{"id":13636,"date":"2023-03-28T11:20:48","date_gmt":"2023-03-28T02:20:48","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13636"},"modified":"2025-04-15T16:09:54","modified_gmt":"2025-04-15T07:09:54","slug":"qpcr-software-gsd-ts-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/","title":{"rendered":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2"},"content":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u591a\u304f\u306f96\u30a6\u30a7\u30eb\u30d6\u30ed\u30c3\u30af\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u3044\u305f\u3060\u304f\u3054\u8cea\u554f\u306b\u300c1\u3064\u306e\u5b9f\u9a13\u309296\u30a6\u30a7\u30eb\u306e\u4e2d\u3067\u5b8c\u7d50\u3055\u305b\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u306e\u304b\uff1f\u300d\u3068\u3044\u3046\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5fc5\u305a\u3057\u30821\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u3067\u5b8c\u7d50\u3055\u305b\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u5f0a\u793e\u3067\u306f\u8907\u6570\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u306b\u307e\u305f\u304c\u3063\u305f\u30c7\u30fc\u30bf\u3092\u89e3\u6790\u3067\u304d\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u300cExpressionSuite Software\u300d\u3092\u7121\u511f\u3067\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u3069\u306a\u305f\u3067\u3082\u7c21\u5358\u306b\u8907\u6570\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3067\u304d\u307e\u3059\u3002\u4eca\u56de\u306e\u8a18\u4e8b\u3067\u306fExpressionSuite Software\u3092\u4f7f\u3046\u305f\u3081\u306e\u6761\u4ef6\u3084\u4f7f\u7528\u65b9\u6cd5\u3001\u5f97\u3089\u308c\u308b\u30c7\u30fc\u30bf\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u0394\u0394C<sub>T<\/sub>\uff08Comparative C<sub>T<\/sub>\uff09\u6cd5\u3067\u89e3\u6790\u3055\u308c\u3066\u3044\u308b\u65b9<br \/>\n\u30fb\u30b5\u30f3\u30d7\u30eb\u3084\u6e2c\u5b9a\u3059\u308b\u907a\u4f1d\u5b50\u306e\u6570\u304c\u591a\u3044\u65b9<br \/>\n\u30fbApplied Bisystems\u2122 TaqMan\u2122 Array plate\/card\u3092\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u65b9<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/software-downloads\/expressionsuite-software.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_software_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\"><b>ExpressionSuite Software\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u30da\u30fc\u30b8<\/b><\/a><\/p>\n<h2>ExpressionSuite Software\u3092\u4f7f\u7528\u3059\u308b\u305f\u3081\u306e\u6761\u4ef6<\/h2>\n<p>ExpressionSuite Software\u3067\u89e3\u6790\u3059\u308b\u305f\u3081\u306b\u306f\u30e9\u30f3\u30c7\u30fc\u30bf\u304c\u4e0b\u8a18\u306e3\u3064\u306e\u6761\u4ef6\u3092\u6e80\u305f\u3059\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ol>\n<li>\u0394\u0394C<sub>T<\/sub>\u6cd5\u3067\u306e\u6e2c\u5b9a\u3067\u3042\u308b\u3053\u3068\n<ul>\n<li>\u0394\u0394C<sub>T<\/sub>\u6cd5\u306e\u30c7\u30fc\u30bf\u3092\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u3059\u3002\u30e9\u30f3\u30c7\u30fc\u30bf\u306eExperiment type\u3092\u0394\u0394C<sub>T<\/sub>\u306b\u6307\u5b9a\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u5168\u3066\u306e\u5b9f\u9a13\u30c7\u30fc\u30bf\u304c\u540c\u4e00\u6761\u4ef6\u3067\u30e9\u30f3\u3055\u308c\u3066\u3044\u308b\u3053\u3068\n<ul>\n<li>\u6e2c\u5b9a\u88c5\u7f6e\u3084\u30e9\u30f3\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u540c\u3058\u3067\u3042\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7570\u306a\u308b\u6761\u4ef6\u3067\u30e9\u30f3\u3057\u305f\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u5171\u901a\u306e\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u907a\u4f1d\u5b50\u3092\u30e9\u30f3\u3054\u3068\u306b\u6e2c\u5b9a\u3057\u3066\u3044\u308b\u3053\u3068\n<ul>\n<li>\u8868\u73fe\u304c\u308f\u304b\u308a\u3065\u3089\u3044\u306e\u3067\u5177\u4f53\u7684\u306a\u4f8b\u3067\u3054\u8aac\u660e\u3057\u307e\u3059\u300296\u7a2e\u985e\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u309296\u30b5\u30f3\u30d7\u30eb\u306b\u3064\u3044\u3066\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u30012\u3064\u306e\u30ec\u30a4\u30a2\u30a6\u30c8\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u30021\u3064\u76ee\u306f\u30bf\u30fc\u30b2\u30c3\u30c8\u3054\u3068\u306b\u307e\u3068\u3081\u308b\u65b9\u6cd5\u3067\u30011\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u306796\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3057\u30661\u3064\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u30022\u3064\u76ee\u306f\u30b5\u30f3\u30d7\u30eb\u3054\u3068\u306b\u307e\u3068\u3081\u308b\u65b9\u6cd5\u3067\u30011\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u30671\u3064\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3057\u306696\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u5168\u3066\u6e2c\u5b9a\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002ExpressionSuite