u306b\u3064\u3044\u3066\u306f\u30ea\u30d5\u30c8\u6a5f\u69cb\u3092\u63a1\u7528\u3057\u3001BPC\u3084\u30c1\u30e5\u30fc\u30d6\u985e\u306e\u53d6\u308a\u4ed8\u3051\u306b\u3064\u3044\u3066\u3001\u9ad8\u6240\u3067\u306e\u4f5c\u696d\u304c\u4e0d\u8981\u306b\u306a\u308a\u307e\u3057\u305f\u3002<br \/>\n3\u3064\u76ee\u306e\u7279\u9577\u306f\u3001\u9ad8\u52b9\u7387\u3092\u5b9f\u73fe\u3059\u308b\u76f4\u65b9\u4f53\u30c7\u30b6\u30a4\u30f3\u3067\u9ad8\u3044\u9178\u7d20\u8981\u6c42\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u308b\u652a\u62cc\u6027\u80fd\u304a\u3088\u3073\u652a\u62cc\u52b9\u7387\u3092\u517c\u306d\u5099\u3048\u300150 L\u304b\u30895,000 L\u307e\u3067\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u304c\u53ef\u80fd\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305fDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u304a\u3088\u3073\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u88fd\u54c1\u306b\u95a2\u3059\u308b\u95a2\u9023\u8cc7\u6599\u306f\u3001\u4e0b\u8a18\u30ea\u30f3\u30af\u3088\u308a\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u88fd\u54c1\u95a2\u9023\u8cc7\u6599<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/single-use-docdl.html?CID=dynadrive_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u307e\u305f\u306f\u88fd\u9020\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u306e\u4f7f\u7528\u3001\u30d2\u30c8\u304a\u3088\u3073\u52d5\u7269\u3078\u306e\u76f4\u63a5\u7684\u306a\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thermo Scientific\u2122 DynaDrive\u2122 \u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09\u306f\u300150 L\u304b\u30895,000 L\u307e\u3067\u5e45\u5e83\u3044\u6db2\u91cf\u3067\u52d5\u7269\u7d30\u80de\u3092\u57f9\u990a\u3067\u304d\u308b\u5f53\u793e\u306e\u6700\u65b0\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3059\u3002 \u76f4\u65b9\u4f53\u306e\u30d0\u30a4<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":{"0":"post-13496","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-cell","7":"tag-cell-culture","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577\" \/>\n<meta property=\"og:description\" content=\"Thermo Scientific\u2122 DynaDrive\u2122 \u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09\u306f\u300150 L\u304b\u30895,000 L\u307e\u3067\u5e45\u5e83\u3044\u6db2\u91cf\u3067\u52d5\u7269\u7d30\u80de\u3092\u57f9\u990a\u3067\u304d\u308b\u5f53\u793e\u306e\u6700\u65b0\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3059\u3002 \u76f4\u65b9\u4f53\u306e\u30d0\u30a4\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-03-13T08:41:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-15T00:40:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577\",\"datePublished\":\"2023-03-13T08:41:04+00:00\",\"dateModified\":\"2023-11-15T00:40:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/\"},\"wordCount\":145,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/8c5e37eed51ac099a9625abf834af637.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/\",\"name\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/8c5e37eed51ac099a9625abf834af637.jpg\",\"datePublished\":\"2023-03-13T08:41:04+00:00\",\"dateModified\":\"2023-11-15T00:40:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/8c5e37eed51ac099a9625abf834af637.jpg\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/8c5e37eed51ac099a9625abf834af637.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/dynadrive_bpg_1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577","og_description":"Thermo Scientific\u2122 DynaDrive\u2122 \u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09\u306f\u300150 L\u304b\u30895,000 L\u307e\u3067\u5e45\u5e83\u3044\u6db2\u91cf\u3067\u52d5\u7269\u7d30\u80de\u3092\u57f9\u990a\u3067\u304d\u308b\u5f53\u793e\u306e\u6700\u65b0\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3059\u3002 \u76f4\u65b9\u4f53\u306e\u30d0\u30a4","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-03-13T08:41:04+00:00","article_modified_time":"2023-11-15T00:40:27+00:00","og_image":[{"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg","type":"","width":"","height":""}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577","datePublished":"2023-03-13T08:41:04+00:00","dateModified":"2023-11-15T00:40:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/"},"wordCount":145,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/","name":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg","datePublished":"2023-03-13T08:41:04+00:00","dateModified":"2023-11-15T00:40:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/8c5e37eed51ac099a9625abf834af637.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/dynadrive_bpg_1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01DynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc(S.U.B.)\u306e3\u3064\u306e\u7279\u9577"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":64,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":13496,"position":0},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":13496,"position":1},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23457,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25063\/","url_meta":{"origin":13496,"position":2},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u8840\u6e05\uff08FBS\uff09\u3068\u6297\u751f\u7269\u8cea\u306e\u30dd\u30a4\u30f3\u30c8\uff5e\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e5","author":"LatB Staff","date":"2025\u5e7410\u670822\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3059\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-culture-basic-bid-ts-mbr-25063_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23098,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url_meta":{"origin":13496,"position":3},"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","author":"LatB Staff","date":"2025\u5e7410\u67082\u65e5","format":false,"excerpt":"\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20129,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25016\/","url_meta":{"origin":13496,"position":4},"title":"\u3010\u7b2c2\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce","author":"LatB Staff","date":"2026\u5e744\u670828\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u64cd\u4f5c\u3067\u5f79\u7acb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u56de\u53ce\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0f\u80de\u4f53\u30b5\u30a4\u30ba","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/251d14a615127ecd8e0dac1beeb32074.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":13496,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13496"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13496\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13496"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}