Software\u3067\u89e3\u6790\u3067\u304d\u308b\u306e\u306f\u5f8c\u8005\u306e\u30b5\u30f3\u30d7\u30eb\u3054\u3068\u306b\u307e\u3068\u3081\u305f\u30c7\u30fc\u30bf\u3067\u3059\u3002\u3053\u308c\u306f\u6e2c\u5b9a\u3057\u305f\u30bf\u30a4\u30df\u30f3\u30b0\u306e\u30b5\u30f3\u30d7\u30eb\u72b6\u614b\u3092\u53cd\u6620\u3057\u3066\u3044\u308b\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u6e2c\u5b9a\u5024\u3067\u88dc\u6b63\u3059\u308b\u3079\u304d\u3068\u3044\u3046\u8003\u3048\u305f\u65b9\u306b\u3088\u308b\u3082\u306e\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u540c\u3058\u30d7\u30ec\u30fc\u30c8\u5185\u3067\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u304c\u6e2c\u5b9a\u3055\u308c\u308b\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p>\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u88c5\u7f6e\u3068\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u30d0\u30fc\u30b7\u30e7\u30f3\u306f\u4e0b\u8a18\u306e\u8868\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_13675\" style=\"width: 550px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13675\" class=\"wp-image-13675 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\" alt=\"ExpressionSuite Software\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u88c5\u7f6e\u3068\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u30d0\u30fc\u30b8\u30e7\u30f3\" width=\"540\" height=\"358\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png 540w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2-300x199.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2-96x65.png 96w\" sizes=\"auto, (max-width: 540px) 100vw, 540px\" \/><p id=\"caption-attachment-13675\" class=\"wp-caption-text\">\u88681 ExpressionSuite Software\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u88c5\u7f6e\u3068\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u30d0\u30fc\u30b8\u30e7\u30f3<\/p><\/div>\n<p>PC\u306e\u8981\u4ef6\u306f\u4e0b\u8a183\u70b9\u3067\u3059\u3002<\/p>\n<ul>\n<li>Windows\u2122 7, SP1 or Windows\u2122 10<\/li>\n<li>Pentium 4 or compatible, with minimum 2GB of RAM and 20 GB of hard drive capacity<\/li>\n<li>Minimum monitor resolution of 1280&#215;1024<\/li>\n<\/ul>\n<h2>ExpressionSuite Software\u3067\u306e\u89e3\u6790\u65b9\u6cd5<\/h2>\n<p>ExpressionSuite Software\u3067\u306e\u89e3\u6790\u306b\u306f\u30d0\u30a4\u30aa\u30a4\u30f3\u30d5\u30a9\u30de\u30c6\u30a3\u30af\u30b9\u306e\u77e5\u8b58\u306f\u4e0d\u8981\u3067\u3059\u3002\u30c7\u30fc\u30bf\u3092\u53d6\u308a\u8fbc\u307f\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u3092\u8a2d\u5b9a\u3059\u308b\u3060\u3051\u3067\u7c21\u5358\u306b\u89e3\u6790\u3067\u304d\u307e\u3059\u3002\u5177\u4f53\u7684\u306a\u624b\u9806\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n<ol>\n<li style=\"text-align: left\">\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u7acb\u3061\u4e0a\u3052\u3068Study\u306e\u4f5c\u6210\n<ul>\n<li>\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7acb\u3061\u4e0a\u3052Create Study\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002Study name\u3092\u5165\u529b\u3057\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13676\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/cbf5b9f60da99bf791c0aa12a770f429-1.png\" alt=\"\" width=\"604\" height=\"92\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/cbf5b9f60da99bf791c0aa12a770f429-1.png 604w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/cbf5b9f60da99bf791c0aa12a770f429-1-300x46.png 300w\" sizes=\"auto, (max-width: 604px) 100vw, 604px\" \/><\/li>\n<\/ul>\n<\/li>\n<li>\u30c7\u30fc\u30bf\u306e\u53d6\u308a\u8fbc\u307f\n<ul>\n<li>\u753b\u9762\u5de6\u5074\u30e1\u30cb\u30e5\u30fcSetup\u5185\u306eExperiments\u30e1\u30cb\u30e5\u30fc\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n<li>Import\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u5bfe\u8c61\u306e\u30e9\u30f3\u306e\u751f\u30c7\u30fc\u30bf\uff08\u62e1\u5f35\u5b50.eds\uff09\u3092\u53d6\u308a\u8fbc\u307f\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13698\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-03.png\" alt=\"\" width=\"1440\" height=\"863\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-03.png 1440w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-03-300x180.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-03-1024x614.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-03-768x460.png 768w\" sizes=\"auto, (max-width: 1440px) 100vw, 1440px\" \/><\/li>\n<\/ul>\n<\/li>\n<li>\u00a0\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u6307\u5b9a\n<ul>\n<li>Targets and controls\u753b\u9762\u3092\u958b\u304d\u307e\u3059\u3002<\/li>\n<li>Target\u3092\u9078\u629e\u3057\u305f\u72b6\u614b\u3067\u300cAssign Type\u300d\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002\u300cEndogenous Control\u300d\u306b\u6307\u5b9a\u3057\u305f\u3082\u306e\u304c\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3068\u3057\u3066\u88dc\u6b63\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/li>\n<li>\u300cCandidate control\u300d\u306b\u6307\u5b9a\u3059\u308b\u3068\u753b\u9762\u4e0b\u90e8\u306b\u5404\u30b5\u30f3\u30d7\u30eb\u306eCt\u5024\u3092\u30d7\u30ed\u30c3\u30c8\u3057\u305f\u30b0\u30e9\u30d5\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u9593\u306eCt\u5024\u306e\u5dee\u3092\u8996\u899a\u7684\u306b\u3068\u3089\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306b\u4fbf\u5229\u306a\u30b0\u30e9\u30d5\u3067\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13699\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-04.png\" alt=\"\" width=\"1422\" height=\"844\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-04.png 1422w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-04-300x178.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-04-1024x608.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-04-768x456.png 768w\" sizes=\"auto, (max-width: 1422px) 100vw, 1422px\" \/><\/li>\n<\/ul>\n<\/li>\n<li>\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b5\u30f3\u30d7\u30eb\u306e\u6307\u5b9a\n<ul>\n<li>\u753b\u9762\u4e0a\u90e8\u306b\u3042\u308bAnalysis Settings\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001Relative Quantification Settings\u30bf\u30d6\u3092\u958b\u304d\u307e\u3059\u3002\u300cReference Sample\u300d\u306b\u6307\u5b9a\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u304c\u76f8\u5bfe\u6bd4\u3092\u6c42\u3081\u308b\u305f\u3081\u306e\u57fa\u6e96\u3068\u306a\u308a\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13695\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-05.png\" alt=\"\" width=\"1226\" height=\"864\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-05.png 1226w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-05-300x211.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-05-1024x722.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-05-768x541.png 768w\" sizes=\"auto, (max-width: 1226px) 100vw, 1226px\" \/><\/li>\n<\/ul>\n<\/li>\n<li>\u89e3\u6790\u306e\u5b9f\u65bd\n<ul>\n<li>\u4e0a\u90e8\u306b\u3042\u308b\u7dd1\u8272\u306e\u4e09\u89d2\u30de\u30fc\u30af\u300cAnalyze\u300d\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u89e3\u6790\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2>\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u4f8b<\/h2>\n<p>\u89e3\u6790\u7d50\u679c\u3067\u306f\u76f8\u5bfe\u6bd4\u306e\u30b0\u30e9\u30d5\u4ee5\u5916\u306b\u3082\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u304c\u4f5c\u6210\u3055\u308c\u3001\u30c7\u30fc\u30bf\u3092\u53ef\u8996\u5316\u3067\u304d\u307e\u3059\u3002<br \/>\n\u300cGene Expression\u300d\u753b\u9762\u3067\u306f\u76f8\u5bfe\u6bd4\u306e\u30b0\u30e9\u30d5\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13696\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-06.png\" alt=\"\" width=\"1286\" height=\"789\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-06.png 1286w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-06-300x184.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-06-1024x628.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-06-768x471.png 768w\" sizes=\"auto, (max-width: 1286px) 100vw, 1286px\" \/><\/p>\n<p>\u300cHeat Map\u300d\u3067\u306f\u30d2\u30fc\u30c8\u30de\u30c3\u30d7\u3067\u30c7\u30fc\u30bf\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u767a\u73fe\u30d1\u30bf\u30fc\u30f3\u304c\u4f3c\u3066\u3044\u308b\u30b5\u30f3\u30d7\u30eb\u3084\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u3092\u898b\u3064\u3051\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13697\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-07.png\" alt=\"\" width=\"1309\" height=\"781\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-07.png 1309w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-07-300x179.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-07-1024x611.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/qpcr-software-gsd-ts-1-07-768x458.png 768w\" sizes=\"auto, (max-width: 1309px) 100vw, 1309px\" \/><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u0394\u0394C<sub>T<\/sub>\u306e\u30c7\u30fc\u30bf\u3092\u8907\u6570\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u96e3\u3057\u3044\u8a2d\u5b9a\u306f\u4e0d\u8981\u3067\u76f4\u611f\u7684\u306b\u64cd\u4f5c\u3067\u304d\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<br \/>\nExpressionSuite Software\u306f\u4e0b\u8a18\u30da\u30fc\u30b8\u304b\u3089\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/software-downloads\/expressionsuite-software.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_software_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p><b>\u305d\u306e\u4ed6\u95a2\u9023\u8cc7\u6599<\/b><br \/>\n\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u3053\u306e1\u518a\u3067\u308f\u304b\u308b\u300c\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u300d\u3092\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_software_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u3067\u306e\u300c\u56f0\u3063\u305f\u300d\u3092\u89e3\u6c7a\u3059\u308b\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9\u3082\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u4f75\u305b\u3066\u3054\u3089\u3093\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_software_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Windows is a trademark of Microsoft Corporation.<br \/>\n\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u591a\u304f\u306f96\u30a6\u30a7\u30eb\u30d6\u30ed\u30c3\u30af\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u3044\u305f\u3060\u304f\u3054\u8cea\u554f\u306b\u300c1\u3064\u306e\u5b9f\u9a13\u309296\u30a6\u30a7\u30eb\u306e\u4e2d\u3067\u5b8c\u7d50\u3055\u305b\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u306e\u304b\uff1f\u300d\u3068\u3044\u3046\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5fc5\u305a\u3057\u30821\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u3067\u5b8c\u7d50\u3055\u305b\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":{"0":"post-13636","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-mol-bio","7":"tag-qpcr","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\" \/>\n<meta property=\"og:description\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u591a\u304f\u306f96\u30a6\u30a7\u30eb\u30d6\u30ed\u30c3\u30af\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u3044\u305f\u3060\u304f\u3054\u8cea\u554f\u306b\u300c1\u3064\u306e\u5b9f\u9a13\u309296\u30a6\u30a7\u30eb\u306e\u4e2d\u3067\u5b8c\u7d50\u3055\u305b\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u306e\u304b\uff1f\u300d\u3068\u3044\u3046\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5fc5\u305a\u3057\u30821\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u3067\u5b8c\u7d50\u3055\u305b\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-03-28T02:20:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T07:09:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"540\" \/>\n\t<meta property=\"og:image:height\" content=\"358\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\",\"datePublished\":\"2023-03-28T02:20:48+00:00\",\"dateModified\":\"2025-04-15T07:09:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/\"},\"wordCount\":113,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/\",\"name\":\"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\",\"datePublished\":\"2023-03-28T02:20:48+00:00\",\"dateModified\":\"2025-04-15T07:09:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/03\\\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-software-gsd-ts-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/","og_locale":"ja_JP","og_type":"article","og_title":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","og_description":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306e\u591a\u304f\u306f96\u30a6\u30a7\u30eb\u30d6\u30ed\u30c3\u30af\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3088\u304f\u3044\u305f\u3060\u304f\u3054\u8cea\u554f\u306b\u300c1\u3064\u306e\u5b9f\u9a13\u309296\u30a6\u30a7\u30eb\u306e\u4e2d\u3067\u5b8c\u7d50\u3055\u305b\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u306e\u304b\uff1f\u300d\u3068\u3044\u3046\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5fc5\u305a\u3057\u30821\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u3067\u5b8c\u7d50\u3055\u305b\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-03-28T02:20:48+00:00","article_modified_time":"2025-04-15T07:09:54+00:00","og_image":[{"width":540,"height":358,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","datePublished":"2023-03-28T02:20:48+00:00","dateModified":"2025-04-15T07:09:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/"},"wordCount":113,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/","name":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png","datePublished":"2023-03-28T02:20:48+00:00","dateModified":"2025-04-15T07:09:54+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/03\/29d3bc99193cb0b837fb8cc53f050ae5-2.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-software-gsd-ts-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"qPCR\u89e3\u6790\u3092\u7c21\u5358\u306b\uff01\u8907\u6570\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u89e3\u6790\u3059\u308b\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13636"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13636\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13636"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13636"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13636"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}